1. ALL Power cable DMX data cable DMX512 2 RDM Communicator Note DMX controller has to be disconnected from the fixture when the RDM communicator is operated ArcPad 48 Integral RDM Communicator Power data cable Junction box Power DMX data cable DMX512 RDM protocol ArcPad 48 Integral RGBW 3 5 DMX 512 connection To build a DMX chain 1 Connect the DMX output of the controller directly with the DMX input of the first fixture in the DMX chain 2 Connectthe DMX output of the first fixture in the DMX chain with the DMX input of the next fixture 3 Always connect the DMX output with the input of the next fixture until all fixtures are connected Do not overload the link Max 32 fixtures may be connected on a DMX link Caution Terminate the output of the last fixture with a 120 Ohm resistor wired betwen data and data in order to ensure the proper transmission on the data link 3 6 Master slave connection To build a master slave chain Connect the DMX output of the master fixture in the data chain with the DMX input of the first slave Always connect output with the input of the next slave until all slaves are connected up to 32 fixtures Caution It is necessary to terminate the input of the master fixture and the output of the last slave with a 120 Ohm resistor in order to ensure the proper transmission on the data link 3 7 Stand alone operation The fixtures o
2. OOOO X 4 Press the ENTER button 5 Use the UP DOWN buttons to select yES option 6 Press the ENTER button Note If you do not want to continue in software update you have to switch off and on the fixture to escape from this menu 3 Disconnect the RDM communicator from the fixture 4 Connect serial port of your PC with a DMX input of the fixture if you using the flash cable RS232 DMX If you use the Robe Universal Interface 1 Disconnect the fixture from other fixtures in a DMX link 2 Connect the Robe Universal Interface to the fixture and switch this fixture to the update mode 1 Run the RDM Network and select menu item Remote LED Display 2 Use the UP DOWN buttons to find SPEC menu 3 Press the ENTER button 4 Use the UP DOWN buttons to select uPd item Tox 5 Press the ENTER button Use the UP DOWN buttons to select yES option 7 Press the ENTER button gi 20 ArcPad 48 Integral RGBW Note If you do not want to continue in software update you have to switch off and on the fixture to escape from this menu 8 After switching the fixture to the update mode cancel the RDM Network program Run the Software Uploader program Select desired COM and then click on the Connect button Note we recommend to cancel all running programs before starting the Software Uploader ColorSpot 700EAT Software Uploader v3 0 Select COM if the E serial port is used DN Sele
3. 48 Integral has been powered on in the EcO mode since the counter was last reset In order to reset this counter to O you have to press and hold the UP and DOWN buttons and at the same time press the ENTER button DM In DMX values Select this function to read DMX values of each channel received by the fixture tEMP Fixture Temperatures Select this menu to read the temperatures of the fixture Cur t the current temperature of the fixture inside Hi tE the menu item shows the max temperatures of the fixture inside since the ArcPad 48 Integral has been fabricated 16 ArcPad 48 Integral RGBW rSEt the menu item shows the maximum temperatures of the fixture inside since the counter was last reset In order to reset this counter to O you have to press and hold the UP and DOWN buttons and at the same time press the ENTER button Note The ambient temperature should not exceed 40 C The temperatures can be displayed in either C or F units see option tEM U in the menu Pers VErS Software Versions Select this function to read the software version of the fixture processor 6 3 Personality pe Er 5 Use this menu to modify the ArcPad 48 Integraloperating behaviour DM Pr DMX preset Select this menu item to set a desired DMX mode Please refer to the chapter DMX protocol for detail description of each DMX mode DiSP Display adjusting This function allows you to change the d
4. RDM communicator to the fixture and from the menu Control select the Remote LED display item The fixture s control display with the four control buttons will appear on the screen of the RDM communicator SS Ses SS L 1D 5253 0024000A Remote LED Display nn 1 moos 9000 O ER ON OFF H The control buttons have the following functions Y ESCAPE button leaves menu without saving changes lt l ENTER button enters menu confirms adjusted values and leaves menu UP and Y DOWN buttons move between menu items on the same level sets values Robe universal Interface Click with the right button of the mouse on the fixture or a manufacturer icon and select the Remote LED display option from the menu list as shown below 14 ArcPad 48 Integral RGBW Elle Scan Tools Options View MES lo E 1 DMX Network QA E Me fe ES GetysetParameters 3 B i Bom Network 1 device Device UID 52 53 00 2d 00 a3 root device 3 1 DIVX512 Current Personality Mode 3 gt EN Identify Device of y DMY Start Address 13 Patch DMX Addresses Collect Parameters View Sensor Values Remote LED Display Device Label Noname Set Parameter Device Reset warm y Lamp State A Lamp On Mode T Display Invert off E T Display Level 2555 Pan Inver
5. base serve for mounting on the non flammable flat surface ArcPad 48 Integral RGBW a 9y Q 8 9 la e Ensure that the structure to which you are attaching the fixture is secure Caution Overhead installation requires experience Fixtures may cause severe injuries when crashing down If you have doubts concerning the safety of a possible installation do not install the device and consult installation with an expert 3 2 Connection to the mains Fixtures must be installed by a qualified electrician in accordance with all national and local electrical and construction codes and regulation The ArcPad 48 Integral is equiped with with a 5 cored power data cable The 3 cores serve for the power supply and next 2 shielded cores are intended for DMX connection The power cores are coloured according to the following table TI CI This device falls under class one and must be grounded The data cores DMX are coloured according to the table The power data cable is connected to a junction box as shown on the picture below ArcPad 48 Integral RGBW Screws Cover Fixture Screws Power data cable Power data cable Insert flat tip screwdriver Junction box when inserting wire Junction box Power L Live N Neutral PE Earth Signal Signal GND Signal ground ArcPad 48 Integ
6. button and use the UP DOWN buttons to set value press the ENTER button to confirm it 6 5 Test sequences ESE tE Use this menu to run demo test sequences without an external controller which will show you some possibilities of using the ArcPad 48 Integral 6 6 Stand alone setting ELO ALI The fixtures on a data link are not connected to the controller but can execute pre set programs which can be different for every fixture Stand alone operation can be applied to the single fixture or to multiple fixtures operating synchronously Synchronous operation of multiple fixtures requires that they must be connected on a data link and one of them is set as a master MASt and the rest as the slaves SLA Up to 32 fixtures can be connected in a master slave chain Only one fixture can be set as the master Note Disconnect the fixtures from the DMX controller before master slave operating otherwise data collisions can occur and the fixtures will not work properly See the chapters Stand alone operation and Master slave connection Auto Automatic playback This function allows you to select the program which will be played after switching the fixture on Selected program will be played continuously in a loop 1 Use the UP DOWN buttons to find St AL menu Press the ENTER button Use the UP DOWN buttons to select Auto item Press the ENTER button Use the UP DOWN buttons to select desired prog
7. master MASt or slave SLA Press the ENTER button to confirm the choice Dy 012 910 Note After switching on the ArcPad 48 Integralwill automatically detect whether DMX 512 data is received or not If there is no data received at the DMX input the display will start to flash with actually set address 6 2 Fixture information I C INFO Use this menu to read useful information about the fixture status To display desired information 1 Use the UP DOWN buttons to find the InFo menu 2 Press the ENTER button 3 Use the UP DOWN buttons to select the required menu item 4 Press the ENTER button to confirm the choice Po ti Power On Time Use the menu item to read the number of operation hours for each LEDs operating mode FuLL Max light output from the fixture totL the function shows the total number of the operation hours in the FuLL mode since the ArcPad 48 Integral has been fabricated rESEt the function shows the number of the operation hours that the ArcPad 48 Integral has been powered on in the FuLL mode since the counter was last reset In order to reset this counter to O you have to press and hold the UP and DOWN buttons and at the same time press the ENTER button EcO Economical mode totL the function shows the total number of the operation hours in the EcO mode since the ArcPad 48 Integral has been fabricated rESEt the function shows the number of the operation hours that the ArcPad
8. ANOLIS ArcPad 48 Integral RGBW ArcPad 48 Integral EPS RGBW USER MANUAL Version 1 6 ArcPad 48 Integral RGBW Table of contents 1 Safety a A ass 3 2 Fixture exterior VIEW iia GR 5 Stalin isis aa na Ak a An KR aa ala A a aaa diel phe a eaten eee 5 3 1 1 Mounting th tixturessss iss a a ad oki Naast spa a 5 3 2 Connection to the MAINS cinta A AA AA aa ai 6 3 3 Installation of the Darn do Suicida aria 8 IA S tting NO CONTO tr a mesi 9 SO DMX 512 CONNE CON A ee eee ti eter mild deta 10 36 Master slaVe CONMCCtION ii ata 10 3 1 Standsalone Operation dus and ais Ba dad lak DF a astan nana 10 4 ArcPad 48 Integral RGBCW DMX protocol cccccccessssecssssecessseececsssaececsssaececeseasececsesaeeecsesaeeeeseaeeeeseaaeeeesesaeeeeneas 11 5sContrallmen Map sr ar a aa 12 A AR 14 6 T EXTUTS ASS A AAA a Ati 15 OZ FIXUS IN O MON A AA AA lute A a iaeia 16 6 3 Person a id nel au seeds 17 EME A aaDaR th bet ha eel AE A E E 18 6 5 Test SEQUENCES kk A va cies i lak ar Ra cts Sue aan a a A ER aaa eekan 18 6 6 Stand alone settings kA colada dd 18 627 SpeCial FUN TT 19 Fe ROM aka a a kasti kfk Rai EA A A A kan ks 21 BU ECFOMANG INFOFMATION Messa ass ra ra a kg E EE 22 9 Technical Specifications ao 23 10 Cleaning andimaintenance sas A innata ka eee eR ae ee eh Res 26 IA oT 1 0 it A A A RO A E A A EE ia tte den 26 111 ArcPad 48 Integral EPS secre td erento Tae 26 ArcPad 48 Integral RGBW FOR Y
9. During the operation the housing becomes hot up to 80 C Refer servicing to qualified service personnel This fixture falls under protection class Therefore this fixture has to be connected to a mains socket outlet with a protective earthing connection Do not connect this fixture to a dimmer pack LED light emission Risk of eye injury Do not look straight at the fixture s LEDs during operation The intense light beam may damage your eyes Keep compustible materials at least 20 cm away from the fixture If the fixture has been exposed to drastic temperature fluctuation e g after transportation do not switch it on immediately The arising condensation water might damage your device Leave the device switched off until it has reached room temperature Avoid brute force when installing or operating the fixture The fixture was designed for outdoor use This fixture must not be used for underwater installation 3 ArcPad 48 Integral RGBW When choosing the installation spot please make sure that the fixture is not exposed to extreme heat or dust Avoid using the unit in locations subject to possible impacts The fixture body never must be covered with cloth or other materials Only operate the fixture after having checked that the housing is firmly closed and all screws are tightly fastened Make sure that the area below the installation place is blocked when rigging derigging or servicing the fixture Do not block the
10. OUR OWN SAFETY PLEASE READ THIS USER MANUAL CAREFULLY BEFORE POWERING OR INSTALLING YOUR ArcPad 48 Integral Save it for future reference This device has left our premises in absolutely perfect condition In order to maintain this condition and to ensure a safe operation itis absolutely necessary for the user to follow the safety instructions and warning notes written in this manual The manufacturer will not accept liability for any resulting damages caused by the non observance of this manual or any unauthorized modification to the device Please consider that damages caused by manual modifications to the device are not subject to warranty 1 Safety instructions DANGEROUS VOLTAGE CONSTITUTING A RISK OF ELECTRIC SHOCK IS PRESENT WITHIN THIS UNIT Make sure that the available voltage is not higher than stated on the rear panel of the fixture This fixture should be operated only from the type of power source indicated on the marking label If you are not sure of the type of power supplied consult your authorized distributor or local power company Always disconnect the fixture from AC power before cleaning removing or installing the fuses or any part Do not overload wall outlets and extension cords as this can result in fire or electric shock Make sure that the power data cord is never crimped or damaged by sharp edges Check the fixture and the power data cord from time to time Do not install the unit near naked flames
11. colour the bLuE and repeat steps 6 7 for this colour gt CON DNAWN LoAd Load of LEDs The menu allows to choose 2 different operating modes for fixture FuLL Maximum light output EcO The light output is decreased by 25 In Po Init effect positions Use this function to set all effects to the desired positions to which they will move after switching the fixture on if DMX is not being received Note If DMX mode 1 is selected only values set at items MACr macro and dinr dimmer will be accepted dF SE Default Settings The menu item sets all fixture parameters to the default factory values 17 ArcPad 48 Integral RGBW 6 4 Manual mode NO_N VIVIDOS Use this menu for control the fixture without connected DMX console PrE C Preset effects control Select this menu to call up preset positions of the channel effects Man C Manual effect control Select this menu to control all channels via buttons of the control board To control fixture channels 1 Use the UP DOWN buttons to find Man C menu 2 Press the ENTER button 3 Use the UP DOWN buttons to select desired effect channel List of control channels rEd1 red LEDs saturations GrE1 green LEDs saturations bLu1 blue LEDs saturations Whit white LEDs saturations MACr colour macros Stro a strobe shutter dimr a dimmer F dim a fine dimmer 4 Press the ENTER
12. ct DreamBox1 A if the USB port is Ranna used If the connection is OK click on the Start Uploading button to start uploading It will take several minutes to perform software update If the option Incremental Update is not checked all processors will be updated including processors with the same software version If you wish to update only the latest versions of processors check the Incremental Update box Avoid interrupting the process Update status is being displayed in the Info Box window When the update is finished the line with the text The fixture is successfully updated will appear in this window and the fixture will reset with the new software 7 RDM This fixture is ready for RDM operation RDM Remote Device Management is a bi directional communications protocol for use in DMX512 control systems it is the new open standard for DMX512 device configuration and status monitoring The RDM protocol allows data packets to be inserted into a DMX512 data stream without adversely affecting existing non RDM equipment By using a special Start Code and by complying with the timing specifications for DMX512 the RDM protocol allows a console or dedicated RDM controller to send commands to and receive messages from specific moving lights RDM allows explicit commands to be sent to a device and responses to be received from it The list of commands for ArcPad 48 Integralis the following ArcPad 48 Integra
13. ep 3 Prog step 4 Prog step 5 Program length Continous repeating Prog step 1 Slave 1 Prog step 1 Prog step 2 Prog step 3 Prog step 1 Prog step 2 Pipg step 31 Program lengh fo Slave 2 Prog step 1 Prog step 2 Prog step 3 Prog step 4 Prog step 5 1 i i Program length Note Disconnect the fixtures from the DMX controller before master slave operating otherwise data collisions can occur and the fixtures will not work properly 10 ArcPad 48 Integral RGBW 4 ArcPad 48 Integral RGBCW DMX protocol CEN 1 1 Mode Channel BEBE Value Type of control Red LEDs 0 255 Red LEDs saturation control 0 100 proportional 2 22 Green LEDs 0 255 Green LEDs saturation control 0 100 proportional 31313 Blue LEDs 0 255 Blue LEDs saturation control 0 100 proportional White LEDs 0 255 White LEDs saturation control 0 100 proportional Colour macros 255 values No function for DMX mode 4 White for DMX mode 1 step 1 15 White tones cool gt warm proportional 16 Blue Blue full Red Green White 0 step 17 55 Red 0 Green gt up Blue full White 0 proportional 56 Light Blue Red 0 Green full Blue full White 0 step 57 95 Red 0 Green full Blue gt down White 0 proportional 96 Green Red 0 Green full Blue 0 White 0 step 97 134 Red gt up Green full Blue 0 White 0 proportional 135 Yellow green Red full Green full Blue 0 White 0 step 136 174 Red full Green gt d
14. front objective LEDs with any object when the fixture is under operation The fixture becomes very hot during operation Allow the fixture to cool approximately 30 minutes prior to manipulate with it Operate the fixture only after having familiarized with its functions Do not permit operation by persons not qualified for operating the fixture Most damages are the result of unprofessional operation Do not attempt to dismantle or modify the unit Please consider that unauthorized modifications on the fixture are forbidden due to safety reasons Please use the original packaging if the fixture is to be transported If this device will be operated in any way different to the one described in this manual the product may suffer damages and the guarantee becomes void Furthermore any other operation may lead to dangers like short circuit burns electric shock etc ArcPad 48 Integral RGBW 2 Fixture exterior view 1 Lens array 2 Radiator 3 Base 4 Power data cord 3 Installation 3 1 Mounting the fixture The ArcPad 48 Integral can be arranged in any position orientation The ArcPpad 48 Integral s radiator with LEDs is mounted on an adjustable bracket for tilt adjustment into many positions Two slots 8 5mm wide in the fixture
15. gram steps value 1 68 This value should be set before start Programming e g if you want to create program with 10 steps set P End 10 rEd1 a red LEDs saturation 0 255 GrE1 a green LEDs saturation 0 255 bLu1 a blue LEDs saturation 0 255 Whi1 Whi4 a white LEDs saturation 0 255 MACr colour macros 0 255 Stro a strobe shutter 0 255 dimr a dimmer 0 255 F dim a fine dimmer 0 255 F tim a fade time 0 25 5 seconds S tim step time value 0 25 5 seconds COPY this item duplicates the current prog step to the next prog step The item P End is increased automatically 6 Use the UP DOWN buttons to set a DMX value of the channel and then press the ENTER button 7 Use the UP DOWN buttons to select next channel and press the ENTER button 8 After having set all channels in the current program step press the MODE button to go by one menu level back and select another program step 6 7 Special functions LOL rdML Code This menu item shows the first part of the RDM identification code rd MH Code This menu item shows the second part of the RDM identification code Ad Effect Adjustment The menu allows calibration of each LEDs array dMH DMX Values The menu item enables to control all LEDs before calibrating each LEDs array CAL U Calibrating unit The menu serves for fine current calibration of LED
16. isplay settings d On this function allows you to keep the display on or to turn off automatically 2 minutes after last pressing any button on the control panel d Int select this function to adjust the display intensity 30 min 100 max turn select this function to turn the display by 180 tEM U Temperature Unit Use this menu in order to display the fixture temperatures in desired units C or F bALA Balance Use this menu item to enable On or disable Off the white balance which is set in the White colour balance menu below f this function is set off the ArcPad 48 Integral will use maximum values 255 of saturation for red green and blue colour This function has to be set on before adjusting a white balance C bAL White Colour Balance The menu gives access to the setting of the white balance To set white colour balance Use a DMX controller or the Man C menu to set all LEDs on max saturation Use the UP DOWN buttons to find the Pers menu Press the ENTER button Use the UP DOWN buttons to select the C bAL menu Press the ENTER button and the rEd item will appear on the display Press the ENTER button and use the UP DOWN buttons to set new max value for the red LEDs Press the ENTER button to confirm the choice Use the UP DOWN buttons to select next colour the GrEn Repeat steps 6 7 for this channel 10 Use the UP DOWN buttons to select the last
17. itial lumen output in hours Electronics e Control USITT DMX 512 RDM e DMX protocol modes 4 2 3 4 8 control channels e Operations modes DMX Stand alone Master Slave e Manual control of all effects via RDM communicator e 3 user editable programs each up to 68 steps Strobe e Strobe effect with variable speed max 20 flashes per second e Pre programmed random strobe pulse effects Dimmer e Smooth 16 bit dimming from 0 100 Connection e Power data cable LI9YCHY Cable 3xAWG16 1x 2xAWG24 Shielded and Jacketed e junction box 23 ArcPad 48 Integral RGBW Rigging e Via two slots in the fixture base Temperatures e Maximum ambient temperature 40 C e Maximum housing temperature 80 C Dimensions mm ArcPad 48 integral 170 83 min 196 max 69 3 Y 147 2 24 ArcPad 48 Integral RGBW Junction box Weight 3kg Protection factor e IP 67 fixture IP66 junction box Included items e 1x ArcPad 48 Integral e 1 x Junction box No 99012672 e 1x User manual e 1x Gasket of cable grommet M20 PF P N 1305 1388 Optional accessories e 1x Barn doors module in silver colour No 10980090 e Eggcrate top hat module without lenses No 10980091 e Flash cable RS232 DMX No 13050624 Note By reason of
18. l RGBW DEVICE INFO SUPPORTED PARAMETERS SOFTWARE VERSION LABEL DMX START ADDRESS IDENTIFY DEVICE DEVICE MODEL DESCRIPTION MANUFACTURER LABEL DEVICE LABEL SENSOR DEFINITION SENSOR VALUE DISPLAY LEVEL DEVICE RESET DMX PERSONALITY DMX PERSONALITY DESCRIPTION STATUS MESSAGES STATUS ID DESCRIPTION DEVICE HOURS Please see the Robe Universal Interface user manual for detail description of RDM operation 8 Error and information messages t M Er Temperature measuring error The message informs you that the LED module temperature sensor is defective MA Er Master error The fixture is set as a master and DMX console is connected to the fixture 22 ArcPad 48 Integral RGBW 9 Technical specifications Power supply e Electronic auto ranging e Input voltage 100 240V AC 50 60 Hz e Fuse T2 5AH e Power consumption Power Max power consumption Typical power consumption Ambient mode All LED channels at full 2 LED Channels at full Temperature Full mode 60W 60W 25 C Eco mode 40W 40W Optic 8 Effects e Light source 48 Luxeon Rebel LEDs RGBW e Available optical systems 12 25 45 and 45 x 15 e RGBW colour mixing e Built in colour macros e Adjustable strobe sequences e White colour balance adjusting eLumen maintenance Channels Power L70 One LED Full mode 90 000 Two LED Full mode 85 000 Three LED Full mode 85 000 All LED Full mode 85 000 L7 70 maintenance of in
19. n a data link are not connected to the controller but can execute pre set programs which can be different for every fixture To set the program to be played see the Stand alone setting menu St AL Stand alone operation can be applied to the single fixture or to multiple fixtures operating synchronously Synchronous operation of multiple fixtures requires that they must be connected on a data link and one of them is set as a master master mode and the rest as the slaves slave mode To set the fixture as the master or slave see the Fixture Address menu A001 Only one fixture can be set as the master The master fixture starts simultaneous program start in the other slave fixtures All fixtures have a definite synchronized starting point when playing back their programs The number of running program is the same in all slaves and depends on the master s choice menu St AL Every fixture runs its program repeatedly starting the program step No 1 when requested by the master Example If the slave fixture has a shorter program length it will continuously repeat its program until the master fixture finishes its own program and restarts its program running slave 1 prog step 3 will not be finished If the slave fixture has a longer program length it will restart at prog step 1 before it completes all its prog steps slave 2 prog step 5 will not be played see the picture bellow Master Prog step 1 Prog step 2 Prog st
20. own Blue 0 White 0 proportional 175 Red Red full Green 0 Blue 0 White 0 step 176 214 Red full Green 0 Blue gt up White 0 proportional 215 Magenta Red full Green 0 Blue full White 0 step 216 254 Red gt down Green 0 Blue full White 0 proportional 255 Blue Red 0 Green 0 Blue full White 0 step Shutter Strobe 0 31 Shutter closed step 32 63 Shutter open step 64 95 Strobe effect from slow to fast proportional 96 127 Shutter open step 128 143 Opening pulses in sequences slow gt fast proportional 144 159 Closing pulses in sequences fast gt slow proportional 160 191 Shutter open step 192 223 Random strobe effects from slow to fast proportional 224 255 Shutter open step Dimmer 0 255 Dimmer intensity from 0 to 100 proportional Dimmer fine 0 255 Fine dimmer intensity from low to high proportional White LEDs lit proportionally when Red Green Blue LEDs are saturated together 11 ArcPad 48 Integral RGBW 5 Control menu map Default settings Bold A CC few IA CCSS AS A SLA F dim rsEt o poo feo pp 1C1 Mod 1 feas ee e Mod 4 30 60 100 turn oc F On Off GrEn 12 ArcPad 48 Integral RGBW TL INS EIN uLL EcO rE 01 rE 03 di 01 di 06 ArcPad 48 Integral RGBW Menu Level 1 Menu Level 2 Menu Level 3 Menu Level 4 Menu Level 5 Menu Level 6 ooo poo poo de SPEC rdML rdMH 6 Fixture menu RDM communicator Connect the
21. ral RGBW 3 3 Installation of the barn doors You can install the barn doors to better define illuminated surface To install the barn door module 1 Disconnect the fixture from the mains 2 Putthetop edge of the barn doors module into the second groove on the top side of the radiator detail A and the bottom edge into the second groove on the bottom side of the radiator and tighten four locking screws M2 to secure this barn doors module on the radiator barn doors Lens module Radiator Locking screws Insert barn doors module into the second groove Radiator Lens module Radiator Barn doors module Lock the barn doors module with the screws Never close the barn doors during fixture operation ArcPad 48 Integral RGBW 3 4 Setting and control For setting DMX address selecting DMX mode and for another settings you need either Robe Universal Interface or the RDM Communicator Please see the Robe Universal Interface or RDM Communicator user manuals to get more information about this products The way how to connect these interfaces to the DMX data link is figured below NOTE never connect the RDM communicator and the The Robe Universal Interface to the fixture at the same time 1 Robe Universal Interface Control PC USB cable Power data cable Robe Universal Interface Junction box DMX console
22. ram Press the ENTER button to confirm the choice NDA pin 18 ArcPad 48 Integral RGBW PLAY Playing program By enter to this menu a complete overview of all programs is offered from which the program to be run can be selected 1 Usethe UP DOWN buttons to find St AL menu 2 Pressthe ENTER button 3 Use the UP DOWN buttons to select desired program 4 Press the ENTER button The selected program runs in a loop Edit Editing a program The fixture offers 3 freely editable programs EPG 1 EPG 3 each up to 68 steps Every program step includes a fade time the time taken by the step s channel status to reach the desired level and a step time the total time occupied by the step in the program E g If F tim 5 second and S tim 20 second effects will go to the desired position during 5 seconds and after that they will stay in this position for 15 seconds before going to the next prog step 1 1 Use the UP DOWN buttons to find St AL menu and press the ENTER button 2 Use the UP DOWN buttons to select Edit menu and press the ENTER button 3 Use the UP DOWN buttons to select a program you want to edit PrG 1 PrG 3 and press ENTER button 4 Use the UP DOWN buttons to select a desired program step St 01 St 68 and press ENTER button 5 Use the UP DOWN buttons to select a channel you want to edit and press the ENTER button List of editable items P End a total number of the pro
23. s during fixture burn in at a factory Users should not change the setting uPd M Updating mode The menu item allows you to update software in the fixture via either serial or USB port of PC 19 ArcPad 48 Integral RGBW The following are required in order to update software PC running Windows 95 98 2000 XP or Linux DMX Software Uploader Flash cable RS232 DMX No 13050624 if you want to use a serial port of PC Robe Universal Interface if you want to use an USB port of PC Note1 Software update should execute a qualified person If you lack qualification do not attempt the update yourself and ask for help your ROBE distributor Note 2 DMX address programs 1 3 and all items in the menu PErS will be set to their default values To update software in the fixture I Installation of the DMX Software Uploader 1 DMX Software Uploader program is available from theAnolis web site at WWW anolis cz 2 Make a new directory e g Anolis Uploader on your hard disk and download the software into it 3 Unpack the program from the archive ll Fixture software updating If you use the RDM Communicator 1 Disconnect the fixture from other fixtures in a DMX link 2 Connect the RDM communicator to the fixture and switch this fixture to the update mode 1 Use the UP DOWN buttons to find SPEC menu 2 Press the ENTER button 3 Usethe UP DOWN buttons to select uPd item A ID 5253 0024000A Remote LED Display UPd
24. t Tilt Invert A Ready The Remote LED Display window will appear Now you can fullly control the fixture using the UP Down Enter Escape and Reset buttons RDM network 10 12 Elle Scan Tools Options View Help cor EN DMX Network QA E le Mee H a Get Set Parameters i t B 2 Bom Network 1 device Device UID 52 53 00 2d 00 33 root device 3 52 a3 17 DMX512 Current Personality modes y 2 Identify Device off y 1 DMX Start Address 13 2 Device Label Noname T Device Reset warm y 7 Remote LED Display D Ready 6 1 Fixture Address cored 1 LIO 1 Use this menu to set the DMX address of the fixture or set the fixture as a Master Slave dM Ad DMX addressing Select this submenu to set a DMX start address 15 ArcPad 48 Integral RGBW To set a DMX address 1 Use the UP DOWN buttons to find A001 menu Press the ENTER button Use the UP DOWN buttons to select desired start address Press the ENTER button to confirm the choice 291 0 MA SL Master slave addressing Select this submenu to set the fixture as a master or slave Option d AbL deactivates master slave setting To set a fixture as a master or slave 1 Use the UP DOWN buttons to find A001 menu Press the ENTER button Use the UP DOWN buttons to select MA SL item Press the ENTER button Use the UP DOWN buttons to select either
25. the fast moving development of LED technology newer products may have better light parameters than previous products 25 ArcPad 48 Integral RGBW 10 Cleaning and maintenance DANGER Disconnect from the mains before starting any cleaning or maintenance work Rinse off loose dirt with low pressure water spray Wash the housing with a soft brush or sponge and a mild non abrasive washing detergent Rinse it There are no serviceable parts inside the device Maintenance and service operations are only to be carried out by a qualified person Should you need any spare parts please use genuine parts 11 Apendix 11 1 ArcPad 48 Integral EPS Besides the ArcPad 48 Integral exists variant with separated LED module and the base which is named the ArcPad 48 integral EPS Its differences compared to the ArcPad Xtreme integral are described below Control ans setting is the same as at the compact version Connection betwen the LED module and the base Chogori OBBMMA SLE001 male Rear view AE Igus CFD9 03 08 Pin Function Wire 1 Red 2 White Pink 3 4 Blue Red 5 6 7 8 Rear view male Chogori female O8BFFA SL8001 Rear view a Igus CFD9 03 08 Function Wire Red e White Pink White Blue Blue Red Blue White Green Brown Greent Yellow Redt Green Rear view OVAMLON A7 If the LED module and the base are installed separately on the metal struct
26. ure LED module and the base are galvanic interconnected the LED modules fall under protection class and must be grounded in accordance with all national and local electrical and construction regulations In case that LED modules and the base are installed separately on the insulant e g wall LED modules and the base are not galvanic interconnected the LED modules fall under protection class 3 and do not need to be grounded 26 ArcPad 48 Integral RGBW Cables e LED module cable Igus CF9 03 08 connector Chogori O8BMMA SL8001 male e Base cable Igus CF9 03 08 connector Chogori O8BFFA SL8001 male NOTE max length betwen the LED module and the control unit 20m Mounting holes bZ IT e STATE mi sp Specifications are subject to change without notice November 5 2013 27