1. dk 0 Manual User Net Wireless Agricultural Network r December 2012 TABLE OF CONTENTS INTRODUCTION 3 AVAILABILITY OF OLD WAGNET 3 List OF NEW FEATURES 3 SUMMARY OF MANUAL 3 WE WOULD LIKE YOUR FEEDBACK 3 UNIT VIEWS 4 LIST VIEW 4 MAP VIEW 5 SIDEBAR 5 UNIT PAGES 6 FIELD COMMANDER 6 CROP LINK 13 WEATHER TRAC CROP LINK 16 GRAIN TRAC CROP LINK 18 TANK MONITOR CROP LINK 19 PUMP CONTROL CROP LINK 20 SOIL MOISTURE MONITOR CROP LINK 20 AQUATRAC 20 PRECISION LINK 21 PIVOT POINT 22 ACCOUNT MANAGEMENT 28 ACCOUNT INFORMATION 28 ACCOUNT SETTINGS 28 CHANGE YOUR PASSWORD 28 NOTIFICATION CONFIGURATION 29 GROUP SETUP 29 GETTING HELP 30 KNOWLEDGE DATABASE 30 INSTALLATION GUIDES 30 CONTACT US 30 TICKETS OVERVIEW 30 Introduction Page 2 INTRODUCTION AVAILABILITY OF OLD WAGNET LIST OF NEW FEATURES SUMMARY OF MANUAL WE WOULD LIKE YOUR FEEDBACK Introduction Page 3 UNIT VIEWS Our new WagNet site includes three unit views List View Map View and the familiar sidebar Each of these views was available on our old WagNet site but has been drastically improved for our new site List View and Map View can each be located in the View Units menu option at the top of the page LIST VIEW The List View page displays a summary of each Units can be moved from group to group by dragging the unit over the group names m Shared Pivots of your units as a series of dynam
2. Angle Signal Battery 7 Chart loaded successfully Figure 7 Field Commander Chart This tab provides you with a graphical representation of historical data provided by the readings sent from your Field Commander unit Available chart series include Pressure Angle Signal Strength and Battery Available time frames for viewing this data range from one day to a month CONFIG TAB The Config tab give you configure your unit to ensure accurate data readings Please note that inaccurate configuration could result in inaccurate readings The following steps will walk you through the configuration of your Field Commander 1 Enter the name of your unit What you enter here will be the name that shows up describing the unit throughout the WagNet site A descriptive name about its location is best ex Behind Barn to know at all times exactly which unit you are looking at 2 Enter the type of pivot the Field Commander box is installed on We support Valley Lindsay Reinke T amp L and Lockwood specifically If your Field Commander is not installed on one these select Other 3 Selection which direction the pivot runs If your unit runs in a circle then this option should be set as such A pivot that runs side to side is called a lateral pivot and you should choose which direction the pivot runs 4 Enter the length of the pivot in feet This number is used in several calculations involved in 5 Tables and reading
3. A By Month report shows information about the amount of acre inches applied to the entire field by month Note that entering in partial months will result in information returned about the entire month For example a report for 1 15 2013 to 2 15 13 will result a report for 1 1 2013 to 2 28 2013 CMD HISTORY TAB Similar to the Readings tab the CMD History tab provides the information about commands sent to the unit It provides detailed information about what your unit is doing and why Unit Pages Page 11 5 Related Tickets Ticket 33 Preview Ticket Status Open Closed Original Post Posted 02 06 2013 9 33 AM 10 04 2012 2 42 02 04 2013 10 12 AM Matt DeKok Admin 02 06 2013 8 23 This is a test ticket Post a note 1 54 32 rm M GK Paragraph R Z U A 7 E 6 2 2 Words 0 300 Submit Note Figure 9 Tickets Tab First for details about tickets see page 30 This tab gives you access to all of your tickets associated with your units of all types It allows you to make comments post pictures links or videos to us without having to create an email and look back on them in the future The section on the left provides you with a list of your open and closed tickets You can open the ticket in the unit by clicking on the spyglass icon next to the ticket number Clicking on the ticket num
4. Change Group multiple of the same order in which case the units are ordered by other means depending on where you are viewing them The default value for all units is O The last column is the button that when clicked will allow you to move each unit to other groups When you click on the button it will ask you which group number based on column one that you wish to move the units to If you specify a group number that does not exist a new group will be created for you which you can then name whatever you like When you are finished altering the group setup click Save Groups The changes should be immediate Account Management Page 29 GETTING HELP We have a variety of new features for providing you with information you need right on our WagNet site KNOWLEDGE DATABASE The Knowledge Database is a repository for our frequently asked questions It will not be very filled out as of the launch of the new WagNet site but as time progresses we will add more and more content for your needs You can find this page by clicking Help at the top of the page INSTALLATION GUIDES The installation manuals are written by our Director of Engineering Mike Meyer specifically for each type of unit we have They are organized by the year the unit was manufactured So for example if you have a unit manufactured in the year 2013 then you would look at the manuals listed under 2013 You can find this page by clicking Hel
5. by selecting the unit system from the dropdown box below the table name dropdown box This unit system selection will be automatic for users who have set their preferred unit measuring system in their Account Settings page see page 28 for details Another new feature of the speed table is the ability to adjust the entire table s Speed column by a percentage of its current value For example if you had a setting set to 40 duty cycle raising it by 5 would increase it to 42 which is an increase of 5 of 40 Also if you change the values of your Speed Table but decide that you do not like the changes you can click the Reset Speed Table button to reset the table to its original values As of right now the Large Table Configuration and Run Table commands will direct you to a page from old WagNet for these settings The Get Reading command will send an immediate command to the Field Commander unit to send a reading Unit Pages Page 8 CHART TAB FC 31906 showing 1 month Series Pressure ca 4 Angle Signal Strength Time Frame 1 Day 2 Days 1 Week ae 1 Month MI LF When updating graph options give the chart a moment to update Your choices are being U rg par U im par 27 m a U m wi U 14 21 jan 28 saved and the data is being triewed Pressure
6. preferred unit system imperial metric CHANGE YOUR PASSWORD The Change Password page allows you to change your password at any time given that you know your original password If you don t then follow these steps to request a new password 1 Log out of WagNet Click the Forgot button at the top right corner of the page by the Login button 3 Fill in your email address and the human verification box We use the email address you have in your profile to identify your account and send you a new password 4 Click Reset Password When you first log into WagNet we strongly recommend you visit this page to change your password Account Management Page 28 NOTIFICATION CONFIGURATION The Notification Configuration page is a special tool designed to allow you to create up to 10 personalized text message and email alerts when certain conditions are met by your units To setup a text message alert follow these steps 1 The Number field tells you which alert configuration you are looking at You can have up to 10 2 Select either Email or Phone in the Send to dropdown box a Ifyou selected Email enter your email address and click Send Test Message to see if the system is working for you If you selected Phone enter your phone number 1 with no spaces special characters select your carrier and click Send Test Message to see if the system is working for you 3 Silent Period is a sp
7. the unit is moving forward the Change Dir FWD command will be disabled and vice versa for the Change Dir REV command The End Gun table allows you to adjust the angles at Speed which the end gun on your pivot will run There are Always Off Special x three customizable tables that can be renamed and Start Stop Adjust Entire Table two tables called Always On and Always Off In the 10 imperial 8 20 l customizable tables once you have entered your A 0 preferred settings click Save amp Send command to lock By Percent 5 x Speed Up Speed Down in those settings Also click this command to lock in Inches tables when switching between them R i ee 0 0 90 50 0 274 290 180 100 0 137 The Speed Table is much more advanced than its iso 1270 175 10 18 predecessor in old WagNet This new version still 4270 359 35 0 391 so 0 allows you to adjust the table s speed in percentage 80 at various angles from 0 359 Now we have added 70 0 8 an Inches Applied column so that you can adjust your speed tables by how many inches of water you want the Field Commander to apply to each section of field The table will then automatically update the Figure 6 End Gun amp Speed tables and Misc Commands speed required to match that value based on the configuration in the Config tab This column can also be displayed in metric units centimeters
8. Figure 14 Enable Analogs and Digitals Humidity Analogs 1 4 1 Set the corresponding Analog to RHT Hum Only analogs 1 4 support humidity sensors 2 Set the trlo if you want the unit to send a reading when the humidity falls below a certain value 3 Set the trhi if you want the unit to send a reading when the humidity rises above a certain value Temperature Analogs 5 6 1 Set the corresponding Analog to Thermistor Only analogs 5 6 support temperature sensors 2 Set the trlo if you want a reading when the temperature falls below a certain value 3 Set the trhi if you want a reading when the temperature rises above a certain value Wind Direction Analogs 5 6 1 Set the corresponding Analog to Davis Wind Dir Only analogs 5 6 support wind direction sensors 2 Set the trlo if you want a reading when the wind direction bearing falls below a certain value 3 Set the trhi if you want a reading when the wind direction bearing rises above a certain value Wind Speed Digitals 1 2 1 Set the corresponding Digital to Davis Wind Spd 2 Ignore Debounce values or call AgSense Rain Digitals 1 2 1 Set the corresponding Digital to Tipping Bucket 2 Ignore Debounce values or call AgSense Enabled Analog 1 RHT Hum Analog 1 Options trlo 0 trhi 0 Analog 2 Analog 3 Analog 4 Figure 15 Humidity Sensor Analog 6 Thermistor Analog 6 Options trlo 0
9. Post a note I 28 8 in W Paragraph ee E2 Words 0 300 Submit Note Figure 30 Tickets Tab First for details about tickets see page 30 This tab gives you access to all of your tickets associated with your units of all types It allows you to make comments post pictures links or videos to us without having to create an email and look back on them in the future The section on the left provides you with a list of your open and closed tickets You can open the ticket in the unit by clicking on the spyglass icon next to the ticket number Clicking on the ticket number will open the ticket in a new page Unit Pages Page 27 ACCOUNT MANAGEMENT The account management page is where you can update your profile information including username password contact information account settings and notification configuration You can also setup groups to put your units in to organize them on your page and more easily manage them ACCOUNT INFORMATION The Account Information page is where you can update your contact information We strongly recommend you enter your email address We will need this for you to be able to reset your password when you forget it ACCOUNT SETTINGS The Account Settings page has several options you can configure to make your WagNet experience better These options include which page you wish to be directed to when you log in your time zone and your
10. al your pivot is communicating with 0 31 Battery level 4 2V is a fully charged battery e A Pivot Info tab with the following information O O O 0 O If and who it was shared to you by The current power status direction status angle and endgun status The timestamp of the most recent reading generated by the Pivot Point Information about the most recent 2 commands sent to the Pivot Point Information about upcoming timed commands The most recent note entered in the notes tab e A Timed Commands tab listing all currently set timed commands e A Notes tab where you can enter various notes to yourself about the unit Unit Pages Page 22 Below the information panel is a series of tabbed panels CMD Chart Config Readings Report CMD History Tickets The CMD tab displays various command controls you can use to control your Pivot Point unit including Start Stop Change Direction commands Endgun Speed Direction table controls and the ability to request a reading Figure 26 Basic Pivot Point Commands The Start and Stop commands can be used to send an immediate or timed command to start and stop the unit respectively based on the option chosen in the dropdown box to the right of the command The available options are e Now Immediately sends a start stop command the unit e Gives you the option to choose a specific date and time to start stop the unit e Always Gi
11. an be clicked to open the map view for that group UPCOMING FEATURE Soon WagNet s List View page will allow the user to drag and drop their units from group to group Unit Views Page 4 MAP VIEW Groups Map View of Shared Pivots The Map View page is a radical new screen for viewing and managing groups of units at one M time Many new features have been added from tarta our previous Map View to allow you to get a fast an accurate picture of what is happening in your fields A new feature you may notice from Figure 2 3119 62013 62011 Map View is the information bubble over the Figure 2 Map View pivot This bubble displays the most need to A pivot point and its information bubble know information about the unit and a few of the command buttons allowing you to quickly send any needed commands to your unit Other than pivots all other units will display their List View image and its power status There are two ways you can get the information bubble to display The first is to click on the unit in the Groups sidebar The second way is to click on the unit itself in the map On this screen each group displays separately to decrease loading time and increase performance To view another group simply click on the group name in the Groups sidebar SIDEBAR This sidebar represents the list of units that was available to you in our old website It is a list of units org
12. anized by groups with images indicating what the units are and what any pivots are doing Note If you do not see this sidebar it may be because your screen is not wide enough to support displaying it at all times To open the sidebar simply click the View Units item in the menu bar to the right of the WagNet logo This sidebar is designed to give you quick and easy access to any of your units from any page you may be viewing It also provides links to the Map View and to your Group Setup for more detail about Group Setup see page 29 Figure 3 Sidebar Unit Views Page 5 UNIT PAGES The unit pages a series of pages for controlling and monitoring your various units This section explains the various parts of the unit pages for Field Commanders Crop Links of each configuration Aqua Tracs Precision Links and Pivot Points FIELD COMMANDER Serial 31906 Version 30 Shared by bergera Status ON FVVD 106 EndGun OFF Last Reading 02 05 13 9 51 05 AM Current Cycle 61 day 20 hr 30 min Last 2 Commands Pivot Info Command Sent At Config 01 24 13 1 52 46 PM Lonfig 01 23 13 3 25 21 PM Timed Command Timed Commands Google 21 21 22 USDA FS m Service Agence 2 Command Trigger Time Last Note 12 10 12 3 30 56 PM note from api Figure 4 Field Commander Information Panel When you open a Field Commander unit page the first thing you are going to see is an information box like the one seen i
13. ber will open the ticket in a new page Unit Pages Page 12 CROP LINK Because there are many configurations for Crop Links the Crop Link unit page s appearance will vary from configuration to configuration The following five sections Weather Trac Grain Trac Tank Monitor Pump Control and Soil Moisture Monitor explain the various differences those types of Crop Links have in their unit pages The rest of this section will discuss all parts of the unit page that all Crop Links share CHART In most Crop Link unit pages the chart is at the top of the page However in Tank Monitors and Weather Tracs the chart is in a tab and is replaced by a series of graphics illustrating the latest reading information from the Crop Link Berger Test unit showing 1 day Series Units are in US and Imperial messurements El Relay 1 E Relay 2 Battery Time Frame a 1 Day 2 Days 16 00 08 00 Battery 1 Week Highcharts com 9 1 Month Chart loaded successfully Other Auto Zoom When updating graph options give the chart a moment to update Your choices are being saved and the data is being retrieved Figure 10 Crop Link Chart Unit Pages Page 13 MAIN The Main tab is the tab that displays all information about the Crop Link s current status and its commands All Crop Links have a Get Reading command which requests a reading from the Crop Link unit Each Crop Link can have tw
14. ding generation so please make sure this number is as accurate as you can get it The External 1 and External 2 fields are set by AgSense call 1 605 352 8350 for details Enter the conditions for speed and end gun usage Click Save Settings and then proceed to the instructions below to set your pivot 5 GPS location Now that you have your Field Commander configured to the correct settings the next step is to set the GPS location on the map at the bottom of the Config tab For circle pivots 1 Enter the GPS coordinates of the center of your pivot in the text boxes provided for latitude and longitude Coordinates must be entered in decimal degrees If you wish to adjust the zoom setting feel free to do so This setting adjusts the zoom level for the map image in the information panel at the top of the page Click Center on Map A marker should appear on the map In the map provided if the marker is not exactly over the center location of your pivot you can fix it by clicking on the map where the center should be Click Save Settings again to save the GPS coordinates Unit Pages Page 10 For lateral pivots 1 Enter the GPS coordinates of the center of your pivot in the text boxes provided for latitude and longitude Coordinates must be entered in decimal degrees 2 If you wish to adjust the zoom setting feel free to do so This setting adjusts the zoom level for the map image in the information panel at the top of th
15. e page 3 Click Center on Map This will position the map to where your pivot is Unlike a circle pivot a marker will not appear on the map 4 Starting in the Northwest corner of the pivot area and going clockwise in each of its corners click on the map to mark the four corners of your lateral pivot s operation area Once the fourth marker is placed the configuration will automatically save and refresh the unit page READINGS TAB This tab provides the historical data sent by the Field Commander unit It provides you with detailed information about what your unit is doing TT start Date 2 74 0 2013 REPORT The report tab provides a highly detailed report of your unit s reading data You can generate or Stop Date 2 5 2013 print three types of reports for a specified period Report Type Event 6 By Angle By Month of time The three report types are an event Generate Print report an inches applied by angle report or an inches applied by month report Figure 8 Report Options An Event report is a report that displays tabular information about the change in the Field Commander s power direction status and pump status and the duration of those periods of activity A By Angle report is more graphical and displays two graphs of the amount of acre inches applied to each angle degree of the pivot area in a circular pivot The report also displays tabular information for each of those angle ranges
16. ecial optional field that will allow you to configure a time of day when you do not wish to receive any alerts Once you have these options selected you can customize your alert for each individual unit or as a group by unit type After you have done that scroll to the very bottom and click Update GROUP SETUP Assign each unit a number Units will be ordered by ascending order The Group Setup page allows you to place your units into groups to keep a more organized workspace on WagNet By default your units will appear in a group called Group 0 The first column in Group Setup is the group number Groups will be ordered throughout WagNet based on this field The second column is the group name and will be how the group is identified throughout WagNet The third column is the list of units by alias serial number in each group The fourth column is a number by which the units are ordered in the groups They do not have to be exactly sequential You can also have Group Group Name 0 Shared Pivots Shared Crop Links Shared Tank Monitors 3 Shared Aquatracs Shared unit Figure 31 Group Setup Units Demo FC s Berger 27284 PP s FC 31906 s 42077 s AgSense Weather 5 FC 31906 Outdoor Tank 1 Outdoor Tank 2 5 Outdoor Tank 3 5 Mid and 5 trees 5 Save Groups Change Group Change Group Change Group Change Group Change Group Change Group Change Group Change Group Change Group
17. ection which direction the pivot runs Unit Pages Page 24 10 11 12 If your unit runs in a circle then this option should be set as such A pivot that runs side to side is called a lateral pivot and you should choose which direction the pivot runs Enter the length of the pivot in feet This number is used in several calculations involved in 5 Tables and reading generation so please make sure this number is as accurate as you can get it Enter the distance your pivot s end gun reaches This number is used in several calculations involved in Speed Tables and reading generation so please make sure this number is as accurate as you can get it For circle pivots Enter the minimum angle of the unit s operation Remember that O degrees represents straight North This number is used in several calculations involved in Speed Tables and reading generation so please make sure this number is as accurate as you can get it For circle pivots Enter the maximum angle of the unit s operation Remember that 0 degrees represents straight North This number is used in several calculations involved in Speed Tables and reading generation so please make sure this number is as accurate as you can get it Enter the time it takes for the pivot to complete one revolution at 100 duty cycle speed This number is used in several calculations involved in Speed Tables and reading generation so please make sure this number is as accu
18. generation so please make sure this number is as accurate as you can get it 5 Enter the distance your pivot s end gun reaches Unit Pages Page 9 10 11 12 13 14 15 16 This number is used in several calculations involved in Speed Tables and reading generation so please make sure this number is as accurate as you can get For circle pivots Enter the minimum angle of the unit s operation Remember that O degrees represents straight North This number is used in several calculations involved in Speed Tables and reading generation so please make sure this number is as accurate as you can get it For circle pivots Enter the maximum angle of the unit s operation Remember that O degrees represents straight North This number is used in several calculations involved in Speed Tables and reading generation so please make sure this number is as accurate as you can get Enter the time it takes for the pivot to complete one revolution at 100 duty cycle speed This number is used in several calculations involved in Speed Tables and reading generation so please make sure this number is as accurate as you can get Enter the type of pressure sensor being used Enter the low pressure Enter the high pressure Enter the voltage at O PSI 0 5 volts is the correct normal value Enter the estimated flow in gallons per minute This number is used in several calculations involved in Speed Tables and rea
19. howing 1 day In this type of Crop Link the chart has been moved to a tab below the gauges The chart has additional series for the historical data represented by each of the gauges in the top es Tank Monitor 1 Month panel For example in Figure 22 Tank Monitor Chart loaded successfully l Other 1 Auto Zoom Chart you ll notice that the series of this chart include Tank Monitor1 These names represent 21 saved and the data is being retrieved the type of sensor on the crop link and the port it Figure 22 Tank Monitor Chart is connected to Unit Pages Page 19 CONFIG TAB Before configuring a crop link as a Tank Monitor you ll need to set it up as a generic Crop Link See page 14 for instructions on generic Crop Link configurations Once you ve finished those instructions the following instructions will set up the crop link as a Tank Monitor Analog Enabled Analog 1 Tank Monitor l Analog 1 Options Tank Alias Outdoor Tank 1 Specific Gravity of Fluid in Tank 1 0625 Tank Diameter 0 ft 2 in Tank Height 30 ft O in Sensor distance from bottom oftank 0 ft O in Set Location Figure 24 Example Tank Monitor Configuration If Analog is set to Disabled set to Enabled 2 Set the corresponding Analog setting to Tank Monitor A series of fields should appear 3 Fill out the Analog Options fields as accurately as you can 4 Repeat steps 2 and 3 for all connected Tank Monitori
20. ic images w 768 designed to load the information for each of ROZNE e Shared Crop Links AgSense Heather f1 40 R2 N A A Ad N A 85 86 17 your units 81 14 13 13 44 36 The information loaded depends the type of shared tank Monitors 4 Outdoor Tank 1 r 61 25 2 a oz 2 2 unit being displayed 37 S JE IA ur 01 14 13 13 52 47 e Pivot units of various types Field pas Commanders Pivot Points and mi 9 st 1 M 01 14 13 14 49 47 Precision Links display a graphic Figure 1 List View representation of the pivot the power From top to bottom left to right a Pivot Point a Field status current direction current angle Commander a Precision Link a Crop Link a Tank Monitor current speed current pressure and Crop Link displaying three tanks an Aquatrac latest reading time e Crop Links display the latest reading information about the various analogs installed on them and the latest reading time e Tank Monitors which are a special type of Crop Link display the same information as the Crop Links in addition to a graphic gauge indicating its current level e Aquatracs Clicking on a unit will open that unit s control panel See page 6 for more information on the unit control panels The units are also organized based on your current group configuration See page 29 for more information about group setup The group names in the group header bars c
21. in Board Enabled Bin Num Cable Mum Board Number Start Sensors Num Sensors Delete Figure 21 Grain Bin Board Configuration REPORT TAB Similar to the Chart tab the Report tab also has added columns in the report to display historical data for each of the analog and digital sensors on the Crop Link Unit Pages Page 18 TANK MONITOR CROP LINK Tank Monitors Crop Links are displayed somewhat differently in WagNet When a single unit is configured for multiple tanks each will be displayed as a separate unit The unit page for each tank displays information for each individual unit For information on how to configure a Tank Monitor Crop Link for multiple tanks see page 20 CHART In most Crop Link unit pages the chart is at the top of the page However in Tank Monitors and Weather Tracs the chart is in a tab and is replaced by a series of graphics illustrating the latest reading information from the Crop Link When your Tank Monitor Crop Link unit page loads you ll notice that the top of the page is no longer a chart but rather a series of gauges displaying the latest reading data graphically In old WagNet this information was given to you as text in the Main tab however in our new WagNet site we have upgraded this to a graphic display as shown in Figure 23 Tank Monitor Reading Display Tank Monitor TM 1 i FF 1O Gin 1 29 gallons Figure 23 Tank Monitor Reading Display Outdoor Tank 1 s
22. ion commands Endgun Speed table controls Run table controls and the ability to request a reading Figure 5 Basic Field Commander Commands The Start and Stop commands can be used to send an immediate or timed command to start and stop the unit respectively based on the option chosen in the dropdown box to the right of the command The available options are e Now Immediately sends a start stop command the unit e Gives you the option to choose a specific date and time to start stop the unit e Always Gives you the option to choose a specific time to start stop the unit every day e Clear Clears all once always timed start stop commands The Start FWD and Start REV commands allow you to send an immediate start command to start the pivot in the direction of your choice The Stop Angle command allows you to send a timed command to the Field Commander to stop the unit at a specified angle You can also use the dropdown box to the immediate right of the command to clear the timed command The Change Dir FWD and Change Dir REV commands can be used to send an immediate command to the unit to change its current direction Also note that when the unit is powered off all of these commands will be disabled until the unit is powered on When the unit is on and idle the stop commands will be disabled When the unit is on and Unit Pages Page 7 moving the start commands will be disabled When
23. n Figure 4 Field Commander Information Panel at the top of the page containing the following e Animage displaying the current activity and status of the pivot with numerical details at the bottom of o Angle 0 degrees is straight North Speed in percentage of maximum Pressure the current water pressure GPS signal status WAAS is best Basic is okay None means no GPS reading Signal strength the strength of the signal your pivot is communicating with 0 31 o Battery level 4 2V is a fully charged battery e A Pivot Info tab with the following information o Serial and version numbers o If and who it was shared to you by o current power status direction status angle and endgun status O O Unit Pages Page 6 The timestamp of the most recent reading generated by the Field Commander The amount of time the Field Commander has been on its current cycle Information about the most recent 2 commands sent to the Field Commander O O O O Information about upcoming timed commands o The most recent note entered in the notes tab e A Timed Commands tab listing all currently set timed commands e A Notes tab where you can enter various notes to yourself about the unit Below the information panel is a series of tabbed panels CMD Chart Config Readings Report CMD History Tickets The CMD tab displays various command controls you can use to control your Field Commander unit including Start Stop Change Direct
24. n decimal degrees If you wish to adjust the zoom setting feel free to do so Unit Pages Page 25 This setting adjusts the zoom level for the map image in the information panel at the top of the page 3 Click Center on Map This will position the map to where your pivot is Unlike a circle pivot a marker will not appear on the map 4 Starting in the Northwest corner of the pivot area and going clockwise in each of its corners click on the map to mark the four corners of your lateral pivot s operation area Once the fourth marker is placed the configuration will automatically save and refresh the unit page CHART TAB Berger 27284 PP showing 1 day Pressure Location Signal Strength an Time Frame oO 1Day 2 Days 1 Week 1 Month o a uw 20k m BL 20 00 6 Feb 04 00 08 00 12 00 WET NTAE GP EERTE give the chart a moment to Pressure Location update Your choices are being saved and the data is being Chart loaded successfully Figure 28 Pivot Point Chart This tab provides you with a graphical representation of historical data provided by the readings sent from your Pivot Point unit Available chart series include Pressure Angle and Signal Strength Available time frames for viewing this data range from one day to a month READINGS TAB This tab provides the historical data sent by the Pivot Point unit It provides you with detailed information about wha
25. ng sensors 5 Click Save Settings REPORT TAB Similar to the Chart tab the Report tab also has added columns in the report to display historical data for each of the analog and digital sensors on the Crop Link PUMP CONTROL CROP LINK SOIL MOISTURE MONITOR CROP LINK AQUATRAC Unit Pages Page 20 PRECISION LINK Unit Pages Page 21 PIVOT POINT Google je USDA F gt m Service Agency Shared by none Status ON FWD 272 Endgun ON Last reading 02 06 13 6 35 AM CST Last 2 Commands Pivot Info Command Sent At Change Direction 02 05 13 11 03 PM Change Direction 02 05 13 11 03 PM Timed Commands Timed Command Command Trigger Time Last Note 05 03 12 12 43 34 AM This note 15 a test Figure 25 Pivot Point Information Panel As you can see the Pivot Point unit page is almost identical to the Field Commander unit page When you open the unit page the first thing you are going to see is an information box like the one seen in Figure 25 Pivot Point Information Panel at the top of the page containing the following e An image displaying the current activity and status of the pivot with numerical details at the bottom of O Angle 0 degrees is straight North Speed in percentage of maximum Pressure the current water pressure GPS signal status WAAS is best Basic is okay None means no GPS reading Signal strength the strength of the sign
26. o relays When relays are enabled in the Config tab see page 14 two commands will appear on the Main tab that allow you to turn the relays on and off Additional information will be displayed here for other types of Crop Links CONFIG TAB The Config tab is how you configure a Crop Link to be whatever type of Crop Link you want it to be This guide will walk you through step by step how to set up each part of the configuration that is not related to those options but for generic Crop Links Configuration instructions for each type of Crop Link other than generic types will be given in their corresponding sections 1 Enter the Name of your unit What you enter here will be the name that shows up describing the unit throughout the WagNet site A descriptive name is best ex Outdoor Tank to know at all times exactly which unit you are looking at 2 If your unit has relays set the Relays field to Enabled A few more options will appear to configure the relays The following sub instructions will walk you through configuring them a Enter a name for relay 1 This step is optional If blank the relay name will default to Relay 1 b Check Momentary if the relay is momentary c Check Continuous if the relay is continuous Check Disable if you do not wish to use the relay Repeat steps a d for Relay 2 READINGS TAB Unit Pages Page 14 This tab provides the historical data sent by the Field Commander unit It provides you
27. p at the top of the page CONTACT US Most of the time you can contact us at our phone number 1 605 352 8350 but if you can t get a hold of us due to holiday or other reasons please feel free to click the Contact Us link at the top of the WagNet page and send us an email TICKETS OVERVIEW One of our biggest new features is our Ticket system One of your concerns might be that this is a take a number system but believe us it is not This system provides us a way to keep track of conversations requiring multiple phone calls over periods of time They can also be updated and monitored by you our users If you have tickets you can view them at any time even if they have already been resolved by visiting your account page and clicking on My Tickets in the menu on the left side of the screen Both you and our support agents can assign units to the ticket which will then allow you to view the ticket in the unit pages see page 12 for those units Our advanced comment editor allows you to post more than just text comments in the ticket You also have the ability to post pictures videos and links from the Web Getting Help Page 30
28. predecessor in old WagNet This new version still 1 Speed Direction allows you to adjust the table s speed in percentage 3 quarters increasing NH persistant at various angles from 0 to 359 Now we have added ae an Inches Applied column so that you can adjust Stat 90 Adjust Entire Table 270 Fwd 180 Unit System Imperial Rev your speed tables by how many inches of water you gt os Reset Speed Table Stop want the Pivot Point to apply to each section of field Stop By Percent 5 gt The table will then automatically update the speed Speed Up Speed Down Stop Stop required to match that value based on the Stop Speed Applied Stop configuration in the Config tab This column can also 15 115 20 154 di tri it timet 7 215 125 30 0 77 e displayed in metric units centimeters by selecting the unit system from the dropdown box 435 55 50 0 462 8 5 2 below the table name dropdown box This unit gt 0 system selection will be automatic for users who To have set their preferred unit measuring system in their Account Settings page see page 28 for details Figure 27 End Gun amp Speed tables and Misc Commands Another new feature of the speed table is the ability to adjust the entire table s Speed column by a percentage of its current value For example if you had a se
29. rate as you can get it Enter the estimated flow in gallons per minute This number is used in several calculations involved in Speed Tables and reading generation so please make sure this number is as accurate as you can get it Select the type of pressure sensor being used and enter the voltage at O PSI and 100 PSI 0 5 volts is the correct normal value for PSI and 4 5 is the correct normal value for 100 PSI Click Save Settings and then proceed to the instructions below to set your pivot s GPS location Now that you have your Field Commander configured to the correct settings the next step is to set the GPS location on the map at the bottom of the Config tab For circle pivots 1 Enter the GPS coordinates of the center of your pivot in the text boxes provided for latitude and longitude Coordinates must be entered in decimal degrees If you wish to adjust the zoom setting feel free to do so This setting adjusts the zoom level for the map image in the information panel at the top of the page Click Center on Map A marker should appear on the map In the map provided if the marker is not exactly over the center location of your pivot you can fix it by clicking on the map where the center should be Click Save Settings again to save the GPS coordinates For lateral pivots 1 Enter the GPS coordinates of the center of your pivot in the text boxes provided for latitude and longitude Coordinates must be entered i
30. t your unit is doing REPORT TAB The report tab provides a highly detailed report of stat Date 2 4 2013 your unit s reading data You can generate Stop Date 2 5 2013 print two types of reports for a specified period of Report Type Event By Angle By Month time The two report types are an inches applied Generate Print by angle report and an inches applied by month Generate report Figure 29 Report Options Unit Pages Page 26 A By Angle report is more graphical and displays two graphs of the amount of acre inches applied to each angle degree of the pivot area in a circular pivot The report also displays tabular information for each of those angle ranges A By Month report shows information about the amount of acre inches applied to the entire field by month Note that entering in partial months will result in information returned about the entire month For example a report for 1 15 2013 to 2 15 13 will result a report for 1 1 2013 to 2 28 2013 CMD HISTORY TAB Similar to the Readings tab the CMD History tab provides the information about commands sent to the unit It provides detailed information about what your unit is doing and why TICKETS TAB Related Tickets Ticket 33 Preview Ticket Status Open Closed Original Post Posted 02 06 2013 9 33 AM 10 04 2012 2 42 02 04 2013 10 12 Admin 02 06 2012 2 22 This is a test ticket
31. tab and is replaced by a series of graphics illustrating the latest reading information from the Crop Link When your Weather Trac Crop Link unit page loads you ll notice that the top of the page is no longer a chart but rather a series of gauges displaying the latest reading data graphically In old WagNet this information was given to you as text in the Main tab however in our new WagNet site we have upgraded this to a graphic display as shown in Figure 12 Weather Trac Reading Display Temperature Wind Direction Wind Speed Wind Gust Temp6 Wind Dir5 i 2 L ta a W D mph 11 27 kmph Figure 12 Weather Trac Reading Display In this type of Crop Link the chart has been moved AgSense Weather showing 1 day to a tab below the gauges The chart has additional i series for the historical data represented by each of the gauges in the top panel For example in Figure 7 13 Weather Trac Chart you ll notice that the WndSpdl series of this chart include Hum1 Wind Dir5 Chart loaded successfully Temp6 WindSpd1 and Rain2 These names represent the type of sensor on the crop link and the port it is connected to Figure 13 Weather Trac Chart Unit Pages Page 16 CONFIG TAB All weather sensors are analog and digital sensors So the first thing you need to do is make sure they are enabled Analog Enabled
32. trhi 0 Figure 16 Temperature Sensor Analog 5 Davis Wind Dir Analog 5 Options trlo 0 trhi 0 Figure 17 Wind Direction Sensor Digital 1 Davis WS Figure 18 Wind Speed Sensor Digital 2 Tipping Bucket Figure 19 Tipping Bucket Sensor Unit Pages Page 17 REPORT Similar to the Chart tab the Report tab also has added columns in the report to display historical data for each of the analog and digital sensors on the Crop Link GRAIN TRAC CROP LINK Grain Tracs Crop Links are displayed somewhat differently in WagNet When a single unit is configured for multiple grain bins each will be displayed as a separate unit The unit page for each bin displays information for each individual unit For information on how to configure a Grain Trac Crop Link for multiple bins see page 18 MAIN TAB The Main tab is the tab that displays all information about the Crop Link s current status and its commands All Crop Links have a Get Reading command which requests a reading from the Crop Link unit Each Crop Link can have two relays When relays are enabled in the Config tab see page 14 two commands will appear on the Main tab that allow you to turn the relays on and off The Main tab in a Grain Trac Crop Link unit page will also contain the chart of readings from the unit s sensors and cables as shown in Figure 20 Grain Trac Data Figure 20 Grain Trac Data CONFIG TAB Grain B
33. tting set to 40 duty cycle raising it by 5 would increase it to 42 which is an increase of 5 of 40 Also if you change the values of your Speed Table but decide that you do not like the changes you can click the Reset Speed Table button to reset the table to its original values The Direction table allows you to set a change in direction at various points during the current cycle In Field Commanders this was replaced by the Run Table However as of right now the Large Table Configuration and Run Table commands are only available for Field Commanders The Get Reading command will send an immediate command to the Pivot Point unit to send a reading CONFIG TAB The Config tab give you configure your unit to ensure accurate data readings Please note that inaccurate configuration could result in inaccurate readings The following steps will walk you through the configuration of your Field Commander 1 Enter the name of your unit What you enter here will be the name that shows up describing the unit throughout the WagNet site A descriptive name about its location is best ex Behind Barn to know at all times exactly which unit you are looking at 2 Enter the type of pivot the Field Commander box is installed on We support Valley Lindsay Reinke T amp L and Lockwood specifically If your Pivot Point is not installed on one these select Other 3 Ifyou have a T amp L unit please select it for the Display Type 4 Sel
34. ves you the option to choose a specific time to start stop the unit every day e Clear Clears all once always timed start stop commands The Start FWD and Start REV commands allow you to send an immediate start command to start the pivot in the direction of your choice The Stop Angle command allows you to send a timed command to the Pivot Point to stop the unit at a specified angle You can also use the dropdown box to the immediate right of the command to clear the timed command The Change Dir FWD and Change Dir REV commands can be used to send an immediate command to the unit to change its current direction Also note that when the unit is powered off all of these commands will be disabled until the unit is powered on When the unit is on and idle the stop commands will be disabled When the unit is on and moving the start commands will be disabled When the unit is moving forward the Change Dir FWD command will be disabled and vice versa for the Change Dir REV command The End Gun table allows you to adjust the angles at which the end gun on your pivot will run There are three customizable tables that can be renamed and two tables called Always On and Always Off In the customizable tables once you have entered your preferred settings click Save amp Send command to lock in those settings Also click this command to lock in tables when switching between them Unit Pages Page 23 The Speed table is much more advanced than its
35. with detailed information about what your unit is doing REPORT TAB The Report tab gives you a summarized table of information from the readings for a specified date range that you can generate or print NOTES TAB This tab allows you to enter notes to yourself about a unit It will automatically be timestamped TICKETS TAB Related Tickets Ticket 33 Preview Ticket Status Open Closed Original Post ESAE E E Posted 02 06 2013 9 33 AM Admin This is a test ticket 02 04 2013 10 12 Matt DeKok 02 06 2013 8 33 Post a note JL 5 2 arm GS Gy W Paragraph 1 1 2 5 i lt lt 62 2 Words 0 300 Submit Note Figure 11 Tickets Tab First for details about tickets see page 30 This tab gives you access to all of your tickets associated with your units of all types It allows you to make comments post pictures links or videos to us without having to create an email and look back on them in the future The section on the left provides you with a list of your open and closed tickets You can open the ticket in the unit by clicking on the spyglass icon next to the ticket number Clicking on the ticket number will open the ticket in a new page Unit Pages Page 15 WEATHER TRAC CROP LINK CHART In most Crop Link unit pages the chart is at the top of the page However in Tank Monitors and Weather Tracs the chart is in a