Home

Installation Guide & User Manual

image

Contents

1. Installation Guide amp User Manual FR1300 Version 1 0 1 Date November 2014 Contents 1 Device Installation gt 21 ne gt 2 Work Principle gt 3 Other Functions gt A Verify Mode sashan 665 gt 5 List of Parameters gt Zoe p Coes cee a ee et A gt 9 1 Device Installation fon x 1 Remove the screw on the bottom of device 4 Fix the device to the back cover laa laa lag La ll 2 Take away the 3 Fix the back cover on back cover the wall according to the mounting paper i 5 Fix the screw se 2 Work Principle 1 Connection with Control Panel 0 4U0D ssasoy peaovueapy Less than 9 Readers can be connected with the Control Panel at present Access Control Panel 2 Connection with Standalone Access Control FR1300 Terminal s LGND 485 A ae IBELL LTXD j IBELL _USB Standalone Access Control 3 The terminal definition table of Reader remaners rame 3 Other Functions 1 Reset Switch If the device does not work properly because of misoperation or other abnormalities you can use Reset function Operation Remove the black rubber cap then st
2. turns red and the buzzer makes Non privileged three short beeps Press to input The indicator turns off and the buzzer makes password a long beep lr The indicator turns green three times when a A verify mode is finished i ila Var verify mode is finished the indicator turns and then into next green three times and then into next verification SARS i na verification when in combined verification The inputted user ID or The indicator turns off and the buzzer makes password is valid a long beep User ID or password is inputted and press to exit verification The indicator turns red the buzzer makes two Incorret verify mode short beeps and then makes a long beep Data transmission The indicator turns red the buzzer makes a abnormally short beep and then makes a long beep The indicator turns red the buzzer makes four The indicator turns red and the buzzer makes two short beeps Communication failed short beeps Validation steps 1 When the reader connected with the access control panel it is in verification state 2 Start user verification The reader supports fifteen Verify modes only card only fingerprint card and fingerprint card or fingerprint and so on Verify modes are as the follows Description Card Fingerprint and Password Press and then input duress password Fourth way press to confirm at last Onl Press finger for verification only Fingerprint Only
3. User ID Input user ID for verification only Input password for verification only Only Press and then input duress password Password Second way press to confirm at last Punch card for verification Only Card Press input duress password and then Second way press to confirm punch card at last Press finger for verification Fingerprint or Input password for verification Password Press and then input duress password Third way press to confirm at last Punch card for verification Card or Press finger for verification Fingerprint Press input duress password and then press to confirm punch card at last hird way Punch card for verification Card or Input password for verification hird way T Password T Press and then input duress password press to confirm at last User ID and Input user ID and press finger for verification and there is Fingerprint no order Password and Input password and press finger for verification and there Fingerprint is no order Card and Punch card and press finger for verification and there is Fingerprint no order Punch card and input password for First way ee ter Card and verification and there is no order Password Press input duress password and then Second way press 4 to confirm punch card at last Card Punch card press finger and input password for Fingerprint oe verification and there is no orde
4. ick the Reset button hole with a sharp tool diameter is less than 2mm Reset Switch elt DI set io Bottom View 2 Dip Switch Setting It is adopted binary coding and little endian Number 1 4 switches are used to set the 485 address number device number The address numbers setting by place these 4 switches are shown as the table below ates Sunen sting Adress Sich ating BS Note 1 Number 5 switch is idle 2 The sixth switch is used to set the terminal resistance in RS485 communication When the sixth dip switch is set in ON state it means a terminal resistance of 120Q is between 485 and 485 in parallel 3 Wiring Terminals Terminal Resistance Bell i Power Supply Back View Wiring Terminals BS Note When connecting With Standalone Access Control please set the dial code address 1 to ON position 4 Verify Mode After the reader is powered on independently the reader can not identify the fingerprint password or card In other words the reader can not receive data or send data without connectiong with Control Panel or Standalone Access Control Operation Tips 4 The indicator turns green and the buzzer Verify successfully makes a long beep 1 The indicator turns red and the buzzer makes Verify failed two short beeps i The indicator turns green once every two Verify state seconds and the buzzer makes no beep I The indicator
5. r and Password Input user ID and then input password User ID First way CON press finger for verification at last Password and Press finger and then input password Fingerprint Second way SANA press user ID for verification at last Fi int First Press finger and punch card for ingerprint irst wa Dr ER a verification and there is no order Card or User Press finger and input user ID for ID Second way ae verification and there is no order SE No matter which verify mode is setted emergency password is effective on Control Panel The emergency password is alse effective on the reader when connecting with Standalone Access Control which supports emergency password 2 When connecting with Control Panel or Standalone Access Control the firmware on device decides verify modes 3 For how to set verify modes please read the software user manual e e 5 List of Parameters Power Supply DC 12V 3A Fingerprint Collecter IR fingerprint reader Connect GND cable firstly and power cable is connected after all the other wiring It is recommend to use the DC 3A 12V power supply Keep the exposed part of wire is less than 5mm to avoid unexpected connection and result in machinery damage Recommend operating temperature range 0 C 45 C It is recommend that the distance of 485 communication is less than 200 meters when power supply independently It is recommend that the distance between powe
6. r supply and decvice is less than 100 meters and connecting less than 5 readers when sharing power with Control Panel

Download Pdf Manuals

image

Related Search

Related Contents

EasyFit. - Icon Heath & Fitness  AUFBAU-UND BEDIENUNGSANLEITUNG  Modulo IV  Samsung CTI613GIN Käyttöopas  USER MANUAL - CCL Computers  2012.10.18 - Repere Liquide  Deux_Cours_en_Eveil_V2011-07-31  4月15日号(No.2) [2001KB pdfファイル]  

Copyright © All rights reserved.
Failed to retrieve file