Home

User manual ArcControl 1 - AV

image

Contents

1. If you use single colour LED fittings set ArcPower SmartWhite driver DMX address at 5 Mal po 3 2 Set RGB or RGBW mode along according to used LED fittings See DMX chart of respective ArcPower driver Usually it is mode 1 or 2 AP driver menu path 5PE 4d P Vel 2 2 31 Ee Pi 3 Set DMX mode in the menu Protocol AP driver menu path SPE Prt dih Rss ArcPower driver ArcControl 1 Note GND terminals interconnected on PCB printed circuit board 2 4 Multiple installation with the ArcPower drivers If you need to control the ArcPower driver s from several places simultaneously you can use more ArcControl s1 connected in parallel In this case the following changes has to be made 1 ArcCotrol 1 two pads marked J1 must be E c2 2 interconnected SV2 13 0113 1 Sit 2 ArcPower driver Set dynet mode in T the menu Protocol AP driver menu path SPE Prt d9n A Interconnect the pads 8 7 6 2 if multi fixture operation DMX input of is reguired ArcPower driver Example of wiring E a sv2 SV2 Ga E is GND GND DO svi Mim tea A les Fea a 287 6 DMX input of ArcPower driver ArcControl 1 3 Operation The ArcControl 1 u
2. ANOLIS ArcControl 1 USER MANUAL Version 1 1 ArcControl 1 Table of contests a o AA a lohsne dua dageceedsdtecicascsedde a ea A ESSEED ED EME AES MEE aa En 2 1 M UNEING seedri vatti seta taa aal it aate a ait O DELIMITAN E EE E E ketaste aetud paku a is ae EE eS 2 3 Single installation with the ArcPower drivers cccccononooooncnncnnonononnnnncnnnnnnnnononnnnnnnnnnnonenonnnnncanananos 2 4 Multiple installation with the ArcPower drivers cccccssccccccecssssseceeesecesseseeaeseeeceecessessasaeeeeeeesees EL sl ii AA a eee 4 Technical Specifications sissien st ide LASU daa ArcControl 1 1 Introduction The ArcControl 1 is the perfect solution to provide the user control of installed Anolis LED light fittings This slim line LED control panel allows to dim LED light fixtures set desired colours and run built in programs The ArcControl 1 should be installed with Anolis ArcPower driver s 2 Installation 2 1 Mounting The ArcControl 1 control panel is designed for wall mounting into KU 68 universal box To install the ArcControl 1 1 Prepare the wall by drilling the necessary holes fitting the KU 68 universal box and cables 2 Attach the DMX output and power wires to the terminal blocks being careful to observe the correct polarity 3 Screw the metal frame plastic frame to the KU 68 universal box 4 Snap the ArcSource 1 panel to the plastic frame OO Ci box KU 6 2 2 Wi
3. ring Figure below shows the DMX output terminals P1 on the unit and two supply terminals SV1 SV2 The input SV1 or SV2 has to be connected to a 12 V DC supply ArcControl 1 SV2 hizv 2 DC GNI Svi 12 2 DC GN 6 gi Signal signai Signal Gi P1 Connectors DMX and supply wires are connected to the self locking terminals PHOENIX located on the PCB of the ArcControl 1 Insert each wire directly to the circular hole of the terminal and check its fixation To release the wire insert appropriate tool narrow flat tip screwdriver to small rectangle terminal hole and the wire will be released 2 3 Single installation with the ArcPower drivers The ArcPower drivers offer 12 V at DMX input connector pin 2 which can be used for supply of the ArcControl 1 unit RJ45 socket for DMX IN Front view of the socket Pin 1 Not connected Pin 5 5V Pin 2 12V Pin 6 Data Pin 3 Not connected Pin 7 Data Pin 4 Not connected Pin 8 GND Owing to this feature you can use only one cable for DMX connection and power supply Use a suitable cable with 2 twisted pair of conductors and connect pins 2 6 7 8 of DMX input of the ArcPower driver A ArcPower driver setting 1 Set ArcPower driver to DMX address 1 If you use two or more drivers set all DMX addresses at 1 pe a al Note
4. ses 12 control buttons for setting desired colour dimmer level and program selection Description of function of each button ArcControl 1 ON ArcControl 1 OFF RED GREEN BLUE CYAN Switches to desired colour You Turns on desired colour 6 can select from two tones of each MAG YEL colour by pressing button 0 O repeatedly Note Adjusted dimmer level is kept Note Adjusted dimmer level is kept Switches to white colour By Turns on white colour pressing the button repeatedly you select betwen colour temperature of 3200K 5600K and 8000K Note Dimmer level maximum Note Dimmer level maximum Dimmer up Switches to last state Switches to last state Dimmer down Note Dimmer minimum both buttons Program running slow colour Program running slow colour changing Red gt Green gt Blue changing Red gt Green gt Blue Program running fast colour Program running fast colour changing Red gt Blue gt Green changing Red gt Blue gt Green Switches OFF the ArcControl 1 Switches ON the ArcControl 1 to the last colour Function is available in Single installation only 4 Technical Specifications Input voltage 12VDC Input current 15mA ArcControl 1 Compatible drivers ArcPower 36 ArcPower 72 ArcPower 144 ArcPower 360 and their K2 variants Dimensions Included items 1 x ArcControl 1 ArcControl 1 184 80 5 Uni
5. versal box KU 68 72 O 43 1 x Universal box KU 68 accessories 1 x User manual Specifications are subject to change without notice May 29 2012 Anolis

Download Pdf Manuals

image

Related Search

Related Contents

Kontakt - Sivilingeniør JF Knudtzen AS    RDI計量ユニット  Sección 11 Transmisión  形式 MD3D- V  BEDIENUNGSANLEITUNG  Electro-Voice US637BA User's Manual    sunsys - Socomec  取扱説明書 - サンテスト  

Copyright © All rights reserved.
Failed to retrieve file