What`s new in WindO/I-NV2 Version 4.64

image

Contents

1. have been fixed After deleting a picture from the Picture Manager that was registered to a project and then importing a new picture file caused the screen to display an incorrect picture a When registering multiple pictures in an HG3G project that was created in Ver 4 2 opening or uploading the project in Ver 4 30 displays an error message that states Insufficient memory What s new in WindO I NV2 Version 4 30 lt Runtime System Software gt Improvements The following Improvements have been added HG3G Remote Monitor and Control function Using a web browser on your PC PDA or smart phone you can remotely monitor amp control the HG3G Series amp PLC for easy maintenance test or troubleshoot Be able to mount in Portrait Vertical mode The line chart displays time on the x axis at the cursor position when in manual mode Data logs support 32 bit data BIN 32 BIN 32 BCD 8 or float 32 Pictures can be set as a background image of the following parts Numerical Input Numerical Display Character Input Message Display Message Switching Display Calendar Meter PictBridge protocol for USB printers is now supported The USB printer can print screen images and alarm log data Brightness can be adjusted in 48 levels Bugs Fixed The following problems have been fixed HG3G The screen title was missing when a Picture Display was placed at the top of a popup screen Picture Display reference devic
2. the Modbus TCP Client no recovery when a communication error occurs This is applicable to HG4G 3G HG2G 5F 5S S a When the 1 N Communication is selected a value may be read for the Address differs from the one specified according to the combination of the Station Number and the Address This is applicable to the following Host I F drivers Ethernet IP Logix DF1 Full Duplex DirectLogic Ethernet KV Ethernet MELSEC FX3U Ethernet lt Application Software gt Improvements The following Improvements have been added New features or improvements are added from the Runtime System Software upgrade a When creating a new project the description for the HG Special Registers LSD and the HG Special Relays LSM is now registered in the Comment Bugs Fixed The following problems have been fixed m When changing the O I Type from HG4G 3G to HG2G 5F the size of the Popup Screen may not be change correctly m When opening a project saved with WindO I NV2 Ver 2 50 or earlier in Ver 4 00 or later and changing the O I type from HG4F 3F 2F to HG4G 3G HG2G 5F the settings in the Communication I nterface tab may not be converted correctly The data under the Data List on Recipe Settings might change values to 0 if the following actions are taken Change O I type Upload a project Change the Access to for the Recipe Settings from the Memory Card to Internal Memory The tag name may be judged as an error in the S
3. F HG4F support VIGOR VB VH Series PLC e The stability and reliability of the communication are improved in SIEMENS S7 MPI driver 2 Bugs Fixed lt Application Software gt 1 Improvements e Replace for Device Address is supported when Connection Type is 1 N Communication e Preference settings of Tag Editor are moved from WindO I NV2 Options dialog box to Context menu of Tag Editor lt Manual gt 1 Instruction Manual Add notice about the write number of times in Flash Memory by using HG Special Relay LSM10 WindO I NV2 Version 4 10 lt Runtime System Software gt 1 Improvements HG2G DC12V model is now supported HG2G Pass through function via Ethernet is now supported The touch panel determination handling has been improved to avoid the unexpected behavior which caused by pressing two p oints at the same time When pressing two points at the same time the second one will not be accepted 2 Bugs Fixed O Link Communication do not work when SERIAL I F 1 is set as O I Link Slave and SIEMENS S7 MPI or S7 200 PPI is selected as Host I F Driver in HG2G series lt Host I F Driver gt 1 Improvements The communication driver has been added for Toshiba EX100 to HG1F HG2F HG2G HG2S HG3F and HG4F series 2 Bugs Fixed The Event Output might not work if DM Link 1 1 or DM Link 1 N with HG2G Series is selected lt Application software gt 1 Improvements Able to open the Tag Editor from
4. Ifa project is downloaded with text registered in Text Manager as the Registration Text for a Multi State Lamp it may not be displayed on the MICRO I This is applicable to HG4G 3G HG2G 5F f scripts are configured that use the ASCIIZ2DEC STRSTR or STRLEN functions in projects saved with versions before 4 44 NG may be displayed in Script Manager when those projects are opened with version 4 50 and later but before Ver 4 60 The Disk is full error might be displayed if projects saved with versions before 4 44 were later opened in version 4 50 to 4 60 a Ifa project created as 1 N Communication under Connection in the host I F driver settings is changed to 1 1 Communication the values of devices configured with a station number other than 0 can no longer be read or written a Ifthe O I type is changed the Alarm Log Display data becomes invalid and when this project is downloaded the MICRO I resets This is applicable to HG4G 3G HG2G 5F m Ifthe O I type is changed to HG4G 3G HG2G 5F with project data uploaded from HG1F 2F 2S 3F 4F the picture data may disappear What s new in WindO I NV2 Version 4 52 4 60 What s new in WindO I NV2 Version 4 60 lt Runtime System Software gt Improvements The following Improvements have been added The IP address for hosts configured in Project Settings and Host I F Network can now be modified on the System Menu This is applicable to HG4G 3G HG2G 5F 5S S For details refer to Chapte
5. Input This is only applicable to HG2G S 5S 5F HG3G 4G The User Communication supports full duplex when using HG2G S Improvements have been made to print from the tray corresponding to the normal paper type in the printer side settings when using the print function of the HG3G Bugs Fixed The following problems have been fixed When switching an operating mode with the HG3G E g switch from the System Mode to the Run Mode the SD memory card may not be recognized causing operation to stop When using the Remote Control function with the HG3G the screen will continue to be displayed on the web browser even if screen display has been turned off At power on of the HG3G the expansion module may not be recognized In the HG2G 3G two overlapped buttons can not be active even if Enable Two point Push in Project Settings is enabled This problem only happens if one of the buttons is located in a Base Screen and another button is located in the Popup Screen In addition Superimpose is set as Screen Effects in the Popup Screen If the DM Link communication is used with the HG3G the HG3G may stop running when it sends a reply for a request command and an Event Transmission at the same instant lt Host I F Driver gt Additional supported Drivers HG3G PLC 5 Half Duplex SLC 500 Half Duplex 7 300 3964 R RK512 Power Mate MODEL D Series 16i MP920 RTU MICRO3 MICRO3C Ethernet IP Logix Native Tag Bugs Fixed The f
6. Video display For instance if the original display size of the movie file is 100x100 and the size of the Video display is 400x400 the original movie file display will get adjusted automatically to 200x200 HG3G 4G video interface equipped models The video display can be setup and connected at anytime There is no restriction as to when it can be connected Added the Slow and the Frame Fwd to the Key Button for the HG3G 4G video interface equipped models When connect a device to Audio IN Audio Out interface of the HG3G 4G use stereo mini plug If the device only supports monaural input output use a monaural to stereo converter Bugs Fixed The following problems have been fixed HG3G 4G models not equipped with the video interface Sounds with a specific sampling frequency does not play normally When monitoring HG2G 5F HG3G 4G with the Remote Control function the O I Type on the Target Information page always shows HG3G The picture may remain displayed when a movie finishes playing This is applicable to HG3G 4G with video interface only The File Screen for movie data may not update This is applicable to HG3G 4G with video interface only If the number of alarms that occurred on HG S 5S 5F HG3G 4G exceeds the Number of Stored Data for Alarm Log HG S 5S 5F HG3G 4G may reset or stop displaying data on the Alarm List Display and Alarm Log Display lt Host I F Driver gt Expanded Drivers Extended th
7. What s new in WindO I NV2 Version 4 64 lt Application Software gt Bugs Fixed The following problems have been fixed This is applicable to a communication driver Allen Bradley Ethernet IP Logix Native Tag If a project is downloaded after editing a host communicaiton error may occur on the Touchscreen What s new in WindO I NV2 Version 4 63 lt Runtime System Software gt Bugs Fixed The following problems have been fixed a f Windows font is used as unit in Numerical Display and Numerical Input a part of these frange may be filled with the plate color This is applicable to HG2G 5S S lt Application Software gt Bugs Fixed The following problems have been fixed Project Settings dialog box can get an error and cannot be closed if projects saved with version before 4 44 are opened with Ver 4 62 This is applicable to HG4G 3G and HG2G 5F The Property dialog box of the part objects can get an error and cannot be closed if the Trigger Condition is enabled and the Trigger Type is While satisfying the condition or Satisfy the condition This is applicable to HG4F 3F 2F 2S 1F What s new in WindO I NV2 Version 4 62 lt Runtime System Software gt Improvements The following Improvements have been added Improved the project upload process WindO I NV2 only uploaded the related files from the Access folder in the SD card when uploading a project file This is applicable to HG4G 3G HG2G 5F Retained the te
8. WindO I NV2 when launched from WindCFG Able to change the disp lay order an d hide the T ag Name co lumn to Options dialo g box of WindO I NV2 The customize feature of Quick Access Toolbar has been improved You can open the T ag Editor from Device Add ress Settings di alog box an d che ck the Device Address usage The Replace Device Address feature is supported and it is found at the Editing group on the Home tab The icon displayed on the Editing Window tab has been modified to conform t o the icon fo r Base Screen and Popup Screen displayed on Ribbon Control and Project Window The operation of a zoom slider on the Status Bar has been improved The short cut menu of Tag Editor is added on the Project Window The following icons are modified on th e Project Window Text Manager Picture Man ager and Script Manager Editing the F ocus Ord er for Nume rical Input and Chara cter Input without changing the Scree n Properties is now available 2 Bugs Fixed The following problems have been fixed After changing the Host I F Driver the Error Check has failed to check for device addresses used in the screen data The CSV file can not be importe d with Tex Manager if it includes the string with over 500 bytes in size After opening the project and Auto Hide function is enabled the Project Window Screen List Object List Part List and Toolbox are displayed Even though the project is saved the information on the Screen List win
9. a different name in the same folder a When Data Type is set as float32 for a Numerical Inputnumerical display or numerical input partNumerical Display the Minimum and Maximum values for the Data Over range would revert to 0 even if they were set to values other than 0 What s new in WindO I NV2 Version 4 12 lt Runtime System Software gt Bugs Fixed The following problems have been fixed m Watch Dog function does not work in HG2G HG1F HG2F HG2S HG3F HG4FE series after the MICRO I recovers from Host Communication Error lt Host I F Driver gt m The Ethernet Communication Driver for Omron PLCs has been added in HG2G HG3F HG4F series lt Application software gt The following problems have been fixed m The Forbid Web Server function checkbox on Project Settings dialog box gt Communication Interface tab is always disabled not selectable when O I Type is HG3F or HG4F series lt Manual gt Communication Manual The Expansion Communication Module RS485 part number FC5A SIF4 has been added in the Communication Manual Pass Through Tool Manual Capter 4 Operations Note has been updated What s new in WindO I NV2 Version 4 11 lt Runtime System Software gt 1 Improvement The maximum number of screen capture can be set by entering a value in the HG Special Register LSD65 This is only applicable to HG3F HG4F Series 2 Bugs Fixed lt Host I F Driver gt 1 Improvement e HG1 F HG2F HG2G HG2S HG3
10. an not download upload a project In addition Remote control function may not be available m In the HG2G 5F and HG3G 4G MICRO I may not recognize SD Memory Card lt Host I F Driver gt Bugs Fixed The following problem has been fixed PLC device value may not be updated if using Koyo DirectLogic DL205 405 driver a If Keyence KV 3000 5000 driver is selected in the project the device value of Link Relay B Work Relay VB and Link Resistor W may not be referenced to the PLC device value In addition If you write a value to those devices it may not be written to the PLC lt Application software gt Bugs Fixed The following problems have been fixed a Inthe Individual Settings dialog box of the Recipe Settings on the Data tab 0 is always set to the Data column in the Data List if the Memory Card is selected from the Access to What s new in WindO I NV2 Version 4 41 lt Host I F Driver gt Additional supported Drivers a MITSUBISHI FX3U Ethernet YOKOGAWA FA M3 Ethernet Expanded Drivers a KEYENCE KV5000 driver Added more range or device addresses Bugs Fixed The following problems have been fixed Communication error occurs on the HG2G 5F HG3G 4G if using the Allen Bradley Ethernet IP driver Communication may slow and communication errors may be displayed if using the the KEYENCE KV Ethernet driver with the HG2G S 5S lt Application software gt Bugs Fixed The following problems have been fixed a Ifth
11. art FC4A FC5A Web Server Unit FC3A FC4A FC5A Supported AutomationOrganizer United SM to M and united SD to D Changed the name of TN to TC and CN to CC Changed the name of Device number to Network Number lt Manual gt 1 Instruction Manual Modified the Manual No of Instruction manual to HG9Y B1118 Fixed Problem WindOI NV2 Version 4 00 lt Runtime System Software gt 1 HG2G Host I F Driver S7 MPI Fixed that in the software Ver 3 41 or Ver 3 42 Host Communication Error would be shown if using S7 MPI driver 2 HG2G Screen Fixed the MICRO I reset problem The MICRO I reset if the following conditions were met 1 A non existing base screen is set as an overlay screen for a base screen 2 Selects the Display Order of Overlapping Screen to a non existing overlay screen number 3 The program is downloaded to the MI CRO I 4 When the screen is switched to a base screen that is set as a non existing overlay screen in Monitor Mode the MICRO I is reset lt Host I F Driver gt 1 HG2G OMRON SYSMAC C Fixed the following bugs Bits are not kept in a byte when the bit write is executed The value of one device read from PLC first is not updated 2 HG1F 2F 2S 3F 4F OpenNet FC3A MicroSmart FC4A FC5A Web Server Unit FC3A FC4A FC5A Host Communication Error would be shown if the project data contained the following condition when using HG1F 2F 2S 3F 4F Reading more than 20 consecutive addresses and the dev
12. b Server tab on the Project Settings dialog box does not work properly This is applicable to HG4G 3G HG2G 5F In the System Detail Information page on the Web browser the IP Netmask Gateway and MAC Addresses are displayed incorrectly This is applicable to HG4G 3G HG2G 5F The limitation of the read device addresses per Base Screen is 256 If the total read device addresses on a Base Screen is 256 MICRO I may display the Device Range Error This is applicable to HG2G S 5S f you repeatedly press the touchscreen for 3 seconds you can go to the system mode without the password confirmation even though the touchscreen s project is password protected This is applicable to HG4G 3G HG2G 5F What s new in WindO I NV2 Version 4 50 4 51 What s new in WindO I NV2 Version 4 51 lt Runtime System Software gt Bugs Fixed The following problems have been fixed a HG4F EX4R HG3F 2F 2S 1F may reset if some data is written to Device Address with Downloader while occuring Host Communication error a When the following conditions are satisfied HG2G 5F and HG4G 3G can t copy Data Log to Device Address with Data Log function Data Size is 32 bit The number of the logged Data is greater than the setting of Number of Stored Data for Data Log per Device The setting of End No for Target Data is greater than 1 lt Application Software gt Bugs Fixed The following problems have been fixed Script Manager shows an
13. cript Editor When a project is opened the size of the NV2 Metafile NMF may change A confirmation to save may be displayed when closing the project or when downloading even when the settings for the project and the screens are unchanged If the project is downloaded via Ethernet the system software download may fail If a project for HG4G 3G HG2G 5F created with WindO I NV2 Ver 4 44 is used a button may function though the another button is pressed on the screen of MICRO I When uploading the files from the memory card it may fail If Download Project is performed with the option Modified Data Only and that operation is failed by canceling the operation or occurring a communication error WindO I NV2 returns an error when performing the same operation again What s new in WindO I NV2 Version 4 44 lt Runtime System Software gt Improvements The following Improvements have been added Added the recording function to the HG3G 4G video interface equipped models Increased the number of blocks for the alarm log setting to a maximum of 128 This is applicable to HG2G S 5S 5F HG3G 4G Increased the amount of alarm log data storage with the data storage area setting for the following models HG2G S 5S 5 520 points HG2G 5F HG3G 4G 11 660 points HG3G 4G video interface equipped models Added a function to adjust the size of a the movie file display to be 2x the display size so it will display correctly on the
14. dow is not updated After st arting drawin g by doubl e clicking the drawing object on the toolbox you can not keep drawing if you delete object with Delete key Multiple users can easily edit one project at the same time The items you select for the Workspace under Setup gt Object List tab are showing differently on the Object List window The project file name is kept in the Recent Project list even if you never saved it If you change the font setting for multiple buttons by using the common properties dialog box it will not apply properly The display text on the importe d screens are not correct even if you have chang ed the T ext ID numbers when you import the screens which use the same ID numbers in the editing project lt Pass through Tool gt 1 Improvements Pass Through via Ethern et between the MICRO I and the PLC Programmi ng Software is now available lt Manual gt Instruction Manual Chapter 26 Pass Through Function Updated the contents of HG2 G series supporting Ethernet Pass Through Improved Fixed Problem WindO I NV2 Version 4 01 lt Runtime System Software gt 1 Project Data size Incresed the downloadable project data size for HG1F and HG2F to the same size as Ver 2 3 of runtime WindO I NV2 Ver 3 3 lt Application software gt 1 Change O I Type Fixed that WindO I NV2 showed the error message and froze when you tried to change the O I type after exporting the project from WindCFG 2 O
15. e MICRO I type in a project that uses a period in the project name anywhere other than the extension is changed the location where the MICRO I internal devices had been configured becomes blank For instance if you make a project named aaaa bb for HG3G the project file will be aaaa bb n3g And you set a LM 100 HG Internal Device to the Bit Button in this project After changing the O I type from HG3G to others you will see that the device setting of the Bit Button is deleted You may no longer be able to change the MICRO I type when opening a project created with an old version m Projects cannot be downloaded to the HG2S When multiple pictures are registered in Picture Manager if one of the pictures is removed and Picture Manager is reopened WindO I NV2 might crash What s new in WindO I NV2 Version 4 40 lt Runtime System Software gt Improvements The following Improvements have been added Supports 5 7 HG2G 5S 256 color TFT LCD Screen amp HG2G 5F 65K color 8 4 amp 10 4 HG3G w Multimedia and 12 1 HG4G w Multimedia HG3G 4G Series support multimedia Video Input Users are able to display video images on the touchscreen or play back a movie file stored from the SD memory card HG2G 5F HG3G 4G supports letter size paper when using the print function HG2G S 5S does not support the letter size paper Back Space BS key has been added as a key button on a Key Pad when pressing the Numerical
16. e displayed a If the Numerical or Character Input is protected by using the Security Function you can still set a value to it When you moved the focus to it by using the Focus is moved by ENT button setting this problem occurs Text within the text display area frame on parts in WindO I NV2 may not be displayed on the MICRO I This is applicable to HG4G 3G HG2G 5F The message in the Result window at times doesn t appear after copying the files from SD card to USB flash drive using the Key Button to transfer data m After copying the files by using the Key Button labeled Copy Files under Data Transfer on either Memory Card or USB flash Drive the folder icon is displayed without the folder name This is applicabl eto HG4G 3G HG2G 5F This is shown on the PC Data cannot be uploaded from a Memory Card inserted in the MICRO I set to O I Link Slave This is applicable to HG4G 3G HG2G 5F m The Web Server function cannot be used from Internet Explorer with certain PCs This is applicable to HG4G 3G HG2G 5F lt Host I F Driver gt Additional supported Drivers a FUJI MICREX SX Serial a FUJI MICREX SX Ethernet Emerson Floboss107 Bugs Fixed The following problems have been fixed a When the Allen Bradley PLC 5 or SLC500 is selected for the Expression of Device Address Format the Device Monitor cannot be used This is applicable to HG4G 3G HG2G 5F 5S S a When the 1 N Communication is selected for the Connection with
17. e information A command that rebuilds device address usage information has been added Right click the tag editor in the project window and then click Rebuild Bugs Fixed The following problems have been fixed The device usage information will become invalid in Tag Editor or Cross Reference a When an old version of the project has been opened the device address that has been set may disappear a When using the HG3G and setting it to the USB port in communication settings and if a project is downloaded while monitoring or while in simulation the monitor or simulation mode will not reopen after the download is complete lt Downloader gt Improvements The following Improvements have been added Supports 5 7 HG2G 5S 256 color TFT LCD Screen amp HG2G 5F 65K color 8 4 amp 10 4 HG3G w Multimedia and 12 1 HG4G w Multimedia A command line that downloads projects without clearing the HG Keep Register LKR and HG Keep Relay LK has been added A command line that downloads projects without downloading picture or sound data to the memory card has been added Bug Fixed The following problem has been fixed Projects cannot be downloaded to the HG2G S lt USB Autorun Definition File Creation Tool gt Added the USB Autorun Definition File Creation Tool which generates USB Autorun definition file that are required when using the USB Autorun function Go to Start menu click Automation Organizer WindO I NV2 and
18. e range of usable devices for Allen Bradley PLC 5 Half Duplex Applicable for HG2G S 5S 5F and HG3G 4G Bugs Fixed The following problems have been fixed If I gnore communication errors and continue operation is selected as one of the host I F drivers below the value for the host devices may not be set in parts and settings OpenNet FC3A MicroSmart FC4A FC5A DirectLogic DL205 405 Modbus RTU MODBUS TCP Client Web Server Unit FC3A FC4A FC5A Ethernet IP MELSEC Q QnA Ethernet Logix DF1 Full Duplex DirectLogic Ethernet SYSMAC CS1 CJ Ethernet Modbus ASCII KV Ethernet Ethernet IP Native Tag lt Application software gt Improvements The following Improvements have been added New features or improvements are added from the Runtime System Software upgrade Bugs Fixed The following problems have been fixed a After the project is downloaded to the MICRO I with the Zooming Conversion selected and Change O I Type executed the size of parts displayed on the MICRO I differs from the size displayed on the WindOl NV2 If you change the project file name for HG2G S 5S in Windows Explorer the project can not be downloaded to the touchscreen a Upload a project from HG2G S with project file created in WindOI NV2 ver 4 24 or older the device settings are completely erased if the project name is changed in the upgrade version What s new in WindO I NV2 Version 4 43 lt Runtime System Soft
19. ect USB barcode readers Ability to set the names of files stored in SD Memory Card when using the Alarm Log Data Log Operation Log and Recipe functions An automatic dimmer function The HG Special Internal Register LSD31 capable of saving screen numbers The HG2G Series now supports The HG Special Internal Register LSD31 capable of saving screen numbers lt Host I F Driver gt Improvements The Modbus ASCII Communication Driver has been added lt Application software gt Improvements The following Improvements have been added m Items concerning models functions and settings in conjunction with the runtime system software for HG3G series improvements Logical AND amp amp and Logical OR as logical operators for part trigger conditions The picture data for HG3G Tag Editor now supports Allen Bradley device addresses lt Manuals gt Bugs Fixed Communication Manual The following connection diagrams have been revised a Allen Bradley Connection Diagram 4 HG2G 3G Terminal a YASKAWA Connection Diagram 3 All models a DM Link Communication Connection Diagram 3 1 1 HG2G 3G Terminal HG2F 3F 4F What s new in WindO I NV2 Version 4 14 lt Application software gt Bugs Fixed The following problems have been fixed The program would sometimes crash when the user edited a new project or an existing project saved in the folder set as the default path and then attempted to save the project under
20. error when using the bit of word device E g LDROO00 0 The tag name for the bit of word device cannot be allocated to the property of parts and the respective settings What s new in WindO I NV2 Version 4 50 lt Runtime System Software gt Improvements The following Improvements have been added m Added an advance function to each part with the option to make a part i e button operable or non operable and visible or hidden depending on the device value or condition This is applicable to HG4G 3G HG2G 5F For details refer to the Trigger Condition Tab of each parts of the WindO I NV2 User s manual B1119 9 m Itis now possible to set the User Communications to the Ethernet Interface This is applicable to HG4G 3G HG2G 5F 5S S For details refer to Chapter 4 3 2 Communication Interface Tab on page 4 32 of the WindO I NV2 User s manual B1119 9 m Add the HG Special Relay LSM24 This bit is ON while writing to the memory card This is applicable to HG4G 3G HG2G 5F For details refer to Chapter 32 HG Special Relay LSM on page 32 3 of the WindO I NV2 User s manual B1119 9 Bugs Fixed The following problems have been fixed The display update speed becomes slower when the Picture is used on the screen This is applicable to HG4G 3G HG2G 5F A specific size of Bitmap is not displayed correctly This is applicable to HG4G 3G HG2G 5F f used with screens overlapping Device range error may not b
21. es would reset when they were outside the specified range Meter needles were not displayed properly Text would not display correctly when Windows fonts were used for the Y axis label on a Line Chart Plotting would stop when the scroll function was used if the number of display points and the scroll step size in a Line Chart were similar lt Host I F Driver gt Additional supported Drivers HG3G MODBUS TCP Server Koyo DirectLogic Ethernet GE Fanuc Automation Series 90 SNP X Keyence KV Ethernet LS Industrial Systems MASTER K VIGOR VB VH YOKOGAWA FA M3 JTEKT TOYOPUC FUJI FREX PC CPU FUJI FREX PC LINK FUJI MICREX F Toshiba PROSEC T Bugs Fixed The following problems have been fixed Timer and counter settings could not be read correctly from IDEC FA3S Communication failed when the MICRO I resetted while communicating with the CPU port of a KEYENCE KV 1000 Series PLC The following issues would occur when a different communication speed was set for COM1 and COM2 SIEMENS S7 MPI Host I F Driver COM2 could not communicate at 187500 bps SIEMENS S7 200 PPI Host I F Driver COM2 could not communicate Keyence KV700 1000 Host I F Driver The communication speed set on COM2 would not reflect correctly when communicating with the CPU port of aKEYENCE KV 1000 Series PLC DM Link 1 1 Host I F Driver COM2 could not perform event transmission MELSEC Q CPU Host I F Driver The communication speed se
22. evices are allocated to Part objects and the other settings dialog box In a Numerical Input and a Numerical Display the number and the unit are not always displayed according to the configured font This is applicable to HG4G 3G and HG2G S 5S 5F A Device Range Error is sometimes shown on the touchscreen if an internal device is set in a script in a project that had been uploaded and re downloaded In a Multi Button when a script command is executed at the beginning of the Function List and View Switching Method is set to Device the image of the switch is not always changed by the value of the allocated device The width and height of a JPG file is shown as 0 0 after it was imported to the Picture Manager This is applicable to HG2G 5S S When the project name is changed in the Explorer tree WindO I NV2 is sometimes unable to open the project This is applicable to HG2G 5S S The Cross Reference dialog box sometimes displays incorrect information for a device having a hexadecimal address If the Host I F driver is MELSEC Q QnA Ethernet the displayed device address in Tag Editor is not correct if the device type is WB WX or WY Part objects are sometimes not displayed on the touchscreen What s New in WindO I NV2 Version 4 61 lt Runtime System Software gt Bugs Fixed The following problems have been fixed a Inthe User Communication function when either Device Registering Constant Character or Hexadecimal is contai
23. ice would be the Timer Contact T or Counter Contact C lt Application Software gt 1 Numerical Input Character Input When Keypad Type is Current Screen and Always Entry Mode check box is ON Reverse check box is masked lt Manual gt 1 Communication Manual Modified the connection diagram 2 and 4 of HG2G in Mitsubishi Modified the connector type of connection diagram 1 in Allen Bradley Modified the connector type of connection diagram 7 in Allen Bradley
24. n fixed You change the O I type or the Host I F driver of the project which contains the scripts written by using tags When you download this project without editing the scripts the scripts do not work properly m When you use the Monitor function on Windows 7 32 bit 64 bit WindO I NV2 crashes under the following conditions 1 In the Properties dialog box of the Word Button Key Button Selector Switch Pilot Lamp Character Input or Picture Display While satisfying the condition is selected as Trigger Type on the Trigger Condition tab and tags are used in the Condition 2 In the Object List window there is the part object which While satisfying the condition is selected as Trigger Type on the Trigger Condition tab next to the above part object 1 If you download an unusual project to the HG2G or the HG3G the commnucations problem arises between the WindO I NV2 and the HGs After you setup the Pilot Lamp on the editing screen the Recover Background check box is always masked when you reopen the Properties dialog box of it What s new in WindO I NV2 Version 4 22 lt Application software gt Bugs Fixed The following problems have been fixed a With Ver 4 21 unknown error occurrs and WindO I NV2 freezes when trying to convert from the HG F HG2S project data to HG3G s a When the O I type is HG3G and the With Unit checkbox of Numerical Input or Numerical Display is selected 1 is always set to the Magnifica
25. n setting a data log a message saying that the data storage area was insufficient would be displayed even if there actually was sufficient free space lt Downloader gt Improvement The following Improvement has been added m The HG3G series is now supported lt Pass Through Tool gt Improvement The following Improvement has been added Now supports pass through between the USB port of HG3G and a MELSEC FX Series PLC lt Manual gt Communication Manual Removed discontinued IDEC PLCs which are FA 3S FA 2J MICRO3 and MICRO3C What s new in WindO I NV2 Version 4 24 lt Runtime System Software gt Bugs Fixed The following problems have been fixed Modified the touch panel driver to fix that the HG1F touch panels didn t always respond Fixed that the settings of MAC Address and LCD size were reset on HG3G if the power was turned off right after the power was applied or the screen was changed to System menu What s new in WindO I NV2 Version 4 23 lt Runtime System Software gt Bugs Fixed The following problem has been fixed HG3G might not be powered up The possibility of this problem depends on each individual unit lt Host I F Driver gt Improvement The following Improvement has been added Improve DM Link 1 1 or DM Link 1 N host I F driver to reduce the influence of scan speed from the driver when large amount of communication happens lt Application software gt Bugs Fixed The following problems have bee
26. ned in a transmission TXD command communication stops and the MICRO I resets m When the Web Server function is used for long periods of time the web server might no longer be accessed by clients The information displayed under Slave Online Status on the Web Server function s System Information System Detailed Information page is not correct lt Host I F Driver gt Bugs Fixed The following problems have been fixed a When Omron SYSMAC CS1 CJ Series Ethernet is selected Host Communication Error appears if Fatal CPU Unit error or Non fatal CPU Unit error happens in the PLC lt Application Software gt Improvements The following Improvements have been added This is applicable to a communication driver Allen Bradley Ethernet IP Logix Native Tag During a tag database L5K and CSV file import a message has been added to alert a user if the tag imported is not supported The customer will have the option to bypass the repeated message and continue with the download of supported tags only Bugs Fixed The following problems have been fixed All settings disappear when projects saved with Ver 4 50 or Ver 4 51 are uploaded with Ver 4 60 This is applicable to HG4G 3G HG2G 5F 5S S a This is applicable to a communication driver Allen Bradley Ethernet IP Logix Native Tag If a project is downloaded after deleting the parts configured with the host device a host communicaiton error may occur on the Touchscreen
27. ollowing problems have been fixed When selecting MODBUS TCP Server with the HG2G 3G the communication is lost if 3 or more clients are connected In addition Communication is lost if cable is connected and disconnected repeatedly When Koyo DirectLogic DL205 405 is selected as Host I F dirver MICRO I can not communicate to the PLC lt Application software gt Improvements The following Improvements have been added Supports 5 7 HG2G 5S 256 color TFT LCD Screen amp HG2G 5F 65K color 8 4 amp 10 4 HG3G w Multimedia and 12 1 HG4G w Multimedia New features or improvements are added from the Runtime System Software upgrade A function that automatically converts the size of parts and draw objects to match the screen size when converting the O I type has been added You can see this option on the Set Conversion Option dialog box after selecting Change O I type A function that compares project data and displays setting differences in screen units has been added To compare projects On the Home tab in the Project group click Compare A function that displays the usage of each script ID in the script manager has been added You can see the usage in the Used column in the Script List An option to download or not download picture and sound data to the memory card simultaneously with the download of project data has been added a When WindO I NV2 closes abnormally it could damage the device address usag
28. on 4 00 The following functions are introduced to WindO I NV2 Version 4 00 New feature Improvement lt Application Software gt 1 Changed New GUI Graphics User Interface Pull down menu and Tool bars were changed to Ribbon Control and allows you to access frequently used commands with minimum steps D Bi C A 7 Sample n2g WindO I NV2 Home Configuration Online View Format B cut Sai aa l Ee baal A zal aul fx Bieu a Copy Bhp Ea New Shapes Picture Text Buttons Lamps Displays Charts Commands Select Arrange uplicate X w x x aS Reuse M 2 Advanced Interactivity for WindCFG and WindLDR WindCFG New System Configuration Software provides the advanced interactivity between WindO I NV2 and WindLDR Those two softwares can share the PLC device address information such as tag name and comments each other automatically 0 Paste 3 Expanded Device address capabilities Tag name is now available Added the cross reference function Device Addresses are set by drag amp drop operation using WindCFG and Tag Editor Expanded the device address format It allows the same as WindLDR The previous WindO I NV2 format is still available The expanded format allows as the separator of bit instead of and the space between Device Type and Address will not be necessary lt Application Software gt 1 Modbus RTU Supported the setting to use No 0 as Broadcast No 2 OpenNet FC3A MicroSm
29. pen Project Fixed that WindO I NV2 crashed if you tried to open the project made with the earlier version and clicked Cancel button on the Save As dialog box after converting it 3 Line Fixed that the setting value did not affect to the display image on the editing window correctly if you changed the value by clicking the up arrow or down arrow button of the coordinates or the size spin box on Format tab 4 Text Fixed that the display image in the editing window differed from the MICRO I when Shadow was selected as Style in the Properties dialog box 5 Parts List Fixed that Parts List was not available when the O I type was HG4F 6 Screen List and Parts List Fixed that nothing was shown in the list after reopening your project after you closed it with the Screen List and the Parts List in auto hide 7 Color Palette Fixed that the Color Palette would change from the 256 colors considering 256 color was the original to the monochrome or vice versa where monochrome is considered as the original after executing the Target Info 8 Batch Monitor Fixed that WindO I NV2 might crash when you tried to close the Batch Monitor after selecting Host as Target lt Downloader gt 1 Read Device Data Write Device Data Increased No of Data from 64 to 2000 2 Upload Log Data Fixed the problem that the uploading of Logging Data with using command line failed in HG1F 2F 2S 3F 4F New functions and enhancements WindOI NV2 Versi
30. r 33 Host I F Network on page 33 13 of the WindO I NV2 User s manual B1119 11 The user communication send and receive data size has been expanded to 1500 bytes This is applicable to HG4G 3G HG2G 5F 5S S For details refer to Chapter 3 Transmission Command Settings Constant on page 3 10 and Chapter 3 Receive Command Settings Constant on page 3 18 of the WindO I NV2 User s manual B1119 11 a 5x 6x 7x has been added to the text magnification This is applicable to HG4G 3G HG2G 5F 5S S For details refer to the Magnification setting of each objects of the WindO I NV2 User s manual B1119 11 The execution interval for the remote monitor amp control has been expanded to a maximum of 5000 milliseconds This is applicable to HG4G 3G HG2G 5F For details refer to Chapter 27 Execution Interval on page 27 3 of the WindO I NV2 User s manual B1119 11 EXA4R is supported The FC5A D12 is now supported with the PLC program transfer function PLC program from an SDmemory card or USB flash drive inserted on the touchscreen This is applicable to HG4G 3G HG2G 5F a The recording function has been improved This is applicable to HG4G 3G For details refer to Chapter 22 Record tab on page 22 14 of the WindO I NV2 User s manual B1119 11 Bugs Fixed The following problems have been fixed Calendar data may have invalid values when using the remote monitoring and remote control functions or cyclic script
31. rlay Screens or Goto Screen button Bugs Fixed The following problems have been fixed a When the host I F driver is Allen Bradley Ethernet IP Logix Native Tag WindO I NV2 may be forcibly terminated if tags are used for device addresses a When multiple objects are selected and moved a portion of the objects may not move to the intended location a Ifthe editing window zoom is set to 100 or more when selecting objects the cursor may move to an unintended location a Create a HG2G S 5S project add a selector switch and close the screen When the screen is opened again the selector switch is displayed in the location 0 0 m When opening a project created with an old version the device information may become invalid m When Picture Manager is opened the thumbnails may disappear What s new in WindO I NV2 Version 4 52 lt Runtime System Software gt Improvements The following Improvements have been added The new password is not requred when transferring a project file from the SD Card USB Flash Drive which contains that new password This is applicable to HG4G 3G HG2G 5F Bugs Fixed The following problems have been fixed m When the Start Time in the Project Settings dialog box is configured you can not monitor the MICRO properly after clicking the Start Monitor in the Monitors group on the Online tab This is applicable to HG4G 3G HG S 5S 5F Remote Control and Monitoring and Port No settings in the We
32. s This is applicable to HG4G 3G HG2G 5F f a shadow style is selected as the drawing object the background color would not display This is applicable to HG4G 3G HG2G 5F Ifa project with Ignore communication errors and continue operation is selected and downloaded to an O I link slave then the Network Offline is displayed and the operation would not work This is applicable to HG4G 3G HG2G 5F 5S S Ifa project with Ignore communication errors and continue operation is selected amp downloaded to an O I link master the O I link slave does not recover from Network Offline if a host communication error occurs This is applicable to HG4G 3G HG2G 5F 5S S lt Host I F Driver gt Additional supported Drivers a Additional supported Drivers YASKAWA MP2000 series Ethernet a Mitsubishi MELSEC Q QnA Ethernet driver communication speed was improved This is applicable to HG4G 3G HG2G 5F 5S S Emerson ROC Protocol driver is not only supported in HG4G 3G and HG2G 5F but also now in HG2G 5S S lt Application Software gt Improvements The following Improvements have been added Changed the Save Screen As shortcut to Ctrl G and assigned the shortcut Ctrl A to Select All New features or improvements are added from the Runtime System Software upgrade a f Zooming Conversion is selected in the Set Conversion Option it will automatically adjust the size of the registered text and coordinates of the screens i e Ove
33. t Recording is enabled even if Auto Play is enabled in the Video Display object This is applicable to HG4G 3G MICRO I may stop if uploading downloading data or changing system mode when it starts playing movie file This is applicable to HG4G 3G When the MICRO I starts running movie file may not be played This is applicable to HG4G 3G If a host device is set to Report when Sampling Count has reached or exceeded Threshold or Report when Space Used has reached or exceeded Threshold in Data Log settings invalid value is written to the device This is applicable to HG4G 3G and HG2G 5F 5S S The display size of the movie file may be smaller than the Video Display This is applicable to HG4G 3G lt Application Software gt Bugs Fixed The following problems have been fixed An NG error can appear if MEMCPY and MEMCMP were used in a script If a NMF file is allocated to a state of the Multi State Lamp it can become Unregistered after overwriting the same file by importing another NMF file to the Picture Manager The Popup Screen No for the Key Button Alt become 1 after closing the Properties dialog box This is applicable to HG4G 3G HG2G 5F and Windows 7 64 bit edition Project Settings dialog box can get a Device empty error and cannnot be closed This is applicable to HG4G 3G and HG2G 5F 5S S The device count in Tag Editor and Cross Reference for devices being used in a script can be corrupted when those d
34. t on COM2 would not reflect correctly lt Application software gt Improvements The following Improvements have been added New features improvements are added from the Runtime System Software upgrade Pictures for the following parts have been added to the Part List and the part library Numerical Input Numerical Display Character Input Message Display Message Switching Display Calendar Meter The option to show or hide script errors a lItis now possible to set scripts to run at set intervals Cyclic Script without affecting screen scan time on screen part processing This is an effective function when using expansion units Bugs Fixed The following problems have been fixed If DPI setting was set to anything other than Normal size under Display Properties in Windows then WindOI NV2 would crash after a new project was created or opened Unusable options would display for the Serial Interface of the host communication protocol depending on the host I F driver a When opening a project created in an old version and converting data to the new version all host device settings used in the project would reset if the new project name contained two or more spaces period ora lf a script was set for a multi button or a multi command and the host device set in the script would not set for any other parts on the same screen then the device value could not be read correctly by the MICRO I Whe
35. then click USB Autorun Definition File Creation Tool lt Manual gt Changed the name of Instruction Manual to User s Manual a United the Hardware Manual to the User s Manual What s new in WindO I NV2 Version 4 32 lt Runtime System Software gt Bugs Fixed The following problems have been fixed The project will fail to download if more than 4MB of project already existed in the HG3G The HG3G can not be controlled by the remote control function when back light is OFF a f Disable Switch option is enabled in Project Settings the HG3G should not be controlled by touch panel and remote control function but it can be controlled from the remote control function The button will not blink if Device is selected as the View Switching Method and the Blink mode is enabled What s new in WindO I NV2 Version 4 31 lt Runtime System Software gt Bugs Fixed The following problems have been fixed m When screen switching occurs during communication with the O I Link O I Link communication errors may occur or the MICRO I may reset However this problem will occur with the HG1F 2F 3F 4F only when using 1 N communication The following are applicable when using the HG3G Series Touchscreen When parts are placed in layers on the screen the layered parts will not be properly displayed The touchscreen will reset depending on the size of the Windows Font lt Application software gt Bugs Fixed The following problems
36. tion settings a Ifthe Fixed Period is selected as the Switching Method of the Picture Display and the Interval is set to the specific value HG3G keeps resetting itself when the screen contains this Picture Display is displayed What s new in WindO I NV2 Version 4 21 lt Application software gt Bugs Fixed The following problems have been fixed a After uploading a project which included 24 bit bitmap from HG3G the bitmap files were corrupted The magnification settings of Numerical Display and Calendar did not change if the O I type was HG3G and the font type was Standard The display value on Numerical Input was garbled if the O I type was HG3G and the font size was 16x16 What s new in WindO I NV2 Version 4 20 lt Runtime System Software gt Improvements m The HG3G series is now supported The following functions have been added to HG3G series Ability to play sound files Ability to display bitmap and JPEG files Ability to display scalable fonts Internal devices for digital input output LEX LEY WLEX and WLEY Ability to change transparency of popup screens The File Copy function The Project Transfer function The PLC Program Transfer function Ability to support external memory devices USB flash drives and SD Memory Cards AutoRun function for USB flash drives A function that allows pictures displayed in the Picture Display to be switched at regular intervals Ability to conn
37. ware gt Bugs Fixed The following problems have been fixed When power on the HG2G 5S it may continue resetting POWER LED keeps blinking a f a host word device is used in popup screen and a bit in the word device is changed in base screen or popup screen an incorrect value may be written to the word device For HG1F 2F 2S 3F 4F this problem only happens when the 1 N Communication is selected as the Connection Type f host bit device is used in the following functions the correct device value can not be read For HG1F 2F 2S 3F 4F this problem only happens when the 1 N Communication is selected as the Connection Type Alarm Data Log Operation Log Reference Device Offset Device Device Monitor function in Web server Monitor function in WindO I NV2 m When the Character Input set as Use as Display for Keypad is used with the HG2G 5F or HG3G 4G the characters are not displayed properly What s new in WindO I NV2 Version 4 42 lt Runtime System Software gt Bugs Fixed The following problems have been fixed a In the HG2G S 5S 5F and HG3G 4G if the following host I F driver is selected in the project MICRO I may stop operation when you cycle power or download upload a project file Modicon Modbus RTU Modicon Modbus ASCII SIEMENS S7 MPI SIEMENS 7 200 PPI Yasukawa MP920 RTU a In the HG2G S 5S 5F and HG3G 4G downloading uploading a project via Ethernet may be failed and then you c
38. xt color of a unit when entering a number This is applicable to HG4G 3G and HG2G 5F 5S S Bugs Fixed The following problems have been fixed The Alarm function in the Calendar object does work properly The alarm bit is turned on and off inconsistently This is applicable to HG4G 3G HG2G 5F When controlling the LEY devices by using an offset in script or Reference Device outputs in the expansion module does not work This is applicable to HG4G 3G HG2G 5F If Reference Device is used in Numerical Input Numerical Display or Character Input the Visible Invisible function and object overlap do not work correctly while the Reference Device value is being changed or while the value is invalid This is applicable to HG4G 3G HG2G 5F If Reference Device is used in a Numerical Input or a Numerical Display and the Visible Invisible condition is changed a Device Range Error could occur This is applicable to HG4G 3G and HG2G 5F 5S S In a Numerical Input and a Character Input if the number or character is set to be displayed as an asterisk the number or character is displayed in the Keypad window This is applicable to HG4G 3G HG2G 5F In a Numerical Input if Current Screen is selected as Keypad Type and Always Entry Mode is enabled data could not be entered properly if the visible invisible condition is changed while entering data This is applicable to HG4G 3G HG2G 5F A move file is not played automatically when Use Even