1. a Sa z ax gt nS b Qs 8 aa O W E ul ey e R a3 2 Q of L 7 amp o g a 2 o 8 Z ww o9 LASMDVd HOS ALVIdINAL abpa 100p uo auay 44 A b E Z WWOL LISXDY8 HOS I l l N 8 L Z wUpS Limited Warranty Statements 1 Warranty Tong Lung Metal Industry Co Ltd hereafter TL warrants the Product to be free from defects in material and workmanship for a period of 12 months from the original date of purchase If you discover a defect in the Product covered by this warranty we will repair or replace the item at our option using new or refurbished components 2 Exclusions This warranty covers defects in manufacturing discovered while using the Products as recommended by TL rather than occurred by the act of God and damages caused by misuse abuse and unauthorized modification 3 Limited of Liability TL will not be held liable for incidental or consequential losses or damages to any act of God 4 Reminder Service requirement shall subject to the presentation of this warrant card and defective parts to the manufacture TL The warranty card will not be reissued if lost Product KEYPAD ELECTRONIC DEADBOLT LOCK Purchase Date MaxGrade a KEYPAD ELECTRONIC DEADBOLT LOCK USER MANUAL aT 2 Attention Please do not use the electronic screwdriver for installation KEYPAD ELECTRONIC D
2. lock without programming function 6 4 User Code is 4 10 digits in length 6 5 User Code can be deleted or changed anytime if needed 7 Delete Individual User Code 7 1 User Codes can be deleted individually You can reset the same number as code even it s deleted before 7 2 You should enter Programming code to delete individual User code 8 Delete All User Codes At Once 8 1 All the User Codes can be deleted at once You can still reset the same numbers as codes even they re deleted before 8 2 Auto locking and Keypad locking function will be invalid after deleting all User Codes and the lock can only be operated by key All the electrical functions will be restored when recreate new User Codes 8 3 You need to enter Programming Code to delete all User Codes 9 Temporarily Disable All User Codes 9 1 Auto locking and Keypad locking function will be invalid when User Codes are temporarily disabled The lock can only be operated by key during the time 9 2 Repeat the programming steps again to restore the User Codes 10 Create a Disposable User Code 0 1 Disposable User Code will be no longer valid once being used 0 2 You can reset same number as Disposal User Code 0 3 You need to enter Programming Code to create a Disposable User Code 11 Restore Preset Factory Code 1 1 You can restore Preset Factory Code by pressing R button on the interior receiver module when you forget Programming Code or you want to cancel all prev
3. 54mm through the door face for the lockset then a hole of 1 25 4mm for latch c Insert the strike and tighten it with screws Note please use tapping screws for metal door M i 5 Install Keypad Assembly a Ensure the latch bolt must be retracted b Please refer to the diagram below for Cylinder Installation Place deadbolt against keypad with tailpiece in horizontal position inserted through hub of the latch c Pass the IC wire under the latch to the interior side of the door Cylinder 6 Install Inside Mounting Plate Pass the IC wire through the wire hole of the mounting plate Fix the mounting plate with screws If outside lock assembly is lopsided please Screws loosen the screws to adjust it s position and ea tighten the screws again Mounting Plate 7 Identify Door Handing Face the door from outside the door is left handed if the hinge is on the left hand side of the door whereas the door is right handed if the hinge is on the right hand side of the door Interior Door t ON Ze Hinge Exterior Left Handed Right Handed SA 8 Adjusting Turn Piece Turn the turn piece to left for 45 degrees when it s right handed door Turn the turn piece to right for 45 degrees when it s left handed door For Right Handed door For Left Handed door 9 Install receiver module a a Remove the battery
4. D Indicator 3 1 LED flashes green once when successful operation 3 2 LED flashes green twice when successful programming 3 3 LED flashes red 3 times when there is an operation error 3 4 LED flashes red 5 times when codes input error the operation will stop for system protection Refer to 17 3 5 LED flashes orange 3 times when system has been restored to default setting 3 6 LED flashes orange slowly while in programming mode 4 Audio Indicator 4 1 1 beep sound indicates a successful operation 4 2 2 long beeps indicate a successful programming 4 3 3 beeps indicate an operation error 4 4 3 long beeps indicate that system has been restored to default setting 4 5 5 beeps when codes input error the operation will stop for system protection Refer to 17 4 6 10 rapid beeps indicate the power of battery is low 5 Programming Code 5 1 The preset Programming Code is 0000 Please delete it and create your personal code when first time operation 5 2 Only one set of Programming Code for function setting 5 3 Programming Code is only for function setting you can t unlock the door by pressing Programming Code 5 4 Programming code is 4 10 digits in length 5 5 Programming code can be changed anytime if needed 6 User Code 6 1 The preset User Code is 1234 Please delete it and create your personal code when first time operation 6 2 Up to 6 sets of User codes can be saved 6 3 User Code is only for activating the
5. EADBOLT 3 Install Latch Insert the latch and iti lleled t INSTALLATION INSTRUCTIONS a Insert the latch and ensure itis paralleled to a Mark the outline of the faceplate then take The BACKSET is the distance between the center of out the latch cross bore and edge bore of the door Adjustable latch fits both BACKSET of 2 3 8 60mm and 2 3 4 70mm Please follow the steps shown below for BACKSET adjustment O b Chisel 1 8 3mm deep along the outline to allow the faceplate to be aligned with the door edge Latch Backset Adjustment Rotate the latch case as diagram on the right for backset 2 3 4 70mm or reverse direction for 2 3 8 60mm c Insert the latch and tighten it with screws Note please use tapping screws for metal door 1 Mark The Door With Template Select the height and backset as desired on the door face use the TEMPLATE as an indication to mark the center of the circle on the door face and the center of the door edge 2 Drill Holes a To identify the center of strike close the door on the basis of the faceplate mark horizontal center line of strike Ensure the center of faceplate and the center of strike are aligned Use the mark as a guide outlines the strike b Chisel 5 64 2mm deep along the strike outline to allow the strike to be aligned with the doorframe Using the marks as a guide to drill a hole 2 1 8
6. cover push it up and pull it out b Connect the IC wire and ensure the tailpiece is engaged with turn piece then attach receiver module to the door with screws It s optional to use wood screws Wood screws only for wood door c Insert 4 AA 1 5V alkaline batteries and put the battery cover back to the receiver module Wood Screws gt Screws Programming Button It s also lock button Number Buttons nput the pass codes each pass code is 4 10 digits in length Cylinder Retract Extend the latch bolt by key from exterior Washer Prevent water permeating into lockset Battery Lid Slide the lid to change the batteries or restore default setting Battery Holder Four AA 1 5V Alkaline batteries R Button Reset Restore default setting Turn Piece Retract Extend the latch bolt from interior Programming Button is for entering codes clearing errors and setting function E Specification Function 1 Battery Four AA 1 5V Alkaline batteries 2 Low Battery 2 1 The batteries should be changed immediately once you see the LED flashes in red and hear constant beep sounds for about 10 seconds when press programming button 2 2 All settings are retained in the memory and will not be affected even if the battery is completely dead 2 3 The lock still can be operated by key even there is a power outage 3 LE
7. ding indentifying process the latch does not work Feeling that the motor runs powerlessly the latch bolt is stuck and the turn piece inside cannot be rotated Causes Low battery Solutions Please replace with new batteries Situation 5 The functioning has been normal but suddenly the latch bolt locks up and the turn piece inside cannot be rotated not even with the key Causes The detection of latch bolt position is abnormal Solutions Please take out one battery first then press any button on the front panel for electric discharge and put the battery back next The latch bolt will automatically re detect its position subsequently Attentions When the latch gets stuck frequently please check if the opening of the strike aims at the central position of the latch bolt if the latch bolt can stretch out freely or if the hinges are deformed or tilted Situation 6 The door can be locked normally but three short beeps are heard and the door would not unlock when the user code is entered and the programming button is pressed Causes The functioning of the micro switch is abnormal Solutions Please unlock the door with the keys first and then contact the distributor for inspection and maintenance Situation 7 While the door is closed you hear the latch bolt coming out when you press the programming button to lock the door however three short beeps are emitted Conversely while the door is ope
8. he period you want 15 4 Please repeat the same programming steps to cancel Auto Locking function when needed 15 5 The system will alarm twice if the latch bolt gets stuck or not extended retracted completely You need to enter User Code to unlock the door for remaining the bolt retracted The auto locking function will be restored then 16 Toggle Mute On Off 16 1 You will hear beep sounds when pressing keypad programming or operating errors It can be turned off if needed 16 2 LED Illumination is still functioning when it s in mute For there will be no any warning alarm we suggest not to mute the beeper if it s not necessary 16 3 Motor operating sound cannot be muted 17 Code Protection Function The operation will stop if entering unauthorized codes over 5 times The System will re operate again after 45 sec 18 Illumination The LED Keypad will light up when pressing any button for ease of operating in the dark E Pass Code amp Function Set up 1 It should be remained unlock while programming 2 Please run the door handing identifying process Refer to programming table before function set up when first time installation or default setting restore 3 Please change default Programming Code 0000 and User Code 1234 before function set up when first time operation 4 LED flashes orange slowly while programming LED flashes green twice with 2 long beeps when correct input LED flashes red 3 times wi
9. ious setting 1 2 After restore the Programming Code would be 0000 the User Code would be 1234 again 12 Unlock the door 12 1 The door will be unlocked by key or pressing User Code on keypad from outside or by interior turn piece 12 2 To unlock the door on the keypad enter the User Code and then press the Programming Enter button 13 Lock the door The door will be locked by key or pressing Programming Button on keypad from outside or by interior turn piece 14 Incomplete Door Closing Opening 14 1 Once the latch bolt is not extended retracted completely and causing a not functional motor operation when it s locked by keypad you ll see LED flash red 3 times for twice and hear 3 beeps No alarm when it s in mute You need to enter User Code to unlock the door for remaining the bolt retracted and press Programming Button to lock the door again 14 2 If the latch bolt gets stuck or can t extend retract completely all the time please check if the strike aligns with the latch bolt perfectly and adjust the strike to proper position After long use of the door hinge the latch bolt might get stuck easily because the door is deformed or lopsided 15 To Activate Deactivate Auto Locking Function 15 1 The door will automatically lock itself within 10 99 seconds when this function is programmed 15 2 This function is not preset at the beginning it can be set if needed 15 3 The preset delay time is 30 seconds you can adjust t
10. n no beeps are emitted when locking the latch bolt Causes 1 The depth of the latch bolt hole is insufficient 2 The latch bolt is not aimed at the opening of the strike Solutions 1 Please dig the latch bolt hole for the strike deeper min depth of 2 5 cm 2 Please adjust the strike to the appropriate position
11. nce Enter PC mp MaxGrade G gt Remark Auto locking and Keypad locking function will be invalid when User Codes are deleted The lock can only be operated by key during the time Change Programming Code Enter PC mp MaxGrade 4 MaxGrade Enter New PC MaxGrade Toggle Autolock On Off Enter PC mp Maxtirade mp Remark The preset delay time is 30 seconds you can change the time by following instruction Repeat the steps to cancel the Auto locking function 11 Programming Code PC USER Code UC Set Autolock Time Delay Enter Second Enter PC Maxtirade mp 6 p Maxfirade mp see S ap Maxtirade Remark 10 99 seconds delay time available Toggle Mute On Off Enter PC p Maxffrade p Q Remark Repeat same steps to turn beeper On Off LED illumination is still functioning when it s in mute But there will be no any warning alarm Enable Disable All User Code COMOD Remark Auto locking and Keypad locking function will be invalid when User Codes are disabled The lock can only be operated by key during the time Repeat the steps to enable the User Codes again Create a disposable User Code Enter new Enter PC m MaxGrade 9 disposable UC Remark Disposable code will be no longer valid once being used Restore all preset lock settings Press R Remark Press R button for over 5
12. seconds the programming will complete after you hear 3 long beeps After restore you need to run the door handing identifying process before other function setting 11 E Simple Troubleshooting Situation 1 After the installation of the lockset and batteries the door cannot be locked and three short beeps are emitted when you press the Programming button Causes The door handing indentifying process is not yet complete Solutions Please execute the door handing indentifying process as soon as the installation of the lockset is completed Situation 2 After the installation of the lockset and batteries no responses when you press any button no sounds are emitted and the back light does not work Causes It could be a problem caused by the batteries or the improper connection of the cable Solutions Check to see if the battery polarities have been reversed or if the battery is dead If so please re install or change the battery If not please check if the cable is appropriately connected Situation 3 Fail in the first execution of the door handing indentifying process the red light flashes three times and three short beeps are emitted Causes Wrong door handing or change of the door handing in the memory Solutions Press the R button to restore the system to factory default setting and re execute door handing indentifying process Situation 4 Although succeeded in the first execution of the door han
13. th 3 beeps when incorrect input You need to wait for 6 seconds or press programming button when incorrect input then re program the system again 5 Every programming step should be done in 6 seconds 6 You can lock unlock this product by either key or pass code Please refer to the following programming table for function set up E Remark 1 We recommend to use alkaline battery in order to stabilize the power supply 2 Do not mix alkaline battery with regular zinc carbon ones or mixed brands 3 Do not use any chemical liquid or lubricating oil with additives to clean the lock body it will damage the surface or even mainboard 4 If there is any problem of the product please contact your local retailer and send back the product to us for repair or replacement Programming Code PC USER Code UC E Function Programming Detect Left Right Hand Door Installation aa gt Ge ea Remark Please run the door handing identifying process before function set up when first time installation or default setting restore It should be remained unlock while programming Add New User Code Enter PC gt MaxGrade mp MaxGrade Enter New UC MaxGrade Remark Up to 6 sets of User Code can be saved User Code should be 4 10 digits in length Delete An Existing User Code Enter the UC Enter PC m MaxGrade 2 gt gt youwantto delete Delete All User Code At o

Download Pdf Manuals

image

Related Search

Related Contents

User Manual Logamax plus GB142 - USA/CA    BT-112 spanish manual.cdr  HP 5890 Series II GC Service Manual (05890  Duraflame DFH-CH-11-T Use and Care Manual  LG M1710A-BZ 17" Black LCD TV  Sharp MX-2600N Brochure  CMD - Mode d`emploi  無線 LAN ルータ(WRC-1000) 取扱説明書  Installation & User Manual Radio Remote RC-10E  