Home

User`s Guide Digital Sound Level Meter

image

Contents

1. when applicable 2 Calibrate the instrument before each use if possible Especially if the meter has not been used for a long period of time Do not store or operate the instrument in areas of high temperature or humidity Keep meter and microphone dry Avoid severe vibration Remove the battery when the meter is to be stored for long periods of time SP Oh ae oe 4 Model 407730 Version 1 4 April 2006 Specifications Display LCD with bargraph Dimensions weight 9x 2 3 x 1 7 230 x 57 x 44mm 6oz 172g Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment a six month limited warranty applies to sensors and cables If it should become necessary to return the instrument for service during or beyond the warranty period contact the Customer Service Department at 781 890 7440 ext 210 for authorization or visit our website www extech com for contact information A Return Authorization RA number must be issued before any product is returned to Extech The sender is responsible for shipping charges freight insurance and proper packaging to prevent damage in transit This warranty does not apply to defects resulting from action of the user such as misuse improper wiring operation outside of specification improper maintenance or repair or unauthorized modification Extech specifically disclaims any implied warranties or merchan
2. 004 Extech Instruments Corporation All rights reserved including the right of reproduction in whole or in part in any form 6 Model 407730 Version 1 4 April 2006
3. User s Guide EXTECH INSTRUMENTS Digital Sound Level Meter Model 407730 Introduction Congratulations on your purchase of the Extech 407730 Digital Sound Level Meter The 407730 measures and displays sound pressure levels in dB from 40 to 130dB User selectable features include Frequency Weighting A and C Response Time Fast and Slow Max Hold and Max Min recording Careful use of this meter will provide years of reliable service Meter Description o_o Microphone LCD Display ON OFF button A C weighting selection button Min Max Record button Range selector button F S response selection button 407730 Max Hold selector button FAST Calibration adjustment SPL T X T 1 1 3 Se ete ee p oN Fake Fo ee 0 1 21 s 9 AC analog output jack Sound Level Meter o_o s Windscreen Record icon Auto or Manual range 7 8 9 10 Range indicator 1 Bargraph A or C weighting 2 AUTO Low bat icon manu i i TE 5 Max level indicator E l E Hold indicator 3 Sra lm Min indicator 4 enpo Fast or Slow weighting 20 30 dB display a ee ae ee A ee 2 Model 407730 Version 1 4 April 2006 Operation 1 Power the meter by pressing the D power button The meter will begin displaying sound level readings If the LCD does not switch on check the 9V battery located in the rear battery compartment 2 Hold the meter away from the body 3 View the measur
4. cally select the best range for the noise level being measured If the measured dB level exceeds the range of the meter or the range of a selected range HI will appear in the display If the measured dB level is lower than the selected range LO will appear in the display 1 Press the RNG button to manually select the range MANU will be indicated on the display The four ranges are 40 70 60 90 80 110 and 100 130 Press the RNG button to step through the ranges 2 Press and Hold the RNG button for 2 seconds to exit the manual range mode MAX HOLD In this mode the meter only updates the LCD when a higher reading than the one presently on the display is detected 1 Press the MAX HOLD button to enter the Max Hold mode The MAX HOLD icon will appear in the display 2 Press the MAX HOLD button again to exit this mode 3 Model 407730 Version 1 4 April 2006 MAX MIN Recording In this mode the meter records the Maximum and Minimum readings and stores them into memory 1 Press the REC button to enter the RECORD mode The REC icon will appear in the display 2 Press the REC button again to display the minimum value recorded since the mode was entered The MIN icon will appear in the display The meter is not recording during this time 3 Press the REC button again to display the maximum value recorded since the mode was entered The MAX icon will appear in the display The meter is not record
5. ement on the meter s display If the meter is in the autoranging mode the display may briefly indicate HI or LO if the noise level is above or below the currently selected range The meter will change the range as needed to display the dB level A and C Frequency Weighting Use the A C button to select A or C frequency weighting With A weighting selected the frequency response of the meter is similar to the response of the human ear A weighting is commonly used for environmental or hearing conservation programs such as OSHA regulatory testing and noise ordinance law enforcement C weighting is a much flatter response and is suitable for the sound level analysis of machines engines etc A or C icons will appear in the display Most noise measurements are performed using A Weighting and SLOW Response FAST and SLOW Response Time Use the F S button to select FAST 125 ms or SLOW 1 second response time Select FAST to capture noise peaks and noises that occur very quickly Select the SLOW response to monitor a sound source that has a consistent noise level or to average quickly changing levels FAST or SLOW icons will appear in the display Select Slow response for most applications Auto or Manual Ranging The meter will turn on in the auto ranging mode and AUTO will be indicated on the display In this mode the meter will automati
6. ing during this time 4 Press the REC button again to display the present dB level and continue recording 5 Press and hold the REC button until the REC icon clears to exit the mode Auto Power Off The meter will automatically shut off after 20 minutes of operation To disable this feature 1 With the meter OFF Press the and MAX HOLD buttons simultaneously 2 will appear in the display 3 Release the 1 button and then release the MAX HOLD button 4 The meter will remain on until the power button is pressed Calibration To calibrate the meter an external calibrator such as the Extech 407744 or the Extech 407766 is required in addition to a small screw driver 1 Turn the meter ON 2 Select the 80 to 110dB range 3 Select A weighting and SLOW response 4 Place the microphone into the calibrator Set the calibrator to output a 1kHz sine wave 94dB 5 Adjust the calibration potentiometer for a display as close as possible to the calibrator s output Battery Replacement When the q__ j low battery icon appear replace the battery by removing the screw securing the rear battery compartment and replacing the 4 AAA batteries Tripod Mount A camera tripod mount is located on the rear of the meter for increased stability and elimination of body reflections Measurement Considerations 1 Wind blowing across the microphone increases the noise measurement Use the supplied windscreen to cover the microphone
7. tability or fitness for a specific purpose and will not be liable for any direct indirect incidental or consequential damages Extech s total liability is limited to repair or replacement of the product The warranty set forth above is inclusive and no other warranty whether written or oral is expressed or implied Calibration and Repair Services Extech offers repair and calibration services for the products we sell Extech also provides NIST certification for most products Call the Customer Service Department for information on calibration services available for this product Extech recommends that annual calibrations be performed to verify meter performance and accuracy 5 Model 407730 Version 1 4 April 2006 Typical A Weighted Sound Levels dBA 40 SOHP Siren 100 Jet takeoff 200 Riveting machine Chain saw Subway 20 Pneumatic drill 50 Boiler room Freight train 100 Vacuum cleaner 10 Speech 1 Large store Large Office minalhorier Residence Night residential area Whisper 5 0 Sound studio Threshold of hearing Support line 781 890 7440 Technical support Extension 200 E mail support extech com Repair amp Returns Extension 210 E mail repair extech com Product specifications subject to change without notice For the latest version of this User s Guide Software updates and other up to the minute product information visit our website www extech com Copyright 2