Home
Manual 5100 - Communications Specialties, Inc. Communications
Contents
1. Communications Specialties Fiberlink 5100 User s Manual Transmit 10 100 1000 Base T Ethernet over one or two single mode or multimode fibers The 5100 Series is full featured with auto sensing 10 100 1000 Mbps Ethernet port with Auto MDIX and full and half duplex support And of course the signal fidelity you have come to expect from Fiberlink Fiberlink 5100 Series 10 100 1000 Base T Etheret over one D Leal c icati or two single mode or multimode fibers CS Specialties Inc World Headquarters 55 Cabot Court Hauppauge New York 11788 USA Tel 631 273 0404 Fax 631 273 1638 info commspecial com Asia Communications Specialties Pte Ltd 100 Beach Road 22 09 Shaw Tower Singapore 189702 Tel 65 6391 8790 Fax 65 6396 0138 csiasia commspecial com commspecial com a qapom he lOmsy va ts Contents Contents WW EICOING sacecsteacntcetceecs oe oot tcaeunds Aaseueven doses meee seeeenesa eee 3 Pe ONES PE TET A E E EEEE E T E TEE T E 3 Package Contents ccaccaceceennscenciigessecivaneds baoseeuasduneassapeuess 3 Technical Specifications Model Part Number Specifications 0 ccc cece cece eee e ee eaes 4 General Specifications s ssssesesrueesususerueesrererererrsese 4 Operating Loss BUQGEIS 654 icsuu cameeaunemaiavareemieaienarennseses 5 Maximum Useable Distance cece cece eee e ene e eee eennnes 5 Ethernet Cable Requirements ccc ccc ccc cece ee
2. Maximum Useable Distance sections of this manual Copper RJ 45 Auto MDI MDI X Fiber Optic LC type TX LINK ACT SPD FD COL FX LINK ACT SPD FD COL Power 1 Fiber SM 8 dBm min 23 dBm max 2 Fiber SM 9 dBm min 21 dBm max 2 Fiber MM 9 dBm min 18 dBm max Input 100 240VAC 50 60Hz Output 12V 1A 0 to 50 Celcius 10 to 90 relative humidity non condensing 2 pounds 4 25 x 3 14 x 1 02 108mm x 80mm x 26mm Fiberlink 5100 Series User s Manual Fiberlink 5100 Series Optical Loss Budget Ethernet Cable Requirements Technical Specifications Optical Loss Budget amp Maximum Useable Distance cont 5100 B7L 5101 B7L 5102 B7L 5102 B1L 1000 Base BX10 U BX10 D LX LH LH10 SX Fiber Core 1 SM or MM 1SMorMM 2SMorMM 2 MM amp Type 802 Distance SM 10km SM 10km MM 50u 550m MM 50u 550m Specification SM 10km MM 62 5u 220m CSI Loss 15dB min 15dB min 12dB min 9dB min Budget pair pair CSI Typical 1k MM 1k MM 1k MM 1k Distance 10km SM 10km SM 10k SM Distance specifications are approximate based upon connecting a 5100 Transmitter to a 5100 Receiver and are not guaranteed CSI cannot estimate or guarantee operating loss budgets when the 5100 Series is used with other non Fiberlink devices Operating loss budget must not be exceeded Ethernet Cable The Fiberlink 5100 Series is compatible with standard Category 3 4 or 5 UTP cable A category 5 cable typically consists of f
3. ate and you are using a two fiber system reverse the fiber optic connections at one of the units The transmitting element in the Fiberlink 5100 transmitter unit contains a solid state Laser Diode located in the optical connector This device emits invisible infrared electromag netic radiation which can be harmful to human eyes The DANGER radiation from this optical connector if viewed at close IY IL WIL range with no fiber optic cable connected to the optical connector may be sufficient intensity to cause instantaneous damage to the retina of the eye Direct viewing of this radiation should be avoided at all times Page 6 Fiberlink 5100 Series User s Manual Fiberlink 5100 Series Indicator LEDs Indicator LEDs General LEDs Status PWR On TX LEDs Status Link On Blink SPD On Blink Off FD COL On Blink Off FX LEDs Status Link On Blink SPD On Blink Off FD COL On Blink Off Fiberlink 5100 Series User s Manual Definition Indicates that correct power has been applied Definition RJ 45 Ethernet is linked RJ 45 Ethernet is active Speed is at 1Gbps Speed is at 100Mbps Speed is at 10Mbps Full Duplex Collision occured Half Duplex Definition Optical fiber is linked Optical fiber is active Speed is at 1Gbps Speed is at 100Mbps Speed is at 10Mbps Full Duplex Collision occured Half Duplex Page 7 Fiberlink 5100 Series Operating Pointers Troubleshooting O
4. e eee e teen eee eeeeees 5 instalation INSTUCN ONS 2e te cscct ce Gare ntees oectketesesscesestGaaeasiays 6 ae leee g EES ciate roses ee dawecocnen E E 7 Operating POMUELS 2 20 6020 ed daceemiterecessmeatencsueceddaskeesdee ances 8 TOUDICSMOO UNG 45540540650 cheseennnageasn EEEE AEE eE 8 Maintenance and Repairs ccc cece cece e eee eeeeneeeenees 9 CCP EMNCAU ONS acc sacs NEEE EER EE EEEE EEEE as 9 UEC AEE E E E A sheen Seater este cae EE T 10 Accessories and Related Products usuesuesususesesseresesesserere 11 Page 2 Fiberlink 5100 Series User s Manual Fiberlink 5100 Series Welcome Features Package Contents Welcome Thank you for purchasing Communications Specialties Inc s Fiberlink 5100 Series The 5100 Series is used to transmit 10 100 1000 Base T Ethernet over one or two single mode or multimode fiber optic cores The Fiberlink 5100 Series automatically adapts to the high est level of performance supported by the device connected to the Ethernet port When the connected device is a switch or a workstation that supports full duplex the Fiberlink 5100 adapts to the full duplex mode and provides an effective 2000 Mbps bandwidth When the connected device is a HUB or a workstation that supports only half duplex the Fiberlink 5100 adapts to half duplex mode providing the nominal 1000 Mbps With high performance data transmission and easy installation the Fiberlink 5100 provides the ultimate ISP net
5. limited at its option to either the repair or replacement of defective units including free materials and labor In no event shall CSI be responsible for any incidental or consequential damages or loss of profits or goodwill CSI shall not be obligated to replace or repair equipment that has been damaged by fire war acts of God or similar causes or equipment that has been serviced by unauthorized personnel altered improperly installed or abused RMA numbers and repairs can be obtained from Communications Specialties Inc 55 Cabot Court Hauppauge NY 11788 USA Tel 631 273 0404 Fax 631 273 1638 or in the Asia Pacific Region Communications Specialties Pte Ltd 100 Beach Road 22 09 Shaw Tower Singapore 189702 Tel 65 6391 8790 Fax 65 6396 0138 RMA numbers can also be obtained from our web site commspecial com Please have your serial number available Page 10 Fiberlink 5100 Series User s Manual Fiberlink 5100 Series Accessories and Related Products Fiberlink 6610 Visible Light Source The Fiberlink Visible Light Source provides a visible 650 nm laser output that can be used for identifying fiber breaks and individual fibers within fiber bundles allowing for convenient on site testing of fiber networks during construction and maintenance procedures Fiberlink 6615 Optical Power Meter The Fiberlink Optical Power Meter measures the power of optical signals at 850 980 1310 and 1550 n
6. m wavelengths allowing for convenient on site testing of fiber networks during construction and maintenance procedures It can be used to measure the power of an optical signal reaching the receiving end of a fiber optic cable as generated either by a transmitter unit or by a light source such as the 6620 Fiberlink 6620 Three Wavelength Light Source The Fiberlink Three Wavelength Light Source offers a laser output at wavelengths of 1310 and 1550 nm and VCSEL output at 850 nm allowing for convenient on site testing of fiber networks during construction and maintenance procedures Fiberlink 5100 Series User s Manual Page 11 Communications Specialties Fiberlink 5100 User s Manual Fiberlink 5100 Series 10 100 1000 Base T Etheret over one or two single mode or multimode fibers Di CSI speciaitics Inc World Headquarters 55 Cabot Court Hauppauge New York 11788 USA Tel 631 273 0404 Fax 631 273 1638 info commspecial com Asia Communications Specialties Pte Ltd 100 Beach Road 22 09 Shaw Tower Singapore 189702 Tel 65 6391 8790 Fax 65 6396 0138 csiasia commspecial com commspecial com 2009 Communications Specialties Inc All Rights Reserved Fiberlink and the starburst logo are registered trademarks of Communications Specialties Inc CSI and the triangle designs are trademarks of Communications Specialties Inc P N 128107 Rev A
7. oting of fiber optic transmission systems and are recommended tools all installers should have available Finally although multimode and single mode devices may look the same they will not operate properly together Using the wrong device or fiber can easily add more attenuation than specified resulting in poor overall performance It should be noted that some of our fiber optic products support both single mode and multimode fiber in the same unit If after reviewing the above possibilities the system is still not operating please contact the Customer Service Department for further assistance If you suspect your problem is caused by the optics or the fiber optic cable and you have an optical power meter please take the appropriate measurements prior to contacting support Page 8 Fiberlink 5100 Series User s Manual Fiberlink 5100 Series Maintenance and Repairs Certifications Maintenance and Repairs The Fiberlink 5100 Series has been manufactured using the latest semiconductor devices and techniques that electronic technology has to offer They have been designed for long reliable and trouble free service and are not normally field repairable Should difficulty be encountered Communications Specialties maintains a complete service facility to render accurate timely and reliable service of all products The only maintenance that can be provided by the user is to ascertain that optical connectors are free of dus
8. our pairs of wires two of which are used for transmis sion The RJ 45 connector consists of 8 pins 4 of which are used for transmission as follows Designation Function TX Ethernet Differential Signal TX Ethernet Differential Signal Ethernet Differential Signal Unused Unused Ethernet Differential Signal Unused Unused Fiberlink 5100 Series User s Manual Page 5 Fiberlink 5100 Series Installation Instructions Installation Instructions The Fiberlink 5100 Series of fiber optic transmission systems are ready for immediate use and do not require any special tools or equipment However an Optical Power Meter such as the Fiberlink 6615 can be useful in determining optical loss budgets during your systems design and maintenance The following instructions describe the typical installation procedure 1 Connect the Universal Power Supply to the transmitter and receiver units When power is applied the PWR LED should illuminate indicating the presence of operating power 2 Connect any Category 3 4 or 5 Ethernet Cable to the Ethernet port of the transmitting 5100 Series unit The TX Link LED should illuminate 3 Connect any Category 3 4 or 5 Ethernet Cable to the Ethernet port of the receiver 5100 Series unit The TX Link LED should illuminate 4 Connect the fiber optic cable s to the transmitter and receiver units 5 The FX Link LED should illuminate If the FX Link LED fails to illumin
9. perating Pointers Remember to check attenuation of the fiber optic cable The system will only operate properly if these specifications fall within the range of the system s loss budget Troubleshooting Multimode fiber optic cable contains an optical fiber with a light carrying core that is only 0025 inches 62 5 microns in diameter Single mode fiber optic cable has an even smaller core only 00032 to 0004 inches 8 10 microns This is smaller than a human hair Therefore any minute particles of dirt or dust can easily block the fiber from accepting or radiating light To prevent this from happening always use the provided dust caps when ever optical connectors are exposed to air It is also a good idea to gently clean the tip of an optical connector with a lint free cloth moistened with alcohol whenever dust is suspected The status of the LEDs should provide the first clue as to the origin of any operational failure If these are off it usually means that the fiber is broken or has too much attenuation Next be certain that the input and output signal connections are correct If the FX Link LED fails to illuminate and you are using a two fiber system reverse the fiber optic connections at one of the units An optical power meter such as the Fiberlink 6615 a visible light source such as the Fiberlink 6610 and a Three Wavelength Light Source such as the Fiberlink 6620 can greatly assist and expedite troublesho
10. t or dirt that could interfere with light transmission and that electrical connections are secure and accurate Please see the Troubleshooting section of this manual for additional information An optical power meter such as the Fiberlink 6615 a visible light source such as the Fiberlink 6610 and a Three Wavelength Light Source such as the Fiberlink 6620 can greatly assist and expedite troubleshooting of fiber optic transmission systems and are recommended tools all installers should have available All other questions or comments should be directed to our Customer Service Department It should be noted that many problems can easily be solved by a simple telephone call If you suspect your problem is caused by the optics or the fiber optic cable and you have an optical power meter please take the appropriate measurements prior to contacting support Certifications FC Fiberlink 5100 Series User s Manual Page 9 Fiberlink 5100 Series Warranty LIMITE DIWARRANTY Communications Specialties Inc CSI warrants that for a period of three years after purchase by the Buyer this product will be free from defects in material and workmanship under normal use and service A Return Material Authorization RMA number must be obtained from CSI before any equipment is returned by the Buyer All materials must be shipped to CSI at the expense and risk of the Buyer CSI s obligation under this warranty will be
11. work solution for FTTH Fiber To The Home FTTC Fiber To The Curb or for ISPs for FTTB Fiber To The Building and can also be utilized for small office network environments Features e Auto sensing 10 100 1000 Mbps Ethernet port with Auto MDIX e IEEE 802 3 IEEE 802 3u IEEE 802 3az amp IEEE 802 3z e Full duplex and half duplex e LEDs indicate Link Activity Speed Fault Detection Collisions and Power e Single mode amp multimode versions available e One or Two fiber versions available e Compact design wall mountable Package Contents e One Fiberlink 5100 Series Unit e This User s Manual e Mounting Brackets Fiberlink 5100 Series User s Manual Page 3 Fiberlink 5100 Series Technical Specifications Model Part Number Specification Fibers UnitType Single Mode or Multimode 1310 1490 nm Single Mode or Multimode 1490 1310 nm Single Mode or Multimode 1310 nm Multimode 850 nm General Specifications Maximum Speed 1000Base Tx Fx Packet Forwarding Rate Cabling Maximum Distance Connectors LEDs Launch Power Receiver Sensitivity Power Requirements Operating Temperature Range Operating and Storage Humidity Weight Dimensions Page 4 Technical Specifications Part Number 1000 Base X 5100 B7L BX10 U 5101 B7L BX10 D 5102 B7L LX LH 5102 B1L SX Full Duplex 2000Mbps Half Duplex 1000Mbps 14880pps 10Mbps 148800pps 100Mbps 1488000pps 1000Mbps See Optical Loss Budget amp