1. Humidifier performance Symbols which appear on the device General Warnings Limited Warranty eec eed Meee TE Introduction The H4i is designed to moisten the air delivered to your airway during Positive Airway Pressure PAP therapy Indications for use The H4i is indicated for humidification of the air delivered from a ResMed compatible CPAP bilevel and non invasive ventilation device The H4i is for use only as recommended by a physician Contraindications The H4i is contraindicated for use with patients whose upper supraglottic airway has been bypassed Please also refer to the relevant system manual for contraindications associated with PAP therapy Components of your H4i Accessories H4i Water Chamber HA Cleanable Water Chamber ResMed Tubing Wrap Air outlet Control dial Indicator light Docking station Water chamber Heater plate Spill guard Latch Setting up your H4i for use Preparation b Remove the connector plug from your flow generator a and attach it to the back of the docking station b Introduction 1 English System setup Align your H4i with your flow generator and push them together until they click into place Connect the power cord to the soc Plug the other end of the power co Place the combined unit on a firm et on the rear of your flow generator rd into the power outlet evel surface near your bed at a
2. example following a stroke Attention should be given to the relative risks and benefits Do not attempt to dismantle the H4i docking station There are no userserviceable parts inside Repairs and internal servicing should only be performed by an authorised service agent If liquids are inadvertently spilled into or on the H4i docking station unplug the PAP device from the power outlet Disconnect the docking station from the PAP device and allow the docking station to drain and dry before using Do not operate the H4i if it is not working properly or if any part of the PAP device or H4i has been dropped or damaged Keep the PAP device power cord away from hot surfaces Do not drop or insert any object into any opening or tubes Donotuse the H4i in the presence of flammable or explosive materials Explosion hazard do not use in the vicinity of flammable anesthetics Follow all precautions when using supplemental oxygen General warnings 11 12 Limited warranty ResMed Ltd hereafter ResMed warrants that your ResMed product shall be free from defects in material and workmanship from the date of purchase for the period specified below Product Warranty period Mask systems including mask frame cushion headgear 90 days and tubing excluding single use devices Accessories excluding single use devices Flextype finger pulse sensors Humidifier water tubs Batteries for use in ResMed
3. how long an implied warranty lasts so the above limitation may not apply to you ResMed shall not be responsible for any incidental or consequential damages claimed to have resulted from the sale installation or use of any ResMed product Some regions or states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from region to region For further information on your warranty rights contact your local ResMed dealer or ResMed office Filling the water chamber Auff llen der Befeuchterkammer Remplissage du r servoir Riempimento della camera dell acqua Llenado de la camara de agua Encher a c mara de gua Vullen van het waterreservoir 248659 1 201207 USER Global leaders in sleep and respiratory medicine www resmed com
4. start warming up the humidifier prior to starting treatment If the humidifier is heating the related symbol is displayed at the top of the LCD screen Note The H4i can only be used when the device is connected to mains power supply CAUTION H4i cannot be used for treatment pressures exceeding 25 cm H30 Starting your treatment 1 3 Turn the humidity control dial to three Ill You can adjust the control dial up or down at any time to find the setting that is most comfortable for you The O setting switches heated humidification off and delivers minimum humidification while a setting of six WII delivers maximum humidification Note The ResMed Tubing Wrap is designed to enhance comfort by maximising heat retention along the air tube Start treatment as described in your device user guide Note The H4i is thermostatically controlled to maintain a constant temperature The indicator light will brighten to indicate when the device is actively heating and dim when it has reached its set temperature Lie down and arrange the tubing so that it moves freely when you turn in your sleep WARNING Do not leave an excessive length of air tubing around the top of your bed It could twist around your head or neck while you are sleeping Stopping your treatment To stop your treatment refer to your device user guide Note In order to assist the heater plate in cooling some flow generators continue to blow air gently for up to an
5. RESMED H4i HEATED HUMIDIFIER User Guide English RESMED H4i HEATED HUMIDIFIER User Guide English Manufacturer ResMed Ltd 1 Elizabeth Macarthur Drive Bella Vista NSW 2153 Australia Distributed by ResMed Corp 9001 Spectrum Center Boulevard San Diego CA 92123 USA EC REP ResMed UK Ltd 96 Milton Park Abingdon Oxfordshire 0X14 4RY UK See www resmed com for other ResMed locations worldwide For patent information see www resmed com ip H4i S8 Stellar and VPAP are trademarks of ResMed Ltd and VPAP is registered in U S Patent and Trademark Office 2012 ResMed Ltd 248659 1 2012 07 Contents IntroduCtON cs 22808 a a RE CARE RE netu 1 Indications for use Contraindications Components of your H4i 1 Setting up your Hdi for use 1 Preparation System setup Filling the water chamber Detaching your H4i Starting and stopping treatment Warming your H4i with the VPAP or S8 Series Warming your H4i with the Stellar 150 Starting your treatment Stopping your treatment Cleaning and maintenance Disassembling the H4i cleanable water chamber Cleaning your H4i Reassembling the H4i cleanable water chamber Reassembling your H4i Servicing Frequently asked questions Troubleshooting Technical specifications
6. fer to your CPAP bilevel or non invasive ventilation device user guide 20 C to 60 C 10 95 non condensing Class II double insulation Type BF Applied Part Please refer to your flow generator user s manual for details Humidifier performance The following settings have been tested at 22 C 40 RH ambient conditions CPAP mask pressure RH output Nominal system output AH BTPS cm H20 Setting 3 Setting 6 Setting 3 Setting 6 4 gt 95 gt 95 16 20 10 gt 85 gt 95 14 18 20 gt 75 gt 85 13 16 AH Absolute Humidity in mg L t BTPS Body Temperature Pressure Saturated Note The manufacturer reserves the right to change these specifications without notice 10 Symbols which appear on the device A Caution Read instructions before use European Authorised English Representative Type BF Applied Part 22 Hot surface Class Il equipment X Do not touch 46 Humidifier control Y LA MAX Maximum water level mal Manufacturer Environmental information EH WEEE 2002 96 EC is a European Directive that requires the proper disposal of electrical and electronic equipment This device should be disposed of separately not as unsorted municipal waste To dispose of your device you should use appropriate collection reuse and recycling systems available in your region The use of these collection reuse and recycling Systems is designed to reduce pressure on natural resources and pre
7. horised ResMed Service Centre five years from the date of manufacture Prior to this the device is intended to provide safe and reliable operation provided that it is operated and maintained in accordance with the instructions provided by ResMed Warranty details are provided with the device at the time of original supply As with all electrical devices if any irregularity becomes apparent you should exercise caution and have the device inspected by an authorised ResMed Service Centre Frequently asked questions Question Answer Why is there Excessive condensation in your mask or air tubing may occur when the room condensation in temperature is low To prevent condensation turn the control dial down to a my mask and or lower setting You may need to adjust your humidity setting from season to air tubing season The use of a ResMed Tubing Wrap can help reduce the effects of condensation Do have to use Using distilled water will maximise the life of the water chamber and reduce distilled water mineral deposits in the water chamber What if still If you have symptoms of dryness then your humidity setting may be set too have symptoms low to be effective Turn the humidity control dial up of dryness If you are still experiencing symptoms of dryness you may be breathing through your mouth Mouth breathing or mouth leaks cause drying and irritation of the upper airway If this is a problem a full face mask or chin strap
8. hour after treatment has stopped However you can unplug the device from the power outlet at any time and allow the heater plate to cool without airflow Cleaning and maintenance You should regularly carry out cleaning and maintenance of the water chamber cover and cover seal as described in this section WARNING Beware of electrocution Do not immerse your flow generator docking station or power cord in water Always unplug the device before cleaning and be sure that it is dry before plugging it back in Take care when handling your Hdi The water and the water chamber base may both be hot Allow 10 minutes for the heater plate and any excess water to cool Disassembling the H4i cleanable water chamber Remove the spill guard by pushing up from inside the air inlet and pulling it away from the water chamber Discard any excess water from the water chamber Turn the water chamber upside down Using the side tabs disengage the latch by pushing the latch up and away Remove the tub plate Remove the tub plate seal Note Only the H4i Cleanable Water Chamber can be disassembled reassembled Cleaning and maintenance 5 English Cleaning your H4i Water chamber N A Ww Daily Wash the water chamber spill guard tub plate and tub plate seal in warm water using a mild detergent Use the yellow cleaning plug to assist in the cleaning process see steps 1 to 4 Rinse thoroughly in clean water and allow
9. internal and external battery 6 months systems Clip type finger pulse sensors 1 year CPAP and bilevel device data modules Oximeters and CPAP and bilevel device oximeter adapters e Humidifiers and humidifier cleanable water tubs Titration control devices CPAP bilevel and ventilation devices including external 2 years power supply units Battery accessories Portable diagnostic screening devices This warranty is only available to the initial consumer It is not transferable If the product fails under conditions of normal use ResMed will repair or replace at its option the defective product or any of its components This limited warranty does not cover a any damage caused as a result of improper use abuse modification or alteration of the product b repairs carried out by any service organization that has not been expressly authorized by ResMed to perform such repairs c any damage or contamination due to cigarette pipe cigar or other smoke and d any damage caused by water being spilled on or into an electronic device Warranty is void on product sold or resold outside the region of original purchase Warranty claims on defective product must be made by the initial consumer at the point of purchase This warranty replaces all other expressed or implied warranties including any implied warranty of merchantability or fitness for a particular purpose Some regions or states do not allow limitations on
10. level lower than your sleeping position Ensure the surface is not sensitive to heat and or moisture or use a protective mat Connect one end of the air tubing f irmly onto the air outlet Connect the assembled mask system to the free end of air tubing WARNING Make sure your flow generato connecting the H4i r is switched off at the power outlet before The Hdi docking station should only be connected or disconnected when the water chamber is empty Water must be prevented from entering your flow generator Do not transport the flow generator with the H4i attached The H4iis contraindicated for invasive use An external humidifier approved for invasive use is recommended according to EN ISO 8185 Filling the water chamber Open the cover Remove the water chamber Fill with fresh clean water up to or below the maximum water level mark Note The water chamber must be removed from the H4i before it is filled or water may enter the flow generator The spill guard must also be in place Return the water chamber to the docking station Note Ensure that no water is collected between the heater plate and the water chamber Close the cover ensuring that it clicks into place CAUTION Do not overfill the water chamber as water may enter the flow generator and air tubing Do not use any additives eg scented oils and perfumes They may reduce the humidification output of the H4i and or cause dete
11. may help Consult your clinician or equipment supplier for details Troubleshooting If there is a problem try the following suggestions If the problem cannot be solved contact your equipment supplier or ResMed Do not open the unit WARNING Problem Possible cause Device not working no display on LCD screen and or indicator light not lighting up Power cord is not plugged in properly Faulty power outlet Flow generator and docking station not connected correctly English Service and repair should only be performed by an authorised service agent Solution Check that the power cord is plugged firmly into the power outlet and the switch if available is on at the outlet Try another power outlet Check that the docking station is securely attached to the flow generator Indicator light is permanently dull and or air does not feel warm H4i reflector is dirty Clean the reflector with a damp cloth Leaking water chamber The water chamber may be damaged or cracked The tub plate is not attached Water Chamber correctly not applicable to the H4i Contact your supplier for a replacement Make sure the tub plate is fitted correctly No low air flow The air tubing is not connected properly or punctured correctly The cover seal is not fitted correctly The air tubing is blocked pinched The flow generator is not working The cover is not latched correc
12. rioration of the water chamber materials Detaching your H4i Unplug the power cord from the power outlet WARNING Take care when handling your H4i The water and the water chamber base may both be hot Allow 10 minutes for the heater plate and any excess water to cool Remove the water chamber from the docking station Press the large silver button located midway underneath the docking station Setting up your H4i for use 3 English 4 Pull the H4i and flow generator apart Note Re attach the connector plug firmly to your flow generator Starting and stopping treatment Warming your H4i with the VPAP or S8 Series 1 2 3 The Warm Up feature not available on all ResMed PAP devices is used to pre heat the water before starting treatment Skip this step if you want to start immediately To start the Warm Up feature Select warmup by pressing on the control panel The WARMING screen will appear to indicate that the Warm Up feature is activated While your H4i is in Warm Up mode you can Start treatment at any time by pressing Access the menus by pressing Stop the Warm Up feature at any time by pressing This may not apply on all devices The Warm Up feature will automatically turn off after 30 minutes if treatment has not started Warming your H4i with the Stellar 150 Your H4i will be automatically detected when the Stellar 150 is turned on The treatment screen will give you the option to
13. th CAUTION Do not use any of the following to clean any part of the H4i as these solutions may cause damage and reduce the life of the product bleach chlorine alcohol or ammonia based solutions moisturising antibacterial or glycerine based soaps water softening and unapproved descaling agents Heater plate Do not allow water to collect on the heater plate Wipe it with a clean cloth if necessary Reassembling the H4i cleanable water chamber 1 Refit the tub plate seal into its groove on the cleanable water chamber 2 Reinsert the tub plate by slotting its feet into the catches 3 Reassemble the catch by lifting up and over the water chamber and then pushing down to lock into place Note Only the H4i Cleanable Water Chamber can be disassembled reassembled Cleaning and maintenance 7 English 4 Reinsert the spill guard into the water chamber recess and push down to fit firmly into place Reassembling your H4i Reassemble the parts when they are clean and dry 1 Align the cover seal to the guides on the cover and press along the edges to ensure it is fitted properly 2 Put one cover arm into its pivot point on the docking station and gently flex the other arm into its corresponding point The cover should be able to open and close freely while securely attached to the docking station 3 Replace the water chamber in the humidifier docking station Servicing The H4i should be inspected by an aut
14. them to dry away from direct sunlight Weekly The disassembled cleanable water chamber spill guard tub plate and tub plate seal may be washed in a dishwasher on the delicate or glassware cycle top shelf only Note Not applicable to the H4i Water Chamber Inspect the water chamber for wear and deterioration Replace the water chamber if any component has cracked become cloudy or pitted Replace immediately if there is any leaking from the water chamber White powder or deposits in the water chamber can be cleaned using a solution of one part vinegar to 10 parts water as follows Fill the cleaning plug to the rim with vinegar and pour into empty water chamber Add clean water to the water chamber until the solution reaches the maximum water level mark Let the solution soak for 10 minutes Discard the solution and rinse the water chamber with clean water Cover and cover seal 1 Remove the cover by gently flexing one cover arm away and up from the docking station until the cover detaches completely 2 Peelthe cover seal away from the cover S Inspect the cover and cover seal weekly for wear and deterioration Replace any damaged parts When required wash the cover and cover seal in warm water using a mild detergent Rinse them thoroughly with clean water and allow it to dry away from direct sunlight Docking station Periodically wipe the outside of the docking station including the connector seal with a damp clo
15. tly Connect the air tubing as described in Setting up your H4i for use on page 1 Unblock or free the air tubing Check the air tubing for punctures See the Troubleshooting section in the low generator manual ake sure the cover is latched onto the docking station correctly ake sure the cover seal is facing the right way up and fitted securely Water splashing on your face Condensation is forming in the air tube and mask The water chamber is overfilled Empty some water from the water chamber Turn the control dial down Use the ResMed Tubing Wrap Troubleshooting 9 Technical specifications Maximum heater plate temperature Temperature cut out Maximum gas temperature Dimensions H x W x D Weight Water capacity Power supply Docking station Water chamber Operating temperature Operating humidity Operating altitude Storage and transport temperature Storage and transport humidity IEC 60601 1 classification Electromagnetic compatibility 41 C Docking station and water chamber 130 mm x 170 mm x 212 mm Docking station and unfilled water chamber 786 g To maximum fill line 390 mL 100 240V 50 60Hz 0 7 1 6A 110V 400Hz 0 8A Instantaneous power consumption lt 400W Average power lt 115W Flame retardant engineering thermoplastic plated cast aluminium Injection molded plastic stainless steel and silicon seal 5 C to 35 C 10 95 non condensing Please re
16. vent hazardous substances from damaging the environment If you need information on these disposal systems please contact your local waste administration The crossed bin symbol invites you to use these disposal systems If you require information on collection and disposal of your ResMed device please contact your ResMed office local distributor or go to www resmed com environment General warnings A warning alerts you to possible injury Specific warnings and cautions appear next to the relevant instructions in the manual Use the H4i only for its intended use as described in this manual Make sure that the water chamber is empty before transporting the H4i The H4i is designed only for use with specific ResMed PAP devices Do not use the H4i with any other PAP device The H4i should only be used with delivery tubes or accessories recommended by ResMed Connection of other delivery tubes or accessories could result in injury or damage to the device The H4i including the associated tubing is for single patient use and must not be re used on another person This is to avoid the risk of cross infection There exists the possibility that if the device is placed above the level of the patient and is tipped over or if the tubing is filled with condensate the mask might fill with heated water The H4i should therefore be used with caution in patients who are unable to guard their airways or are unable to pull the mask off for