1. Steri DSe Thank you for purchasing this SteriDesign SteriBox Disinfectant System Please read these instructions and save them for future use Product Features e Your new SteriDesign SteriBox product is effective against a number of pathogens including MRSA C difficile and E Coli It can be used for small handheld devices including land line phones mobile phones stethoscopes pagers two way radios remote controls and other personal items such as ID badges keys writing utensils wallets etc e This product features a powerful Ultraviolet UV C illumination system that is safe and effective when used in accordance with these instructions e This product will automatically shut off after each cycle The cycle time is factory set to 10 minutes Simply lift the product cover insert your items and close the product cover to initiate another disinfection cycle e This product will automatically turn off once the disinfection cycle is complete e Your SteriBox Product comes with the following unique features o Cutouts in the lid of the unit to allow corded items to be cleaned o An outlet on the side of the unit to allow mobile phones or other small devices to be charged during the disinfection cycle o An accessory adapter for the rear unit that allows it to be used with Hil Rom Wall mounting systems o Asmall shelf designed into the unit that provides space for your mobile phone keys ID badges or other smaller items o A quick ch
2. ange bulb feature that allows you to easily change your bulbs after 1 year of use o A built in auto on off switch that turns the unit on off automatically when the cover is open or closed SteriBox Installation and Use Instruction 1 Using two small screws mount the unit within reach of a power outlet The two screw keyholes in the back of the unit allows the unit to be slipped over these screws to properly secure the unit onto the mounting surface A separate plastic adapter plate is included to allow the unit to be used with certain Hil Rom wall mounting systems 2 Insure the SteriBox product is plugged into a working outlet Open the top cover of the SteriBox by applying a slight amount of downward pressure on the cover s tab as you pull it open 3 Insert your device into the unit insuring that the cord if it is a corded device is placed into one of the cutout holes in the top cover 4 Close the cover until you hear a slight click which will automatically start the disinfection cycle The ultraviolet bulbs will turn on and start to clean your device automatically 5 The SteriBox will turn off automatically after 10 minutes and your device can be removed If at any time you want to remove your device prior to the disinfection cycle completion open the cover and the unit will turn off automatically 6 There is aconvenient shelf inside the unit allowing you to also clean your mobile phone or other small items and an
3. gn LLC will at its option repair or replace defective parts of this product at no charge to the customer subject to the following limitations This limited warranty does not include refund to the customer for postage freight handling insurance or delivery fees This warranty does not cover damage defect or failure caused by or resulting from accident external destruction alteration modification abuse misuse or misapplication of this product This warranty does not cover damage to the product resulting from return shipping or handling The use of shipping insurance is recommended to help protect your product Return Authorization is required for all returns To obtain a Return Authorization please contact your SteriDesign distributor If during the first year of ownership this product fails to operate properly it should be returned as specified to your SteriDesign distributor Note SteriDesign recommends using a quality surge suppressor on all electronics equipment Voltage variations and spikes can damage electronic components in any system A quality suppressor can eliminate the vast majority of failures attributed to surges and may be purchased at electronics stores Due to ongoing improvements actual product may have slight variations from the product described in this manual Made in China SteriDesign LLC Copyright 2013 SteriDesign LLC All rights reserved IMSDSB111014
4. ing cycle e Never use the SteriDesign product on pets or people e The SteriDesign product is not intended for use on food e Do not look into the UV C light source during operation e The SteriDesign product should not be used to disinfect any part of your body including your hands or feet e Care should be taken when changing the UV C bulbs which contain a small amount of mercury that can cause injury if inhaled or ingested For more information on clean up and disposal see www lampsrecycle org FCC Information This SteriDesign product complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation e Changes or modifications to the SteriDesign product will void the user s authority to operate equipment as well as the Warranty for the device changed or modified ONE YEAR LIMITED WARRANTY ATTENTION FOR WARRANTY CLAIMS WITHIN THE ONE YEAR LIMITED WARRANTY PERIOD PLEASE CONTACT YOUR DISTRIBUTOR FOR REPAIR OR REPLACEMENT SteriDesign warrants this product to be free from defects in material and workmanship for a period of one year from the date of the original retail purchase from SteriDesign or an authorized SteriDesign distributor Proof of purchase is required for all warranty claims During the limited warranty period SteriDesi
5. lbs can be purchased from the supplier or distributor whom you purchased your SteriDesign product o Unplug the SteriBox and remove from the wall Turn upside down to locate the two sliding covers o Slide each cover off and locate the harness that connects the bulb apparatus to the unit Carefully pull the harness apart o Slide the bulb assembly out and dispose of this properly More information on how to dispose of the bulb assembly can be found at www lampsrecycle org o Slide the replacement bulb assembly into the unit carefully and connect the harness securely to the connector of the SteriBox unit o Slide the cover back over the bulb area and test your unit to insure the bulbs are turning on If not check the connections once again Reinstall the SteriBox according to the instructions Warnings and Precautions e To prevent fire or shock hazard do not expose the SteriDesign product to rain or excessive moisture e There are no serviceable parts other than the replacement of the light bulbs in the unit Refer all servicing to qualified service personnel Replacement light bulbs can be purchased from your original supplier or distributor Warnings and Precautions continued e The SteriDesign product should not be exposed to dripping or splashing No objects filled with liquids such as vases should be placed on or near the SteriDesign product e Never stare directly at the bulbs of the SteriDesign product during the clean
6. outlet on the side to allow your small electronic devices to be charged during the cleaning cycle Technical Specifications e Size L263mm x W205mm x H82mm 10 5 x 8 1 x 3 6 e Weight 900g 1 98 Ibs e UV Bulb U Type cold cathode e UV C Lamp 2 0W Diameter 0 5 x 140mm 1 Piece e UV C Lamp 4 0W Dia 0 5 x 190mm 1 Piece SteriBox replacement bulb sets may be ordered and purchased through your authorized SteriDesign distributor e Frequency range 185nm e Tube life 1 year NOTE Bulb must be changed once per year to insure effective disinfection levels are achieved e Working temperature 0 50 C 32F 122F e UV strength 5000UW cm e Ozone density 20 01lppm lt 0 05ppm e Power source AC120V 50 60 Hz e Length of Power Cord 2m 3A TROUBLESHOOTING e The SteriDesign disinfecting device will not turn on o Be sure the SteriDesign product is plugged into a properly operating outlet o Ifitis plugged into an outlet strip or other power extension device insure the outlet strip is operating properly o Insure that the bulbs are properly installed and connected to the power harness firmly o The cover must be closed completely to insure proper operation Insure that nothing is blocking the cover to allow it to close completely o Contact your authorized SteriDesign distributor if you have further questions e It has been one year since the installation of my SteriBox and I need to change the bulbs o Replacement bu