1. FAKRO Z Wave Controll ZWP1 0 User Manual 2 a ot CE www fakro com Dear Sir Madam Thank you for purchasing product from FAKRO Company We do hope that it will meet your expectations To provide appropriate functioning of the product please read this User Manual Contents Information about the Product ccccccssssseseeceeeeeeeeeeeceeceseeueeeeeeeeeeeasaeauaaeaeaeeeeeneneess 3 Packaging content eee eee aaa aaa aaa aaa aaa iaer ei aaa aaa aaa near 3 Technical dala saa ko O WE A ada awk EEE Ep 3 Product description s sasas ass ae aa aeriene aeda oi EE en isai aads 3 Controll MOSS iris angre WOS O RO e eee 4 General information about the Z Wave system c cccccceceeeeeeeeeeeeeteeeeeeteeeeeeetees 5 General information ua ER RAE PE ad aka Pad PGL 5 Basic functions of the Z Wave system eueeo sean aaa aaa aaa aaa aaa 5 Sample scheme of the Z Wave network seeeeeaaa nana aaa aa aa aaa aa zaa aaa aaa enken 5 Preparing controller for programming e see eee eee ener 6 Controller programming quick configuration eee eee aaa aaa aaa acc 7 Adding device to the controller and buttons of movement 1 111 T Controller programming basic functions 0 ccccccecceeeceeee ee eeeteeeeeeeeeeenneeeeeeeneees 8 Adding device to the controller INCLUDE
2. ccccceeceeeeeeeeeeeeeeseeeeeeteeeeeeeaeees 8 Adding device only to buttons of movement ASSOCIATE 1 2 2 11111 8 Adding another controller to the Z Wave network LEARN MODE 9 Removing device from the controller EXCLUDE eeeeaaaaa aaa aaaaa ca neee 10 Restoring the controller to factory settings DEFAULT 2 2 2 21122 10 Removing one device from buttons of movement DELETE 11 Removing group of devices from given buttons of movement DELETE 11 Controller programming additional functions eeeeueae aaa mr 12 Adding remote device to the Z Wave network ASSIGN A ROUTE 12 Associating Z Wave devices ASSOCIATE DEVICE sessuuss1aseas22 13 Copying group of devices COPY GROUP 0 ccceececeeeeeeeeeeeeeseneeeeeeeteseaeeeeees 13 Range of Z Wave devices ccccccccccecceee cece auc 14 Range of Z Wave devices depending on the surrounding environment 14 Packaging content Remote control Magnetic wall holder User manual Batteries 2 x AAA 1 5V Mounting screws Technical Data Power supply 3V DC Battery 2xAAA 1 5 V Operation temperature 5 C to 40 C Range of operation in the open space up to 40 m Wireless Protocol 868 4 Mhz EU 921 42 MHz AS NZ 908 4 MHz US Can
3. 1 2 3 will light up on the controller Otherwise procedure must be performed again Adding remote device to the Z Wave network ASSIGN A ROUTE Function allows for adding already installed Z Wave device to SECONDARY controller permanently installed e g ZWMP or ZWMA weather module via PRIMARY controller transferring Node INFO Such situation occurs when device SECONDARY controller and controlled device are not in direct contact with each other or time to perform ASSOCIATE procedure is too short Within 1 sec press IN EX button and once SELECT button on PRIMARY controller LEDs 1 and 2 will light up Within 10 sec press P button on the device until LEDs on the controller change into 3 and 4 On the target controller SECONDARY e g ZWMA module within 60 sec choose channel and perform ASSOCIATE function within 1 sec press IN EX button and button of movement of a given group until LED s 1 2 3 light up Target controller signals accepting the Node INFO by the change of LEDs for 2 3 4 and on PRIMARY controller LEDs 1 2 3 4 light up If a given sequence of LEDs does not occur it is necessary to perform procedure again 2 3 4 1 2 3 4 t lt is I In Ex Select w SECONDARY PRIMARY Associating Z Wave devices ASSOCIATE DEVICE Function allows for such configurati
4. ready to operate Note If one omits step 2 that is pressing button of movement the device will be added only to the network see INCLUDE function Then to be able to operate the device it is necessary to add it to buttons of movement with the use of ASSOCIATE function In order to add another device to the same or other group it is necessary to perform above procedure again Adding device to the controller INCLUDE Adding device only to the controller s memory is required if the user wants device to be in the Z Wave network and operated e g only by subordinate controller SECONDARY Press once IN EX button on the controller LEDs 1 and 4 will light up Within 10 sec press P button on the device until the network status LED is off see device programming manual Controller signals device correct adding by lighting of LEDs 2 and 3 Controller signals device incorrect adding by blinking of LEDs 1 and 4 and the procedure should be performed again Adding device only to buttons of movement ASSOCIATE If device has already been assigned to the controller for buttons of movement group it can be added to another group with the use of ASSOCIATE function Choose one of 5 channels on which the device is to be assigned Within 1 5 sec press once IN EX button and once button of movement of a given group to which device is to be added LEDs 1 2 3 will light up W
5. LUDE procedure on devices and assign them again Within 1 sec press twice IN EX button and once SELECT button until LEDs 2 3 1 4 2 3 blink If a given sequence of LEDs does not occur it is necessary to perform procedure again DEFAULT function will set the SECONDARY controler again as the PRIMARY controller DEFAULT Removing one device from buttons of movement DELETE Function is used for removing particular device from buttons of movement without removing it from the network Choose channel on the controller from which the device is to be removed Within 1 5 sec press twice IN EX button and once one of buttons of movement of a given group LEDs 1 2 3 will light up Within 10 sec press P button on the device and hold until LEDs on the controller change into 1 2 3 Controller signals error by blinking of LEDs 2 3 4 and procedure must be performed again Removing group of devices from buttons of movement DELETE This function is used for removing all devices from buttons of movement of a given group without removing them from the network Choose channel on the controller from which group of devices is to be removed Within 1 5 sec press twice IN EX button and once any button of movement of a given group until LEDs 1 2 3 light up Within 10 sec confirm removing devices by pressing STOP button of a given group LEDs
6. ada Sizes length width height 157 38 19 mm Operation frequency Product description The ZWP10 controller enables radio control of FAKRO electrical accessories and of other manufacturers that are compatible with the Z Wave system The ZWP10 controller operates up to 10 devices separately on 5 channels 2 devices for 1 channel It also allows for creation of 10 independent groups Each group can include several devices operated simultaneously Controller s memory can contain up to 231 devices The ZWP10 controller is equipped with a two way Z Wave radio communication module exploiting radio wave frequency frequency depending on the country for which the product is intended It can be used as the basic controller PRIMARY as well as an additional SECONDARY PRIMARY controller allows for integration of many devices into one radio network while SECONDARY is used as an additional controller in already existing network see LEARN MODE function In addition to Basic Mode of operation OPEN STOP CLOSE the ZWP10 controller offers Multilevel Mode allowing for e g smooth dimming of the light LEDs signalling active channel 1 channel 1 2 channel 2 3 channel 3 4 channel 4 1 2 3 4 channel 5 Button of SELECT channel choice Buttons of MOVEMENT operate single device or group of devices OPEN STOP CLOSE Groups of controlled devices group 1 2 channel 1 group 3 4 channel 2 group 5 6 channel 3
7. anty period is 24 months from the purchase date fulfilling the following conditions Installation has been performed by an authorised individual as per manufacturer recommendations Seals remain intact and no unauthorised structural changes have been made The device has been used in accordance with its intended use as per user manual Damage is not a result of improperly made electrical system or atmospheric phenomena e The manufacturer is not liable for damage which occurred as a result of improper use or mechanical damage In case of failure the device must be submitted for repair with a Warranty Card Defects revealed within the warranty period will be removed free of charge no longer than 14 days after accepting the product for repair Warranty and post warranty repairs are performed by the manufacturer i e FAKRO PP Sp z 0 0 Quality Certificate Device Serial NUMDEL c0ccececeeeeeeceeaesseeeeeeeeeeeeeeeeeaas DCMS Fi E EE A ETT Addres Se en en an eE A Ad CA Date Of PUrChaS cccesceeseceeeeeeseseeeaeeseeeeeeeeneees Signature stamp of installing person FAKRO PP Sp zo o ul Wegierska 1 44A 33 300 Nowy Sacz Polska www fakro com tel 48 1 8 444 0 444 fax 48 1 8 444 0 333 14 03 12 NC851 GB 2014 FAKRO
8. cur it is necessary to perform procedure again Range of Z Wave devices depending on the surrounding environmenta Radio signal range depends on the type of construction the materials used and the Z Wave devices location Penetration of the radio signal in different materials 1 Brick wall 60 90 2 Reinforced concrete 20 60 3 Wooden structures of gypsum cardboard 80 95 4 Glass 80 90 5 Metal walls 0 10 Declaration of Conformity in accordance with directive 2006 95 EEC We FAKRO Sp z 0 0 144a W gierska St declare that the product ZWP10 controller e is compliant with the requirements of 2004 108 EEC directive concerning electromagnetic compatibility is compliant with the requirements of 1999 5 EEC directive concerning radio devices and final telecommunication equipment and mutual recognition of their conformity e is compliant with the requirements of 2006 95 EEC directive concerning electric equipment designed for use within certain voltage limits has been manufactured according to harmonized standards PN EN 300220 2 PN EN 301489 3 PN EN 55014 1 PN EN 55014 2 PN EN 60335 2 97 PN EN 60335 1 Sp Z0 0 Michal Hajduga Zarz dzanie Produktami Nowy S cz dnia 111 12 04 2010 Warranty The manufacturer guarantees correct device functioning It also undertakes to repair or replace the device if its defects result from material or structural faults The warr
9. er can be performed by controllers from different companies complying with Z Wave protocol To set the SECONDARY controller as PRIMARY again perform the DEFAULT function Removing device from the controller EXCLUDE If the user wants to completely remove device from the Z Wave network reset HomelD e g in order to assign to another controller below presented procedure must be performed But one should bear in mind that this procedure will remove device from buttons of movement and controller s memory Press twice IN EX button within 1 sec LED s 2 and 3 will light up Within 10 sec press P button on the device and hold until the network status LED lights up see device programming manual Controller signals device correct removing from the network and group by lighting of LEDs 1 and 4 Controller signals incorrect removing by blinking of LEDs 2 and 3 and the procedure should be performed again from point 1 Note With the use of EXCLUDE function it is A also possible to remove reset devices assigned to other networks Restoring controller to factory settings Resetting the controller will cause removing of all devices from its memory and the change of unique HomelD network address for a new one Removing devices from the controller will not cause reset of devices themselves If the user wants to add them once again to the Z Wave network controller s memory it is necessary to perform EXC
10. group 7 8 channel 4 group 9 10 channel 5 Programming button IN EX under back cover of the remote control Control modes Basic press button of movement or v within 0 5 sec in order to cause the device to move and press Hin order to stop the device Multilevel press button a or v and hold until the device reaches desired position and then release the button Z FAKRO AAA15V y y General information Operation of FAKRO products is based on radio communication protocol Z Wave To enable the controller to operate FAKRO Z Wave electrical accessories it is necessary to configure them appropriately into one Z Wave radio network For this purpose there are used appropriate commands performed on the controller Each network has its address HomelD and each device in the network has its number NodelD All devices in the Z Wave network are divided into operating devices controllers and devices controlled e g servo motors Single controlled device can operate only within one network single HomelD and one network can include only one basic PRIMARY controller overriding In order to add second controller it must be set as SECONDARY subordinate When configuring devices to operation in the network address HomelID is assign to them and Node ID appropriate in order fig 1 Basic functions of the Z Wave syste
11. ithin 10 sec press P button on the device see device programming manual Controller signals correct adding to group by lighting of LEDs 2 3 4 Controller signals incorrect adding by blinking of LEDs 1 2 3 and the procedure should be performed again from point 2 Adding another controller to the Z Wave network LEARN MODE Function is used for copying information about devices from basic controller PRIMARY to additional and making it a SECONDARY controller After performing LEARN MODE on the controller it is also necessary to assign device to buttons of movement with the use of ASSOCIATE function It is better to perform LEARN MODE function after adding all devices to basic controller or after modification of the network Press once IN EX button on basic remote control LEDs 1 and 4 will light up Within 10 sec press three times IN EX button on additional remote control until lighting of LEDs 1 and 3 Within 10 sec on basic remote control LEDs 2 and 3 will light up and on additional 2 and 4 will light up If the sequence does not occur perform the procedure from the beginning Note With the use of an additional controller A SECONDARY it is not possible to add device to the network INCLUDE and remove device from the network EXCLUDE However it is possible to perform ASSOCIATE and DELETE functions PRIMARY and SECONDARY function of the controll
12. m Include adding device to the network Associate adding device to buttons of movement group Delete removing device from buttons of movement group Exclude removing device from the network Learn Mode adding another controller Default restoring controller to factory settings To simplify configuration some of above procedures were joined what will be explained in the chapter concerning programming Sample scheme of the Z Wave network Lo Z Wave u HomelD AAA Secondary M ZWG3 rt Exclude Primary ZWP10 ARZ Z Wave gt Delete NodelD 003 i Include ARZ Z Wave i i HomelDi Assciate eee Learn Mode AAA i i i i i NodelD ka i 002 f Primary i Put batteries in the controller Screw holder firmly to the Put the washer on the wall with the use of anchor holder pins Check whether the remote control is firmly located in magnetic washer Prepare device which is to be operated see Product User Manual Make sure that the device is appropriately installed and plugged in to power supply Make sure that you have physical access to programming button and device manual operating button Make sure that the device operates appropriately by pressing manual operating button Make sure that the network status LED on the device which is to be added to controller lights up If the network
13. on of devices within one Z Wave network that one controlled device launch another device not assigned to controller s buttons of movement An example is launching of one servo motor with the use of another servo motor equipped with a rain sensor On PRIMARY controller within 1 sec press once IN EX button and once SELECT button LEDs 1 and 2 will light up Within 10 sec press P button on the device which is to be controlled until LEDs on the controller change into 3 and 4 Within 60 sec press P button on the device which is to be operated see device manual until LEDs on the controller change into 1 2 3 4 If a given sequence of LEDs does not occur it is necessary to perform procedure again Copying group of devices COPY GROUP This function allows for copying group of devices from PRIMARY controller to SECONDARY controller and conversely within one network Choose channel and within 1 5 sec press IN EX button 3 time on the controller no I LEDs 1 and 3 will light up Within 10 sec press STOP button the group copied until LEDs change to 3 4 Within 10 sec choose channel and perform ASSOCIATE function on the target controller no Il by pressing IN EX and STOP button of a group to which device is to be copied LEDs change to 2 3 4 and on the controller no to 1 2 3 4 If a given sequence of LEDs does not oc
14. status LED does not emit light it means that the device is not plugged in to power supply manual operation does not work or it has already been assigned to the same or other controller f Note In devices powered by photovoltaic panel AMZ Z Wave Solar awning blind ARZ Z Wave Solar roller shutter the network status LED should light up for 5 sec after pressing P button what means readiness to assign device to the network Adding device to the controller and buttons of movement If device has not been purchased with the controller in a set it should be programmed If the network is configured again it is necessary to reset the controller to factory settings DEFAULT function and then follow below presented steps in appropriate time intervals Choose one of 5 channels on which the device is to be assigned by pressing SELECT button Press IN EX button on the back of the controller If LEDs 1 and 4 light up then press one of movement buttons of a given group until LEDs change for 1 2 3 Within 10 sec press P button on the device until the network status LED is off see device programming manual Controller signals device correct adding by lighting of LEDs 2 3 4 Controller signals device incorrect adding by blinking of LEDs 1 2 3 and the procedure should be performed again from point 2 After the above steps to ensure proper operation of the device wait 10sec Now controller is