1. IP 40 DIN rail mount 550 000 h MIL HDBK 217F 40 70 C 29 165 F temperature hardened 50 85 C 40 176 F 95 non condensing IEC60068 2 6 sine IEC60068 2 27 BS2011 p2 1 EN61000 6 1 Immunity residential environments EN61000 6 2 Immunity industrial environments EN61000 6 4 Emission industrial environments EN55022 A1 Emission IT equipment EN55024 Immunity IT equipment FCC part 15 class A EN50121 4 Railway signalling and telecommunications apparatus 1EC62236 4 Railway signalling and telecommunications apparatus UL IEC EN 60950 1 IT equipment DNV standard for certification no 2 4 To be ordered separately please check available models from MWF and MWG series f your existing CAT5 cable was installed before 1995 make sure that it has been fully tested for use with 1000Base TX Block d lag ram Example for 10 port model MES110 managed ethernet switch Switching Fabric Network Video Recorder MES106 110 user manual 8x 10 100Base TX Ports Manegement System Ete 2x SFP Ethernet Ports 100 1000Base X Ethernet Network 13 Safety 14 FCC Part 15 105 Notice Corrosive environment Notice Safety warning Do not open connected unit Hazardous voltage may occur within this unit when connected to power supply Note that this unit can be connected to two different power sources When this unit is operated at an ambient
2. easily use a web browser to configure the unit Within the web you can configure most of the available functions For advanced network settings and more diagnostic information please use the CLI Detailed documentation is available upon request Factory default IP address 10 9 96 30 Netmask 255 255 255 0 Gateway 10 9 96 1 Note If you are not sure about the subnet consult your network administrator Configure the unit via Web browser The unit can easily be configured via a Web browser Open the link http 10 9 96 30 in your web browser and you will be prompted with a Login screen where the default settings for Username and Password are Username admin Password teleste Once you have logged in you can use the extensive integrated help function describing all configuration options Two common task when configuring a new switch is to assign appropriate IP settings and to change the password of the admin account The password can be up to 64 characters long and should consist of printable ASCII characters ASCII 33 126 Space is not a valid pass word character Note Version of IP Config tool must be 10 3 0 or higher MES106 110 user manual Connections Ethernet switch mechanical connections Power connector 4 pin detachable screw terminal Indicator leds 4 8 x 10 100Base TX local ports RJ 45 female l O connector 4 pin detachable screw terminal IO 2 x 100 1000Base TX or 2 x
3. FRNT RsTP LF OOL Side view Wy UIN ululG 7 Xe N Front view MES106 110 user manual 12 Tech n ical S pecifications Typical values unless otherwise stated Up link ports SFP Number of ports Standard Connector types RJ 45 simplex LC duplex LC Local ports Number of ports Standard Connector type Protocols 802 3 802 3u 802 3ab 802 3z 802 1q 802 1d 802 1w 802 1p 802 3p 802 3x IGMP FRNT vO SNMP DHCP Management WebUI SNMP 2 pcs 100Base TX 100Base FX 1000Base TX 1000Base FX electrical optical optical 8 pcs 4 pcs 10 100Base TX RJ 45 10Base T 100Base TX FX 1000Base T 1000Base SX LX VLAN STP RSTP QoS QoS flow control version 1 2 amp 3 redundant ring version 2c CATS CAT5e CAT6 MMF amp SMF CATS CAT5e CAT6 MMF amp SMF MES110 MES106 electrical layer 2 layer 3 IP ToS proprietary protocol IP address adquisition local via ethernet port amp remote via network remote via network General Supply voltage Power consumption PSU connector type Dimensions H x W x D Weight Degree of protection Housing MTBF Operating temperature Storage temperature Humidity Vibration Shock Damp heat EMC compatibility Safety Marine Notes 19 60 V DC nominal 24 V DC 6W at 24V DC 4 pin removable screw terminal 100 x 52 x 101 mm 3 93 x 2 04 x 3 97 0 7 kg 1 54 Ibs
4. Type tests and environmental conditions inno ttti theta ee A 16 Legal AOC AN Atl OMS IM TET ILU OI LI LLLI 20 Safety warning Before installation Read this manual completely and gather all information on the unit Make sure that you understand it fully Check that your application does not exceed the safe operating specifications for this unit This unit should only be installed by qualified personnel This unit should be built in to an apparatus cabinet or similar where access is restricted to service personnel only The power supply wiring must be sufficiently fused and if necessary it must be possible to disconnect manually from the power supply Ensure compliance to national installation regulations This unit uses convection cooling To avoid obstructing the airflow around the unit follow the spacing recommendations see Cooling section Before mounting using or removing this unit Prevent access to hazardous voltage by disconnecting the unit from power supply Warning Do not open connected unit Hazardous voltage may occur within this unit when connected to power supply Before powering up a protective earthing conductor must be connected to the protective earthing terminal and have a cross sectional area of at least 1 5 mm Note that this unit can be connected to two different power sources When this unit is operated at an ambient temperature above 55 C 131 F the External Surface of Equipment may
5. V m 80 800 MHz 20 V m 800 1000 MHz i 10 V m 1400 2100 MHz Radiated RF t EN 61000 4 3 Encl adiate immunity nclosure 5 Vim 2100 2500 MHz 1 V m 2500 2700 MHz 1 kHz sine 80 AM Power port 10 V 80 AM 1 kHz 0 15 80 MHz Conducted RF immunity EN 61000 4 6 Signal ports 10 V 80 AM 1 kHz 0 15 80 MHz Earth port 10 V 80 AM 1 kHz 0 15 80 MHz EN 55022 Class A Radiated RF emission Enclosure FCC Part 15 Class A Power port Class B Conducted RF emission EN 55022 Signal ports Class B Power port to all other ports 1 5 kVrms 50 Hz 1 min Dielectric strength EN 60950 1 Signal ports to all other ports 1 5 kVrms 50 Hz 1 min 16 MES106 110 user manual Environmental Basic standard Description Test levels Operating 40 to 70 C 40 to 158 F Temperatures Storage and transport 50 to 85 C 58 to 185 F Operating 5 to 95 relative humidity Humidity Storage and transport 5 to 95 relative humidity Altitude Operating 2000 m 70 kPa Service life Operating 10 year Reliability prediction MTBF MIL HDBK 217F Operating 587 000 h 3 13 2 Hz 1mm 13 2 100 Hz 0 7 g IEC 60068 2 6 Vibrati O ti ndn sine Peg 5 5 30 Hz 1 5g 30 50 Hz 0 42 mm 50 500 Hz 4 2 g 30 g 11 ms Shock IEC 60068 2 27 O ti oc perating 100 g 6 ms Bump IEC 60068 2 27 Operating 10 g 11 ms Packaging Bas
6. exceed Touch Temperature Limit according to EN IEC UL 60950 1 To reduce the risk of fire use only No 26 AWG or larger telecommunication line cord Class 1 Laser Product Do not look directly into fibre optical fibre port or any connected fibre although this unit is designed to meet the Class 1 Laser regulations MES106 110 managed Ethernet switch introduction 4 8 x 10 100Base TX IEEE 802 3 ports and 2 x 100 1000Base FX or 2 x 100 1000Base TX uplink ports for SFP transceivers Welcome and thank you for purchasing Teleste s CFO Products wes Genere Local pos E E hrs ports 10 100 sE 100 1000 TX FX The Teleste MES106 110 are an Industrial switches made for harsh enviroments The switches can be used in ether 100 Mbit or Gigabit networks due to a multi rate SFP solution MES110 In addition to standard STP and RSTP protocols the MES switch Local s E EF E ports provides an unique FRNT Fast Recovery of Network Topology tech HS HE 100 1000 TX FX mology is the fastest protocol on the market to re configure a network in the event of any link or hardware failure That is why MES is used in safety critical applications such as tunnels traffic signal control and railway systems Installations in harsh environments and places with heavy electrical interference require the use of a reliable media MES provides a num ber of solutions using fibre optic transceivers Multi or singlemode transceivers can be used to build point to point or
7. up MES106 110 user manual 2 fibre version 1 fibre version TX M Rx SFP optical transceiver module Optical connector is type LC PC Optical connection meets class 1M laser safety requirements of IEC 60825 1 2001 and US department of health services 21 CFR 1040 10 and 1040 11 1990 when operated within the specified temperature power supply and duty cycle ranges MES106 110 user manual Uplink port connections For uplink network connections the MES switches has up to two 2 100 1000Base TX or two 2 100 1000Base FX SFP transceivers Ethernet SFP pluggable connections FX or TX Electrical specification IEEE std 802 3 2005 Edition Data rate 100 Mbit s or 1000 Mbit s transceivers supported Duplex Full or Auto depending on transceiver Transmission range Depending on tranceiver Conbetilon SFP slot holding fibre transceiver or copper transceiver Number of ports 10r2 The optical interface is a small form factor pluggable SFP see picture beside The optics is hot swappable Optical cable connector in use is type LC PC The optical operation depends on the type of selected SFP transceiver module This information is marked to the model s type sticker which is located on the side of the unit When installing the fibre optic cable do not exceed the minimum bending radius when connecting cable to the system Note For correct
8. 06 110 user manual eX USB E MES106 110 user manual USB connection On MES units equipped with a USB port a USB memory stick can be used for automatic backup and restore The intended application for the auto backup function is to simplify unit replacement in case of unit failure Once activated it works seamlessly If a stick already is prepared nothing else is needed If a unit fails you simply replace it moving the USB stick to the replacement unit Which must be of same mark and model At first boot the replacement unit automatically restores all necessary files from the faulty unit Note The auto backup and restore function only handles con figuration It does not handle backup restore of firmware images You must not only ensure that your replacement unit is of the same model as the original unit It should also have same oper atig system firmware feature version loaded as the original unit Position Direction Description No 1 Out VBUS No 2 In Out D No 3 In Out D No 4 Out GND Shield In Out Connected to protective earth USB Electrical specification USB 2 0 host interface Data rate Up to 12 Mbit s full speed mode Circuit type SELV Maximum supply current 500 mA Connection USB receptacle connector type A Installation DIN rail mount The DIN rail attachment on the back of the MES device is used to snap into the 35 mm DIN rail Integrates B
9. 100 1000Base FX uplink ports for IO e SFP transceivers 6 Power indicator led 7 USB 2 0 port only at MES106 O AUN 8 I O connector 4 pin detachable screw terminal 9 Console port 10 Serial management cable CIC507 x lt a wW 7 lt a e S Ss DRO be o GOHI e e OE o MA MES106 110 bottom view 10 100 BASE TX MES106 Front panel MES106 110 user manual 3 Power supply connection MES supports redundant power connection The positive inputs are DC1 and DC2 the negative input for both supplies are COM Connect the primary voltage e g 24V DC to the DC1 pin and return A UOUN Power connector 4 pin detachable screw terminal to one of the COM pins on the power input Pin number Symbol Description 1 DC1 Supply voltage input DC1 2 DC2 Supply voltage input DC2 3 COM Common 4 COM Common Power specifications Operating voltage Rated 24 to 48 VDC Operating 19 to 60 VDC Rated current 240 mA 24 VDC 120 mA 48 VDC Rated frequency DC Inrush current 12t 22 7107 As 48 VDC Startup current 2 x Rated current Polarity Reverse polarity protected Redundant power input Yes Isolation to All other Connection Detachable screw terminal Connector size 0 2 2 5 mm2 AWG 24 12 Shielded cable Not required External supply current capability for proper start
10. IN back VIGN Snap on mounting with integrated DIN clip that the DIN rail is connected Pius eu eine el to ground Removing MES with integrated DIN clip Press down the support at the back of the unit using a screwdriver 10 MES106 110 user manual Optional mounting kit item code CIKOO7 MES106 110 user manual Cooling MES unit uses convection cooling To avoid obstructing the airflow around the unit use the following spacing rules Minimum spacing 25 mm 1 0 inch above below and 10 mm 0 4 inches left right the unit Spacing is recommended for the use of unit in full operating temperature range and service life 10 100 BASE TX Optional wall mount For wall mount please use optional accessory kit MACOOT The mounting kit has a DIN rail to host a MES switch MACO07 is mounted to the wall by means of 4 fixing screws 40 20 Mmi 94 5 0 7 5 us amp P 40 li 103 H 125 5 103 C5 0 1 wi n 10 Front view Side view Back view 11 Mechanical drawing Example for MES110 same information applies respectively to MES106 unit 1 Ty 1 L2 TAL ANNAN rainy 96 1 MLDZNIDZAVMLML 7 1 LY ECL E71 AID N U G Jj S Q0 ET a A LF Ve o e e e o 52 1 XL ASVd 001 01
11. INGICALONS a Ai dincsctssiewsiels tnae a a E a aa A a A aa buns adiduratastueusevuaadtelads JA a Gites smennenss tandete 7 Digtal VO Conte ction ccr ere Pare Ru cad EAS 7 USB CONNECCION 1252 P 9 jecur mE EUREEN 10 DIN Fall WOU Ge ienee aE tans A e nals E ta wdsaalenbasaioadh casei tewssadldtts e a aa 10 DIN Heirsumecbe D n 10 Gre Om 11 Optional wall tmo nro XR et um tn xeu dea I x Ranemusalted mua dus am esl uu S RO TUUS 11 Mechanical drawing etin En ein LIRE INFR at insicee elsnunctuesdeaveteesecivsdueceentavsoeetensvaddesdissadeeces 12 Technical SpecifICatiOlns coco rene rax Rm Eae a aee ERN RENE E Du AEE a AEE aE Eu E E TENE AEEA E EEEE aaas 13 Block diagram ere nere eessaadcexncsacuce cuussastecpdedasocceceessucesceds sudse4 evasacceentegades LIE E eI LEE 13 ONCE Y oss E P 14 SIR e m 14 MEBcujeer EET 14 Agency approvals and standards compliance ssssssssssssssssssseee e eene erremrernn nennen 14 Factory default settings tedio MI rex sete leads Mns dte Ncc lit scc eerte leere E P EA UE 15 Factory default oi MES106 and MES 110 adero dca o edd e ee eee a e tid 15
12. TELESTE User manual MES106 110 Managed ethernet switch The Teleste MES106 110 is a layer 2 industrial Ethernet switches designed with 6 8 Fast Ethernet ports and 2 Gigabit or 100Mbit uplink ports to ensure high bandwidth uplink connection for large scale surveillance in video networks 100 1000 i ul ui Q Q lt E E Ss S Video Networks MES106 110 user manual 59300511 rev001 Contents MES106 110 managed Ethernet switch introduction esee nnne nnne nnn nennen nnns 1 General sere 1 lr C EE 1 cunc 2 IUe SratD oj se E a E EENE AT 2 Configure the unit Via WoD DrOWSEN ttc rrt ti doce E cu pun c R e cte d 2 Connections aseissa aae eae ea a a EE a EEEa aaea ea Ea aaa Aaa ea aa aaa EE aaa NaNe aE Ekaa auaa in aaa 3 Ethernet switch mechanical connectloris eco entera tente te ana eret na ee dee a A AE Aa GAS 3 Power supply ConnectlOh iier te orte E MEER ERE RM TNT NA tA TUS ERE AA EA ERRIREN ER aa 4 Uplink port connections 2 65 toe eren b n ne eg ep RR eae RE es Ran ERE E a eain 5 SEP TrarnscelVets eite ER a NR SAX ud u NN XR Renan tua a en kN ERN M Cen KE aa a E Era 5 Local port COMME CHONG cce iter tes ere rd e hee en rad ex phil gun ke Medii estie date RP Lb d a usd e ddr Ae RR d 6 Console port connectlori iie oe oir ren ERES ERR RRUEER RENRKCAENENENNMA AES SRERUREEE RR ERE EXER SR UMEN RERK TRA E a aaa EA 6 Eed
13. hoice to go ahead with the factory reset or to skip factory reset and boot as normal Go ahead with factory reset Acknowledge that you wish to conduct the factory reset by unplug ging the Ethernet cables The ON LED will stop flashing This initiates the factory reset process and the unit will restart with factory default settings When the switch has booted up the ON LED will show a green light and is now ready to use Skip the factory reset MES106 110 user manual To skip the factory reset process just wait for approximately 30 seconds after the ON LED starts flashing RED without unplugging the Ethernet cables The switch will conduct a normal boot with the existing settings Note Do not power off the unit while the factory reset process is in progress Type tests and environmental conditions Environmental phenomena Basic standard Description Test levels Contact 6 kV ESD EN 61000 4 2 Encl TRIS Air 8 kV Power port 2 kV Fast transients EN 61000 4 4 Signal ports 2 kV Earth port 1 kV L E 0 5 kV 12 Q 9 uF L L 0 5 kV 2 Q 18 uF Pone Don L E 2 kV 42 Q 0 5 uF P L L 2 kV 42 Q 0 5 uF Surge EN 61000 4 5 L E 2 kV 12 O 9 UF L L 1 kV 12 Q 9 uF Signal ports spud dus ee L E 2 kV 420 0 5 uF P f Hale eee EN 61000 4 8 Enclosure 300 A m 0 16 7 50 Hz magnetic field Pulsed magnetic field EN 61000 4 9 Enclosure 300 A m 10
14. ic standard Description Test levels Enclosure EN 60950 1 Zinc Fire enclosure Dimension W x Hx D 52 5 x 100 x 101 mm With connectors 52 5 x 119 x 101 mm Weight 0 7 kg Degree of protection EN 60529 Enclosure IP 40 Cooling Convection Refer to Safety section Might require Ethernet cables to be fastened close to the unit MES106 110 user manual 17 TELESTE Legal declarations Copyright 2013 Teleste Corporation All rights reserved TELESTE is a registered trademark of Teleste Corporation Other product and service marks are property of their respective owners This document is protected by copyright laws Unauthorized distribution or reproduction of this document is strictly prohibited Teleste reserves the right to make changes to any of the products described in this document without notice and all specifications are subject to change without notice Current product specifications are stated in the latest versions of detailed product specifications To the maximum extent permitted by applicable law under no circumstances shall Teleste be responsible for any loss of data or income or any special incidental consequential or indirect damages howsoever caused The contents of this document are provided as is Except as required by applicable law no warranties of any kind either express or implied including but not limited to the implied warranties of merchantability and fitness for a par
15. ion Yellow Port alarm and no link Or if FRNT or Up link port s leds indicator lights RSTP mode port is blocked Digital I O connection The Status output is a potential free opto isolated normally closed solid state relay This can be configured to monitor various alarm events 1 within the MES unit 2 An external load in series with an external voltage source is required for proper functionality 3 For voltage current ratings see Technical specifications 4 Pin number Symbol Direction Description 1 Status Output Alarm relay status contact I O connector 4 pin detachable screw terminal 2 Status Output Alarm relay status contact 3 Digital in Input Digital in 4 Digital in Input Digital in MES106 110 user manual 7 MES110 External load The Digital IN is an opto isolated digital input which can be used to monitor external events For voltage current ratings see Technical specifications 1 0 Relay output Maximum voltage current 60 VDC 80 mA Contact resistance Max 30 Q Isolation to All other Connection Detachable screw terminal Connector size 0 2 2 5 mm2 AWG 24 12 I O Digital input Maximum voltage load current 60 VDC 2mA Logic one gt 12V Voltage levels 9 Logic zero lt 1V Isolation to All other Connection Detachable screw terminal Connector size 0 2 2 5 mm2 AWG 24 12 MES1
16. kely to cause harmful interference in which case the user will be required to correct the interference at his own expense This product has been successfully tested in a corrosion test according to IEC 60068 2 60 method 3 This means that the product meets the requirements to be placed in an environment classified as SA S71 04 class G3 Note If the product is placed in a corrosive environment it is important that all un used connector sockets are protected with a suitable plug in order to avoid corrosion attacks on the gold plated pins in connectors MES106 110 user manual Factory default settings Factory default on MES106 and MES110 It is possible to set the unit to factory default settings by using two straight standard Ethernet RJ 45 cables 1 Power off the switch and disconnect all Ethernet cables copper and fibre Connect one Ethernet cable between Ethernet ports 3 and 6 and the other between Ethernet ports 4 and 5 MES106 Connect one Ethernet cable between Ethernet ports 3 and 10 and the other between Ethernet ports 6 and 7 MES110 The ports need to be connected directly by an Ethernet cable i e not via a hub or switch Use a straight cable not a cross over cable when connecting the ports Power on the unit Wait for the unit to start up Control that the ON LED is flashing red The ON LED flashing indicates that the unit is now ready to be reset to factory default You now have the c
17. optical operation and to ensure quality connections between fiber optic devices it is important that every fiber connector be inspected and cleaned prior to mating Connectors should always be cleaned with professional cleaning equipment and accessories for fibre optics The optical connectors on the equipment should always be protected with dustcaps when there is no fibre inserted Any contamination in the fibre connection can cause failure of the component or failure of the whole system Even microscopic dust particles can cause a variety of problems for optical connections A particle that partially or completely blocks the core generates strong back reflections which can cause instability in the laser system Dust particles trapped between two fibre faces can scratch the glass surfaces Even if a particle is only situated on the cladding or the edge of the endface it can cause an air gap or misalignment between the fibre cores which significantly degrades the optical signal SFP Transceivers Supported transceivers Only Teleste MWF and MWG series SFP models are compatible with the switch Other vendor models are usable but will create a notification Temperature specifications are also depending on the used transeivers Note To comply with UL60950 1 only UL recognized SFP transceivers should be used Deviations With copper transceiver 1100 0148 the specified operating temperature on MES is 0 to 50 C 32 to 122 F FRNT reconfig
18. redundant ring networks with ranges up to 120 km between each switch Our BIDI transceiver which transmits and receives data on a single fibre can be used in applications where the number of fibre cores are limited Real time properties are implemented in the switch in order to achieve determinism for real time critical applications MES supports QoS Qual ity of Service with four priority queues and strict priority scheduling as well as HoL Head of Line Blocking Prevention All to assure that the data network is deterministic Advanced switch operation for multicast video Compact ethernet switch design Advanced Layer 2 functionality Low power consumption Dual power input wide voltage range Highly configurable fault I O contact Robust metal DIN rail housing 550 000 hours MTBF to MIL HDBK 217K Operational temperature 40 to 70 C passive cooling Industrial EMC shock and vibration testing Fast reconnect for multicast protocols MES106 110 user manual 1 Getting started This product runs a specific operating system which provides several management tools that can be used for configuration of the unit PConfig tool This is a custom IP tool used for discovery of network switches Web Configuration of the unit using the web browser CLI Configuration of the unit via the Command Line Interface Username admin Password teleste If the computer is located in the same subnet as the switch you can
19. rt connection The console port 9 can be used to connect to the CLI Command line interface 1 Connect the serial diagnostic cable to the console port 2 Connect cable to your computer USB port 3 Use a terminal emulator and connect with correct speed and format 115200 8N1 to the assigned port NOTE For more information about the CLI see the management guide Console connection MES106 110 bottom view Electrical specification TTL level Data rate 115 2 kbit s Data format 8 data bits no parity 1 stop bit no flow control Circuit type SELV Connection 2 5 mm jack use only serial i management cable CIC507 6 MES106 110 user manua Led indicators Led Colour Description No light Power OFF ON Green Power ON E Red Alarm condition Blinking Switch is selected in the IPconfig tool No light Power OFF DC1 Green Power ON and OK on DC1 Red Power failure on DC1 No light Power OFF DC2 Green Power ON and OK on DC2 Red Power failure on DC2 No light FRNT disabled Green FRNT OK FRNT Red FRNT error Blinking Unit configured as FRNT Focal point No light RSTP disabled RSTP Green RSTP enabled Blinking Unit elected as RSTP STP root switch No light VPN disabled USR1 Green At least one VPN tunnel up and OK Red All VPN tunnels down No light No Link Green Link established 1to 10 Blinking green Data traffic indicat
20. temperature above 55 C 131 F the External Surface of Equipment may exceed Touch Tem perature Limit according to EN IEC UL 60950 1 To reduce the risk of fire use only No 26 AWG or larger telecommuni cation line cord Maintenence No maintenance is required as long as the unit is used as intended within the specified conditions Agency approvals and standards compliance Type Approval Compliance EN 61000 6 1 Immunity residential environments EN 61000 6 2 Immunity industrial environments EN 61000 6 4 Emission industrial environments EN 55022 A1 Emission IT equipment EN 55024 Immunity IT equipment FCC part 15 Class A EN 50121 4 Railway signalling and telecommunications apparatus IEC 62236 4 Railway signalling and telecommunications apparatus Safety UL IEC EN 60950 1 IT equipment Marine DNV Standard for Certification no 2 4 This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is li
21. ticular purpose are made in relation to the accuracy reliability or contents of this document Teleste reserves the right to revise this document or withdraw it at any time without notice CC 9 Teleste Corporation P O Box 323 FI 20101 Turku Street address Seponkatu 1 20660 Littoinen FINLAND www teleste com
22. uration times can not be guaranteed with copper transceivers Local port connections A standard MES106 switch comes with four 4 10 100Base TX local ports CAT5 A standard MES110 switch comes with eight 8 10 100Base TX local ports CAT5 All local ports support full wire speed This equates to 100 Mbps full duplex on every port 100 Mbps in each direction on all ports equals 200 Mbps per port 8 1 RJ 45 female Ethernet connector Ethernet TX connections T Signal Signal Pin MDI MDIX Electrical specification IEEE std 802 3 2005 Edition 1 Tx Rx Data rate 10 Mbit s 100 Mbit s manual or auto 2 TX Rx Duplex Full or half manual or auto 3 Rx Tew Circuit type TNV 1 4 Transmission range Up to 150 m with CAT5e cable or better 5 E Isolation to All other 6 Rx TX 7 N Connection RJ 45 auto MDI MDI X 8 Not required except when installed in Railway Shielded cable applications as signalling and telecommunications Pinout for RJ 45 Ethernet connector apparatus and located close to rails Conductive housing Yes Number of ports 4 MES106 or 8 MES110 Refer to Safety section To minimise the risk of interference a shielded cable is recommended when the cable is located inside 3 m boundary or the cable is longer than 30 m and inside 10 m boundary to the rails and connected to this port Console po