QJ61CL12 CC-Link/LT Master Module User`s Manual (Hardware)
Contents
1. 3 When wiring be careful not to let foreign matter such as wiring chips enter the module inside Remove it if this happens 4 The module has an ingress prevention label on its top to prevent foreign matter such as wire offcuts from entering the module during wiring Do not peel this label during wiring Before starting system operation be sure to peel this label because of heat dissipation 5 Tighten the module fixing screws within the following ranges Tightening torque range Module fixing screw M3 screw 1 0 36 to 0 48N m 1 The module can be easily fixed onto the base unit using the hook at the top of the module However it is recommended to secure the module with the module fixing screw if the module is subject to significant vibration When removing the terminating resistor due to any system modification be sure to power OFF the system Removing Installing the terminating resistor with the power ON may cause malfunctions faulty input output 3 2 Installation environment Refer to the User s Manual of the CPU module in use 3 3 Cables Connectors and Terminating Resistors For inquires about the cables connectors and or terminating resistors refer to the following http www cc link org 4 Name of Parts and Setting QUJ61CL12 Contents Module condition is checked with LED status Description QJ61CL12 po Desorption RUN ON Module operating normally RUN _LRUN OFF Fault in hardware ERR
2. AND GUIDELINES FOR the PRODUCT Prohibited Application Prohibited Applications include but not limited to the use of the PRODUCT in e Nuclear Power Plants and any other power plants operated by Power companies and or any other cases in which the public could be affected if any problem or fault occurs in the PRODUCT e Railway companies or Public service purposes and or any other cases in which establishment of a special quality assurance system is required by the Purchaser or End User e Aircraft or Aerospace Medical applications Train equipment transport equipment such as Elevator and Escalator Incineration and Fuel devices Vehicles Manned transportation Equipment for Recreation and Amusement and Safety devices handling of Nuclear or Hazardous Materials or Chemicals Mining and Drilling and or other applications where there is a significant risk of injury to the public or property Notwithstanding the above restrictions Mitsubishi may in its sole discretion authorize use of the PRODUCT in one or more of the Prohibited Applications provided that the usage of the PRODUCT is limited only for the specific applications agreed to by Mitsubishi and provided further that no special quality assurance or fail safe redundant or other safety features which exceed the general specifications of the PRODUCTs are required For details please contact the Mitsubishi representative in your region ABOUT MANUAL The following manual is also
3. LERR ON Faulty switch setting Blink Switched during operation lt When normal gt ON Data link being executed OFF Data link stopped L RUN lt In test mode gt ON Self loopback test resulted in normal OFF Self loopback test failure 1 LED indicator lt Usually gt ON Faulty data link station or station outside control range detected L ERR Blink Data link failure at all stations lt In test mode gt ON Self loopback test failure OFF Self loopback test resulted in normal ON_ Data being transmitted RD ON Data being received 2 Operation setting Setting I O points occupied transmission rate etc of QU61CL12 Factory switches setting OFF lO points 16 pts 32 pts 48 pts 64 pts 128 pts 256 pts 512 pts 1024 pts 1 0 POINTS y O ZO oO mle ccine 156kbps 625kbps 2 5Mbps __ Setting prohibited OFF ON OFF ON OFF ON ON Point mode 8 point mode 4 point mode 16 point mode Setting prohibited tin OFF ON OFF MODE OFF OFF ON Test mode Lehel stot y w Po gt 4 m B RATE n L S no D E n E 2 D Q O OFF ON LINE Normal operation ON Test mode Self loopback test When the switch is set to this ERR LED will light up 3 CC Link LT interface Connector for CCLink LT communication line connection connector Serial number plate Indicates the serial No of the QJ61CL12 The settings o
4. Pee point mode 8 point mode _ 16 point mode Maximum link points 256 points 512 points 1024 points When the same I O address is used 512 points 1024 points 2048 points Link points per station 16 points When the same I O address is used 8 points 16 points 32 points Number of 128 points 256 points 512 points Control specifications 2 5Mbps 625kbps 156kbps BITR Broadcastpolling Interval Timed Response Communication path T branch type icati eto detach function automatic return function Dedicated flat cable 0 75mm x 4 5 VCTF cable 4 High flexible cable 5 RAS oriented functions Connection cable 1 I O occupied points 2 5VDC internal current consumption Voltage Current consumption Current on startup 0 09kg 1 Performance of the CC Link LT cannot be guaranteed for use of cables other than the dedicated flat cables VCTF cables and high flexible cables 2 Set with the operation setting switch Refer to Chapter 4 3 Supplied through the dedicated power supply or power supply adapter 4 For VCTF cable specifications refer to Table 2 1 5 Use the dedicated flat cables and high flexible cables accredited by the CC Link Partner Association http www cc link org Table 2 1 VCTF cable specifications Extract from JIS C 3306 Conductor Conductor Type No off Nominal Composition Outside insulator Sheath resistance cores cross sectional No of wires wire diameter thickness t
5. required and always forward it to the end user Design Precautions Do not bunch the control wires or communication cables with the main circuit or power wires or install them close to each other They should be installed 100mm 3 9inch or more from each other Not doing so could result in noise that would cause erroneous operation Installation Precautions Use the programmable controller in an environment that meets the general specifications contained in the CPU user s manual to use Using this programmable controller in an environment outside the range of the general specifications could result in electric shock fire erroneous operation and damage to or deterioration of the product While pressing the installation lever located at the bottom of module insert the module fixing tab into the fixing hole in the base unit until it stops Then securely mount the module with the fixing hole as a supporting point Incorrect loading of the module can cause a malfunction failure or drop When using the programmable controller in the environment of much vibration tighten the module with a screw Tighten the screw in the specified torque range Undertightening can cause a drop short circuit or malfunction Overtightening can cause a drop short circuit or malfunction due to damage to the screw or module Completely turn off the externally supplied power used in the system before mounting or removing the module Not doing
6. MITSUBISHI QJ61CL12 CC Link LT Master Module Thank you for purchasing the Mitsubishi general purpose programmable controller MELSEC Q Series Before starting use please read through this manual and the details manual to ensure correct usage User s Manual Hardware QJ61CL12 U HW JE MELSEG Q Mitsubishi Programmable Controller 13JP01 IB NA 0800232 E 1009 MEE 2002 MITSUBISHI ELECTRIC CORPORATION SAFETY PRECAUTIONS Always read these instructions before using this equipment Before using this product please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly These instructions apply only to Mitsubishi equipment Refer to the user s manual of the CPU module to use for a description of the programmable controller system safety instructions In this manual the safety instructions are ranked as A WARNING and A CAUTION Indicates that incorrect handling may cause hazardous N WARNING conditions resulting in death or severe injury Indicates that incorrect handling may cause hazardous A CAUTION conditions resulting in medium or slight personal injury or physical damage Note that the A CAUTION level may lead to a serious consequence according to the circumstances Always follow the instructions of both levels because they are important to personal safety Please save this manual to make it accessible when
7. When disconnecting a communication cable or power cable from the module do not hold and pull the cable portion by hand For the cable with a connector hold the connector connected to the module with a hand and pull it out For the cable connected to a terminal block loosen the screws on the terminal block and disconnect the cable Pulling the cable with it connected to the module may result in malfunctions or damage to the module and or cables CONDITIONS OF USE FOR THE PRODUCT 1 Mitsubishi programmable controller the PRODUCT shall be used in conditions i where any problem fault or failure occurring in the PRODUCT if any shall not lead to any major or serious accident and ii where the backup and fail safe function are systematically or automatically provided outside of the PRODUCT for the case of any problem fault or failure occurring in the PRODUCT 2 The PRODUCT has been designed and manufactured for the purpose of being used in general industries MITSUBISHI SHALL HAVE NO RESPONSIBILITY OR LIABILITY INCLUDING BUT NOT LIMITED TO ANY AND ALL RESPONSIBILITY OR LIABILITY BASED ON CONTRACT WARRANTY TORT PRODUCT LIABILITY FOR ANY INJURY OR DEATH TO PERSONS OR LOSS OR DAMAGE TO PROPERTY CAUSED BY the PRODUCT THAT ARE OPERATED OR USED IN APPLICATION NOT INTENDED OR EXCLUDED BY INSTRUCTIONS PRECAUTIONS OR WARNING CONTAINED IN MITSUBISHI S USER INSTRUCTION AND OR SAFETY MANUALS TECHNICAL BULLETINS
8. ain Mitsubishi Electric Europe B V Spanish Branch Carretera de Rubi 76 80 E 08190 Sant Cugat del Valles Barcelona Spain Tel 34 93 565 3131 Indonesia P T Autoteknindo Sumber Makmur Muara Karang Selatan Block A Utara No 1 Kav No 11 Kawasan Industri Pergudangan Jakarta Utara 14440 P O Box 5045 Jakarta 11050 Indonesia Tel 62 21 6630833 France Mitsubishi Electric Europe B V French Branch India 25 Boulevard des Bouvets F 92741 Nanterre Cedex France TEL 33 1 5568 5568 Messung Systems Pvt Ltd Electronic Sadan NO III Unit No15 M 1 D C Bhosari Pune 411026 India Tel 91 20 2712 3130 South Africa Circuit Breaker Industries Ltd Australia Mitsubishi Electric Australia Pty Ltd Private Bag 2016 ZA 1600 Isando 348 Victoria Road Rydalmere South Africa N S W 2116 Australia Tel 27 11 928 2000 Tel 61 2 9684 7777 MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN NAGOYA WORKS 1 14 YADA MINAMI 5 CHOME HIGASHI KU NAGOYA JAPAN Specifications subject to change without notice
9. f operation setting switches become valid when the module is turned ON from OFF or when the programmable controller CPU is reset When any of settings are changed with the module powered ON ERR LED will blink In this case turn OFF and restart the system 5 External Wiring The connection method of the CC Link LT connection cables is described below 1 The cables can be connected regardless of the order of the station number 2 Be sure to set the QJ61CL12 at the end of the trunk line The terminating resistor close to the QJ61CL12 should be connected within 20cm from the QJ61CL12 3 Connect terminating resistors to the both ends of the trunk line of CC Link LT without fail 4 For required number of the connectors refer to the CC Link LT Master Module User s Manual 6 External Dimensions QJ61CL12 L RUN QU61CL12 LI 91 23 0 91 90 3 54 Unit mm inch Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi machine damage or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties Country Region Sales office Tel Country Region Sales office Tel U S A Mitsubishi Electric Automation Inc Hong Kong Mitsubishi Electric Automation 500 Corporate Woods Pa
10. hickness 20 C area diameter 24V DC power supply Vinyl cabtyre 2 25 1Q 2 2 Network wiring specifications The network wiring specifications of the CC Link LT are given below Transmission rate 2 5Mbps 625kbps 156kbps Distance between stations Nolimited E a Cable length between 2 Length of trunk line 35m 100m 500m terminating resistors Drop line length not included T branch interval No limited Pe Max length of drop line Cable length per branch line Overall length of drop lines Total length of all drop lines T branch p J eae Length of trunk line Drop line not included Master station k gt Interval length of T branch x Remote Remote Remote Remote Terminating Terminating line Power Remote resistor supply station station station station station _ resistor adapter Remote Remote station T station Distance Length of drop line between stations Trunk line Remote Remote Son station Drop line Remote station 3 Mounting and installation 3 1 Precautions for handling The precautions for handling the module are given below 1 The module is mode of resin Do not drop or give it a strong impact 2 Do not remove the PCB printed circuit board from the case Doing so may cause failure
11. related to this product In necessary order it by quoting the details in the table below Related Manual Manual number Model code CC Link LT Master Module User s Manual 1 3JR62 E Conformation to the EMC Directive and Low Voltage Instruction 1 For programmable controller system To configure a system meeting the requirements of the EMC and Low Voltage Directives when incorporating the Mitsubishi programmable controller EMC and Low Voltage Directives compliant into other machinery or equipment refer to Chapter 9 EMC AND LOW VOLTAGE DIRECTIVES of the QCPU User s Manual Hardware Design Maintenance and Inspection The CE mark indicating compliance with the EMC and Low Voltage Directives is printed on the rating plate of the programmable controller 2 For the product For the compliance of this product with the EMC and Low Voltage Directives refer to Chapter 9 EMC AND LOW VOLTAGE DIRECTIVES of the QCPU User s Manual Hardware Design Maintenance and Inspection 1 Overview This manual describes the specifications names of each part and the settings etc for the QJ61CL12 CC Link LT master module hereinafter QJ61CL12 used in combination with the MELSEC Q Series programmable controller CPU 2 Specifications 2 1 Performance specifications The performance specifications of the QJ61CL12 are shown below Refer to the user s manual of the CPU module in use for the general specifications of the QJ61CL12 Specifications
12. rkway Vernon Hong Kong Ltd Hills IL 60061 U S A 10th Floor Manulife Tower 169 Electric Tel 1 847 478 2100 Road North Point Hong Kong Tel 852 2887 8870 Brazil MELCO TEC Rep Com e Assessoria ee Tecnica Ltda China Mitsubishi Electric Automation Rua Correia Dias 184 China Ltd 4 F Zhi Fu Plazz No 80 Xin Chang Road Shanghai 200003 China Tel 86 21 6120 0808 Edificio Paraiso Trade Center 8 andar Paraiso Sao Paulo SP Brazil Tel 55 11 5908 8331 Taiwan Setsuyo Enterprise Co Ltd Germany Mitsubishi Electric Europe B V German 6F No 105 Wu Kung 3rd Rd Wu Ku Branch nai Hei Gothaer Strasse 8 D 40880 Ratingen Saha eerie ai GERMANY Tel 49 2102 486 0 Korea Mitsubishi Electric Automation Korea Co Ltd 1480 6 Gayang dong Gangseo ku U K Mitsubishi Electric Europe B V UK Seoul 157 200 Korea Branch Tel 82 2 3660 9552 Travellers Lane Hatfield Hertfordshire AL10 8XB U K Singapore Mitsubishi Electric Asia Pte Ltd Tel 44 1707 276100 307 Alexandra Road 05 01 02 Mitsubishi Electric Building Singapore 159943 Italy Mitsubishi Electric Europe B V Italian Tel 65 6470 2460 Branch Centro Dir Colleoni Pal Perseo Ingr 2 Thailand Mitsubishi Electric Automation Thailand Via Paracelso 12 I 20041 Agrate Brianza Co Ltd Milano Italy Bang Chan Industrial Estate No 111 Moo 4 Serithai Rd T Kannayao A Kannayao Bangkok 10230 Thailand Tel 66 2 517 1326 Tel 39 039 60531 Sp
13. so could result in damage to the product Do not directly touch the module s conductive parts or electronic components Touching the conductive parts could cause an operation failure or give damage to the module Wiring Precautions N WARNING Shut off the external power supply for the system in all phases before wiring Failure to do so may result in electric shock or damage to the product Be sure there are no foreign substances such as sawdust or wiring debris inside the module Such debris could cause fires damage or erroneous operation The module has an ingress prevention label on its top to prevent foreign matter such as wire offcuts from entering the module during wiring Do not peel this label during wiring Before starting system operation be sure to peel this label because of heat dissipation For the CC Link LT use the cables specified by the CC Link Partner Association The performance of the CC Link LT cannot be assured if any other cables than the specified are used Also observe the network wiring specifications given in Chapter 2 Normal data communication is not guaranteed if the wiring is not conducted according to the specifications Place the communication cables or power cables for the module in a duct or to fasten them with clamps If not the dangling condition shift or inadvertent pulling of the cables may lead to damage to the module or cables or a malfunction due to faulty cable connection