Automated Characterization Suite (ACS) Basic
Contents
1. TSP Link subordinates ni Agilent 4284 CV Meter GPIB and LAN cannot be used simultaneously 8 Copyright 2011 Keithley Instruments ine Installation NOTE Before installing ACS software on a computer read and complete all of the pre installation requirements listed in the Installation section of the ACS Reference Manual ACS software comes with an installation option that allows you to generate a 30 day temporary license for quick installation of the software in the field For complete ACS software installation requirements and instructions including detailed licensing information refer to the Installation section of the ACS Reference Manual Version 4 4 release Enhancements Added Windows 7 x86 32 bit and Windows 7 x64 64 bit operating system support Enhanced modules to include the 2600 based RTM for HCI Fast NBTI TDDB_CVS VRamp JRamp Iso_EM and Poly_Heater PA 1008 Rev G Dec 2011 3 Automated Characterization Suite ACS Release Notes Added the Wafer Level Reliability Test and ACS 2600 RTM Manual in ACS v4 4 Removed the default password ACSADMIN and there is no default password for ACS V4 4 Added the JRamp and TDDB test modules that support linear time log time and Vgate shift for data compression Updated BTI projects to support a total of six PMUs for KTE v8 2 Added the Stop on Compliance function for the 2600ITM 4200ITM and mixed model SMU ITM Added 32 pin devices for the 2600 based RTM tes
2. 3 Set the value to 1 to enable the beeper set the value to 0 to disable the beeper 4 Save the file and the configuration is effective immediately Within the BTI Project and its corresponding modules the maximum segment number per channel is 2048 If you receive a dll conflict error during ACS installation shutdown the UTMServer or the KTMServer If they exist in the task manager then click Retry to continue the installation If you uninstall or reinstall KITE or GPIB drivers after ACS has been installed ACS may not function due to dll errors To resolve this issue you will need to reinstall ACS If you uninstall the NI driver and software you must reinstall ACS The diagnostic row column mode has a conflict with the Model 7072HV card because the card contains isolated rows A B and C H They cannot be connected together If you want to use the Model 4200 ITM or Model 4200 CVU the version of KXCI must be v8 1 or newer On the Model 4200 SCS instrument if you run a PTM immediately after running an ITM for the Model 4200 SCS you will need to add the statement Get4200HWCtrl to get control of statements in the module The GetHWCtrl is in the ACS_ PostData module On the Model 4200 SCS instrument if you stop a test and the LED stays on you will need to close ACS and reset the hardware in CMD line run resethw for the Model 4200 SCS then restart ACS PA 1008 Rev G Dec 2011 23 Automated Characterization Suite ACS R
3. Log into new user account Ensure you have C access rights NOTE this only applies windows limited users without C access rights Run Initialize New User tool from Start gt Program gt ACS X X Reboot you computer after initialize user finished Launch ACS 5 The problem may cause by other software with common dll file The other error in kits exe log as below Traceback most recent call last File kits py line 24 in File hardwareinteg pyc line 31 in File ACSLPT pyc line 3 in File KILPT pyc line 12 in File KILPT pyc line 10 in__load ImportError DLL load failed with error code 193 xxx Go to C S4200 sys bin directory and check if the command dll exists Search command dll in C disk and ensure without multi common dll file exists Go to My Computer gt Properties gt Advance page click user environment button to open environment dialog the following S4200 related path value should exist in path Path C S4200 sys bin C S4200 kiuser usrlib C S4200 sys openint dll Click ok button and launch ACS the problem will be solved 2 ACS fails to launch Only a kits exe log file is generated Launch ACS the error occurrs and a kits exe log file is generated in C ACS KATS 16 PA 1008 Rev G Dec 2011 Automated Characterization Suite ACS Release Notes The error in kits exe log is as below Traceback most recent call last File kits py line 24 in File hardwareinteg pyc li
4. hang problem Enabled the NBTI supporting TAR_IATV Enabled the NBTI supporting VTCI_LOG10 Disabled the General Purpose Instrument to follow matrix Common LO Independent LO scheme Added a Qbd log stress value as attribute Repaired the ACS data disappearing in trial operation problem Repaired the ACS wafer level plot problem Added a function to find out Qbd breakdown in ACS and KDAT Added a breakdown judgment to limit lowest voltage in JRamp Enabled the Chuck_Force items in 3730 column 10 PA 1008 Rev G Dec 2011 Automated Characterization Suite ACS Release Notes Repaired the 237 is not recognize after configure Hardware problem Repaired the axis title and axis values over lap if more than 1 plot problem Added an error checking for Groups and associated SMU s Added a bsweep Python lpt for 4200 Enabled the 2410 over temperature error displayed in ACS Repaired the prober button is masked by abort operation problem Removed the cassette map information in the project Enabled the writing data to kdf after each device Known issues The KI2651A instrument model is not supported within an ITM and 2600 based RTMs In Windows 7 operating system you will need to keep the network cable plugged in if you are using a license file If the network cable is removed ACS consider your license file invalid In Windows 7 operating system when you install software or update the USB license key you may encounter a Use
5. that ACS softeare causes for instruments if KITE goes offline Repaired the Python getcommon command so that it includes system attributes Repaired the conpth and conpin commands to allow for dangerous connections 6 PA 1008 Rev G Dec 2011 Automated Characterization Suite ACS Release Notes Repaired the Fast NBTI spiking and hanging problem Repaired the ISO_EM test so that it will not stop before meeting any failure criteria Enhanced the SWEAT output file Added a prompt continue or stop dialog box if a prober error occurs Non critical fixes The kdf and db file configurations depend on the project instead of the platform The VRamp function allows you to set the real time post data condition for example the time to post and the data points to post Added an upgrade plot setting checkbox in the preference settings If selected it will update lines when the axis settings change Added the ability for ACS to generate temporary files at all times for your reference if needed Saving CSV file related optimization 1 Optimized memory management and enhanced manual run to saving csv file 2 Optimized memory management and speed up saving automation csv file 3 Changed saving automation csv files from kdf folder to csv folder 4 Changed automation csv files saving configuration from KATS_Pref ini to project the settings will bound with project 5 Added basic test information into the header of csv file includin
6. 00 SCS 5 Installing new version of ACS after ACS is installed restore user projects libraries etc from ACSx x_old if need NOTE After new version of ACS updating you still can perform the following operations to launch earlier version of ACS 1 Goto the C ACS directory and rename it to c ACS_new 2 Go to the C ACSx x_old directory and rename it to c ACS 3 Launch ACS earlier version of ACS should start You can perform the adverse above steps to launch new version of ACS TEquipment An Interworld Highway LLC Company 140 PA 1008 Rev G Dec 2011 Automated Characterization Suite ACS Release Notes Troubleshooting ACS NOTE You may choose following one of case or some cases to perform the operations to solve the problem 1 Common dil error and ACS cannot launch When start ACS the Command dll error will popup and the kits exe log file will generate in C ACS KATS The error in kits exe log as below Traceback most recent call last File kits py line 25 in File hardwareinteg pyc line 44 in File ACSLPT pyc line 6 in File KIGPIB_KATS pyc line 12 in File KIGPIB_KATS pyc line 10 in__load ImportError DLL load failed The specified module could not be found 1 The problem may be caused if the user does not reboot after installation of ACS Reboot your computer Launch ACS 2 The problem may cause by reinstalling KTEI Check the C S4200 directory The C S4200 directory should no
7. 011 Automated Characterization Suite ACS Release Notes The Script Editor allows a default value for a string input variable Statistics was updated to allow selectable expression formats on a wafer map Statistics was updated for the scale property and now can be saved or loaded Statistics was updated to allow manual scale settings in the Histogram Statistics was updated to allow indication lines on the Histogram and CDF Added a file overwrite confirmation to the ACS Summary Report section Critical fixes CVU test and HV Model 2410 are supported in confidence check testing for the S530 System only Added support for both All wafer and Random wafer on P8 prober Statistics added Histogram and CDF comparison Script Editor added LUA compile tool to support the TSP syntax error check feature Made user password encrypted and added a dialog box for password management Updated the KTMServer exe file with a pcivpureset function call to fix the BTI abort issue Added select or de select option on the Preference dialog box to redirect prober status to log Window Updated the diagCVU with new KXCI communication function Diagnostic testing added a retest or continue feature if testing fails ACS now can poll the Prober for if there is a realign error Non critical fixes Interlock check added in 24lpt sweep bsweep asweep function after output on and every 0 5s Added the Model 707B 708B Reference manual to the Help drop down menu A
8. ACS Release Notes Repaired prb_error UAP was not working Non critical fixes Removed the password display in user account dialog box Added dialog box for password management will not show content of any password Improved operator security Version 4 2 release Enhancements ACS installation enhancement minimize overwrite of KITE files and synchronize prober drivers with KITE 530 enhancements include confidence check diagnostic CVU and calibration verification ACS performance optimization includes start load project start automation and data handling Added debug tools capability for Python modules Hardware configuration updated for scanning Model 3401 3402 Critical fixes Diagnostic support for the SS30HV Kelvin mode Confidence check support for the SS30HV Kelvin mode Added Python LPT for the Series 2600A and 2400 instruments bsweepi bsweepv trigcomp trigig trigil trigvg trigvl Non critical fixes Updated ACS to support Windows XP multiple users added Initialize User in Start gt Programs gt ACS 4 2 First you will need to create a new user account that has rights to the registry table Then you will need to click the menu in the new user account and restart your PC ACS will then work for multiple logins to the Windows XP environment Made a S530 enhancement for CVU added CpGp through the switch compensation example project You can find it in the following folder location ACS projects CVU_C
9. Automated Characterization Suite ACS Keithley Instruments Inc Release Notes 28775 Aurora Road Cleveland Ohio 44139 1 888 KEITHLEY ss www keithley com quipm u ip me nt General information eNET An Interworld Highway LLC Compan Overview g x PARY The Keithley Instruments Automated Characterization Suite ACS software supports component characterization testing of packaged parts and wafer level testing using a manual probe station ACS software can be installed on any computer or Keithley Instruments Model 4200 Semiconductor Characterization System 4200 SCS with a Microsoft Windows XP Professional Service Pack 3 SP3 or Windows 7 x 86 32 bit or Windows 7 x 64 64 bit operating system Supported models and test configurations NOTE Before you install ACS software on a computer read and complete all of the pre installation requirements listed in the Installation section of the Automated Characterization Suite ACS Reference Manual document number ACS 901 01 This manual is provided in PDF format on your ACS Software CD ROM CD number ACS 950 01 The ACS software can be used with the following Keithley Instruments models in several different testing configurations e Perform multi group testing of Series 2600A System SourceMeter instruments using ACS software installed on a personal computer or laptop e Control Model 4200 SCS Semiconductor Characterization System hardware using ACS software installed on t
10. B_ERR to obtain the prober error code and prober error message designed to use in prb_err_hdlr UAP Opened formula for end user the path to the formula is library ExtLibrary The ACS append mode was increased to default at 30 Added invalid project name check for Save As and Save As Template dialog Added time register in Exception file The project file option only lists the available projects for the operator end user Added an option to the Preferences dialog box to select or de select prober status Built in the latest version of the KXCI client tools End user is not able to override Auto Test information with the FUNC_SET GLOBAL_VALUE UAP in automation_begin In limit sheet setting the report flag will affect the data output into KDF file Added the UAP_VALIDATE_OCR to correct wafer id Added the directory location of the kdf files to the Preferences dialog box Added compliance status checking function in the Python LPT for Series 2600A instruments Added S400 LPTLIB functions that are available on S530 Parametric Test System for example searchX that are compatible with the S400 LPTLIB commands Added the S400 and S600 LPTLIB function rt fary to the STM and PTM LPTLIB commands Added python LPTLIB command support for the sweepv and smeasz functions for the Model 4200 CVU In the Script Editor removed the import library function You will have to load the library from the library drop down menu 20 PA 1008 Rev G Dec 2
11. ame folders where your ACS project files are kept If you have questions or need further assistance contact Keithley Instruments at 1 888 KEITHLEY 534 8453 U S only or send email to info keithley com 28 TEquipment An Interworld Highway LLC Company PA 1008 Rev G Dec 2011
12. aved into a plain text file txt e A system verification project can be opened from the help menu with connection information in an accompanying PDF e CV KI237 KI23X Kl24XX KI37XX and SWITCH libraries are supported 2 PA 1008 Rev G Dec 2011 Automated Characterization Suite ACS Release Notes ACS Features and Support SMUs KEITHLEY CONFIDENTIAL PROPRIETARY A GREATER MEASURE OF CONFIDENC www kelthliey com Overview ACS Features and Supported SMUs Instruments a ACS Feature i Nein OLeS ip 9 x S Automatic hardware scan Model 237 must be added a as an extemal and configuration instrument Includes built in test libraries for a variety of hey yet devices gt Specific test module with interactive style J y J J that allows user to use different series of General Purpose PTM SMuUs to build a custom test There are two kinds of CTM ACS Classic Style only contains one test module and Advanced Style Support CTM List Can write scripts to achieve maximum speed from TSP enabled instruments Includes built in test libraries for a variety of devices supports LPT commands Includes HCI Fast NBTI TDDB_CVS Vramp ACS 2600 RTM x NI y x X Jramp lso_EM and Poly Heater modules ACS also supports these ACS supports these instruments communication interfaces Keithley 4200 CVU GPIB NI and Keithley cards only Keithley 707 8A B switches LAN Keithley 3700 Switch DMM
13. cause the software to not function properly You can change the timer interval if needed in the ACS_ setting ini file ACS does not support mixing Series 2600A instruments with Series 2600 instruments with the DTNS operation which includes RTM parallel modules When AGS is installed on the Model 4200 SCS and KITE is upgraded to v8 1 you must delete the ieee_32m dil file in the following location C windows system32 Once deleted you must reinstall the CEC488 GPIB driver v8 2 If you ever encounter an error go to the Help drop down in ACS and select Trouble Shooting then click Zip Support Info The Zip file will be saved to the following location ACS KATS support_info Next send the information file by e mail to the following address info keithley com ACS only supports the English language Errors may occur when saving and opening ACS files if characters from other languages are within the names of directories on the computer Version 4 2 5 release Critical fixes Supports 530 full Kelvin configuration Repaired BTI real time data back issue using banding sequences Repaired limitation issue in GUI list in BTI Repaired pre test and post test inter stress exception issue in BTI Repaired double pattern created in S900 conversion Repaired import WDF problem ACS build incorporated latest KTEI version upgraded to Visual Studio 2010 cleaned up unneeded files 24 PA 1008 Rev G Dec 2011 Automated Characterization Suite
14. ct File will fail you will receive an error In addition the devices imported will appear incorrectly By default the beeper is disabled when executing a module If you want to disable enable the beeper when running a module refer to the following steps 1 Open the file ACS_setting ini in the KATS folder in the ACS file directory 2 Find enable that is under the item beeper beeper gt enable 3 Set the value to 1 to enable the beeper set the value to 0 to disable the beeper 4 Save the file and the configuration is effective immediately Within the BTI Project and its corresponding modules the maximum segment number per channel is 2048 If you receive a dll conflict error during ACS installation shutdown the UTMServer or the KTMServer If they exist in the task manager then click Retry to continue the installation If you uninstall or reinstall KITE or GPIB drivers after ACS has been installed ACS may not function due to dll errors To resolve this issue you will need to reinstall ACS If you uninstall the NI driver and software you must reinstall ACS If you want to use the Model 4200 ITM or Model 4200 CVU the version of KXCI must be v8 1 or newer On the Model 4200 SCS instrument if you run a PTM immediately after running an ITM for the Model 4200 SCS you will need to add the statement Get4200HWCtrl to get control of statements in the module The GetHWCtrl is in the ACS_ PostData module On the Mod
15. d the FS NBTI and add limit to prevent multiple sweeps Updated the FS NBTI GUI checks when no terminal is selected for measurement Repaired the FS NBTI so that parallel mode can be selected for the RTM Repaired the FS NBTI so that the Apply to All function works correctly Improved ACS v4 1 wdf file to increase the speed of loading Provided an up and down option for node in the test tree Added the default to disable beep when executing a module Repaired the deleted module in Script Editor so that it is refreshed in the test setup Improved start ACS after set pseudo card of Model 3706 Improved the ability to show the whole test name in the basic monitor items in automation Added capability for ACS to automatically scale graphs on the graph sheet Improved the axis settings so that the minimum and maximum entry is loaded with the Auto Scale Values Improved the converting a S900 S400 S600 CPF so continue process if error occurs Improved the addcon command with the Model 3706 and instruments connected to rows and pins to column Repaired the CVU so that it cannot be connected by the switch control LPT Improved ITM to reduce errors when conducting many samples in a test or using Ethernet communications Changed the settings so that you cannot change some default values in the automation settings in order to prevent unnecessary errors in your tests Version 4 1 release Enhancements This is the baseline release of ACS softwar
16. dded an ACS Programmer s Manual that includes ACS Global Variables and Functions under the Help drop down menu Add 530 Documentation S530 Administrative Guide S530 Diagnostics Manual under Help drop down menu Added project name FACTORY_UTP_CHECKOUT to the ACS project folder The project will be used by manufacturing to perform the final checkout burn in of all S530 systems Added a prompt to continue or stop dialog box if a prober error occurs RPM After switch to DC mode call devclr to clear output PA 1008 Rev G Dec 2011 21 Automated Characterization Suite ACS Release Notes Updated the installation register key to solve wrong sampling time Changed the ACS evaluation license period from two days to 30 days Changed the System Information menu to Trouble Shooting Included a zipped support file that includes all the necessary files for troubleshooting Repaired the ACS csv file output that did not support subsite x Repaired SMU2 and SMU3 on a single Model 2635A that did not force a bias voltage The ACS Script Editor Save icon is disabled Repaired the ACS GeneralTestLib hung automation if it has sweep with step Repaired the ACS Script Editor to add extraneous end statements to the TSP modules Repaired the ACS GeneralTestLib trigger overrun Repaired the vertical toolbar that was truncated on the test setup panel Repaired the Script Editor error when inputting digits to str type Repaired errors that occur
17. e version 4 0 Critical fixes There were no critical fixes included in this release See the Known issues topic for more information about release content PA 1008 Rev G Dec 2011 27 Automated Characterization Suite ACS Release Notes Non critical fixes There were no non critical fixes included in this release See the Known issues topic for more information about release content Known issues Using KITE software version 7 0 with Model 4200 SCS ITMs If you install KITE software version 7 0 and want to use a Model 4200 SCS interactive test module ITM make sure you have the newest version of the kxci_patch files in your S4200 folders Compare the dates of the kxci_patch files located in the ACS KATS folder with kxci_patch files in the following folders e 4200 sys bin e S 4200 sys include e 4200 sys lib If any of the files in the S4200 folders are older than the file in the ACS KATS folder replace them with the newer file Running a PTM after an ITM on a Model 4200 SCS To run a Python programming language test module PTM after running an ITM on a Model 4200 SCS you must add the Get 4200HWCtr1 statement to the ACS_PostData module before any statements in the PTM to get control of the hardware English language requirement in project folders ACS software only supports the English language You may receive errors in your tests if you save files in other languages in the s
18. el 4200 SCS instrument if you stop a test and the LED stays on you will need to close ACS and reset the hardware in CMD line run resethw for the Model 4200 SCS then restart ACS 12 PA 1008 Rev G Dec 2011 Automated Characterization Suite ACS Release Notes On the Model 4200 SCS instrument if you do not want KXCI to start when you open and run ACS you can change the setting in the ini file to avoid unnecessary hardware conflicts You must set the start_kxci value to 0 in the ACS_setting ini file to stop KXCI from running For example if you run CTM automation and stop the test before it s finished you may need to restart ACS because of a hardware usage conflict between CTM and KXCI ACS does not support a remote connection such as a terminal server VNC Windows XP remote client etc with the USB license key If you have a requirement to use a remote connection contact Keithley Instruments Inc In a parallel 2600 based RTMs test at least one subdevice with a SMU as the master node has to be selected Since the release of ACS version 4 0 ACS will dynamically load the system script for UAP when running RTM projects If you have an older version of ACS and install a newer version you will need to delete preload all delete all and collectgarbage UAPs before running RTM projects inherited from the previous versions In the Device settings every Pad Name subdevice must have the correct format refer to the ACS Reference manual
19. elease Notes On the Model 4200 SCS instrument if you do not want KXCI to start when you open and run ACS you can change the setting in the ini file to avoid unnecessary hardware conflicts You must set the start_kxci value to 0 in the ACS_setting ini file to stop KXCI from running For example if you run CTM automation and stop the test before it s finished you may need to restart ACS because of a hardware usage conflict between CTM and KXCl ACS does not support a remote connection such as a terminal server VNC Windows XP remote client etc with the USB license key If you have a requirement to use a remote connection contact Keithley Instruments Inc In a parallel RTM test at least one subdevice with a SMU as the master node has to be selected Since the release of ACS version 4 0 ACS will dynamically load the system script for UAP when running RTM projects If you have an older version of ACS and installed a newer version you will need to delete preload all delete all and collectgarbage UAPs before running the previous version RTM projects In the Device settings every Pad Name subdevice must have the correct format refer to the ACS Reference manual for more details For a real time plot and data display if the volume of data is large it may take several seconds for the data to update or may cause the software to stop functioning For example if the real time timer interval is set to update every 1 or 2 seconds it may
20. emove previous GPIB interface Go to C WINDOWS system32 ieee_32m dll and delete it Go to C WINDOWS system32 gpib 32 dll and delete it Reinstall GPIB driver Reinstall ACS 3 Nivisv32 dll error and ACS cannot launch The problem may cause by KTE and NI software installing the Nivisv32 all and Visa32 dll version does not match The error messengers refer to as below The ordinal 126 could not be located in the dynamic library NIVISV32 dll The ordinal 18 could not be located in the dynamic library NIVISV32 dll Go to C WINDOWS system32 NiviSv32 dll and rename it Go to C WINDOWS system32 Visa32 dll and rename it Install ACS Also you can update NI Visa runtime 4 3 or higher version to solve this problem 4 LPTLIB dll error and ACS cannot launch This problem cause by KTE 6 2 or earlier KTE version is installed Updating KTE v8 1 or higher version the problem will be solved 5 ibup dll error break the ACS installing The problem may happen when you reinstall ACS Go to Windows Task Manager kill UTMserver KTMserver or Kits if exists Reinstall ACS 6 ACS cannot start cause by invalid password after ACS updating This problem may happened after you overwrite updating earlier ACS to ACS v4 3 or higher Go to C ACS KATS KATS_pref ini file and rename it to KATS_pref_old ini Start ACS login as ACSADMIN and enter the default password 7 ACS cannot scan hardware when starts Reconnect GPIB cable and TSP Link cable and resta
21. erter Repaired the issue of not being able to find 42SMUs in the ITM after setting the IP address in the Model 4200 settings Repaired the importing S4200 project issue that resulted in an incorrect device type Repaired the issue of ACS freezing when clicking on a sub site and new type of project Added a new formula to the formulator GET_LISTINDEX Added an exit button to the PTM Script Editor Repaired the formulator SS function Added a pop up window message to let you know that KITE is launching Repaired the standard CSV file output Repaired the colors in the Wafer Level Plot since they did not match the binning settings when all the sites were selected on a wafer Added support to the PTM STM and ITM for the set mode setting measure delay Improved the scanning in Model 2420 in ACS hardware configuration Made ACS login username and password case sensitive Repaired the kdf file data that is not complete in automation with CTM online mode Improved the module MDD py in order to control the matrix open or close Removed the calibration and verification functions from the preload functions and added a LoadFunc stm to the calibration and verification project 26 PA 1008 Rev G Dec 2011 Automated Characterization Suite ACS Release Notes Repaired Script Editor so that library names can start with the letter t Added support for Pattern ID so that you can log information in the log window with LogInfo Update
22. for more details For a real time plot and data display if the volume of data is large it may take several seconds for the data to update or may cause the software to stop functioning For example if the real time timer interval is set to update every 1 or 2 seconds it may cause the software to not function properly You can change the timer interval if needed in the ACS_ setting ini file ACS does not support mixing Series 2600A instruments with Series 2600 instruments with the DTNS operation which includes RTM parallel modules When AGS is installed on the Model 4200 SCS and KITE is upgraded to v8 1 you must delete the ieee_32m dil file in the following location C windows system32 Once deleted you must reinstall the CEC488 GPIB driver v8 2 If you encounter an error you need help with go to the Help gt Troubleshooting gt Zip Support Info The zipped file is saved to ACS KATS support_info Send the information file by e mail to the following address info keithley com ACS only supports the English language Errors may occur when saving and opening ACS files if characters from other languages are within the names of directories on the computer Updating ACS information NOTE If you have earlier software installed on your PC or Model 4200 SCS and you are updating to new version of ACS you can choose following one of case to perform the operations The following cases also apply to reinstall the same version of ACS Directly
23. g Lot name Wafer id Project name and Time Added the system User environment and can save in support info file Added and enabled a DMM function to the MDD py module Repaired the TSP matrix Ipt functions Chuck can be correctly connected Repaired the python matrix lpt functions 2410 SMU can be connected to multi pins now Enabled the 2400 beeper for ACS V4 4 Enabled the BTI setting stored in output files Repaired the RTM polyheater default Compl value of HeatLo Repaired the ITM that Vprog log value is rounded Repaired the Save as template that it no longer copies data folder Added an error check in HCI exit target condition value to force user input positive value PA 1008 Rev G Dec 2011 7 Automated Characterization Suite ACS Release Notes Added an error check to HCI Stress V when Stress V is nil Repaired the HCI formula for a proper definition of VTCI_LOG10 first parameter U Repaired the HCI sweep measure source range setting error when using best fix Repaired the HCI formula that can be correctly generated when changing sweep measure to sample measure Added the correct definition to SSVTCI in Data tab formulator Repaired the Formulator VTCI_LOG10 of data tab Removed the Data Tab formulator PCTSHIFT_TO Added a message when copy first to all failed in HCI Repaired the HCI GUI check for on off sequence if shared Gate Repaired the HCI amp FS_NBTI percentage shift mode that it is f
24. gs when many parameters are selected Enabled the disabled items can be selected Reworded the warning message when scan hardware Repaired the HCI NBTI and FS_NBTI insert global data error problem Repaired the Hardware tooltips that they match in hardware change info window The Login In Demo Mode checkbox is selected by default when ACS starts Added a message ACS folder already exists do you want to replace it dialog box when ACS is reinstalled PA 1008 Rev G Dec 2011 9 Automated Characterization Suite ACS Release Notes Updated the GUI for the HCI RTM Repaired the ACS4 3 Manual bug for HCI NBTI timing dialog Repaired the formulator vector functions Repaired the problems that occurred when aborting test sequences that use the PMU Repaired the array plotting from S4200Parlib to be orderly Capitalized the date Changed all Can not to Cannot Enhanced the ACS Prober Reference message Enabled the filter of 4200 ITM Changed the Delay Factor in 4200 ITM to Sweep Delay Added a status flag as result for Em_iso_test tsp Placed the bsweep trig correct place in manual Changed the note in Diagnostics module Repaired the spelling error of SLot Enabled the prober returning to the home position in single wafer mode Repaired the mismatching in cassette info Repaired the CVU locked when several times run system mode test without reset and reconnect KXCI problem Repaired the Program not responsive or
25. he Model 4200 SCS e Perform combined group testing of both Model 4200 SCS and Series 2600A instruments using the ACS software s combined test execution engine e Control other external GPIB instruments using ACS software installed on a personal computer or laptop external instruments are only controlled through a GPIB cable NOTE When using the current release of ACS on a 4200 SCS you should ensure that your 4200 SCS has KTEI V8 2 or higher installed Software compatibility You can use ACS software with Keithley Interactive Test Environment KITE software version 8 2 or later with no special configuration requirements ACS software features e Supports 2600 based RTMs includes HCI Fast NBTI TDDB_CVS VRamp JRamp Iso_EM Poly_Heater and Stress_ Migration modules Need ACS 2600 RTM package license ACS 2600 RTM is not available in ACS Standard Edition or using 30 day temporary license e Requires ACS 2600 RTM package License The 2600 based RTMs not available in ACS Standard Edition PA 1008 Rev G Dec 2011 1 Automated Characterization Suite ACS Release Notes e Added the Model 2651A instrument support When connected properly the instrument will be scanned and added automatically within the Hardware Configuration e Added 2651A sample library Sample_2651A tsp under 26 TSPLib folder e Added sample libraries projects includes 237 HV Reliability test modules Stress Migration Charge Pumping and Pulse Stres
26. in the Row Column diagnostic testing Repaired the ACS Map style that did not output a csv file Repaired the ACS ITM setting that would disengage if the subdevice was greater than 1 Repaired the Python LPT commands conpin and addcon that did not work properly for the CVU Changed the corresponding die size x and die size y concurrently if the orientation changes Repaired the ACS Weibull plot x axis if it is incorrect and does not work for the Weibull analysis Repaired the CTM run problem Repaired the RTM JRAMP memory error Enabled the RTM JRAMP frame for PLC input Disabled the RTM JRAMP limiti setting for the pre current test Repaired the ACS statistics legend overlap on the wafer Repaired the ACS Wafer Level Plot overlay issue The Script Editor was updated to add default imports Known issues If you cannot run the CTM after it has been complied by Visual Studio 2008 you will need to upgrade to NI VISA runtime version 4 6 22 PA 1008 Rev G Dec 2011 Automated Characterization Suite ACS Release Notes If any of the matrices in the system are set to Remote Sense or the S530 Kelvin mode all of the Series 2600A and Series 2400 instruments in the system will be set to four wire 4 W mode when executing a test Also the SMU Remote Sense option box in the Preference settings Misc tab will be disabled When all the matrices are set to Local Sense all of the Series 2600A and Series 2400 instruments in the system will be set
27. lay correct data after running a test and the data will get appended Repaired the VRamp so that it can return the correct data Tod when the device breaks down Repaired the VRamp return status error so that if the devices break down reaching the Qmax problem Repaired the subsite GUI so that it will display correctly after changing the subsite name and deselecting the Apply function Repaired the inability to re scan hardware due to the ACS not responding when there is a GPIB conflict Repaired ACS so that it will start if a Model 4200 is defined in the ACS preferences and there is a KXCI or other error Repaired ACS so that the configuration parameter that defines the windows directory path is missing or does not contain the paths to ndcore dll or common dll it will now start Repaired the sweep issue if the Model 237 stops running Enabled ACS so that it will run all C Test Modules CTM Repaired the PTM GUI so that it does not disappear Repaired the data output issue that affects the csv file Repaired the TDDB so that a 100pA measurement range can be used Repaired the VRamp so that SMU1 and SMU2 can ramp voltage when other SMUs finishing ramping Repaired the RTM VRamp partial data dropping problem Repaired the statistics plot zooming function Repaired the SMU Commands Calling during the CVU Test problem Repaired the FastNBTI so that the down ramp of the post test will work correctly Repaired the aborting problem
28. m Repaired the JRamp missing last points when only using Vgate shift data compression problem Disabled the auto scroll of scrollbar in GeneralTestLib Repaired the TDDB that power off and relay off can be done when subdevice failed in parallel mode Repaired the JRamp missing the last data when devices breakdown by using data compression problem Repaired the JRamp to return correct breakdown data when it is stopped by compliance Added an error check for TDDB_CVS GUI List mode with Insert every stress section should be gt 0 1s Repaired the VTISUBMAX disappeared from HCI formulator dialog problem Repaired the JRamp Sample interval for all the devices are not the same problem Added an error check for Lowest V and Max Q in JRamp panel Added an error check for PLC value in JRamp GUI Repaired the VRamp set up test module Sequential mode and Parallel mode is disabled problem Repaired the VRamp Sample interval for all the devices are not the same problem Enabled all SMUs of Group 1 can be assigned to Pad Repaired the BTI test module that if there are two formula you can change the sweep value Repaired the RTM that subdevice1 can be removed from test Repaired the devint and clrcon when using GPI and Matrix together Enabled enough digits of Compl input for HCI amp FSNBTI GUI Repaired the Formulator in offline data plotting that it has the same function of formulator in Data Tab Increased the speed when you apply the binning settin
29. ne 31 in File ACSLPT pyc line 7 in ImportError No module named ptmipt constantipt 1 The problem may be caused by pyLibrary value path error in user environment Go to My Computer gt Properties gt Advance page click user environment button to open environment dialog the pyLibrary value path should match ACS install path as below pyLibrary C ACS library pyLibrary Modify the value path and click OK button to exit user environment dialog Launch ACS 2 The problem may cause by run ACS from renamed C ACS_xx directory If you renamed C ACS_xx directory rename it back to C ACS Launch ACS from start menu or desktop icon the problem will be solved NOTE you should not double click kite exe to start ACS in KATS directory after you changed ACS directory name The other error in kits exe log as below Traceback most recent call last File kits py line 24 in File hardwareinteg pyc line 31 in File ACSLPT pyc line 3 in File KILPT pyc line 12 in File KILPT pyc line 10 in__load ImportError DLL load failed xxxxxxx 3 The problem may cause by remove or reinstall GPIB driver Go to C WINDOWS system32 ieee_32m dll and delete it Go to C WINDOWS system32 gpib 32 dll and delete it Reinstall GPIB driver Reinstall ACS PA 1008 Rev G Dec 2011 17 Automated Characterization Suite ACS Release Notes 4 The problem may cause by install multi GPIB interface or change GPIB interface R
30. on to identify Idsat in ACS 2600 RTM HCI test Added searchX function to PTM and STM Iptlib BP A 1008 Rev G Dec 2011 Automated Characterization Suite ACS Release Notes Critical fixes Updated the ACS Reference manual and created a new ACS 2600 based RTM User s manual Added pulse_remove to the ktmserver exe file to fix BTI abort issues Optimized the hardware scan using multiple threads to scan the hardware instead of a single thread Added an XY setting Valid for Series in the 2600 based RTM tests for the data plot Added expression to the HCI and Fast NBTI global variables Repaired the memory error when loading a kdf file in the wafer level plot or in statistics Repaired the JRamp problem that does not perform the ramp Repaired the ACS ITM Current Sweep setting problem Repaired the HCI measure global expression so that it can be edited without inserting a global dialog Repaired the formulator so that it can be removed for the ITM step function Repaired the ACS RTM TDDB_CVS error that occurred when the test finished Repaired the HCI and FS_NBTI tests that the fast clicking stress panel maximum recursion depth exceeded so that it will no longer cause errors Repaired the ACS RTM VRamp so that the last data sweep is correct Repaired the ACS RTM JRamp Formulator functions so that they do not diappear Repaired the ACS RTM JRamp Formulator so that the results are available after finishing the test Re
31. pGp_Compensation Disabled Preferences settings for the operator mode Incorporated an automatic copy function while ACS is installing for the KXCI patch and old KILPT dll files if KITE version is older than 7 0 Added a CSV file saving function for multiple groups in RTM test Graphically defined a new device update by adding a pad setting dialog using the matrix mode PA 1008 Rev G Dec 2011 25 Automated Characterization Suite ACS Release Notes Repaired the global variables ACS_ssite_loopNum and ACS_ ssite_loop Added support for exporting and importing a test tree pattern at the sub site or device level in Map mode project Added a default path for importing and exporting project tests in Tools gt Preferences gt Path tab C ACS Projects Updated the automation options there are three options in automation Skip 1 Wafer Load Single Wafer and Unload Wafer after test The options have been updated in order to save in individual projects after you change an option and each project has all of these options Updated the use of the USB license key so that it can be used for ACS standard and ACS Basic on the same PC Added LPT support for the Model 3401 3402 34xxlpt Repaired the RTM renaming issue Repaired the KITE issue of entering Demo mode unless ACS has launched first Repaired the missing PTM GUI after importing and switching back to the hardware configuration view Added a save new project path for the S900 conv
32. paired the Formulator function so that you can run a test on an RTM and after testing you can add another formula if needed Repaired the ACS RTM WLR Formulator so that the results will display on the data sheet Repaired the ACS RTM HCI WLR Formulator so that the results will display in the target setting Repaired the memory error when switching from the definition to the Data tab after the test has stopped Added an Invalid message that pops up when adding a new account and deleting it then restarting ACS with the user name ACSADMIN Repaired the wafer map so that updates are in real time Repaired the settings so that the loop number can be set to 0 Repaired the TDDB so that when the monitor measure takes a significant amount of time and the test cannot be stopped data for the subordinates will still be collected both GPIB and LXI PA 1008 Rev G Dec 2011 5 Automated Characterization Suite ACS Release Notes Repaired the TDDB so that when the sample interval is 1 second of Group 1 for example 1 group 4node the real time sample interval will be correctly set Repaired the HCI GUI so that the Compliance option is updated after making an edit Repaired the TDDB runtime error 286 problem Repaired the General TDDB_CVS script TSP Syntax error Repaired the ITM on the device level so that the ITM Data sheet will display the correct result Repaired the id_vg module in the default project so that the data sheet will disp
33. r Account Control UAC error If you encounter this error click the Yes button to continue and perform the following steps to turn off the UAC error 1 Go to Control Panel gt User Account and Family Safety gt User Accounts 2 Select a user then click Change User Account Control setting 3 On setting dialog move the notify slide to Never notify and click OK to save it ACS cannot scan instruments when the Series 2600A firmware is version 2 1 6 and a 2600A instrument is the master to a Model 2651A using a TSP Link cable You can refresh the 2600A firmware version to 2 1 3 or 2 1 1 to solve this issue If you have ACS v4 2 or earlier software installed on your PC and you are updating to ACS v4 4 you will need to perform the following operations first 1 Uninstall the previous version of ACS 2 Go to the C S4200 directory on your computer and rename it to C S4200_old NOTE this only applies if you are NOT installing ACS on a Model 4200 SCS 3 Remove the C ACS KATS KATS_pref ini file 4 Install ACS v4 4 If you cannot run the CTM after it has been complied by Visual Studio 2008 you will need to upgrade to NI VISA runtime version 4 6 PA 1008 Rev G Dec 2011 11 Automated Characterization Suite ACS Release Notes If any of the matrices in the system are set to Remote Sense or the S530 Kelvin mode all of the Series 2600A and Series 2400 instruments in the system will be set to four wire 4 W mode when executing a
34. rename C ACS directory recommended 1 Goto the C ACS directory and rename it to c ACSx x_old 2 Go to the C S4200 directory and rename it to C S4200_old NOTE this only applies if you are NOT installing ACS on a Model 4200 SCS 3 Install new version of ACS after ACS is installed restore user projects libraries etc from ACSx x_old if need Overwrite earlier version of ACS when updating PA 1008 Rev G Dec 2011 13 Automated Characterization Suite ACS Release Notes 1 Goto the C ACS directory and copy paste it the copy of ACS directory will be created rename copy of ACS directory to ACSx x_old 2 Go to the C S4200 directory and rename it to C S4200_old NOTE this only applies if you are NOT installing ACS on a Model 4200 SCS 3 Remove the C ACS KATS KATS_pref ini file NOTE this only applies if you have ACS v4 2 or earlier software installed and you are updating to ACS v4 3 or higher 4 Install new version of ACS Remove earlier version of ACS before updating 1 Goto the C ACS directory and copy paste it the copy of ACS directory will be created rename copy of ACS directory to ACSx x_old 2 Remove ACS from Start gt Program gt ACS X X gt Uninstall Automated Characterization Suite 3 After un install complete delete C ACS directory 4 Go to the C S4200 directory and rename it to C S4200_old NOTE this only applies if you are NOT installing ACS on a Model 42
35. rt ACS may solve this problem 18 PA 1008 Rev G Dec 2011 Automated Characterization Suite ACS Release Notes Power off and power on instruments again and restart ACS may solve this problem Go to C WINDOWS system32 ieee_32m dll and renamed it to ieee_32_old dll Install ACS 8 ACS always goes to demo mode after generated temporary license file You need to get the officially license file or USB key license the temporary license file is expired you cannot continue to use it Version 4 3 1 release Added KTEI version check before running BTI modules KTEI V8 1 SP2 or higher must be in installed Removed the Sorting radio box in the Summary Report panel Adjusted the total allowed plots to no greater than 36 in the wafer level plot and real time plot Added the CV_ACS lib file to avoid a link error when building a library using the create_DT tool Synchronized the usrlib mak file version with KTEI so that the file will not be removed when or if ACS is uninstalled Upgraded the User Accounts dialog box so that special characters cannot be entered Changed the OCR Reading code for a GPIB according to the S400 code which address the reading string issue Added check point in the process of launching KXCI For example if the UTMServer has not started ACS will wait until it starts successfully Model 4200 ITM updated so the call DE command will turn off the output There is a double delay time if you abort between the meas
36. s Measure Loop e Improved throughput with Model 707B chassis integration e Standard Kelvin configurations for both low current and high voltage e S530 Systems only System specifications to the PCA Probe Card Adapter including CV e S5xx Systems only Industrial PC with clean XP install no consumer starter software e 400 conversion tool e Command line execution of common ACS project and automation functions e Support for both DDC and ICL modes for Models 707B and 708B e Prober chuck connection when using a switch matrix e Perform diagnostic testing for the S530 System only e Ultra fast BTI reliability testing that uses AC and DC reliability stress and measure techniques e Statistics capability e Debug Python modules e Supports both symbol and 3 dimensional bitmaps e Supports Python Test Script Processor TSP and C programming languages e Available operator and engineer operation modes e Performs common transistor parameter testing for example Vds ld Vgs ld Vg lg e Performs life testing TDDB NBTI HCI using various projects e A script editor tool allows you to view and edit test code and export it into TSP and Python language libraries e Supports standard XRC and customized graphical user interfaces GUIs for PTMs and STMs and can bind events in customized XRC styles e XRC GUI Builder tool allows you to edit and view GUI layout for XRC format e System information can be accessed and s
37. t be absent or renamed If the C S4200 director is renamed rename it back to C S4200 NOTE this only applies you are not removing KTEI when you are install ACS on a Model S4200 SCS If the KTEI version is removed or reinstalled you need to reinstall ACS NOTE ACS and KTEI version share some dils You mustinstall KTEI and then install ACS Launch ACS 3 The problem may be caused by improper user environment variables ACS user environment value path maybe changed by other installation of other software packages Run Initialize New User tool from Start gt Program gt ACS X X Recommended Reboot you computer after new user initialization is complete Launch ACS Also you can manually check the user environment and modify value path Advance PA 1008 Rev G Dec 2011 15 Automated Characterization Suite ACS Release Notes Go to C ACS KATS ACS_Env ixt and open it Go to My Computer gt Properties gt Advance page click user environment button to open environment dialog compare the user environment value path with ACS_Env ixt file the path and pyLibrary etc value path should exist especially keep the ACS related value path keep in path header for example the path value as below Path C ACS KATS C S4200 sys bin C S4200 kiuser usrlib C S4200 sys openint dll Click OK button to exit user environment dialog Launch ACS 4 The problem may be caused by launching ACS from a different Windows user account
38. test Also the SMU Remote Sense option box in the Preference settings Misc tab will be disabled When all the matrices are set to Local Sense all of the Series 2600A and Series 2400 instruments in the system will be set to two wire 2 W mode when executing a test It is highly recommended that all the matrices in the system are in the same mode Support for the confidence check of the Model 707B matrix only in DDC mode After ACS has been launched user do not plug out and plug in USB GPIB cable from computer even the USB cable plug in again ACS still lost hardware control user need to restart ACS to solve it If installing the NI GPIB driver NI 488 2 v2 7 3 or above the NI VISA driver option is not selected as the default You must choose the NI VISA option when installing the NI GPIB driver If the NI VISA driver is not installed the instruments may not respond when running a PTM ACS only supports CEC488 GPIB drivers 8 2 or above If older drivers exist you will need to upgrade The symbol is a key character used in ACS It should not be used in ACS_PostData including ACSPostDataFloat ACSPostDataDouble ACSPostArraylInt and ACSPostArrayFloat etc Based on license mode of the USB key inserted you can access the different modes available in ACS for example Standard WLR and RF While importing the Model 4200 project files if the subsite does not have any libraries and modules described then importing the kpr Keithley Proje
39. to two wire 2 W mode when executing a test It is highly recommended that all the matrices in the system are in the same mode Support for the confidence check of the Model 707B matrix only in DDC mode If installing the NI GPIB driver NI 488 2 v2 7 3 or above the NI VISA driver option is not selected as the default You must choose the NI VISA option when installing the NI GPIB driver If the NI VISA driver is not installed the instruments may not respond when running a PTM ACS only supports CEC488 GPIB drivers 8 2 or above If older drivers exist you will need to upgrade The symbol is a key character used in ACS It should not be used in ACS_PostData including ACSPostDataFloat ACSPostDataDouble ACSPostArraylInt and ACSPostArrayFloat etc Based on license mode of the USB key inserted you can access the different modes available in ACS for example Standard WLR and RF While importing the Model 4200 project files if the subsite does not have any libraries and modules described then importing the kpr Keithley Project File will fail you will receive an error In addition the devices imported will appear incorrectly By default the beeper is disabled when executing a module If you want to disable enable the beeper when running a module refer to the following steps 1 Open the file ACS_setting ini in the KATS folder in the ACS file directory 2 Find enable that is under the item beeper beeper gt enable
40. ts Added a Copy 1st to all function which will copy the first setting of sub device1 to all the other sub devices Added the abilitiy for you to set up automatic updates to the real time plots Added the ability to delete the temporary log file and a new one created whenever you start ACS Added the option to sort 2600 based RTM test data output to generate a csv file according to the new order Support prober P300A Upgraded the USB license key driver in order to support Windows 7 operating system Upgraded the GeneralTestLib py and added step setting Added dual sweep and log sweep for the 4200 ITM Added a function that saves test data and test status to a xls file for manual testing on the data page Support ACS RTM UAP execution for manual testing Added a csvbak file that backs up your csv file in order to accomplish manual testing Added the ability to configure the plot to refresh automatically or manually for the 2600 based RTM tests Added an Export Data function in the real time plot window Added the ability to save a csv file while running an RTM test Added tests to the S530 Diagnostic and Confidence Test rows B to C D to E and F to G Changed settings so that the csv file is bound with the project Added 45 135 225 and 315 degree for the wafer notch Allow changing of wafer flat or notch location without coordinating transformation Ability to detect matrix errors as soon as they are encountered Added functi
41. unctional when the using the result of PCTSHIFT_TO Changed the ACSPostArratDouble output value to 12 digits Repaired the TDDB_CVS take data twice at last of stress problem Enabled the FS_NBTI RTM to insert global data in Inter Stress item Enabled the execendsetingFlag and defaultrangeFlag for single unit Repaired the Graph spread over screen by moving separator problem Repaired the HCI device2 s tab displays while only 1 sub device under test problem Added some limitations for RTM modules in Statistics Enabled the ability to easily remove and add the same external instrument with the same GPIB address Added a clear message when pre_test removes while global variable induced in meas for HCl Added an error check for device name and pad name in device edit tool Added an entrance for attribute T when multi devices test in HCI Added a GUI check for stress time setting in HCI Repaired the BTI script generation when not all subdevices selected for test Repaired the TDDB test is running without end when Points setup to 1 in linear mode problem Added a scrollbar enhancement for BTI stress settings Repaired the X Y value in offset settings Enabled the the re sort button to be grey while RTM test running 8 PA 1008 Rev G Dec 2011 Automated Characterization Suite ACS Release Notes Disabled the points if you select list of Time Array in TDDB GUI Repaired the ITM sweep setting changing when changing Measure item proble
42. urement trigger and the first point data return Updated PrbP8 dll for the getProberPostition c to support both three digit and four digit coordinate values returned from the prober Updated the ACS Reference Manual with new Statistics documentation Version 4 3 release NOTE If you have ACS v4 2 or earlier software installed on your PC and you are updating to ACS v4 3 you will need to perform the following operations first 1 Uninstall the previous version of ACS 2 Go to the C S4200 directory on your computer and rename it to C S4200_old NOTE this only applies if you are NOT installing ACS on a Model 4200 SCS Remove the C ACS KATS KATS_pref ini file Install ACS v4 3 PA 1008 Rev G Dec 2011 19 Automated Characterization Suite ACS Release Notes Enhancements Disabled points setting in ITM linear sweep X configuration you can only edit the step value the points value will be calculated automatically according to the step value For the log sweep X configuration you can edit the points value the step value cannot be used Supported copy partial data and export all data when right clicking at data page Adjusted the access in operator mode Added VALIDATE_OCR UAP to correct wafer id before it is written to the kdf file Added the prb_err_hdlr UAP If this UAP is added the test will not stop if a prober error occurs You will have to write a recovery prober error code at this point Added the FUNC_GET_PR