1. p m 11 00AM 65 PGI MM PMSSY 09 10 N B 76 Watson Skin Grafting Knife Handle 2000 00 16 11 09 at 04 00 23 11 09 AT p m 11 00AM 66 PGI MM PMSSY 09 10 C 1 77 Nano Spectrophotometer 1800 00 16 11 09 at 04 00 23 11 09 AT p m 11 00AM 67 PGI MM PMSSY 09 10 C 1 47 Temporary Pacing Box 3500 00 16 11 09 at 04 00 23 11 09 AT p m 11 00AM 68 PGI MM PMSSY 09 10 C 2 05 Steam Sterilizer 6500 00 16 11 09 at 04 00 23 11 09 AT p m 11 00AM 69 PGI MM PMSSY 09 10 C 1 37 Sterilization amp Storage Container 5500 00 16 11 09 at 04 00 23 11 09 AT p m 11 00AM 70 PGI MM PMSSY 09 10 C 2 08 Electrocautery Argon Plasma coagulator 6000 00 16 11 09 at 04 00 25 11 09 AT p m 11 00AM 71 PGI MM PMSSY 09 10 C 2 09 Automatic Endoscopy washer Endoscope 150000 00 16 11 09 at 04 00 25 11 09 AT Disinfection System p m 11 00AM 72 PGI MM PMSSY 09 10 C 1 125 Laser Resectoscope Set 2000 00 16 11 09 at 04 00 25 11 09 AT p m 11 00AM 73 PGI MM PMSSY 09 10 C 1 120 Table Top Sterilizer 3000 00 16 11 09 at 04 00 25 11 09 AT p m 11 00AM 74 PGI MM PMSSY 09 10 C 1 112 Table top High Speed Refrigerated Micro 2000 00 16 11 09 at 04 00 25 11 09 AT Centrifuge p m 11 00AM 79 PGI MM PMSSY 09 10 C 2 17 MR Compatible Stereotactic Frame 12500 00 16 11 09 at 04 00 25 11 09 AT p m 11 00AM 76 PGI MM PMSSY 09 10 C 1 45 Walk In Cold Room 2500 00 16 11 09 at 04 00 25 11 09 AT p
2. 21 PGI MM PMSSY 09 10 N B 38 Paediatric Bronchoscope 3500 00 16 11 09 at 04 00 20 11 09 AT p m 11 00AM 28 PGI MM PMSSY 09 10 N B 39 Urodynamic Study Equipment 12500 00 16 11 09 at 04 00 20 11 09 AT p m 11 00AM 29 PGI MM PMSSY 09 10 N B 40 Ultrasonic Cutting amp Coagulating Device for 12500 00 16 11 09 at 04 00 20 11 09 AT open and laproscopic surgery p m 11 00AM 30 PGI MM PMSSY 09 10 N B 41 Instrument Washer amp Disinfector 4000 00 16 11 09 at 04 00 20 11 09 AT p m 11 00AM 31 PGI MM PMSSY 09 10 N B 42 Bilirubinometer 2000 00 16 11 09 at 04 00 20 11 09 AT p m 11 00AM 32 PGI MM PMSSY 09 10 N B 43 Paediatric Resuscitation 1000 00 16 11 09 at 04 00 20 11 09 AT p m 11 00AM 33 PGI MM PMSSY 09 10 N B 44 Oxygen Hood 1000 00 16 11 09 at 04 00 20 11 09 AT p m 11 00AM 34 PGI MM PMSSY 09 10 N B 45 Portable ECG Mchine 1000 00 16 11 09 at 04 00 20 11 09 AT p m 11 00AM 35 PGI MM PMSSY 09 10 N B 46 Infant Transport Trolley 1000 00 16 11 09 at 04 00 20 11 09 AT p m 11 00AM 36 PGI MM PMSSY 09 10 N B 47 Table Top Autoclave for O T 2500 00 16 11 09 at 04 00 20 11 09 AT p m 11 00AM 37 PGI MM PMSSY 09 10 N B 48 Fluid Incubator for Warming Fluid in O T 1500 00 16 11 09 at 04 00 20 11 09 AT p m 11 00AM 38 PGI MM PMSSY 09 10 N B 49 Phototherapy Unit 1000 00 16 11 09 at 04 00 20 11 09 AT p m 11 00AM 39 PGI MM PMSSY 09 10 N B 50 Ultrasound Machine for Intra operative 12500 00 16 1
3. MICRO MOSQUITO FORCEPS STRAIGHT 1X2 T KOCHER FORCEPS STR 1X2 TEETH 140MM PEAN ARTERY FORCEPS STRAIGHT 140 MM POLYPUS A SPONGE A DRESSING FORC 175MM CZERNY TUMOR FORCEPS 4X4 TEETH 200 MM BABY MIXTER ARTERY FORCEPS 180MM DUROGRIP NEEDLEHOLDER RYDER 135MM DELIC DUROGRIP HALSEY NEEDLE HOLDER 130 MM DUROGRIP CRILE NEEDLE HOLDER 150 MM DUROGRIP HEGAR MA YO NEEDLE HOLDER 185MM LANGENBECK RETRACTOR 28X14MM 210MM LANGENBECK RETRACTOR 40X10MM 210MM LANGENBECK RETRACTOR 63X20MM 210MM VOLKMANN RETRACTOR SEMI SHARP 4 PRONGED VOLKMANN RETRACTOR SEMI SHARP 6 PRONGED SENN MILLER RETRACTOR DOUBLE ENDED WOUND AND TRACHEAL HOOK SHARP 1 TOOTH WOUND AND TRACHEAL HOOK BLUNT I TOOTH DESMARRES LID RETRACTOR DESMARRES LID RETRACTOR FINE SKIN RETRACTOR GILLIES 180MM SMALL FINE SKIN RETRACTOR GILLIES 180MM LARGE VOLKMANN SPOON SHARP SIZE 00 VOLKMANN SPOON SHARP SIZE 1 VOLKMANN SPOON SHARP SIZE 3 STEEL RULER GRAD IN MM A INCHES 300MM PROBE DOUBLE ENDED 145 MM DIAM 1 0MM PROBE DOUBLE ENDED 160MM DIAM 1 5 MM PROBE DOUBLE ENDED 180MM DIAM 2 0 MM INTERIOR BOX FOR BL 930 NEEDLE CASE PERFOR 7 COMP 150X90X10MM LABORATORY DISH 0 16 L LABORATORY DISH 0 4 L KIDNEY TRAY 250 MM MICRO VASCULAR SET Microsurgical instruments specially designed in consideration with the depth of the operating field for free tissue transfer nerve repair The instruments should be balance in d
4. recharging and should last at least for 2 hours when fully charged need to be demonstrated e Transducers e Convex transducer 2 5 MHz for abdominal applications e Broadband curved array transvaginal 5 8 MHz transducer for Obstetrics and Gynaecological applications with biopsy attachment facility e Optional Transducer High Frequency Linear transducer 5 10 MHz for Vascular Imaging musculoskeletal breast small parts Higher frequency will be preferred with biopsy attachment e Attach list of installations of the same model in India and also provide performance certificates IV The unit and transducers should be covered with comprehensive onsite warranty for five years commencing from the date of issue of installation certificate PGI MM PMS SY 09 10 C 1 114 PGI MM PMS SY 09 10 N B 107 Specification for Biological safety cabinet Class suitable for use in safety categories 1 through 3 Aerosol tight front window of laminated safety glass HEPA filters for supply and exhaust air providing efficiency of 99 999 for 0 3 micron particles Non reflecting lacquer coated rear chamber wall Height not more than 83 when positioned upon accessory stand Audio visual alarm for discrepancies in operating functions Technical Specification Burns Bath Treatment Unit With Lifting System Integrated Burns Bath treatment system with lifting system which eliminates manual transfers and heavy lifting of burn
5. 6 Review software a b 57 09 1 one touch prune trim down EEG video data to specified event with provision to preview the separate date Facility to zoom magnify EEG trace copy or paste EEG or trends to report and presentation Video lock and unlock facility to play audio and EEG data or individually Facility to re size the video display magnify distal zoom the chosen part of video image both during EEG Video recording acquisit ion unit and during analysis on review unit with presentation of resolution of good quality EEG data export facility in EDF format and video data in relevant video files are compatible with window media player Multiple reports customizable in word format View several recordings in cascade window Parallel comparision of window with respect to previous page previous record or any other records Record the EEG on CD amp DVD and review it on any other computer without any additional soft ware Imported trolley for the system 8 Sony RZ 25 digital video camera with as per above mentioned 9 Computer configuration for lab acquisition system a Desktop computer HP OR IBM with minimum core 2 due 2 0 GHz GB DDR2 RAM DVD RW 250 GB HDD licenced window XP b 19 color TEF monitor SONY c Color Laser Printer HP d UPS of suitable rating for 20 30 minis backup PGI MM PM SSY 09 10 N B 98 ClinicalChemicalAutoanalyzer Type discrete fully auto
6. 0 1 C Accuracy of adjustment 0 2 C Option for heated Gel mattress Bedtilt on either sides Integrated X Ray tray Electrical height adjustment with foot switch on either sides The head swivel should be such so as to maintain uniform heading of bed area even in extreme end positions unit should have a CE approval and should confirm to relevant IEC standards PGI MM PMS SY 09 10 N B 105 Transcutaneous Bilirubinometer Specification Screening device that provides a fast on spot objective index of icterus in infants non invasively For Measurement Of Transcutaneous Bill Irubin TcB Measuring range 0 0 mg dIL to 20 mg DI Standard error of estimation based on clinical dara should be proved to have been within 1 mg DI Detectors Silicon photodiodes Hand held 150 200 gms devices for outpatient usage Pocket size Should have internal rechargeable battery lasting 300 400 Measurements on a single charge Preferable should not need any consumables per check In case of consumables requirement consumables for 2 yrs 1000 checks should be included System to conform to standards o CE MDD Directives IEC o FDA PGI MM PMS SY 09 10 N B 103 Incubator Transport Specification Integrated incubator ventilator suction and gas supply with space provision for mounting syringe pumps patient monitoring amp other accessories The complete unit should be moun
7. SANJAY GANDHI POST GRADUATE INSTITUTE OF MEDICAL SCIENCES RAEBARELY ROAD LUCKNOW 226 014 20 21 22 23 24 25 26 2T 28 29 30 TENDER DOCUMENTS GENERAL TERMS amp CONDITIONS FOR NOTICE INVITING Earnest Money be paid in shape of D D TDR FDR drawn in favour of the Director Sanjay Gandhi Postgraduate Institute of Medical Sciences and payable a Lucknow U P India as per mentioned in the tender notification Unless otherwise specified in the order the order price shall remain firm and will not be subject to escalation of any description during the pendency of the order notwithstanding the change in the cost of materials labour and or variations in taxes duties and other levies on raw materials and components may take place while the order is under execution even if the execution of the order is delayed beyond the completion date specified in the order for any reason whatsoever For indigenous goods the price should be on F O R SGPGIMS basis inclusive of all levies and duties wherever applicable which should be indicated clearly The rates of sales tax should be clearly indicated wherever chargeable The SGPGIMS is not eligible to issue C or D Form however the concessional rate of Central Sales Tax admissible to Research Institutions on purchase of Scientific Instruments Equipments etc from certain States like Maharashtra Delhi West Bengal etc is applicable to this Institute Prices wil be quote
8. Adjustable heights suits different heights of beds Overhead dazzle free observation light Built in IV stand Working temperature range 25 degree C to 40 degree C Accuracy of display 0 2 degree C Heating element Quartz encapsulated heater with parabolic reflectors Bright numerical LED temperature display All standard alarm systems high low temp temperature probe failure heater failure system failure PGI MM PM SSY 09 10 N B 33 Pediatric Operating table Specifications Dimensions Length 60 inch Width 16 inch Min Height 30 inch Max Height 40in Electro hydraulically operated Full length x ray translucent top and x ray cassette tunnel Slidable table top towards head end and legend to facilitate unequalled access for C arm image intensifier Anti static mattress and castor wheels with locks Operating positions height adjustment Tredelenburg lateral tilt reverse Tredelenburg kidney elevation Removable head and leg sections Attachments for lithotomy position for small children and infants Removable and folding arm position supports Side bars for fixing other attachments like Mayo table and anaesthesia screen Separate accessory fixing clamps of sliding nature on the side bars both circular socket clamp and circular rotary clamp Stainless steel base and columns PGI MM PM SSY 09 10 N B 34 Portable procedure light Specification Mobile lights on Castors Fo
9. Forceps 12cm long flat handle 9mm wide Forceps 13 5 cm long flat handle 9mm wide st Forceps 18cm long flat handle 9mm wide st balance Forceps 18cm long round handle 8mm dia st Clamp applying forceps for vessel 0 4 to 2 25 Clamp applying forceps for vessel 1 5 to 5 0mm Dissecting Scissors 18cm long round blade handle 10mm dia 10mm long cvd Dissecting Scissors 15cm long round blade handle 8mm dia blade 9mm long cvd Dissecting Scissors 12cm long round handle 7mm dia blade 8mm Adventita Scissors 15cm long round handle 8mm dia blade 9mm long St Adventitia scissors 15cm long round handle 8mm dia blade 7mm long vanas pattern Needle Holder 14cm long Flat handle 8mm wide Needle Holder 12cm long round handle 7mm dia Needle Holder 13cm long round handle 8mm dia Needle holder 18cm long round handle 8mm dia Needle Holder Forceps 15cm long round handle 8mm dia Vessel dialator balance 11cm long flate handle 9mm wide angulated 10 dig Tip dia 0 2mm Vessel dilator 15cm long round handle 8mm dia st Arteriotomy Clamp set of 3 Instrument beaker with silicone bottom Instrument rack for 8 instruments 9 15cm with Clamp box Instrument case 13x23x5cm for 16 instrument Nerve approximator B 1V Microvascular Single clamp8mm for Veins B 2V Microvascular Single clamp11mm for Veins B 3V Microvascular Single clamp17mm for Veins HD S For vessel size 1 5 to 3 5mm Approximator ABB IIV Double approximator without frame
10. Joint Director MM For Director Sanjay Gandhi Postgraduate Institute of Medical Sciences Raebareli Road Lucknow
11. Luggage trolley tuber fame work of MS pipe duly painted to casters heavy duty on bearing with collapsible flaps PGI MM PM SSY 09 10 C 1 56 Alignment software for sequencer Specification Sequencing analysis software ver 3 7 MAC OS to window NT OS Upgrade The important features of this software are as follows Basecalling Factura software based feature assignments Date filtering Sequence assembly Sequence alignment Sequence comparison Report generation PGI MM PMS SY 09 10 N B 109 Laparoscopic Equipments 1 Optic Chain Camera High definition 3 chip camera Medical grade digital 3 chip camera Horizontal resolution gt 1100 lines SXGA technology 1280 X 1024 3 93 million pixels Progressive scan technology not interlaced In built 16 steps digital enhancer 1 3 interline transfer Hyper HAD CCD Electronically controlled digital zoom Remote control on camera head to control four step gain zoom amp white balance controls Graphic disply of activated functions Automatic brightness control Multiple pure digital output Signal to noise ratio of 70 dB Electronic flexible scopes filer to adapt with flexible scopes Standard aspect ratio of 4 3 Brightness image sharpness colour balancing automatically adjusted to attain the best possible picture for the selected speciaility Light Source Xenon light source Fully automatic 300 watt Jaw mechanism for fixing the Fiberoptic cable M
12. RHINOPLASTY COTTLE SCALPEL HANDLE NO 3 COTTLE SEPTUM KNIFE 140 MM MASING CARVING KNIFE 130MM SCISSORS COTTLE SHARP CVD 105MM COTTLE NASAL SCISSOR 105MM CURVED FOMON NASAL SCISSORS 135MM DORSAL SCISSOR COTTLE ANGULAR 165MM GRAEFE IRIS SCISSORS ANGL ON FLAT 100MM JOSEPH SCISSORS FOR RHINOPLASTIC 150 MM COTTLE COLUMELLA FORCEPS 100 MM COTTLE NASAL FORCEPS 145 MM ADSON BROWN ATRAUMATIC FORCEPS 120 MM GRUENWALD FORCEPS BAYON SHAPE 8 DUROGRIP NEEDLEHOLDER CONVERSE 130 MM NEEDLE HOLDER SENNING 170 MM LATHBURY FARRELL COTTON CAR 160MM 1 2MM ALAE PROTECTOR COTTLE KNIFE GUIDE AND RETRACTOR RETRACTOR COTTLE S SHARP 5 1 4 ZOLL COTTLE SKIN HOOK CURVED 180 DEGR FOMON NOSTRIL ELEVATOR 145 MM HOOK COTTLE RIGHT TIP HOOK COTTLE LEFT TIP AUFRICHT NASAL SPECULUM 160 MM NASAL SPECULUM COTTLE SI 2 NASAL SPECULUM COTTLE SI 4 COTTLE NASAL SPECULUM DETACHABLE COTTLE NASAL SPECULUM DETACHABLE SEPTUM CHISEL COTTLE 4MM BROAD SEPTUM CHISEL COTTLE 7 MM BROAD SEPTUM CHISEL COTTLE 9 MM BROAD SEPTUM CHISEL COTTLE 12 MM BROAD SEPTUM CHISEL COTTLE CURVED 6MM GOUGE FOR LATERAL OSTEOTOMY LEFT GOUGE FOR LATERAL OSTEOTOMY RIGHT OSTEOTOMY CHISEL STRAIGHT HAMMER COTTLE COTTLE SEPTUM ELEVATOR COTTLE DOUBLE ELEVATOR MCKENTY RASPATORY SHARP 150 MM JOSEPH RASPATORY SHARP 160 MM SUCTION RASPATORY W MANDRIN 4 MM FERGUSSON SUCT CANN D 2 5MM WORK L 1 10MM FERGUSSON SUCT CANN D 3 0MM WORK L 1 10MM DOUBLE
13. connection to individual monitors to be provided by the supplier Optional accessories printer and twins monitoring probe PGI MM PM SSY 09 Portable Fetal Doppler FOETAL HEART MONITOR PORTABLE To monitor the fetal heart rate 10 N B 18 It should have audio output and can be connected with earphone or recorder with audio input Three heart rate processing modes real time FHR display mode averaged FHR display mode and manual mode with auto and manual counting facility Accurate FHR detection and LCD display Measuring Range 50 240BPM BPM beat per minute with Resolution I BPM and Accuracy 2BPM It should have Power supply battery and battery energy indicator Nominal Frequency of probe 2 0MHz Working Frequency 2 0MHz 10 PGI MM PM SSY 09 10 N B 19 IVF Lab Equipment IVF equipments should be compatible to each other and preferable from the same source in order to make the complete Lab dedicated to one firm This is being suggested in the wake that the after sale service and upkeep of the equipment is done by one company Sr No Equipments Required amp Specifications Qty ANDROLOGY LAB INSTRUMENTS 1 Binocular Microscope I No With Focusing by Co axial Coarse amp Fine focusing controls Halogen Light 6V 20W Objectives 4x 10x 20x amp 40x Eyepiece Compensating Widefield Paired Eyepiece WF10x 2 Makler Sperm Counting Chamber for accurate method of 1 No Sperm Co
14. length 24 30 cm autoclavable fibre optic light transmission incorporated Forward oblique telescope 30 degree enlarged view diameter 5 mm length 24 30 cm autoclavable fibre optic light transmission incorporated Straight forward telescope 0 degree diameter 10mm length 30 31 cms autoclavable fibre optic light transmission incorporated Forward oblique telescope 30 degree diameter 10 mm length 30 31 cm autoclavable fibre optic light transmission incorporated 5 Handinstruments Veress needle with spring mounted blunt inner cannula luer lock length 10 cms Trocar Diameter 3 9 mm working length 5 cms pyramidal tip silicone leaflet valve LUER Lock connector For use with instrument size 3 3 5 Trocar Diameter 3 9 mm working length 7 5 cms pyramidal tip silicone leaflet valve LUER Lock connector For use with instrument size 3 3 5 Trocar Diameter 6 mm working length 5 0 cm Pyramidal tip Silicone leaflet valve LUER Lock connector For use with instruments size 5 mm Trocar Diameter 5 5 6 mm working length 8 5 10 cm Pyramidal tip Silicone leaflet valve LUER Lock connector For use with instruments size 5 mm Trocar Diameter 10 11mm pyramidal tip working length 8 5 10 cms for use with telescope size 10mm Reduction sleeve 11 5 Reduction sleeve reusable instrument size 3 mm trocar canula size 6 mm Scissors rotating diameter 3 mm curved double action jaws connecting pin for unipolar coagulation Met
15. spares and consumables 4 1 System as specified Essential accessories to be included with the unit One set of maintenance spares for the unit to be provided list to be enclosed a Beam blocking tray accessories b UPS Online full load UPS with 20 minutes back up includes x ray for whole unit including accessories should be included c Lead Glass 200 cm X 150 cm or more with lead equivalent to meet the AERB s radiation safety requirements d Immobilization system One complete set of imported patient immobilization accessories of Med Tec head neck thorax and pelvis to be supplied compatible and indexable with the Linear Accelerator table top Med Tec 4 2 4 3 For head and neck U frame S type head extension set of Timo and Silverman neck rest Prone headrest with base plate prone pillow For thorax Extended Wing board Carbon fiber breast board For pelvis Vac Lok 6 nos with vacuum pump Knee and ankle support Others Table index bars of Minimum 2 Nos bolus of 1cm thickness 10 nos Prone pillow Other Accessories a Four lasers LAP green to be quoted one ceiling mounted two lasers mounted on the sidewalls and one more laser facing the gantry mounted on the wall b Additional to the anti collision software mechanical touch guards for the collimator imager amp couch etc to be provided to ensure complete patient safety c Provision for film Cassette Holder of size 35 x 43cm Option of
16. 00AM 16 PGI MM PMSSY 09 10 N B 26 Surgical Instruments For Paediatric Surgery 25 000 00 16 11 09 at 04 00 18 11 09 at Superspecialties p m 11 00AM 17 PGI MM PMSSY 09 10 N B Paediatric Thermal Blanket Patient 2000 00 16 11 09 at 04 00 18 11 09 at 28 Warming System p m 11 00AM 18 PGI MM PMSSY 09 10 N B 29 Paediatric Thermal Mattress 1000 00 16 11 09 at 04 00 18 11 09 at p m 11 00AM 19 PGI MM PMSSY 09 10 N B 30 Neonatal Intensive Care Incubator 2500 00 16 11 09 at 04 00 18 11 09 at p m 11 00AM 20 PGI MM PMSSY 09 10 N B 31 Neonatal Transport Incubator 2500 00 16 11 09 at 04 00 20 11 09 AT p m 11 00AM 21 PGI MM PMSSY 09 10 N B 32 Mobile Neonatal Radiant Heater on a stand 1500 00 16 11 09 at 04 00 20 11 09 AT p m 11 00AM 22 PGI MM PMSSY 09 10 N B 33 Paediatric Operating Table 2500 00 16 11 09 at 04 00 20 11 09 AT p m 11 00AM 23 PGI MM PMSSY 09 10 N B 34 Portable Procedure Light 1000 00 16 11 09 at 04 00 20 11 09 AT p m 11 00AM 24 PGI MM PMSSY 09 10 N B 35 Portable Electrical Slow Suction Machine 1000 00 16 11 09 at 04 00 20 11 09 AT p m 11 00AM 25 PGI MM PMSSY 09 10 N B 36 Paediatric Laproscopy Set 17500 00 16 11 09 at 04 00 20 11 09 AT p m 11 00AM 26 PGI MM PMSSY 09 10 N B 37 Paediatric Cystoscope amp Resectoscope 5000 00 16 11 09 at 04 00 20 11 09 AT p m 11 00AM
17. 23 11 09 AT p m 11 00AM 53 PGI MM PMSSY 09 10 N B 64 Tourniquet Set 2500 00 16 11 09 at 04 00 23 11 09 AT p m 11 00AM 54 PGI MM PMSSY 09 10 N B 65 Magnifying Loupe 2500 00 16 11 09 at 04 00 23 11 09 AT p m 11 00AM 55 PGI MM PMSSY 09 10 N B 66 Power Assisted Liposuction Set 6000 00 16 11 09 at 04 00 23 11 09 AT p m 11 00AM 56 PGI MM PMSSY 09 10 N B 67 Dressing Set for Ward 1000 00 16 11 09 at 04 00 23 11 09 AT p m 11 00AM ST PGI MM PMSSY 09 10 N B 68 Power Drill For Maxillofacial And Small Bone 5000 00 16 11 09 at 04 00 23 11 09 AT Surgery p m 11 00AM 58 PGI MM PMSSY 09 10 N B 69 Titanium Osteosynthesis Plating System 7500 00 16 11 09 at 04 00 23 11 09 AT p m 11 00AM 59 PGI MM PMSSY 09 10 N B 70 Dermabrader Set 2500 00 16 11 09 at 04 00 23 11 09 AT p m 11 00AM 60 PGI MM PMSSY 09 10 N B 7 I Electric Dermatome 2000 00 16 11 09 at 04 00 23 11 09 AT p m 11 00AM 61 PGI MM PMSSY 09 10 N B 72 Skin Graft Mesher 3000 00 16 11 09 at 04 00 23 11 09 AT p m 11 00AM 62 PGI MM PMSSY 09 10 N B 73 Wash Trolley Burn Shower Trolly 1500 00 16 11 09 at 04 00 23 11 09 AT p m 11 00AM 63 PGI MM PMSSY 09 10 N B 74 Basic Plastic Surgery Set Basic Instrument Set 5000 00 16 11 09 at 04 00 23 11 09 AT p m 11 00AM 64 PGI MM PMSSY 09 10 N B 75 Hand Held Dermatome 2000 00 16 11 09 at 04 00 23 11 09 AT
18. 4 6mm Optional Accessories Auto sampler with direct injection method with 200 numbers 1 5ml vials and optional feasibility for 3 or more 384 micro plates to allow measurement of 1152 samples PGI MM PM SSY 09 10 N B 96 Gel Electrophoresis system Horizontal Easy amp convenient to use Various selections of trays and combs UV Transparent acrylic material for real time monitoring of sample migration Uni directional pegs for easy lid removal safety and orientation Removable L form electrode platinum wire kit Tape free casting Dams claw for fitting different length of tray Ability to cast gel in advance while the tank is in use Fixed electric cable attached to safety lid enforce correct operation of with lid and for protection of operator Injection mold design CE certified ISO certified manufacturer Tray size of 15x15cm or 15x10cm or 15x7 cm Comb of 15 or 20 wells and thickness of combs 0 75 1 0 1 5mm Run unto 40 samples at once Buffer volume 650 to 1000 ml Should supplied with Suitable Power unit with following technical specification Compact space saving stackable light weight and user friendly design Should have at least four output terminals to meet versatile requirements Real time display of running conditions including voltage current and time Easy touch panel for all condition setting Adjustable setting while running Audiovisual alarm Status Alarm Automatic recovery after power failure Voltage Range 10 3
19. 4d fetal echo facility both with color and power doppler imaging e Essential requirement a The machine should be supplied with a high resolution B amp W thermal printer It should be possibl print Images from the ultrasound machine console b Trolley The machine and the printer should be mounted on a trolley with lockable castor wheels c Suitable online UPS for the equipment with 30 minutes back up h High resolution photo quality Color Printer for providing printed reports and colour Doppler images to patients 2D ULTRASOUND WITH DOPPLER FOR OBSTETRICS USE IN MATERNAL AND REPRODUCTIVE HEALTH Essential features minimum specifications General e to a The system should have full digital truscan technology b It should be upgradeable for any future applications c It should be suitable for obstetrics and gynecology System operating modes The system should be capable of operating following modes B mode b M mode including M Colour c Pulsed wave Doppler including HPRF mode d Color Doppler e Power Doppler f Tissue Harmonic imaging g Contrast Harmonic Imaging h Compound imaging with at least Nine Lines of sight Display Monitor a 15 inch or larger high resolution non interlaced flat screen monitor CRT TFT liable with tilt and b It should be adjustable with tilt and swivel facility Provision to adjust height should be there Imaging Formats a Convex and micro co
20. 8mm for Veins ABB 22V Double approximator without frame 11mm for Veins ABB 33V Double approximator without frame 17mm for Veins HD D For vessel size 1 5 to 3 5mm approximator CAT NO 03179 10 0 TAPER POINT 100 MICRON NYLON BLACK 4MM CIRCLE 3 8 BOX OF 12 03180 9 0 TAPER POINT 100 MICRON NYLON BLACK LENGTH 15CM CHORD 4MM CIRCLE 3 8 BOX OF 12 03188 9 0 TAPER POINT 140 MICRON NYLON BLACK LENGTH 15CM CHORD 4MM CIRCLE 3 8 ARCH 5MM BOX OF 12 03186 8 0 TAPER POINT NYLON BLACK LENGTH 15CM MICRON 140 CHORD 3MM CIRCLE 3 8 ARCH 3 8MM BOX OF 12 PGI MM PM SSY 09 10 N B 64 PGI MM PM SSY 09 10 N B 65 PGI MM PM SSY 09 10 N B 66 TOURNIQUET SET Specifications e Tourniquet should be an automatic one Whth instant increase in pressure auto regulator to control pressure in the cuff automatic time setting with auto alarm e Should have battery back up system automatically engaged if AC current is interrupted Should have computerized memory e Should have microprocessor monitors and gives alarm both by audible amp visual indicators e Should have alarm for Low pressure Low battery Leaks Kinks elapsed time and start up checks e Should be able to operate either as single or double cuff IVRA function e Should be provided with autoclavable tourniquet cuffs with silicone bladder Single and double for baby child amp adult for arm amp thigh Specification for Magni
21. ENDED FILE FOMON 210MMLONG DOUBLE ENDED RASP FOMON 210MMLONG JOSEPH NASAL SAW CURVED TO RIGHT 170MM JOSEPH NASAL SAW CURVED TO LEFT 170 MM BONE AND CARTILAGE CRUSHER W METAL CLAMP WEIL BLAKESLEY ETHMOID FORCEPS 4 2MM WATSON WILLIAMS ETHMOID FORCEPS TOOTHED COTTLE WALSHAM SEPTUM STRAIGHTENING FORC BONE CUTTING FORCEPS FINE 170 MM JANSEN MIDDLETON NASAL COTT FORC 210MM 9 MASTOPLASTY Breast Surgery SET MAIER POLYPUS FORCEPS WITH RATCHET CVD BACKHAUS TOWEL HOLDING FORCEPS 110MM TOWEL CLAMP 115 MM LENGTH SCALPEL HANDLE NO 4 SCALPEL HANDLE NO 3 DISSECT SCISS METZENBAUM 145MM CVD DURO DISSECT SCISS METZENBAUM 180 CVD DUROTP DUROTIP DISS SCISS METZENBAUM CVD 200MM DUROTIP LIGATURE SCISSORS 180MM LONG DUROTIP DISS SCISS MAYO LEXER CVD 165MM OP SCISSORS STR BL SH 145 MM S DISSECTING FORCEPS SLEND PATT 145 MM TISSUE FORCEPS AM PATT 1X2 T 145MM TISSUE FORCEPS 1X2 T 200MM MEDIUM SIZE ADSON BROWN ATRAUMATIC FORCEPS 120 MM FORCEPS STRAIGHT 2MM JAW ATRAUM 150MM FORCEPS STRAIGHT 2MM JAW ATRAUM 200MM HALSTED MOSQUITO FORCEPS CURVED 125MM HALSTED FORCEPS CURVED 1X2 TEETH 125MM KOCHER FORCEPS STR 1X2 TEETH 140MM ROCHESTER PEAN ARTERY FORCEPS STR 160MM GROSS POLYPUS SPONGE AND DRESS FORCEPS OVERHOLT DISSECTING FORCEPS FIG 1 209MM OVERHOLT DISSECTING FORCEPS FIG 2 220MM CZERNY TUMOR FORCEPS 4X4 TEETH 200 MM LANGENBECK RETRACTOR 40X10MM 210MM KOCHER LANGENBECK RETRACTOR 80X16 MM HABERE
22. FITTINGS FOR MECHANICAL AIR REMOVAL LE VACUUM PRE VACUUM AND DRYING POST VACUUM 2 NOISE CONTROL ANTI VIBRATION MOUNTING 3 ALL PIPES FITTING STAINLESS STEEL OF GRADE X 4 CR 19 NI9 CONNECTION amp STAND ISS 304 SI oF IS 6911 4 STEAM GENERATOR S S STEAM GENERATOR WITH AUTOMATIC PRESSURE REGULATION amp OVER PRESSURE SAFETY amp MEETING ALL NECESSARY REQUIREMENTS 5 PLUG SCREEN ONE REMOVABLE PLUG SCREEN FOR CHAMBER DRAIN LINE TO BE PROVIDED PGI MM PM SSY 09 10 N B 26 6 BAFFLE S S BAFFLE PLATE FOR EVEN DISTRIBUTION OF STEAM TO BE PROVIDED E TERMS AND CONDITIONS 1 INSTALLATION ON TURNKEY BASIS I E ONLY WATER ELECTRIC AND STEAM SOURCE AT SITE WILL BE PROVIDED ALL CONTROL LIKE ICPT SWITCH INPUT VALVES AND PRV IF REQUIRED SHOULD BE PROVIDED INSTALLED BY THE SUPPLIER 2 ISI CERTIFICATE AND LIST OF USERS INSTALLATIONS OF RECTANGULAR STERILIZER MAY BE PROVIDED 3 THE SUPPLIER WILL PROVIDE 2 SETS OF OPERATING MANUAL AND CIRCUIT DIAGRAM AND A SERVICE MANUAL 4 GUARANTEE WARRANTY OF 05 YEARS 5 OFFER FOR BOTH COMPREHENSIVE LABONR amp SPARE MAINTENANCE AND NON COMPREHENSIVE ONLY LABOUR AND PRICE LIST OF SPARE PART WITH VALIDITY OF RATES TO BE PROVIDED 6 95 UPTIME DURING WARRANTY AS WELL AS DURING MAINTENANCE CONTRACT FINE PENALTY AS PER INSTITUTE TERMS 7 COPY OF CERTIFICATE FROM BIS SHOULD BE ATTACHED ALL TESTING CERTIFICATES F
23. Fr length 30 cms double action jaws 3 Biopsy forceps double action jaws 5 Fr Length 30 cms 4 Coagulating electrode 3fr unipolar length 53 cms 5 Deflux needle with obturator 6 Camera monitor light source as specified in the laparoscopy set the same would be used for cystoscopy PGI MM PM SSY 09 10 N B 38 Pediatric bronchoscopy set Specification 1 D Rigid ventilating bronchoscopes Bronchoscope size 2 5 or 2 8mm diameter Bronchoscope size 3 Bronchoscope size 3 5 or 3 7 mm diameter Bronchoscope size 4 or 4 7 mm diameter Bronchoscope size 5 or 5 2 mm diameter Bronchoscope size 6 or 6 2 mm diameter Prismatic light deflector autoclavable with connection for fibreoptic cable Telescopes Straight forward telescope 0 degree diameter 2 7 mm 2 9 mm autoclavable fibreoptic light transmission incorporated Forward oblique telescope 30 degree diameter 2 7 mm 2 9 mm autoclavable fibreoptic light transmission incorporated Straight forward telescope 0 degree diameter 3 4 mm autoclavable fibreoptic light transmission incorporated Forward oblique telescope 30 degree diameter 3 4 mm Straight forward telescope 0 degree diameter 4 0 mm Forward oblique telescope 30 degree diameter 4 0 mm Optical alligator forceps for pediatric bronchoscope for removal of hard foreign bodies Optical forceps for pediatric bronchoscopes for removal of peanuts and soft foreign bodies Optical forcep
24. Guarantee Warrantee period The warrantee period will be extended for the period of the Instruments remain out of order during warrantee period The tenderer shall also confirm the Installation Commissioning Demonstration and Training to the concerned of this Institute The tenderer shall submit the pre requisite information like Civil works Electrical details etc within 2 weeks from the date of receipt of order or establishment of letter of credit as the case may be The Institute reserves the right to cancel reject in full or any part of the tender which generally do not fulfill the conditions stipulated in the tender without assigning any reason Any action on the part of the tender to influence any body of the Institute will make his their tender liable to rejection The tenderers shall submit the offer with in original copy of the tender documents duly signed on each page Item wise rates indicating units can be offered on letter head of the firm In the case of placement of Purchase Order the vendor the tenderers whose tender is accepted shall have to confirm the purchase order within 7 days from the date of the dispatch of purchase order otherwise it will be deemed that offer is acceptable to the firm Notwithstanding any other provision the terms amp conditions and any other items given in the Purchase order will be treated as binding with Errors amp omission Expected basis However if the supplier notices any mistake in the contentions
25. Health 10000 00 16 11 09 at 04 00 28 11 09 AT p m 11 00AM 128 PGI MM PMSSY 09 10 N B 110 Ultrasoniccutting amp Coagulating Deviceforopen 12500 00 16 11 09 at 04 00 28 11 09 AT And Laparoscopic Surgery Scalpel p m 11 00AM 129 PGI MM PMSSY 09 10 N B I 1 1 Hysteroscopy Equipment 5000 00 16 11 09 at 04 00 28 11 09 AT p m 11 00AM 130 PGI MM OT 15 09 10 Patient positioning appliances 6000 00 16 11 09 at 04 00 28 11 09 AT p m 11 00AM 131 PGI MM PMSSY 09 10 N B 112 Bilevel positive pressure 1000 00 16 11 09 at 04 00 28 11 09 AT ventilators BiPAP pm id 132 PGI MM PMSSY 09 10 N B 113 Portable Color Doppler Ultrasound 10000 00 16 11 09 at 04 00 28 11 09 AT p m 11 00AM The Tender documents may be downloaded from our website www sgpgi ac in Tender documents duly filled in will be received by speed post Regd Post Courier only in the RSD Cell 3 Floor Administrative Block of the Institute in two bid system i e technical bid amp price bid in separate envelop Both envelop may be sealed in single envelop The tender no and the name of item must be super scribed on the top of the envelop The tender fee for Rs 300 00 Rs Three hundred only Non Refundable along with Earnest Money Deposit Refundable for respective tenders as indicated against each tender may be enclosed separately with tender documents in the shape of demand draft Nationalized Bank only payable at Lucknow in favour of the Direc
26. WORKING PRESSURE e DOOR SINGLE RADIAL ARM e CARRIAGE NO EACH THE STERILIZERS SHOULD BE CONFIRMING TO IS 3829 WITH ISI MARK VALID CERTIFICATE FROM ISI SUITABLE FOR STERILIZATION OF WRAPPED AND UNWRAPPED S S INSTRUMENTS amp OTHER DEVICES LINEN GLASSWARE RUBBER GOODS amp LIQUID IN OPEN BOTTLES AND CAN BE OPERATED ON BOTH STEAM FROM CENTRAL STEAM FACILITY AND INBUILT STEAM GENERATOR A MATERIAL OF CONSTRUCTION 1 CHAMBER STAINLESS STEEL OF 316 OF IS 6911 OF 1992 1 JACKET CARBON STEEL B O D iii DOOR STAIN LESS STEEL OF 304 OF IS 6911 OF 1992 iv DOOR GASKET HIGH TEMPERATURE RESISTANT SILICONE ELASTOMER TYPE SUITED FOR AUTOCLAVING OPERATION MATERIAL SHOULD BE NON TOXIC AND COMPLIES WITH THE REGULATIONS FOR AUTOCLAVING USE v INSULATION NON FIBER SHREDDING RESIN BONDED GLASS WOOL WITH S S COVERING OF 304 or IS 6911 or 1992 vi DOOR HINGED TYPE WITH RADIAL ARMS WITH PROCESS LOCK TO PREVENT OPENING OF DOOR DURING THE PROCESS AND DOOR OBSTRUCTION SAFETY TO PREVENT CLOSING OF DOOR IN CASE OF AN OBSTRUCTION vii MOUNTING ON STAINLESS STEEL TUBULAR STAND WITH LEVELING LUGS OF 6 vili VACUUM SYSTEM WATER RING TYPE VACUUM PUMP THE SHELL AND TUBE TYPE CONDENSER SHOULD BE FABRICATED FROM STAINLESS STEEL OF 304 1 STEAM SUPPLY THE STEAM GENERATOR SHOULD HAVE HEATERS OF REQUIRED ELECTRICAL LOAD AUTOMATIC PRESSURE CONTROLLER WITH GAUGE LOW WATER LEVEL CUT OFF SAFETY VAL
27. a large imagine space and C Arm clearance around the patient and the imaging table The C Arm should have a manual rotation of 180 to allow the imaging chain to accomplish angled projections The C Arm should have orbital movement of 90 45 for better penetration in Cranio Caudal movement The system should have at least 45 cm of motorized vertical C Arm travel capability to adjust the imaging chain height The C Arm should provide side to side wig wag and the horizontal travel movement to allow panning during imaging Generator amp X Ray Tube The Generator should be Micro Processor controlled converter type output of 15 KW or more and minimum 75 kHz frequency or Higher The system should operate in full capacity on 220 volts AC 15 Amps Fluoroscopic kVp range 40 120 kVp or more Fluoroscopic mA range 0 10 8 8 mA or more Radiographic kVp range 40 110 kVp or more Radiographic mA range minimum 60mA The generator should be capable of providing a boost or a high dose fluoroscopic exposure at up to a minimum of 20mA The generator should be capable of providing a boost or a high dose fluoroscopy with pulse rates up to 25 frames sec The tube should have additional safety filtration for the stray or scattered radiation i e cu filters Focal spot size should be 0 3mm amp 0 6 mm dual focal spots Anode cooling capacity should be 300Kh U or higher Anode heat storage capacity should be 70kHU min or higher The tube hous
28. amp Storage Container SSY 09 EE Specification f Double lid system g B Thermoloc sealing of lid self acting by temperature h C Lid stainless steel aluminum base aluminum i Bio Barrier stainless steel valve j Thermostatic condensation drain in the bottom k Two handles one at either end of container with silicone rubber covering 1 Minor variation in size can be considered m The offer should indicate the number of sterilization cycles a container can undergo life n Ifavailable the containers must display the number of time the container has undergone sterilization cycles Sizes 60x30x30 cms p 60x30x15 cms q 30x30x30cms PGI MM PM Electrocautery Argon Plasma coagulator SSY 09 10 C 2 08 Specification Electrsurgery unit with forced APC mode 0 Upgrade ENDO cut V 1 0 Two pedal footswitch AP amp IP X8 Equipment APC 2 Unit for VIO System Argon gas bottle 5 ltrs 200 bar Pressure reducer with sensor Silicon electrode conductive area 17 5x29 5 cm 516 cm suare with rubber strap and ECG connection Patient plate cables international for silicon plate length 4 m Monopolar connecting cable Bovie jack for CUT and COAG MIS instruments length 4 m Connecting cable for flexible APC probes 2 5 m long APC probes 2200 A OD 2 3 MM L 2 2 m APC probes 2200 SC OD 2 3 mm L 2 2 m PGI MM PM SSY 09 10 C 2 09 Endoscope Disinfection System Mixed oxidant solution generator with electrolyte pack
29. arms with large reach of 1 30 m suitable for connection to 230V 50Hz single phase mains supply free float magnetic system release of magnetic brakes by handgrips Liquid crystal display LCD with user prompts quick set up of different parameters and their Activation at press of a button such as automatic speed adjustment or automatic brightness setting depending on magnification brightness of video image magnetic brakes on ff SUPPLEMENTARY EQUIPMENT FOR FACE TO FACE SURGERY Stereo bridge with two additional output ports for connection of co observation device and video Camera 180 degree tiltable binocular tube with focal length of 200 mm pair of high eyepoint push in eyepieces 12 5x with magnetic lock pair of rotable adapters 22 5 degrees DIGITAL VIDEO CAMERA SYSTEM Advanced digital 3CCD video camera system with digital video output suitable for connection to PC color monitor DVD recorder speed focus system Good quality voltage stabilizer 2 set of Ergonomically Designed Chair with adjustable height for surgery PGI MM PM HAND HELD VASCULAR DOPPLER SSY 09 EE 10 N B 61 Specifications The instrument should have LCD display 8 MHz Bi directional doppler probe PPG Photoplethysmograph probe CD software Computer Interface cable and its standard accessories Set of rechargeable batteries with charger Specifications Power DC 94 3 V alkaline tall
30. e mesh the skin graft to expand for coverage of large surface new areas e Mesher should have a full range of meshing ratios with adjustable meshing drum allowing meshing ratios from 1 1 to 4 1 e Should have two sets of oscillating blades rolling over each other e Theoscillating blades should be operated with a hand grip knob for ease of operations e Blades should have piercing function amp not cutting edge to have long life The set of oscillating blades should be mounted on an inclined platform with a front loading amp a rear holding plate The rear holding plate should be detachable for easy maintenance amp cleaning The mesh graft should be loaded without any carrier sheets to prevent recurrent costs Variable Mesher should be able to operate both as powered or manual mesher Should be able to use any sterile smooth plastic of 0 5mm thickness as skin graft carrier Should be simple amp ergonomic design Should be provided with a Sterillizing container b Skin Graft Carrier Power pack including motor gear d Batteries e Ratchet PGI MM PM SSY 09 10 N B 73 Wash Trolley Burn Shower Trolly Specification The shower trolley should have a highy low bath tub Hydraulic power should raise or lower the tub converting it to a tub from a level platform The bottom should be softly padded and covered with thermally insulated vinyle Should have separate hydraulic pedals for raising amp lowering the
31. holding forceps non 18 cms serrated tips non toothed toothed 20 cms 25 cms 13 DeBakey s atraumatic vascular forceps Vascular forceps atraumatic jaws 1 0 mm wide tip 15cm 19 5 cm 24 cm 14 Micro tissue forceps Round handles soft spring tension platform tip straight 15 cms Straight tip 21 cms Straight tip 15 Micro forceps jeweller type 110mm 16 Toothed forceps Medium size Long heavy 17 Thumb forceps long heavy Needle holders 18 Needle holder TC converse 130mm 19 Needle holder Crile Wood Delicate pattern 15 cms 20 Jameson needle holder 23 cms 21 De Bakey s needle holder Tungsten carbide inserts gold plated ring handles slender pattern 18 cms 23 cms 25cms 22 Ryder very delicate suture size 5 0 I mm jaw diamond dust coating tungsten amp smaller carbide inserts on the inside of jaws gold plated ring handles serrated jaws 14 cms 18 cms 22 cms 25 cms 23 Castroviejo needle holder Straight diamond dust coating tungsten carbide inserts on the inside of jaws gold plated ends 14 5 cms 18 0 cms 24 Micro needle holder Round handle straight tip with ratchet diamond dust coating tungsten carbide inserts on the inside of jaws 15cm 18cm 21 cm 25 Needle holder long heavy 20 cms Vascular clamps hemostatic forceps vessel clips 26 Bull dog clamp Dieffenbach Curved 38 mm total length 12 mm length of Jaw serrations 48 mm total length 16 mm length of Jaw serrations 27 Bull dog clamp Diethrich Curved 48 mm total
32. m 11 00AM TT PGI MM PMSSY 09 10 C 2 11 Clinical Scale Magnetic cell Sorter for Isolation 10000 00 16 11 09 at 04 00 25 11 09 AT of CD 34 Stem Cell p m 11 00AM 78 PGI MM PMSSY 09 10 C 1 121 Flexible Ureteroscope 3000 00 16 11 09 at 04 00 25 11 09 AT p m 11 00AM 79 PGI MM PMSSY 09 10 C 2 20 Automated Immunostainer 12500 00 16 11 09 at 04 00 25 11 09 AT p m 11 00AM 80 PGI MM PMSSY 09 10 C 1 130 Flexible Cystoscope 1800 00 16 11 09 at 04 00 25 11 09 AT p m 11 00AM 81 PGI MM PMSSY 09 10 C 1 36 Water Purification System 2500 00 16 11 09 at 04 00 25 11 09 AT p m 11 00AM 82 PGI MM PMSSY 09 10 N B 77 Spectrophotometer 2500 00 16 11 09 at 04 00 25 11 09 AT p m 11 00AM 83 PGI MM PMSSY 09 10 N B 78 Microfuge Centrifuges 1800 00 16 11 09 at 04 00 25 11 09 AT p m 11 00AM 84 PGI MM PMSSY 09 10 N B 79 Table Top Centrifuges 2500 00 16 11 09 at 04 00 25 11 09 AT p m 11 00AM 85 PGI MM PMSSY 09 10 N B 80 Speed Vac Centrifuges 1250 00 16 11 09 at 04 00 25 11 09 AT p m 11 00AM 86 PGI MM PMSSY 09 10 N B 81 Low Speed High Capacity Centrifuges 2500 00 16 11 09 at 04 00 25 11 09 AT p m 11 00AM 87 PGI MM PMSSY 09 10 N B 82 Monopan Balance 1000 00 16 11 09 at 04 00 25 11 09 AT p m 11 00AM 88 PGI MM PMSSY 09 10 N B 83 Refrigerator 3001trs 1000 00 16 11 09 at 04 00 25 11 09 AT p m 11 00AM 89 PGI MM PMSSY 09 10 N B 84 Deep Freezer 2500 00 16 11 09 at 04 00 25 11 09 AT p m 11 00AM 90 PGI MM PMSSY 09 10 N B
33. of 0 5 ml each and with inbuilt dynamic gradient sofrware thermal range 5 105 C temperature variation 1 C across the entire block Ramping speed of 2 degree C per second heated lid simple to program with capacity to hold at least 100 programs each program should allow upto 8 segments Operation on 230 V 50 Hz power supply auto restart option in cased of power failure Optional Features a block to hold 0 2 ml tubes b block to hold 96 well plates Rd Gel Documentation System Specification 10 N B 87 UV and white light transilluminator with CCD camera with UC filter and zooming facility dark room hood and image viewing facility and image acquisition softare should allow integration of image over a variable duration of time Image analysis software with possibility of rotation mirror inversion brightness and contrast alteration identification of bands and lanes calculation of MW and intensity etc Should allow integration of image over a variable duration of time Operation on 230V 50 Hz power supply 2 year warranty 230V AC 50 Hz cycle PGI MM PM SSY 09 10 N B 88 Microwave Oven Specifications Fully automatic with digital time and temperature display Capacity should be 32 Litre Bio ceramic Enamel coated interior Power supply AC line 50 Hz 220 240 volts PGI MM PM SSY 09 10 N B 89 PGI MM PM Ph Meter Specification Should be versatile simple to use pH mV and temperature meter that is ide
34. of a button System should have a maximum depth of 30 cm Dynamic range of 120Db or more 4d Frame rates should be more than 20 frames sec System should have real time zoom and zoom facility on frozen image too System should have a facility for Real time Calculation for Spectral doppler System should have an integrated image management system for printing and storing images for the offline analysis System should have Dicom facility to connect it to the hospital server printer and PACS System should have inbuilt CD DVD drive for copying images directly on CD The system should have direct printing facility on both thermal and color inkjet printer The system should store real time loops in B mode and Color mode System should have the facility for the parallel slicing of the volume in real time mode view possible in Real amp Post with and without color flow as well System should have real time coronal imaging facility possible System should have broad band high frequency tranducers with 5 frequecny selection option Multifrequency convex transducer of 2 5Mhz for obstetrics and gynaecological application Multifrequency Volume transducer from 2 5Mhz for obstretic and abdominal 4d imaging Multifrequency Volume transducer from 5 9 Mhz for transvaginal and transrectal 4d imaging Multifrequency linear tranducer of 5 12 Mhz for small parts and vascular imaging optional e Biopsy Needle guides with kit e System should have advanced
35. of flow cell External inputs for lamp off switching and auto zero Variable signal output for best peak presentation Optics Double beam and ratio mode Calibration Built in Hg lamp Range 190 600 nm Light source Ds lamp Accuracy nm Bandwidth 6 nm Noise lt 0 6x 10 AU Drift 10x 10 AU h AUFS range 0 25 0 5 1 2 AU Response 0 05 0 1 0 5 1 2 4 8s Programs 9 programmable steps Max Steps 100 in 9 programs Available functions Wavelength time auto zero and hold Should have GLP functions Fluorescence detector Should operate at 200 nm to 900 nm Innovative flow cell designed for less dispersion less stray light less volume and more pathlength for maximum sensitivity Three dimensional spectral scanning for faster method development and optimization and enhanced peak identification Single or multi channel operation monitors fluorescence at one or more discrete wavelength pairs Axially illuminated flow cell Allows for better light absorption resulting in highest sensitivity Advanced optical design Maximizes light throughput and reduces light scatter allowing for better signal to noise performance Low noise performance Less stray light due to orthogonal optics and the use of mirrors not lenses minimize scatter Multiple detection modes 2D 3D and on the fly spectral scanning can greatly reduce the time needed to develop fluorescence detection methods by quickly determinin
36. the density of the tissue An electronic zoom function an automatic save function to hard disk Mosaic Display The system should be capable of saving more than 10 000 images to internal hard disk and retrieve stored images later The system should provide digital subtraction and roadmap imaging modes for vascular application upto 25 frames sec with subtraction Road mapping Remasking max Pacification View Trace CO2 imaging smart masking etc 3d Reconstruction Capability The system should be quoted with an additional work station to offer 3D reconstruction by using sequence of 2D images that were acquired with C Arm by using multiplanar reconstruction and using volume rendering The system should give detailed reconstructed volumes provide more information on the anatomy resulting in more precise interventions The system should with a medical DVD recorder to give the images to the patients Remote Control One cordless remote control for image handling functions Essential Accessories Suitable Sevo Voltage Stabilizer should be quoted with the system Table Suitable table for abdominal work shall be quoted preferably imported Should be Dicom compatible PGI MM PM SSY 09 10 N B 112 Bilevel positive pressure ventilators BiPAP a Capability to independently control inspiratory and expiratory pressure levels b Inspiratory pressure range from 3 upto 25cm H20 or better c Expiratory pressure range from 3 upto 25cm H20 or bette
37. to vendors account and included in the warranty and CMC period ELECTRICAL 1 Required capacity of UPS for operating the Simulator along with X ray mode with a minimum 20 minutes backup to be provided 2 Electrical Panel for all the electrical connections with necessary MCBs for the simulator to be provided 3 Necessary Electrical points for the simulator and its accessories and room lighting controlled by the Simulator and Dimmer controlled spot lights to be provided 4 Earthing to be provided from a separate earth pit TABLES 1 Tables in control room with necessary keyboard drawers to be provided 2 Four numbers of computer chairs to be provided 3 Cupboards in simulator room for simulator accessories and in the control room to be provided Two additional full size steel almirahs to be provided 4 Water bath for thermoplastic cast fabrication to be provided 5 View box to see 4 full size X ray films simultaneously 6 Two lead aprons POWER Requirement for the simulator from the institute 1 Hospital will provide 100KVA 3 phase power and terminate in the simulator room S ro wc OED 66 i d CABIN Mould Room c Room o o o o a a o o 9 PGI MM PM Specification for 44 channel digital video EEG system Video Telemetry System SSY 09 10 C 3 09 Digital video EEG system with following feature 2 capability of recording EEG EOG EMG EK
38. treatment of one or two limbs simultaneously It should not require DVT sleeves below cuffs It should delivers constant preset pressure rang 20 80mm of Hg Should be portable electrically operated with good battery backup with universal size of sleeve to cover Calf Thigh amp Foot Standard Accessories should include Connecting tube Universal sleeve for thigh calf amp foot Small Universal sleeve for thigh calf amp foot Medium Universal sleeve for thigh calf amp foot Large PGI MM PM SSY 09 10 N B 71 Electric Dermatome Specification Should be able to cut graft of various width Should be provided with variable Guards to adjust the width of the Graft to 2 3 or 4 Should not need any carrier to lift the Graft from the donor site The cut graft should automatically fold into the pocket of the Dermatome The graft should be server by simply lifting of the Dermatome up amp away from the donor site without a carrier The thickness of the graft should be adjusted with a carrier e Thickness of the graft should be adjustable to thousandths of an inch Should be supplied complete with motor unit in the handle set of guard calibration guide power plug cord screwdriver amp should be supplied complete with a carrying case for proper maintains and 20 blades Should have facility for temporary replacement with same model during repairs PGI MM PM SSY 09 10 N B 72 Skin Graft Mesher
39. unit is in operation Reaction Medium Compact specific reaction plate MTPformat with 96 wells Signal Generation Nitrogen laser emission at 337nm Signal detection 2 photomultipliers Incubation time 9 to 59 minutes test specific Online Connection LIS interface This should be provided with an external PC for data processing and a laser printer and the software for the risk analysis should be provided along with it Suitable online UPS for the equipment with 30 minutes back up should be provided PGI MM PM SSY 09 10 N B 23 Flexible Fetoscopy Equipment Should have minimum diameter of appropriate length and maximum resolution for fetal visualisation and fetal laser surgery in twin to twin transfusion syndrome Specification 1 Telescope Semiflexible 0 fiber optic scope which can be curved with diameter 2mm and length 30cm with remote eye piece and angle of inclination could be 30 or more 2 Fetoscopic sheath with channels for laser fibers upto 600um with one stopcock and one Luer lock adaptor 3 Trocar and cannula Specially developed for amniotic sac 4 Nd YAG laser or Diode laser can be set at 30 70w PGI MM PM SSY 09 10 N B 24 Surgical Instruments For Maternal amp Reproductive Health The exact size of the instrument can vary upto 1096 on either side SI No Name of the item with specification SIMS Bivalve Vaginal Speculum 75x30MM 125MM SIMS Bivalve Vaginal Spe
40. 0 16 L 4 CLEFT LIP SET REPAIR OF HARELIP GROSS POLYPUS SPONGE AND DRESS FORCEPS BACKHAUS TOWEL HOLDING FORCEPS 110MM TOWEL CLAMP 115 MM LENGTH STEVENS TENDON SCISSORS CVD BLUNT I 10MM KILNER DISSECTING SCISSORS 150 MM IRIS AND LIGATURE SCISSORS STR 110 MM OP SCISSORS STR BL SH 145 MM S ADSON FORCEPS FINE SERRATED JAWS 120MM ADSON FORCEPS 1X2 TEETH 120 MM GRAEFE FIXATION FORCEPS 110MM MICRO HALSTED HEMOST FORC CVD 125 MM PEAN ARTERY FORCEPS STRAIGHT 140 MM DUROGRIP HALSEY NEEDLE HOLDER 130 MM JOSEPH HOOK 2 SHARP PRONGS 165MM FERGUSSON SUCT CANN D 2 5MM WORK L 1 10MM LABORATORY DISH 0 16 L 5 CLEFT PALATE SET REPAIR OF CLEFT PALATE BACKHAUS TOWEL HOLDING FORCEPS 110MM TOWEL CLAMP 115 MM LENGTH FRAME ONLY TONGUE SPATULA RUSSEL DAVIS 67X29MM TONGUE SPATULA RUSSEL DAVIS 75X33MM TONGUE SPATULA RUSSEL DAVIS 85X38MM HARTMANN TONGUE DEPRESSOR 150 MM SCALPEL HANDLE NO 7 KILNER DISSECTING SCISSORS 150 MM JOSEPH SCISSORS FOR RHINOPLASTIC 150 MM OP SCISSORS STR BL SH 145 MM S DISSECTING FORCEPS SLEND PATT 145 MM FORCEPS STRAIGHT 2MM JAW ATRAUM 150MM TISSUE FORCEPS AM PATT 1X2 T 145MM MICRO HALSTED HEMOST FORC CVD 125 MM ROCHESTER PEAN ARTERY FORCEPS STR 160MM DUROGRIP CRILE NEEDLE HOLDER 150 MM FINE SKIN RETRACTOR GILLIES 180MM LARGE FREER ELEVATOR SHARP BLUNT 185MM HOWARTH ELEVATOR DOUBLE ENDEN CURVED PALATE RASPATORY CURVED TO LEFT PALATE RASPATORY CURVED T
41. 00V in 1 Volt Steps Current Range 4 500 mA in I mA STEPS 90W MAX Output terminals 4 Set in parallel Operating temp 0 40 CTimer Control 0 999 minutes Display 3 digit 7 segment LED PGI MM PM SSY 09 10 C 1 40 Heavy duty cooking range Heavy Duty single burner LPG cooking range stove size 24 x24 x24 SS body The range will have a burner with burner control valve and a pilot lamp spillage collection tray and adjustable bullet feet for specified food preparation such as preparation of low potassium lentils and vegetable and low fat seasoned lentils and vegetable for individual groups of patients and dietary specification PGI MM PM SSY 09 10 C 1 41 Internal air circulation system Vendors are required to submit their own offer specification which will be decided on the basis of technical specification and demonstration The vendors may visit the site on any working day between 10 30 to before submitting their offer PGI MM PM SSY 09 10 C 1 42 Heavy duty mobile storage drum Assorted a Heavy duty plastic food grade storage mobile drum or mobile bins with lid capacity 150kg 100kg 50kg 25kg 10kg These storage drums are required for storage of grocery items and dry ration storage b Heavy duty plastic garbage collection and disposal mobile drum or mobile bins with lids cap 150kg 50kg 25kg 10kg c Waste food mobile drums bins with lids for transportation of waste food The drum bins sho
42. 1 7 W D 30 0MM Plan Achromat 10X N A 0 25 W D 10 5 mm C Mount TV Adapter A SPARES Halogen Lamp 12V 100W LL No No 16 Micromanipulator Mechanical Non Hydraulic System for ICSI and PGD oil free single lever control for all axis Stage including 4 Channel Temperature Controllers Single lever control for XYZ movements Two Additional Metal Heated Stage and extra port for connecting Extra stage warmer Digital Help Menu Pipette Home Function Both side Double Tool Holder 1 Air Syringe 2 Xyz Mechanical Stage 1 Glass Heated Central Stage Insert 16mm Hole 1 17 Laser System for assisted Hatching amp Embryo Biopsy with No Control Box Hand Held control unit Collimator mirror Fiber Optic Cable Pilot Laser Targeting System and Laser Objective to be Mounted On Inverted Microscope with Software for embryo analysis which can stand alone capable of working even without pc Laser power 300 400mw 18 Spindle Ultra Imagining system from Oocyte Imaging System 1 No for Routine Operation For Non invasive Imaging of the Spindle and Zona Pellucida in Living Oocyte with facility of Color Overlay Specifications Optical Wavelength of operation 546nm prefereable Good Spatial Resolution with Limited Diffraction Relay Optics 0 65x requires 1x c mount attachment Electrical Controls Power Source Universal Serial Bus 2 0 USB 2 0 to CPU Image Acquisti
43. 1 Endoscope washer system 2 Ethylene oxide sterilizer with vacuum chamber 1 Air purification system for at least 4 000 cu ft air 3 Hand sanitizers with solution 5 Detailed specification are mentioned below 1 Specifications for mixed oxidant solution generator e Mixed oxidant solution generation system for on site generation of non toxic biocidal agent should have capacity to produce 800 L of mixed oxidant solution per day a concentration of more than 400 ppm e Solution should be generated at low current of lt 10 amp e Mineralization of the generated solution should not exceed 5 liter and ph should be almost neutral e Power consumption should not be more than 350 watts e Electrolyte Pack for item 1 Concentrated electrolyte pack for the mixed oxidants solution generator 2 Specifications for Endoscope Washer Fully automated endoscope washer for fully immersible endoscopes Programmable cycles for disinfection water rinsing and air drying programs and with timers Proper alarm system for any blockages endoscope channels Self cleaning and sterilization option Full set of accessories needed for system 3 Specifications for Ethylene Oxide sterilizing unit e ETO sterilizing unit with inbuilt vacuum and aeration chamber and with a capacity of approximately 50 60 liters Fully automated and programmable cycles for disinfection and aeration ETO leakage warning alarms desirable 4 Specifications for Air Purificati
44. 1 09 at 04 00 20 11 09 AT Ultrasound p m 11 00AM 40 PGI MM PMSSY 09 10 N B 51 Choledoscope 3500 00 16 11 09 at 04 00 21 11 09 AT p m 11 00 AM 41 PGI MM PMSSY 09 10 N B 52 Air Mattress for Bedsore Prevention 1000 00 16 11 09 at 04 00 21 11 09 AT p m 11 00 AM 42 PGI MM PMSSY 09 10 N B 53 Operating Head Light 1500 00 16 11 09 at 04 00 21 11 09 AT p m 11 00 AM 43 PGI MM PMSSY 09 10 N B 54 Volumetric Infusion Pump 20 000 00 16 11 09 at 04 00 21 11 09 AT p m 11 00 AM 44 PGI MM PMSSY 09 10 N B 55 Sleep Laboratory 7500 00 16 11 09 at 04 00 21 11 09 AT p m 11 00 AM 45 PGI MM PMSSY 09 10 N B 56 Spirometry system 3000 00 16 11 09 at 04 00 21 11 09 AT p m 11 00 AM 46 PGI MM PMSSY 09 10 N B 57 Body Plethysmograph system and Pulmonary 17500 00 16 11 09 at 04 00 21 11 09 AT Diffusion system p m 11 00 AM 47 PGI MM PMSSY 09 10 N B 58 Thoracoscopy System 7500 00 16 11 09 at 04 00 21 11 09 AT p m 11 00 AM 48 PGI MM PMSSY 09 10 N B 59 Nerve Stimulator 4000 00 16 11 09 at 04 00 21 11 09 AT p m 11 00 AM 49 PGI MM PMSSY 09 10 N B 60 Surgical Operating Microscope 15000 00 16 11 09 at 04 00 21 11 09 AT p m 11 00 AM 50 PGI MM PMSSY 09 10 N B 61 Hand Held Vascular Doppler 1500 00 16 11 09 at 04 00 23 11 09 AT p m 11 00AM 51 PGI MM PMSSY 09 10 N B 62 Basic Plastic Surgery Set 5000 00 16 11 09 at 04 00 23 11 09 AT p m 11 00AM 52 PGI MM PMSSY 09 10 N B 63 Micro Vascular Set 4500 00 16 11 09 at 04 00
45. 10 C 1 40 Heavy duty cooking range 1000 00 16 11 09 at 04 00 27 11 09 AT p m 11 00AM 104 PGI MM PMSSY 09 10 C 1 41 Internal air circulation system 1000 00 16 11 09 at 04 00 27 11 09 AT p m 11 00AM 105 PGI MM PMSSY 09 10 C 1 42 Heavy duty mobile storage drum Assorted 1000 00 16 11 09 at 04 00 27 11 09 AT p m 11 00AM 106 PGI MM PMSSY 09 10 C 1 43 Exhaust hood 1000 00 16 11 09 at 04 00 27 11 09 AT p m 11 00AM 107 PGI MM PMSSY 09 10 C 1 44 Miscellaneous Kitchen equipment 1000 00 16 11 09 at 04 00 27 11 09 AT p m 11 00AM 108 PGI MM PMSSY 09 10 C 1 56 Alignment software for sequencer 20000 00 16 11 09 at 04 00 27 11 09 AT p m 11 00AM 109 PGI MM PMSSY 09 10 C 1 136 Data mining tools and server 3000 00 16 11 09 at 04 00 28 11 09 AT p m 11 00AM 110 PGI MM PMSSY 09 10 C 1 137 Data Acquisition system a Intelligent 5000 00 16 11 09 at 04 00 28 11 09 AT Character Recognition system b Document p m 11 00AM scanner with ADF 111 PGI MM PMSSY 09 10 N B 97 Sequential Compression Device for 2500 00 16 11 09 at 04 00 28 11 09 AT Lymphedema p m 11 00AM 112 PGI MM PMSSY 09 10 C 3 05 Cytometer Bench Top 4 color analytical Flow 50000 00 16 11 09 at 04 00 28 11 09 AT Cytometer p m 11 00AM 113 PGI MM PMSSY 09 10 C 3 06 Electrophysiology ablation apparatus 20000 00 16 11 09 at 04 00 28 11 09 AT p m 11 00AM 114 PGI MM PMSSY 09 10 C 3 07 Isocentric Brachytherapy Simulator 50000 00 16 11 09 at 04 00 28 11 09 AT p m 11 00AM 1
46. 15 PGI MM PMSSY 09 10 C 3 09 Videotelemetry system 12500 00 16 11 09 at 04 00 28 11 09 AT p m 11 00AM 116 PGI MM PMSSY 09 10 N B 98 Clinical Chemical Auto Analizer 8000 00 16 11 09 at 04 00 28 11 09 AT p m 11 00AM 117 PGI MM PMSSY 09 10 N B 99 Syringe Infusion Pump 2500 00 16 11 09 at 04 00 28 11 09 AT p m 11 00AM 118 PGI MM PMSSY 09 10 N B 100 Fibreoptic Vidobronchoscopy system 14000 00 16 11 09 at 04 00 28 11 09 AT p m 11 00AM 119 PGI MM PMSSY 09 10 N B 101 C Arm high end 25 000 00 16 11 09 at 04 00 28 11 09 AT p m 11 00AM 120 PGI MM PMSSY 09 10 N B 102 Advance Neonatal Incubator 4500 00 16 11 09 at 04 00 28 11 09 AT p m 11 00AM 121 PGI MM PMSSY 09 10 N B 103 Incubator Transport 4500 00 16 11 09 at 04 00 28 11 09 AT p m 11 00AM 122 PGI MM PMSSY 09 10 N B 104 Infant Open Care System for NICU 2000 00 16 11 09 at 04 00 28 11 09 AT p m 11 00AM 123 PGI MM PMSSY 09 10 N B 105 Transducer Bilirubinometer 1000 00 16 11 09 at 04 00 28 11 09 AT p m 11 00AM 124 PGI MM PMSSY 09 10 N B 106 Laproscopic Equipmentsl 10000 00 16 11 09 at 04 00 28 11 09 AT p m 11 00AM 125 PGI MM PMSSY 09 10 N B 107 Burns Bath Treatment Unit with Lifting System 8000 00 16 11 09 at 04 00 28 11 09 AT p m 11 00AM 126 PGI MM PMSSY 09 10 N B 108 Paitent Hoist with Integrated Weighting Scale 3500 00 16 11 09 at 04 00 28 11 09 AT p m 11 00AM 127 PGI MM PMSSY 09 10 N B 109 Laproscopic Equipment for maternal amp
47. 5 mm wide 120 mm deep Blade 60 mm wide 160 mm deep 75 Doyen bladder retractor Length 25 cms Blade 53mm depthx80mm width 76 Daever retractors Standard pattern flexible 18 cms long 19 mm wide 23 cms long 25 mm wide 30 cms long 38 mm wide 77 MIKULICZ abdominal retractors for Blade 35 mm wide x 91 mm deep length 24 deep abdominal surgery 26 cms cms Blade 55 mm widex 86 mm deep length 25 5 cms Blade 50 mm widex 121 mm deep length 25 0cm 78 St Marks pelvic retractor Blade 174x60mm length 330mm 79 Rochard table mounted self retaining Mounted frame for fastening to the lateral bars abdominal retractor both sides of the operating table Blade sizes 48 x 90mm 48 x 120mm 80 Weitlaner self retaining retractor Standard pattern with prongs Length 11 cms semi sharp prongs Length 13 cms semi sharp prongs 81 82 Balfour baby self retaining abdominal retractor Balfour self retaining abdominal retractor Length 16 5 cms semi sharp prongs Lateral blades 27mm deep central blade 21 x 24 mm Lateral blade 60mm deep central blade 47 x 80mm Lateral blade 60 mm deep central blade 80 x 80 mm 83 Denis Browne self retaining retractor Frame 175 x 150 mm 4 blades 40 x 30 mm 4 blades 20 x 30 mm 84 Finechietto rib retractor Blades 12x15 mm Shaft length 95mm blades 18 x 21 Shaft length 180 mm blades 28 x 32 Shaft length 200mm blades 36x45 Shaft length 260mm blades 65 x 65
48. 55MM BABCOCK ATRAUMATIC FORCEPS 160MM 92 BABCOCK TISSUE FORCEPS 220MM 93 KIEBACK HYSTRECTOMY SCISSOR 90DEGREE 240MM 94 KOCHER OCHSNER FORCEPS STRAIGHT 1x2 225MM 95 96 KOCHER OCHSNER FORCEPS CURVED 1x2 225MM DUROGRIP CRILE WOOD NEEDLE HOLDER 145MM 97 DUROGRIP HEGAR MAYO NEEDLE HOLDER 205MM 98 DUROGRIP HEGAR NEEDLE HOLDER 205MM 99 DUROGRIP HEGAR NEEDLE HOLDER 245MM 100 MASSON NEEDLE HOLDER 265MM 101 MAYO HEGAR NEEDLE HOLDER 195MM 102 103 DOYEN MYOMA SCREW 190MM DOYEN RETRACTOR 90x35MM 242MM 104 MORRIS RETRACTOR 70x65MM 105 SEMM ABDOMINAL RETRACTOR COMPLETE 106 ROUX RETRACTOR DOUBLE ENDED SET OF 3 107 108 VOLKMANN RETRACTOR SEMI SHARP 4 PRONGED KOCHER ABDOMINAL RETRACTOR 109 VAGINAL RETRAC TUEBINGER PATT 95X20MM 110 SURGICAL DRUM SMALL MEDIUM AND BIG 111 TRAY WITH LID SMALL MEDIUM AND BIG SIZE 112 HABERER ADOMINAL SPATULA MALLEAB TAP 113 MICRO SCISS SPRING TYPE ROUND HDL 145MM 114 SPRING SCISSORS MICRO MILLESLSTR 160MM 115 MICROSCOPIC FORCEPS NO 7 115MM LONG 116 SUTURE TYING FORCEPS 150MM CURVED 117 MICRO ADSON BIEMER TISS FORC 1 X2T 120MM 118 DUROGRIP GRUENWALD DISS FORCEPS 185MM 119 MICRO NEEDLEHOLDER 150MM CVD WITH RATCH 120 JACOBSON NEEDLE HOLDER W CATCH 185 MM 121 SIMPSON OBSTETRICS FORCEPS 23CM LONG 122 WRIGLEY OBSTE
49. 85 Table mounted self retaining abdominal retractor system For infants amp smaller children For older children amp adolescents Table mounted self retaining retractor system with assorted types and sizes of retractor blades Retractor blades Richardson Kelly malleable baby Harrington Daever etc 86 Benson s pyloric muscle spreader Length 155 mm Rectal surgery instruments 87 Killian rectal speculum for children Length 145 mm blade 70 mm x 7 mm 88 Sims rectal speculum for children Length 19cm blade 60 x 20 mm 89 Parks rectal spreader Consisting of spreader 2 lateral blades one central blade with cold light carrier Lateral blades 70mm deep 90 St Marks Modif Girona perineal Perineal spreader spreader 91 Rectal suction biopsy forceps For taking rectal mucosal amp submucosal biopsies in newborns amp infants Has 3 detachable tips 92 Punch biopsy forceps for rectum Handle 140mm Shaft 250mm 93 Fistula probes Straight tip Curved tip 45 degree angle 94 Uterine Hegar dilator set Diameter ranging from I mm 26 mm Electrosurgical instruments 95 Electrosurgical Metzenbaum dissecting 180 mm length fine tip Scissors 96 Electrosurgical monopolar forceps 130 mm length 200 mm length 97 Electrosurgical bipolar forceps 16 cms length straight tip 9 mm Suction instruments 98 Pool sump suction tip Suction canula with outer tube to be screwed off Length 22 5 cm
50. 85 Hybridization Oven 1000 00 16 11 09 at 04 00 27 11 09 AT p m 11 00AM 91 PGI MM PMSSY 09 10 N B 86 Thermo Cycler 2500 00 16 11 09 at 04 00 27 11 09 AT p m 11 00AM 92 PGI MM PMSSY 09 10 N B 87 Gel Documentation System 2500 00 16 11 09 at 04 00 27 11 09 AT p m 11 00AM 93 PGI MM PMSSY 09 10 N B 88 Microwave oven 1000 00 16 11 09 at 04 00 27 11 09 AT p m 11 00AM 94 PGI MM PMSSY 09 10 N B 89 pH meter 1000 00 16 11 09 at 04 00 27 11 09 AT p m 11 00AM 95 PGI MM PMSSY 09 10 N B 90 Vortex mixture 1000 00 16 11 09 at 04 00 27 11 09 AT p m 11 00AM 96 PGI MM PMSSY 09 10 N B 91 Homogenizer 1000 00 16 11 09 at 04 00 27 11 09 AT p m 11 00AM 97 PGI MM PMSSY 09 10 N B 92 Sonicator 1250 00 16 11 09 at 04 00 27 11 09 AT p m 11 00AM 98 PGI MM PMSSY 09 10 N B 93 Microarray technology system 50000 00 16 11 09 at 04 00 27 11 09 AT p m 11 00AM 99 PGI MM PMSSY 09 10 N B 94 Co2 Incubator 2500 00 16 11 09 at 04 00 27 11 09 AT p m 11 00AM 100 PGI MM PMSSY 09 10 N B 95 HPLC High Protein Lipid Chromotography 3000 00 16 11 09 at 04 00 27 11 09 AT p m 11 00AM 101 PGI MM PMSSY 09 10 N B 96 Electrophoresis System 1500 00 16 11 09 at 04 00 27 11 09 AT p m 11 00AM 102 PGI MM PMSSY 09 10 C 1 114 Biological Safety Cabinet 2500 00 16 11 09 at 04 00 27 11 09 AT p m 11 00AM 103 PGI MM PMSSY 09
51. 85MM SEBILEAU ELEVATOR 173MM 5 0 MM WIDE BEYER BONE RONGEUR 180 MM BONE CUTTING FORCEPS 175 MM BONE HOLDING FORCEPS SLENDER PATT 200MM BONE GRAFTING SCALPEL HANDLE NO 4 VOLKMANN RETRACTOR SEMI SHARP 2 PRONGED LANGENBECK RETRACTOR 40X10MM 210MM WEITLANER RETRACTOR 3X4 TEETH SEMI SHARP FARABEUF RASPATORY CURVED DOYEN RASPATORY ADULT SIZE LEFT SIDE DOYEN RASPATORY ADULT SIZE RIGHT SIDE DINGMANN BONE HOLDING FORCEPS 185 MM LANGENBECK BONE HOLDING FORCEPS GIERTZ STILLE RIB SHEARS 250 MM GOUGE WALTHER 203 MM LONG 10 MM GOUGE WALTHER 203 MM LONG 15 MM STILLE OSTEOTOME STRAIGHT 15 MM STILLE OSTEOTOME STRAIGHT 20 MM 3 OTOPLASTY EAR SURGERY SET OTOPLASTY SET GROSS POLYPUS SPONGE AND DRESS FORCEPS BACKHAUS TOWEL HOLDING FORCEPS 110MM TOWEL CLAMP 115 MM LENGTH SCALPEL HANDLE NO 3 SCISSORS DELICATE CURVED 120 MM DISSECT AND STRABISMUS SCISS CVD 115MM OP SCISSORS STR BL SH 145 MM S ADSON FORCEPS FINE SERRATED JAWS 120MM ADSON FORCEPS 1X2 TEETH 120 MM DISSECTING FORCEPS SLEND PATT 145 MM TISSUE FORCEPS AM PATT 1X2 T 145MM MICRO HALSTED HEMOST FORC CVD 125 MM PEAN ARTERY FORCEPS STRAIGHT 140 MM COTTLE SEPTUM KNIFE 140 MM FREER ELEVATOR SHARP BLUNT 185MM COTTLE SKIN HOOK CURVED 180 DEGR JOSEPH HOOK 2 SHARP PRONGS 165MM FERGUSSON SUCT CANN D 2 5MM WORK L 1 10MM FERGUSSON SUCT CANN D 3 0MM WORK L 1 10MM DUROGRIP HALSEY NEEDLE HOLDER 130 MM LABORATORY DISH
52. AN arg RAEBARELI ROAD LUCKNOW 226 014 Phones 2668004 8 2668700 2668800 2668900 FAX 91 522 2668 218 JDMM Notice Inviting Tender SANJAY GANDHI POST GRADUATE INSTITUTE OF MEDICAL SCIENCES Sealed offers are invited from manufacturer Direct Importers Authorized Distributors Authorized Agents for the Supply of medical equipments instruments amp supportive items like Gynecology Examination Table amp Light Maternal amp Fetal Monitor 2D amp 4D Ultrasound Surgical Instruments Pediatric Thermal Blanket amp Mattress Pediatric Operating Table etc under PMSSY The offers may be submitted based on FOB amp CIF in case of import and FOR SGPGIMS Lucknow in case of indigenous Detailed information amp specification may be downloaded from our website WWW Sgpgi ac in Advt No 57 2009 10 Notice Inviting Tender Adv No 57 2009 10 Sealed offers are invited from reputed manufacturers Direct Importers Authorized Distributors Authorized Agents for supply of the following Equipments as per the conditions stipulated in the tender documents SI No Tender No Name of items EMD Rs Last Date of Date of submission of Opening of Tender Tender 1 PGI MM PMSSY 09 10 N B 01 Gynecology Examination Table 1500 00 16 11 09 at 04 00 18 11 09 at p m 11 00AM 2 PGI MM PMSSY 09 10 N B 12 E
53. AS Expansion 10 64 bit 100MHz PCL X Removable Media Bays 3 Storage Controller Smart Array P400 Controller Deployment Networking Dual NC371 1 multi faction Gigabit NICs Ports Front 2 USB 2 0 1 IEEE 1394 optional Remote Management Standard Integrated Light Out 2 1LO2 technology Redundant Power Supply Hot Plug 910 w 1300w Display Monitor 17 TFT 1280x 1024 Resolution Keyboard amp Mouse Standard Chassis Tower OS Windows XP Server or latest Warranty year S 5 years comprehensive on site lining Toll P3 Items a SAS Ver 9 2 or higher Single user academic license along with media and manuals with following modules SAS Base SAS Genetics SAS Graph SAS GIS SAS STAT SAS OR SAS App Dev Studio SAS Tutor SAS Enterprise Miner b Neuroshell single user academic license with media and user manuals c Matlab Ver 14 0 or later single user academic license with media and user manual PGI MM PMS Data Acquisition System a Intelligent Character Recognition System b Document Scanner with el ADF Data Acquisition System a Work Station Specification Processors Intel Xenon 3 60 GHz 800 MHz FSB 2 MB L2 cache lintel Chipset Memory 16 GB extendable up to 128 GB Drive bays 2 3 5 internal 2 5 25 external 1 3 5 external Hard drive 250 GB 15000rpm Ultra 320 SCSI 2 Nos Optical drive 16XDVD RW Dual Layer Light Scribe Monitor 17 TFT 1280X1024 Audio Integrated AC97 Audio with internal speaker s
54. Applications System should be the latest state of art fully digital DICOM compatible colour Doppler system Capable of producing images of high diagnostic quality for whole body clinical application both adult amp paediatric Should have facility for imaging abdomen pelvis small parts thyroid breast testis musculoskeletal transcranial neonatal cranial amp spinal cardiovascular peripheral vascular endocavitary TV TR Facility for ultrasound guided interventions like image guided drainage and biopsy with clear visualization of the needle Suitable for intra operative imaging of solid organs like liver and intraoperative Doppler for vessels Imaging modes Should have the following modes 2D B B mode B M mode 4B mode M mode spectral Doppler pulse wave PW continuous wave CW Doppler colour flow imaging colour power angio directional colour power angio imaging 3D with multiplanar reformatting Doppler Tissue Imaging DTD Colour M mode Duplex mode Triplex mode Virtual format Dual from freeze split Zoom anatomical M mode live cine loop and DIMAQ image review Colour Doppler velocity mode ECG trace in all modes System specifications System should be compact amp ergonomically designed latest state of art Please mention the year when the system was launched System should be easy to use and with facility to to upgrade to keep pace with rapidly changing technology please mention the option of such upgradabili
55. EEL CONTROL VALVES FOR PROCESS OF AUTOCLAVING AND ALSO FOR MANUAL OPERATION AS 1 STEAM TO JACKET THROUGH PRV 2 JACKET TO CHAMBER 3 EXHAUST FAST amp SLOW 4 VACUUM AND DRY 5 DIRECT STEAM DISCHARGE LINE OPERATION OPTION AUTOMATIC THE SYSTEM CYCLE SHOULD INDICATE THE FOLLOWING PARAMETERS ON LED DISPLAY 1 CYCLE NUMBER B LOADING INFORMATION C DATE D STERILIZATION DURATION E TOTAL PROCESS TIME F ALARMS FOR MALFUNCTION 2 CHAMBER AIR LEAK TEST PULSING AIR REMOVAL SYSTEM WITH DETECTION BY BOWIE DICK TEST 4 REAL TIME DATA REAL TIME TEMPERATURE AND GRAPH OF TEMPERATURE INDICATION DEGREE CENTIGRADE VERSUS TIME IN MINUTES WITH SET POINT SHOWING THE SELECTED STERILIZATION TEMPERATURE ON STRIP CHART RECORDER 5 RETRIEVAL OF DATA STORAGE ALL IMPORTANT INFORMATION IN THE COMPUTER OF RECORD AND RETRIEVAL PURPOSE OF AT LEAST LAST 1000 ENTRIES 6 PRINTER PROVIDED FOR HARD COPY OTHERS 1 VACUUM PUMP ISIMAKE HIGH CAPACITY WATER RING VACUUM PUMP OF STANDARD COMPANY OF REQUIRED CAPACITY COMPLETE WITH CONDENSER AND FITTINGS FOR MECHANICAL AIR REMOVAL LE VACUUM PRE VACUUM AND DRYING POST VACUUM 2 NOISE CONTROL ANTI VIBRATION MOUNTING 3 ALL PIPES FITTING STAINLESS STEEL OF GRADE X 4 CR 19 NI 9 CONNECTION amp STAND ISS 304 SI oFIS 6911 4 STEAM GENERATOR S S STEAM GENERATOR WITH AUTOMATIC PRESSURE REGULATION amp OVER PRESSURE SAFETY amp MEETING ALL NECESSARY R
56. EQUIREMENTS 5 PLUG SCREEN ONE REMOVABLE PLUG SCREEN FOR CHAMBER DRAIN LINE TO BE PROVIDED 6 BAFFLE 5 5 BAFFLE PLATE FOR EVEN DISTRIBUTION OF STEAM TO BE PROVIDED D TERMS AND CONDITIONS 1 INSTALLATION ON TURNKEY BASIS LE ONLY WATER ELECTRIC AND STEAM SOURCE AT SITE WILL BE PROVIDED ALL CONTROL LIKE ICPT SWITCH INPUT VALVES AND PRV IF REQUIRED SHOULD BE PROVIDED INSTALLED BY THE SUPPLIER 2 ISI CERTIFICATE AND LIST OF USERS INSTALLATIONS OF RECTANGULAR STERILIZER MAY BE PROVIDED 3 THE SUPPLIER WILL PROVIDE 2 SETS OF OPERATING MANUAL AND CIRCUIT DIAGRAM AND A 4 GUARANTEE WARRANTY OF 05 YEARS SERVICE MANUAL 8 OFFER FOR BOTH COMPREHENSIVE LABONR amp SPARE MAINTENANCE AND NON COMPREHENSIVE ONLY LABOUR AND PRICE LIST OF SPARE PART WITH VALIDITY OF RATES TO BE PROVIDED 9 95 UPTIME DURING WARRANTY AS WELL AS DURING MAINTENANCE CONTRACT FINE PENALTY AS PER INSTITUTE TERMS 10 A COPY OF CERTIFICATE FROM BIS SHOULD BE ATTACHED ALL TESTING CERTIFICATES FOR THE JACKET CHAMBER AND ALL OTHER COMPONENTS USED SHOULD BE PROVIDED F Safety 4 IBR APPROVED PRESSURE REDUCING VALVES WITH GAUGES THE TENDERER SHOULD PROVIDE TRAPS IN LINES AND SAFETY VALVES FOR JACKET AND CHAMBER FOR OVER PRESSURE SAFETY 5 DOOR SAFETY TO PREVENT STARTING OF PROCESS UNLESS THE DOOR IS CLOSED AND OPENING OF DOOR WHEN THE CHAMBER IS PRESSURIZED 6 INSULATED SURFACE TO AVOID SCALDING TO OPERATOR PGI MM PM Sterilization
57. ERATOR B F G H MATERIAL OF CONSTRUCTION xii CHAMBER STAINLESS STEEL OF 316 OF IS 6911 OF 1992 xiii JACKET CARBON STEEL xiv DOOR STAIN LESS STEEL OF 304 OF IS 6911 oF 1992 xv DOOR GASKET HIGH TEMPERATURE RESISTANT SILICONE ELASTOMER TYPE SUITED FOR AUTOCLAVING OPERATION MATERIAL SHOULD BE NON TOXIC AND COMPLIES WITH THE REGULATIONS FOR AUTOCLAVING USE xvi INSULATION NON FIBER SHREDDING RESIN BONDED GLASS WOOL WITH S S COVERING OF 304 OF IS 6911 oF 1992 xvii DOOR HINGED TYPE WITH RADIAL ARMS WITH PROCESS LOCK TO PREVENT OPENING OF DOOR DURING THE PROCESS AND DOOR OBSTRUCTION SAFETY TO PREVENT CLOSING OF DOOR IN CASE OF AN OBSTRUCTION xvii MOUNTING ON STAINLESS STEEL TUBULAR STAND WITH LEVELING LUGS OF 6 xix VACUUM SYSTEM WATER RING TYPE VACUUM PUMP THE SHELL AND TUBE TYPE CONDENSER SHOULD BE FABRICATED FROM STAINLESS STEEL OF 304 xx STEAM SUPPLY THE STEAM GENERATOR SHOULD HAVE HEATERS OF REQUIRED ELECTRICAL LOAD AUTOMATIC PRESSURE CONTROLLER WITH GAUGE LOW WATER LEVEL CUT OFF SAFETY VALVES AND WITH UTMOST SAFETY FEATURES SHOULD BE OF STAIN LESS STEEL 316 WITH ARGON WELDING xxi STEAM TRAP BOTH CHAMBER AND JACKET SHOULD HAVE STANDARD STEAM TRAPS LOADING CAR CARRIAGE STAINLESS STEEL 316 GRADE OF IS 6911 OF 1992 WITH TWO SHELVES ENSURING A FLEXIBLE LOADING ARRANGEMENT xxii TROLLEY THE TROLLEY FOR LOADING AND UNLOADING OF MATERIAL PROCESS INDIVIDUAL STAINLESS ST
58. FC HCFC HFC refrigerant free air cooled hermetic compressors with dual condenser fans mounted on 4 castors Microprcessor controlled with touch pad data entry and digital display of all functions key operated main switch battery powered independent operating temperature and high low limit alarm functions for high low temp 10 K to set temperature automatic voltage boost to compensate for low voltage onboard power monitoring with display of incoming voltage Heated door sealing sturdy inner doors and minimum of 4 independent inner compartments high density door insulation door provision for padlock Compressor warranty of 5 years Optional Provision for vacuum release assembly for rapid opening of door for re entry racks boxes of different sizes and dividers for half the freezer230V AC 50 Hz cycle Eng PM Hybridization Oven shaker Specification 10 N B 85 Temperature controlled oven containing rotisserie and shaking platform for hybridization and incubation of Northern Southern and Western blots shaker platform and rotisserie for 6 bottles min capacity of 15 1 temperature range from ambient 5 C to 80 C temperature precision of 0 5 C temp fluctuation of 0 1 C auto cut off at 1 deg C over set temp retosserie speed 5 50 r m230V AC 50 Hz cycle Cove M Fully automated Thermocycler Specification 10 N B 86 Automated programmable thermal cycler capable of performing gradient PCR block holding capacity of 48 tubes
59. G with built pulse oximetry 3 LED based impedance display photic stimulation facility 4 44 channels 5 Acquisition software with following feature a poppe q r Even setting montage setting sensors grid electrode alarms amplifier etc Individual channel control Programmable control of montage selection with facility to change filter setting montages sensitivity of recording Graphical review of current montage during EEG recording Sort able list of all events placed in the recording automatically or manually Multiple audio and video compressor software to minimize the required space Video recording facility which should be optical to minimize the required disc space in long term monitoring Automatic line counters and event insertion during hyperventilation Spike and seizure detection software Spite screen facility for epilepsy monitoring with video on line patient and previously acquired patients can be review simultaneously CMRR of the amplifiers 115 dB analogue digital converter 22 bit ADC resolution voltage 0 153u V Noise 1 5 V PK PK 20 1 100Hz Network supported data management Work flow administration software User configurable file length of recording from 1 999 hours The dedication features deducts automatically any number of single multiple user defined events Facility to undertaking power spectral analysis Push button for patient attendant to register mark an event
60. LT IN BATTERY CHARGER e Should be able to Stimulate Motor Cerebral Nerves and Peripheral Nerves during the Intra Cranial Operation and Peripheral Nerve or Plexus Injuries e Unit Can be applied on fresh Nerve Injuries to locate the peripheral stump of the nerve as long as the wallerian degeneration has not taken place e Unit Can be used On Old injuries showing considerable scars e Unit can also be used to locate those motor nerves with only a partial loss e The unit should be able to determine the success of neurolysis whether the scar of a nerve has to be resected and the removed part replaced by a transplant e TECHNICAL DATA e Portable preferably hand held e Light Weight 500g 1 kg e Working time Atleast 48hrs after full charging e Mains Voltage240Volts compatible with Indian standards e Electrical mains cord for Charging 2 one backup e Accumulator e Extra battery backup free of cost e Stimulator Cable 2 in number e Coagulation and stimulator Forceps e Insulation with Connector Total Length 200mm TIP 0 9mm and finer e Facility for temporary replacement of instrument by same model for next three years during repairs at no extra cost e Carrying case for storage of equipment PGI MM PM SURGICAL OPERATING MICROSCOPE SSY 09 Specifications Quantity Reason 10 N B 60 MICROSCOPE BODY 1 Essential equipment for all types of Motorized zoom magnification system with apochromatic optics zoom magnificati
61. O RIGHT FERGUSSON SUCT CANN D 2 5SMM WORK L 110MM 6 BLEPHAROPLASTY Eye Lid Surgery SET BLEPHAROPLASTY GROSS POLYPUS SPONGE AND DRESS FORCEPS BACKHAUS TOWEL HOLDING FORCEPS 110MM TOWEL CLAMP 115 MM LENGTH SCALPEL HANDLE NO 3 STEVENS TENDON SCISSORS CVD SHARP 110MM STEVENS TENDON SCISSORS CVD BLUNT 110MM DISSECT SCISS METZENBAUM 145MM CVD DURO OP SCISSORS STR BL SH 145 MM S IRIS VERY FINE FORC 1X2T STR 100MM IRIS VERY FINE FORC 1X2T CVD 100MM ADSON FORCEPS FINE SERRATED JAWS 120MM ADSON FORCEPS 1X2 TEETH 120 MM MICRO HALSTED HEMOST FORC CVD 125 MM DIEFFENBACH ARTERY FORCEPS STR 38 MM DIEFFENBACH ARTERY FORCEPS STR 48 MM BARRAQUER MICRO NEEDLE HOLDER 120MM CVD DUROGRIP CRILE NEEDLE HOLDER 150 MM GRAEFE IRIS HOOK SHARP GUTHRIE IRIS HOOK SHARP COTTLE SKIN HOOK CURVED 180 DEGR LABORATORY DISH 0 16 L 7 KELOPLASTY Hand amp Tendon Surgery SET KELOPLASTY GROSS POLYPUS SPONGE AND DRESS FORCEPS BACKHAUS TOWEL HOLDING FORCEPS 110MM TOWEL CLAMP 115 MM LENGTH SCALPEL HANDLE NO 3 STEVENS TENDON SCISSORS CVD BLUNT I IOMM IRIS AND LIGATURE SCISSORS STR 110 MM OP SCISSORS STR BL SH 145 MM S GRAEFE FIXATION FORCEPS 110MM IRIS VERY FINE FORC 1X2T STR 100MM MICRO HALSTED HEMOST FORC CVD 125 MM ROCHESTER PEAN ARTERY FORCEPS STR 160MM DUROGRIP CRILE NEEDLE HOLDER 150 MM CASTROVIEJO EYE CALIPER LABORATORY DISH 0 16 L 8 RHINOPLASTY Nasal Surgery SET
62. OR THE JACKET CHAMBER AND ALL OTHER COMPONENTS USED SHOULD BE PROVIDED F Safety 1 IBR APPROVED PRESSURE REDUCING VALVES WITH GAUGES THE TENDERER SHOULD PROVIDE TRAPS IN LINES AND SAFETY VALVES FOR JACKET AND CHAMBER FOR OVER PRESSURE SAFETY 2 DOOR SAFETY TO PREVENT STARTING OF PROCESS UNLESS THE DOOR IS CLOSED AND OPENING OF DOOR WHEN THE CHAMBER IS PRESSURIZED 3 INSULATED SURFACE TO AVOID SCALDING TO OPERATOR Surgical Instruments For Paediatric Surge Sl no Instrument Specifications Scissors 1 Stevens tenotomy scissors Tapering fine tip Curved 12 5 cms 5 2 Reynolds scissors Fine pointed 145 mm 175 mm 3 Metzenbaum curved scissors Tungten carbide cutting edge gold plated rings 14 5cms Curved 16 cms curved 18 cms curved 20 cms curved 4 Metzenbaum curved scissors 14 5cms Curved 16 cms curved 18 cms curved 20 cms curved 4 Metzenbaum straight scissors 16mm 20mm 5 Potts scissors Fine pointed curved 180 mm 6 Micro scissors Curved amp straight 120mm 160mm Dissecting and tissue forceps 7 Micro adson tissue forceps non 120mm toothed 8 Me Indoe toothed tissue holding Delicate extremely fine teeth forceps 15cms 6 9 Gerald toothed tissue holding forceps 17 5 cms straight 10 Waugh toothed tissue holding forceps 20 cms straight 11 Mc Indoe tissue holding forceps non 6 15 cm toothed 12 Cushing s tissue
63. PGI MM PM Flexible Cystoscope SSY 09 10 C 1 130 Specification Instrument channel PGI MM PM Water Purification System SSY 09 10 C 1 36 Specification Water purification system for delivering up to 5 L h of Type II water 15 Analytical grade as defined by ISO 3696 3997 from tap water certified for feed water quality at SGPI which would fulfill requirements for feed water of an ultra filtration system gt 5 M Q cm resistively and lt 0 2 u s cm conductivity of product water compensated to 25 deg C TOC of lt 30 ppb bacteria count of lt 1 cfu ml silicate content lt 99 9 retention and min water recovery of 15 maintenacene free with storage tank of min 30 L capacity Water purification system for producing upto 1 0 Min of ultrapure Type water from feed water of type II with gt 10 M Q cm receptivity of product water compensated to 25 deg c TOC of 5 10 ppb pyrogens 0 001 Eu mL bacteria count of 1 cfu mL 230 VAC 50 Hz cycle Microfuge Centrifuges Refrigerated Centrifuge Specifications as below 10 N B 78 1 Capacity 24 x 1 5 2 ml microtubes 2 Minimum speed 15 000 rpm 3 Minimum RCF 21 500 xg 4 Temperature Range 9 to 440 C 5 Display With self diagnostic system and error message 6 Rotor Autoclavable single microlitre rotor with 45 angle 7 Breaking profile Nine at least 8 Running Time gt 9h for continuous operation Safety Device Lid interlock imb
64. R ADOMINAL SPATULA MALLEAB TAP BRUNNER RETRACTOR BLADE 120X25 MM VOLKMANN RETRACTOR SEMI SHARP 4 PRONGED DUROGRIP CRILE NEEDLE HOLDER 150 MM DUROGRIP HEGAR MAYO NEEDLE HOLDER 185MM DUROGRIP DE BAKEY NEEDLE HOLDER 180 MM STEGMANN CUTTER MARKER 33MM STEGMANN CUTTER MARKER 38MM STEGMANN CUTTER MARKER 42MM STEGMANN CUTTER MARKER 48MM INTERIOR BOX FOR BL 930 NEEDLE CASE PERFOR 7 COMP 150X90X10MM LABORATORY DISH 0 16 L LABORATORY DISH 0 4 L KIDNEY TRAY 250 MM 10 LARGE RETRACTOR SET HANDLE WITH COLD LIGHT FOR BT801 820 VAGINAL BLADE 110X14 MM FOR BT 800 VAGINAL BLADE 110X23 MM FOR BT 800 WOUND RETRACTOR BLADE F BT800R 55X14MM WOUND RETRACTOR BLADE F BT800R 75X14MM WOUND RETRACTOR BLADE F BT800R 95X14MM WOUND RETRACTOR BLADE F BT800R 55X18MM COLD LIGHT FOUNTAIN STD 150WATT 220 V MAINS CORD 5 M LONG FIBER OPTIC LIGHT CABLE 4 8MM 1 8M LONG PGI MM PM Hand Held Dermatome SSY 09 10 N B 75 Specification The instrument should be of improved steel with high precision quality with CE TUV or ISO 9002 certification Each set should contain e 3 Baby Dermatome e 4 Regular Dermatome e 5 Dermatome e Sterile Throw Away Blades all sizes Box of 10 e Strerile sturdy container for all dermatomes e Container should be autoclaveable PGI MM PM Watson amp Silverman Skin Grafting Knife Handle SSY 09 10 N B 76 6 The instruments should be improved steel
65. S 4X4 TEETH 200 MM BABY MIXTER ARTERY FORCEPS 180MM DUROGRIP NEEDLEHOLDER RYDER 135MM DELIC DUROGRIP HALSEY NEEDLE HOLDER 130 MM DUROGRIP CRILE NEEDLE HOLDER 150 MM DUROGRIP HEGAR MAYO NEEDLE HOLDER 185MM LANGENBECK RETRACTOR 28X14MM 210MM LANGENBECK RETRACTOR 40X10MM 210MM LANGENBECK RETRACTOR 63X20MM 210MM VOLKMANN RETRACTOR SEMI SHARP 4 PRONGED VOLKMANN RETRACTOR SEMI SHARP 6 PRONGED SENN MILLER RETRACTOR DOUBLE ENDED WOUND AND TRACHEAL HOOK SHARP 1 TOOTH WOUND AND TRACHEAL HOOK BLUNT I TOOTH DESMARRES LID RETRACTOR DESMARRES LID RETRACTOR FINE SKIN RETRACTOR GILLIES 180MM SMALL FINE SKIN RETRACTOR GILLIES 180MM LARGE VOLKMANN SPOON SHARP SIZE 00 VOLKMANN SPOON SHARP SIZE 1 VOLKMANN SPOON SHARP SIZE 3 STEEL RULER GRAD IN MM A INCHES 300MM PROBE DOUBLE ENDED 145 MM DIAM 1 0MM PROBE DOUBLE ENDED 160MM DIAM 1 5 MM PROBE DOUBLE ENDED 180MM DIAM 2 0 MM INTERIOR BOX FOR BL 930 NEEDLE CASE PERFOR 7 COMP 150X90X 10MM LABORATORY DISH 0 16 L LABORATORY DISH 0 4 L KIDNEY TRAY 250 MM 2 SET FOR LARGE BONE SURGERY HAMMER COTTLE CHISEL LEXER 220MM LONG 5 MM WIDE LEXER OSTEOTOME 220MM 10 MM WIDE LEXER OSTEOTOME 220MM 15 MM WIDE GOUGE LEXER 220MM LONG 5 MM WIDE LEXER GOUGE 220MM 10 MM WIDE LEXER GOUGE 220MM 15 MM WIDE WILLIGER RASPATORY 160MM LONG 6 0MM WIDE RASPATORY W HARTPR HDL CVD STR BL 6MM RASPATORY HARDPR HANDLE CVD RND CUT 6MM FREER ELEVATOR SHARP BLUNT 1
66. SORS WERTHEIM 230 MM 63 UTERUS SCISS SIMS DUROTIP BLUNT P DULL 230 MM 64 DUROTIP LIGATURE SCISSORS 180MM LONG 65 66 OP SCISSORS Straight BL SH 145 MM DISSECTING FORCEPS SLEND PATT 145 MM 67 TISSUE FORCEPS AM PATT 1X2 T 145MM 68 TISSUE FORCEPS 1X2 TEETH 200 MM 69 TISSUE FORCEPS 1X2 TEETH 250 MM 70 TISSUE FORCEPS 1X2 TEETH 145 MM 71 72 STANDARD FORCEPS SERRATED 180 MM FORCEPS STRAIGHT 2MM JAW ATRAUMATIC 150MM 73 FORCEPS STRAIGHT 2MM JAW ATRAUMATIC 200MM 74 FORCEPS STRAIGHT 2MM JAW ATRAUMATIC 240MM 75 WAUGH FORCEPS 1X2 TEETH 180 MM 76 ROCHESTER OCHSNER FORCEPS STRAIGHT 1X2Teeth 140MM 77 PEAN ARTERY FORCEPS STRAIGHT 140 MM 78 79 KOCHER HYSTERECTOMY FORCEPS STRAIGHT 200 MM KOCHER HYSTERECTOMY FORCEPS STRAIGHT 240 MM 80 MIKULICZ PERITONEUM FORCEPS LARGE 205MM 81 OVERHOLT GEISSENDOERFER DISS FORCEPS 220 MM 82 OVERHOLT GEISSENDOERFER DISS FORCEPS 225 MM 83 84 CRILE HAEMOSTATIC FORCEPS CURVED 160MM BABY CRILE HAEMOSTATIC FORCEPS CURVED 140MM 85 HALSTED MOSQUITO HAEM FORCEPS 200MM STRAIGHT 86 HALSTED MOSQUITO HAEM FORCEPS 200MM CURVED 87 GREEN ARMYTAGE FORCEPS ANGLED 195MM 88 GREEN ARMYTAGE FORCEPS STRAIGHT 220MM 89 ALLIS ATRAUMATIC FORCEPS 8 4MM 255MM 90 91 ALLIS ATRAUMATIC FORCEPS 6 2MM 1
67. Self Diagnostics check at power up 20 presets for different parameter setups Digital timer 9 hrs 59 mins 59 secs digital wattmeter 230V AC 50 Hz cycle Ae ene Advance Neonatal Incubator 10N B 102 2bectication Should be a microprocessor controlled system with future expandability spared for additional functions Setting range from 35 C 37 C in increments of 0 1 C Measurement of near to core temperature Servo control for Oxygen and Humidity with integrated monitoring Should support kangaroo care with extra low height adjustment 80 cm Alarm management continuous monitoring of baby temperature for the time CO2 flushing according to IEC 601 2 19 105 1 Maximum CO2 concentration inside incubator 0 2 96 Height adjustable with low noise electrical paddle on either side Programmable alarms and safety features Noise level 47 Db Alarms for Probe failure High temperature amp Power failure Warming time 35 minutes from 20 C to 31 C Air speed over bed 8 cm sec Continuous bed tilts up to 8 on either sides Optional integral weighing scale electrical Incubator should have special hump ports to give access doors main doors side doors at least two access canopy tubing port and sizeable bed area with mattress Incubator should have double walls on outside including canopy top to prevent heat loss Tilt mechanism assembly should be outside infant s compartment to avoid disturbance of infant X ray ta
68. TERINE VULSELLUM FORCEPS 270 MM 31 BRAUN UTERINE DEPRESSOR 270MM 32 SIMS UTERINE PROBE GRADUATED CURVED 330MM 33 ZWEIFELA UTERINE CURETTE DOUBLE ENDED 31CM LONG 34 35 HY WOOD SMITH POLYP FORCEPS STRAIGHT 250MM MAIER POLYPUS SPONGE AND DRESS FORCEPS 36 COLLIN UTERINE ELEVATING FORCEPS 265 MM 37 HEGAR UTERINE DILATOR 1 2MM 195MM 38 HEGAR UTERINE DILATOR 3 4MM 195MM 39 HEGAR UTERINE DILATOR 5 6MM 195MM 40 HEGAR UTERINE DILATOR 7 8MM 195MM 41 42 HEGAR UTERINE DILATOR 9 10MM 195MM HEGAR UTERINE DILATOR 11 12MM 195MM 43 HEGAR UTERINE DILATOR 13 14MM 195MM 44 HEGAR UTERINE DILATOR 15 16MM 195MM 45 HEGAR UTERINE DILATOR 17 18MM 195MM 46 47 CHEATTLE STERILIZING FORCEPS 280MM EPIOSOTOMY SCISSOR CURVED BLADE 240MM 48 ROUND BOWL 0 16 L 49 ROUND BOWL 0 4 L 50 KIDNEY TRAY 170 MM 51 KiDNEY TRAY 250 MM 52 KIDNEY TRAY 275 MM 53 54 PROBE DOUBLE ENDED 300MM DIAM 2 0 MM GUIDE PROBE 4 5MM BROAD 195 MM 55 BACKHAUS TOWEL HOLDING FORCEPS 110MM 56 FOERSTER SPONGE HOLD FORC SERRAT JAWS Straight 57 SCALPEL HANDLE NO 4 58 59 SCALPEL HANDLE NO 3 DUROTIP DISS SCISS METZENBAUM Curved 200MM 60 DUROTIP DISS SCISS NELSON METZENBAUM Curved 230MM 61 DUROTIP DISS SCISS MAYO LEXER Curved 165MM 62 DUROTIP DISSECT SCIS
69. TRIC FORCEPS 28CM LONG DITTEL URETHRAL BOUGIES AND DILATING SOUNDS STIFF 123 345MM FEMALE CATHETER METAL 155MM 124 PGI MM PM SSY 09 10 N B 25 PGI MM PM SSY 09 10 C 2 05 Electronic baby weighing machine Specification Microprocessor based Electronic weighing machine should have large digital display with easy visibility Unit should have 0 120 kg range and 10 gm accuracy Should have facility to weigh moving patient using electronic software freeze averaging facility Should have display freeze facility which helps to note the weight even after baby is taken off the scale Space for lying babies with dropdown sides sitting babies and platform for standing patients should be provided It should have following features e Capacity 120 kg e Resolution 10 gms e Accuracy 10 gms throughout the range e Portable Mobile Static Mobile Static e Weight in Kg approx 15 Kg e Baby pan approx 520 X 280 mm e Electrical Specifications 220V AC 50 Hz Description of Horizontal High Pressure High Vacuum Steam Sterilizer e QUANTITY 01 NO SPECIFICATION e SIZE 24 CUBIC FEET e SHAPE HORIZONTAL RECTANGULAR e CHAMBER DIMENSION 600X900X1200 MM e STANDARD ISI AND COMPATIBLE TO INTERNATIONAL STANDARDS e CAPACITY 640 LTS e WORKING TEMPERATURE 121 C AND 134 C e WORKING PRESSURE 1 2KG CM2 TO 2 2 KG CM2 e HYDRAULIC TEST DOUBLE OF
70. VES AND WITH UTMOST SAFETY FEATURES SHOULD BE OF STAIN LESS STEEL 316 WITH ARGON WELDING x STEAM TRAP BOTH CHAMBER AND JACKET SHOULD HAVE STANDARD STEAM TRAPS LOADING CAR CARRIAGE STAINLESS STEEL 316 GRADE OF IS 6911 oF 1992 WITH TWO SHELVES ENSURING A FLEXIBLE LOADING ARRANGEMENT xi TROLLEY THE TROLLEY FOR LOADING AND UNLOADING OF MATERIAL PROCESS INDIVIDUAL STAINLESS STEEL CONTROL VALVES FOR PROCESS OF AUTOCLAVING AND ALSO FOR MANUAL OPERATION AS 1 STEAM TO JACKET THROUGH PRV 2 JACKET TO CHAMBER 3 EXHAUST FAST amp SLOW 4 VACUUM AND DRY 5 DIRECT STEAM DISCHARGE LINE OPERATION OPTION AUTOMATIC THE SYSTEM CYCLE SHOULD INDICATE THE FOLLOWING PARAMETERS ON LED DISPLAY 1 A CYCLE NUMBER B LOADING INFORMATION C DATE D STERILIZATION DURATION E TOTAL PROCESS TIME F ALARMS FOR MALFUNCTION 2 CHAMBER AIR LEAK TEST PULSING AIR REMOVAL SYSTEM WITH DETECTION BY BOWIE DICK TEST 1 REAL TIME DATA REAL TIME TEMPERATURE AND GRAPH OF TEMPERATURE INDICATION DEGREE CENTIGRADE VERSUS TIME IN MINUTES WITH SET POINT SHOWING THE SELECTED STERILIZATION TEMPERATURE ON STRIP CHART RECORDER 2 RETRIEVAL OF DATA STORAGE OF ALL IMPORTANT INFORMATION IN THE COMPUTER OF RECORD AND RETRIEVAL PURPOSE OF AT LEAST LAST 1000 ENTRIES 3 PRINTER PROVIDED FOR HARD COPY OTHERS 1 VACUUM PUMP ISIMAKE HIGH CAPACITY WATER RING VACUUM PUMP OF STANDARD COMPANY OF REQUIRED CAPACITY COMPLETE WITH CONDENSER AND
71. al for routine analysis With up to three decimal place resolution and a choice of up to three calibration points Should have pH resolution to 3 decimal places Calibration for 1 2 or 3 point RS232 connection to printer or PC via Data Way pH calibration buffers to DIN JIS and NIST standards can be used for automatic calibration as well as manually entered buffer values pH range 2 000 to 19 999 pH resolution 0 001 0 01 0 1 pH accuracy 40 003 Automatic buffer recognition Jenway 2 00 4 00 7 00 9 20 and 10 00 DIN NIST JIS Calibration User selectable 1 2 or 3 point mV range 1999 9mV mV resolution 0 1 1 mV mV accuracy 0 2mV Temperature range 10 to 105 C Temperature resolution 0 1 C Temperature accuracy 0 5 C ATC range 0 to 100 C Outputs Analogue and RS232 Connector BNC Should operate on 230 V 50 Hz Vortex Mixer Specification SSY 09 10 N B 90 PGI MM PM 1 Variable speed for gentle to vigorous mixing with timer function 2 Attachment for pop off cup Attachment for micro plates small and large ampoule tubes 4 Attachment for single multiple microtubes and various size tubes Attachment for bottle beakers an Attachment for violent mixing for cell disruption and homogenization I Base dimention 160 165x 120 125x 160 165mm D x W x H oo Operation system hands free and touch on Power supply AC line 50 Hz 220 240 volts Homogen
72. alance Detector Over current Circuit Breaker Power Switch Lid Open Close Detector Other Functions Memory storing a last used operating value FLASH momentary spin function Power Requirements Single phase 220 230 240V AC 50 60Hz 7A PGI MM PM SSY 09 10 N B 79 Table Top Centrifuges High speed Specification Maximum Speed 25 000 rpm Max Centrifugal Force 60 000G Max Capacity 250ml x 4 Temp Setting 9 C to 35 C Safety Mechanism Imbalance Detector Door interlocks Door open Close detection over Speed detection Circuit detector Temp error detection Rotor ID Electronic breaking Speed Force Temp and Time Control Digital Microprocessor Control Angle rotor with adaptors for 10 ml to 50 ml tubes Power requirements AC220 230 240V 50Hz 30A Warranty for 5 years PGI MM PM SSY 09 10 N B 80 Vacuum Concentrator Speed Vac Centrifuge Unit to include everything we need to dry alcohol or water based precipitates of DNA RNA yet occupies only 8 x 10 inches of bench space Built in pump and a by pass switch to allow the use of a stronger pump to shorten drying time Features a heating function to accelerate evaporation acrylic lid and a stainless steel chamber Centrifugal Vacuum Concentrator Complete system should include the Concentrator pump and rotor Compact and complete unit 20x 25x 23 cm Suitable for DNA RNA work Should have heating function to accelerate evaporation Speed 200rpm vacuum pump is mant
73. ambient temperature of 0 50deg C and relative humidity of 15 90 The unit shall be capable of operating in ambient temperature of 20 30 deg C and relative humidity of less than 70 6 Power Supply 6 1 6 2 Power input to be 220 240VAC Single Phase 400 440 V 3 Phase 50Hz as appropriate fitted with Indian plug UPS of suitable rating with back up of 20 minutes to be provided 7 Standards Safety and Training 7 1 7 2 Training Onsite application training for 15 days Complete On site Warranty from the Manufacturer for 5 years to be included Conditional warranty i e labour parts is not acceptable Exclusion of warranty of any part including consumables batteries local items etc during the warranty period is not accepted CMC is lieu of 23 7 4 7 5 7 6 warranty period in not acceptable No customs duty for spare parts imported during the warranty period will be paid by the institute Post warranty Comprehensive maintenance contract After the warranty period Comprehensive maintenance contract with taxes if applicable which including all spares X ray tube and generator imaging Amorphous silicon flat panel and other accessories of the system including local items to be quoted The supplier should provide comprehensive maintenance contract inclusive of customs duty and all taxes after the warranty period i e years 6 to 10 inclusive The CMC is to be within the range of 3 5 to 5 0 o
74. aphical data display sleep stage scoring interpretation of neurological and respiratory events the software should be compatible with Microsoft XP operating system 7 Facility for both automatic and manual analysis of data 8 Facility to set filter levels and sample rate for EEG EOG 9 Facility for electrode impedence testing 10 Facility to create customized templates for printing patient reports 11 Powered by rechargeable batteries or by 220 V 50 Hz AC current with battery backup batteries in either case should have capability to run the system for atleast eight hours 12 Weight less than 5 kg 13 Pentium IV computer with 2 8 GHz processor or better at least 100 GB hard disk at least one GB DDRAM CD and DVD writer 3 5 floppy drive keyboard optical mouse 17 monitor RS232 port atleast six USB 2 0 ports preloaded Windows XP Professional online UPS 14 All necessary cables software CDs and manuals 15 Warranty for two years 16 AMC CMC rates to be quoted for five years after expiry of five years warranty PGIMM PM Spirometry system M te Specification 7 1 Capability to measure FVC IVC VC MVV VT FEV1 FEV6 FEV1 FEV6 PEF PIF FEF 25 75 FEV1 VC MEF25 MEF50 MEF75 MV V 2 Interface with standard desktop laptop computer using Windows XP operating system 3 Meets current ATS recommendations on equipment accuracy 4 Volume measurement 0 to 10 litres DE Flow measurement 0 to 15 L sec 6 Real time Flow Volume and Volume T
75. aser s discretion to receive delivery with a reduction in price of the article or equipment Forced majeured shall mean and be limited to the following Any war hostilities Any riot or civil Communication Any earthquake flood tempest lighting or other natural physical disaster Any strike or lock out only those exceeding ten continues day in duration affecting the performance of the seller s obligations The seller shall advise the SGPGIMS by registered letter duly certified by Local Chamber of Commerce of Statuary authorities the beginning and end of the above causes of delay within7 seven days of occurrence and cessation of such Forced Majeure conditions in the event of delay lasting over one month if arising our causes of Force Majeure the SGPGIMS the right to cancel the order and the provisions governing termination state under articles shall apply For delays arising out of Forced Majeure the seller shall not claim extension in completion date for a period exceeding the period of delay attributable to the causes of Force Majeure and neither the SGPGIMS nor the seller shall be liable to pay extra costs provided it is Mutually established that Force Majeure conditions did actually exist The seller shall categorically specify the extent of Force Majeure conditions prevalent in his works such as power restriction etc at the time of submitting the bid and whether the same have taken into consideration or not in the quotations In the
76. atic and manual syringe loading Accepts all major syringe in sizes from 10 ml to 50 60 ml PGI MM PM SSY 09 10 N B 100 Fibreoptic Videobronchoscopy system Field of view 120 degrees Direction of view 0 degrees forward viewing Depth of field 3 100 mm Distal and outer diameter less than 6 mm Working length around 60 cm Inner channel diameter at least 3 2 mm Angulation range Up 160 180 degrees Down 110 130 degrees Electrocautery compatible LASER compatible Video monitor with ability to view the bronchoscopy procedure Computerized recording system to enter patient details to record and store the patient data Ability to generate avi and mpeg4 videos Ability to generate images at least 600 dpi Recording system compatible with windows vista and above I Laptop a operating system windows vista or better rp eco gom b atleast 320 gb hdd c atleast 4 gb ddr3 ram d weight less than 2 kilograms m Accessories a Cup biopsy forceps 5 b Alligator biopsy forceps 5 c Rat toothed forceps One two and three toothed Each5 d Dormia baskets 5 e TBNA needles 5 n PACS compatibility PGI MM PM SSY 09 10 N B 101 Specification For Mobile C Arm Gantry Carm The system should have a minimum of 75 cm free space within the C Arm to provide a large imagine space The C Arm depth should be 60 cm or deeper to provide
77. ating voltage 24VAC Neonatal intensive care incubator Specification Intensive care incubator with infant mode and air mode operational facility for prevention and clinical management of neonatal hypothermia Especially useful in the management of preterm low birth weight babies Continuously curved rounded hood for easy observation Air circulation system to reduce the infant s heat loss Digital display panel Mattress with a smooth continuous tilt mechanism X ray cassette tray Adjustable height from aprox 90 to 109cm Storage drawers Movable on four lockable castor wheels Servo double microcomputer for thermal and other controls Automatic servo humidity control to maintain preselected relative humidity with setting range of 40 95 1n 1 increment and display range of 15 99 Skin temperature setting range of 35 0 37 5 C with override mode of 37 6 39 0 C Air temperature setting range of 23 0 37 0 C with override mode of 37 1 39 0 C Inbuilt weight monitoring facility with memory and provision of print out having measuring range of 300 7000gm Servo controlled oxygen controller with oxygen concentration setting range of 22 65 Audio visual alarm for following Humidity Chamber off low water level relative humidity set point alarm humidity sensor alarm high temperature skin temperature probe set point system failure power failure oxygen sensor set oxygen concentration It should be CE ma
78. bility User programmable obstetrical tables and Estimation of fetal weight and Expected date of delivery from measurements should be automatically reflected in the report page e Automatic waveform trace in Doppler made with display of calculated values and indices in real time frozen image and recalled archived image Control Panel software and other features a All controls and trackball to be economically positioned for easy access and reduced operator fatigue b Full sized backlit alphanumeric keyboard with Interactive back lighting of control panel switches c Digital beam former with multiple at least four transmit foci and dynamic receive focus d System should have raw data processing technology e Should have 2500 or more processing channels f At least 256 Grey scale levels in displayed images Frame rate should be more than 600 F Sec g System dynamic range of 150dB or more h User programmable presets for different types of examinations 1 Automatic optimisation function that optimises the system parameters for B and Doppler modes This should be in addition to the presets for various examinations j Acoustic output display in mechanical and thermal indices k Frame by frame and continuous cine loop review of 150 or more images acquired just prior to ffeezing arVimage D Magnification with Scrolling jPanning in real time amp frozen modes m Multiple Pre amp Post processing functions and B Co
79. ble should be integrate in the matters to reduce disturbance of baby opening of canopy Should have integrated control panel with easy to use rotary knob with controls for and display of Temperature near and peripheral Humidity Weight trend data central alarm lamp Should have integrated trend display variable from three to seven days to track patient s central and peripheral temperature trend Control panel should display alarm messages with text display of alarm and severity of alarm Should have a large storage drawer integrated into the main unit Incubator should confirm to relevant EN standard for Electrical Safety and should have CE and FDA approvals Standard scope of supply must include o Skin temperature probe Bed tilting faction Integrated X Ray Drawer Pullout bet rays Soft mattress Central Alarm light Kangaroo Mode Skin Air temp control Humidity regulation Oxygen regulation Optional cost of integral weighing scale Electrostatic fitter Dust cover gt 0 O 0 00 O O O O PGI MM PMS SY 09 10 N B 104 Infant Open Care System For Nicu Specification Microprocessor based servo control unit with integrated bed with radiant warming Integrated phototherapy lamps with quartz halogen lamp central Alarms for temperature etc Feather tough key pad Should have servo control for skin temperature control Should also have measurement for near to core temperature Thermoregulation Sensor accuracy
80. can be tilted along its horizontal axis Provided with an extra shelf underneath the baby s bed for placing oxygen cylinder infusion pumps drugs etc PGI MM PM SSY 09 10 N B 47 PGI MM PM SSY 09 10 N B 48 Table top autoclave for Operation Theatre e Multiple programmed for instruments textile liquids etc with pre and post vacuum dry cycle e Microprocessor controlled cycle time amp temperature e Microbiological in built air filter e Digital Display LED of Operations in sequence and temperature and timer cycle documentation through a printer serial port connection for PC USB storage unit Front loading with Deionizer for connection to water Chamber volume 20 25Ltrs Temperature control 121 C to 134 C Operating pressures 15 PSI to 30 PSI Class B sterilizer designed to meet EN 13060 The warranty of equipment will be five years AMC charges should also be offered e firms to give installation requirement for the equipment in their technical offer Fluid incubator for warming fluids in the operation theatre Specifications System natural convection Outer dimensions approximately 730Wx635Dx870H Capacity approximately 153 litres Exterior cabinet Baked on acrylic finish in galvanized steel Interior cabinet stainless steel Door baked on acrylic finish on galvanized steel Insulation material glass wool Inner door tempered steel Shelves stainless steel stainless wire Temperature con
81. ceps Medium size Suture Cutting Scissor Small Bowl Container for instruments PGI MM PM POWER DRILL FOR MAXILLOFACIAL AND SMALL BONE SURGERY SSY 09 10 N B 68 e Microprocessor controlled power Driver system should provide complete functions of bone harvesting drilling amp fixation of small bone amp helps in osteosynthesis e Should have computerised control with touch screen facility having options of digital display of speed amp to preselect acceleration amp beraking of handpiece speed e Should be provided with cable amp footswitch amp should be provided with complete set of following accessories e Universal Drill Multiple handpieces 1 5 speed upto 30 000 rpm e Micro Saggital Saw with blades with speed of 20000 cycles min e Micro Oscillating saw with blades with speed upto 15000 rpm e Micro reciprocating saw with blades with speed of 20000 cycle min e Wire driver with max peed 2500 RPM e Cutting burrs amp twist drill PGI MM PM TITANIUM OSTEOSYNTHESIS PLATING SYSTEM a P it should be a complete Titanium Implant System with Micro Mini amp Fracture plating of 1 2mm 2 0mm amp 2 3mm The plates and screws provided should be suitable for Reconstructive Hand amp Craniomaxillofacial Surgery The system should be supplied complete with the Container Racks and Instruments amp Implants Screws and plates should also be supplied on demand basis in Hospital HRF also at reasonable c
82. cified in this order The Equipment supplied shall carry a warranty of 60 months from the date of satisfactory Installation and commissioning of the equipment If any trouble or defect originating with the design materials workmanship or operating characteristics of any materials arise at any time from the date of Installation the same shall promptly as possible make such alteration repairs and replacement as soon as notified thereof the seller shall at his own expenses and as promptly as may be necessary to permit the materials function in accordance with the specification and to fulfill the foregoing guarantee warranty The Institute may at his option remove such defective materials at the seller s expense in which event the seller shall without any cost of the SGPGIMS and as promptly as possible furnish and install proper materis repaired or replaced materials shall be similarly guaranteed for a period of not less 30 thirty months from the date of shipment In the event that the materials supplied do not meet the specifications and are not in accordance with the drawings date sheets or the terms of this order rectification is required at site the SGPGIMS shall notify to the seller giving full details of differences The seller shall attend the site within seven days of receipt of such notice to meet an agree with representative of the SGPGIMS the action required to correct the deficiency If the seller fails to attend meeting at site within t
83. ction with the help of different dedicated softwares 7 Workstation should have the essential feature of Dynamic Auto focus 8 This workstation should use LASER as a source for excitation for analysis 9 System should have the capabilities to stabilize the LASER 10 Workstation should capable to analyze 48 arrays in one time with time of 8 min to 15 min 11 The system should have high throughput 48 position auto loading carousel with a capacity of 384 samples using a multiarray format 12 Software of this workstation should capable to analyze applications like Gene expressions Chip on chip for protein DNA interactions 13 Sensitivity should be at the level of 0 05 cpsm Chromophore per square micron or 5 molecules of dye per 10 micron pixel 14 The system should have capability for simultaneous and sequential scanning 15 The manufacturer should provide multi array format slide with own manufactured amp optimized chemistries 16 Workstation should be CFR11 compliance 17 System should be capable to do 5micron scan 18 Workstation should also come with hybridization Rotator chamber Washer 19 Workstation should also come with Electronic Array e array facility so that custom designing of array will be Free of cost 20 Work station should be an Open Platform so that any 1x 3 slides can be analyzed and open to any present and future applications 21 Supplier should have fully functional Genome wide Application Workstatio
84. ctronical transformer Power supply 110 220 V Bulb 12V 20W halogen light intensity approx 20 000 Lux at 40 cm Lamp should emit natural white light colour temperature 4000 K Reflector adjustable for positioning Free cord lenght approx 3 m To be supplied with 1 spare bulb and 1 spare fuse Examination light mobile 220 12V must be in conformity with Council Directive 93 42 EEC on medical devices and have a CE marking PGIMM PM OBSTETRICS DELIVERY TABLE Should have 3 sectional mattress base made up of epoxy d i 13 powder coated steel with large perineal cut Should have Hydraulic height adjustdment 550 920mm with pedals on both the sides Should have pneumatic adjustment for back section for Trendelenburg and reverse trendelunberg Should have support bar for additional support during forceps delivery Side rail with hand gripper or holder Should have a stainless steel basin which should slide on tracks Should have sliding foot section which can slide below the other part of the table Should have antistatic mattress 80mm thick Should have antistatic castors of diameter 150mm with central braking system and steering facilities for facilities for easy transfer patient Should be equipped with accessory rail for fixing various accessories Should be complete with side rails Infusion rod and adjustable leg supports Leg rest should be padded and adjustable to different heights and angle PGIMM PM DELIVERY BED d 14 Deliv
85. culum 80x35MM 150MM SIMS Bivalve Vaginal Speculum 90x40MM 175MM CUSCO STANDRAD BIVALVE VAGINAL SPECULUM SET OF 4 SEIDL VAGINAL SPECULUM SET 80X8MM 170MM SEIDL VAGINAL SPECULUM SET 80X10MM 170MM SEIDL VAGINAL SPECULUM SET 90X14MM 170MM KRISTELLER VAGINAL SPEC SET 70X15 MM IJN nm W BRAUN VAGINAL SPECULA 56X13MM BRAUN VAGINAL RETRACTOR 60X10MM ANTERIOR VAGINAL WALL RETRACTOR N DOYEN VAGINAL SPECULA 60X45MM DOYEN VAGINAL SPECULA 90X45MM HR RANDALL ENDO BIOPSY CURETTE 240MM Nn NOVAK SCHOECKAERT ENDO BIOPSY CURETTE 240MM SIMS UTERINE PROBE GRADUATED MALLEABLE ENDROMETRIAL BIOPSY CURETTE SMALL I oo SCHROEDER UTERINE SCOOP SHARP RIGID FAURE BIOPSY FORCEPS 210MM PLACENTA AND OVUM FORCEPS CURVED WITH SERRATED CUPS N UTERINE CURETTE DOUBLE ENDED BLUNT AND SHARP RIGID SHAFT 4 5MM N 22 UTERINE CURETTE BLUNT AND SHARP RIGID SHAFT 7 5MM 23 SHIRODHKAR UTERUS HOLDING FORCEPS 24 JOLLY SELF RETAINGING VAGINAL RETRACTOR 155MM 25 KELLY TISSUE GRASPING FORCEPS WITH RACHET 320MM 26 27 LANDON VAGINAL SPECULA 89x25MM 195MM JACOBS UTERINE TENACULUM FORCEPS 215MM 28 BRAUN TENACULUM FORCEPS 250MM STRAIGHT AND SLENDER 29 30 SCHROEDER TENACULUM FORCEPS 250 MM U
86. d commands 12 ECG triggered mode display of single beat with stable display 13 User programmable screen configuration 14 User programmable stimulation protocols 15 Real time beat by beat display 16 Continuous suface ECG visualization 17 Split screen display for template viewing amp matching PGI MM PM SSY 09 10 C 3 07 18 On line view of real time amp review data simultaneously 19 Selectable amount of data to be stored per patient 20 Computer based display of RF parameters 21 Adequet filtering 22 UUser configurable reporting format 23 Data transfer to power point JPEG or similar formats 24 Free of cost software upgrade 25 Single party supply of all components Specifications for lsocentric Brachytherapy Simulator 1 Description of Function 1 1 The therapy simulator serves the purpose of simulating verification and planning of brachytherapy amp teletherapy treatment 2 Operational Requirements 2 1 The simulator should be able to provide orthogonal and variable angle isocentric views films for brachytherapy planning of various sites and also teletherapy equipment cobalt amp linear accelerators The offered tabletop should be carbon fiber with indexing facilities replicating the existing treatment units in the department The unit should have at least four lasers one ceiling mounted two lasers mounted on the sidewalls and one more laser facing the gantry mounted on the wall The system should be c
87. d on F O B as well as estimated CIF New Delhi basis for imported goods Indian Agency commission rebate payable to Indian Agent if any shall be shown separately and that will be payable in equivalent rupee directly to Indian Agent as per declaration furnished by foreign suppliers The Institute reserves the right to get their goods air freighted Sea freighted amp air insured marine insured up to site The offer of the tenders shall remain valid for a period of 180 days from the date of opening of the tender All goods or materials shall be supplied by the tenderers whose tender is accepted strictly in accordance with the specifications drawings data sheets other attachments and conditions stated Any alterations of those conditions shall not be made without the consent of the Institute in writing which must be obtained before any work against the order is commenced All material furnished by the seller pursuant to this order irrespective of whether engineering design data or other information has been furnished reviewed or approved by the Institute will be guaranteed to the best quality of their respective kind unless otherwise specifically authorized in writing by the Institute and shall be free from faulty design to the extend such design is not furnished to the Institute workmanship and materials and to be of sufficient size and capacity and of proper materials so as to fulfill in all respects with all operating conditions if any spe
88. d on acrylic finish on galvanized steel 9 Warranty 5 years PGI MM PM SSY 09 A 40 deg C Deep Freezer 10 N B 84 Ultra low temperature freezer upright type made of sturdy galvanized material and internal casing of SS with operating temperature of 10 C to 40 C at ambient temperature of up to 35 C approx 380 to 400 L capacity not less than 350 L CFC HCFC HFC refrigerant free air cooled hermetic compressors with dual condenser fans mounted on 4 castors Micropressor controlled with touch pad data entry and digital display of all functions key operated main switch battery powered independent operating temperature and high low limit alarm functions for high low temp 10 K to set temperature automatic voltage boost to compensate for low voltage onboard power monitoring with display of incoming voltage Heated door sealing sturdy inner doors and minimum of 4 independent inner compartments high density door insulation door provision for padlock Compressor warranty of 5 years Optional Provision for vaccum release assembly for rapid opening of door for re entry racks boxes of different sizes and dividers for half the freezer 230V AC 50 Hz cycle B 80 C Deep Freezer Ultra low temperature freezer upright type made of sturdy galvanized material and internal casing of SS with operating temperature of 5 C to 86 C at ambient temperature of up to 35 C approx 380 to 400 L capacity not less than 350 L C
89. e clip applicator for Titanium clips Diameter 10mm for Medium large clips Single clip applicator for Titanium clips Diameter 10mm for Medium clips Pylorotome Size 3 mm length 20 cm Pyloric muscle spreader Size 3 mm length 20 cms Bipolar cautery forceps 5mm Bipolar Fenestrated Forceps with Spring Handle 5mm Bipolar Micro Tip Forceps with Spring Handle Light source Xenon Cold light fountain one 175 180 Watt XENON lamp Fibre optic light cable length 250 cm heat resistant Endoflator Electronic endoflator adjustable flow rates of 0 20 litres min pressure range 0 30mm Hg pressure reducer valve Provided with silicon autoclavable tubing with luer attachment Suction irrigation system consisting of suction irrigation handle sealing cap for irrigation amp suction handle sealing attachment with opening amp membrane valve for auxillary instruments upto 5 mm suction irrigation tube length approx 310 mm diameter 3 5mm 5 0mm Mobile video trolley including at least 4 shelves 4 anti static castor wheels camera head holder infusion bottle holder CO2 cylinder holder integrated cable ducts PGI MM PM SSY 09 10 N B 37 Pediatric cystoscope resectoscope set Specification 1 Telescopes Miniature compact fibre cysto urethroscope 4 5 6 Fr For neonates and children Miniature 0 degree fibre telescope 2 4 Fr instrument channel Straight forward telescope 0 degree diameter 1 2 mm wor
90. e plate straight 0 55mm profile 4 hole plate with gap straight 0 55mm profile 16 hole plate straight 0 55mm profile L plate 6 hole Right oblique L plate 6 hole Left oblique T plate 6 holes Rt oblique T plate 6 holes Lt oblique 2x2 2 hole 4x2 replent plate Titanium Screws cross lock 1 7 x 6mm Titanium Screws cross lock 1 7 x 8mm Titanium Screws cross lock 1 7 x 11mm Titanium Screws cross lock 1 9 x5mm Titanium Screws cross lock 1 9 x7mm MINI SYSTEM 2 0 INSTRUMENT FOR TITANIUM IMPLANT SET Container 300 x 300 x 150mm Instrument Rack Teflon Implant Tray Plate Bending Plier with pin 13 5 cm Flat plier 13 5cm Plate cutting plier 18cm Plate cutting scissors TC 12cm Plate amp screw holding forceps angled Screw driver with gripping device 18cm for single slot screws Screw driver handle none rotatable for all blades Spare blade cross lock press fit Spare blade squre lock press fit Twist drill 1 5 x 50mm for screws up to 7mm length Twist drill 1 5 x 50mm for screws up to 20mm length Twist drill 1 5 x 70mm for screws up to 7mm length Twist drill 1 5 x 105mm for screws up to 20mm length TITANIUM IMPLANT SET PLATE amp SCREW 2 0 TITANIUM FLAT LINE PLATE 4 Hole Plate without stem 0 6mm profile 4 Hole Plate short stem 0 6mm profile 4 Hole Plate long stem 0 6mm profile 6 Hole Plate without stem 0 6mm profile 8 Hole Plate without stem 0 6mm profile L plate 4 Holes rig
91. emp 6000 Kelvin 10 80 mm variable spot at a working distance of 40 cm Operating Voltage 200 240VAC 50 60 Hz includes Head band Light weight Bi furcated cable approx 9ft joy stick PGI MM PM SSY 09 10 N B 54 Volumetric Infusion Pump Specification Ambient temptreture 50 400 C Power supply AC 220 V 50Hz Operating principle Linear Peristalsis Infused display 1 9999 ml Flow option 10 3000 ml hr Time limition option 1 min 24 hrs Infusion accuracy Error not more than 1096 for a range of 10 3000 ml hr Alarms Infusion completion Bubble Block Open door Low battery Battery backup 4 6 hrs Mountable on standard IV stand low weight machine preferable Adaptable to generic IV sets used for all IV fluids and TPN high osmolar fluid Pediatric utility PGI MM PM SSY 09 10 N B 55 Sleep Laboratory Specification 1 Capability to records both AC and DC signals 2 Facility to record the following patient parameters e Heart rate ECG Bipolar EEG with atleast 4 channels EOG with separate tracing for each eye EMG Thoracic and abdominal respiratory effort Intensity of snoring sound Body position Limb movement Oxygen saturation by finger oximetry Nasal oral airflow e Nasal pressure e CPAP pressure 3 At least six spare DC channels 4 Two sets each of all necessary sensors electrodes and leads 5 Compatible reader for flash or other media used for data storage 6 Compatible software for data acquisition real time gr
92. er Point 50 VA Nominal Current 220mA Power Line isolation 0 315 AT 10 Indian Make Pressurizing Module 1 No Pressurizing Module is used to Create the positive pressure inside culture lab Tech specification Pressure 250 CFM Filtration 0 3u Efficiency 99 97 Construction Stainless Steel body 11 Petri Plate Prewarmer with Steel Body for preheating of slides 1 No petridishes pipettes etc of desired temp anodized aluminium heating plate Approx dimension 300X100X40mm Temp range from ambient to 110 C with accuracy of 0 2 C 12 Microscope Stage Warmer with Steel Body for maintaining the 1 No temp of critical biological specimens at desired level during microscopic observation An anodized plate of 10mm thickness with 50mm central grove with glass amp 175X155mm dimension which should fit on most microscopic stages Temp Range ambient to 55 C with accuracy of 0 2 C 13 CODA Portable Air Purification unit Max Air Flow 530 CFM Effective coverage up to 350 sq feet Application more than 2000 sq feet No 14 Cryopreservation Equipment portable capable of taking at least 40 embryos Controlled Rate Preprogrammed Freezer for Freezing Sperms Oocytes Embryos complete with Preprogrammed Controller Standard Cryochamber for Vertical Freezing LN2 bath Capacity maximum 2L Software for making new programs for future user SPECIFICATIONS Temperature Controller Con
93. ery Bed suitable for deliveries in Sitting and Supine position Should have 3 sectional mattress base Seat section should have a large perenial cut out and should be made up of durable ABS Plastic for easy cleaning Should have a retractable Foot Section made up of ABS Plastic for converting bed to chair Should have Hydraulic Height Adjustment 530 900 mm with pedals on both the sides Should have pneumatic stepless adjustment for back section such as Trendelenburg and reverse trendelenburg position It should have a separate back section control lever for mother Should have adjustable foot supports Should have support bar for additional support during forceps delivery Should have a detachable head board to provide access during resuscitation procedures Should have a stainless steel basin which could be pushed under the base Should have antistatic castors of diameter 125 mm with central braking and steering facilities for easy patient transfer Should be supplied complete with antistatic mattress 80mm thick side rails with push grip PGI MM PM SSY 09 10 N B 15 handles and adjustable leg supports Mobile Halogen Light DELIVERY ROOM LIGHT To be used in delivery rooms and minor procedure room Should offer light intensity 1 00 000 lux or more Should have three halogen bulbs with infrared coating and ceramic base for providing cool light The heat increase at the surgeon s head should not be m
94. ery LCD 125 x 64 ors STN LCD Distterry Ve Approx 2 5 haurs Viavstorm Nurrarical data amp Heart Automatic shut off Outputs Haardset Speaker cut ot Speaker output 20D mi or more Serial port HS 232C Vulb irsquanzy 4 5 8 10 MHz Dimensions Waveform memory 30 wevstorms Weight 350 grams including batery and pr Mode settings Memory store read amp clear Direction Electrical galety Conform te IEC 80601 7 Scales lime unil Language elc PGIMM PM BASIC PLASTIC SURGERY SET Pd rm This will include general plastic surgery instruments and instruments for specialized surgery 1 General Instrument Set Quantity required 2 Total cost of 2 sets Rs 10 00 000 00 GENERAL INSTRUMENTS MAIER POLYPUS FORCEPS WITH RATCHET CVD BACKHAUS TOWEL HOLDING FORCEPS 110MM TOWEL CLAMP 115 MM LENGTH SCALPEL HANDLE NO 3 IRIS AND LIGATURE SCISSORS STR 110 MM KILNER DISSECTING SCISSORS 150 MM REYNOLDS SCISSORS CVD 175 MM DISSECT SCISS METZENBAUM 145MM CVD DURO DISSECT SCISS METZENBAUM 180 CVD DUROTP DUROTIP LIGATURE SCISSORS 180MM LONG DUROTIP DISS SCISS MAYO LEXER CVD 165MM OP SCISSORS STR BL SH 145 MM S DISSECTING FORCEPS SLEND PATT 145 MM ADSON FORCEPS FINE SERRATED JAWS 120MM ADSON FORCEPS 1X2 TEETH 120 MM NON TRAUMATIC VESSEL FORCEPS 150 MM TISSUE FORCEPS AM PATT 1X2 T 145MM BABY MOSQUITO ARTERY FORCEPS CVD 100MM MICRO HALSTED HEMOST FORC CVD 125 MM PGI MM PM SSY 09 10 N B 63
95. escopes in section A 2 Insulated biopsy forceps with handle one 3 Insulated grasping forceps with handles two 4 Insulated straight cutting scissors with handle one 5 Insulated curved cutting scissors with handle one 6 Injection cannula one 7 Palpation probe one 8 Insulated suction tubes with valves two 9 Tissue retracter one 10 Pleural abrader one 11 Straight needle holder one 12 Curved needle holder one 13 Surgical knot pusher one 14 Insulated coagulating electrode with its high frequency cord one 15 Mobile trolley compatible with the whole system one 16 All necessary adapters connectors and cables 17 All metallic instruments and accessories should be reusable and autoclavable C Light source 1 Xenon light source atleast 175 Watt with fibreoptic light cable one 2 Extra spare xenon bulb for use with this light source one D Video system 1 Endoscopic camera CCD with minimum zoom range 21 36 2 Colour monitor with minimum 14 inches screen 3 Facility for digital storage of images on removable media either CD or flash media E Power 220 V 50 Hz AC F Warranty for five years AMC CMC for five years Individual price for all item nos 1 to 14 under section B and nos 1 to 2 under Section C should be quoted separately PGIMM PM NERVE STIMULATOR SSY 09 EE Er TUN B 59 Specifications Should Have e RECHARGEABLE ACCUMULATOR e BUI
96. esign to put the centre of gravity between webspace amp index finger Instruments should be curved to facilitate needle driving The micro scissors should be specially designed for minimum closing pressure and for equal pressure distribution along the blades Handles should be round with spring instrument configuration amp with curved blades They should be rounded at the tips with radius of 0 2mm amp adventitia scissors should have very sharp tips that are pointed for fine trimming amp suture cutting All instruments should have special ergonomic design amp have well made tips for high durability The vessel dilator should have special ball point form of the tips so that the dilating pressure Is evenly distributed over the entire area of the vessel Needle holder should be specially designed for secure grip due to parallel closure over the entire jaw length and closing pressure precisely calibrated for minimising fatigue They should have stronger tips to withstand higher pressure tip dia 0 3mm or 0 4mm Micro clamps should be light compact robust corrosion resistant amp have unique gripping surface They should have smooth sliding bar action on all approximator clamps for vessel diameter of 0 4mm to 5 0mm pressure of 5 gm mm2 to 15gm mm2 Forceps 15cm round handle 8mm dia st Forceps 15cm round handle 8mm dia cvd tip Forceps 15 cm long round handle 8mm dia angulated 45 dig Forceps 11cm long flat handle 9mm wide st
97. event of delay delivery and or unsatisfactory manufacturing progress and supply the SGPGIMS has the right to cancel the purchase order as whole or in part without liability of cancellation charges In the event of rejection of non confirming goods the vendor shall be allowed without any extension of delivery time to correct the non conformities should however the vendor fail to do so within stipulated time the SGPGIMS may cancel the order No payment shall be made for rejected material nor would the tenderer be entitled to claim for such items Rejected items would be removed by the tenderer from the site within two weeks of the date of rejection at their own cost In case they are not removed they will be auctioned at the risk and responsibilities of the suppliers without any further notice In the case of not honoring the supply order Sanjay Gandhi Postgraduate Institute of Medical Sciences will have the right to impose penalty as deemed fit to resort to make purchase at the suppliers cost and risk may forfeit his security to make purchase at the suppliers cost and risk In the case of non supply of stores within stipulated period it will be at the desecration of the Sanjay Gandhi Postgraduate Institute of Medical Sciences to accept delivery with late delivery clause 196 per week maximum to the extent of 10 of the ordered value for delayed supply In the case of imported goods the late delivery clause will be imposed 0 5 per week subject to t
98. f the FOB Rupees value of all the local items if any with annual inflation in the range of 8 to 10 of the original CMC value All the items including local items and consumables for functioning the equipment needs to be included in the CMC and no exclusion criteria will be accepted The batteries of the UPS will be included in the above CMC quote GENERAL CONDITIONS 1 Model offered should the latest and spare parts and service support for 10 years from the date of installation 2 The supplier shall quote for the most recent model of their machine If 95 uptime is not maintained penalty clause of Rs 5 000 per day will be charged All service calls should be attended within 24 Hours of receipt of Fax message The firm should commit to place a properly factory trained service engineer locally for providing up time of 95 as per standard international norms 3 Declare separately the FOB CIF and Indian agency commission if applicable The lowest bidder L1 will be identified by adding up the CIF prices local items in Indian rupees if any turnkey Cost of the CMC with taxes if applicable for the next five years after the warranty period i e items covered under 1 7 3 above excluding 4 3 CBCT The optional item 4 3 Cone Beam Computed Tomography is to be quoted on separate sealed envelope with prices valid for 1 year after installation for subsequent purchase if the Institute desires and this will not be included in the L1 compa
99. f the parties there under or as to any clause or thing herein contained or by reason of the supply or failure or refusal to supply any material or as to any other matter in any way relating to these presents shall be referred to the sole Arbitration President of the Institute Chief Secretary of the U P Govt or his nominee The decision of the sole arbitrator shall be final and binding upon both parties and subject to adjudication of Lucknow Court Place for arbitration shall be at Lucknow U P India Venue of such arbitration proceedings shall be the Institute Arbitration and conciliation Act 1996 and rules made there under shall be applied to the proceedings under this clause Sales Tax Registration certificate duly attested copy by a Gazzetted Officer should also be enclosed Sales Tax Income Tax clearance certificate along with the affidavit from a notary that the firm has never been black listed must be attached along with the tender failing which the tender will be rejected and no correspondence will be entrained in this regard Tenderers hereby agree to all terms and conditions stipulated in N I T and undertake to sign the rate Contract or Supply order within the given days from the date of order failing which Security shall be liable to forfeit The manufacturer or their Indian representative will ensure a proper after sales service as per our requirement from time to time against the guarantee warrantee clause as per the terms and condition
100. fying Loupe 4 5 X Loupes with Head Band 2 5 X Loupes with Head Band e loupe should be light weight with adjustable working distance POWER ASSISTED LIPOSUCTION SET Aspiration should operate as stand alone aspirator unit amp to power a variety of pneumatic infiltration devices for tumescence infiltration amp Power assisted suction lipectomy It should be able to power additional modalities including the infiltration system power reciprocating cannualle and infusion pumps Should be operable on two positive displacement pump which should be dual headed to relieve back pressure allowing each pump to pull directly against the patient so that a deep vacuum is quickly reached amp maintained The two pumps should be able to continue functioning independent of each other The pumps should be mounted on shock absorbers to eliminate vibrations Should have a shock proof muffler amp insulation system Should be able to operate both through hand amp foot pedal The machine should operate on 220 volt A c mains Should be provided with aspiration kit including the tubing 8ft long 3 8 ID Canisters along with filter connection The Kit should be provided with Implosion proof high impact canisters provided with disposable liner amp absolute micro fibered filters for efficiency of 0 3 microns particle size Should have facility for temporary replacement by a same or lower model machine and accessories during re
101. g wavelength maxima Integral erbium calibration reference Ensures wavelength accuracy Software Data System Package HPLC System to include USB I F Board and following function Should have simultaneous display of a contour map 3 D display chromatogram and spectrum in a single window Display of information on one screen allows easy confirmation of the spectrum of the target peak Multi chromatogram Information about the entire wavelength range can be obtained with one measurement permitting extraction of an arbitrary number of chromatograms of any wavelength in 1 nm increments The chromatogram can be used for on line quantitative calculation Peak purity calculation function The peak purity should be displayed in the form of correlation coefficients enabling easy comparison between samples Use of similarity curves shows the location of impurities at the peak which is effective in examining the purity in detail Spectral library search function A spectrum that resembles the spectrum of the target peak is automatically searched Spectra are displayed in the descending order of similarity which is effective for discriminating unknown peaks This function permits recalculation as well as searching during data collection to improve efficiency of analysis Note The system should be provided with following accessories form Indian Market 1 Suitable PC and printer 2 Rheodyne injector 3 251 syringe 4 C 18 column 5 250 x
102. h Accessories Workstation Standard Electrically Heated Laminar Flow Cabinet 1246x735x2015mm WxDxH 1 Stainless steel table plate 1 Liquid based heating system with heating area 1 Gassing system I Transmitted light opening I Preparation for Microscope light base 1 Light Source Microscope light source base Plain Mirror 360 degrees tilt ability 1 Hollow frosted 360 degrees tilt ability I 011171 Standard Accessories Warming Block for 7 follicular fluid tubes Warming block for 2 centrifuge tubes 16 5mm Warming Block for one Falcon 1006 ICSI Dish Warming Block for one 60mm dish Warming Block for one 4 well dish Glass Incubator hood 1 Glass Incubator Hood 1 Steel Incubator Hood 1 8 Stereozoom Microscope I No SMZ Zooming Body Standard binocular eyepiece tube which can be inclined 20 for observation in a natural posture with a straight back Facility of ergonomic objectives Eyepiece 10 x With diopter adjuster rubber eye shield reticle lead Diascopic Stand Transmitted Light Illuminator with reflecting mirror supplied with transparent stage glass 6V 20W Halogen lamp with reflector 9 Ovum Aspiration Pump with Foot Operated Switch with 1 No Vacuum gauge and regulator Specifications Low Pressure 0 550mm Hg Volume of overflow vessel 2x100ml Connecting for aspiration tubing 2 to 4 mm Power Supply 230V Power Frequency 50 60 Hz Pow
103. have copper internal pipes for long life amp rust prevention Internal pipes should be chemically or thermostatically disinfected Should have integrated advanced Hydrosound ultrasound generated bubbles system with timer amp intensity control for gentle message amp removing dirt particles amp dressing from patients skin e Should be supplied complete with battery operated Lift bath trolley e Should have powered raising lowering and adjustment for back e Should have integrated electronic patient weighing scale Should be suitable for patient pick up from either side of the bed Should have single piece moulded stretcher made of Poly Urethane easy to clean amp disinfect with adjustable head pillow amp thigh support cushion Should be supplied with security grip side guard amp battery charger Should have central braking system controlled by waterproof handset or operator panel on pillar Should have minimum Patient Lifting capacity of 160 Kgs Length 1950mm Width 850mm The complete system should meets international quality and patient safety standards like CE TUV ISO 9001 BS 5750 EN 29001 PGI MM PMS SY 09 10 N B 108 Specifications For Patient Hoist With Integrated Weighting Scale Should be easy to assemble and disassemble for easy storage and transportation Should have integrated weighing scale Should have battery detachable to operate the lift with audio and visual alarm for battery status Should ha
104. he maximum of 5 of FOB value In the case of not honoring the supply order Sanjay Gandhi Postgraduate Institute of Medical Sciences will have the right to impose penalty as deemed fit to resort to make purchase at the suppliers cost and risk may forfeit his security to make purchase at the suppliers cost and risk SANJAY GANDHI POST GRADUATE INSTITUTE OF MEDICAL SCIENCES RAEBARELI 43 44 45 46 47 48 49 ROAD LUCKNOW 226 014 TENDER DOCUMENTS GENERAL TERMS amp CONDITIONS FOR NOTICE INVITING In the case of not honoring the supply order Sanjay Gandhi Postgraduate Institute of Medical Sciences will have the right to impose penalty as deemed fit to resort to make purchase at the suppliers cost and risk may forfeit his security to make purchase at the suppliers cost and risk In the case of non supply of stores within stipulated period it will be at the desecration of the Sanjay Gandhi Postgraduate Institute of Medical Sciences to accept delivery with late delivery clause 1 per week maximum to the extent of 10 of the ordered value for delayed supply In the case of imported goods the late delivery clause will be imported 0 5 per week subject to the maximum of 5 of FOB value All disputes and question if any arise between the Institute and the bidder out of or in connection with the terms and conditions contained herein or as to the construction of application thereof or the respective rights and obligations o
105. he time prescribed above the SGPGIMS shall immediately get the same rectified the work materials and seller shall reimburse the Institute all costs and expenses incurred by the SGPGIMS in removing such trouble or defect 100 payments shall be released within 30 days from the date of satisfactory receipt of materials or satisfactory installation if applicable Where necessary performance bank guarantee 15 of the ordered value or FOB value shall be submitted to the Institute before arranging the delivery till expiry of warranty period In the event that the materials supplied do not meet the specifications and are not in accordance with the drawings date sheets or the terms of this order rectification is required at site the SGPGIMS shall notify to the seller giving full details of differences The seller shall attend the site within seven days of receipt of such notice to meet an agree with representative of the SGPGIMS the action required to correct the deficiency SANJAY GANDHI POST GRADUATE INSTITUTE OF MEDICAL SCIENCES RAEBARELY ROAD 31 32 33 34 35 36 37 38 39 40 41 42 LUCKNOW 226 014 TENDER DOCUMENTS GENERAL TERMS amp CONDITIONS FOR NOTICE INVITING In the event that the materials supplied do not meet the specifications and are not in accordance with the drawings date sheets or the terms of this order rectification is required at site the SGPGIMS shall notify to the seller giving full de
106. ht without stem 0 6mm T plate 6 Holes without stem 0 6mm profile Y plate 5 Holes without stem 0 6mm profile Orbital plate 6 Holes curved 0 6mm profile TITANIUM SCREWS FLAT LINE Single Slot Screws 2 0x 5mm Screws 2 0x 7mm Screws 2 0x 9mm Screws 2 0x 11mm Screws 2 3x 5mm Screws 2 3x 7mm TITANIUM FRACTURE SYSTEM 2 3 INSTRUMENT FOR FRACTURE SYSTEM Container 300 x 300 x 150mm Instrument Rack Teflon Implant Tray Plate Bending Plier 13cm Plate and screw holding forceps angled Tuffno Screwdriver Handle only for all blades Spare blade hexagon lock press fit Twist drill 1 8 x 98mm ON Q IMPLANT TITANIUM PLATES PROFILE HEIGHT 1 5mm 4 Hole Plate short stem 4 Hole Plate medium stem 6 Hole Plate short stem 6 Hole Plate medium stem 8 Hole Plate medium stem 14 Hole Plate without stem 4 Hole Plate C shape medium stem Mandibular angle Plate 6 Hole 4 Hole Plate for alveolar compression short stem 4 Hole Plate for alveolar compression medium stem TITANIUM SCREWS 2 3 mm Hexagon lock 1 Screws 2 3 x 8mm 2 Screws 2 3 x 10mm 3 Screws 2 3 x 12mm PGI MM PM SSY 09 10 N B 97 SEQUENTIAL COMPRESSION DEVICE FOR LYMPHEDEMA Should be a sequential compression Device for providing graduated sequential compression and rapid impulse inflation to Calf foot amp thigh It should have sequential pulse frequency with choice of
107. ic lung volumes airway resistance lung compliance Intercom for communication with patient ladd Capability to measure pulmonary diffusion capacity using single breath technique Capability to measure static lung volumes using helium dilution technique Pneumotach system for flow measurement 9 Online helium carbon monoxide and oxygen analyzers 10 Fully computerized calibration procedure foe flow sensors and gas analyzers 11 Carbon monoxide analyzer range 0 0 4 accuracy 0 0003 12 Helium analyzer range 0 9 5 accuracy 0 05 13 Two cylinders each of helium and diffusion gas mixtures EAN 14 Windows XP compatible diagnostic software 15 Pentium IV computer with 2 8 GHz processor or better at least 100 GB hard disk at least one GB DDRAM CD and DVD writer 3 5 floppy drive keyboard optical mouse 17 monitor RS232 port atleast six USB PGI MM PM SSY 09 10 N B 58 2 0 ports preloaded Windows XP Professional online UPS 16 Colour inkjet printer 17 All necessary catheters cables adapters software CDs and manuals 18 Power 220 V 50 Hz AC 19 Warranty for five years 20 AMC CMC for five years after expiry of warranty Thoracoscopy System Specification A Two forward viewing rigid telescopes with instrument channel and fibreoptic light transmission and diameters 7 8 mm one and 9 10 mm one B Essential accessories l Metal trocars and cannula two one each compatible with the two tel
108. ile grade cell sorting with no effect on cell viability 4 Portable sorter compatible to be placed in laminar flow hood 5 High cell sorting capacity ranging from 0 5 x 10 to 5x 10 per run 6 Should have positive and negative selection systems of sorting applicable simultaneously 7 Compatibility for sorting of 7 haematopoietic and CD34 non haematopoietic cells 8 The system should be capable of sorting at least two sample simultaneously 9 Flexibility to meet multiple immuno selection per rum 10 The system should have data storage device and up gradable software and procedures 11 Should be a user friendly system with low running and maintenance cost 12 Power Supply AC 100 240 V 50 60 Hz PGIMM PM Flexible Ureteroscope SSY 09 10 C 1 121 Specification Instrument channel Stone holding flexible forceps Flexible biopsy forceps PGIMM PM Automated Immunostainer SSY 09 10 C 2 20 Open optimum protocol flexible system Capability to accommodate multiple protocols Priority slide handling dedicated desktop computer Ease to use with concentrated amp pre diluted ready to use primary antibodies and different visualization systems Start and finish runtime display with delayed start option Slide labeling system Seperate waste container with non spillage Immunostaining of formalin fixed paraffin embedded tissue frozen seelion cytospins cell smears and fine needle aspirates
109. image manipulation options including optimized view inverse view full screen view zoom pan multiple view 2 4 9 images revert to previous original image 8 Workstation lay out with 4 data fields parameter overview Annotation tools length and angle measurements Contouring tools 9 Digital MLC shaping and verification with drag and drop MLC leaf positioning adjustment Blocking Trace function for dual image contour comparison of saved or imported images For convenience of external beam treatment the workstation should have planning software for beam placement shaping and treatment time calculation for units such as cobalt and Linac with compatibility of irregular planning and calculation of dose at any point within the prescribed field MLC overlay and export of plan directly to be transferred to the Linear Accelerator unit and integrated in the record and verify system 10 Anti Collision software Extensive and advanced collision avoidance software creates a virtual protective shell around the patient and machine parts which initiates an automatic slow down and movement stop if collision threatens 11 The detector automatically moves away to prevent collision with the patient table floor or ceiling during movement of the gantry and table Mechanical touch guards for back up safety are fitted on the gantry head and the detector 12 An override for individual parameters allows a maximum range of movements 4 System Configuration Accessories
110. ime traces on computer screen 7 Overlaying of previous test curves for comparison 8 Capability to store pre and post bronchodilator measurements in the same record 9 Capability to store atleast 500 patient test results 10 Capability to select and modify prediction equations 11 Automatic diagnosis facility 12 Facility for report generation through an external printer 13 Customizable report printout format 14 50 reusable mouthpieces 15 10 Noseclips 16 10 spare air filters 17 Facility for external calibration using a large volume syringe or similar method 18 All necessary adapters tubings calibration syringes cables software CDs manuals 19 Power 2020 V 50 Hz AC 20 Capability to work on rechargeable NIMH or Li ion batteries battery charger to be provided 21 Pentium IV computer with 2 8 GHz processor or better at least 100 GB hard disk at least one GB DDRAM CD and DVD writer 3 5 floppy drive keyboard optical mouse 17 monitor RS232 port atleast six USB 2 0 ports preloaded Windows XP Professional online UPS 22 Two year warranty 23 AMC CMC rates to be quoted for five years after expiry of five years warranty EN Body Plethysmograph system and Pulmonary Diffusion system JO B 57 Specification 1 Airtight transparent box of atleast 700 litre volume Data collection flow volume mouth pressure box pressure Facility for calibration using large volume syringe Measurements spirometry flow volume loops stat
111. ing depth must be available up to 30 cm or more e System should support broad band wide band Transducer Technology System should have Linear Array Curved Array Phased Array Multiplane TEE transducer attach detail of all the transducer e System must have frequency range from I 12 MHz 1 MHz e Imaging modes of Real time 2D Colour Doppler Pulsed wave Doppler Continuous wave Doppler PW TDI Power energy Doppler should be available e Controls for 2D mode Total gain depth dynamic range auto gain e System must have fast start up to scanning in less than 30 seconds as essential in critical and emergency situation in ICU emergency OT e Unit must be sturdy resistant to breakage amp damage on fall hit against the wall or hard surface e Cine memory on all modes e System should be DICOM ready system with print save modality worklist Ready to connect to PACS e Inbuilt Flat LCD TFT monitor of 10 or more e Alphanumeric soft keys keyboard with easy access scans controls system must have sealed keyboard for sanitization This must be possible to avoid cross contamination e Onboard storage of at least 10000 images e USB port for connectivity to computer e System should have extensive calculation package for cardiac Ob Gyn Vascular measurement and calculation provision for distance area volume and circumference e Must be able to operate both on AC and inbuilt battery Inbuilt battery pack should be self
112. ing heat storage capacity should be minimum fo 1900000 HU Image Intensifier Tv System The system should have a 12 trimode image intensifier The system should have high resolution 1 1 and please mentioned the 1 1 resolution The system shall be equipped with a high resolution CCD camera coupled with a lens for better image quality The camera gain and iris collimator should be computer controlled The system should be equipped with two high resolution 18 LCD TFT monitors The system should provide a last image hold capability so that the last image is displayed on the active monitor after termination on an exposure The system should be equipped with back lit X Ray control panel The system shall allow the use to change the image orientation on the display screen during a live exposure or using the last image hold Those functions include image rotation left to right and top to bottom image reversals Digital System amp Image Management The system should have multi patient date base for handling large quantities of image include dose management report The system should automatically select proper imaging parameters kVp and mA during an imaging but also provide the user to over ride these setting manually Real time and automatic brightness and contrast should be provided to optimize displayed image The system should provide a real time post processing edge enhancement capabilities to get better image quality according to
113. inimum bulb life of 2500 working hours Fiberoptic cables Atleast 5mm diameter over 6 5 feet length Monitor 26 one each flat panel custom designed with the colour depth amp enhancement requirements High resolution appropriate to the offered camera system SXGA technology 1280 X 1024 Capable of displaying SVHS VHS XGA amp DVI signals Carbon Dioxide Insufflator Preferably gt 12 litres high flow Insufflator wiyh heating Touch sreen controls Telescope 10 mm 30 degree amp 0 degree autoclavable laparoscope 05 mm 30degree Video recorder digital video recorder 2 Operating Instruments Veeres Needle 6 long Trocars pyramidal tip 5 5mm amp 11mm cannula 11mm 5 5mm automatic valve stop cock without trocar Reducers 10 5 5mm instruments 33cm PEEK monopolar handle Maryland dissector Nontooth grasper with spoon DeBakey grasper Aspiration needle 5mm PCOD needle scissors Metzenbaun scissors 5 mm 10mm straight amp curved atraumatic double action grasper 5mm myoma screw Curved left needle holder Curved rightle holder 5mm bipolar fenestrated forceps with spring handle 5mm bipolar microtip forceps with spring handle Suction irrigation canula 5mm amp 10 mm Suction irrigation machine Knot pusher Sterilizating tray for instruments sterilization Trolley for equipments Uterine manipulators PGI MM PMS SY 09 10 N B 111 Hysteroscopic Equipments 4mm o degree autoclavable hysteroscope 4mm hyste
114. izer Specification SSY 09 10 N B 91 Rotor and stator quick coupling autoclavable easily cleanable and resistant to routine lab disinfectants Electronic speed regulation of rotor continuously variable from 5000 to 30 000 rpm minimum or higher Motor power range 250 to 300 W Easy clean interchangeable dispersing aggregates with volume range from 0 5 to 250 ml 2 or 3 Nos depending upon the volume of the dispersing aggregates Integrated control knob and speed scale Plate stand vessel holder with head for hand free working Safety positioning ring PGI MM PM Specifications Of Microarray System Ad poem Specs for Microarray Workstation 1 Whole workstation should be capable to do microfluidics based electrophoresis system as quality control for DNA RNA and Protein as well as cell analysis 2 System should capable to give RIN RNA Integrity number for assessment of small RNA and total RNA for further microarray and real time PCR analysis 3 System should provide resolution up to 5bp and should also be capable of analyzing RNA in pico gram levels 4 Should come with dedicated software data analysis software algorithm dedicated for above mentioned applications 5 This system should go in tandem with Microarray system 6 Workstation should be capable to do applications like Micro RNA Comparative Genomic Hybridization DNA Methylation studies Splice variants Gene expressions Chip on chip for protein DNA intera
115. king length 20 cms autoclavable fibreoptic light transmission incorporated Straight forward telescope 0 degree diameter 1 9 mm autoclavable fibre optic light transmission incorporated Forward oblique telescope 30 degree diameter 1 9 mm autoclavable fibre optic light transmission incorporated Straight forward telescope 0 degree 1 9 2 1 mm autoclavable fibre optic light transmission incorporated Forward oblique telescope 30 degree 1 9 2 1 mm autoclavable fibre optic light transmission incorporated 1 Cystoscopes Cystoscope urethroscope sheath for examination and irrigation 7 fr Or 7 5 Fr With obturator and 2 LUER lock adaptors Working channel for accessory instruments upto 4 Fr Cystoscope urethroscope sheath 8 fr Or 8 5 fr with instrument channel 4 fr with obturator and 2 LUER lock adaptors Resectoscopes Resectoscope sheath 9 Fr With obturator with LUER Lock stop cock with the following Working element set with working element cutting loop coagulating electrode high frequency cord amp protection tube Telescope bridge with one instrument channel Resectoscope sheath 11 Fr With obturator with LUER Lock stop cock with the following Working element with cutting loop coagulating electrode Telescope bridge with one instrument channel Cutting loop angled Coagulating electrode angled blunt Coagulating electrode hook shaped ball end 1 Monopolar high frequency cord 2 Grasping forceps 5
116. lay The system should have a non interlaced high resolution Monitor with tilt and swivel facility The system should have Integrated recording keys for remote control storage and printing PGI MM PM SSY 09 10 N B 21 options e system should have more than 8000 digital processing channels Higher channels is desirable Please mention the number of processing channels e The system should have Windows Operating System Please specify the operating system used in the machine e system should have minimum 80 user defined preset per tranducer More presets is desirable e system should have advanced calculation package for all mentioned application Obstetrics gynaecological transvaginal small parts doppler and cardiac adult and pediatric e All transducers should have tissue harmonics imaging as standard The system should have Real time triplex imaging with Real time compounding with Color doppler mode on all transducers The system should have Panaromic View imaging The system should have trapezoidal imaging for all linear probes The system should have Volume 3d and 4d Imaging The system should have one touch optimisation function for adjusting doppler function while doing doppler scans e System should have post processing facility on Freez and Pulse and continuous wave doppler imaging e System should have facility for multiple frequency selection for fat patients preferably at one touch
117. lculations and reports Should have advance DICOM facility DICOM ready amp capable of networking and communicating images to PACS HIS Images should be exported to PC compatible TIFF format or DICOM format Patient database should be sorted by name registration no and study date The system should have facility to connect with multiport laser camera Should have inbuilt image management facility with built in hard drive facility for digital storage and retrieval of B W and color image data both frozen amp cine loops and on removable media CD DVD in all standard medical formats like DICOM Archive should have multi session built in CDRW Please give storage capacity of built in hard drive of the system Peripherals B W thermal printer of high quality latest model of reputed company for image print outs Colour inkjet printer of high quality latest model for image print outs Online UPS with 30 mins Back up to support all functions of the equipment Hydraulic patient couch of reputed model 100 transducer jelly bottles 100 transducer covers 100 print rolls and 100 cartridges for B W thermal printer 100 print rolls and cartridges for colour inkjet printer 2 operating chairs for radiologist Transducers Transducers should be broad band width beam former technology for extreme high resolution 2D and other mode imaging Should be ergonomically designed light weight comfortable to handle Durable easy to change Vendor should s
118. led inside of body Rotor 1 5ml x 12 places Stainless Steel chamber PGI MM PM SSY 09 10 N B 81 Low Speed High Capacity Refrigerated Centrifuge Maximum Speed 9000rpm Max Centrifugal Force 9600G Max Capacity 250ml x 4 Temp Setting 9 C to 35 C Safety Mechanism Imbalance Detector Door interlocks Door open Close detection over Speed detection Circuit detector Temp error detection Rotor ID Electronic breaking Speed Force Temp and Time Control Digital Microprocessor Control With Swing Out Rotor with different buckets for tubes ranging from 5 ml to 250 ml volume Power requirements AC220 230 240V 50Hz 30A Warranty for 5 years PGI MM PM SSY 09 10 N B 82 Digital Analytical Balance Monopan Balance Specification Compact chamber with wind drift shield provided with three slinind doors Digital LCD display Automatic calibration with built in motorized weights built in motor driven touch key Range 0 0001 gm to120 gm provided with large triangulate pan MODEL 1248 230V AC 50Hz cycle PGI MM PM SSY 09 10 N B 83 Refrigerators Specification Frost free system with Volume of 300 345 L Te sssmp Range 2 C to 14 C Microprocessor controlled temperature system with digital temperature display Fan Forced air circulation Door open alarm and abnormal Hi Low temp alarm 1 2 3 4 6 Double layered glass door with heat reflective filter and sliding doors 7 8 Interior made of backe
119. length 10 mm length of Jaw serrations 28 Mini Bull dog clamp CVD 35mm CVD 35mm 29 Mini Bull Dog Clamp CVD 45 mm CVD 45 mm 30 Bull dog clamp De Bakey Curved 78 mm 18 mm length of jaw serrations 86mm 26 mm length of jaw serrations 31 Cooley vascular clamp coarctation Gentle curve of the jaw patent ductus clamp Total length 18cms Length of serrated jaws 63mm 32 Debakeys vascular clamp Gentle curve of the jaw patent ductus clamp Total length 20 cms Length of serrated jaws 92 5 mm 33 Cooley vascular anastomosis clamp 16 5 cms length 30 degree Jaw angle single angle curve of jaw 34 Cooley vascular clamp ring handle Double angled curved jaw length 11 5 cms bull dog clamp 35 Baby Satinsky vascular anastomosis Double angle curve Jaw clamp length 150mm 36 Cooley vascular anastomosis clamp double angle curved atraumatic jaws double angle curve jaw Length 16 cms Jaw width 24 mm 37 Cooley vascular anastomosis clamp Double angle curved jaw Length 17 5 cms Jaw width 20mm 38 De Bakey Satinsky tangential Double angle curved jaw occlusion clamp Total length 23 5 cms Jaw length 68 mm Width of jaw 32mm 39 DeBakey tangential occlusion vascular Total Length 22 cms clamp double angle curve jaws jaw width 38mm 40 DeBakeys dissecting amp ligature Atraumatic jaws smooth rounded curve forceps profunda clamps Total length 19 cms Length of serrated jaws 77 mm 41 Artery c lip Micro Ha
120. ler amp M mode data System should have advanced image processing algorithms to reduce the speckle and artefacts for improved image quality Minimum screen distortion of image vendor should qualify the screen distortion of image Vendor should specify the resolution error margins incorrect calculation of hard copy provide test pattern Should be having panoramic imaging or equivalent please specify details Should have a minimum of 3 active ports with direct switching from console More active ports would be preferred Transducers should be interchangeable between ports Six or more configurable transducer holders to support all transducer designs amp provide gel storage Special transducer holder provides secure storage amp easy access to endocavitary transducer facility to remove transducer holders for cleaning purposes Should have foot switch serial port RS 232C connector USB 2 0 ports Direct connectivity to B W printer and inkjet colour printer for printing images amp report Should be DICOM ready with send receive store print and worklist enabled Should be environment friendly and should perform satisfactorily between ambient temperature range 5 degree C to 45 degree C and humidity 20 85 non condensing during operation Should be ISO amp CE certified Monitor High resolution minimum eye strain LCD TFT monitor 15 inches which should have tilt amp swivel facility and rotate along with control panel Vendor sho
121. lour maps n Onboard archival facility with easy and rapid retrieval of images in the form of integrated DVD CD RW MOD drives Should be able to store static images and cine clips in system hard disk and in on board archival devices Integrated 80GB HDD 0 At least 5000 image storage and recall facility p Integrated recording keys for remote control of peripheral devices q It should be possible to annotate and perform measurement functions on recalled images Dual image dual composite image for linear and display of B M mode images in various size combinations s Triplex mode simultaneous 2D Colour Doppler and PW Doppler t Application specific programmable annotations and bocfy marks with image plane orientation u Space for keeping ultrasound gel bottle v Internet port for networking and USB port It should be possible to transfer images to the supplied desktop Pfc Essential requirement a The machine should be supplied with a high resolution B amp W thermal printer It should be possible to print Images from the ultrasound machine console b Trolley The machine and the printer should be mounted on a trolley with lockable castor wheels c Suitable online UPS for the equipment with 30 minutes back up h High resolution photo quality Colour Printer for providing printed reports and colour Doppler images to patients Installation Base Firm to furnish a list of reputed Indian Foreign medical instituti
122. lowing movements i Vertical movement from isocentre 60 130cm or more ii Longitudinal movement upto 100cm iii Lateral movements 25cm iv Couch rotation about isocentre 100 degree C All the movements should be both motorized and preferably manual also The table should include carbon fibre panel side rails amp tennis racket insert Should have facility for patient positioning index immobilization system Couch control should be able to control room light field light SSD light and lasers Two hand pendant having the couch control features mentioned above should be provided 3 4 Operational requirements 1 The simulator shall include an integrated digital imaging capability which will allow the acquisition and display of live fluoroscopy distortion free images from the simulator to display immediately Anti collision prevention system and anti collision software avoidance system to be provided 2 Automatically captures and stores images and simulator parameters patient name and identification Provide the ability to control pan and zoom Provide the ability to zoom two or more images by the same amount simultaneously Include the ability to adjust window and level 3 Provide the ability for annotation in region of interest ROI overlays Provide digital delineator wire display Provide the ability to have the live fluoroscopy and a static image displayed alongside Provide the ability to overlay two images in one wind
123. m amp 10 mm Suction irrigation machine Knot pusher Sterilizating tray for instruments sterilization Trolley for equipments Uterine manipulators PGI MM PMS Hysteroscopic Equipments inu 4mm o degree autoclavable hysteroscope 4mm hysteroscope diagnostic sheath outer PGI MM OT Patient Positioning Appliances 15 09 10 Patient positioning devices to minimize potential tissue injuries by absorbing compression forces redistributing pressure and preventing stretching The product should be light weight made up of foam and silicon gel in two protective layer The product should be e Resistant to OR environment disinfectants e Latex free and non allergic e Heat resistant e Provided with repair kit Must be guaranteed against the manufacturing defect Following types are required e Prone head rest Supine head rest Contoured arm board pads Prone positioning system Lateral positioner Flat bottom chest rolls Crutch stirrup pads Knee pads Heel pads Search protector PGI MM PMS Sonicator Ultrasonic Disruptor ns oe Designed for biological and liquid processing applications where precise Control and parameter measurement is required Front Panel with 80 characters LCD for parameter setting Alarm message during operation Stop pause button on front panel allows for experimental cycles Setting of Amplitude from 10 100 Sample Hold using pulse pause operation Auto stops at the end of cycle using limits
124. mated Methodology end point two points kinetic method turbidimetry Analysis items analyzing max 45items at the same time Max speed 400text hour with single reagent Sample setingings 60 sample positions Sample volume 3ul 50ul step by 0 lul Temperature control 1 temperature fluctuation of reaction tray is 40 1 2 reagent bank in refrigerator Reagent positions 45 Reagent volume R1 25 300ul R2 10 150ul step by 0 lul Cuvette 120independent reaction corvettes optical path length 6mm Cleaning automatically cleaning Calibration one point multipoint Testing wavelength single and double wavelength text Wavelength range 340 405 510 546 578 600 660 700 Linear range 0 000 2 500Abs Emergency function yes Automatic string function yes Power supply AC220v 22v 50Hz 1Hz Diemention 1020mm 830mm 1220mm PGI MM PM SSY 09 10 N B 99 Syringe Infusion Pump Specification AC Powered 220 with battery back up to 2 hour or more stackable in combination Infusion Mode continuous preset volume preset time and intermittent Programming Modes volume and mass unit Volume ml hr and mass units infusion programming Infusion Rate Range 0 01 200 0ml hr Preset Time Range 4seconds to 24 hours or stat Accepts and automatically senses the size of syringes from the major manufacturers In line pressure sensing and occlusion alarm volume infused totalizer Accepts electrical input from one cable for stacked pumps Automatic anti free flow locking device Autom
125. n application support and service lab facility in India PGIMM PM CO2 Incubator aN E Shall be size 12 to 14 cubic feet Quotes on 2 units totaling 12 to 14 cuff acceptable Water Jacketed Double Doored 12 Shelves Stainless steel interior and shells Temperature Range 5 above ambient to 60 degrees C Temperature Conotrol 0 1 Degree C Humidity Control Infrared or Thermal Conductivity CO2 Control Temperature CO2 and Humidity Digital Display Over Temperature Control Built in on demand sterilizer facility for automatic decontamination at 140C Net Volume 230 Lit Approx Microprocessor control for all functions Temperature range 5C above ambient to 50C CO2 range 0 20 Digital display and control of CO2 with auto zero calibration Dual beam IR sensor for CO2 Control CO2 Accuracy better than 0 1 Digital display and control of humidity form ambient to 95 Active humidification system with capacitive sensor and external humidity reservoir Visible and audible alarm for deviation of temperature CO2 Rh and power failure PGI MM PM SSY 09 10 N B 95 UL CE and ISO Certified 100 HEPA filtered air circulation with class 100 air quality Stainless steel perforated shelves 5 Nos Double stage and double gauge CO Gas regulator with safety valve HPLC High Protein Lipid Chromatography Specifications Dual Solvent Delivery Modules to provide precision flexibility and reliability for
126. nd data storage with playback ability With picture freeze function Single Twins Monitoring selectable 9 chip pulse width beam probe Extra long life high resolution built in thermal printer which can output waveform text and other information Preferable to have twin monitoring USG probe Built in communication interface can be connected with central monitoring system Ultrasound probe with nominal frequency 1 0MHz FHR RangeL165BPML1210BPML Accuracy 20 Manual push button I Operated by pregnant womenL PGI MM PM SSY 09 10 N B 17 Maternal amp Fetal Monitor For use in both the labour rooms Maternal Parameters ECG SPO2 NIBP RESP TEMP Pulse rate Automatic Fetal Movement Detection AFM waveform display 24 hours monitoring data storage and reload Fetal heart rate Acceleration and Deceleration measurement ability Baseline acceleration and deceleration analysis capability Easy operation by with shortcut key and rotary knob Automatic monitoring mode parameters configurable Clinical data management can be reload reanalysis reprint Visual and audio alarm comply with international standard Printing functions and support external thermal printer or inkJet printer Built in rechargeable battery DC AC power supply Built in network capability Five monitors to be placed in clean labor room should have individual bed side display and also connected to a single centrally placed large color TFT screen display TFT screen and it s
127. nstruments Laparoscopic coagulating shears 10 mm diameter approx 34 cms long Laparoscopic hand activated coagulating shears with clicker 5 mm dia curved mode approx 36 cm Long Hand activated coagulating shears with clicker 5 mm dia Curved mode approx 23 cms long PGI MM PM SSY 09 10 N B 41 Instrument Washer amp Disinfector Instrument Washer and Disinfector e Ergonomically designed disinfecting washing machine to clean all type of surgical instruments Peristaltic dosing pumps for chemicals Mircroprocessor controlled Level control with minimum level alarm for chemical containters of about 10 15 Multiple pre set programme Total control of cycle parameters Exhaust air connection amp drying unit with double filter Heating power of 03 KW Washing chamber made up of AISI 316L Steel Self cleaning chamber with rounded corners Three level water filtering system Manual operated bottom hinged door Automatic rack coupling system for injector cleaning and drying Thermal decontamination up to 93 C External dimension 600 X 660 X 1700mm Rack Dimension 505 X 570 X 530mm Maximum basket capacity 160 ltrs Electrical tank heating boiler for pre heating Front loading The equipment should comply EN ISO Specifications Inserts designs should hold different type of surgical instruments and tubular scopes and appliances anesthesia tubings etc The warranty of equipment will be five years e Comprehensi
128. nvex with variable angle b Linear with beam steering and virtual convex c Sector with Trapezoidal format Transducers All the transducers should be light weight electronic arrays with wide bandwidth and Multi frequency capabilities At least three universal ports should be there for Imaging transducers Fast Selection of transducers should be possible with single keystroke Transducer cable management system should be present At least four slots holders for safe parking of not in use transducers Following transducers and accessories for different clinical applications are to be supplied a Convex array for general abdominal and obstetrics use covering frequency range of 2 5 MHz b Convex array for pediatric and early obstetrics used covering frequency range of 4 10 MHz c Linear array for small parts and vascular use coveting frequency range of 4 10 MHz d Endocavitary probe for TVS and TRS use covering frequency range of 5 8 MHz e Biopsy attachment for one Convex Linear and Endocavitary probes Measurement calculation and Reports a Trackball with multiple sets of depth distance area b Circumference volume ratio angle slope time velocity heart rate etc At least 6 distance measurement should be possible on one image c Comprehensive measurement and calculation packages for all the clinical applications including tables and summary reports d Equipment should have multi gestation measurement and reporting capa
129. of the order he they must bring the same to the notice of the Institute and seek clarifications Supplier will be to bear the responsibility for failure to take this action The Institute may in writing make any revision or change in the purchase order including additions or deletions from the quantities originally ordered in the specifications or drawings If any such revisions changes affect the price or delivery the same shall be subject to the adjustment of price delivery where required on a reasonable basis by mutual agreement in writing which should be communicated The tenderer shall also furnish performance bank guarantee of 15 of the order value or FOB value at the time of shipment or supply of goods and this will be relapsed after the successful completion of warrantee period The Institute reserves the right to cancel the purchase order or any part thereof and shall be entitled to revise the contract wholly or in part by a written notice to the vendor if The Vendor fails to comply with the terms of the purchase order including specifications and other technical requirement The vendor becomes bankrupt or goes into liquidation The vendor fails to deliver the goods in time and or does not replace the rejected goods promptly Areceiver is appointed for any of the property owned by the vendor Upon receipt of the said cancellation notice the vender shall discontinue all works of the purchase order and matters connected with it
130. ompatible for upgrade to a cone beam CT and Table top should have minimal attenuation and compatible for cone Beam CT Imaging The simulator is to be digitally x ray controlled with a workstation for planning and calculation of the treatment time with DICOM RT capability to export the plan to the treatment units 2 2 Turnkey installation including civil electrical and air conditioning works should be included as per the turnkey scope 3 Technical Specifications 3 1 X Ray Tube 1 High speed rotating anode with dual focal spots 2 The generator is of minimum 150kV 30kW output system with pulsed fluoroscopy 3 Automatic exposure and brightness control required 4 The Kilovoltage control shall range from 40 kV to 120 kV either continuously variable or in at 1kV steps The mA control should be continuously variable in the manual mode up to the maximum current rating 3 2 Fluoroscopic Imaging System The imager shall be the state of art design with amorphous silicon flat panel detector system The imaging area to be of minimum 390 x 290 mm with pixel matrix 1024 x 768 Minimum frame rate per second is 6 Higher frame rate preferred Limiting spatial resolution 1 25lp mm 3 3 Mechanical specifications 1 The isocentric accuracy should be imm guaranteed for 10 years 2 Mention procedures to ensure this Without procedural details the technical bid will not be accepted 3 Gantry rotation should have a range of 185 deg
131. on Image Output Format BMP or TIFF Camera CCD Chip Dimensions 2 3 diagonal Image Size 1392 x 1040 8 bit Pixel Dimensions 8 98 x 6 71mm 19 PGI MM PM SSY 09 10 N B 20 SOFTWARE is designed to cover No Important areas in a fertility clinic It can be used in a LAN environment with Multiple users Degree of access to individual User can be pre defined by the administrator With Hard ware Lock System Requirements Minimum requirement is Pentium II or higher Computers with 64 MB RAM 20 MB of free hard space Windows operating system LAN connection 4D Ultrasound The system should be a state of the art high end digital system with special use for obstretic and gynecology practice with continuous wave doppler imaging Please mention the Year of introduction Firm to furnish a list of reputed Indian medical institutions where the equipment is being used for fetal scanning along with satisfactory performance certificate from the users Scan methods Convex Linear Volume Phased array sector The system should have the following scan modes 2D 3D with multiplanar reformatting 4D M Mode PW CW Colour Flow Imaging Colour Power Angio Imaging Directional colour Power Angio Imaging Volume imaging System should have colour compare mode colour power mode and the normal gray scale mode side by side or equivalent The system should have a floating key board with Backlit alphanumeric disp
132. on Microvascular factors Perpheral Nerve Cleft 0 4x 2 4x activation by handgrip and foot control panel manual override palate and Internal motorized fine focusing system activation by handgrip and foot control panel continuously adjustable working distance from 200 mm to 415 mm or more without exchange of objective lens manual override integrated continuously variable illumination field spot sizes Motorized XY coupling range 40 x 40 mm or more with automatic resetting at press of a button BINOCULAR TUBE 180 degree tilt able binocular tube with focal length of 200 mm Graduated knob for continuous adjustment of inter pupillary distance from 45 mm to 75 mm EYEPIECES Pair of high eyepoint widefield push in eyepieces 12 5x with magnetic locks diopter setting from 8D to 5D also suitable for spectacles wearers ILLUMINATION SYSTEM Coaxial xenon illumination 180W or more with quick action lamp changer and back up xenon lamp 180W or more HANDGRIPS Easily removable handgrips with adjustable keys for zoom and focus Four freely programmable keys for setting illumination intensity controlling the video camera FOOT CONTROL PANEL Foot control panel with 14 functions control keys for zoom and focus XY movements light intensity FLOOR STAND Rollable floor stand on base with lockable castors motorized adjustable column with reconstructive surg ery height from 1 88 m to 2 40 m carrier and swivel
133. on and Sterilization system e Air Purification System for killing bacteria and fungi stopping regeneration of bacteria and for deodorizing air Should have user selectable program for fumigation and purification modes PGI MM PM SSY 09 10 C 1 125 Specifications for Laser Resectoscope set 25 degree telescope 4 mm Light cable PGI MM PM SSY 09 10 C 1 120 Table Top Sterilizer Table top autoclave for Operation Theatre e Multiple programmed for instruments textile liquids etc with pre and post vacuum dry cycle e Microprocessor controlled cycle time amp temperature e Microbiological in built air filter e Digital Display LED of Operations in sequence and temperature and timer cycle documentation through a printer serial port connection for PC USB storage unit Front loading with Deionizer for connection to water Chamber volume 20 25Ltrs Temperature control 121 C to 134 C Operating pressures 15 PSI to 30 PSI Class B sterilizer designed to meet EN 13060 The warranty of equipment will be five years AMC CMC charges should also be offered e The firms to give installation requirement for the equipment in their technical offer PGI MM PM SSY 09 10 C 1 112 Specification for Table top high speed refrigerated microcentrifuge Table top model Refrigerated centrifuge 4 C Micro processor controlled Max capacity 24 tube tube sizes 200 ul to 2ml Max G Force 16 000 17 000g Max s
134. on production of documentary evidence Also the insurance will be arranged by the firm effective from port of shipment to Central Store SGPGIMS LUCKNOW and the charges will be reimbursed by the institute based on documentary evidence Joint Director MM for Director Sanjay Gandhi Postgraduate Institute of Medical Sciences Raebareli Road Lucknow SANJAY GANDHI POST GRADUATE INSTITUTE OF MEDICAL SCIENCES RAEBARELY ROAD LUCKNOW 226 014 Adv No 57 2009 10 SPECIFICATION FOR EQUIPMENT Tender No Specification 2 3 PGI MM PM GYNAECOLOGY EXAMINATION TABLE pun RE 4 Gynecological Examination Table made of metal frame of square pipe of heavy gauge and top sheet made of well chrome plated Should have a two sectional mattress base with perinial cut suitable for gynaecological examination It should have a detachable foot section Overall size of the table 72 x20 x32 The top of the table fitted with high density foam covered with water proof material It should have leg rest suitable for pelvic examination and colposcopy and height adjustment of the leg rest possible with the help of the knob It should have stainless steel bowl which could be pushed under the base Foot step provided with the unit for the comfort of the user PGIMM PM EXAMINATION LIGHT FNI a 42 To be used in Obstetrics OPDs m Mobile lights with 5 swivel castors Arm 105 cm articulated spring loaded arm arm with on off switch and incorporated ele
135. ons where the machine being quoted is installed along with satisfactory performance certificate from the users for obstetrics use PGIMM PM Compound analyser for serum screening AU To be used for first and second trimester serum screening during pregnancy to detect fetal aneuploidy 10 N B 22 e Technology TRACE Time Resolved Amplified Cryptate Emission technology measurement takes place in homogenous phase e Specimen Capacity Up to 64 in a maximum of 4 sample cassettes e Specimen test tubes Primary and Secondary test tubes diameter 11 17mmy variable from sample to sample e Specimen identification barcode recognition and manual entry Specimen recognition availability barcode recognition liquid level monitoring clot recognition Specimen volume 10 70 uL test specific Intelligent Auto Dilution Out of range samples are detected within 5 minutes amp auto diluted Operating Modes Random access emergency STAT Reagent capacity Up to 12 kits on board in a maximum of 3 reagent cassettes Reagent identification barcode reader and manual entry Calibration calibrtation 1 and 2 point test specific Specimen and reagent distribution 1 heated Teflon coated steel needle movable radially amp vertically automatic wash step between different tests System liquid two 5 liter containers for buffer and distilled water reservoirs with fill level monitoring enables refilling changing of liquids while the
136. ore than 2 deg c Service life of the lamp should be at least 1000hrs Should have facet type metal reflectors with infrared coating to ensure shadow less cool and steady light output over entire operating area Should have colour temperature typically 4300K Lamp cover should be made up of impact resistance plastic Should have adjustable height and an articulated arm for wide range of adjustments amp wide turning radius Should have detachable k amp sterilizable handle for aiming and focusing of light Should have main switch in the lamp head Lamp should be easily changeable without any tool Lamp head should have smooth design amp easily cleanable surfaces with good laminar flow properties laminar flow index 12 The light head should be compact and light weight for easy maneuverability Should be equipped with four castors with brakes Should confirm with International Standard for Medical Electrical equipment Working distance 700 to 1500mm PGI MM PM SSY 09 10 N B 16 CARDIOTOCOGRAPHY MACHINE Capable to monitor continuous and intermittent fetal heart rate amp maternal contraction pressure Compact and portable design can be put on table or wall mounted LCD screen display which can be rotatable up to 60 Display of the patient data and curve clearly Can record fetal movement manually High and low fetal heart rate alarm function Continuous 24 hour real time monitoring Continuous 12 hour patient curve a
137. ost MICRO SYSTEM 1 2 A INSTRUMENT FOR TITANIUM IMPLANT SET 1 Container 280 x 195 x 65 mm 2 Instrument Rack 3 Teflon Implant Tray 4 Plate Bending Plier 11 5cm 5 Plate Cutting plier TC 11 5cm 6 Plate and screw holding forceps angled 7 Screw driver with gripping device 13cm 8 Metal Handle only for Screw driver 9 Spare screw blade cross lock for screw driver 10 Twist drill with stop 1 0 x 50mm for screws up to 8mm 11 length strycker shaft 12 Twist drill with stop 1 0 x 30mm for screws up to 4mm length Dental shaft 13 Drill bit Ix83mm 14 Drill bit I x66mm IMPLANT SET PLATE amp SCREW 1 4 hole plate straight 0 55mm profile 2 6 hole plate straight 0 5mm profile 3 16 hole plate straight 0 55mm profile 4 T plate 5 holes 90 0 5mm profile 5 Y plate 6 holes 0 55mm profile 6 Double Y plate 6 holes 0 55mm profile 7 Orbital Plate 8 holes cvd 0 55mm profile 8 5 hole T Plate Rt 9 5 hole T Plate Lt 10 2x2 2 hole plate 11 4x2 hole replent plate 12 Titanium Screws cross lock 1 2 x 5mm 13 Titanium Screws cross lock 1 2 x 7mm 14 Titanium Screws cross lock 1 2 x9mm 15 Titanium Screws cross lock 1 4 x3mm 16 Titanium Screws cross lock 1 4 xSmm 17 Titanium Screws cross lock 1 4 x7mm N 1 tA OQ Q Q oo ON Q OQ LD TITANIUM MID SYSTEM 1 7 Screw Driver with gripping device Twist drill 1 4 x 94mm Twist drill 1 4 x 77mm 4 hol
138. ound blaster X Fi Xtreme music PCI Slots 4PCI slots full height IPCLe x8 mechanically x4 electrically IPCLe x16 graphic Ports Front 2USB 2 0 1 IEEE 1394 optional Rear 6USB 2 0 1 Serial 2PS 2 IRJ 45 NIC Graphics Card NVIDIA Quadro FX 1400PCLe ATI Fire GL V5100 PCLe Mouse USB Optical Scroll mouse Keyboard Standard Network Integrated Broadcom 5751 Net Xtreme Gigabite Eathernet Controller PCLe Power Supply 500watt wide ranging active power factor correction Operating System Window XP32 bit edition SP2 or Latest Warranty 5 years comprehensive on site b Intelligent Character Recognition Software P3 Item Teleform Elite edition Version 10 0 or later with media and manuals for Five users license with following modules From Designer amp Publisher Scanning Capture Connect Agents Recognition Document Capture Validation Verification Export Connect Agents c Document Scanner with ADF Specification Scanning speeds Simplex Duplex Black and White 75 ppm 150 ipm Grayscale 75 ppm 150 ipm Optical Resolution 6000 dpi Stacker Capacity 5000 sheets Scanning element Contact image Sensor CMOS Document Size Feeding Up To A3 Automatic Manual Light Source RGB LED x 4 Operating Modes Simplex Duplex Grayscale Black and white and Error Diffusion Advance Tex Enhancement Multi Stream Dropout Color RGB User selectable front back both Interface At least 2 USB 2 0 and SCSI III
139. oval The offered model must be type approved by FDA CE amp AERB A copy of the type approval from AERB must be enclosed with the offer Should have local service facility The service provider should have the necessary equipments recommended by the manufacturer to carry out preventive maintenance test as per guidelines provided in the service maintenance manual 8 Documentation 8 1 User Technical Maintenance manuals to be supplied in English 8 2 Certificate of calibration and inspection from factory 8 3 List of Equipments available for providing calibration quality assurance and routine maintenance support as per manufacturer documentation in service technical manual 8 4 Log book with instructions for daily weekly monthly and quarterly maintenance checklist The job description of the hospital technician and company service engineer should be clearly spelt out Scope of turnkey jobs for installation of the Isocentric Brachytherapy Simulator The area enclosed within a dotted line which includes presently the mould room HEK shield fabricating room and the office needs to be dismantled and modified for housing the Simulator The area included is encompassed in 6 6 x 6 6 sq m Schematic enclosed CIVIL WORKS 1 Existing walls in the mould room and the adjacent rooms to be dismantled for housing the Simulator along with the control console 2 Existing entrance to be replaced with a larger one for transporting sim
140. ow for comparison purposes 4 It should be possible to perform all movements from the control area as from within the room please indicate which functions are not available if any 5 It should be possible to set up a field asymmetrically and then convert this to a symmetrical field automatically 6 It should be possible to simulate any manufacturer s treatment machine and limitations of movement can be entered for individual machines that may be due to room limitations and not the standard configuration of that machine At least 2 in room monitors for display of data 3 5 DICOM connectivity Full vendor independent connectivity to DICOM RT and integration with the existing network for patient information management systems and treatment parameters of the department Export of Dicom SC CR and RT image with contours Import and export of DICOMRT Plan incl MLC and image 3 6 Workstation hardware and software 1 The latest state of art hardware to be provided 2 Automatic treatment machine configuration 3 Multiple plans per patient multiple fields per plan multiple images per field 4 Patient plan and field information and selection in clear tree structure overview 5 Light box for clear overview of images with drag and drop image movement 6 Live fluoroscopy last image hold Automatic opposed field automatic image merge up to 10 images and film exposure acquisition modes Images imports of DRR s 7 A wide range of
141. pable of warming at least three segments at a time Should offer precise digital temperature control with selectable temperature range of 30 to 40 C in steps of 0 5 C Control panel should display intended and actual temperature Should have safety features such as Automatic check Precise temperature control between warming system and patient Autostop on detecting any problem Should have non latex anti bacterially coated blood and fluid Resistant covers Covers should be washable autoclavable and replaceable The control unit should be light weight not more than 2 5 kg small in size 25x10x20 cm approx and easily attachable to IV rod OT table with fixing claw Should have low energy consumption and noiseless operation Paediatric Thermal mattress Specifications To prevent intraoperative hypothermia in paediatric patients undergoing major surgical procedures e Double layered polyurethane mattress with washable cover to eliminate the leakage of fluids etc into the mattress e Flexible mattress with insulation resistance of more than 3K V e Sophisticated digital control system to detect even minor variations in mattress temperature with continuous monitoring with dual sensor system e User friendly soft touch panel with Bar Graph display of percentage of Heater Power Output e Resolution 0 1 C e Over temperature alarm Under temperature alarm cut off alarm power failure alarm Audio Visual e Operating voltage 230VAC 10 Mattress oper
142. pairs free of cost The Infiltration Device should be provided as standard accessory to the power assisted suction 1 Should allow the use of any size of infiltration Bag from 500cc to 3000cc 2 Should eliminate the use of Y connectors 3 Should be operated with Power Pack Platform electrically OR by gas 4 Should quickly depressives and exhaust the inflation bladder at the touch of a switch 5 Should have ease of adjusting the constant pressure by a simple turn knot 6 Should have large monitoring gauge for easy monitoring 7 Should have large door and automatic deflation of bladder for easy opening and closing of door of Cannullae as standard part of the equipment to be provided PGI MM PM SSY 09 10 N B 67 I Electrical Console with Foot Pedal Option with facility for dual hand piece II Power Assisted Electrical Hand Piece Electrical Cable III Cannula tips a Mercedes 5mm 26cm length b Mercedes 4mm 32cm length Mercedes 2mm 26cm d Keel Cobra 4mm 26cm e Sterilization Tray for cannula and tubing IV COLEMAN INFILTRATION CANNULLAE 1 Coleman infiltration Cannula 2 Coleman Concave infiltration Cannula 9cm 3 Coleman Convex Infiltration Cannulae 9cm 4 Coleman S Infiltration Cannulae 9cm 5 Hunsted handle for Coleman 6 Standard two slot cannula tip DRESSING SET FOR WARD Item Straight Mosquito Forceps Curved Mosquito Forceps Thumb For
143. pecify the weight foot print size FOV Band width viewing angle in degree depth of scan 3D facility facility of biopsy attachment cost of each transducer Vendor should specify the mode of sterilization of each transducer Other probes to be quoted Broadband convex curved 2 5 MHz with biopsy attachment Broad band linear probe 5 10 MHz with biopsy attachment Other probes to be quoted Microconvex probe for paediatric abdominal use Microconvex probe for neonatal head Wide band width linear probe 5 13 MHz Wide band width phased array transducer 4 8 MHz Wide band width phased array transducer 2 4 MHz Wide bandwidth micro curved array transducer having a frequency bandwidth of 5 8 mHz Transrectal probe biplane rectal probe Wide bandwidth volume probe Probe for intraoperative imaging General instructions for vendor Supplier must ensure availability of expertise service and maintenance at Lucknow Supplier must ensure spares availability including transducer and repair for next 10 years after expiry of warranty PGI MM PM SSY 09 10 N B 51 PGI MM PM SSY 09 10 N B 52 Comprehensive maintenance contract rates including spare parts and probes should be quoted for next 5 years after expiry of warranty Supplier should provide two sets of user manual CD DVD in English Supplier will be asked to demonstrate its quoted model when and where required along with quality control program for system performance Supplier must at
144. peed gt 12 000rpm Rotor Fixed angle 2 types for tube and PCR strips Motor Brushless Frequency controlled induction drive PGI MM PM SSY 09 10 C 2 17 Specifications for MR compatible stereotactic frame Stereotactic head frame with localization accessories 1 Coordinate stereotactic frame 2 Stereotactic arc with clamp 3 CT and MR adaptor with table fixation device 4 Backward biopsy kit including accessories for fine needle biopsy spiral biopsy and aspiration kit 6 Side cutting biopsy needle kit 7 Haematoma evacuator kit 8 Endoscopic adaptor 9 Neurogenerator 10 Brain lesion electrodes amp bipolar kit 11 Electrodes for pain treatment PGI MM PM SSY 09 10 C 1 45 Walk In Cold Room Specification Size 10x10x10 feet Temp 4 8 deg Centrifuge flush type door with cooling pre fabricated panel of SS with floor panel internal side should be of SS dull finish outer pre painted SS sheet powder coated alarm system with internal opening safty device can and lock system Racks for stainless steel for cold room 4 tiers made up of 16 gauge SS sheet and SS angle for keeping vegetable milk egg butter fruits paneer etc PGI MM PM SSY 09 10 C 2 11 Clinical Scale Magnetic cell Sorter for Isolation of CD 34 Stem Cell 1 Automated immuno magnetic cell separation system with high purity and yield 2 Minimal or no handling of cells in the operation of the system 3 Compatible for clinical or ster
145. plied with gt 2 0 GHz 2512 MB RAM gt 160 GB hard disk Workstation Should be equipped with windows based acquisition and analysis software The system should be equipped with cell sorter as built in module for safe closed piezo sorting Sorting Speed Input upto 100 000 cell per second and Output upto 300 cells per second Purity of sorted fraction 99 system should have an 96 well plate sampler upgrade option PGI MM PM SSY 09 10 N B 113 The system should have an option for immersion gel coupling for detection of weak cytokines Following items to be provided along with the system 1 Sample tubes 5000 no 2 Sheath Fluid production kit for 200 Ltrs 3 Cleaning solution 4x 250 ml 4 Decontamination Solution 2x 250 ml 5 Hypochlorite Solution 1x 250ml 6 Suitable Online UPS to run the entire system 7 LaserJet Printer Warranty Five years Portable Color Doppler Ultrasound Unit Fully digital compact portable Color Doppler Ultrasound machine is required with following technical features e The unit should be compact lightweight and portable Specify weight and dimensions e Jt should be suitable for Obstetrics and Gynaecological applications e The unit must have real time compound imaging for improved contrast resolution and eliminating ultrasound artifact to achieve optimum image quality on convex amp linear transducers e The unit must have automatic gain adjustment for B mode e Scann
146. r d Automatic leak compensation e Apnea back up ventilation f Numeric display of set inspiratory expiratory pressure and leak g Alarm for leak and disconnection h Compatible integrated humidifier i Flexible plastic tubing atleast 2 m in length j Built in air filter k T wo adult full face mask with their head straps 1 All necessary tuubings connectors adaptos and cables PGI MM PM SSY 09 10 C 3 05 SPECIFICATIONS FOR FLOWCYTOMETER Latest industry standard computer Pentium processor The flowcytometer system should ultra compact fully equipped Bench top instrument devoid of any paraphernalia like gas cylinder pressure regulator etc The system optics should be Alignfree so that time consuming optical checks realignments of the laser and readjustments of the optical systems are eliminated The instrument should be equipped with following laser light sources Blue Solid State Laser 20 mW 488nm Red diode laser 25mW 635nm UV diode laser 16mW 375nm System should have 8 Optical parameters Six Colors FL1 FL6 Forward Scatter FSC Side Scatter SSC system should have CCD Video camera for Sample flow monitoring Should have the facility of True Volumetric absolute counting based on precise sample volume measurement System should have contamination free computer controlled digital syringe pump for sample transport Adjustable pump speed and Sheath fluid pressure Should be sup
147. r bedside procedure and minor operation procedures Gives Cold bluish white light of high intensity Xenon lamps Parabolic reflectors Swivel neck and dome Height adjustment by spring collet Easy manoeuvrability Built in transformer PGI MM PM SSY 09 10 N B 35 Portable electrical slow suction machine Specification To provide continuous controlled low pressure negative suction to 1 facilitate lung expansion in patients with intercostals chest tubes and ii upper esophageal pouch suctioning in esophageal atresia to prevent aspiration Light weight less noisy compact Non motorised electric magnetic pump Stepless power adjustment facility Provided with 500 ml liquid bottle Work on 220 v ac Pressure range 0 to 220 mm hg PGI MM PM SSY 09 10 N B 36 Pediatric laparoscopy set 1 Camera 2 Full high definition HD camera Progressive scan technology 1920x1080 pixels or better resolution 16 9 format with integrated image processing modules Parfocal zoom lens with optical and digital zoom focal length 14 30mm 2X Digital input and output connectors 2 freely programmable camera head buttons 3 Monitor 23 inch or better HD flat screen medical grade monitor 16 9 Aspect Ratio Color system PAL NTSC Resolution max 1920x1200 SDI Multimodality image viewing with S video RGB BNC DVI VGA cable connection 23 HD TFT flat screen 4 Telescopes Straight forward telescope 0 degree diameter 5 mm
148. rees for an FAD of 100cm 4 Congruence between the mechanical and radiation isocentre during rotation 0 5 at isocentre 5 Mechanical and digital readout at local and remote console with accuracy 0 5 degree 6 Gantry auto stop position at 0 degree 90 degree 180 degree and 270 degree 7 Focus to axis distance range scale indicator from 75cm to 140cm 8 Mechanical and digital readout indicator for gantry imager and table position to be of accuracy 1 9 Collimator rotation range from 180 degree with variable speed and auto stop at 0 degree 90 degree 180 degree and 270 degree 10 Mechanical and digital rotation resolution of 0 1 degree 11 An optical SSD indicator should be installed to accurately measure distance from 75 to 140cm Height of the isocentre above the floor should be equal to or less than 130 cms 12 Field wires for symmetrical and asymmetrical field sizes Field size to be motorized and provide for a range 0 5 x 0 5 cm to 40 x 40 cm at FAD 100cm Coincidence between the X ray image and light image for the cross wires is 0 5 mm diameter at 100cm FAD over the full rotation range of the head Coincidence between the X ray and light field is 1mm with a 15x15 field at 100cm FAD for all other rotations Treatment Couch This should be light weight made of carbon fibre with controls on both sides The couch should have following features a The weight capacity should be upto 200Kg b The couch should have fol
149. rison Incase vendors quote separate foreign currencies for the equipment the exchange rate will be reckoned on the date of opening of price bid as provided by the State Bank of India SGPGI branch 4 The firm should do the custom clearance and pay the custom duty and transportation up to the site for installation The custom duty as per actual would be reimbursed by the institute The interior modification for housing the simulator unit its shipping and installation should be co ordinated by the firm so that the machine does not lie idle All papers related to procurement and interior modification will be provided by the institute 5 Indigenous items should be specified separately and quoted in Indian rupees 6 The firm would be responsible to meet any unforeseen expenses during the warranty period for maintaining and running the equipment and its accessories 7 Once the LC is established and acceptable to the vendor and the site for turnkey handed over the firm must ensure that the machine is commissioned for clinical use within a maximum period of 6 months from the date of LC or handing over of site whichever is later Institute will be committed to provide required power at the battery limits at least two months before completion of the said 6 month period Any delay in installation and commissioning including turnkey will enable penalty of Rs 25 000 per week upto a maximum of 5 of the FOB value FDA CE and AERB Type appr
150. rked It should be supplied with following accessories I V Pole safety flow meter for oxygen with adjustment range of 1 15 L min storage drawers skin temperature probe electrostatic filter dust cover oxygen Sensor PGI MM PM SSY 09 10 N B 31 Neonatal Transportation incubator Specification Essential for transporting newborns safely from one area to another within the hospital Prevents hypothermia during transport Allows administration of Oxygen and intravenous fluids during transport wall transparent hood section with electronic servo temperature control system Temp setting range from 29deg C to 37 deg C with audible amp visual high temperature alarm Standby heating mode to keep incubator ready for use Low power voltage alarm Supplied with 12 V DC rechargeable power pack compatible with 230 V AC 50 60 HZ Auto cut facility when heater gets over heated Supplied with incorporated IV pole Sould be 93 W x 41 D x 36 H cm in size and approx 15 7 kg in weight Fixed on movable trolley with lockable castors amp storage space for battery amp gas cylinder PGI MM PM SSY 09 10 N B 32 Mobile Neonatal radiant heater on stand Specifications Mobile radiant warmer on swivel castor wheels For preventing hypothermia in operation theatres and while performing certain bedside procedures Servo controlled temperature Microprocessor based electronic control Thermistor based temperature probe
151. roscope diagnostic sheath outer PGI MM PM Sequential Compression Device for Lymphedema SSY 09 10 N B 97 Specification Should be a sequential compression device for providing graduated sequential compression and rapid impulse inflation to Calf amp thigh It should have sequential pulse frequency with choice of treatment of one or two limbs simultaneously It should not require DVT sleeves below cuff It should delivers constant preset pressure range 20 80 mm of Hg Should be portable electrically operated with good battery back up with universal size of sleeve to cover calf thigh amp foot Standard Accessories should include the followings Connecting tube Universal sleeve for thigh calf amp foot small Universal sleeve for thigh calf amp foot medium Universal sleeve for thigh calf amp foot large PGI MM PM SSY 09 10 C 3 06 Electrophysiology ablation apparatus Specification 1 12 Body Surface ECG 2 Number of Intra Cardiac Channels Atleast 70 3 Two channel intra cardiac pressure recording amp display 4 Digital stimulator with key board operation Two channels with at least 25mAout put 5 Off line software hardware system to Review Data one installation outside 6 Review software to upload in any computer 7 Compatible laser printer 8 Operating system 9 HDD minimum 160 GB atleast 2 5 Ghz CPU 512 MBRAM 10 Data storage patient data writable 1 1 Ease of use with preferred single key boar
152. rtmann Very delicate pattern 9 cm straight 9 cm curved 43 Micro Halstead mosquito 12 5 cms Straight 12 5 cms curved 44 Artery forceps 16mm curved 16mm straight 45 Roberts artery forceps 22 5 cm curved 46 Crafoord artery forceps 24 5 cm light curved Dissecting and ligature forceps forceps 47 Mixter right angle dissecting amp Right angle dissecting and clamping forceps ligature forceps very delicate jaws with longitudinal serrations cross serrated tips 18 cms 22 cms 25 cms 48 Lahey dissecting amp ligature Forceps Fully curved jaws with longitudinal serrations 20 cm 23 cm 49 Micro Adson dissecting amp ligature 14 cms forceps Tissue holding clamps sponge holding forceps towel clips 50 Desjardins gall duct amp cystic forceps 22 cms 51 DeBakey atraumatic Intestinal amp tissue Intestinal amp tissue holding forceps clamp holding forceps clamp jaws with atraumatic serrations Jaws 20 mm wide 25 cms 52 Backhaus Towel clamp 8 0 cms 11 cms 53 Simplex tubing clamp 12 mm width 54 GROSS dressing and sponge forceps Atraumatic serrated jaws with slender oval with catch fenestration with catch 14 5 cms curved 18 cms curved 55 Foerster ballenger Sponge holding Small loop jaws serrated 18 cms straight 24 5 cms curved 56 Baby Allis 13 cms length 4x5 teeth 57 Boys Allis 15 5 cms leng
153. s 99 De Bakey suction canula Whth finger cut off amp stylet Olive diameter 9 mm Length 160mm 100 Adson suction canula Whth finger cut off amp stylet Olive diameter 8mm Tip diameter 3 mm Length 16 5 cm 101 Barron suction canula Whth finger cut off amp stylet Tip Diameter 2mm Length 16cms 102 Zoellner suction canula Diameter 2 5 mm Length 180mm Miscellaneous trays and bowls 103 Kidney tray set All sizes Round bowls set BP handle For all sizes of blades PGI MM P MSSY 09 10 N B 28 PGI MM PM SSY 09 10 N B 29 PGI MM PM SSY 09 10 N B 30 Pediatric Thermal blanket Paediatric Patient Warming System To prevent intra operative hypothermia in paediatric patients during major surgeries Consist of active warming arm cum shoulder section pair of leg segments and 1 double segments to cover the entire body Size Double Segment 30 35 cm x 65 70 cm Arm amp Shoulder Section 130 135 cm x 25 30 cm Leg Segment 30 35 cm x 50 55 cm Double segment and arm cum shoulder segment should have two temperature sensors each for precise temperature control Double segment and arm cum shoulder segment should be divided in two sections capable of being switched ON or OFF independently depending upon the nature of surgery and condition of patient Should have a control unit to regulate warmth to every area precisely by use of carbon fibers Control unit should be ca
154. s agreed under negotiations would be provided at our Institute without fail Any negligency on this account shall be the sole responsibility of foreign vendor and the liability of compensation will be fixed up by the Sanjay Gandhi Postgraduate Institute of Medical Sciences Lucknow A Comprehensive offer of same for 5 years would be finalized before placement of order either on comprehensive or semi non comprehensive basis with or without spare consumables Accessories including labor charges by the Institute to the tune of 95 uptime of equipment that AMC will be effective after expiry of warrantee period The price bid will be opened in the presence of authorized representative of qualified tenderer within 45 to 60 days from the date of opening of technical bid The price ranking will be carried out as under i The exchange rate of last date of submission of bid will be applicable for price ranking ii The prices for optional items will be excluded for ranking purpose i e L 1 L 2 etc iii After omitting optional items ranking will be determined as under Total Price Price with all accessories as per technical specification CMC Price with spares for five years after warranty The supplier will get the equipment consignment cleared from the custom The Custom Duty and clearance charges as well as freight charges will be borne by the manufacturer Indian representative at the time of clearance which will be reimbursed by the Institute
155. s for biopsy Optical universal forceps Optical suction tube outer diameter 2 5 mm 3 mm Glass window plug Rubber telescope guide Adaptor with sliding glass window plug sealing cap notched lens amp keyhole opening Guide piece for suction catheter Adjustable magnifier Adaptor for respirator Magnetic extractor for removal of magnetisable foreign bodies Corkscrew extractor for removal of soft difficult to grasp foreign bodies Camera light source and fibre optic light cable as per specifications given in pediatric laparoscopy set same would be used for bronchoscopy PGI MM PM SSY 09 10 N B 39 Urodynamic study equipment Specifications Flow transducer Measuring range 0 50ml sec Resolution 0 03ml sec Patient safety ensured by galvanically isolated flow channels Pressure transducer 4 Inputs P1 Pves P2 Pabd P3 Pura and P4 Measuring range 50 cm H20 to 4350 cm H20 Resolution 0 2 cm H20 Puller with arms Speed range 0 5 5 mm sec Accuracy 0 03 mm s Usable length 300 mm Water pump Infusion Rates 2 10ml min in steps of Iml min 10 100 ml min in steps of 5 ml min Accuracy 50ml min 3 of actual value 1ml min gt 50ml min 5 of actual value 1ml min Patient safety Software controlled Autostop if the Intra vesical Pressure exceeds a particular preset limit PGI MM PM SSY 09 10 N B 40 Ultrasonic cutting amp coagulating device for open and laparo
156. s patients minimizing the risk of injury and strain for the carer e treatment system should be rectangular in shape with seamless smooth rounded corners Should have electric Height adjustment 625 mm to 1110 mm Should have tub size length 1875 mm width 750 mm Should have handgrip shaped rim with protective strip Should have foot support pillow package Should have high finish polished amp acid resistant surfaces for disinfection Should made from High quality stainless steel EN 1 4436 SS2343 ASTM3 16 for durability Should be equipped with Electric control panel with push button operation Should have thermostatic cartridge including 3 mixers for quick water filling Should have thermostatic mixer for soft showering Should have thermometer for control of fill water temperature amp patient shower Should have triple anti scalding protection with selectable Maximum temperature at 41 C amp automatic Electronic shut off at temperature above 42 C e Should be equipped with Dual patient showers and equipment cleaning shower with trigger control handles e Should have Built in disinfecting system including o Color coded disinfectant shower with trigger control handles o Safety back flow prevention system o Disinfectant solution jar minimum 1 Liter o Visual Dilution control with dosimeter and adjustable screw o Disinfection system is deactivated if patient is in the bath Should have cleaning shower fitted with a dosage device flow meter Should
157. scopic surgery Specification Ultrasonic generator with a frequency of 55 5 KHz capable of incising tissue and providing hemostasis with minimal thermal injury For both open amp laparoscopic surgery Both Smm amp 10mm instruments Vibration range 50 120microm Range of laparoscopic amp open shears 10 mm coagulating shear capable of working in 3 modes flat blunt amp sharp Hand activated 5 mm curved coagulating shears 360 degree rotatable having min max switches to enable precise operation Open amp laparoscopic shears capable of coagulating vessels upto 5 mm Rotating hand switch adapter with bilateral min max switches to enable precise operation of system by hand for hooks and blades Dual foot receptacles to connect two footswitches to allow simultaneous use by two surgeons Power entry filters to suppress electromagnetic disturbances to other monitors and is defibrillator protected System diagnostics amp trouble shooting guide to pinpoint amp to resolve alert alarm conditions Confirms to required safety standards Hardware Generator foot switch cart Accessories Handpiece 5mm blade adapter system adapter for shears Open surgery instruments Coagulating shears 10mm diameter Hand activated coagulating shears with clicker Smm diameter curved mode Hand activated scissor grip coagulating shears 16 mm curved tapered blade capable of sealing blood vessels upto 5 mm 5 mm curved blade with grip Laparoscopic surgery i
158. smaller cassettes of 24 x 30cm 18 x 24 cm 30 x 40cm to be provided d Also provide laser printer of A3 A4 paper size for printing e Quality Assurance Phantom to study organ motion to be provided Cone Beam Computed Tomography Optional All hardware and software for performing cone beam CT for image guided brachytherapy Also include CBCT phantom and required accessories CBCT images should be ready for any TPS planning through Dicom RT export Important note The prices for CBCT should be enclosed in a sealed envelop separate from the main price bid valid for 1 year 5 Environmental factors 5 1 5 2 5 3 5 4 Housing requirements fire safety and installation should take care of local regulations in mind All expenses as detailed below should be included in the bid a Installation Included in the cost of main equipment b Construction Modification for housing the unit including supplementary airconditioning Also include adequate furniture in these rooms Details of room plan modification are included in these specifications Necessary modifications in the room if needed should be discussed and specified in consultation with the department and included The room plan needs to be approved by AERB and modified accordingly The supplier will coordinate all the formalities for AERB approval All the documents required will be provided by the institute The unit shall be capable of being stored continuously in
159. spect ratio of 4 3 Brightness image sharpness colour balancing automatically adjusted to attain the best possible picture for the selected speciaility Light Source Xenon light source Fully automatic 300 watt Jaw mechanism for fixing the Fiberoptic cable Minimum bulb life of 2500 working hours Fiberoptic cables Atleast 5mm diameter over 6 5 feet length Monitor 26 one each flat panel custom designed with the colour depth amp enhancement requirements High resolution appropriate to the offered camera system SXGA technology 1280 X 1024 Capable of displaying SVHS VHS XGA amp DVI signals Carbon Dioxide Insufflator Preferably gt 12 litres high flow Insufflator wiyh heating Touch sreen controls Telescope 10 mm 30 degree amp 0 degree autoclavable laparoscope 05 mm 30degree Video recorder digital video recorder 4 Operating Instruments Veeres Needle 6 long Trocars pyramidal tip 5 5mm amp 11mm cannula 11mm 5 5mm automatic valve stop cock without trocar Reducers 10 5 5 mm instruments 33cm PEEK monopolar handle Maryland dissector Nontooth grasper with spoon DeBakey grasper Aspiration needle 5mm PCOD needle scissors Metzenbaun scissors 5 mm 10mm straight amp curved atraumatic double action grasper 5mm myoma screw Curved left needle holder Curved rightle holder 5mm bipolar fenestrated forceps with spring handle 5mm bipolar microtip forceps with spring handle Suction irrigation canula 5m
160. tach list of quoted model installation in reputed government institute along with performance certificate Supplier will arrange training at academic institute of repute of one doctor of the dept at their cost Choledochoscopes Specifications 1 Scope a Flexible fibreoptic 5mm forward viewing 120 degree field of view with four way angulation working length 350 400mm with instrument channel 2 Accessories Compatible light source with spare bulbs Compatible cables Biopsy forceps Grasping forceps Cleaning brushes Air Mattress for Bedsore Prevention Specifications 1 Pneumatically controlled alternating pressure pad system for prevention of pressure sores 2 On an alternating basis number of uniform sacks in the mattress inflate and deflate 3 Alternating pressure pad device aids in the movement of body fluids 4 Gradual pressure changes with no vibration or noise 5 Power supply 220 V 50 Hz 5 amps 6 Dimension of mattress 1 metre X 2 5 metre approx pn gt PGI MM PM SSY 09 10 N B 53 Specification of Operating Head Light LUXTEC 300 WATT XENON LIGHT SOCE LUXTEC DPRCIFICATION Xenon Light source 300 Watt provides bright white light Removable Lamb module the unique built in intensity wheel allows to control the amount of light desired to suit the specific procedure Guaranteed Lamp life 650 Hrs Light source has ability to attach a Varity of Head Light system Automatic Lamp shut off increase safety and lamp color T
161. tails of differences The seller shall attend the site within seven days of receipt of such notice to meet an agree with representative of the SGPGIMS the action required to correct the deficiency If the seller fails to attend meeting at site within the time prescribed above the SGPGIMS shall immediately get the same rectified the work materials and seller shall reimburse the Institute all costs and expenses incurred by the SGPGIMS in removing such trouble or defect 100 payments shall be released within 30 days from the date of satisfactory receipt of materials or satisfactory installation if applicable Where necessary performance bank guarantee 15 of the ordered value or FOB value shall be submitted to the Institute before arranging the delivery till expiry of warranty period In case of imported goods equipment the payment schedule will be as follows A 75 against shipment B 25 against installation The mode of payment will be through irrevocable letter of credit However Indian Agency Commission or Technical Services charges would be paid in Indian rupee after satisfactory receipt amp installation of goods at site Indian Agency Commission will be declared in the price bid Time delivery as mentioned in Purchase order shall be the essence of the order and no variation shall be permitted except with prior authorization in writing from Purchaser In the event of delay in making delivery on the part of the vendor it will be at purch
162. ted on a good quality trolley for easy mobility and loading unloading in an ambulance System to have 1 Incubator with Double Wall Canopy Front and Head End Access Doors With Access portholes and Tubing Access Ports retractable mattress for emergency procedures and intubations Digital Displays of Air and Baby Skin Temperatures Indicators for Battery Power Capacity Examination Light AC and 12 VDC Connectors Front mounted gas content display Comprehensive Alarm system Neonatal time cycled and volume pressure limited ventilator with IIPPV IMV and CPAP Modes Breath Rate Variable to 120 BPM Adjustable Peak Pressure and PEEP Air oxygen auxiliary blender for Fi02 from 21 to 100 Cylinder Supply oxygen Analyser with digital Display of Oxygen Concentration suction Unit suitable for Neonatal Use Trolley to be Lightweight on four locking Castors with Handles System must be Capable of being Securely installed in Ambulance System to conform to standards BO00000N IAABROOOO IEC 601 1 o IEC601 2 20 o MIL STD4 61C o MDD Directives Er Data Mining Tools and Server 1 136 Server Specification Processor Intel Xeon E5410 Quad Core 2 66GHz 2x2MB or Higher Memory Type PC2 3200DDR2 RAM 16GB extendable up to 128GB Advanced Memory Protection Advanced ECC Online Spare Plug Mirrored Storage HDD 250 GB 15000rpm Ultra 320 SCSI 3 Nos DVD 16 X VD RW Dual Layer Light Scribe Storage Type Hot Plug 2 5 S
163. th 5x6 teeth 58 Allis 19 cms length 59 Babcock organ amp tissue holding 15 5 cms Length forceps 20 cms length 60 Baby Kochers atraumatic intestinal Curved 13 cms length clamp 61 Kochers atraumatic intestinal clamps Curved 21 cms 62 Blake gall stone holding forceps Curved 20 5 cms Retractors 63 Kocher Langenback retractor Blade 6 mm wide 25 mm deep Blade 11 mm wide 41 mm deep Blade 15 mm wide 35 mm deep 64 Masing vein retractor Blade 6x12 mm length 14 cms 65 Cushing Vein retractor Length 17 5 cms blade 10X10 mm 66 Nerve and tendon hook 16 cms length 7 mm wide semi circular curved blunt tip 67 Adson dura and nerve hook Right angled end blunt tip Length 19 cms blunt tip 68 Malleable retractors Stomach amp Ribbon retractors malleable stainless steel intestinal spatulas 12 mm width 20 cms length Ochsner ribbon retractors malleable stainless steel 30 mm width 33 cms length 50 mm width 33 cms length 75 mm width 33 cms length 69 Sargent abdominal spatula All sizes 70 Volkmann hand retractors 2 prongs semi sharp blade 8 5x8 mm 3 prongs semi sharp blade 8 5x 13 mm 4 prongs semi sharp blade 8 5x19 mm 71 Harrington retractor Blades 123x45 mm Blades 123x64 mm 72 Allison lung spatula 40 mm blade width 255 mm length 54 mm blade width 320 mm length 73 Morris retractor Total length 24 5 cms Blade 70 x 50 mm Blade 70 x 65 74 Doyen retractors for deep pelvic Length 24 cms surgery Blades 35 mm wide 90 mm deep Blade 4
164. the most demanding HPLC applications Solvent Delivery Modules to deliver highly reproducible results over a wide range of flow rates Built in time events to allow contact closure of external devices such as column switching valves The system should be upgradable for Micro and semi micro The solvent delivery system should have following technical features Flow Accuracy 2 uL 0 01 to 0 10 mL min 2 0 101 to 8 000 mL min Flow Precision 0 075 RSD Flow rate range 0 001 to 9 999 mL min Composition range 0 to 100 0 1 increments with CDS 1 increments with front panel control Composition Accuracy 196 Composition Precision 0 1 RSD System should have organizer for power supply and High gradient kit UV Vis Detector with superior signal to noise even at the fasted response times and a selection of flow cells make the for different application Advanced optics and active electronics combine to provide a new level of performance for UV and UV Vis detection Pre aligned flow cell options to access from the front of the instrument to allow the user to easily switch from micro bore to conventional or high throughput Active noise filters for a wide range of response times produce superior signal to nose while maintaining peak shape in high flow rate applications Automatic wavelength calibration and documentation to to comply with government regulations for system suitability Should be Available with a wide range
165. themselves or him their authorized agent on his their behalf In case the tender is signed by the agent the authority letter in his favour shall be enclosed with tender documents Sealed Tenders should be submitted in two bid system in two identical copies consisting earnest money technical offer amp price bid In case of equipments tender the Earnest Money and Technical Bid shall be submitted in first part while price bid be submitted in second part both separately sealed The tenderers should take care that the rates and amounts are written in such a way that interpolation is not possible No blank space should be left which would otherwise make the tender liable for rejection Delivery schedule with definite date of delivery at destination taking into congnizance of transit facilities must be indicated This contractual delivery date period should be inclusive of all the lead time The tenderers should clearly state whether he they are manufacturer accredited agents or sole representative indicating ther name of Principal on the top of the Bid The tenderers submitting his their tender would be deemed to have considered and accepted all the terms and conditions No Equiries verbal or written shall be entertained in respect of acceptance or rejection of the tender The quantity shown in the Schedule may be increase or decrease on any extent depending upon the actual requirement The tenderer shall specify after sales services facilities within the
166. tor SGPGIMS Lucknow Bids will be opened in the presence of authorized representative of the bidders on scheduled date amp time If any working day is observed as holiday the next working day will be treated as last date In case any legal dispute the legal jurisdiction shall be court of law at Lucknow responsible any postal delay The Director reserves the right to accept or reject any tender in part or full without assigning any reason thereof The Institute will not be Director SANJAY GANDHI POST GRADUATE INSTITUTE OF MEDICAL SCIENCES RAEBARELY ROAD LUCKNOW 226 014 TENDER DOCUMENTS GENERAL TERMS amp CONDITIONS FOR NOTICE INVITING The following terms amp conditions should be compiled with while submitting tender 1 10 11 12 13 14 15 16 17 18 19 Tender should be submitted to the RSD Cell Located at 3 Floor of the Administrative Building Sanjay Gandhi Post Graduate Institute of Medical Sciences Raebareli Road Lucknow 226014 INDIA Under the sealed cover failing which the tender shall be disqualified The tender terms and conditions be clearly typed or legible written giving the full name and address of the tenderers The tenderers should quote in figures as well as in words the rates and amount tendered by him them Alteration if any unless legible attested by the tenderers with their full signature shall invalidate the tender The tender should be signed by the tenderers himself
167. trolled Temperature range 40 and 120 C Temperature warning LED or Sound 1 5 C deviation Temperature Sensor Platinum resistance element Temperature display Digital LCD 0 1 C resolution Vertical freezing Internal Programs Maximum number of Fixed programs 16 nos Duration of Programs no limit Power Consumption less than 60watt Standard Cryo Chamber Capacity 23 straws 0 5cc or 46 straws 0 25cc No ICSI amp ASSISTED HATCHING INSTRUMENTS 15 Inverted Microscope Inverted Microscope basic unit 100 240V 12V 100W Consisting of Lamphouse with Precentred 100W Halogen Main Body Side port Coaxial coarse Fine focus W tension adjustment with uniform light distribution T DH 100W Dia illumination Pillar Tiltable supplied with detachable condenser carrier diffuser four filter holder and field diaphragm 45mm filter slots Lamphouser Remote Cable T PS 100W Power Supply 100 240V for T DH100W Dia illumination Pillar Halogen Lamp 12 100W LL Power Cord BE 25 Inclination tube D 25 Inclination angle Turret selector incorporated B 2 5x C 0 CFI 10X W Diopter adjustment FOV 22mm CFI UW Eyepiece Guard C N6 Sextuple Nosepiece Filter 45mm NCB11 Daylight Colour Balance Filter 45mm Heat Absorbing HOFFMAN MODULATION CONTRAST SYSTEM Contrast Control Polarizer Diaphragm OBJECTIVES gt 20XF N A 0 40 W D 3 1mm amp 40X objective 7 Plan Achromat 4X Anti Fungus N A 0
168. troller Electronic temperature controller sensor platinum resistance digital indication system Timer digital time indication system Auto temperature off Overheat warning system Flickering warning inner thermister Over heat protection system Thermal lead switch Heater 240W Attachments 3 shelves 6 supports Temperature range 5 degree C to 60 degree C Reaching time to the highest temperature 20 degree C to 60 degree C about 80 mins PGIMM PM Phototherapy Unit nd is 49 Specifications of LED Phototherapy e Should have approx 18 nos high power LED e Should have Intensity gt 30 uw cm2 nm e Variation in intensity over 6 hours 1096 e Light Source Life time minimum 20 000 hr e Should have Effective Area 50 X 25 cm e Should have Audible noise lt 60dB Dimension e Cart approximately 1460 mm H X 430 mm L X 520mm D e Main 75mm H X 340 mm L X 210 mm D e Should have Electrical Leakage current 100 uA e Should have Electrical Input AC 100 240 V 50 60 Hz e Should have Electrical Consumption about 80 VA e Should have CE Certification e Should have height adjustment e Should have temperature adjustment e CED based phototherapy for newborn using 18 high power LED sources in the range 460 480 nm and having output intensity gt 301 w cm2 nm at 45 cm e Should conform to all standard safety standards PGIMM PM Specifications for ultrasound machine for intraoperative ultrasound AN nun 0
169. ty All software up gradation should be supplied free of cost for next 5 years System CART should be of high durable quality with locking wheel device Vendor should mention the weight of the system System should have user centric control panel with home base layout and control customization System should have On Off task light and back illumination of control panel Should have thumb nail menu which provides on screen thumb nails of images and dynamic clips during exams Should have height adjustment of control panels up down with lock lever Should have multi directional articulating monitor arm to help improve ergonomics wheel lock mechanism Should have quick set vendor should quote the number of quick sets Should have 2D mode line density upto 512 lines System should have 2048 or more digital processing channels mention the number of channels and give details System should have at least 8 TGC time gain compensation more will be preferred Should have 256 gray shades or more Dynamic range should be 180 dB or more higher dynamic range would be preferred Should have a frame rate of gt 500 frames per second Please specify the frames per second in 2D mode and colour mode Higher frame rate would be preferred Should have a minimum of 4 transmit focal zones Higher focal zones will be preferred Should support broad band multi frequency probe scanning 2 18 MHz Vendor should specify the range of band width The s
170. ulator gantry inside the room and for patients along with their bed 3 New walls to be constructed for control room 4 Opening to be made in the control room wall to house the lead glass Necessary frame to fix the lead glass to be made 5 Pit to be constructed as per the requirement of the simulator base frame 6 Trenches with cover to be constructed as per the requirement of the simulator installation 7 New flooring with Marbonite Vitrified tiles to be made both in the simulator room and the control room 8 Painting to be done both in the simulator room and the control room 9 Simulator wall thickness to be of 30 cm brick Where ever necessary the thickness to be increased as per the AERB requirements 10 All the windows to be closed with 30 cm brick wall 11 If any beams are required in ceiling to be provided for the simulator installation 12 Lead Glass to be provided 13 Roof existing ceiling cleaned painted and with new lights and switches 14 The main entrance door and the control room entrance door to be of Lead lining as per AERB specification 15 False roof to be replaced with gypsum boards which are easily removable for maintenance These need to be housed in the aluminum frames with necessary AC diffusers and return vents to be provided AIR CONDITIONER 1 Appropriate number of air conditioners to be provided and installed in the simulator room and the control console area The maintenance of these will be
171. uld have space for holding and transporting approximate 150 200 kg of waste food material in plastic drums having heavy duty wheels so as to play on mettled roads PGI MM PM SSY 09 10 C 1 43 Exhaust hood Fabricated from GI sheet over MS frame provided with grease filters with multiple layer of different meshes of wire gauge in corrugated shape PGI MM PM SSY 09 10 C 1 44 Miscellaneous Kitchen equipment a LPG cylinder transport trolley for transportation of LPG cylinders domestic as well as commercial the trolley should be having space for holding and transporting a single unit heavy duty wheels so as to ply on mettled roads b Weighing scale dial type 100 kg capacity The frame livers and platform made up for stainless steel size 24x24 minimum graduation dial chart to 100 grams c LPG operated tilling frypan of 10 lit capacity All body made up of stainless steel food grade d Mixture grinder commercial ISI with attachment or made up of stainless steel e Mixture Grinder amp juicer domestic ISI all body and attachment made up of stainless steel f Plastic crates heavy duty ISI to hold 20 25 kg perishable food items g Electrical commercial juicer all body made up for SS motor ISI for extraction of juice in bulk quantity h Food processor vegetable cutting machine all body made up of food grade SS IS electric motor cap 25 kg with slicing chopping dicing grating attachment i
172. uld mention the resolution of monitor higher resolution will be preferred Measurements calculations amp software packages System should have facility to enrol complete patient information like Name age Sex Reg No U S No type of study date hospital name text and anatomical site marking System should have multiple cursor sets on frozen live dual screen and cine playback images Minimum 8 distance measurement per screen distance measurement depth measurement from skin line angle measurement volume area and circumference ellipse trace Should autotrace measurements amp calculations including PS ED TAMx TAMn PI RI S D Time average velocity max TAV VTI acceleration deceleration flow volume Doppler angle correction Should have exhaustive software with report formats for specific measurements and calculations for abdomen adult amp paediatric obstetrics gynaecology cardiac adult pediatric cerebrovascular transcranial peripheral vascular venous thyroid urology testis orthopaedics amp intra operative imaging Should have package to calculate IMT Intima media thickness Storage amp archiving Should have internal hard drive of 160 GB or more Image storage capacity of upto 150 000 images or more Should be DIMAQ IP integrated workstation which should allow digital acquisition storage and review of complete ultrasound studies including static images and dynamic clips measurements ca
173. unting With Cover Slip Original The makler Counting Chamber should be 10 microns deep 1 sq Mm fine grid in the center subdivided into 100 squares of 0 1 x 0 1 mm each Facility for spacing to be secured by quartz pins 3 Indian make Laminar Flow Unit Clean Air Equipment For 1 No Andrology VERTICAL DOWN FLOW SYSTEM Size 2 x 2 x 2ft Cleanliness Class 100 Particle Retention 0 3 Micron amp Above Noise Level 60 65 decibels A With Power Input 230V Ac 50Hz 4 Centrifuge 1 No with digital speed amp time indicator Adapter for 13ml round bottom tube 5 Digital Cell Transporter with Steel body Heating Block Dry 2 No Bath for heating of test tubes in removable autoclavable anodized aluminium blocks for maintenance of required temp Digital display amp control of temp With 0 2 C accuracy from ambient to 110 C Anodized blocks of 75X50X50mm to accommodate 12x13ml amp 12 x 6ml Tubes 6 Air Jacketed CO2 Incubator with FP IR Sensor 2 No Features Capacity 150 Litres with inner seamless chamber Inner Glass Doors to save loss of CO2 gas System to achieve Maximum relative Humidity and Dry Inner Walls Stainless steel interior Fan Free Interior Prevents building up of Germs Perforated Shelves for uniform heat distribution LCD LED Display Hot Air Auto Sterilization above 180 C Data logging facility IVF INSTRUMENTS 7 Work Station Imported for IVF Laboratory Vertical Flow I No with Complete wit
174. ve AMC charges should also be offered e The firms to give installation requirement for the equipment in their technical officer PGI MM PM SSY 09 10 N B 42 Bilirubinometer Specifications Analyses bilirubin in sample of blood taken in a micro capillary Sample volume required lt 70 microlitres Measurement system photometric double beam Reading time 3 secs Detectors silicon photodiodes Optical filters 450 575 nm Data storage last 1000 readings Results On LCD display amp printers PGI MM PM SSY 09 10 N B 43 Pediatric resuscitation kit Specifications Ambu bags 250 ml 500ml 1600ml Self inflating silicon resuscitation bags with facilities to DIRECTLY connect Oxygen Reservoir The bag is provided with spring loaded Pop off valve set to 35 40 cms of water pressure Mask sizes 00 01 and 02 Laryngoscopes with blades Blades Straight 0 1 size Miller Curved 2 4 5 Mac Guedal airways 000 0 1 2 3 Pediatric Stethoscopes PGI MM PM SSY 09 10 N B 44 PGI MM PM SSY 09 10 N B 46 Oxygen hoods Specifications Sizes Neonatal Infant Pediatric Single piece unbreakable polycarbonate 3mm thickness min autoclavable Oxygen Hood with humidification port and silicon autoclavable flap for neck height adjustment CE Certified Infant transport trolley Specifications Mobile trolley with 4 swivel castor wheels Transparent side panels with hinges Bed
175. ve electric leg operating for reduced moving amp handling risks Should have both electric amp manual emergency lowering system for emergency conditions Should have emergency stop switch to immobilize hoist in emergency Rears castors should be equipped with brakes Should have 2 10 cm and 2 7 5 cm castors for excellent maneuverability Should have following technical features Overall Width Leg Opened 110 to 115 cm Leg closed 55 to 60 cm Lift range 50 160 cm or better Safe Working load min 150 kg Should meet international quality directives such as CE ISO 9001 amp ISO 14001 Should be supplied complete with a General purpose sling with head support b Toilet sling c Neck roll sling d Long seat sling PGI MM PMS SY 09 10 N B 106 Laparoscopic Equipments 3 Optic Chain Camera High definition 3 chip camera Medical grade digital 3 chip camera Horizontal resolution gt 1100 lines SXGA technology 1280 X 1024 3 93 million pixels Progressive scan technology not interlaced In built 16 steps digital enhancer 1 3 interline transfer Hyper HAD CCD Electronically controlled digital zoom Remote control on camera head to control four step gain zoom amp white balance controls Graphic disply of activated functions Automatic brightness control Multiple pure digital output Signal to noise ratio of 70 dB Electronic flexible scopes filer to adapt with flexible scopes Standard a
176. with high precision quality with CE TUV or ISO 9002 certification All instruments should have it s own carrying case which should be autoclaveable set of disposable blades EE Specifications for Nano drop Spectrophotometer 1 DNA RNA Protein estimation 10 C 1 77 Cuvetteless optical fibre based spectrophotometer for full range UV visible spectrophotometry Xenon flash lamp Wavelength range 220 750 nm Absorption precision 0 003 PGIMM PM Specifications for Temporary Pacing box d us Dual chamber pacing with all the modes of pacing available Battery operated With connecting cable for external amp internal pacing leads PGIMM PM Steam Sterilizer Horizontal High Pressure eee High Vacuum Steam Sterilizer e QUANTITY 01 NO SPECIFICATION SIZE 24 CUBIC FEET e SHAPE HORIZONTAL RECTANGULAR e CHAMBER DIMENSION 600X900X1200 MM e STANDARD ISI AND COMPATIBLE TO INTERNATIONAL STANDARDS e CAPACITY 640 LTS e WORKING TEMPERATURE 121 C AND 134 C e WORKING PRESSURE 1 2KG CM2 TO 2 2 KG CM2 e HYDRAULIC TEST DOUBLE OF WORKING PRESSURE e Door SINGLE RADIAL ARM e CARRIAGE 1 No EACH THE STERILIZERS SHOULD BE CONFIRMING TO IS 3829 WITH ISI MARK VALID CERTIFICATE FROM ISD SUITABLE FOR STERILIZATION OF WRAPPED AND UNWRAPPED S S INSTRUMENTS amp OTHER DEVICES LINEN GLASSWARE RUBBER GOODS amp LIQUID IN OPEN BOTTLES AND CAN BE OPERATED ON BOTH STEAM FROM CENTRAL STEAM FACILITY AND INBUILT STEAM GEN
177. working height amp for tub into a platform Shower trolley should be helpful for bathing all physically handicapped patients The trolley should have total capacity of 120 liters The total length of 2 mtrs with maximum height of 940 mm Should be moving on castors with arrangement of stopping Should be electrically operated PGI MM PM SSY 09 10 N B 74 Basic Plastic Surgery Set Specification This will include general plastic surgery instruments and instruments for specialized surgery 1 General Instrument Set GENERAL INSTRUMENTS MAIER POLYPUS FORCEPS WITH RATCHET CVD BACKHAUS TOWEL HOLDING FORCEPS 110MM TOWEL CLAMP 115 MM LENGTH SCALPEL HANDLE NO 3 IRIS AND LIGATURE SCISSORS STR 110 MM KILNER DISSECTING SCISSORS 150 MM REYNOLDS SCISSORS CVD 175 MM DISSECT SCISS METZENBAUM 145MM CVD DURO DISSECT SCISS METZENBAUM 180 CVD DUROTP DUROTIP LIGATURE SCISSORS 180MM LONG DUROTIP DISS SCISS MAYO LEXER CVD 165MM OP SCISSORS STR BL SH 145 MM S DISSECTING FORCEPS SLEND PATT 145 MM ADSON FORCEPS FINE SERRATED JAWS 120MM ADSON FORCEPS 1X2 TEETH 120 MM NON TRAUMATIC VESSEL FORCEPS 150 MM TISSUE FORCEPS AM PATT 1X2 T 145MM BABY MOSQUITO ARTERY FORCEPS CVD 100MM MICRO HALSTED HEMOST FORC CVD 125 MM MICRO MOSQUITO FORCEPS STRAIGHT 1X2 T KOCHER FORCEPS STR 1X2 TEETH 140MM PEAN ARTERY FORCEPS STRAIGHT 140 MM POLYPUS A SPONGE A DRESSING FORC 175MM CZERNY TUMOR FORCEP
178. xamination Light 4000 00 16 11 09 at 04 00 18 11 09 at p m 11 00AM 3 PGI MM PMSSY 09 10 N B 13 Obstetrics Delivery Table 2500 00 16 11 09 at 04 00 18 11 09 at p m 11 00AM 4 PGI MM PMSSY 09 10 N B 14 Delivery Bed 4000 00 16 11 09 at 04 00 18 11 09 at p m 11 00AM 5 PGI MM PMSSY 09 10 N B 15 Mobile Halogen Light 1500 00 16 11 09 at 04 00 18 11 09 at p m 11 00AM 6 PGI MM PMSSY 09 10 N B 16 Cardiotocography Machine 1000 00 16 11 09 at 04 00 18 11 09 at p m 11 00AM 7 PGI MM PMSSY 09 10 N B 17 Maternal amp Fetal Monitor 1500 00 16 11 09 at 04 00 18 11 09 at p m 11 00AM 8 PGI MM PMSSY 09 10 N B 18 Portable Fetal Doppler 1000 00 16 11 09 at 04 00 18 11 09 at p m 11 00AM 9 PGI MM PMSSY 09 10 N B 19 Equipments of IVF 65000 00 16 11 09 at 04 00 18 11 09 at p m 11 00AM 10 PGI MM PMSSY 09 10 N B 20 4 D Ultrasound 20000 00 16 11 09 at 04 00 18 11 09 at p m 11 00AM 11 PGI MM PMSSY 09 10 N B 21 2 D Ultrasound 7500 00 16 11 09 at 04 00 18 11 09 at p m 11 00AM 12 PGI MM PMSSY 09 10 N B 22 Compound Analyzer 18000 00 16 11 09 at 04 00 18 11 09 at p m 11 00AM 13 PGI MM PMSSY 09 10 N B 23 Flexible Fetoscopy 7500 00 16 11 09 at 04 00 18 11 09 at p m 11 00AM 14 PGI MM PMSSY 09 10 N B 24 Surgical Instruments For Maternal amp 20 000 00 16 11 09 at 04 00 18 11 09 at Reproductive Health p m 11 00AM 15 PGI MM PMSSY 09 10 N B 25 Baby Weighing Machine Electronic 1000 00 16 11 09 at 04 00 18 11 09 at p m 11
179. ystem should be able to capture all frequency in single probe without the need for user selection System should have a high PRF pulse repetition frequency ranging from 2 15 Should have automatic quantification of Doppler parameters to display user selected measurements Should have 2D imaging depth of at least 28 cms more will be preferred System should have Tissue Harmonic Imaging THI with all transducers Please specify the harmonic frequencies System should have facility for 3D Gray with MPR for convex and endo cavitary probe Should have facility for real time compound imaging preferably with all transducers Power Doppler angio imaging for perfusion studies should be available for visualization of flow in small vessels Should have trapezoidal imaging amp steerable imaging for 2D color and Doppler with linear probe Should have tissue specific pre sets for individual clinical applications presets should be compatible with multiple probes Should have multi view spatial compounding Pan amp Zoom facility with high resolution results in both live and frozen images with facility for pre amp post processing with cine loop review in all modes should have a min 1x6 times zoom facility Vendor should specify the zoom capacity System should have scrolling facility in basic amp zoom images Cine loop facility frame by frame and in cine mode with a memory of at least 2000 2D colour images review and at least 60 seconds or more of Dopp
180. zenbaum scissors diameter 5 mm Micro hook scissors rotating diameter 3 mm amp 5mm connector pin for unipolar coagulation single action jaws Kelly dissecting amp grasping forceps Diameter 3mm amp 5 mm double action jaws connector pin for unipolar coagulation handle without ratchet Maryland dissector grasping amp dissecting forceps curved with fine horizontal serrations double action jaws diameter 5 mm Reddick amp Olsen dissecting amp grasping forceps Diameter 3 mm and 5 mm connector pin for unipolar coagulation heavy double action jaws handle without ratchet Right angled dissecting amp grasping forceps Diameter 3 mm and 5 mm Bowel grasping forceps with ratchet Fine atraumatic serrations single action jaws fenestrated Diameter 3mm and 5 mm hemostat style ratchet Babcock grasping forceps Atraumatic fenestrated diameter 3mm amp 5 mm DeBakeys grasping forceps diameter size 3 mm amp 5 mm Coagulating and dissecting electrode L shaped insulated with connector pin for unipolar coagulation Diameter 3 mm and 5 mm Dissecting spatula blunt coagulating amp dissecting electrode with connector pin for unipolar coagulation diameter 5 mm Needle holder Straight handle with ratchet diameter 3 mm amp 5 mm Suction amp irrigation tube with 2 way stopcock Diameter 3 mm amp 5mm Suction amp coagulation cannula with trumpet valve size 3 mm insulated with connector pin for coagulation Singl