Home
NCT240 IP DSLAM with IAC3000 VLAN Tagging
Contents
1. a Intranet Tagged mmm Port 1 Room101 Port 24 Room 24 are with its individual 802 10 VLAN tag to the IAC3000 es Tagged Figure 2 802 1Q VLAN Tagging relationship between NCT240 and IAC3000 Service Zones The IAC3000 support 9 different service zones the default service zone service zone 1 to 8 The two system modes for service zones are Port Based Mode and Tagged Based Mode The default service zone is always enabled in both modes SZ1 to SZ8 are disabled by default and require the administrator to enable it and make necessary configurations when needed Each SZ configuration page is a Summarized page that consists of hyperlinks to its sub configuration pages The settings that you can make in a SZ configuration are service Zone Status Service Zone Name Service Zone VLAN Tagged Number required in tagged based mode Service Zone Mgmt IP address Service Zone DHCP Server Relay Service Zone Authentication Setting Options Which Authentication server to be used in this SZ Service Zone Authentication Setting Options gt Configure Authentication Server s Service Zone Custom Pages this means every SZ in the AC3000 can have its own custom login logout pages the custom pages include PLM user charge free login pages Service Zone Group Configuration Bandwidth QoS NetComm NCT240 V3 0 9 IP DSLAM VLAN Tagging with I AC3000 Configuration Instruction Last updated on Feb2010 Page 4 e Service
2. Group 1 Traffic Configuration details are shown as follows NetComm NCT240 V3 0 9 IP DSLAM VLAN Tagging with AC3000 Configuration Instruction Last updated on Feb2010 Page 24 Traffic Configuration Group 1 Traffic Configuration Traffic Class BestEffot iv Group Total Downlink 54 Mbps Individual Maximum Downlink Individual Request ema 512 Kbps Group Total Uplink 54 Mbps Individual Maximum Uplink Individual Request Uplink 512 Kbps You will then map Group 1 Policy 1 and S21 together Group Configuration Sontiguration Group 1 Select Group QoS Profile Privilege Profile Remark Name Enabled Policy Edit Group Permission Default Step 5 7 Configure Policy 1 for SZ1 for Session Limit Control Group Permission for this Service Zone Default Policy in this Service Zone Policy Edit System Policies Email Message for Login Reminding S Edit Mail Message Disable NetComm NCT240 V3 0 9 IP DSLAM VLAN Tagging with AC3000 Configuration Instruction Last updated on Feb2010 Page 25 Step 5 8 Configure Policy 1 settings Click Edit System Policies under SZ1 to configure set tings Change the user session limit from 500 to 50 and click Apply The default val ues are used under Firewall Profile Specific Route Profile and Schedule Profile in this white paper Firewall Profile Route Profil
3. http www netcomm com au support for more details Configure I AC3000 system information NetComm NCT240 V3 0 9 IP DSLAM VLAN Tagging with AC3000 Configuration Instruction Last updated on Feb2010 Page 11 Mel LLM j IAC3000 Internet Access Controller MIA TOCOL COOL at User AP Management Configuration Wizard system Information WANA Configuration j WAN2 Configuration Configuration WAN Traffic Settings System Name Information Device Name Portal URL Address List SNMP User Logon SSL Time Access History IP Administrator Contact ey System Information System Information Netlomm IAC3000 Network Administrator Phone Number Po C Use the name on the security certificate FQDN for this device Enabled Disabled httovwww enetcomm com au e g hthos www google com Peg t92 108 2 0 setup Management IF Address List O Enabled Disabled Enabled Disabled Device Time 2009 09 03 12 07 31 Time one GMT 10 00 Canberra Melbourne sydney NTP Enable NTP Server 4 ntp1 cs mu OZ AU e g tock usno navy mil NTP Server 2 tock usno navy mil NTP Sever 3 ntp1 fau de NTP Server 4 clock cuhk edu hk NTP Server iTi ntpa1 pads ufrj br Set Device Date and Time NetComm NCT240 V3 0 9 IP DSLAM VLAN Tagging with AC3000 Configuration Instruction Last updated on Feb2010 Page 12 kkkkkk
4. Port Mapping Charge Login Page Welcome to User Login page Please enter your user name and password to sign in Username Password Remaining Remember Me Port Mapping Free Login Page Preview Welcome To Broadband Internet Service Please click the CONFIRM button to accept the terms and conditions above or click CANCEL to exit Port Mapping Charge Login Page Preview NetComm NCT240 V3 0 9 IP DSLAM VLAN Tagging with AC3000 Configuration Instruction Last updated on Feb2010 Page 23 Welcome to Broadband Internet Service Please choose from the following service selection Plan Price 1 hr s 5 4 hris 18 48 hris 32 120 hris 60 168 hris f4 1000 Mbytefs 65 Until 22 00 12 O O O O O Service Agreement Please kindly note that there will be no refund once connectivity is confirmed Please click CONFIRM to acceptthe usage charge or CANCEL to exit The selected service charge will be posted directly into your guest folio lf you already have an user account please click here to login Step 5 6 Configure Group 1 to map to SZ1 for user bandwidth management Group Permission for this Service Zone Default Policy in this Service Zone Policy 1 Edit System Policies Email Message for Login Reminding Habe Se Disable Click on Configure gt Group 1 gt QoS Profile gt and map Group 1 bandwidth control to policy 1 and SZ7 The
5. ST 0 R E Specials on products and accessories NetComm provides broadband internet solutions that Enable dial up ADSL wireless broadband or 3G mobile broadband connection Provide wireless internet access for customers Reduce telephone costs with VolP Voice over Internet Protocol m Connect protect and control your computer network International a a a a A a hap PRI EEN ESENE Inquiry Gals liane NetComm NCT240 V3 0 9 IP DSLAM VLAN Tagging with IAC3000 Configuration Instruction Last updated on Feb2010 Page 40 Appendix A How to check current user list in the IAC3000 There are two ways to check the current VLAN user list in the IAC3000 system Method 1 Navigate to System gt Configuration gt Port Mapping gt Port Location Mapping List gt Click View then click on 102 to view current status Network Configuration t9 Port Location Mapping List Configuration Wizard Add Port Mapping System Information WAN1 Configuration Port Location Mapping List VLAN ID Room Num State Description omg Delete All VIP Room Free of Charge WAN Configuration Room Delete WAN Traffic Settings Roami02 oe Delete LAN Port Mapping 10 Roomi03 Charge 5 Delete 10 Roomi04 Charge 521 Delete Port Mapping B 105 Roomi05 Charge S521 Delete 106 Roomi06 Charge of 1 Delete NetComm NCT240 V3 0 9 IP DSLAM VLAN Tagging with AC30
6. Server 4 LDAP idap o On demand U ONDEMAND ondemand SIP SIP N A l i Fort Mapping Free Login Page Port Mapping Charge Login Page Logout Page Custom Pages Login Success Page Configure ig Login Failed Page Configure l Login Success Page for On demand User Configure Logout Success Page Configure Logout Failed Page Configure NetComm NCT240 V3 0 9 IP DSLAM VLAN Tagging with IAC3000 Configuration Instruction Last updated on Feb2010 Page 18 Group Permission for this Service Zone Default Policy in this Service Zone Policy 1 jw Edit System Policies Email Message for Login Reminding eEnable Eaimaihess age Disable Wireless settings Set 510 NetComm IAC3000 1 Open system Authentication l Access Point Security L Enable 802 1 Authentication Encryption Managed AP in this Service Zone IP Address AP Type AP Name Status MAC Address You should restart the system to activate the changes Restart Click the Apply button to apply new settings to SZ1 Click on Restart to restart the system to make new changes to take effect Step 5 2 Reboot the system to make SZ1 changes effective IAC3000 system reboot generally takes 100sec to complete Once the system has finished rebooting you should see the SZ1 overview page shown as follows Re login to IAC3000 using the new admin password navigating to System Configuration gt Service Zone it is
7. Zone Policy Configuration FW Rule Route Rule Session Limit e Service Zone APs central management By default under Tagged based Mode each SZ has its pre assigned VLAN tagged number 1 to 8 See screen shot below Y 7 Wa f Network r Utilities Status J Authentication Management _ Configuration Service Zone Settings Configuration Wizard i Service Zone Settings cnn one VLAN ggp WLAN Applied Defaut status Details Hire Tag Encryption Policy Authentication ee WAN Configuration z Netcom Default mJAC3 None Policy1 Server Enable WAH Configuration ooo NetCom i WAN Traffic Settings S71 1 mJAC3 None Policy1 Severi Disable 000 1 LAN Port Mapping Netcom S22 2 mJAC3 None Policy1 Semeri Disable 000 2 Netcom Sz3 3 mJAC3 None Policy1 Severi Disable 000 3 Netcom SZ4 4 mJAC3 None Policy1 Sewer Disable 000 4 Netcom SZ5 5 mJAC3 None Policy1 Semeri Disable 000 5 NetCom S26 6 mJAC3 None Policy1 Severi Disable 000 6 kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk Note The Service Zone VLAN tagged number is used to identify the Service Zone Please do not use the same VLAN tagged number in the PLM configuration kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk VLAN VLAN stands for Virtual Local Area Network It is a g
8. gt Tagged based NetComm NCT240 V3 0 9 IP DSLAM VLAN Tagging with I AC3000 Configuration Instruction Last updated on Feb2010 Page 15 service Zone Port Role Setting Select Service Zone Mode Port Based O Tag Based In tag based mode every port maps to every Service Zone LANS LANG LAN LANG LANA LAN LANS LAN4 Step 5 Configure Service Zone settings Step 5 1 Click on Configure button to configure S271 Perform the following configurations to SZ1 a Change the VLAN tagged number from 1 to 10 for SZ1 b Configure IP Address DHCP server DHCP server pool and DNS details for S21 c Configure on demand billing plans under on demand user server d Configure custom login pages e Configure PLM charge login page f Configure PLM free login page g Configure User Group for SZ1 bandwidth control h Configure User Policy for SZ1 user session limit Warning Please make sure the VLAN tagged number of the service zone and the port location VLAN room number are unique in the AC3000 system for the Port Location Mapping to work properly They should not share the same VLAN tagged number kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk NetComm NCT240 V3 0 9 IP DSLAM VLAN Tagging with IAC3000 Configuration Instruction Last updated on Feb2010 Page 16 Navigate to System Configuration gt Service Zones gt SZ1 to configure SZ7 basic settings The are
9. please click on View under Port Location Mapping List User Port Mapping Quick Setup VLAN ID Start How many VLAN Room Number Start Room Prefix Room Postfix Room Default State Charge Free Block service Zone SZ Room State Charge Free Block Service one Change VLAN ID Room Number Room Default State Charge Free Block Room Description Po service Zone SZ se Hilitie gt Port Location Mapping Configuration Wizard Port Location Mapping WAHT Configuration WAN Configuration WAN Traffic Settings LAN Port Mapping Service Zones Port Mapping l Port Location Mapping List View NetComm NCT240 V3 0 9 IP DSLAM VLAN Tagging with AC3000 Configuration Instruction Last updated on Feb2010 Page 29 Port Location Mapping List VLAN ID Room Num State Description iea Delete All 101 Roomiot Charge S71 Delete 102 Roomi0 charge Delete 103 Roomi0s Charge 521 Delete 104 Roomi04 Charge S71 Delete 105 Roomi0s Charge Delete 106 Roomi06 Charge oe I Delete 107 Roomio7 Charge S71 Delete 108 Roomios Charge 371 Delete 109 Roomi0g Charge 571 Delete 110 Room1i0 Charge S71 Delete Total 4e First Prev Next Last kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk Note Room description cannot be added via Batch C
10. presented with the user login page again and if you click confirm the Room 102 PMS billing data will be re sent with a different set of user name and password Welcome to Broadband Internet Service Please choose from the following service selection Plan Price 1 hris 5 24 hr s 18 48 hr s 32 120 hr s 60 168 hr s 74 1000 Mbyte s 65 Until 22 00 12 O O O O Service Agreement Please kindly note that there will be no refund once connectivity is confirmed Please click CONFIRM to acceptthe usage charge or CANCEL to exit The selected service charge will be posted directly into your quest folio CONFIRM NN XX CANCEL Ifyou already have an user account please click here to login NetComm NCT240 V3 0 9 IP DSLAM VLAN Tagging with AC3000 Configuration Instruction Last updated on Feb2010 Page 45 NetComm NCT240 V3 0 9 IP DSLAM VLAN Tagging with AC3000 Configuration Instruction Last updated on Feb2010 Page 46
11. 00 Configuration Instruction Last updated on Feb2010 Page 41 4 Port Mapping Profile Fort Mapping Frofile VLAN ID 102 Room Number Roomi02 Room State Free Charge Block Room Description Service one Room Available a User Name Password zah maofsee5d Plan Type TIME Plan Quota Remaining Quota 1 hris User Account Status Reference You will notice that Room 102 is currently Online kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk Note The Remaining Quota shown under VLAN rooms will only updated after guest user has logout or click logout button on the success user login page window kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk Method 2 Another way to view the current user list in the IAC3000 is by navigating to Status gt Current Users gt Current Users List NetComm NCT240 V3 0 9 IP DSLAM VLAN Tagging with AC3000 Configuration Instruction Last updated on Feb2010 Page 42 Configuration J Authentication dJ Configuration Username Pkts In Bytes In Location Pkts Out Bytes Out Kick Out zahbi NetlComm 192 168 31 74 OQO1E 68 AC 0E 94 s f Refresh Appendix B How to delete a VLAN roaming account NetComm NCT240 V3 0 9 IP DSLAM VLAN Tagging with AC3000 Configuration Instruction Last updated on Feb2010 Page 43 When a VLAN
12. 18 Postfix R2T8 of the modem router NB6plus4 R278 is referring to a modem router that is running bridge mode hotel firmware It acts as a plug and play device to convert ADSL signals to Ethernet signals GE It stands for Gigabit Ethernet It is the standard for a high speed Ethernet It has a maximum data transmission rate of 1000Mb s or 1 Gigabit s xDSL It is refer ADSL in this document It covers ADSL ADSL2 and ADSL2 unless otherwise indicated IAC3000 VLAN Management The IAC3000 offers two methods of connection Users can either be issued a unique user name and password or using VLAN tagging the Port Location Mapping Feature in the IAC Rooms can then be recognized via its room number Both options offer zero configurations for subscribers hotel room guests Guests simply plug the Ethernet cable into their laptop enter a username and password or simply accepts the terms and conditions and they are connected without changing any settings at all This NetComm NCT240 V3 0 9 IP DSLAM VLAN Tagging with AC3000 Configuration Instruction Last updated on Feb2010 Page 3 white paper will focus on the configuration for setting up VLAN tagging the port location mapping function of the IAC3000 ADSL 2 Lines Port 1 Port Port 3 Port 24 IAC3000 keeps a record of the VLAN database that set in the IP DSLAM IAC3000 Gateway Modem Router INTERNET me o ff fi Network FIT IP DSLAM Y
13. ID room is activated at the same time the mapping On demand account is creates in the IAC3000 on demand user server In situations where the administrator needs to delete the user name and password that mapped to the VLAN ID room 102 here are the steps to follow Step 1 Navigate to User Authentication gt Authentication Configuration gt On demand User server gt On demand account list gt click view Configuration J System Configuration 9 Authentication Configuration Authentication Server Configuration Black List Configuration Server Name Auth Method Postfix Group server POPS pops Group 1 Policy Configuration E server RADIUS radius Group 1 i Net Retriever Semer 4 LDAP ldap Group 1 aerate TSE On demand User ONDEMAND NetComm Group 1 SIP SIP NIA None Authentication Server On demand User beneral Settings Configure Ticket Customization configure Billing Plans configure External Payment Gateway Configure On demand Account Creation Click Delete to delete the user name and password that mapped with Room 102 On demand Account List Username Password Remaining Quota Status Reference Delete All zah mog See5d 16 mints Normal roomN Room102 NetComm NCT240 V3 0 9 IP DSLAM VLAN Tagging with AC3000 Configuration Instruction Last updated on Feb2010 Page 44 When you try to access the internet from room 102 now you will be re
14. NB6plus4_R2T8 to an ADSL Port of the NCT240 DSLAM system The ADSL data point socket in the guest room and wait for ADSL light on the test modem turn solid green Step 2 Connect the test PC to the LAN Port of the test modem Note TCP IP setting of the PC is to be set to obtain IP Address DNS address from DHCP server automatically Step 3 Wait for a valid IP address assigned by the IAC3000 to your subscriber PC Guest room PC En x General Support Connection status elt Address Type Assigned by DHCP H IP Address 192 168 31 74 Subnet Mask 256 255251 Default Gateway 192 168 31 1 Windows did not detect problems with this connection If you cannot connect click Repair NetComm NCT240 V3 0 9 IP DSLAM VLAN Tagging with IAC3000 Configuration Instruction Last updated on Feb2010 Page 35 Once a valid IP address is received by the subscriber guest room PC you then open Internet Explorer Attempt to access the Internet by browsing a website If PLM has been setup correctly the following page will be presented You will then need to select and accept the Internet access conditions and hit Enter then OK to proceed Step 3 1 If you are testing from a free of charge VIP room for example Room 101 you will expect to see the following login page Welcome To Broadband Internet Service Please click the CONFIRM button to accept the terms and conditions above or click CANCEL to exit Cli
15. NELLOMMT Broadband Solutions NCT240 IP DSLAM with IAC3000 VLAN Tagging Implementation The NetComm NCT240 24 Port IP DSLAMs support 802 1Q VLAN Tagging This white paper is written to assist IP DSLAM system integrator to set up and configure NetComm s NCT240 IP DSLAMs running firmware version V3 0 9 to work with an IAC3000 Internet Access Controller for Internet access and billing application using the VLAN Tagging and Port Location Mapping It is recommended that the readers of this document has read and understood the Installation Guide and User Manual of the NCT240 IP DSLAM The NCT240 IP DSLAM combined with an IAC3000 offers two methods of connection User can either be issued with a unique user name and password which is required on log in or using VLAN tagging and the Port Location Mapping Feature in the I AC3000 Rooms can then be recognized via its room number Both options in the IAC3000 offer zero configurations for subscribers hotel room guests Guests simply plug the Ethernet cable into their laptop enter a username and password or simply accepts the terms and conditions and they are connected without changing any settings at all Figure 1 illustrates the logical network diagram for NCT240 IP DSLAM working with an IAC3000 NetComm NCT240 V3 0 9 IP DSLAM VLAN Tagging with AC3000 Configuration Instruction Last updated on Feb2010 Page Logical Network Diagram Say ADSL Modem Routdr DHCP Server WAN to modem
16. a that requires attention is highlighted by red boxes in the screen shot below Please make sure the valid DNS server addresses are used for Prefer DNS server and the alternate DNS server The detail setting for authentication servers custom pages group and policy settings will be described later in this section Management j Configuration Service Zone Settings Service Zone Status Enable O Disable 4 i Authentication Configuration Wizard Basic Settings System Information WAN4 Configuration Service Zone Name Bly range 1 4094 WAH Configuration Operation Mode NAT Router WAN Traffic Settings Network Settings IP Address 192 168 31 1 LAN Port Mapping Subnet Mask 255 255 255 0 Service Zones Disable DHCP Server M Port Mapping Enable DHCP Server Start IP Address 192 168 31 2 End IF Address 192 166 317 200 DHCP Server Settings Domain Name domain WINS Server IP Lease Time 1Day Reserved IP Address List Enable DHCP Relay NetComm NCT240 V3 0 9 IP DSLAM VLAN Tagging with AC3000 Configuration Instruction Last updated on Feb2010 Page 17 SIP Interface Configuration Enabled WAN Interface WANI Authentication Settings Enable O Disable Auth Option eee Postfix Default Enabled Server 4 LOCAL local Serer POP3 pops O F Authentication Options Server 3 RADIUS radius O F
17. anAdvSetting VlanBasicSettinc DeviceID U TargetID U Refresh m ol i ollollo icliocolieioicicoicicic m m m m Ola alan al lN j e ololololololololo Sel clloliciclilol oliicliclolicliciiolic oio o o o rsio io o o o o co NO NO NO NO NO N A uo el WN l e ojo 9 o NetComm NCT240 V3 0 9 IP DSLAM VLAN Tagging with IAC3000 Configuration Instruction Last updated on Feb2010 Page 8 Step 2 Navigate to Home gt Configuration gt Save gt click on Save then Ok Address http 192 168 1 1 main html Broadband Access Switch Home System tes eas DeviceID 0 TargetID 0 ADSL I Switch Status Save changes to flash ESE m IF Microsoft Internet Explorer Eg ma ma Performance Statistics m l Configuration 3 2 NetComm NCT240 V3 0 9 IP DSLAM VLAN Tagging with AC3000 Configuration Instruction Last updated on Feb2010 Page 9 Part 2 IAC3000 Port Location Mapping Configuration Overview Part 2 describes how to configure the AC3000 for Port Location Mapping application with PMS billing integration The logical order of configuration described in this section is as follows Configure I AC3000 system information Configure administration accounts Configure WAN 1 WAN 2 and WAN traffic load balancing settings Configure system to tag based mode Configure service zone SZ settings Configure on demand billing plans under on dem
18. anagement Ay Walled Garden List Walled Garden List Privilege List liem Address Item Address Monitor IP List l i www netcomm com au Lp Walled Garden List lt a Fic ork Address Translation Navigate to Network Configuration gt Walled Garden Ad List gt add www netcomm com au as a free website to display at the user login page and click Display and Apply See screen shot below for details O System Configuration Authentication Management fA Walled Garden Ad List Walled Garden Ad List URL Topic Description htp Awww netcomm com au NetComm Limited Utilities Broadband Solutions Th Waled Garden Ad List IP Mobility f VPN Configuration i http www netcomm com au Topic NetComm Limited Description Broadband Solutions You have now completed setting up the IAC3000 for user free and user charge application using Port Location Mapping VLAN tagging Default SZ and SZ1 are now both set up and enabled in the IAC3000 system ready for PLM user NetComm NCT240 V3 0 9 IP DSLAM VLAN Tagging with AC3000 Configuration Instruction Last updated on Feb2010 Page 34 Part 3 Test and verify the port location mapping function of the IAC3000 and NCT240 system Connect the Bridged NB6plus4_R2T8 to the line tails of the NCT240 line port 1 connect the GE1 of the NCT240 to the IAC3000 LAN port Steps and Procedures Step 1 Connect the test modems
19. and user server Configure custom login pages Configure group and policy setting for user bandwidth control Configure port location mapping VLAN entries and map to the appropriate service zone e Configure NetRetriever parameters for PMS billing integration IAC3000 described in this white paper will have two service zone enabled The two service zones are the default SZ 192 168 30 1 24 and SZ 1 192 168 31 1 24 Default service zone provides user login page for untagged traffic and for VLAN account roaming purposes SZ1 is set up for Port Location Mapping VLAN users The default service zone is enabled by default but SZ1 and its configuration will require administrator configuration details are discussed in the next section NetComm NCT240 V3 0 9 IP DSLAM VLAN Tagging with AC3000 Configuration Instruction Last updated on Feb2010 Page 10 Steps amp Procedures Step 1 Connect an Ethernet cable to one of the LAN port of the I AC3000 Open the IAC3000 web management interface by using the following login details Default LAN Mgt IP address http 192 168 30 1 Default admin user name admin Default admin Password admin This document is being created at a time when the following version of firmware was in production e AC3000 Firmware V2 00 01_ 01000 Please make sure the IAC3000 is running the firmware V2 00 01_01000 or later to use port location mapping feature For more details please visit the NetComm website
20. and will be tagged as they leave the uplink of the NCT240 IP DSLAM NCT240 will both admit untagged and tagged packets Repeat the above VLAN configuration to create VLAN 101 VLAN 124 for all the 24 ADSL Ports in the NCT240 Example refer to screen shot for VLAN 102 configuration shown as follows NetComm NCT240 V3 0 9 IP DSLAM VLAN Tagging with IAC3000 Configuration Instruction Last updated on Feb2010 Page 7 Address http 192 168 1 1 main html Home System ADSL Switch VLAN EthPortsetting MAC IGMP Snooping IGMP Group List 602 1 QueueMapn DHCP Relay Option82 LoopTest ESTP tatus P Performance a 3 3 3 3 3 3 3 3 3 3 I Statistics Configuration v E co Links 7 Broadband Access Switch Home Logout VLAN Basic Setting DeviceID 0 TargetID 0 Basic VLAN Setting 12 RETOR METE oe WwW ag 1 i VLAN SwitchMode VLAN FrameType Admit both untagged and tagged packets b Apply To view the current VLAN setting click on DisplayVLANSettings to view the current VLAN information for all the 24 ADSL ports Address http 192 168 1 1 main html v E co Links Home System ADSL Switch VLAN EthPortsetting MAC IGMP Snooping IGMP Group List 802 1x QueueMap DHCP Relay Optiong2 LooptTest RSTP status E 3 3 6 2 6 6 6 2 6 6 I Performance Statistics Configuration Broadband Access Switch Display VLAN Setting X i Vl
21. apacity Gigabit Ethernet uplinks andaggregates manages 24 ADSL ADSL2 interfaces on user side in a singlerack unit package The ADSL interface complies with ITU iG 992 1 G dmt G 392 2 G lite 3592 3 ADSL and G 992 5 ADSL2 standards and connects up to 24ADSL2 2 modems ATU R casso E Navigate to Home gt Switch gt VLAN gt Basic VLAN Settings gt Refer to settings as shown then click Apply then OK gt VLAN Switch Mode gt Refer to settings as shown then click Apply then OK gt VLAN Frame Type gt Refer to settings as shown then click Apply then OK NetComm NCT240 V3 0 9 IP DSLAM VLAN Tagging with IAC3000 Configuration Instruction Last updated on Feb2010 Page 6 Address http 192 168 1 1 main html Broadband Access Switch DeviceID 0 TargetID 0 VlanAdvsSetting DisplayVlanSettine Basic VLAN Setting Default VLAN Priority MinPortID PVC ID MaxPortID PVC ID 10 o 2095 CE VLAN SwitchMode Forwarding by MAC only ginu VLAN FrameType 3 11 amp 3 3 amp 3 3 amp 3 5 3 p m status PE 2 PVC Performance FrameT ype MinPortID ID MaxPort ID ID statistics Configuration Admit both untagged and tagged packets v Apply Microsoft Internet Explorer Eg A WLON Set OKI Microsoft Internet Explorer By following the above settings it means that ADSL port 1 PVC1 8 35 packets are to be assigned with a VLAN 101 number
22. ck on CONFIRM to surf the Internet To log out please click the Logout button Remaining Usage Expiration time 2009 09 09 14 30 Login time 2009 9 4 12 9 44 start Browsing Step 3 2 NetComm NCT240 V3 0 9 IP DSLAM VLAN Tagging with AC3000 Configuration Instruction Last updated on Feb2010 Page 36 If you are testing from a user charge room you will expect to see the following login page Welcome to Broadband Internet Service Please choose from the following service selection Plan Price 1 hres 5 24 hr s 15 46 hris 32 120 hr s 60 168 hr s fa 1000 Mbyte s 65 Until 22 00 12 O O O O O Service Agreement Please kindly note that there will be no refund once connectivity is confirmed Please click CONFIRM to acceptthe usage charge or CANCEL to exit The selected service charge will be posted directly into your quest folio CONFIRM fe X CANCEL lf you already have an user account please click here to login NetComm NCT240 V3 0 9 IP DSLAM VLAN Tagging with I AC3000 Configuration Instruction Last updated on Feb2010 Page 37 Hello you are logged in via zahb NetComm password mg deedd 59 Minj52 Seg Login time 2009 9 4 12 29 23 Stat Browsing kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk Note The user name and password presented in the user login success page for example za
23. e and Schedule Profile should be site specific For more details please refer to the IAC3000 User Manual Policy Configuration Policy 1 select Policy Policy 1 Step 5 9 There is no Managed Access Point required in this PLM test so we won t make changes to Wireless Settings and Managed AP in this Service Zone Wireless Settings Set SSID Netlomm IACSO00 1 Open System Authentication Access Point Security LJ Enable 802 1X Authentication Encryption Managed AP inthis Service Zone IP Address AP Type AP Name Status MAC Address Click Apply to apply the new settings to SZ1 NetComm NCT240 V3 0 9 IP DSLAM VLAN Tagging with I AC3000 Configuration Instruction Last updated on Feb2010 Page 26 For instructions on how to configure AC3000 to centrally control and manage Net Comm NP725 and NP726 please refer to the product user manual and NetComm support website for more details Reboot the system to make the changes to take effect Once system finished reboot you should see that SZ1 overview page shown as follows Service Zone Settings Service VLAN a WLAN Applied Default as Tag aon Encryption Policy Authentication Name NetCom Default mJAC3 None Policy 4 Sever1 Enable O00 Netcom m_IAC3 Policy 1 server 1 Enable SA2 2 m_AC3 None Policy 1 Server 1 Disable Configure Netcom S73 3 m_ IAS Mone Policy 1 Server 1 Disable Configure 000 3 Netc
24. er provided by NetComm AR E3 ETSN e http www netcomm com auf x 4z ISHII Google IJE ZA a dada Pee L a 20088 ial File Edit iew Favorites Tools Help on gt we k Netcomm Australia Broadband Solutions Products A fy gt dh i Page Tools searceL XB powered by Bing Solutions O Services Support About NetGomm Resellers Only Investors Contact Us Register For Warranty Lill Click here now to register for warranty on any NetComm product hel ouam Drivers Firmware amp Troubleshooting ck here for the latest firmware Introducing the new Turbo 7 Wireless Gateway Where To Buy NetComm Click here to find out where you can i a buy NetComm products Broadband Solutions For Homes Businesses And ISP s Buy Online With over 25 years experience NetComm Limited is an award winning publicly listed Australian company dedicated to providing home y small office business Government and Internet Service Providers ISP s with broadband Internet products and services amp NetComm has recently introduced NetAssure a managed network service designed for small to medium businesses and has also expanded throughout the commercial and export markets With offices in Australia and New Zealand NetComm continues to provide the Australian and International market with leading data o o communication products mobile broadband solutions and networking services R T N 0 T T
25. expected that SZ1 is now enabled with VLAN tag number 10 NetComm NCT240 V3 0 9 IP DSLAM VLAN Tagging with AC3000 Configuration Instruction Last updated on Feb2010 Page 19 Ta s i TF a O 7 Cl r Utilities i Authentication Management Configuration Service Zone Settings Configuration Wizard service Zone Settings System Information gaaei VLAN can WLAN Applied Default Status Details on a Tag i Encryption Policy Authentication WAN4 Configuration WAH Configuration Default m_IAC3 server 1 Configure opg i Netcom 10 f m_IAC3 server 1 Configure O00 1 SA2 2 m_IACS3 None Policy 1 server 1 Disable Configure Netcom n i SA3 3 m_IAC3 None Policy 1 server 1 Disable Configure Step 5 3 Configure on demand account billing plans Navigate to System Configuration gt SZ1 and click on On Demand User server and navigate to Billing Plans to create your desired billing plans or navigate to User Authentication gt Authenti cation Configuration gt On demand User gt a 7 5 P 5 2 a F i i Network System Configuration Management Configuration ee Authentication Server Configuration Authentication Server On demand User General Settings Configure Ticket Customization Configure External Payment Gateway Configure On demand Account Creation On demand Accou
26. gateway IAC3000 Room 101 Port1 NCT240 IP DSLAM DSLAM Cable DSLAM Cable Port 1 24 Port 1 24 Subscribers Connect to MDF Hotel Room Users Figure 1 NCT240 with I AC3000 Internet Access Controller Terms amp Concepts PMS It stands for Property Management System Property management systems may be used in real estate logistics intellectual property or hospitality accommodation management They are computerised systems that facilitate the management of properties including maintenance legalities and personnel all through a single piece of software In this white paper it is referred to the software used by hotel motel service apartment to keep guest check in check out records and to produce billing invoices and receipts AAA It stands for Authentication Authorization and Accounting AAA management for computers to connect and use a network service NetComm NCT240 V3 0 9 IP DSLAM VLAN Tagging with AC3000 Configuration Instruction Last updated on Feb2010 Page 2 IAC It stands for Internet Access Controller it is referring to the NetComm IAC3000 in this white paper which is responsible for guest Internet AAA management control Net Retriever It is a middleware that acts as an interpreter to between the data that is outputted from the IAC system to the PMS server for billing purposes PLM It stands for Port Location Mapping It is an IEEE802 1Q VLAN tagging feature implemented in AC3000 R2
27. gt On demand User server gt General settings gt Postfix Netcomm NetComm NCT240 V3 0 9 IP DSLAM VLAN Tagging with AC3000 Configuration Instruction Last updated on Feb2010 Page 21 System Wi user Ya ap WO Network We Wiems Configuration AY Manageme F Configuration r A o Authentication Server General Settings Configure Ticket Customization configure Billing Plans Configure External Payment Gateway Configure On demand Account Creation Create On demand Account List System Wi 1E AP wi O Network F Ne Configuration do Manageme Configuration Utilities prr Authentication Configuration O None Susp O car O EuR Monetary Unit Input other desired monetary unit e g AU Group Name Grou D WLAN ESSID NetComm IAC3000 iora Contigaration wireless Key Remaining Volume Sync Interval 10mins 15min s 20min s Terminal Server Configuration X Cancel Cancel 1 Click Apply to apply the new postfix name Step 5 5 Configure SZ1 custom login pages Navigate to System Configuration gt Service Zones gt SZ1 gt Custom Pages NetComm NCT240 V3 0 9 IP DSLAM VLAN Tagging with AC3000 Configuration Instruction Last updated on Feb2010 Page 22 The default login pages are used by default A preview some the default login pages used are as follows Z Port Mapping Free Login Page
28. h6 NetComm mq78ee5d can be used by the user for account roaming This means this user name password is mapped to the same Room VLAN ID under the same internet usage account If the guest user uses this user name and password to access the Internet through wired or wireless area of the AC300 system they will be billed under the same guest account kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk Once Internet access is confirmed the billing data will be sent to the PMS system via the PMS Middleware It is important to verify the middleware NetRetriever parameter settings in the IAC3000 matched the settings in the NetRetriever server A billing log will then automatically generate and save locally in the IAC3000 system for system logging and tracking purposes Step 4 To view the PMS log login to the AC3000 management interface and navigate to User Authentication gt NetRetriever gt Event Log gt and click view NetComm NCT240 V3 0 9 IP DSLAM VLAN Tagging with AC3000 Configuration Instruction Last updated on Feb2010 Page 38 gt ae m a ia Hetwork Configuration J Management Configuration Net Retriever Configuration Connection Setup Event Log NetRetriever Configuration Net Retriever Event Log Date Size Byte 2009 09 04 127 Double click on the date and open the event log file You will notice the event
29. kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk Note Management IP Address Lis by default is set to allow IP address 0 0 0 0 0 0 0 0 to see the AC3000 web management interface this settings will be site specific It is recommended to only allow a specific IP address or a specific IP address range to access the AC3000 device management interface For example if you only allow the device management via the WAN interface you need to remove the 0 0 0 0 0 0 0 0 in the first entry and replace it with your desired IP address range eg 1 72 16 1 0 24 Please refer to the AC3000 user manual for more details kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk Step 2 Change IAC3000 administration password Navigate to Utilities gt Change Password gt change administrator manager and operator password Default Admin user name admin Default Admin password admin Default Manager User name manager Default Manager Password manager Default Operator User name operator Default Operator Password operator NetComm NCT240 V3 0 9 IP DSLAM VLAN Tagging with IAC3000 Configuration Instruction Last updated on Feb2010 Page 13 System j a a a i User AP Network Configuration Authentication Management j i Configuration Change Password Backup Restore Settings Old Password Firmware Upgrade New Passwo
30. log will keep a record of the VLAN room number date time of access user name password and price Please note that the Price shown in the log file is in a unit of cents That is 500 means 5 dollars or 500cents Net Retriever Billing Log 2009 09 04 2 r Room Cost Date Time Duration Description Name Bytes Us Roomi02 500 20090904 122922 000000 Room number Roomi02 plan 1 username zah6 NetComm password mq78ee5d price 500 NA 0 kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk Note If the following page is presented in the guest room instead of the login pages above then the setup for Port Location Mapping Billing is incorrect in the IAC3000 The VLAN settings in the device s might be incorrect Please review the configuration in the IAC3000 and the NCT240 VLAN settings NetComm NCT240 V3 0 9 IP DSLAM VLAN Tagging with IAC3000 Configuration Instruction Last updated on Feb2010 Page 39 Welcome to User Login page Please enter your user name and password to sign in Username Password mm Remember Me W NetComm Limited Broadband Solutions kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk Step 5 Surf the Internet Test complete Ee NetComm Australia Broadband Solutions Products And Services Microsoft Internet Explor
31. nt List NetComm NCT240 V3 0 9 IP DSLAM VLAN Tagging with AC3000 Configuration Instruction Last updated on Feb2010 Page 20 kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk Note IAC3000 Port Location billing is based on the on demand user server billing profiles This ts also the billing packages that will appear in PLM user login page In addition if the administrator chooses PLM user free implementation method when configuring port location mapping VLANs in the AC 3000 no billing data will be sent to the PMS server if the administrator chooses PLM user charge implementation method the re spective billing data will be sent to the PMS server kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk The following billing profiles are used in this white paper Billing Plans Billing Plans Plan Type Quota Price aun Enable L Privilege L Function 1 Time 1 hris 5 C 2 Time 24 hr s 18 F 3 Time 48 hr s 32 E 4 Time 120 hr s 60 E Additional Configuration 5 Time 168 hr s 74 o 6 Volume 1000 Mbytefs 65 F 7 Cutoff Until 22 00 12 C g NIA NVA 0 NVA Step 5 4 Configure Postfix The postfix for on demand user server can be modified to reflect the company or business names To configure on demand user server postfix navigate to User Authentication gt Authentication Configuration
32. om of4 4 m_IAC3 None Policy 1 Server 1 Disable Configure 000 4 Netcom 545 m IAS Mone Policy 1 server 1 Disable Configure 000 5 Netcom 5 6 6 m_lACsS None Policy 1 server 1 Disable Configure 000 6 Netlom Sif T m_IAC3 None Policy 1 server 1 Disable Configure 000 7 Netcom 5 6 E m IACS Mone Policy 1 server 1 Disable Configure 000 8 Step 6 Configure Port Location Mapping VLAN table Navigate to System Configuration gt Port Mapping gt Port Mapping Quick Setup Refer to screen shot below NetComm NCT240 V3 0 9 IP DSLAM VLAN Tagging with IAC3000 Configuration Instruction Last updated on Feb2010 Page 27 U AP Network Ser We Hhtes 5 z Authentication Management Configuration PWN ae Port Location Mapping Port Location Mapping WAH Configuration WAN Traffic Settings C Port Mapping Please note you can single create or batch create PLM VLAN entries The Batch Create method is used in the white paper The following screen shot illustrates how to batch create VLAN 101 to VLAN 148 entries in the IAC3000 NetComm NCT240 V3 0 9 IP DSLAM VLAN Tagging with IAC3000 Configuration Instruction Last updated on Feb2010 Page 28 Port Mapping Quick Setup 3 Configuration Wizard System Information WAN Configuration WAN2 Configuration Create Batch WAN Traffic Settings Ty ne Change All Room State Add One To view the PLM table
33. omm NCT240 V3 0 9 IP DSLAM VLAN Tagging with AC3000 Configuration Instruction Last updated on Feb2010 Page 31 Please reboot system to make PLM entries to take effect Step 7 Configure NetRetriever settings for PMS billing integration This step is only applicable to scenarios where you need to integrate the billing data from the IAC3000 to PMS system kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk Note IAC3000 supports PMS billing integration via middleware called NetRetriever via IP connection Please make sure the NetRetriever parameter settings in the IAC3000 matches the settings in the NetRetriever software You may need to work with a Ne tRetriever engineer to complete the AC3000 PMS billing integration set up kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk Note IAC3000 keeps a record of the billing data locally If no PMS integration is required you may make use of the local billing data and produce internet usage billing report in your own format To see the billing data please navigate to User Authentication gt Net Retriever gt Event Log or navigate to Status gt Traffic History gt On demand User Log kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk To config
34. rd C TTi Verify Password Gy Network Utilities New Password 5 verify Password Change Operator Password New Password j verify Password Step 3 Configure WAN 1 WAN 2 and WAN traffic load balancing settings a Navigate to System Configuration gt WAN 1 Configuration b Navigate to System Configuration gt WAN 2 Configuration c Navigate to System Configuration gt WAN Traffic Settings It is recommended to assign static IP addresses to the WAN interfaces of the AC3000 for device management purposes If there is only one WAN internet connection avail able steps b and c are not required Since the IP address details for WAN 1and WAN 2 are site specific they are not discussed in this whitepaper NetComm NCT240 V3 0 9 IP DSLAM VLAN Tagging with AC3000 Configuration Instruction Last updated on Feb2010 Page 14 Confiquration Wizard System Information WAHT Configuration WAN Configuration WAN Traffic Settings LAN Port Mapping Port Mapping Step 4 Configure and confirm that the IAC3000 is set to tag based mode By default the IAC3000 LAN Port Mapping is set to Tagged Mode To begin with it is assumed that you have performed a factory load default to the IAC3000 via the management interface Please verify IAC3000 is configured in VLAN Tagged Mode Navigate to System Configuration gt LAN Port Mapping gt Service Zone Mode
35. reate batch configuration kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk If there are VIP rooms that will not be charge for their Internet access charge mode can be changed to Free mode To change VLAN 101 Room 101 to User Free mode click on 101 hyperlink and change the Room state to Free add in Room Description such as VIP Room Free of Charge then click Apply to apply new settings for Room 101 NetComm NCT240 V3 0 9 IP DSLAM VLAN Tagging with AC3000 Configuration Instruction Last updated on Feb2010 Page 30 Port Mapping Frofile Room Number Roami04 Room State Free Charge Block Room Description VIP Room Free of Charge Service Zone oT Room Available User Name Password wo i xdvbadeg Plan Type CUTOFF Plan Quota NA Remaining Quota Until 2009 09 09 12 30 User Account Status Normal Reference roomN Roomi101 To view PLM table please click on View under Port Location Mapping List Port Location Mapping List VLAN ID Room Num State Description a Delete All i02 Roomi02 Charge S71 Delete 2 103 Roomi03 Charge S21 Delete 104 Roomi04 Charge S71 Delete 105 Roomi05 Charge of 1 Delete 2 106 Roomi06 Charge S21 Delete 107 Roomi07 Charge S71 Delete 108 Roomi0e Charge S71 Delete 109 Roomiog Charge S21 Delete 110 Roomiio Charge S71 Delete Total 48 First Prey Next Last NetC
36. roup of hosts with a common set of requirements that communicate as if they were attached to the same broadcast domain A VLAN allows a physical network to be divided into several logical networks An end device can be assigned to more than one VLAN group Devices from different VLANs cannot communicate with each other VLAN tags can be added to the MAC header to identify the VLAN membership of a frame across bridges A tagged frame is four bytes longer than an untagged frame NetComm NCT240 V3 0 9 IP DSLAM VLAN Tagging with IAC3000 Configuration Instruction Last updated on Feb2010 Page 5 Part 1 NCT240 VLAN Tagging Configuration There are 3 types of management interfaces available for NCT240 IP DSLAM system management The web management interface the CLI interface and the Telnet interface It is recommended to use the built in web management interface for NCT240 system configuration This white paper is written in the basis of using the web management interface of the NCT240 IP DSLAM Step 1 Connect the PC to the management port Manually configure your PC to 192 168 1 x address eg 192 168 1 2 24 Login to NCT240 web management interface Default IP address for ixp0 system management port 192 168 1 1 24 Default User Name admin Default Password admin Address http 192 168 1 1 cgi bin Baslogin cai v Eco Links The BAS Broadband Access Switch is an basic platform of Broadband IPSwitch that provides 2 high c
37. ure NetRetriever parameter settings navigate to User Authentication gt Net Retriever gt Connection Setup and fill in the parameter values required The parameter values shown below are only an example Please make sure the set tings in the NetRetriever software System ae wa AP wa Network aye Re Utilities Configuration Management Configuration AN F eee eee eee Oe tl Net Retriever Configuration Connection Setup Event Log NetComm NCT240 V3 0 9 IP DSLAM VLAN Tagging with I AC3000 Configuration Instruction Last updated on Feb2010 Page 32 Net Retriever Connection Setup secret NetlAcd 237 Net Retriever Server Port ERG NR ID 1 1 9999 GSDID 1 11 9999 Link Test Interval 60 20 800 seconds You should restart to activate this Click to restart Click Apply to apply the new settings Click Restart to reboot system Do you want to RESTART the system L Gre vou sure vou want to restart the system now S Configure IAC3000 Walled Garden List and Walled Garden Ad List Step 8 Navigate to Network Configuration gt Walled Garden List gt add www netcomm com au as a free access website and click Apply NetComm NCT240 V3 0 9 IP DSLAM VLAN Tagging with AC3000 Configuration Instruction Last updated on Feb2010 Page 33 System User AP Status Utilities Configuration Authentication M