        ACTI-VOC Low-Flow Pump User Manual
         Contents
1.           Figure 6  Back pressure adapter with O ring extraction tool     e Take the replacement O ring and push it into back pressure adapter by hand     e Use Markes    O ring insertion tool  or similar blunt ended implement  to locate the replacement O ring into  the groove inside the back pressure adapter        Figure 7  Inserting a new O ring into the back pressure adapter     e Run the O ring insertion tool around the inner diameter of the O ring to ensure it is free from distortions              z  g  x  Y  O  Q  3    12       MARKES    international          5 Parts list  5 1 Accessories    Part number Description      C FLMTR Digital flowmeter    C LFPCAL 120 Primary standard low flow calibrator  120 V    C LFPCAL 230 Primary standard low flow calibrator  230 V       5 2 Spare parts    Part number Description         13    z  z     3  oJ      D  O  O      3       MARKES          6 Specifications   Dimensions   63 5 mm  W  x 34 9 mm  H  x 117 5 mm  L   2 50     W  x 1 38     H  x 4 63     L     Weight  Main unit  340 g  12 oz     Operating range  Constant flow mode   20 200 mL min    Operating range  Constant pressure mode     1 350 mL min  range dependent on tube impedance  Flows greater than 200 mL min are not achievable with    all TD tube types     Pressure range  Back pressure up to 25    H50     Flow control  5  of set point or  3 mL min  whichever is greater    Battery type  Rechargeable nickel metal hydride battery pack    Battery output  4 8 V  720 mAh    Ch
2.    MARKES       ACTI VOC    Low flow pump     7  FLOW ADJUSTMENT    MARKES    ACTI VOC  Low Flow Pump    22S  os We    TIME  MIN     A WARNING A    Possible static hazard  Do not rub with dry cloth   Substitution of components    Ex lb IIC T4  e SP AEx Ib IIC T4  2590415  cus  EEx ib IIC T4    This product is intrinsically Safe for use in Zone 1  amp  2 hazardous classified areas   Max Charging Voltage Um  21 Vrms   Max Charging Current  250 mA    Class    Groups A  B   Class Ill  T3C  Ex Ib IIC T4  AEx Ib IIC T4    C   amp  D  Class Il  Groups E  F   amp  G     Manufactured in the U S A  for Markes International Ltd    44  0  1443 230 935   www markes com       Operator Manual    Version 1 0  QUI 1086  March 2013    Markes International Ltd  T   44  0 1443 230935 F   44  0 1443 231531 E  enquiries markes com              z  g  x  Y  O  Q  3          MARKES       international    Contents  1 AP           A  3  1 1 DN ON Setar can pects anv nooo    3  1 2 DA    A  O A 3  1 3     A o o OO ge sassecetoass 3  1 4 PP e e e e Cie Pe A 4  1 5 Technical support contact details usd ad 4  A AP    P                 aaraa 5  SS PUNT OS ACN ri aiii ia isa ironico Eaa 7  3 1 SENE a Constant NOW PP    o    E a T  3 2 Using constantpressure MOC A       P ga oa aa ee acta a eaa Sa 9  3 3 Taki  g   a personal Sample y sextesasiiacisn cadecetseatcncadasnttadvananesdocatieantovavosdsertteadawcsnsadecedianoenuseadasutteatiavdecadaiuiaens 10  A VNR RING Ces cere iria 11  4 1 Battery MAINTENANCE se
3.  months to avoid complete discharge     The battery pack has an estimated life of 300 500 charge discharge cycles  depending on use  The  table below shows the estimated battery life based on usage level     Pump usage Estimated battery life          High  40 60 hours per week  1 1   years    Medium  20 39 hours per week  114 21 years       Blow all dust and debris from around the filter housing  Grasp the knurled edge of the filter housing   assembly and rotate counterclockwise  Check the new filter housing assembly to make sure that the  sealing O ring is present on the internal boss  Install the new filter housing assembly onto the pump   rotating the knurled edge clockwise  Do not overtighten     z  z     3  oJ      D  O  O      3    11       MARKES          4 3 Back pressure adapter O ring    The back pressure adapter connects the TD tube to the pump using an O ring seal  It is recommended that this  O ring is replaced every twelve months  or whenever it is noticeably damaged     The ACTI VOC is supplied with two spare O rings  Spares are also available for order as a pack of 10   Markes  International part number U COV45      The O rings can be replaced easily using Markes    O ring extraction and insertion tools  or other similar    implements  as described below     e Use Markes  O ring extraction tool  or similar pointed implement  to hook out the O ring  taking care not  to scratch the groove in which the O ring is seated  nor to damage the white PTFE insert behind 
4.  to  set the flow      Connect the TD tube to a suitable flow measuring device  e g  digital flowmeter or primary standard wet  bubble cell     Turn on the pump using a pointed instrument such as a ballpoint pen   Adjust the flow through the tube using the in line flow controller     Once the desired flow rate has been reached  the pump is ready for sampling     Note  In this mode the flow adjustment screw on the pump does NOT set alter the flow rate and should not be  used  The flow needs to be adjusted with a third party in line flow controller  contact your local Markes  International dealer for more information               3  y     Y  O      3       MARKES          3 3 Taking a personal sample       Figure 5  Taking a personal sample     e Remove both storage caps from the pre conditioned TD tube using the CapLok tool     e Place the pump  tubing  appropriate adapter and sample tube on the worker as shown  O   making sure  that the sampling flow direction arrow on the TD tube is pointing in the correct direction  towards the  pump   The tube can be held in position with a penclip    e Use a pointed instrument such as a ballpoint pen to turn on the pump  8     e When sampling is completed  use a pointed instrument such as a ballpoint pen to turn off the pump  6    Record the sample data    e Re cap the sample tube  finger tight plus a quarter turn  with the CapLok tool    2 When the pump is turned off after a sample run  the total run time in minutes  to the nearest  0 0
5. 1 minute  is displayed  To calculate the total air volume sampled  use the following formula    Sample flow rate  mL min  x Sample time  min     Total air volume  L    4000             z  g  x  Y  O  Q  3    10             4 Maintenance    4 1 Battery maintenance    ACTI VOC uses rechargeable nickel metal hydride  NiMH  batteries that must be fully charged and properly  maintained to obtain the maximum run time  The battery is rated at 4 8 V  720 mA h      4 2 Filter maintenance    Under normal operating conditions  the pump filter should be changed after approximately six months or  250 hours of operation  or when needed  Failure to change the filter as it becomes dirty will decrease the  pump   s back pressure capability and performance range     MARKES    Do not charge the battery pack in an explosive atmosphere     Make certain the charger plug is fully inserted into the jack on the battery pack  see Figure 2  label 11   for the location of the Charging jack      The charger can be damaged by line transients and overvoltage  Although this is not a common problem   long term reliability can be improved by use of a surge overvoltage protector     Both charger and battery pack become warm during charging   Do not short battery terminals  as this will blow the internal fuse     All NIMH batteries lose charge when not in use  If the battery pack has not been charged for 3 4 days   recharge it before use  NiMH batteries stored for extended periods should be recharged every  1 2
6. J       AS  FA    Seca o       Figure 4  Setting a constant flow rate     e Turn onthe pump using a pointed instrument such as a ballpoint pen        e Make sure the flow measuring device is on and working   e  Useaflat bladed screwdriver to make flow adjustments on the pump itself  O      e When the desired flow rate has been reached  turn off the pump and flow measuring device  The pump  is now ready for sampling     s         3  g  x  Y  O  Q  3          MARKES    international       3 2 Using constant pressure mode    Constant flow mode is the recommended operating mode for TD applications     Constant pressure mode allows pumping in the flow range 1 350 mL min  but the range is dependent on tube  impedance and the flow needs to be adjusted with a third party in line flow controller  not supplied with the  pump   contact your local Markes International dealer for more information   Flows greater than 200 mL min  will not be achievable with all TD tube types     To switch to constant pressure mode     Insert the Hex key into the hex head screw on the pump    Turn the key anticlockwise to change the mode    Continue turning the key until the mode indicator shows white for constant pressure   Turn the key clockwise to lock your selection    Attach tubing to the pump inlet     Connect the TD tube to the tubing via the in line flow controller   When setting a sampling flow with the  pump in constant pressure mode  the actual tube which is to be used for sampling should be used
7. arging  Internal  external with adapter     Operating temperature   20  C to 45  C   4  F to 113   F     Storage temperature   40  C to 45  C   40  F to 113   F     Charging temperature  0  C to 45  C  32  F to 113  F     Additional features    e Flow fault indication LED   e Battery check LED   e    Be It clip   e Dual filtration system   e External flow adjust   e Elapsed timer clock module   LCD display  e Automatic instant fault shutdown function  e RFI shielding    14             3  y     Y  O      3       
8. ctions and warnings in  this manual  or otherwise provided by the seller or from not adhering to all federal  state  and local  environmental and occupational health and safety laws and regulations     The seller shall not be liable for direct  indirect  consequential  incidental or other damages resulting from the  sale and use of any goods and sellers    liability hereunder shall be limited to repair or replacement of any goods  found defective  This warranty is in lieu of all other warranties  expressed or implied  including but not limited to  the implied warranties of merchantability and fitness for use or for a particular purpose which are expressly  disclaimed     1 3 Warnings    READ AND UNDERSTAND ALL WARNINGS AND INSTRUCTIONS BEFORE USE    e Failure to read  understand  and comply with ALL accompanying literature  product labels  and warnings  could result in property damage  severe personal injury  or death     e Read and understand ALL applicable environmental health and safety laws and regulations  Ensure  complete compliance with ALL applicable laws and regulations before and during use of this product     e DONOT remove  cover  or alter any label or tag on this product  its accessories  or related products   e UNDER NO CIRCUMSTANCES should this product be used except by qualified  trained  technically  competent personnel     e DO NOT operate this product should it malfunction  require repair  or have a cracked or broken case   DO NOT repair or modify this prod
9. in Zone 1  amp  2 hazardous classified areas   Max Charging Voltage Um  21 Vrms   Max Charging Current  250 mA  Class I  Groups A  B  C   amp  D  Class II  Groups E  F  4 G    Class Ill  T3C  Ex Ib IIC T4  AEx Ib IIC T4   in the U S A  for Markes International Ltd    44  0  1443 230 935   www markes com                  Figure 1  Front view of ACTI VOC     OOOO  Bo  x Bese Re    Figure 2  Back view of ACTI VOC           z      3  D  A   D  O  A  Q  3          MARKES       international    3    Pump operation    3 1 Setting a constant flow rate    Calibration  flow rate verification  must be performed before sampling and when setting the flow rate  See    Figures 3 and 4     Ensure the ACTI VOC is fully charged  Insert the Hex key  0    into the hex head screw on the pump     Turn the key anticlockwise  6  to change the mode     Continue turning the key until the mode indicator shows black for constant flow          Turn the key clockwise     to lock your selection     yo         RR         Figure 3  Setting the pump to constant flow mode     Attach tubing to the pump inlet     Connect a TD tube to the tubing via the appropriate adapter  Use the back pressure adapter when  setting flows up to 100 mL min  use the plastic tube adapter assembly when setting flows in excess of    100 mL min     Connect the TD tube to a suitable flow measuring device  e g  digital flowmeter or primary standard wet    bubble cell                 z  g  x  Y  O  Q  3          MARKES                 J 
10. ing air Sampling bags     Case screw  These screws must remain tight and should be checked prior to beginning sampling     Charging jack  The Charging jack receptacle is used to connect a charger for recharging the internal battery pack     Belt clip  Rechargeable battery pack    Mode indicator  The Mode indicator visually confirms the sampling mode selected  black for constant flow  and white for  constant pressure      Mode selector  The Mode selector is used to change the sampling mode  The selector is used for unlocking  indexing  and  re locking the mode selector valve while changing from constant flow mode to constant pressure mode     Hex key    Back pressure adapter   The metal Back pressure adapter gives the required minimum back pressure the pump needs for low flow  TD use  Use this in conjunction with the Ys    tubing from  18  with standard 1   4    and 6 mm o d  TD tubes for  flows up to 100 mL min     Tubing assembly  Use the plastic tube adapter  shown as part of the tubing assembly  in place of the Back pressure adapter  when sampling onto SafeLok tubes or at flows greater than 100 mL min              3  y     Y  O      3          MARKES    o     D09 0 0 0 0  gt   m 09209090 RARA D       MARKES    ACTI VOC  Low Flow Pump                    A WARNING A   Possible static hazard  Do not rub with dry cloth    Substitution of components may impair instrinsic safety    O LE eee  Do not charge in hazardous    CE     6 2     This product is intrinsically Safe for use 
11. ort markes com   Tel    44  0 1443 230935   Fax   44  0 1443 231531     9J     UY  E  O   4 3             2     1      2      3      4      5    6      7      8      9      10      11      12    13    14      15      16    17      18     MARKES    Components    Air inlet  The air inlet is located on the filter housing and provides a built in means of attaching tubing for suction  sampling     Air inlet pump filter  A 10 um nylon air inlet pump filter protects the pump assembly from dirt     Flow adjustment  Requires flat bladed screwdriver     Battery check  This green LED  B  indicates that sufficient battery power is available to run the pump for 8 hours under  normal load conditions     ON OFF switch    Fault indicator   This red LED  F  indicates a flow fault due to excessive back pressure or insufficient battery voltage to  maintain flow  If flow changes exceed 5   fault icon appears  If fault exceeds 30 seconds  pump shuts  down and display will show sample time     Clock display   The Clock display shows the continuous run time  in minutes  to two decimal places   and will lock in the  sample time upon fault indication  The time will reset to zero when the power switch is turned OFF and  then back ON again     Outlet port  The Outlet port provides a receptacle for the bag sampling accessory  The screw cap prevents dirt from  entering the Outlet port when not in use     Bag sampling accessory  When installed into the Outlet port  this accessory provides a means for fill
12. risinin EEK aE aE oy AN EEE EAEE EAEE ARER 1i  4 2 PUG MGIMTON ANCE sorna oir indica 11  4 3 Back pressure adapter ONG siracsisnavanencaducagasdcameesaennmesuanatanesayancausseaneacs asusindns oanainaeeuaeinaesasnraneneneduanameads 12  S Parno US AP A  ccanaueeasnuetcassucstsanuuseneectenseacseaueueasussacausieanecakendeiuassasibacansususentuacdeasnuueussdercanseatuniwusseusenssaneds 13  DL PCOS SO SS rt ais 13  5 2 o    PP    13  6     SHSCCHICAUONS simi aa NN 14             3  y     Y  O      3       MARKES          1 Introduction    1 1 Notices    This manual was prepared exclusively for the owner of the Markes International ACTI VOC Low flow pump  The  material within this manual is proprietary information and is to be used only to understand  operate  and  maintain the instrument  By receiving this document  the recipient agrees that neither this document nor the  information disclosed within nor any part thereof shall be reproduced or transferred  physically  electronically or  in any other form  or used or disclosed to others for manufacturing or for any other purpose except as  specifically authorised in writing by the manufacturer     1 2 Disclaimer    The seller assumes no responsibility whatsoever  to any party whosoever  for any property damage  personal  injury  or death received by or resulting from  in whole  or in part  the improper use  installation  or storage of this  product by the user  person  firm  entity  corporation or party not adhering to the instru
13. s   or establishing from material data sheets that it is resistant to specific chemicals     e DO NOT operate the product with a dirty or blocked inlet filter or kinked tubing  Pump failure or faulting  may result     e Both charger and battery become warm during charging     1 4 Certifications    Explosion protection     Il   Equipment group A WARNING A Saeed equipment in compliance with   2   Equipment category   Possible static hazard  Do not rub with dry cloth  AEx   FM 3610  G   Hazardous gases  vapors or mists epa  of decis bic ee aes b  inttincie sarety proveetion method   Do not charge in hazardous locations  IIC   Gas group   T4   135  C  maximum external surface temp   Ex Ib IIC T4  CE marking and number of notified       0518 2G SB AEX ib NO T4  body responsible for production SIRA 03ATEX2137    EEx ib IIC T4  This product is Intrinsically S      ade    Certification number       le St CSA marking  44  0  1443 230 935   www markes com  Explosion protection equipment in compliance with  EC type examination  EEx   CENELEC EN 50014 series certification number  ib   Intrinsic safety protection method  IIC   Gas group    T4   135  C  maximum external surface temp     1 5 Technical support contact details    In the first instance please contact your supplier  If they are unable to resolve your query  please contact Markes  International  details below      Address  Gwaun Elai Medi Science Campus  Llantrisant  RCT  CF72 8XL  UK   Website  www markes com   E Mail  techsupp
14. uct  except as specified in this manual  No user serviceable parts are  located within the case  Contact Markes International for service related queries    e Use only specified Markes parts when performing maintenance procedures described in this manual   Intrinsic safety certifications become void by substitution of components  unauthorised repair or  alteration    e This product is intended for both indoor and outdoor use when protected from splashed or wind blown  liquids  The unit is not waterproof  so NEVER submerge the unit in water  Pump failure or faulting may  result     e This product presents a possible static hazard  Do not rub the product with a dry cloth   e DO NOT charge the battery in an explosive atmosphere     e This product uses rechargeable nickel metal hydride batteries  which should always be fully charged  before use  Use only the battery pack and chargers specified in this manual  DO NOT insert any foreign  objects into the contact slot  Shorting contacts will blow the protective fuse     e   If the equipment is likely to come into contact with aggressive substances  then it is the responsibility of  the user to take suitable precautions that prevent it from being adversely affected  Examples of             3  y     Y  O      3          MARKES       aggressive substances are acidic liquids or gases that may attack metals  or solvents that may affect  polymeric materials  Examples of suitable precautions are regular checks as part of routine inspection
    