1. SolaPalm Lighting Unit Quick Guide Version 1 0 1 Package Contents You should have received the following items inside of package Lighting Unit External battery connector x 1 pc Quick Guide E27 lamp holder with 2 m cable x 1 pc 2 Product Overview Front View 1A 2A charger select CFL on off switch Charging status indicator Battery status indicator Fault indicator USB charger ports Main power switch oS T pe ae A amon PV input CFL output receptacles 12VDC output connector 2A AC fuse AC input oo ee eS External battery connector 3 Installation and Initial Startup NOTE Before installation please inspect the unit Be sure that nothing inside the package is damaged Placement amp Storage Conditions Install the unit in a protected area that is free of excessive dust and has adequate air flow Please place the unit away from other units at least 20 cm to avoid interference Do NOT operate it where the temperature and humidity is outside the specific limits Please check the specs for the limitations Connect to Utility and Solar Panel Before initial use please plug in the AC input cord If using solar power to charge please select suitable 24W solar modules and connect to PV input connector The spec for solar modules is listed below Recommended Power Max Open Circuit Voltage Max Input Current rating 24W 30 VDC When solar power is efficient it w
2. Turn on the unit by pressing the main power switch to RESET position At the moment the CFL output receptacles are not powered on yet but there will be output power on USB charger ports and 12VDC connector If connecting to utility before CFL output receptacles will be automatically turned on If not please press CFL On Off switch to turn on the CFL output receptacles Turn off the unit by pressing again the power switch eration Condition Indicators Table for O Charging indicator Battery Battery power is sufficient Yellow LED lighting status Battery power is low indicator Yellow LED flashing indicator 4 Important Safety Warning SAVE THESE INSTRUCTIONS CAUTION To prevent the risk of fire or electric shock install in a temperature and humidity controlled indoor area free of conductive contaminants See the specifications for the acceptable temperature and humidity range CAUTION To reduce the risk of overheating the unit do not cover the cooling vents of this unit and avoid exposing the unit to direct sunlight or installing the unit near heat emitting appliances such as space heaters or furnaces CAUTION Do not attach non computer related items such as medical equipment life support equipment microwave ovens or vacuum cleaners to the unit CAUTION Do not plug the unit input into its own output CAUTION Do not allow liquids or any foreign object to enter inside of this unit Do not place bevera
3. ed handles 3 Wear rubber gloves and boots 4 Do not lay tools or metal parts on top of batteries 5 Disconnect charging source prior to connecting or disconnecting batteries terminal Condition Visual Condition __ status 5 Trouble Shooting Use the table below to solve minor problems Possible Cause Solutions _ _ Low battery Charge the unit at least 8 hours type of battery on the unit No solar energy input Wires are not firmly Check if all wires are connected during daytime connected properly Problem dealer to replace solar modules Battery defect It might be Replace the battery with the same due to high temperature type of battery operation environment or improper operation to battery Back up time is shorten 6 Specifications Model _ __ _ _ Lighting Unit Voltage 230VAC Voltage Range 100VAC 300VAC Frequency Max DC Power Max DC Voltage Rated Power Voltage DC OUTPUT USB 5V 1A DC Connector Type amp Number 12 V 7 Ah x 1 Built in External battery bank Charging Time Dimension DxWxH Net Weight kgs Environment gt a O 0 40 C non condensing
4. ges or any other liquid containing vessels on or near the unit CAUTION In the event of an emergency press the OFF button and disconnect the power cord from the AC power supply to properly disable the unit CAUTION Do not attach a power strip or surge suppressor to the unit Attention hazardous through electric shock Also with disconnection of this unit from the mains hazardous voltage still may be accessible through supply from battery The battery supply should be therefore disconnected in the plus and minus pole at the quick connectors of the battery when maintenance or service work inside the unit is necessary CAUTION Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions Keep unauthorized personnel away from batteries CAUTION When replacing the batteries use the same number and type of batteries CAUTION Internal battery voltage is 12VDC Sealed lead acid 6 cell battery CAUTION Do not dispose of batteries in a fire The battery may explode Do not open or mutilate the battery or batteries Released electrolyte is harmful to the skin and eyes CAUTION Unplug the unit prior to cleaning and do not use liquid or spray detergent CAUTION A battery can present a risk of electric shock and high short circuit current The following precaution should be observed before replacing batteries 1 Remove watches rings or other metal objects 2 Use tools with insulat
5. ill use solar power to charge battery first Please refer to below table to select charging current Using built in Using external Charging current batte batte Utility onl 2A Solar power 24W 2 A 2 A Real charging current may be changed according to spec of solar panel Connect to External Battery Bank and Charging If the model is already built in battery and applying external battery at the same time please use same brand and same spec of inside battery Assemble external battery connector with battery cable Then simply plug external battery bank to the unit For the best results Suggest to charge battery at least 8 hours before initial use Connect the Load There are three kinds of output connectors for different devices Please follow below instructions to connect suitable loads to the unit CFL Output Receptacles Plug in the bundled lamp cable to output receptacle on the rear panel of the unit Built in power switch in cable is to control power for lamp holder with utility connection There are three output receptacles on the rear panel of this unit to support up to 3 CFL lamps at the same time USB Charger Ports Plug your mobile phones devices into USB charger ports Then your devices will start to be charged when this unit is powered on You also can connect two USB charger ports into one 2Amp charger port 12VDC Output Connector This output connector is for LED bulb lighting or DC fan Turn On Off the Unit