Home
Wireless Thermo Recorder User`s Manual
Contents
1. If the shield has a defect or tear the waterproof Temperature and Humidity measurements capacity is lost as the shield is very thin Inspect it before operation ENDLESS Upon reaching storage capacity the oldest data is overwritten and recording continues Recording Mode 1 ONETIME Upon reaching storage capacity recording will automatically stop LCD Display Items Current Readings Recording Status Battery Life Warning Messages Unit of Measurement Lithium Battery _S14250 SAFT x 1 L type Large Capacity Battery Adaptor Kit RTR 500B1 x 1 2 Power External Power Adaptor Kit RTR 500A1 sold separately Battery Life 3 About 10 months L type About 4 years TR 3310 Temp Humidity Sensor for RTR 503 42 700 26 Communication Interfaces Short Range Wireless Optical Communication Radio Standard Specifications ETSI EN 300 220 869 7 to 870MHz Wireless Transmission Range About 150m 500ft if unobstructed and direct When downloading one Remote Unit at full storage capacity Communication time Wireless communication about 2 minutes 4 Optical communication about 160 seconds Water Resistance IP67 immersion proof IP64 IP64 Splash Proof 5 H62mm x W 47mm x D19mm L Type D 50mm with Large Capacity Battery Pack Pimensions excluding protrusions antenna length 23mm Weight About 56g including 1 lithium battery L Type About 109g
2. C or higher not only will battery life be shortened but the unit itself and its parts will deteriorate more rapidly Please do not use in such environments for prolonged periods of time Memory FULL If recording under the ONE empleo TIME MODE when the number LL rm m ES of data readings reaches the ALII specified capacity recording will stop and FULL will be displayed intermittently with the current temperature E Data Capacity Estimate of time until FULL is displayed o c A we Ta TJ TN Wireless Communication This will appear when data is being sent via wireless communication to the Base Unit Measurement Range Exceeded for RTR 502 The temperature display blinks when the temperature goes below 60 C or above 155 C Notices about this User s Manual In order to properly use this product please carefully read this manual before using T amp D Corporation accepts no responsibility for any malfunction of and or trouble with this product or with your computer that is caused by the improper handling of this product and will deem such trouble or malfunction as falling outside the conditions for free repair outlined in the attached warranty All rights of this User s Manual belong to T amp D Corporation It is prohibited to use duplicate and or arrange a part or whole of this User s Manual without the
3. Period 1 year from date of purchase Date of Purchase Customer s name Address Phone No Distributor s name Address Phone No Object of Repair Main Unit excluding sensors and any other options Method of Repair Send in for Repair Provisions for Free Repair If the Unit does not work properly despite the fact that the customer used it properly and in line with the manual the Unit shall be repaired free of charge through the distributor which sold the Unit If the customer requests free repair because of trouble within the warranty period bring or send the Unit along with the warranty to the distributor If you have moved after purchasing or there are difficulties contacting the distributor from which you purchased the Unit please contact T amp D directly for service Free repair is not available in the following cases even though it is within the warranty period 1 Trouble or damage was caused by careless operation natural disaster fire public pollution or use of a power source other than specified 2 If repair adjustment disassembly or modification of the Unit has been carried out by a person other than a T amp D authorized engineer 3 Trouble or damage was caused by transportation movement or dropping of the Unit after purchase 4 Failure to submit the Warranty or failure to fill in all items required in the Warranty The Warranty cannot be reissued This Warranty only promises customers free
4. and recording will RTR 503 8 000 data readings x 2 ch continue and battery power consumed EX Recording Interval of 30 seconds x Data readings of 8000 240 000 seconds Do not take apart repair or modify the main unit about 2 days and 18 hours It may cause fire electrocution or damage Ask the shop where you purchased the products or T amp D Corporation to carry out any repairs Check A If any smoke or strange smells are emitted from the unit immediately cease using it Continued use may cause fire electrocution or damage If this appears all data that was stored l pan a g j A Do not use any batteries other than those that are recommended ul Lo in the Logger will have been erased It may cause fire or damage IL This will be displayed under the Q If water or a foreign object enters the case immediately cease using it following conditions The first time a battery was inserted after purchase If the battery is replaced after having been taken out for a long period A We are not responsible for any malfunction or trouble caused by the use of our product or by any problem caused by the malfunction of our unit Please be fully aware of this before using our product ifi i This product has been designed for private or industrial use only Prod ucts Specifications A It is not for use in situations where strict safety precautions are necessary such as in connection with medical equipment whether directly or indirectly Unit RTR 501
5. repair within the period and conditions clarified in this Warranty Therefore the customer s legal rights will not be limited by this Warranty For further information on repair and other service questions after the termination of the warranty period contact your distributor
6. 9 Avg 0 3 C J 5 RH Aone 4 Sec in agitated water Cracks may develop in the unit casing if it comes into contact with hazardous NOT Re Ngee tee i substances such as oil products Measurement Accuracy Avg 0 5 C at 40 to 20 C 80 to 110 C Possible Temperature Measurement Range 60 to 155 C we f il p CIS 3 T i g a A Sensor Temperature Resistance 70 to 180 C If the unit is being used in an environment where there is a possibility of oil spraying or Avg 1 0 C A Temp Measurement Accuracy splashing T amp D advises protecting the unit by placing it in a polyethylene bag at 60 to 40 C 110 to 155 C at 25 C and 50 RH Avg 0 3 C at 20 to 80 C i Avg 0 5 C at 40 to 20 C 80 to 110 C ee Display 0 1 C 0 1 C 0 1 C 1 RH Avg 1 0 C at 60 to 40 C 110 to 155 C A Notes about Sensors Water Resistance Recording Intervals Select from 15 choices 1 2 5 10 15 20 and 30 seconds 1 2 5 10 15 20 30 and 60 minutes The fluoropolymer coated section is waterproof TR 51 06 the standard Sensor for RTR 502 8 000 Readi Other sections are immersion proof IPX4 Do no fold the sensor tip section or expose it to a strong impact This may cause trouble or break the f o 8 eadings rg Materials Thermistor wire Storage Capacity 16 000 Readings 16 000 Readings One reading is a set of data which includes Fluoropolymer coated Electrical Wire The sensor and the cable are shielded by Tefl on
7. ENYN Wireless Thermo Recorder User s Manual RTR 501 RTR 502 RTR 503 CE T amp D Corporation http www tandd com Shimadachi 817 1 Matsumoto Nagano JAPAN 390 0852 Fax 81 263 40 3152 Copyright T amp D Corporation All rights reserved This is printed using recycled paper 2011 05 16504590010 2nd Edition 1 Part Names RTR 501 RTR 502 503 Antenna Easy wwe LCD Display Optical Communication Area Sensor Jack What is a Wireless Thermo Recorder These products are data loggers designed to measure and record temperature and humidity with built in wireless communication capability No longer it is necessary to manually gather the data loggers Rather via our special radio communication function data download settings analysis and the saving of data can all be done via a wireless Base Unit connected to your PC RTR 502 RTR 503 With External Temperature With External Temperature Sensor TR 5106 Included Humidity Sensor TR 3310 Included RTR 501 With Internal Temperature Sensor Common Items Included Lithium Battery LS14250 x 1 inserted into a tube Strap x 1 User s Manual Warranty x 1 We have prepared an array of Remote Units to meet your needs RTR 501 502 503 These Remote Units cannot be used without a Base Unit Base Units must be purchased separately 2 Connecting
8. RTR 501L RTR 502 RTR 502L RTR 503 RTR 503L TR 5106 A Do not drop or expose the unit to strong impact Measurement Items Temperature Temperature Temperature Humidity Fluoropolymer Coated Sensor for RTR 502 i i i i Number of Channels 1 Channel 1 Channel 1 Channel 1 Channel poly S Do not put your fingers or foreign matter into the sensor connection Unit of Measurement C F C F C F 600 26 Q Battery terminals may provide insufficient contact due to age or vibration Measurement Range 40 to 80 C 60 to 155 C 0to 55 C 10 to 95 RH T 7 7 Please be careful not to lose data due to insufficient contact mo External Temp Sensor External Temp and Humidity Sensor j Battery life depends on the measurement environment communication frequency gensor Internal Temp Sensor TR 5106 TR 3310 D hia h Z recording interval and battery quality _ _ 4 Thermal Time Constant 15 minutes Approx 30 Sec in air S Sier POR S Avoid using the lithium batteries LS 14250 for long periods at temperatures over 60 C L Type 25 minutes Approx 4 Sec in agitated water Unit mm The battery life may be signifi cantly decreased 5 7 Cable Length 0 6m O h i ith the i f Sofi Sensor Res e Time 4 z About 7 min 90 nse perate the units with the latest version of Software ld ei utz mins tesponse pela Time a A The latest version software can be downloaded from our home page fe a m A rox ec In alr ry i ri Ei Fy P ANG M S a 90
9. a Sensor Make sure that the sensor or sensor adaptor is inserted until you hear a click sound LCD Display When being used in very cold or hot environments the display may become difficult to read This is not a malfunction Recording Status ON Displayed during recording or when FULL of data BLINKING Waiting for programmed start Not ON Recording has been stopped Battery Life Warning Displayed when time to change the battery Measurement and Message Display Area Current measurements or operational messages will appear here Unit of Measurement For details about the message area see the back of this manual 3 Installing the Batter When a battery is installed temperature measurement will start at the factory default settings or the previously set ones Factory Default Settings Recording Mode Endless Recording Interval 10 minutes Recording Start Immediate Start 1 Remove the screws and open the case 2 Insert the tubed battery into the case as shown in the diagram below 3 Check the rubber packing for any cuts or scratches and replace the cover as it was when opened Rubber Packing 1 jel If you are using a commercially purchased battery please place it in the tube Battery Inserted into tube Make sure to use the proper size and type of screwdriver A Phillips 1 head screwdriver is best If using a CR2 lithium batte
10. ature Humidity sensor cable cannot be extended When the sensor is not used put it in the attached plastic bag with a drying agent and keep it in cool dark place at 5 C to 25 C and 30 RH or less The replacement period for the standard sensor is 1 year Replace it when 1 year has passed after opening the bag A Compliance Information Radio EMC and Safety Regulations A Important Notice Wireless products cannot be used in countries other than where those products have been approved for use according to that country s wireless regulations T amp D Corporation shall in no manner whatsoever take responsibility for the usage of these products nor be liable in any manner for legal consequences stemming from the usage of these wireless products in unapproved areas This device complies with technical specifications required under EN 301 489 with battery and AC Adaptor EN 300 220 and EN 60950 1 S Do not use or store the unit in places such as listed below It may cause electrocution fire or damage to the unit or to your computer Areas exposed to direct sunlight Areas exposed to water or high pressure water flow Areas exposed to organic solvents and corrosive gas Areas exposed to strong magnetic fields Areas exposed to static electricity Areas exposed to fire or overheating Areas exposed to excessive dust or smoke Wireless Thermo Recorders Warranty _IRTR 501 _ RTR 502 _ IRTR 503 Guarantee
11. cal damage or death A Denotes an important warning or caution S Denotes a forbidden action These entries are actions that if taken may lead to A CAUTION physical injury or damage to persons or things Q Denotes an action that must be taken ADANGER Q Store all batteries sensors and Thermo Recorder units out of the reach of children It is dangerous to swallow batteries A Please be careful when using in overly hot or cold environments touching the units may cause burns or frostbite Recordi P P atd 1 second 30 second 15 minutes 60 minutes To prevent any loss or damage to our customers other Explanation of Warning Symbols T people and or property and to ensure the proper use of our RTR 501 about 4 hours and about 5 days and about 166 days and about 1 year and products we ask that before using our product you carefully RTR 502 26 minutes 13 hours 16 hours 10 months about 2 hors and about 2 days and about 83 days and read understand and follow the safety rules and precautions A DANGER RTR 503 13 mi utes iane ahours about 11 months No Sensor for our products as outlined below RTR 501 RTR 502 16 000 data readings x 1ch mre c Displayed when a sensor has not EX Recording Interval of 30 seconds x Data readings of 16 000 480 000 seconds ae Ss been connected or the wire has been about 5 days and 13 hours broken Measurement
12. indicator may remain on for a short time This is due to a special characteristic of the battery Note that the longer the battery has been in storage the longer the amount of time from 10 minutes to about 1 hour the BAT indicator will remain on If during that time the Base Unit is used to get the Current Status of the Remote Unit the remaining battery level will show that the battery level is low e Please store the Lithium Battery LS14250 in a place that is 20 C or less 4 Battery Replacement Mark When the replacement mark appears try to replace the battery with a new one as soon as possible 1 When it is time for the battery to be on ie he replaced the Zg mark will appear a a o e 2 If you do not change the battery D 4 and continue using the unit the Cli i C temperature display will intermittently rice display bAtt After this point the downloading of data can no longer be done via wireless communication Without changing the battery and attempting to use optical communication to download data the communication may be broken and if so all recorded data may be lost If the battery is changed at this point recording will continue after it has been changed 3 If the battery is further left unchanged the display will automatically shut off roecere If at this time the battery is changed LHE L CHEC will appear in the displa
13. permission of T amp D Corporation TANDD T amp D and the logo of T amp D Corporation are all registered property of T amp D Corporation Specifications design and other contents outlined in this manual are subject to change without notice We are not responsible for any malfunction or trouble caused by the use of our product or by any problem caused by the use of measurement results of our unit Please be fully aware of this before using our product On screen messages in this manual may vary slightly from the actual messages Please notify the shop where you purchased this product or T amp D Corporation of any mistakes errors or unclear explanations in this manual T amp D Corporation accepts no responsibility for any damage or loss of income caused by the use of our product This product has been designed for private or industrial use only It is not for use in situations where strict safety precautions are necessary such as in connection with medical equipment whether directly or indirectly This User s Manual cannot be reissued so please keep it in a safe place Please carefully read this User s Manual and Warranty Safety Precautions and Instructions Please carefully observe the following safety measures when using our product Explanation of Picture Symbols These entries are actions that absolutely under no circumstance should be taken The taking of such an action may cause serious personal physi
14. ry the tube is not necessary If dirt or scratches are present on the rubber packing water resistance will be reduced Be sure to completely close the cover Make sure not to over tighten the screws Appropriate torque 20N cm 30N cm 2Kgf cm 3Kgf cm Notes about Battery Installation e f a new battery has been installed and recording does not immediately start nothing appears in the display or any other such malfunction please remove the battery check to make sure plus and minus are correct and re insert the battery e After inserting the battery for the first time nothing may appear or occur for about 10 seconds this is not a malfunction e If plus and minus are mistaken or if the battery terminals and are shorted the recorded data that is stored in the logger will be lost e Make sure no water or foreign objects get inside the case e To maintain water resistibility when changing batteries we suggest also changing the rubber packing and the drying agent About Lithium Batteries e Lithium batteries CR2 sold in stores may also be used but if you are using in an environment below 20 C above 60 C or in a situation such as transportation where continued vibration is likely to occur we strongly suggest the purchase and use of the our lithium battery LS14250 Please purchase optional part 11P2 e When using an LS14250 type lithium battery even though a new battery has been inserted the BAT
15. ture Resistance 10 to 60 C Measurement Accuracy Temperature Avg 0 3 C At 25 C 50 RH Humidity Avg 5 RH At 25 C 50 RH Replacement Period 1 year under normal operational conditions Conditions for Use Under conditions without condensation water leakage or effects from corrosive gas or organic solvents Water Resistance None Materials Temperature Humidity Sensor Polypropylene Resin Vinyl Chloride Coated Electrical Wire Q The RTR 501 502 are devices to measure temperature The RTR 503 is a device to measure temperature and humidity Do not use these units for any other purpose ZA CAUTION cases The case was closed with dust hair etc on the rubber packing or in the groove for the packing The rubber packing was damaged In this case please purchase the optional maintenance set The unit suffered from significant temperature change while wet especially if the temperature change was from high to low A Pay attention to water leakage or foreign objects entering into the unit case as in the following Insert the sensor tip of least 5cm or more to obtain on accurate temperture measurement Only use the sensor within the sensor heat durability range TR 3310 the standard temperature and humidity sensor for RTR 503 Use the sensor only within the measurable temperature and humidity range Temperature 0 C to 55 C and Humidity 10 to 95 RH The Temper
16. with Large Capacity Battery Pack 30 to 80 C Unit temp resistance and measurement range is 40 to 80 C Unit Temp Resistance y pa R P P but wireless communication cannot occur in an environment of less than 30 C Others In order to download data via wireless communication it is necessary to purchase Base Unit 1 When using RTR 500GSM RTR 500NW or RTR 500AW as a Base Unit only ENDLESS can be selected When using an RTR 500 as a Base Unit possible to select from either ENDLESS or ONETIME 2 When using RTR 500B1 it is necessary to purchase Lithium Battery LS26500 For details contact your local authorized representative 3 The stated battery life is for when it is used in an environment of 25 C and recorded data is downloaded at a rate of once a day or Monitoring Current Readings occurs at a rate of once every 10 minutes Battery life depends on measurement environment recording interval and battery performance 4 The same amount of time will be necessary for each added Repeater 5 The stated water resistance rating is for when the sensor is connected to the unit However this does not include the sensor areas for the RTR 503 503L models Not for continued immersion re ar ie 12 Q SHJ 2 chit ORO 63 4 Unit mm Cable Length 0 7m Possible Temperature Measurement Range 0 to 55 C Possible Humidity Measurement Range 10 to 95 RH Sensor Tempera
17. y after which recording will begin again using the previously set recording conditions All of the recorded data up until that point will be erased 5 Communicating with a PC To register a data logger as a Remote Unit connect the data logger to the computer For details about how to connect the unit see the Introductory Guide that comes with the Base Unit or see the application s Help Communication errors may occur in environments where temperatures are very high or very low If the battery level of the data logger is very low communication may be broken or may not be possible A Estimating Lithium Battery Life A new battery should last about 10 months if it is used in an environment of normal temperature and recorded data is downloaded at a rate of once a day or Monitoring Current Readings occurs as a rate of once every 10 minutes About using in Low and High Temperature environments Use in Low temperature environments will result in a shortening of the battery life 20 C one half of life compared to normal temperatures 30 C one third of life compared to normal temperatures In normal temperature environments the GL mark may not appear but under low temperatures this mark may appear and communication may be impossible Use in High temperature environments will also causer battery life to be shortened 60 C one half of life compared to normal temperatures In environments of 60