Portable Programming Device (PPD) Software
Contents
1. Info Firmware Version 1 08 Contig File Version 1 00 3 Connect Status Connected ALORS E LEI Pd0 0 AC O000 Port Configuration Contig File version 1 07 g Connect Status Mot Connected Ea t Settings ee Remote Port Settings Ethernet Port Settings Miscellaneous Port Settings Into Remote Port Settings Ethernet Port Settings Miscellaneous Port Settings Figure 3 5 2 Port Settings vid IMPORTANT If the HTC Bus Baud Rate is changed you must cycle the power on all controllers connected to this AC2000 otherwise HTC communications failure alarms will occur 3 5 3 Upgrade AC2000 Flash ROM Use of this feature is best accomplished using a stylus as the interface is not optimized for access using a finger on the touch screen The Upgrade Flash ROM screen contains two selections one to update the Flash Configuration file and the second to update the Boot Monitor file Select the appropriate binary file using the browse function and then press the Next button to start the upgrade operation Once the Flash Upgrade operation starts it will take several minutes to complete PPD Software 7 ROKE x Info Fiimware wersion 1 00 Contig File Version 1 07 Connect Status Wot Connected Upgrade FLASH ROM Config File wersion 1 07 Connect Status Mot Connected QP ee Flash Configuration File Upgrade FLASH ROM Boot Monitor File Description Flash Configuration File Boot Monitor File Into F
2. gt PENTAIR DigiTrace Portable Programming Device PPD Software INSTALLATION AND OPERATING INSTRUCTIONS Versions up to V1 0X PPD HAZ THERMAL MANAGEMENT SOLUTIONS EN DigiTracePPDsoftware IM H57402 04 13 1 24 CONTENTS MAT AVOUT Te Gl OU A T E E OEE E A TEE E E EE S EE teeciaesuens 3 LC SU SC CI an csaisuntamnonprivanourtnriewa medians T E A A E tumiernaanalnanton 3 User CSD ONGOING S seisis esanean aA ASAA AAR Ta A IREAS TRENERE ANA J See ANETE S E E A E E E AE T E E 5 T Ca UPO T erra n E E N E E E A E E E O antes 3 Pecon LOVON OW es earn un ee vapeeaienca usieednedn tiem Conon ents de unlnidanta iste de Uae nsmans ieee aeesneen tomiaNnedsR Nats 6 tal oys em FOUN SIN CIS ac eaccneanececcnalgeetshscanccndahoreanagoteanagnagncteasetsiernaiedssonsnd iara RER aia 6 E E 0 a A ene E E E T E I A E ee 6 1 3 Installing the PPD SOU WAP 6 cccsc cstscncdecencntondesanientalenacep asus ssasadonentneebndauaxthortdanienneiebiedbicdidereudorestiers 6 laost asta ling ACIVE VIG sas aE E eepe EAA E andes sa Gimeniniudccsatesinth Wedd wears Rrecct tenes 6 l 3 Establishing a Connection to Your PC vaseccccccerczaceudesecvasatscndewasPsaczaeseetneasaseneaneeeetniecedeasbecssoseete 7 1 3 3 Installing or Upgrading USING a New PU isissssisturssscizcatacncinnccnaacasaraintasaaesiassbcaawianaeigesiansbinagiies 8 1 3 4 Installing or Upgrading using an Existing PG cccccsdsccosnacatedeasesetessnccaanedaaneiedeensesecntesdvedeextasters 9 1 4 Uninstalling the SOM
3. IND depending on the type of PPD you have purchased 6 Select the folder for the specific PDA type for which you are installing the software for example DI 225 or Jett CE etc 7 Select the SETUP EXE entry and click OK to start THERMAL MANAGEMENT SOLUTIONS EN DigiTracePPDsoftware IM H57402 04 13 7 24 4 IMPORTANT You MUST install the correct version of PPD Software for the specific type of device that you are using The software will not operate if the wrong version is installed DigiTrace PPD Software InstallShield Wizard l x Welcome to the InstallShield Wizard for DigiT race PPD Software The InstallShield Wizard will install DigiT race PPD Software on your computer To continue click Next lt Back Figure 1 3 3 Installation Wizard Screen 1 3 3 Installing or Upgrading using a New PC The next few steps apply when your PC has never before been used to install or upgrade the PPD software Refer to the next section if you are using a PC that has previously been used to install or to upgrade a PPD s software Continuing from section 1 3 2 above perform the following steps 8 You will be prompted to enter your name and agree to the Microsoft License Agreement You must agree to continue the Installation process If you disagree the process will terminate 9 Select the Complete installation process and follow any on screen instructions DigiTrace PPD Software InstallShield
4. F High TSZ Alarm Low Load Current Alarm High Resistance Alarm Warning A Low TES Warning Contactor Count Warning Figure 3 4 9 HTC Alarms 3 4 9 Edit HTC Tag This screen allows you to edit the CM2000 CM2000 tag Enter a valid tag then press the OK button to save The tag must be 19 characters or less and valid characters include the following e AtoZ e atoz e Oto e 0 4 THERMAL MANAGEMENT SOLUTIONS EN DigiTracePPDsoftware IM H57402 04 13 20 24 Info Press edit to change the parameter below Press OK to save the change New Setting HTC Tag 794 7000 PPD Software Info Press edit to change the parameter below Press OK to save the change Hew Setting HTE Tag 794 00 1 Current Setting 794 7000 o fe Current Setting 794 001 Figure 3 4 10 Edit HTC Tag 3 5 TOOLS MENU The Tools menu screen provides access for configuration of the AC2000 communication ports upgrading the Flash ROM program memory saving AC2000 configuration to a disk file and Updating the AC2000 configuration from a disk file See the sections below for more information on how to use these functions Note that the functions in this menu are intended for advanced users The user interface is not optimized for use with a gloved finger so a stylus may be required to easily navigate through the mg Various parameters F IMPORTANT The AC2000 must be in CONFIG mode before you c
5. If you are editing a numeric parameter the Alpha mode keys will not allow you to enter alphabetic characters or special symbols You may use the UP and DOWN buttons to quickly increase or decrease a numeric value without using the keyboard THERMAL MANAGEMENT SOLUTIONS EN DigiTracePPDsoftware IM H57402 04 13 13 24 2 4 ONLINE HELP The PPD software includes an online help feature Access to this feature is best accomplished using a stylus as the interface is not optimized for access using a finger on the touch screen To access Help text press the symbol on the upper right hand corner of the display DigTrace PPD Software 3 fow The DigiTrace PPD Software is a DigTrace PPD So ae Windows CE based software utility designed to configure various E contents t Back all Topics EEB ees E The BigiTrace PPD Software is a a pee e e Windows CE based software utility DO0CM2000 Heat Trace Controlers designed to configure various DigiTrace The software also provides the user devices This version of the software Gnidia supports the AC 2000 Ungrade the AC 2000 firmware alarm communications card and A CM 2000 CM2000 Heat Trace Using Tools Controllers The software also provides SOOMUSE F the user with the ability to configure F Aser il KR 12 26 Pm Figure 2 4 1 Help Screen THERMAL MANAGEMENT SOLUTIONS EN DigiTracePPDsoftware IM H57402 04 13 14 24 SECTION III USING THE SOFTWARE WITH DIGITRACE T2000
6. WAV Ces ciceccicnestensectessatahdesosdinncdindecadserstesantandcoeeeasstdaiatdsdeediadinsasersinetatesestasnsaters 9 1 4 1 Removing the Software trom your PD Ais sccsccszecencsexatecnaceszcecesasducebecssianceidataseaeearegbedaverecienaanees 9 1 4 2 Removing the Software from your PC swicscsccactececesetevexvenerdonetdsaveneiversteeneiaues iagnverssetetaioaaeaes 10 Section l Sotware BASICS giccieyiaeicsnnossiurtninotninarpenaaudananseivinimeinnnnch EE aE EEEE EEE 11 2 1 Navigating the SoftWare secce lt creshradamnctsnssseieenstcadsasageeadtiesawteaindatexaidaxonetocsieaexudea danaeduieteedieeceaios 11 Vice Mes 616 E lt 1 10 E etn E E AA AA ETA EN A EA A E E 11 CP ENG E E E E E T EE 13 P THC e a E A A E E E E E 14 Section Ill Using the Software with DigiTrace T2000 SysStems cccccecceseeeceeeeeeeeeeaeeesaaeeeeeessaeeseaeeesaees 15 Ol POOF GS EA EA ET T E A AE AITES TT A TE T TS 15 o Fe E E E AE A E E AE E AA kes peatis asters LS 3 3 Connecting to an AG ZOO i aeoctenntsmercetecden tanssanhtasndeasendacereses EE EENEI ENN ETR AEN ONE EE Era EES 16 3 4 AC2000 and CM2000 CM2000 SUpport ceceecccccssccessscceeseecesseeessececseeecesseecesseseruesenneeensaes 16 SE COM USOC C ina traats E A A A EE AE T E 17 E 2S e a E TEE E A E A A E A T E neiaiareantt 17 OPS Deleie ATU sesoses Era E a E EE 18 OC A T a a EE E E A S 18 JAE OCU Ti iepen E E E E aS 19 Jo ON Ce ATG saeia e E E T E E niatiraneaneien 19 e AOAO E E e E E E ea wialmaunnener
7. ai Copyright 2003 Be Aaa wi Tyco Thermal Controls vee Thermal Controis i Version 1 00 15 Copyright 2003 Tyco Thermal Controls Version 1 00 15 start ey fea RH 5 07 AM Figure 2 1 1 Main Screen Set Jp Tools 2 2 PROGRAM SETUP Program setup Includes configuration of COM Port Settings and General Settings Info To edit a program setting select it from the list below then press Wext Program Setup ea zs General Settings PPD Software Info To edit a program setting select it from the list below then press Next Description General Settings Figure 2 2 1 Program Setup THERMAL MANAGEMENT SOLUTIONS EN DigiTracePPDsoftware IM H57402 04 13 11724 The COM Port Settings include the COM Port Baudrate Parity Stopbits Protocol Timeout and Retries parameters To edit the COM Port parameters press the Setup button on the main screen to display the Program Setup screen On this screen the COM Port Settings item is selected as the default Press the Next button to display the COM Port Settings screen You can use the Up or Down buttons to select the COM Port parameter to modify and use the OK button to save your changes To go back to the previous screen use the Back button The COM port settings must match the communications port settings on the target device to establish a connection with the PPD Info To edit a program setting select it PPD Software tom th
8. shall be void Pentair Thermal Management may freely assign this agreement and its rights and obligations thereunder to any third party 13 INVALID PROVISIONS If any of the provisions of this provisions Agreement are invalid under any applicable statute or rule of law they are to that extent deemed omitted Should you have any questions concerning this Agreement or if you desire to contact Pentair Thermal Management for any reason please write to Pentair Thermal Management 307 Constitution Drive Menlo Park California 94025 1164 U S A USER RESPONSIBILITIES The performance reliability and safety of your heat tracing system depend on proper design selection and installation The DigiTrace Portable Programming Device PPD Software will help you configure and monitor a system that meets your requirements but it is only a tool It assumes that your input is accurate that you are familiar with heat tracing system design and configuration and that you will ensure that all components of the heat tracing system are installed maintained and used as intended The configuration of the DigiTrace Portable Programming Device PPD Software should be reviewed by a knowledgeable engineer to ensure it iS appropriate for your application Additional information relating to safety design and installation is contained in Design Guides Installation Manuals Data Sheets and other literature available from Pentair Thermal Management Be sure to c
9. 2000 Configuration function will update the AC2000 configuration settings from a previously saved configuration file of your choice Select the file using the browse function THERMAL MANAGEMENT SOLUTIONS EN DigiTracePPDsoftware IM H57402 04 13 23 24 APPENDIX A TROUBLESHOOTING A 1 COMMUNICATION ERROR Modbus Timeout If the PPD software reports a Modbus Timeout error verify the following 1 The cable from the PPD to the target device AC2000 etc is properly connected F 2 The communications parameters for the PPD are set to match the target device IMPORTANT If you are upgrading the Flash ROM and you get Modbus timeout try increasing the number of retries allowed If upgrading an AC2000 with an Ethernet port connection try disconnecting the Ethernet cable to the AC2000 during the upgrade process gt PENTAIR WWW THERMAL PENTAIR COM NORTH AMERICA EUROPE MIDDLE EAST AFRICA ASIA PACIFIC LATIN AMERICA Tel 1 800 545 6258 Tel 32 16 213 511 Tel 86 21 2412 1688 Tel 55 11 2588 1400 Fax 1 800 527 5703 Fax 32 16 213 603 Fax 86 21 5426 2917 Fax 95 11 2588 1410 Tel 1 650 216 1526 thermal info pentair com cn thermal info pentair com thermal info pentair com Fax 1 650 474 7215 thermal info pentair com Pentair and Digilrace are owned by Pentair or its global affiliates All other trademarks are the property of their respective owners Pentair reserves the right to change specifications without prior notice
10. 2003 2013 Pentair THERMAL MANAGEMENT SOLUTIONS EN DigiTracePPDsoftware IM H57402 04 13 24 24
11. ARE BASICS 2 1 NAVIGATING THE SOFTWARE When you launch the PPD software you will see the main screen See Figure 2 1 1 The screen may be set up in landscape or portrait mode depending on the type of PDA you are using This document provides examples of each type of display throughout this document The functionality of the PPD software Is the same for both landscape and portrait mode The main screen includes version and copyright information as well as four navigation buttons The function of these four buttons will change depending on the feature you are using On the main screen these buttons are Connect Tools Exit and Setup Using these four buttons you can navigate and control all functions of the PPD software Pressing and holding the Up and Down buttons will cause the selection cursor to move up or down repeatedly or to increment decrement a numeric field if it one is being edited Note also that the small square blocks on the lower right hand side of the screen serve as a reminder to the user of the current menu level relative to the main screen The deeper the menu level the more blocks will be displayed The following screens are considered main screens Device Selection Tools and Setup C4 IMPORTANT When the software is run for the first time you need to edit the program setup see Section 2 2 that follows PPD Software OK PPD Software D igiTra ce DigiTrace lie P P D Connect Software Software
12. C GCC Alarms Edit GCC Tag Figure 3 4 2 GCC Operations Into Tag 4C2000PLU5 Address 1 Modelver 4Ace000 1 42 Alarms 1 GCC Configuration Description Alarm Settings Global Alarm Priorities Settings Load Shedding Settings Miscellaneous Settings Figure 3 4 3 GCC Configuration 3 4 2 Install HTC peo sorware AEH Info Tag 4C2000PLUS Address 1 Model Ver 4C2000 1 43 Alarms 2 GCC Operations Description mT re SEES Install HTC Delete HTC GCC Alarms Edit GCC Tag Down Aser ETS 12140 M IMPORTANT Some parameters are dependent on other settings The software will automatically hide selections that should not be available PPD Software OK Info Tag AC2000PLUS Address 1 Modelyer 4C2000 1 435 Alarms 2 GCC Configuration Alarm Settings Global Alarm Priorities Settings Load Shedding Settings Miscellaneous Settings Down Aser E E3 12 14 pm This screen allows you to install an HTC into an AC2000 Select the TAG or ADDRESS fields using the Select button and edit the selected parameter by pressing the Edit button Enter an appropriate tag and address for the new HIC then press the Install button The tag must be 19 characters or less and the valid address range Is 1 to 16777216 PPD Software Info Enter the Tag and Address for the new controller by selecting the parameter and pressing edit Press OK to save the change Hew HTC n Addr
13. Configuration HTE temperature settings Temperature Alarm Settings Electrical Settings Other Alarm Settings Miscellaneous Settings Modelyer CM2000 3 18 Alarms 1 HTE Configuration Description Temperature Alarm Settings Electrical Settings Other Alarm Settings Miscellaneous Settings IJ p B own Aser JE S 1217 Pu e Figure 3 4 7 HTC Configuration F IMPORTANT Some parameters are dependent on other settings The software will automatically hide selections that should not be available 3 4 7 Monitor HTC The HTC Monitor screen includes the Temperature Readings Electrical Readings Maintenance Readings Reset Max Min Values the Test Trace feature and the Set Monitor Interval parameter To monitor HTC data use the Up or Down buttons to select Temperature Readings Electrical Readings or Maintenance Readings Once you have chosen one of these screens the software will automatically scan the HTC and refresh the screen once every Monitor Scan interval The default Monitor Scan interval is 5 seconds You can edit the Monitor Scan Interval with the Set Monitor Interval option THERMAL MANAGEMENT SOLUTIONS EN DigiTracePPDsoftware IM H57402 04 13 19 24 The Reset Max Min Values selection includes Reset Max Min Temperatures Reset Hours in Use Reset Power Accumulator and Reset Contactor Count functions For each of these functions the software will prompt you to confirm the choice before it executes the comma
14. SYSTEMS 3 1 FEATURES This version of the PPD software will allow you to perform the following for each of the products listed below AC2000 Alarm Communications Card 1 Setup the parameters for each of the three communications ports 2 Save and Restore the communications port configurations from to a disk file 3 Upgrade the AC2000 with the latest version of firmware 4 Edit AC2000 configuration parameters 5 Install Uninstall a CM2000 CM2000 to from an AC2000 6 Edit the tag of an AC2000 7 View and Reset alarms in an AC2000 CM2000 and CM2000 Heat Tracing Controllers 1 Edit CM2000 CM2000 configuration parameters 2 View and reset CM2000 CM2000 maintenance data 3 Edit the tag of a CM2000 CM2000 4 View and Reset alarms in a CM2000 CM2000 5 Monitor CM2000 CM2000 parameters in real time 4 id IMPORTANT The PPD and PPD Software are NOT compatible with older T2000 systems using an AC2000 Alarm Communications Interface card For information on how to upgrade an existing system contact your local Pentair Thermal Management representative 3 2 PREPARATION Before you begin make sure your PPD is properly connected to the DigiTrace AC2000 using one of the communications cables provided with the PPD kit You may connect the PPD to the local port located on the front of the AC2000 card or to the chassis mounted communications connector on a T2000 control panel ca IMPORTANT The AC2000 may be set to either CONFIG or R
15. UN mode You must change the dip switch setting on the AC2000 to place the unit into configuration CONFIG mode After you have saved the configuration changes you must change the dip switch setting back to place the AC2000 into RUN mode See the DigiTrace T2000 User Manual for more information on AC2000 dip switch settings THERMAL MANAGEMENT SOLUTIONS EN DigiTracePPDsoftware IM H57402 04 13 15 24 3 3 CONNECTING TO AN AC2000 Before you can configure an AC2000 and or CM2000 CM2000 you must use the Connect button and enter the communications address of the AC2000 Once the connection is established you can perform configuration changes view and reset alarms add remove HTCs view maintenance data perform maintenance functions and edit the device s tag The following Section will provide more detailed information on how to use these functions Pro software BOA Info To establish a connection please enter the Base Address of the device then press OK to continue PPD Software Info To establish a connection please enter the Base Address of the device then press OK to continue Edit a Figure 3 3 1 Establish a Connection IMPORTANT The AC2000 must be in RUN mode for the connection to be successful 3 4 AC2000 AND CM2000 CM2000 SUPPORT Once a successful connection to the AC2000 has been established the Device Selection screen will be displayed This screen will show at least one dev
16. Wizard Setup Type Select the setup type to install Please select a setup type All program features will be installed Requires the most disk space C Custom Select which program features you want installed Recommended for advanced users InstallShield lt Back Cancel Figure 1 3 4 Complete Installation Selection 10 If your PDA already has a version of the PPD software installed on it the installation process will detect this and you may be asked to confirm that you want to reinstall or upgrade the software Answer yes to proceed 11 Answer yes when prompted to install the software into the default directory folder 12 You will now be asked to check the mobile device PDA to perform any additional steps If the PPD software has been previously installed on the PDA you may be asked to confirm that you want to reinstall or upgrade the software Answer yes to proceed 13 Once complete return to the PC screen and complete the installation process by following any additional instructions THERMAL MANAGEMENT SOLUTIONS EN DigiTracePPDsoftware IM H57402 04 13 8 24 1 3 4 Installing or Upgrading using an Existing PC The next few steps apply when your PC has previously been used to install or upgrade the PPD software Refer to the previous section if you are using a PC that has never before been used to install or to upgrade a PPD s software Continuing from section 1 3 2 above perform the following
17. an use the tools menu Refer to the AC2000 User Manual for detailed instructions on how to place it into CONFIG mode 3 5 1 Using Tools The Tools screen includes AC2000 Port Configuration Upgrade Flash ROM Save AC2000 Configuration and Update AC2000 Configuration function items PPD Software PPD Software mmaa Info Firmware Version 1 08 Firmware version 1 00 Config File Version 1 00 Connect Status Connected Contig File version 1 07 Connect Status Not Connected 4C2000 Port Configuration Upgrade Flash ROM Save 4C2000 Configuration Update AC2000 Configuration Upgrade Flash ROM Save 4C2000 Configuration Update 4C2000 Configuration B own Aon SP ES 22 E Figure 3 5 1 Tools Menu 4 F IMPORTANT The communications parameters for an AC2000 in CONFIG mode are fixed at 38400 Baud No Parity 1 Stopbit and RTU protocol The PPD software will dynamically set its communications parameters to match when the Tools button is pressed 3 5 2 AC2000 Port Configuration The AC2000 has three communications ports a Remote Port a Local Port and an Ethernet port Each communications port must be setup appropriately in order for upstream software such as DigiTrace Supervisor to communicate to it THERMAL MANAGEMENT SOLUTIONS EN DigiTracePPDsoftware IM H57402 04 13 21 24 Each port has its own independent set of communications parameters Consult the AC2000 User Manual for details regarding these parameters
18. e list below then press Next Into To edit a program setting select it COM Port Settings from the list below then press Next COM Port Settings Protocol Baud Rate Timeout Parity Stopbits Protocol Figure 2 2 2 Communications Port Settings The General Settings include the Language and Temperature Units parameters This version of the PPD software only supports an English language display Temperature units may be displayed in degrees Fahrenheit or Celsius PPD Software OK Info PPD Software To edit a program setting select it from the list below then press Next Info To edit a program setting select it from the list below then press Next General Settings General Settings Temperature Units Fahrenheit ee 6 Figure 2 2 3 General Settings THERMAL MANAGEMENT SOLUTIONS EN DigiTracePPDsoftware IM H57402 04 13 12724 2 3 EDITING A PARAMETER Editing of numeric and alpha numeric parameters is supported by the PPD software using a pop up multi function keyboard D Device Acres E Add 1 PPD Software i _ _ EZ ee lef a es lef a es he d ed he d ed ee a g cu Figure 2 3 1 Pop up Keyboard The keyboard provides buttons that are large enough to be pressed by a gloved finger and supports both numeric and alphabetic character entry Four buttons Num Alpha 1 Alpha 2 and Alpha 3 are located below the main keys allowing the user to define the function of each of the twelve k
19. e user should refer to the documentation for the specific product being used for detailed information about the products use The PPD kit includes the following items e Industrial PDA Personal Digital Assistant charger and user guide e Synchronization cable to connect the PDA to your Personal Computer PC e Set of communications cables to allow the PDA to be connected to various Digilrace products AC2000 etc e Software CD e PPD Software User Manual For specific details regarding the use maintenance and repair of the particular PDA included with the PPD kit refer to the PDA Manufacturer s User Guide To effectively use the software you must have the following minimum configuration e Pocket PC running Windows CE 3 0 or higher e Intel StrongArm or XScale processor e At least 2 megabytes of free memory space e 1 available serial or USB port e The appropriate serial or USB interface cable kit e While the software may run on various 3rd party devices it has been specifically tested to operate with the Pentair Thermal Management PPD IND and PPD HAZ Portable Programming Devices and accessories The PPD software is designed to run on a Windows CE device See Section 1 1 System Requirements for supported devices If you have purchased a complete PPD IND or PPD HAZ kit from an authorized Pentair Thermal Management distributor the PPD software will have been pre installed on the PDA at the Factory You must fully charge y
20. eee 19 Fd Pall Will ea r EE S cat nia pdand tertaayshedde Steps ESE E E 20 SEE EG AG eea E E E EE EE 20 COREE e E E E EE E E E E I E 21 Do WI SUV TOOLS eesnime E iiie a E 21 3 5 2 AC 2000 POrt C OM MOU ACION sascienacseenssidasendsdesceninsaeseetoneetdsesuasceverececsdd lt cedeaeduauceieseede ALANEN ONNEN Ze 3 9 3 Upgrade AC 2000S Flash ROM sxcicine cccisascecaneactuzaccedeagusetcuvesOseeedonauasantethocsasassenseeeenatesesdanenbere Le 3 9 4 Save ACZU00 Config ratiOM sscsscscenccenrasancateotateteassaagdacaneencceaaniqeneianetentaiasiaeaanideanieeseaneeiaaeze 23 3 0 0 Update ACZ0UU Contigurat oN seide EE E EEEE EENEN 23 Appendik A MOUDE ShNOOTING Rene ene eet nienia ae aa en eer eee eee 24 ATC Ola geet tion ETOT ereere ie aee eee EE oa A e RE Eni 24 THERMAL MANAGEMENT SOLUTIONS EN DigiTracePPDsoftware IM H57402 04 13 2 24 VITAL INFORMATION C4 IMPORTANT All information including illustrations is believed to be reliable Users however should independently evaluate the suitability of each product for their particular application Pentair Thermal Management makes no warranties as to the accuracy or completeness of the information and disclaims any liability regarding its use Pentair Thermal Management only obligations are those in the Pentair Thermal Management Standard Terms and Conditions of Sale for this product and in no case will Pentair Thermal Management or its distributors be liable for any incidental indirect or consequ
21. een the parties with respect to the DigiTrace Portable Programming Device PPD Software and its use and may not be varied except by a writing signed by an officer of Pentair Thermal Management You agree that you may not rely on any representations concerning the DigiTrace Portable Programming Device PPD Software to the extent they vary from this Agreement and such representations if any will neither add to nor vary the terms of this Agreement 7 CHOICE OF LAWS This Agreement is governed by the laws of the State of California and the United States including U S Copyright Laws 10 EXPORT LAWS The DigiTrace Portable Programming Device PPD Software may require a license from the U S Department of Commerce or other governmental agency before it may be exported The term export includes many acts such as transferring the DigiTrace Portable Programming Device PPD Software to a foreign citizen within the United States in addition to sending or taking the DigiTrace Portable Programming Device PPD Software outside the United States You agree to ascertain the necessary licensing procedures and obtain any required licenses before exporting the DigiTrace Portable Programming Device PPD Software You also agree to indemnify Pentair Thermal Management and assume all financial responsibility for any losses it may suffer if you do not comply with this paragraph ha Government Restricted Rights User acknowledges that the DigiTrace Portab
22. ential damages arising from the sale resale use or misuse of the product Specifications are subject to change without notice In addition Pentair Thermal Management reserves the right to make changes without notification to Buyer to processing or materials that do not affect compliance with any applicable specification LICENSE AGREEMENT DigiTrace Portable Programming Device PPD Software License Agreement This agreement is a legal agreement between you the end user and Pentair Thermal Management LLC Pentair Thermal Management By installing or otherwise accessing this program you are agreeing to become bound by the terms of this agreement If you do not agree to the terms of this agreement do not install or access this program If installing or otherwise accessing this program by opening a sealed disk package promptly return the unopened disk package and the other items including written materials or other containers to the place where you obtained them 1 GRANT OF LICENSE The DigiTrace Portable Programming Device PPD Software the Software is licensed not sold to you for use only under the terms of this Agreement and Pentair Thermal Management reserves any rights not expressly granted to you Pentair Thermal Management grants to you the end user the right to use this copy including written materials if any of the Software on a single computer at the location company and address to which Pentair Th
23. ermal Management issued this copy of the DigiTrace Portable Programming Device PPD Software The Software is owned by Pentair Thermal Management LLC and is protected by United States copyright laws and international treaty provisions You agree not to alter merge duplicate distribute decompile or reverse engineer create derivative works copy for use on any other computer or at any other location or otherwise make this program available to any person or entity outside this location All copies made by you are subject to the terms and conditions of this Agreement 2 OTHER RESTRICTIONS 1 You may not sublicense rent or lease the DigiTrace Portable Programming Device PPD Software to anyone 2 You agree to notify Pentair Thermal Management promptly if bugs or seemingly incorrect or anomalous behavior is discovered when using the Software 3 You agree that the DigiTrace Portable Programming Device PPD Software including written materials if any and all copies in whole or in part will be destroyed or returned to Pentair Thermal Management at the written request of the Pentair Thermal Management Product Manager 4 By installing or otherwise accessing the DigilTrace Portable Programming Device PPD Software you acknowledge that you have read and understood Pentair Thermal Management Disclaimer of Warranty and Limitation of Liability set forth below 5 You agree to use reasonable efforts to protect against the unauthori
24. ess i Figure 3 4 3 Install an HTC HERMAL MANAGEMENT SOLUTIONS EN DigiTracePPDsoftware IM H57402 04 13 Info Enter the Tag and Address for the new controller by selecting the parameter and pressing edit Press OK to save the change 17 24 3 4 3 Delete HTC This screen allows you to delete an HTC from the AC2000 Use the Up and Down buttons to select the HTC Press the Delete button to delete it After you press the Delete button the software will prompt you to confirm the deletion If you select Yes the HTC will be permanently removed from the AC2000 installed HTC list PPD Software 2 OK PPD Software Info Info Tag AC2000PLUS Tag 4C2000PLU5 Address 1 ahea 4 Model Ver AC2000 1 43 Alarms 2 Modeler 4C2000 1 42 Alarms 1 Delete Bout SP S 12157 f Figure 3 4 4 Delete an HTC 3 4 4 GCC Alarms This screen displays all active alarms for the AC2000 and will refresh automatically every 5 seconds To view HTC alarms please see Section 3 4 8 HTC Alarms To reset a GCC alarm use the Up and Down buttons to select an alarm and then press the Reset button The software will display a prompt that allows you the option to reset the selected alarm reset all alarms or cancel the operation Once an alarm is reset the alarm is removed from the GCC Alarms screen PPD Software Into Tag 4C2000PLUS Address 1 Modeler 4C2000 1 42 Alarms 1 PPD Software OK Info Tag AC2000PLUS Addres
25. eys in the keyboard as follows NUM Key This key shows the default state and allows you to enter the numbers 0 through 9 and a decimal point into the parameter that is being edited When this mode is selected the large text on each key will represent a specific character as defined by the first character in the text along the top of each key ALPHA 1 Key When this key is pressed you will be allowed to enter the characters A D G J M P S V Y and into the parameter that is being edited When this mode is selected the large text on each key will represent a specific character as defined by the second character in the text along the top of each key ALPHA 2 Key When this key is pressed you will be allowed to enter the characters B E H K N Q T W Z J and into the parameter that is being edited When this mode is selected the large text on each key will represent a specific character as defined by the third character in the text along the top of each key ALPHA 3 Key When this key is pressed you will be allowed to enter the characters C F I L O R U X lt space gt and into the parameter that is being edited When this mode is selected the large text on each key will represent a specific character as defined by the fourth character in the text along the top of each key S id IMPORTANT The Backspace key is available in all four keyboard modes to allow you to clear an entry
26. ice the AC2000 at the top of the list Any installed CM2000 CM2000 controllers will be displayed after the AC2000 Use the Up or Down buttons to select the device upon which you wish to perform operations The following Group Communications Controller GCC operations are available when the AC2000 is selected 1 Configure GCC 2 Install HTC 3 Delete HTC 4 GCC Alarms 5 Edit GCC Tag The following HTC operations are available when a CM2000 CM2000 is selected 1 Configure HTC 2 Monitor HTC 3 HTC Alarms 4 Edit HTC Tag Info To configure a device select it from the Device Selection List then press Next Device Selection PPD Software Info To configure a device select it from the Device Selection List then press Next Device Selection 794 001 g 794 002 Figure 3 4 1 Device Selection THERMAL MANAGEMENT SOLUTIONS EN DigiTracePPDsoftware IM H57402 04 13 16724 T 3 4 1 Configure GCC The GCC Configuration screen includes Alarm Settings Global Alarm Priorities Settings Load Shedding Settings and Miscellaneous Settings Each of these Settings contains a set of parameters that you can edit Use the Up and Down buttons to choose the desired Setting and the Next button to select it After you ve made your changes use the OK button to save them PPD Software Into Tag 4C2000PLU5 Address 1 Modeler 4C2000 1 42 Alarms 1 GCC Operations Description Install HTC Delete HT
27. ies either express implied or statutory including but not limited to any warranty of merchantability or fitness for a particular purpose even if pentair thermal management has been advised of such purpose This agreement gives you specific legal rights Some states or countries do not allow the exclusion of warranties so the above exclusion may not apply to you 6 LIMITATION OF LIABILITY Pentair thermal management shall not be liable for any loss damage or delay during shipment or for any loss of profits loss of use interruption of business nor for indirect special incidental or consequential damages of any kind whatever under this agreement or otherwise whether or not pentair thermal management has been advised of the possibility of such damages 7 TERMINATION The license granted herein will automatically terminate without notice from Pentair Thermal Management if you fail to comply with any term or condition of this Agreement You agree upon such termination to remove the DigiTrace Portable Programming Device PPD Software from any memory and or storage media or device and to return the DigiTrace Portable Programming Device PPD Software including all media and written materials or destroy the same and certify such destruction to Pentair Thermal Management along with any backup or other copies in your possession 8 COMPLETE AGREEMENT MODIFICATION IN WRITING This Agreement constitutes the sole and complete understanding betw
28. irmware Version 1 00 D D A Aser la Ra 2 10 AM Figure 3 5 3 Upgrade Flash ROM M IMPORTANT Do not cancel the upgrade operation while it is in process or the AC2000 will likely be left in an inoperable state THERMAL MANAGEMENT SOLUTIONS EN DigiTracePPDsoftware IM H57402 04 13 22 24 Save AS z on x AA My Documents BA charset exe Hellace ex H Program Files a CML DAT BA my StackDk Recycled fl Com Controller Utilities exe BA ShowCurse Temp EA com Controller Utility exe BA siroplediq e a BA digtest exe BA StackDialoe a Type Jac2o00 Config CFG Internal Disk My Documents NETHVORE J Program Files Type ac2000 Binary EXE D OwA Ar E ES aime E Figure 3 5 4 Browse for a File 3 5 4 Save AC2000 Configuration Use of this feature is best accomplished using a stylus as the interface is not optimized for access using a finger on the touch screen The Save AC2000 Configuration function will save the current AC2000 configuration settings communications port settings installed HTC list etc to a file You may specify the location to save the file using the browse function The default file name is CONFIG CFG although you may change this to any valid file name that you choose 3 5 5 Update AC2000 Configuration Use of this feature is best accomplished using a stylus as the interface is not optimized for access using a finger on the touch screen The Update AC
29. le Programming Device PPD Software has been developed at private expense and is provided with Restricted Rights Use duplication or disclosure by the Government is subject to restrictions as set forth in subparagraph b 3 and paragraph c of the Rights in Technical Data clause at 48 C F R 252 227 7013 or subparagraphs c 1 and 2 of the Commercial Computer Software Restricted Rights clause at 48 C F R 52 227 19 as applicable This provision applies to the DigiTrace Portable Programming Device PPD THERMAL MANAGEMENT SOLUTIONS EN DigiTracePPDsoftware IM H57402 04 13 4 24 Software acquired directly or indirectly by or on behalf of any government The Digilrace Portable Programming Device PPD Software is a commercial product licensed on the open market at market prices and was developed entirely at private expense and without the use of any government funds Any use modification reproduction release performance display or disclosure of the DigiTrace Portable Programming Device PPD Software by any government shall be governed solely by the terms of this Agreement and shall be prohibited except to the extent expressly permitted by the terms of this Agreement and no license to the DigiTrace Portable Programming Device PPD Software is granted to any government requiring different terms iz ASSIGNMENT You may neither assign any right nor delegate any obligation under this Agreement and attempted assignment or delegation
30. nd The Test Trace Selection can be used to force the HTC output on for a number of seconds the Test Trace period In this screen use the Up or Down buttons to set the test trace period then press the OK button to initiate the test trace feature PPD Software OK Info Tag 794 7000 Address 7000 Model Ver CM2000 3 19 Alarms 4 HTC Monitor ETETEN E Electrical Readings Maintenance Readings Reset Max Min Values Test Trace Set Monitor Interval PPD Software Into Tag 794 001 Address 2001 Modeler CM2000 3 18 Alarms 1 Description Temperature Readings Electrical Readings Maintenance Readings Reset Max Min values Test Trace Set Monitor Interval Down fon sp 9 2m a Figure 3 4 8 Monitor HTC 3 4 8 HTC Alarms This screen displays all active alarms for a CM2000 CM2000 and will refresh automatically every 5 seconds To view GCC alarms see Section 3 4 4 GCC Alarms To reset an HTC alarm use the Up or Down buttons to select an alarm then press the Reset button The software will display a prompt that allows you the option to reset the selected alarm reset all alarms or cancel the operation Once an alarm Is reset the alarm Is removed from the HTC Alarms screen PPD Software OK Info PPD Software r Tag 794 7000 Address 7000 Info Modelyer CM2000 3 19 Alarms 4 Tag 794 001 Address 2001 Modeler CM2000 3 18 Alarms 1 SesGi GMD oes HTC Alarms Description
31. ns THERMAL MANAGEMENT SOLUTIONS EN DigiTracePPDsoftware IM H57402 04 13 9 24 1 4 UNINSTALLING THE SOFTWARE Use of this feature is best accomplished using a stylus as the interface is not optimized for access using a finger on the touch screen When the PPD software is installed a copy is placed on your PC s hard drive and a copy is written directly into the PDA s memory 1 4 1 Removing the Software from your PDA To uninstall the software on the PDA 1 Use the Windows CE Start button to navigate to the Pentair Thermal Management folder Program Pentair Thermal Management 2 Select Uninstall PPD to uninstall the PPD software 3 Follow the instructions on the screen Ere Ean vew Ge jel JAdaress Program Files v Slee Click the Unistall button to uninstall DigiTrace PPD Click the Unistall button to uninstall DigiTrace PPD Software from the CE Software from the CE device Bse GF 4 57 Pm aa Fane Figure 1 4 1 Uninstall PPD Software 1 4 2 Removing the Software from your PC To uninstall the software from your PC 1 Use the Windows Start button to navigate to the Control Panel 2 Select Add or Remove Programs 3 Select the DigiTrace PPD Software entry in the list 4 Select the Change Remove button to uninstall the PPD software 5 Follow the instructions on the screen THERMAL MANAGEMENT SOLUTIONS EN DigiTracePPDsoftware IM H57402 04 13 10724 SECTION II SOFTW
32. onsult these documents as needed SAFETY WARNINGS There are important safety warnings shipped with our products and printed in our literature Be sure to read and follow them to reduce the risk of fire shock or personal injury If you have any questions contact you local Representative or Pentair Thermal Management directly TECHNICAL SUPPORT Local Representatives Contact your local Pentair Thermal Management representative for help For the most up to date and complete listing go to www thermal pentair com click Heating gt Customer Support select your region click Go choose an application enter your postal code if prompted and click Find Contact information for your local representative will appear THERMAL MANAGEMENT SOLUTIONS EN DigiTracePPDsoftware IM H57402 04 13 5 24 SECTION I OVERVIEW 1 1 SYSTEM REQUIREMENTS 1 2 INITIAL SETUP The Portable Programming Device PPD Software is a Windows CE based software utility designed to configure various DigiTrace devices This version of the software supports the following products e AC2000 Alarm Communications Interface e CM2000 and CM2000 Heat Tracing Controllers The software provides several features to help you configure and maintain your DigiTrace devices This document is not intended to provide a detailed explanation of the specific features of each product but rather to show the user how to access various parameters within the devices using the PPD software Th
33. our PDA prior to initial use follow the Manufacturer s instructions in the PDA s User Guide for more details 1 3 INSTALLING THE PPD SOFTWARE If the PPD software has not been installed on your CE device or you wish to upgrade an existing version of the software to a newer version follow the steps below 1 3 1 Installing ActiveSync To load the PPD software into a compatible device or to update an existing copy you must establish a connection between the device and a desktop computer that contains Microsoft s ActiveSync software Before you run the software installation you must successfully connect your PC to the Windows CE device using the ActiveSync software If you do not have ActiveSync installed on your computer you can obtain a copy from the Microsoft Website by accessing the following link www microsoft com downloads search asp searching on ActiveSync and downloading the latest version Follow the setup instructions to install ActiveSync onto your PC THERMAL MANAGEMENT SOLUTIONS EN DigiTracePPDsoftware IM H57402 04 13 6 24 1 3 2 Establishing a Connection to Your PC To install the PPD software connect the PDA to your computer using the cable provided with your PPD kit and perform the following steps 1 Establish a connection with your PC Some models of PDA such as the PPD HAZ DI 225 will automatically initiate the communications when you connect the cable Other types such as the PPD IND Jett CE may require
34. s 1 Model Ver AC2000 1 43 Alarms 1 F Configuration Error Alarm Description Alarm Queue 80 Full Warning AY Alarm Queue Full Warning EE Figure 3 4 5 GCC Alarms Aser E E3 12 16 pm THERMAL MANAGEMENT SOLUTIONS EN DigiTracePPDsoftware IM H57402 04 13 18 24 3 4 5 Edit GCC Tag This screen allows you to edit the AC2000 tag Enter a valid tag then press the OK button to save The tag must be 19 characters or less and valid characters include the following e AtoZ e atoz e Qto9 e 0 4 Info Press edit to change the parameter below Press OK to save the change New Setting GCC Tag Ec2o00PLuS PPD Software Info Press edit to change the parameter below Press OK to save the Hew Setting AC2000RLUS Cancel Current Setting m ACZO000PLUS Figure 3 4 6 Edit GCC Tag Current Setting AC2000PLUS 3 4 6 Configure HTC The HTC Configuration screen includes the HTC Temperature Settings Temperature Alarm Settings Electrical Settings Other Temperature Settings and Miscellaneous Settings Each of these selections contains a set of parameters that you can edit You can use the Up and Down buttons to choose the desired setting and the Next button to select it After you ve made changes to a parameter use the OK button to save the changes kini 7000 ag i aa Address 7000 aa Ta Model Ver CM2000 3 19 Alarms 4 ress PPD Software HTC
35. steps 8 Select the Repair installation process and follow any on screen instructions This will reinstall all program components that were installed by a previous setup DigiTrace PPD Software InstallShield Wizard x Welcome Modify repair or remove the program Welcome to the DigiT race PPD Software Setup Maintenance program This program lets you modify the current installation Click one of the options below C Modify Select new program components to add or select currently installed components to remove SF Reinstall all program components installed by the previous setup C Remove E Remove all installed components InstallShield Cancel Figure 1 3 5 Selection of Repair Process 9 If your PDA already has a version of the PPD software installed on it the installation process will detect this and you may be asked to confirm that you want to reinstall or upgrade the software Answer yes to proceed 10 Answer yes when prompted to install the software into the default directory folder 11 You will now be asked to check the mobile device PDA to perform any additional steps If the PPD software has been previously installed on the PDA you may be asked to confirm that you want to reinstall or upgrade the software Answer yes to proceed 12 Once complete return to the PC screen and complete the installation process by following any additional instructio
36. that you manually initiate communications from the PDA by running a connection utility Refer to the user manual provided with your PDA for detailed instructions 2 Once a connection has been made you may be asked whether you wish to create a PC to PDA partnership This type of synchronizing connection is not required but may be set up if you desire However usually this question is answered with a no You should now be connected as a Guest New Partnership Set Up a Partnership joe z Before you can synchronize information between your mobile device and this computer you must set up a4 partnership between them Would you like to set up a partnership C Yes Set up a partnership so that can synchronize information between my device and this computer don t want to synchronize information Set up my device as 4 quest so that can copy or move information between my device and this computer Figure 1 3 1 ActiveSync Connection Type Selection Microsoft ActiveSync IOl x File wiew Tools Help STG Stop Guest Connected Information Type Status Figure 1 3 2 Connected to ActiveSync as a Guest 3 Next insert the CD labeled DigiTrace Portable Programming Device PPD Software into the computer s CD ROM drive 4 Click the Start button select Run and then click on Browse 5 Select the CD ROM drive and navigate to the appropriate PPD folder PPD HAZ or PPD
37. zed copying and use the DigiTrace Portable Programming Device PPD Software by others THERMAL MANAGEMENT SOLUTIONS EN DigiTracePPDsoftware IM H57402 04 13 3 24 3 DISCLAIMER OF WARRANTY The digitrace portable programming device ppd software and accompanying written materials are provided as is without warranty of any kind The entire risk as to the results and performance of the digitrace portable programming device ppd software is assumed by you Pentair thermal management does not warrant that the functions contained in the software will meet your requirements or that the operation of the software will be uninterrupted or error free or that program defects will be corrected 4 LIMITED WARRANTY MEDIA The medium on which the program is encoded is warranted to be free from defects in material and workmanship under normal use for a period of sixty 60 days from the date of delivery to you as evidenced by a copy of your receipt Although pentair thermal management believes the media and the program to be free of viruses the medium and the program are not warranted to be virus free Pentair thermal management liability and your exclusive remedy if the medium is defective or includes any virus shall be prompt replacement of the medium with a new digitrace portable programming device ppd software pre encoded disc D EXCLUSION OF ALL OTHER WARRANTIES Except as expressly provided above pentair thermal management disclaims all warrant