Home

mdk-864 microprocessor diagnostic keyboard

image

Contents

1. NOT TO SCALE Figure 1 MDK 864 Keyboard 2 1 1 STATUS WORD SYSTEM ARM SIREN ON STORED STORED STORED STORED 0 NAMIE 0 DISARM 0 OFF AC ROTOR PARTIAL FULL 1 Figure 2 MDK 864 Register Readout Status Word 2 1 2 DEG ENC DATA DATA FUNCTI ON STA NT DEC INSTANT STATUS INTRUSION Figure 3 MDK 864 Register Readout Instant Status 2 1 3 DEC ENG DATA DATA SELECT PROG CLEAR FUNCTION DIPS 8 7 IMMEDIATE INSTANT AC BAT SIREN 30 SEC MASTER TMX RESPONSE RESPONSE CHECK ENABLE LEO CLR DEG FORMAT PASSWORO ON ON ON ON ON ON ON ON ENABLE ON 30 SEC ON 10 0N ON ON OFF OFF OFF OFF OFF OFF OFF OFF DISABLE OFF INFINITE OFF 8 OFF OFF OFF Figure 4 MDK 864 Register Readout Function Dips 2 1 4 SELEGT ESE DATA DATA 0 AC PROG Le FUNCTION STA T sn PROG INSTANT STATUS DIPS i 1 5 4 3 2 1 Figure 5 MDK 864 Register Readout Inatant Status Dips 2 1 5 ENC DATA SELECT PROG e m lt D CORER ERROR FLAG 6 5 4 2 1 DIGIT PASSWORD ADDRESS AREA CODE LENGTH ERR ERR ERR ERR Figure 6 HDK 864 Register Readout Decoder Error Flags 2 1 6 SELECT PROG FUNCTION DIP I EC ERR TO REMOTE 1 2 3 4 5 6 7 8 9 10 AREA CODE ADDRESS BASE 1 0 8 COMMAND SIREN 0 F GROUP COMMAND 00 BASE 0 SIREN 01 W5 3000 1 STATUS 10 WS 805 ZW EATHER 11 ws 2000 3 CONTROL Figur
2. the MDK 864 provides access to all 864 Series Remote Station Controllers memory allowing the user to change the various system programming such as a system s remote station address or to vary the pre programed timing parameters for siren voice activation durations and duty cycles Second the keyboard serves as a diagnostic monitor permitting access to the remote station s 864 Series controller s memory for examination of existing programming and status registers The MDK 864 consists of two parts the interface cable and display keyboard A slide switch is located on the rear panel of the MDK 864 keyboard next to the 25 pin D connector to activate the keyboard s programming active mode 1 1 1 Figure Figure Figure Figure Figure Figure Figure Figure J0 QIR LU IN A SECTION 2 Keyboard vese vese cos ce se cosas Readout Readout Readout Readout Readout MDK 864 MDK 864 MDK 864 Register MDK 864 Register MDK 864 Register MDK 864 Register MDK 864 Register COMM STATTM COMM STATTHM SYSTEM 10 Digit Activation Word Format 2 14 Digit Status Word Format 2 ILLUSTRATIONS 2 Status Word 2 Instant Status 2 Function Dips 2 Instant Status Dips 2 Decoder Error Flags 2 co Ja whe H GG L 5 Program Enable Slide Switch 25 Pos D Connector OFF Enable ON i EL uan TE PROGRAM IND L E CEBE El
3. WHELEN ENGINEERING COMPANY INC Route 145 Winthrop Road Chester Connecticut 06412 Phone 800 63SIREN Phone 860 526 9504 Fax 860 526 4784 Internet www whelen com Sales e mail iowsales whelen com Customer Service e mail iowserv whelen com MDK 804 MICROPROCESSOR DIAGNOSTIC KEYBOARD 864 SERIES REMOTE STATION CONTROLLERS USER MANUAL Outdoor Warning 1988 Whelen Engineering Company Inc NHELEN MDK 864 MICROPROCESSOR DIAGNOSTIC KEYBOARD FOR WHELEN 864 SERIES REMOTE STATION CONTROLLERS USER MANUAL The information contained herein is proprietary to Whelen Engineering Company Incorporated All rights reserved No part of this manual may be reproduced recorded or stored in a retrieval system or transmitted in any form or by any means whether electronic mechanical photographical or otherwise without prior written permission of Whelen Engineering Company Incorporated All Rights Reserved Copyright 1988 by Whelen Engineering Company Incorporated Printed 12 88 All materials and specifications contained within this document are subject to change without notice MDK 864 003 WHELEN ENGINEERING COMPANY INCORPORATED Route 145 Winthrop Road Chester Connecticut U S 2A 06412 WHELEN MDK 864 USER MANUAL TABLE OF CONTENTS SECTION 1 INTRODUCTION MDK 864 Dear LDE OD i tes RR ete ea daa bene 1 1 1 SECTION 2 HDR 864 SYSTEM ILLUSTRATIONS Figure 1 MDK 864 Keyboard 2 1 1 Fi
4. ations Timing durations are shown in 100ms increments To program follow step 5 11 above 4 2 1 Programming Selections Display of Program Program Selection Function Display 1 8 Siren Tone Duration Minutes Seconds 9 Siren Address Activation Word as displayed in Figure 7 Section 2 A Substitute Number Enter A c in remote station address digits according to Figure 7 Section 2 B Transmitter Turn on Delay Turn on delay time is expressed in seconds tenths of seconds PROG ENTER 1 5 Mechanical Siren Cyclic Timing Cyclic Timing is displayed in on off time durations Durations are in 100ms increments 4 2 2 4 3 DIAGNOSTIC DISPLAYS DEC DATA see Figure 7 Section 2 AREA CODE three digit number unique to each customer ADDRESS four digit number that identifies each station BASE ID identifies the base station that sent the date EQUIPMENT TAG equipment type that data is being sent to binary COMMAND GROUP 0 4 binary COMMAND 1 16 0 F hex ENC DATA see Figure 8 Section 2 DIGITS 1 10 same as DEC DATA DIGITS 11 amp 12 lt status word in hex code see Figure 2 DIGITS 13 k 14 analog voltage in hex code 0 255 STATUS WORD see Figure 2 Section 2 Two digit hex code four bit binary per digit l ON YES 0 OFF NO Dynamic AC AC power on off form last activation Pwr Up gt If AC input is on system will be powered up System Arm System armed fo
5. c of operation DEC FORMAT on off On ESC 864 will accept 10 digit format Off it will accept 8 digit format PASSWORD enabled disabled INSTANT STATUS DIPS see Figure 5 Section 2 See instant status word for bit descriptions Enabled Disabled If bit is enabled when ESC 864 sees that bit change state it will transmit the instant status word to base station DECODER ERROR FLAG see Figure 6 Section 2 Used to trouble shoot activation failures j PASS 2 ERROR PASSWORD correct incorrect DIGIT COUNT not 10 or 8 ADDRESS correct incorrect AREA CODE correct incorrect DIGIT LENGTH word transmitted to ESC 864 window time correct incorrect 4 3 3
6. d by the Remote Station s 864 Series Controller to be displayed This may be interpreted according to Figure 8 in Section 2 Pressing the STA key causes the information stored in the Remote Stations 864 Series controller s status register to be displayed This information is updated after each remote station operation The Status Register Display is indentified in Figure 2 in Section 2 Pressing the DC VOLTS key causes the remote station s battery voltage to be displayed Pressing the AC VOLTS key causes the remote station s AC supply voltage to be displayed Pressing the SEL PROG key permits the selection of a function for display or reprogramming 1 1 Key TEMP FUN DIP STA DIP CLEAR INT STA DEC ERR S N Use Function Pressing the TEMP key causes the temperature in degree s Fahrenheit inside the Remote Station s 864 Controller s housing to be displayed Note Systems may optionally be equipped with external ambient temperature sensors pressing the TEMP key for these systems will cause a display of the temperature as indicated by the external sensor Pressing the FUN DIP key causes a display of the Remote Station s Controller Function Dip Register which indicates the setting of the Function Dip switches on the remote station s 864 Series Controller See Figure 4 of Section 2 Pressing the STA DIP key causes a display of the Remote Station s Controller Instant Status Dip Register which indicates the sett
7. e 7 COMM STATtM 10 Digit Activation Word Format Don ll 0E ERR FUNCTI ON STA FROM REMOTE HU 77257 TE AREA CODE AQORESS STATUS COMMAND SI RENCOMMAND VIG A D DIGITS GROUP 0 F 00 BASE O SIREN 01 WS 3000 STATUS 10 W NL E WEATHER 3 CONTROL WORD Figure 8 COMM STATt 14 Digit Status Word Format 2 1 8 SECTION 3 MDK 864 DIAGNOSTIC KEYS 3 1 KEY DESCRIPTIONS Two 16 key keypads are located on the front panel of the MDK 864 As indicated in Figure 1 in Section 2 the left keypad offers a selection is a hex programming of Diagnostic and Programming Keys the right keypad keypad 0 9 A B 8 D which is used for selecting options and programming entry This Section details the purpose and function of the Diagnostic and Programming Keys on the MDK 864 Left Keypad as indicated in Figure 1 Key RST DEC DATA ENC Data STA DC VOLTS AC VOLTS SEL PROG in Section 2 Use Function The RST key resets the 864 Series remote station microprocessor controller This key is to be depressed following connection of the MDK 864 to the Remote Station Controller as detailed in Section 4 1 or in the event the keyboard will not clear Pressing the DEC DATA key causes the last data received by the Remote Station s 864 Series Controller to be displayed This may be interpreted according to Figure 7 in Section 2 Pressing the ENC DATA key cases the last data transmitte
8. gure 2 MDK 864 Register Readout Status Word 2 1 2 Figure 3 MDK 864 Register Readout Instant Status 2 1 3 Figure 4 MDK 864 Register Readout Function Dips 2 1 4 Figure 5 MDK 864 Register Readout Instant Status Dips 2 1 5 Figure 6 MDK 864 Register Readout Decoder Error Flags 2 1 6 Figure 7 COMM STATTM 10 Digit Activation Word Format 2 1 7 Figure 8 COMM STATTM 14 Digit Status Word Format 2 1 8 SECTION 3 mm 864 DIAGNOSTIC KEYS MDK 864 Key Descriptions lt L 0 0000 00000 raker 3 1 1 SECTION 4 MDK 864 USE WITH 864 SERIES REMOTE STATION CONTROLLERS MDK 864 Connection De connection 4 1 1 MDK 864 Programming Operations 4 2 1 MDK 864 Diagnostic USES A liki er Gi T as REE S eed deri 4 3 1 SECTION 1 1 1 MDK 864 DESCRIPTION The MDK 864 Microprocessor Diagnostic Keyboard is a service tool for use when performing service and routing maintenance on Whelen s 864 Series of Microprocessor based remote station controllers The MDK 864 consists of a keyboard with two separate keypads programming diagnostic numeric Located above the two keypads is a 20 character vacuum fluorescent display which will display programming entries and 864 series system controller programming and diagnostic information The display also indicates the MDK 864 s power on off condition and the MDK 864 programming active mode The MDK 864 serves two functions for the user First
9. ing of the Instant Status Dip switches on the remote station s 864 Series Controller See Figure 5 of Section 2 Pressing this key will set the value of the function selected MDK 864 Function Programming Keys to all zero s Pressing the INT STA key causes the information stored in the Remote Station s 864 Series controller s Instant Status register to be displayed This information is reflects the remote station s real time status The Instant Status Register Display is indentfied in Figure 5 in Section 2 Pressing the DEC ERR causes decoder error flags for data decoded by the 864 Series Remote Station Controller be displayed See Figure 6 in Section 2 for the Decoder Error Flag Register Pressing the S N key causes the most recent signal to noise ratio received by the 864 Series Remote Station Controller to be displayed The received S N value is displayed in dB 3 1 2 PROG Use Function The PROG key is used in conjunction with numeric keypad keys 0 9 A B C amp D to select the function to be programmed After pressing the PROG key the MDK 864 display will read Sel Prog Programs available are 1 Wail tone duration 2 Attach tone duration 3 Alert tone duration 4 Public Address max duration D Air Horn tone duration 6 Hi Low tone duration se Whoop tone duration 8 Five second wail tone duration 9 Siren address 0 Secur a key number A Substitute number B Transmitter turn o
10. n delay Note In order to write new program data to the 864 Series Remote Station Controller the program switch on the rear panel of the MDK 864 Keyboard must be turned to the Program Active Position The program switch is a two position slide switch The Program Active position is position nearest the 25 pin D connector on the rear panel of the MDK 864 Keyboard When the MDK 864 Keyboard is in the program Active mode and LED in the lower right hand corner of the MDK 864 Keyboard will be lighted 3 1 3 SECTION 4 MDK 864 USE WITH 864 SERIES REMOTE STATION CONTROLLERS 4 1 CONNECTION DE CONNECTION The folloving steps should be utilized vhen connecting the MDK 864 to any Nhelen 864 Series Remote Station Controller ESC 864 MS 864 and RTU 864 Installation I Turn off system AC power 2 Turn off system DC power 3 Plug into the ESC 864 4 Turn on system DC power 5 Turn on system AC power 6 Observe power on LED in upper right hand corner of MDK 864 Controller Display is on 1 Depress RST button 8 For operation refer to programming and diagnostic sections Removal 1 Turn off system AC power 2 Turn off system DC power 3 Remove cable 4 Restore system power DC amp AC System power refers to complete remote station device ie WPS 2000 Series WPS 2700 Series WPS 3000 WPS 4000 MS 864 or RTU 864 4 2 MDK 864 PROGRAMMING OPERATION The following steps detail the procedure nece
11. r instant status response Siren On System enabled disabled to make audible sound 4 3 1 STATUS WORD see Figure 2 Section 2 continued Stored AC AC power on off from previous activation Rotor rotor operation from last activation Partial one or more speakers operated form last activation Full All speakers operated form last activation INSTANT STATUS see Figure 3 Section 2 Real time data not stored 1 ON 0 OFF Tone Gen Bias tone generator on off Part one or more speakers on off Full all speakers on Intrusion cabinet door s open AC on off FUNCTION DIPS see Figure 4 Section 2 Displays the setting of the function dip switches in the ESC 864 Master TMX transmitter enabled disabled Immediate Response enabled disabled Allows the 8 864 to return status data without a request if it was activated as a individual unit Instant Response enabled disabled Allows the ESC 864 to return status data without a request if it sees a change of state on designated bits in the status register 4 3 2 FUNCTION DIPS see Figure 4 Section 2 continued AC BATT Check enabled disabled If enabled will transmit loss of AC power when battery voltage drops below 19 vdc Siren Sound enabled disabled If enabled allows base station to enable or disable audible sound 30 SEC LED CLR on off If on maintenance led s on ESC 864 will go out after 30 se
12. ssary to access an 864 Series Remot Station Controller s programming routines how the routine s entry is displayed how to enter a new entry and verify the entry Programming Operation I Install MDK 864 to Remote Station Controller using installation procedure See Section 4 1 De Enable EEPROM E2 jumper on Remote Station Controller PC board 3 Depress the SEL PROG key 4 Using keys 1 9 amp A C select program routine or function to be displayed or reprogrammed Bre If a new function is to b inserted depress CLEAR key Clears display to all zeros 6 Enter the new function or program value with the numeric keyboard 7 Turn on the Program Enable slide switch and verify tha the MDK 864 programing indicator light is on NOTE When in the programming mode the Controller will not accept any input commands from the RF link El 8 Depress PROG key new data will be stored in memory 9 Re select the function and verify that the new entry is displayed on the MDK 864 display 10 Turn off Program Enable slide switch TL Disable E2 jumper 12 Repeat steps 3 10 as necessary Note For accessing the siren tone cyclic timing program for mechanical sirens perform the following steps j Depress the SEL PROG key Za Depress the ENTER key 3 Using keys 1 8 select the tone for the cyclic timing to be programmed 4 Siren cyclic timing will be displayed in ON OFF timing dur