1. 0 in 0 163 flashes If setting for currency symbol is not necessarily required press down key to enter the module of income coefficient setting Notes suppose that is selected as the currency symbol the display of currency symbol will change to the currency symbol selected at this step the default currency symbol of the system is 2 3 2 Income coefficient setting After the currency symbol is selected press OK for a short while to enter the module of income coefficient setting as shown in Figure 10 At the time when the 0 of 0 163 flashes press Up or Down to adjust its value ranging from 0 to 9 and press OK to confirm after adjustment then the 1 of 0 163 will flash press Up or Down to adjust its value ranging from 0 to 9 and press OK to confirm after adjustment then the 6 of 0 163 will flash press Up or Down to adjust its value ranging from O to 9 and press OK to confirm after adjustment then the 3 of 0 163 will flash press Up or Down to adjust its value ranging from 0 to 9 and press OK to confirm after adjustment At the moment 3 stops flashing and the interface is restored to the status as shown in Figure 9 then Kg CO2 starts to flash ee pe in aak aaa a ee es rer 03 8 veo it EE Lo T a Figure 11 Figure 12 Figure 13 2 3 3 CO2 coefficient setting Press OK for a
2. energy generation revenue and CO2 emissions on the day The three data are displayed once every 5s in cycle The sequence of display in cycle is generated energy generation revenue and then CO2 emissions as shown in Figure 17 to 19 There are two modes in the third line one showing the generated energy generation revenue and CO2 emissions in the month and the other showing the total generated energy total generation revenue and total CO2 emissions Two modes are divided into six interfaces and each interface is displayed after every 5s in cycle as shown in Figure 17 to 22 The means of display in cycle is Today Total Today Month Press OK for a short while in the default interface you will enter the enquiry of daily monthly and total data When entering the enquiry interface the historical daily and total data will be displayed as shown in Figure 17 Then press Down for a short while for enquiry of generated energy generation revenue and CO2 emissions from Today to Total in sequence as shown in Figure 17 to 19 and for enquiry of generated energy generation revenue and CO2 emissions from Today to Month in sequence as shown in Figure 20 to 22 Or press Up for a short whole and you will see the enquiry results in the opposite direction The default interface will appear by pressing OK for a short while in any interface of enquiry or when there is no operation of enquiry at all in 30s The fourth line indicates
3. or Down to adjust its value ranging from 1 to 12 and press OK to confirm after adjustment then the Day 01 OWOVeoll will flash press Up or Down to adjust its value ranging from 1 to 31 and press OK to confirm after adjustment then the date will stop flash Now the interface is restored to the status as shown in Figure 9 and the time starts to flash If there is no need to set data press Down to enter the time setting module 2 3 5 Time setting When the time symbol flashes press OK for a short while to enter the time setting module as shown in Figure 13 then the Hour 00 of OO 00 will flash press Up or Down to adjust its value ranging from 00 to 23 and press OK to confirm after adjustment the Minute 00 of DO DO will flash press Up or Down to adjust its value ranging from 00 to 59 and press OK to confirm after adjustment then the time stops flashing Now the interface is restored to the status as shown in Figure 9 and Temp flashes If there is no need to set time press Down to enter the temperature unit setting module Note When entering time setting the block indicates the current system time po pen ee feat pF ep ee bafi ley Ty T 4 Figure 14 Figure 15 Figure 16 2 3 6 Temperature unit setting When Temp flashes press OK for a short while to enter the temperature unit
4. short while when Kg CO2 flashes then you will enter the setting of CO2 emission factor as shown in Figure 11 The default value of system is 0 997 At the time when the first figure 0 flashes press Up or Down to adjust its value ranging from O to 9 and press OK to confirm after adjustment then the first 9 will flash press Up or Down to adjust its value ranging from O to 9 and press OK to confirm after adjustment then the second 9 will flash press Up or Down to adjust its value ranging from O to 9 and press OK to confirm after adjustment then the figure 7 will flash press Up or Down to adjust its value ranging from 0 to 9 and press OK to confirm after adjustment Now the interface is restored to the status as shown in Figure 9 and the date O VQ 1 20 l flashes 2 3 4 Date setting When the date flashes press OK for a short while to enter the module of date g 1 0 1 20 setting as shown in Figure 12 then the third figure 1 of the Year 2011 OVOVEGI will flash press Up or Down to adjust its value ranging from O to 9 and press OK to confirm after adjustment then the fourth figure 1 of the Year 2011 D VQ VG will flash press Up or Down to adjust its value ranging from O to 9 and press OK to confirm after adjustment then the Month 01 OVO 120 Twill flash press Up
5. time and temperature 2 Press Up or Down for a short while in the default interface Figure 8 then you will enter the enquiry of phase voltage and two circuit PV voltage for three phase AC of each channel as shown in Figure 23 showing the enquiry result of CH 01 channel the enquiry for other channels are similar to it After entering such enquiry press OK for a short while and then you will enquiry in sequence and in cycle Rvolt PV1 Svolt PV2 and Tvolt PV1 as shown in Figure 23 to 25 If there is no pressing on any enquiry interface within 30s the interface will return to its default status in 30s lt a odane Fil B 8 3 28 power n Ha Ha w 0o00 PV1 Fil avevo Ti omron Power ij n B Power n n fj w a L a Tvolt 0 0 0 0 Svolt n 000 0 000 0 0 0 07 choil S5 emoi 25 ceoil 257 Figure 23 Figure 24 Figure 25 2 6 Default interface display LCD will automatically refresh its display in the default interface 1 The first line displays in default the total real time power of all photovoltaic inverters 2 The second line displays the actual generated energy generation revenue and CO2 emissions by all photovoltaic inverters on the day and the three data are displayed once every 5s and in cycle 3 There are two modes in the third line The first is to show the actual accumulated generated energy generation revenue and CO2 emi
6. The generated energy generation revenue and CO2 emissions on the day are stored and will not be reset until 0 00 of the next day or execution of reset The generated energy generation revenue and CO2 emissions in the month are also stored and will not be reset until the beginning of the next month or execution of reset The total generated energy total generation revenue and total CO2 emissions are always stored and will not be reset until data resetting is performed il ovoveos Power E E FF wi re O O Oon pe 0 00 Dun odoo 257 Figure 17 o aar Fail B 8 1 28 E 0 000 Temp BEOB ea Figure 20 ween il B 8 3 28 iPower UULU w n E E wi Boog OOO ogon 35 Figure 18 ee eee il 01 0 Vveo iPower LJ UU w E J n w Anon Month OO00 odon 35 Figure 21 2 5 Default interface switching enquiry 1 See Figure 8 for default interface oo ees il B 1 8 3 28 eae T n ij wi 0 00077 row OO GOOT odon 25 Figure 19 Fri B 8 veo Power Ha ij wi Today FE n n n Month nooo Temp ocon 25 Figure 22 The first line indicates in default the total instantaneous power of each inverter connected When the power is not less than 1000W the unit kW W will be shifted to kW automatically The second line indicates the generated
7. appear and LCD will show the data of the current channel The following figures show relelevant display under relevant codes by switching 6 sensor channels in the default interface In the default interface the total data for Channel 1 to 6 are displayed as shown in Figure 27 The LCD display is shown as Figure 28 to 30 after entering all channels The figures show the data of CH 01 channel the data of other channels are much similar and the only difference is that clock areas show relevant channel numbers The explanations on LCD display are as follows 1 The first line shows the real time power of photovoltaic inverters for each channel 2 The second line shows phase voltage for three phase AC of each channel 3 The third line shows two circuit PV voltage for each channel 4 The fourth line shows time and real time temperature under the current environment Notes When choosing CH 01 to CH 06 press OK for a short while for the enquiry of Rvolt PV1 Svolt PV2 and Tvolt PV1 for relevant channel and the clock area will display relevant channel number Fil 04 8 1 28 tt a iii ij Ha i w ian aaa il ovoveor Power if n fe rewon O Booo aooo or ovoveor Power E Ha w loar n000 pe 7 00 0 Svolt 0 0 0 0 nooo PV1 D0007 ogo 257 CHO I 25 ceo Il 25 Figure 27 Figure 28 Figure 29 5 lt il G 8 Vv
8. e a while 3 seconds later the red LED flashes quickly twice and then release the key to enter basic setting LCD displays as shown in Figure 9 at this time the currency symbol will flash switch over among various function modules through down key Setting should follow the order of currency symbol system default as income coefficient system default as 0 163 emission coefficient system default as 0 997 date time temperature unit system default as C buzzer switch system default as bOFF status press up key to convert the order Restore to the default interface as shown in Figure 6 if there is no key operation within 1 minute in the interface of basic settings or restore as all options are set Tkg coz HOFF oooo 25 gt O Figure 9 Figure 10 l 0 3 8 veo Note When pressing Ok after all items are set the LED light will flash twice to indicate the setting are verified valid 2 3 1 Currency symbol setting Press OK key to enter the module of currency symbol setting as shown in Figure 10 when the currency symbol flashes Now symbol flashes Press down key symbol flashes press the down key again flashes Then press up key to convert the order When a currency symbol flashes press OK key to select the currency symbol Then the currency symbol stops flashing meanwhile you enter the module of income coefficient setting and
9. eo lPower n J n B Tvolt oog PV1 CHO a Figure 30 Contact 3 If you have some requirements or problems concerning ShineVision please contact us and provide related information
10. he RS232 port of Growatt inverter is compliant with the specification 2 as i figure5 a please plug the transmitter to the inverter directly via the RS232 and lock screw figure5 b show Detailed information refers to the next paragraph i C Figure 5 Connect the transmitter to inverter After the power is energized the default interface displays press down and up keys shortly and select the channel No optional from channel No 1 to 6 and press the down key for about 3 seconds until the red LED light quickly flash twice then release it After a quite while simultaneously push aside the black button and then press the red button on transmitter for a while until the red LED light quickly flash twice you will automatically enter the code matching of the channel as shown in Figure 6 Antenna symbol flashes once per second LCD displays as shown in Figure 7 After releasing the red button on the transmitter LCD will display as shown in Figure 8 Upon the successful matching of codes LCD will displays as shown in Figure 8 in case of code matching fails in 1 minute LCD will display the default interface as Figure 4 Notes Antenna symbol is not displayed if codes are not matched vice versa display once the codes are successfully matched rr M fa e D a TT cy ee ee ee e e ocoo BE Figure 6 Figure 7 Figure 8 2 3 Basic Setting In the default interface press OK key for quit
11. powering tomorrow rowall ShineVision Operation Manual gt GROWATT NEW ENERGY CO LTD No 28 Guanghui Road Longteng Community Shiyan Baoan District Shenzhen P R China T 86 755 2747 1900 F 86 755 2747 2131 E service ginverter com W www ginverter com GR UM 007 02 Table of Contents Product Overview 2 Basic Operations and Display of Functions 2 1 Check of software version and clear 2 2 Code matching operation 2 3 Basic Setting 2 3 1 Currency symbol setting 2 3 2 Income coefficient setting 2 3 3 CO2 coefficient setting 2 3 4 Date setting 2 3 5 Time setting 2 3 6 Temperature unit setting 2 3 7 Buzzer setting 2 4 Data storage 2 5 Default interface switching enquiry 2 6 Default interface display 2 7 Reading of Data of Emitter No 1 to 6 3 Contact Product Overview 1 ShineVision which consists of a power monitor and a number of transmitters can achieve 1 to 6 monitoring modes The transmitters transmit the power data collected from a photovoltaic inverter to the monitor and display the data onto the monitor screen as along as data of generated energy the gross generated energy and the generation income obtained from the above mentioned data through some simple calculations We can also see 3 phase AC voltage two way PV voltage indoor temperature date and time as well as CO2 emissions Overview v art YS Cu ow l Growan A OK es yv Figure 1 Power Monitor and T
12. ransmitter Notes Power up the monitor via the power adapter which is delivered in the package box But for convenience sometimes it s available to use batteries 2 Basic Operations and Display of Functions 2 1 Check of software version and clear Insert power supply or batteries after pressing up and down keys concurrently LCD will display 3 seconds in full screen as shown in Figure 2 The red LED light flashes quickly twice 3 seconds later 0 5 second per time then release the up and down keys LED light will be on for a long time LCD will show the version No of the software as shown in Figure 3 LED light will turn off 3 seconds later and LCD resets to the default interface as shown in Figure 4 The relevant information has been cleared Note Factory default date 01 01 2011 dd mm yy default time 00 00 Tal aavaseos Q a ovov an Loo ipower B B B Power eL kw n Rvolt Svolt Tvolt BBB Be Today MWh e e e KWh Month PV1 PV2 i BBB e e e KWh Temp fe Power oooo 25 Figure 2 Figure 3 Figure 4 2 2 Code matching operation Before code matching operation Please check the RS232 port type If the RS232 port KK of Growatt Inverter is compliant with the specification 1 as figure5 a please push or A ae the pin1 button up then plug the transmitter to the inverter via the RS232 and lock screw as figure5 b show If t
13. setting module as shown in Figure 14 then C default system temperature unit will flash Press Down F will flash press Up C will flash When the temperature unit flashes press OK for a short while and confirm the selection of the current temperature symbol And now the symbol stops flashing and the interface is restored to the status as shown in Figure 9 then bOFF flashes If there is no need to set temperature unit press Down to enter the buzzer setting module Note When entering temperature setting the place showing temperature indicates the current ambient temperature in the current unit 2 3 7 Buzzer setting When bOFF flashes press OK for a short while to enter the buzzer setting module as shown in Figure 15 Then BUFF will flash Press Up or Down fora short while and you can make a shift between BOFF and bON After the status of the buzzer is set well press OK to confirm and then LCD will return to the default interface If there is no need to set the buzzer press Down and then LCD will return to the default interface Notes When choosing Of and pressing OK the buzzer will be opened and the sign of ring at the upper right corner of LCD will display as shown in Figure 16 While choosing bOFF and pressing OK the buzzer will be closed and the sign of ring will not display The system default status of the buzzer is closed 2 4 Data storage
14. ssions by all photovoltaic inverters in the month as shown in Figure 20 to 22 the second is to show the actual accumulated electric energy generation revenue and CO2 emissions by all photovoltaic inverters The two modes are divided into six interfaces and each interface is displayed once every 5s and in cycle as shown in Figure 17 to 22 The sequence of cycle is from Total to Month 4 The fourth line shows the time and temperature Notes When the monitor receives error information of photovoltaic inverters the first line will display Error and its relevant wrong code supposing 000 Meanwhile the buzzer will alarm twice every five minutes if the buzzer is set opened as shown in Figure 26 and the LEC lamp will flash once every second The display results of the second and third lines must be corresponding to each other It means when the second line displays generated energy on the day the third line must display the total generated energy or generated energy of the month at the same time The data must be displayed correspondingly and in cycle and the means of display in cycle is Today Total and Today Month as shown in Figure 17 to 22 Fil B 3 8 1 28 3 0900 r 2 00 Dan Soana Figure 26 12 2 7 Reading of Data of Emitter No 1 to 6 Press Up or Down for a short while in the default interface then CH 01 or CH 06 will be displayed in the clock area the clock symbol will dis
Download Pdf Manuals
Related Search
Related Contents
平成 年度 18 実施設計書 小県郡長 和町 和田∼岡谷 American Dryer Corp. AD-360X2 Clothes Dryer User Manual Coussin pour cryothérapie à usage unique Fiche Technique Mikrotik S-RJ01 network switch module Operating Instructions - B Information - VHS Offenburg Fujitsu FI-6140Z Photo Scanner User Manual Data Sheet Final - ADSP-BF50x Blackfin PK2025 Copyright © All rights reserved.