1. General laboratory use 1 3 The M150 Features Professional high quality UV meter Ultraviolet irradiation measurement of UV UV detector spectrum from 290 390 nm anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412 e Measurement range 3999 uW cm and 39 99 W cm Zero button Microprocessor circuit provides high reliability and durability Separate UV LIGHT probe allows user to measure the UV light at an optimum position Easy read read large LCD Overload display OL Power off Manual on off by push button or auto shut off after 15 minutes 2 Safety Summary A Adhere to the following conditions for safe and effective usage of this meter This is a precision device During use or storage do not go beyond its specifications to prevent any possible damage or danger Do not operate the meter in an environment filled with combustible gas liquids dust or fibers n order to avoid reading incorrect data please replace the battery immediately when the symbol E appears on the LCD Do not store this device in direct sunlight or where it is hot and or damp anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412 Remember to turn OFF the power after use For long storage remove the battery to prevent the battery from leaking to cause damage to the parts inside Operat
2. ANAHEIM SCIENTIFIC User Manual Model M150 Mini UV AB Meter Table of Contents 1 INTRODUCTION cccssscseseseseessseseeeesesensseeseeeeeseeeeeesaseneaeenesenenseees 3 1 1 M150 Applications 1 2 Laboratory Applications 1 3 The M150 Features m SAFETY SUMMARY eese enenetntntnnnntn tn tn ener tntn tne nnn 4 COMPLIANCE STATEMENTS eere 5 PRODUCT CONTENTS AND INSPECTION DEVICE DESCRIPTION a RON 5 1 5 2 6 DEVICE OPERATION 6 1 6 2 6 3 6 4 6 5 Data Hold Button 5 5 0 ttr ient tilii eie teres 9 6 6 Battery Replacement sssssssssseeeeeeneene 10 7 TECHNICAL SPECIFICATIONS 8 SERVICE REPAIRS CALIBRATION 9 LIMITED TWO YEAR WARRANTY eerte 14 anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412 1 Introduction Thank you for purchasing a M150 UV AB Meter from Anaheim Scientific The M150 provides professional high quality UV readings from a small compact meter Durable reliable and easy to use use the M150 for 1 14 M150 Applications Monitoring blue light radiation hazards in welding UV sterilization Graphic arts Photochemical matching Photo resist exposure Curing of inks adhesives and coatings 1 2 Laboratory Applications Weathering degradation studies UV sterilization Virology Microbial genetics DNA research Biologic hoods
3. elegth of 365 nm Display 3 digits LCD with max reading 4000 Units uW cm and mW cm Sampling About 3 seconds Rate Power 2 AAA batteries Supply Battery life 50 hours during consecutive use Dimensions 133 x 48 x 27 mm H x W x D Weight 90g Warranty Limited two year warranty anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412 12 8 Service Repairs Calibration The following are instructions regarding policies for servicing repairing or calibrating Anaheim Scientific products Turnaround time is usually less than ten 10 working days unless expedited service is requested and pre arranged Send an email to service anaheimscientific com requesting an RMA number specifying your request for either service repair and or calibration with your product s model number Once you receive a reply from service anaheimscientific com you will be asked to ship prepaid to the address below Package the unit carefully using filler or bubble wrap and if possible ship in the original box Ship each unit separately Anaheim Scientific is not responsible for any shipping damage that may occur Include a packing list with each unit shipped stating what type of service is required and include the return shipping information name address and telephone number e If the unit is in warranty please provide the following proof of pu
4. ing Environment This instrument has been designed for usage within an environment of Pollution Degree 2 Clean the device with a dry soft cloth Wet cloths liquid and water are prohibited Operating Environment 5 C 40 C 8096 RH lt 2km altitude Storage Environment 10 to 60 C 7096 RH 3 Compliance Statements Caution This symbol indicates that the equipment and its accessories are subject to special collection and disposal procedures This meter is EMC compliant and has undergone tests according to EN61326 1997 A1 1998 A2 2001 anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412 4 Product Contents and Inspection This unit is tested prior to shipment It is therefore ready for immediate use upon receipt An initial physical inspection should be made to ensure that no damage has been sustained during shipment Inspect the packing box on receipt for any external damage If any external damage is evident remove the instrument and visually inspect its case and parts for any damage If damage to the instrument is evident a description of the damage should be noted on the carrier s receipt and signed by the driver or carrier agent Save all shipping packaging for inspection Forward a report of any damage to the agent through which the unit is procured Retain the original packing in case subsequent repackaging for return is requ
5. ired Use of the original packing is essential After the mechanical inspection verify the contents of the shipment The items included in this package are M150 Meter User Manual Carrying Case 2xAAA Batteries anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412 5 Device Description 5 4 LCD Display e o Main display 6 o ZEROES Value hold ZERO display Low power indicator uW cm unit display mW cm unit display Decimal point display BEE eme mom e Dig eG cx 5 2 Control Buttons 1 Power switch button pop ET HoLD 2 Backlight button 3 Hold lock button l 4 Zero button 5 Unit button anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412 6 Device Operation 6 1 Power Button Pressthe oF button to turn ON the power The display comes alive Press the Jg button once again to turn OFF the power and put the device into sleep mode The display changes from light to dark 6 2 Zero Button Press the B button for the zero adjustment if any digits are appearing when the sensor is covered f performing the zero adjustment after powering on several digits may not disappear In this case perform the zero adjustment again 6 3 Backlight Display Press EJ key to turn backlight on Press the B butt
6. on again to power off e Backlight light turns off automatically after 30 seconds anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412 6 4 Unit Button Press the oF button to turn ON the power and put the device to operating mode The screen displays 0000 uW cm Press the B button to switch from 0000uW cm to 00 00mW cm To select a different unit just press this button once again 6 5 Data Hold Button Press the F button to go into hold mode and HOLD appears on the screen to allow you to read the data Press this button once again to deactivate it anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412 10 6 6 Battery Replacement If the symbol Es appears on the LCD please replace the battery immediately Remove the battery cover Noting the polarity replace the battery Install the battery cover anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412 11 7 Technical Specifications Typically within 20mW Cm 5 2dgt Accuracy whichever is greater in sunlight Additional temperature induced error 0 38W Cm C from 25 C Range 3999 uW cm 39 99MW cm Accuracy Attenuation lt 3 year UV Spectrum 290 nm to 390 nm Peak Sensitivity Wav
7. rchase or copy of the original invoice e Ifthe unit is out of warranty prepayment is required by Check Money Order or Credit Card Return all merchandise to Anaheim Scientific with pre paid shipping The flat rate repair charge for Non Warranty Service does not include return anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412 13 shipping Return shipping to locations in North American is included for Warranty Service For overnight shipments and non North American shipping fees please contact Anaheim Scientific Anaheim Scientific ATTN Service Repair 22820 Savi Ranch Parkway Yorba Linda CA 92887 www anaheimscientific com anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412 14 9 Limited Two Year Warranty Scientific warrants to the original purchaser that its products and the component parts thereof will be free from defects in workmanship and materials for a period of two years from date of purchase Anaheim Scientific will without charge repair or replace at its option defective product or component parts Returned product must be accompanied by proof of the purchase date in the form of a sales receipt To help us better serve you please complete the warranty registration for your new instrument via our website www anaheimscientific com Exclusions This warranty doe
8. s not apply in the event of misuse or abuse of the product or as a result of unauthorized alterations or repairs The warranty is void if the serial number is altered defaced or removed Anaheim Scientific shall not be liable for any consequential damages including without limitation damages resulting from loss of use Some states do not allow limitations of incidental or consequential damages So the above limitation or exclusion may not apply to you This warranty gives you specific rights and you may have other rights which vary from state to state anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412 15 anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412 16 ANAHEIM SCIENTIFIC 22820 Savi Ranch Parkway Yorba Linda CA 92887 www anaheimscientific com 2013 Anaheim Scientific anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 20130412