Home
Amhaze™ Studio User Manual Rev. 1
Contents
1. 1 700 cfm Max External Temperature 104 F 40 C I O Connectors 3 and 5 pin XLR Product Name Amhaze Studio 120 V Amhaze Studio 230 V Range 120 VAC 60 Hz or 230 VAC 50 Hz 120 V 60 Hz 700 W 6 2A 7 AL U S Canada Neutrik amp powerCON A Edison U S Tank Capacity 0 85 gal 3 2 Cooling System Fan Assisted Convection Connector Type Sockets Item Code 05070936 05070937 Voltage Selection Fixed 230 V 50 Hz 250 W 5A 7 AL Worldwide Neutrik amp powerCONG A Local plug Fluid Consumption 18 ml min Channel Range 2 UPC Number 81462212841 81462212858 RoHS A Technical Specifications HAVI PROFESSIONAL Returns You must send the product prepaid in the original box and with the original packing and CONTACT Us accessories Chauvet will not issue call tags Call Chauvet and request a Return Merchandise Authorization RMA number before shipping the product Be prepared to provide the model number serial number and a brief description of the cause s for the return Clearly label the package with an RMA number Chauvet will refuse any product returned without an RMA number DO NOT write the RMA number directly on the box Instead write it on a properly affixed label Once you have received the RMA number include the following information on a piece of paper inside the box Your name Your address Your phone number
2. The RMA number A brief description of the problem s Be sure to pack the product properly Any shipping damage resulting from inadequate packaging will be the customers responsibility FedEx packing or double boxing is recommended d Chauvet reserves the right to use its own discretion to repair or replace returned product s WORLD HEADQUARTERS Chauvet General Information Technical Support Address 5200 NW 108th Avenue Voice 954 577 4455 Press 4 Sunrise FL 33351 Fax 954 756 8015 Voice 954 577 4455 Email tech chauvetlighting com Fax 954 929 5560 Toll free 800 762 1084 World Wide Web www chauvetlighting com UNITED KINGDOM AND IRELAND Chauvet Europe Ltd General Information Technical Support Address Unit 1C Email uktech chauvetlighting com Brookhill Road Industrial Estate Pinxton Nottingham UK World Wide Web www chauvetlighting co uk NG16 6NT Voice 444 0 1773 511115 Fax 44 01773 511110 MEXICO Chauvet Mexico General Information Technical Support Address Av Santa Ana 30 Email servicio chauvet com mx Parque Industrial Lerma Lerma Mexico C P 52000 World Wide Web www chauvet com mx Voice 452 728 285 5000 Outside the U S United Kingdom Ireland or Mexico contact the dealer of record Follow their instructions to request support or to return a product Visit our website for contact details
3. EE 2 ES A ee 2 MOUNTING ANG RIGGING aid 2 A e e etre ent nes eee ER 2 Opera EE 2 2 Ta sels Y Ta PR MEE EE TETTE EDT 3 Re de ON EE A 3 grub eE 3 VS RIS A a E e 4 Riant 5 3 SE HE 6 BO eUT Ucet qui c MU e I IM MM UM er Mu 6 PGP MOG RN EMO NR MNT G e 6 SRISTI e Tn IRE E omm 6 Rik MEI soe Ir 6 DMX Fersonaltie it lt UT Tre 6 MOUNINO Merc A 7 HEET 7 mio Re ETE EE T O PEERS 7 POCOO MN NE ONO POPE REO A A EEPRCERE 7 Amhaze Studio User Manual Rev 1 S Table of Contents CHAUVET A e MM 8 Solis A 8 ENEE eebe 8 A gis ots a Keener rena i a a i heer rn s a 8 Sege Tais or eee RENT TEE oT EP E 8 BND AdAS putemus M LE M t 8 mint 1010 ARA PIU Tn PM S 8 Haze el dun a T H A el 8 PONS OLIN A ee t io ti t 9 DMX Valles a Bt Presa T TET 9 D technical IN O MAalON areas ceca rec osteo NA 10 a GE En Let 10 Se LEE 10 6 LTO UE etonne Te Si iii ki ees 11 EID a H EIS 12 Contact IT ota a oN Ae Oe SE ES A M M aM uM MM T EE End 12 Amhaze Studio User Manual Rev 1 WI Before You Begin 1 BEFORE YOU BEGIN What Is Amhaze Studio Included Neutrik amp powerCON power cord Warranty Card Quick Reference Guide Claims Carefully unpack the product immediately and check the box to make sure all the parts
4. Studio uses up to 2 DMX channels in its DMX mode which defines the highest configurable address to 511 If unfamiliar with DMX download the DMX Primer from www chauvetprofessional com To select the starting address do the following 1 2 Go to the d main level Select a DMX Value 001 512 Fan Control This setting adjusts the fan speed 1 2 Go to the F main level Select 000 005 Haze Volume This setting adjusts the haze volume 1 2 Go to the h main level Select 000 005 Amhaze Studio User Manual Rev 1 LARUN NAL O pera tion Menu Map Main Level Programming Levels Description d 001 512 Selects the DMX starting address F 000 005 Fan speed control h Haze volume control DMX Values 2Ch Channel Function Value Percent Setting 000 005 No function Sas ide 006 255 Fan speed slow to fast 000 005 No function 2 Haze Volume 006 255 Haze volume 1 100 Amhaze Studio User Manual Rev 1 9 v CHAUVET Technical Information 5 TECHNICAL INFORMATION i Do not allow the haze machine to become clogged After every 40 hours of continuous Hazer Maintenance operation use CHAUVET Fog Cleaner Quart FCQ through the system to prevent the accumulation of particulate matter in the heating element The recommended cleaning procedure is as follows 1 Unplug the product from power Empty all haze fluid from the machine Add cleaning solution to the tank Connect the product to p
5. Use on Dimmer Glance outdoor Use X X Fixed Voltage 120 V or 230 V Master Slave X p p X DMX D User Serviceable Amhaze Studio User Manual Rev 1 Safety Notes A D Personal Safety Mounting And Rigging Power And Wiring Operation Read all the following Safety Notes before working with this product These notes include important information about the installation usage and maintenance of this product This product contains no user serviceable parts Any reference to servicing in this User Manual will only apply to properly trained Chauvet certified technicians Do not open the housing or attempt any repairs All applicable local codes and regulations apply to proper installation of this product Depending on the amount of haze generated all haze machines may set off smoke detectors Drain the tank before transporting the product Always disconnect this product from its power source before servicing The product s nozzle is very hot during operation and it remains hot for a long time after operation has stopped Always connect this product to a grounded circuit to avoid the risk of electrocution Do not drink or become in contact with the haze fluid If you do call your local emergency service 911 in the US for help Do not use for space heating purposes Do not touch this product s housing during operation because it may be very hot The product is not intended for permanent installation This pr
6. are in the package and are in good condition If the box or the contents the product and included accessories appear damaged from shipping or show signs of mishandling notify the carrier immediately not Chauvet Failure to report damage to the carrier immediately may invalidate your claim In addition keep the box and contents for inspection For other issues such as missing components or parts damage not related to shipping or concealed damage file a claim with Chauvet within 7 days of delivery Manual Convention Meaning Conventions 1 512 A range of values in the text 50 60 A set of mutually exclusive values in the text SET A button on the product s control panel Settings A product function or a menu option MENU gt Settings A sequence of menu options 1 10 A range of menu values from which to choose in a menu Yes No A set of two mutually exclusive menu options in a menu ON A unique value to be entered or selected in a menu Symbols Symbols Meaning Critical installation configuration or operation information Failure to comply with this information may cause the product not to work damage third party equipment or cause harm to the operator i Important installation or configuration information Failure to comply with this information may keep the product from working Useful information 3 The term DMX used throughout this manual refers to the USITT DMX512 A digital data transmission protocol Product At A
7. ation may affect the product If hanging this product make sure that the mounting location can support the product s weight See the Technical Specifications for the weight bearing requirements of this product When hanging this product always secure to a fastening device using a safety cable For our CHAUVET Professional line of safety cables go to http trusst com products Procedure The Amhaze Studio has a threaded mounting hole size M12 at the top of the hazer This mounting hole is appropriate for use with a mounting clamp You must supply your own mounting clamps so be sure the clamp is capable of supporting the weight of this product For our CHAUVET Professional line of mounting clamps go to http trusst com products Safety Cable M12 Mounting Rini Mounting Diagram Floor Mounting Overhead Mounting Amhaze Studio User Manual Rev 1 7 Operation HAVI PROFESSIONAL 4 OPERATION Control Panel Description Button Function lt MENU gt Exits chooses from the current menu or function lt UP gt Navigates upward through the menu list or increases the numeric value when in a function lt DOWN gt Navigates downward through the menu list or decreases the numeric value when in a function Control vou can set the Amhaze Studio starting address in the 001 512 DMX range This enables Options control of up to 256 products in the 2 channel personality Programming Refer to the Menu Map to understa
8. exits the nozzle at a very high temperature Keep a minimum distance of 6 5 ft 2 m from the nozzle to the nearest object The product s nozzle is very hot during operation and it remains hot for a long time after operation has stopped The maximum ambient temperature is 104 F 40 C Do not operate this product at a higher temperature In the event of a serious operating problem stop using this product immediately Do not add perfume alcohol gasoline or any other flammables to the haze fluid Use only CHAUVETO water based Premium Haze Fluid PHF and High Performance Haze Fluid HFG In the unlikely event that your Chauvet product may require service contact Chauvet Technical Support Amhaze Studio User Manual Rev 1 2 INTRODUCTION Description The Amhaze Studio is a professional water based haze machine Adjustable via DMX or the LCD screen you can achieve continuous variable haze output and blower speed The hazer is tour ready with a rugged flight case and an M12 threaded rigging insert It can work with a variety of different water based haze fluid types for added versatility Chauvet recommends Premium Haze Fluid PHF and High Performance Haze Fluid HFG available from Chauvet Features Water based haze machine Operating modes 2 channel fan speed and haze output volume Quiet operation for use in theatres and TV studios Variable output of haze for better atmospheric maintenance Large 3 2 fluid capacity and rapid 4
9. in DMX data connection for the 2 channel DMX personality Refer to the Introduction chapter for a brief description of each DMX personality Refer to the Operation chapter to learn how to configure the Amhaze Studio to work in these personalities The DMX Values section provides you with detailed information regarding the DMX personalities If you are not familiar with or need more information about DMX standards Master Slave connectivity or the DMX cables needed to link this product to a DMX controller download the DMX Primer from the Chauvet website http www chauvetlighting com download Amhaze Studio User Manual Rev 1 y UY la Setup Mounting Before mounting this product read and follow the Safetv Notes For our CHAUVETO Professional line of mounting clamps go to http trusst com products Orientation Always mount this product in a safe position and make sure there is adequate room for ventilation configuration and maintenance Rigging Chauvet recommends using the following general guidelines when mounting this product When selecting an installation location consider easy access to this product for operation programming adjustments and routine maintenance The product is not intended for permanent installation Make sure to mount this product away from any flammable material as indicated in the Safety Notes Never mount in places where rain high humidity extreme temperature changes or restricted ventil
10. iprofessional com Always connect this product to a protected circuit with an appropriate electrical ground to avoid the risk of electrocution or fire Never connect this product to a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel serves only as a 0 to 100 switch The Amhaze Studio comes with a power input cord terminated with a Neutrik powerCON A connector on one end and an Edison plug on the other end U S market If the power input cord that came with your product has no plug or if you need to change the Edison plug use the table below to wire the new plug Connection Wire U S Wire Europe Screw Color AC Live Yellow or Brass AC Neutral Sive AC Ground Green Yellow Green Yellow Green 1 Disconnect this product from the power outlet 2 Using a Phillips head screwdriver unscrew the fuse holder cap from the housing 3 Remove the blown fuse and replace with another fuse of the same type and rating F 7 AL 250 V 4 Screw the fuse holder cap back in place and reconnect power Make sure to disconnect the product s power cord before replacing a blown fuse Always replace the blown fuse with another of the same type and rating You can link the Amhaze Studio to a DMX controller using a 3 or 5 pin DMX connection If using other DMX compatible products with the Amhaze Studio you can control each individually with a single DMX controller The Amhaze Studio uses a 3 or 5 p
11. mhaze Studio User Manual Edition Notes Edition Notes Trademarks Copyright Notice Manual Use Document Printing Intended Audience Disclaimer Document Revision Tf PROFESSIONAL The Amhaze Studio User Manual Rev 1 covers the description safety precautions installation programming operation and maintenance of the Amhaze Studio Chauvet released this edition of the Amhaze Studio User Manual in February 2015 CHAUVETO is a registered trademark of CHAUVET amp Sons Inc d b a CHAUVET or Chauvet The CHAUVETO logo in its entirety including the CHAUVET name and the dotted triangle and all other trademarks in this manual pertaining to services products or marketing statements example Its Green Thinking are owned or licensed by Chauvet Any other product names logos brands company names and other trademarks featured or referred to within this document are the property of their respective trademark holders Chauvet owns the content of this User Manual in its entirety including but not limited to pictures logos trademarks and resources Copyright 2015 Chauvet All rights reserved Electronically published by Chauvet in the United States of America Chauvet authorizes its customers to download and print this manual for professional information purposes only Chauvet expressly prohibits the usage copy storage distribution modification or printing of this manual or its content for a
12. minute heat time Ready lights signals the user when heating is complete Digital display for DMX addressing and stand alone functions Flight case integrated into design Amhaze Studio User Manual Rev 1 3 db Introduction vie TEI Overview DMX Out Control Panel Fluid Tank DMX In Fuse Knozzle Power In va a e EI Fluid Hose M12 Threaded Mounting Hole Top View AS Amhaze Studio User Manual Rev 1 Introduction A A A H 8 70in 9 53in 10 24 in 10 78 in Se 221 mm 242 mm 260 mm 274 mm 15 82 in 402 mm 4 13 31in 338 mm Amhaze Studio User Manual Rev 1 Y Y Y 17 75 in lt 451 mm gt 17 05 in lt 433 mm 15 83 in 402 mm 12 13 in 308 mm Setup 3 SETUP AC Power A D AC Plug Fuse Replacement A DMX Linking DMX Personalities HAVI PROFESSIONAL The Amhaze Studio has a fixed power supply that works with an input voltage of either 120 VAC 60 Hz or 230 VAC 50 Hz depending on the specific model To determine the power requirements for each Amhaze II refer to the label affixed to the product You can also refer to the Technical Specifications chart in this manual The listed current rating indicates the maximum current draw during normal operation For more information you may download Sizing Circuit Breakers from the CHAUVET website www chauve
13. nd the menu options The menu map shows the main level and a variable number of programming levels for each option Preparing for To 1 Operation gt Oo E OM To go to the desired main level press MENU repeatedly until the option shows on the display This will take you to the first programming level for that option To select an option or value within the current programming level press UP or lt DOWN gt until the option shows on the display Press MENU repeatedly to exit to the previous main level prepare the Amhaze Studio for operation perform the following steps Open the flight case Withdraw the fluid tank from its compartment and remove its cap Verify that the two plastic hoses attached to the cap are in place and in good condition Pour CHAUVET PHF or HFG haze fluid into the tank and replace the cap Put the tank back into its compartment in the hazer Make sure the plastic hose entering the hazer from the fluid tank cap is not bent or kinked Connect the hazer to power After approx 4 minutes the machine is ready to output haze The Amhaze Studio does not have an On Off switch As soon as you connect the Amhaze Studio to power it will start operating DMX Address When selecting a starting DMX address always consider the number of DMX channels the DMX mode uses If you choose a starting address that is too high you could restrict the access to some of the product s channels The Amhaze
14. ny other purpose without written consent from Chauvet For better results print this document in color on letter size paper 8 5 x 11 in double sided If using A4 paper 210 x 297 mm configure your printer to scale the content accordingly Any person in charge of installing operating and or maintaining this product should completely read through the guide that shipped with the product as well as this manual before installing operating or maintaining this product Chauvet believes that the information contained in this manual is accurate in all respects However Chauvet assumes no responsibility for any errors or omissions in this document Chauvet reserves the right to revise and make changes to the content of this document without obligation that Chauvet notify any person or company of such revision or changes This does not in any way constitute a commitment by Chauvet to make such changes Chauvet may issue a revision of this manual or a new edition to incorporate such changes The Amhaze Studio User Manual Rev 1 is the first edition of this manual www chauvetprofessional com for the latest version Author D Couppe Go to Editor A Leon Date 2 10 15 Date 2 10 15 Amhaze Studio User Manual Rev 1 Table of Contents UN Berore ou DOI w G G C 1 Whal E ee EE 1 IE HE rm 1 Mandal cie Te BRETT EON emm 1 Sn A PE 1 PTOGUGEALA al LING e ie e ra O 1 DIOL ING
15. oduct is for indoor use only To prevent risk of fire or shock do not expose this product to rain or moisture IP20 CAUTION When transferring product from extreme temperature environments e g cold truck to warm humid ballroom condensation may form on the internal electronics of the product To avoid causing a failure allow product to fully acclimate to the surrounding environment before connecting it to power Mount this product in a location with adequate ventilation at least 20 in 50 cm from adjacent surfaces Make sure there are no flammable materials close to this product while it is operating When hanging this product always secure to a fastening device using a safety cable Always make sure you are connecting this product to the proper voltage in accordance with the specifications in this manual or on the product s specification label To eliminate unnecessary wear and improve its lifespan during periods of non use completely disconnect the product from power via breaker or by unplugging it Never connect this product to a dimmer pack or rheostat Never disconnect this product by pulling or tugging on the power cable Do not operate this product if you see damage to the housing fluid tank or cables Have the damaged parts replaced by an authorized technician at once Be sure that no ventilation slots on the product s housing are blocked Never carry the product from the power cord or any moving part Always use the handles The haze
16. ower and allow it to warm up Run the unit in a well ventilated area until the tank is empty Refill with haze fluid to continue using the hazer Run the machine briefly to clear any cleaning solution from the pump and heater D FCQ Fog Cleaner Quart was specifically developed by CHAUVETO to clean your DN PWN Amhaze Studio Make sure you use FCQ regularly to increase the life of your hazer AN Do not spin the fans using compressed air because you could damage the hazer Storage Before storing the hazer run FCQ through the system as described in the cleaning procedure above however only follow steps 1 through 5 Do not refill the tank with hazer fluid if storing the hazer Cleaning the system prior to storage will help prevent any particles from condensing inside the pump or heater while not in use Test run your Amhaze Studio on a monthly basis to achieve the best performance AO Amhaze Studio User Manual Rev 1 Technical Specifications 6 TECHNICAL SPECIFICATIONS Dimensions and Weight Power Operation Capacity Consumption Misc Thermal DMX Ordering Length 17 75 in 451 mm Width 15 82 in 402 mm Height 10 78 in 274 mm Weight 34 4 lb 15 7 kg Note Dimensions in inches rounded to the nearest decimal digit Power Supply Type Model specific Parameter Consumption Operating current Fuse Power Power input connector Power cord plug Heat up Time 4 min Output