1. Select input pin Type a Year type This input enables the specific year date or between years and dates to be selected Modify pin configuration SS ee v 72 57 71 7 P gt sss P MN Base information Subnet ID Logic number Modify relation of input pins wl ESH HH MM SS Invalid Designate Year Designate Year 0 Date type This input allows the date with and month to be specified Options At date point Select or designate a specific date for example June 44 Date period Select the date or time interval for example Oct 7 Nov 30 Every month Select this to apply the settings to the whole year Logic timer User Manual User M H D L a Luc c0 Logic number Modify relation of input pins Eed HH MM SS Modify input pin configuration Select input pin cou Time Type Type Invalid Specific Time H M Select Mode Time Time At Point o c Week type Select a specific day of the week or between weekdays from one specific day to another e g Monday Friday d Time type Select a particular time of day or before and after a specific time specific time select a particular time you can also set the specific time as sunrise or sunset you need to set the time for sunrise and suns
2. Method for Prayer Timers G Muslim World League O Egyptian General Authority of Survey University of Islamic Sciences Karachi O Umm Al Qura O North America Twilight Angle in degress Fajr Ishe 10 5 10 5 O Twilight Angle and Time Difference Fajr hio E 100 Taz 4 3 4 Summer time settings Due to some countries using summer time settings the module is programmed to take Logic timer User Manual User M H D L Mpa alen into account the country it is located in to provide an accurate time An end user needs only to input their region to ensure local time is implemented Summer Time Month Day of week Time Rule for Start March Friday 2nd 1 00 Rule for End October Sunday se The last 1 00 ve Show standards Europe EEE na AP Europe Rule for Daylight Savings Sta New Zealand Rule for Daylight Savings End 01 00 UTC on the last Sunday in October Save 5 Applications 5 1 Application 1 Irrigation scheduling Requirement If for instance a user wished to turn on their irrigation system at 9 am every Sunday for 40 minutes they would follow the below example Note The end user is able to disable or enable the logic schedule by simply pressing a button The relay module via a relay channel controls the water valve Configuration Logic module No 1 tumON Irrigation Delay S 0 AND Sunday At Time 09 00 Logic 1 There are three conditions 1 wee
3. Delayinn ss la Object no 21 Mechanic switch N A OFF toggleswtch 00 Logic timer User Manual User M H D L ben 6 NOTES Logic timer User Manual
4. functions that require a date and time signal Logic timer Device 6 14 SB DN Logic 960 lw Date setting for timer Date 15 October 2014 Ev Wednesday m 11 o 0 E i E hh mm ss Broadcast Time E Refresh Gannranhic lnestinn catinn The date and time settings from the logic module can also be broadcast to other devices in the HDL Buspro network this is made possible by simply ticking the Broadcast Time check box 4 3 2 Geographic location settings The geographic location of the module can be set in two ways Firstly the latitude and longitude can be input manually and secondly the Location can be selected from a list of countries and their major cities Accurately inputting the location is essential as it enables the system to calculate the Logic timer User Manual User M H D L AE rsbenn sunrise and sunset times Geographic location setting Lat setting F v 39 156 Degree doctor LONG gt Mie 1 23 Dere Time zone GMT 8 fv 00 9 Method For Prayer Times Sunrise Time 06 23 Sunset Time 17 38 4 3 3 Call to prayer Due to the differing methods employed to determine the Adhan you can set the prayer times method according to your country here Dhuhr Maghrib Prayer Time ee Macs 1 j amp _Juristic Methods For Asr prayer Standard Imams Shafii Hanbali and Maliki Hanafi
5. 1 Changing the device ID Every HDL BUS device has one Subnet ID and one Device ID The device ID should be Logic timer User Manual User Manual H D L SB DN Logic960 unique in its subnet and be kept consistent with the Gateway typically the SB DN 1IP or HDL MBUS011P 431 Method One 1 Open the HDL BUS Pro Setup tool software 2 Press the programming button for 3 seconds the LED status indicator will then turn red 3 Using the software click the Address management tab and select the Modify address when device button is pressed the window shown below will then appear Set initial address of equipsent a Inia address of ogupnert Subrat ID indese otal akkora Device ID l Modiy rha godess e Add kad 4 Click on Indicate initial address the device ID will then be shown If you wish to change the address enter your modification and click Modify initial address Clicking on the Add tab will include the device in the online devices list Method Two 1 Open the HDL BUS Pro Setup tool software 2 Click the search button and a new window will appear From this window click Search the online devices then click the Add all tab The device will then be included in the online devices list 4 1 2 Remark It is recommended that you name the module in order to differentiate it from other similar devices 4 2 Configuration As previously mentioned the l
6. K 1 Linked to table 3 At Time 08 00 a UV Switch 21 ON enable disable Saturday Sunday 1 Linked to table 5 At Time 10 00 Each table scene has three conditions a Week type between weekdays b time type specific time c UV switch The tables can be connected to the first table this enables a delay to be set which can increase the song volume gradually Targets output _ Modify type synchronously Edit member in controlled group Parameter 1 Parameter 3 A 208 Switch no On Switch Status Universal switch 2 4 Universal switch 150 Switch no On Switch Status 3 4 101 Universal switch 25 Switch no On Switch Status N A 4 101 Universal switch 21Switch no On Switch Status N A This is for the first table it causes the starting volume to be voice28 UV 219 Configuring the panel Using the panel users are able to send the UV switch command to the logic module to enable disable the scene Key information 2 el 13 v gt Function configuration of current key Funct Subnet ID Device ID Wake m UP Single on off 21 Switch no On Switch Status Universal switch Invalid Logic timer User Manual User M H D L AE rsben 5 5 Application 5 Triggering the next scene when a switch is toggled Requirement Triggering a scene Existing switches can be used to trigger the dimmer scenes To do so a switch should be turned on or off t
7. minutes is possible When the countdown reaches 30 seconds an mp3 voice file will countdown the remaining time Note The countdown voice file must be in mp3 format and should be mounted on the SD card in a folder named special As an example of the naming system used for files below are three examples e 019 timer 1m mp3 e 020 timer 3m mp3 e 021 timer 5Sm mp3 If the universal switch number is 20815019 then e 208 is to select SD card e 150 is to select the folder special e 19 is to select 019 timer 1m mp3 For more information concerning the Universal Switch please refer to the Z Audio list pdf ftp 59 41 255 150 HDL BUS HDL BUS 20Products SB Z Audio Configuring the logic module DelayiS 60 AND Delay 5j 180 AND 5 P 1y UV Switch 24 ON enable disable tim 1 UV Switch 25 ON enable disable tim Logic timer User Manual User M H D L SI rsbenn Target output Modify subnet ID synchronously _ Modify the intensity synchronously Modify device ID synchronously Modify the running time synchronously Modify type synchronously Edit member in controlled group a Z Z SR E Universal sebeb 3 4 101 Universal switch 19 Switch no On Switch Status N A 2 4 101 Universal switch 150 Switeh no On Switch Status Configuring the panel Curent key 1 Mode Single on off Input function no f
8. HDL User Manual Logic Timer Module SB DN Logic960 C RoHS SB DN Logic960 DUSDro www hdlautomation com User Manual H D L SB DN Logic960 Document updates KE V1 0 2015 01 26 Finish new document Logic timer User Manual User M H D L ben INDEX EO EEE EEE SE EE 1 1 1 General lnformation LLL k rek keke K Ke kK K k 1 Derd EEA EE OEE EASA ES EEEN EEE EEEE 1 VTM 1 iy rererere E SEEN EEEE TEE E EE E EEEE AES EAEE EE E 1 1 3 PENE Nese ee 2 ABID ea or INA EE NE 2 D EE EP r rrr NESEN 3 4 Software Configuration L Ei E eee keke keke kerek k kek re K KK KEK KK ARA 3 4 1 PN 3 4 1 1 Changing the device lD kek k k ke ke 4 ta EN N N NNN N NHNHnNENnNnNnNnEnE nRNnE na n nRnRaRa n EznN DJ zi n 4 Go Le gt gt gt eo aoxoo0omnn nenonpenepxnxnoo ooeoeoonDnhnh meoa ann 4 4 2 1 Equipment Activation cccccccsssssscccssssscecessssseeecssseeeeessssaseceseseaeeeesessaeecesseaaes 5 yaya MOEN Ol ONG S NNNMNM VD DEDEMN NN MNmNmNmzrmzrxrzxN N gt MDN nNDa Iio 2 592o 5 4 2 3 Additional settingsS u eker ke ee k kek keke ke 11 4 3 System sett n gsS E keke kek ke ek ek ke k k e kk ke k kk kaz 12 4 3 1 Setting the timMe ccccccccecessecseesesscecceecescnsceeessssn
9. atically detect Retrigger Enable Exterior universal status b Type mr Exterior subnet ID Exterior device ID UV Switch switch status Logic timer User Manual User M H D L AE rsben j Device channel status This is used to read the dimmer relay channel status when the channel is ON or OFF a logic command can be sent to trigger a target Modify pin configuration Base infomation Subnet ID 6 Logic number 6 Modify relation of input pins sa 00 ESH HH MM SS Exterior subnet ID Exterior device ID Channel Channel status k Device curtain status The curtain status can be used as a logic condition this enables a target to be triggered when the curtain is ON or OFF Modify pin configuration Base information Subnet ID 6 Logic number 6 Modify relation of input pins Relation mj E 100 es HH MM SS Automatically detect Retrigger Enable Logic timer User Manual User M H D L Ma Luc c0 Panel status The logic module can read the status of the panel among the features it can monitor are IR status lock status temperature status and AC mode m Security settings This is to read the status of the security module arming situation Modify pin configurati
10. e D Logic number 6 Logic table number Modify relation of input pins Relation ANI ce Delay o 0 00 Mmm ss Modify input pin configuration Select input pin ro xl Atomatically detect Retrioger Enable Device scene status ej Type Extenor subnet ID Extenor device ID Area Scene Logic timer User Manual User M H D L AE rsben h Device sequence status The dimmer and relay sequence status can be set as a logic condition This allows a target to be triggered when a sequence is being triggered Modify pin configuration Subnet ID Logic number Modify relation of input pins Relation AND i mj Delay Modify input pin configuration Select input pin Type Exterior subnet ID Bderior device ID Area Sequence i Exterior universal status This allows the monitoring of an external universal switch and the sending of commands according to the UV switch status Modify pin configuration Base information Subnet ID 6 Device ID 14 Model SB DN Logic960 Logic number 6 Logic table number 1 Modify relation of input pins Edl Relation AND zn ll T o 5 3 Delay om jo j0 HHMMSS 4 Modify input pin configuration Select input pin 1 el autom
11. eceeeesecccecsesscscceessseneeeeesaes 12 4 3 2 Geographic location settigsS iE ek ek ekes 12 EG ls elel Dd c zgg EE i 13 4 3 4 Summer time settingS keke k k k k e ke 13 lT z o2 gt gt gt pn o x H HEHEFPr HN N NE n Dw nwmmmmmneem 14 5 1 Application 1 Irrigation scheduling L L Liii ek 14 5 2 Application 2 Birthday reMaindel ccccesscccessceceseseeeseseeeeseecesseeeeeeseeeeessaeeesas 15 5 3 Application 3 Cooking timer E eke ek ek e 17 5 4 Application 4 Wake up SCene ddEEE Ek ek keke Keke k 18 5 5 Application 5 Triggering the next scene when a switch is toggled 20 NTE L 22 Logic timer User Manual User M H D L ben 1 Overview 1 1 General Information 1 1 1 Description HDL SB DN Logic960 is an intelligent programmable logic controller The module is able to automatically control scenes channel status input status date time etc The SB DN Logic960 also has AND OR NAND and NOR logic blocks that can be used for a variety of applications With the modules real time clock schedules can also be created 1 1 2 Mounting HDL 930mm 35mm 72mm 66mm e Standard 35mm Din Rail Installation e Inside Distribution Box DB 1 2 Functions e Supports 12 logic groups with each group havi
12. et on the system settings tab e Universal switch Enables general communication between all modules some devices can send out a UV switch to the logic module allowing a UV switch to be used as an input condition Modify pin configuration j lea Base irformatior Subnet ID 6 Device ID 14 Model SB DN Loagic 960 Logic number 65535 Logic table number 1 Modify relation of input pins E lt Lamer i Delay loo 00 oo munn ss a Modify input pin configuration V Automatically detect Retrigger Enable Select input pin Type Logic timer User Manual User M H D L AE rsben f Exterior input value This function allows the detection of an output value currently it is solely used for temperature Modify pin configuration Base information Subnet ID Device ID Logic number Logic table number Modify relation of input pins Exterior subnet ID Exterior device ID Control NO Control value g Device scene status The device scene status enables the scene status from a dimmer or relay to be used as a logic condition This allows a target to be triggered when a scene is being triggered Enter the subnet device ID of the target module as well as the area and scene number Modify pin configuration Base infomation Subnet ID 6 Devic
13. his will then activate the next scene gt Switch toggled gt scene2 gt Switch toggled gt scene3 gt Switch toggled gt scene1 a i ji Dry Contact 7 An aw ii 2 ie gt G Logic Module Dimmer Configuring the logic module Setup the logic tables with the desired outputs each logic should have two pins two conditions and both of them should be set as the UV switch Delay 5 0 AND y SJ O Delay 5 AND 5 5 UV Switch 2 LON toggle switch UY Switch 21 ON toggle switch UY Switch 21 toggle switch UV Swite foon UV SwitohT ON UV men 1 3 N B The Automatically detect re trigger enable option should be ticked selected in each logic table Targets output Each logic table will send the following a OFF command to UV switch 21 common UV switch for all the three tables Logic timer User Manual User M H D L a Luc 0 b ON command to the next table UV switch and off to the other 2 tables c Also turn ON a specific scene Below the output from table 1 is shown C Modify subnet ID synchronously L Modify the intensity synchronously C Modify type synchronously Edit member in controlled group E F y 3 Member no Subnet ID Device ID Type Parameter 1 Parameter 2 Parameter 3 3 3 81 Universal switch 21 Switch no Off Switch Status N A 4 3 a1 Universal switch 10 Switch no Off Switch Sta
14. k type Sunday 2 time type 9am and 3 UV 19 should be ON Target output The target relay must set as ON Logic timer User Manual User M H D L a rsbenn Modify device ID synchronously Modify the running time synchronously gt JIR 100 Intensity 0 0 Running time mm ss Logic 2 Logic 2 is linked with logic 1 to enable logic 2 a user should a Right click on logic 1 and select confirm start point then b Right click on Logic 2 and select confirm end point Target output The target must be set as OFF Single channel lighting control Channel no lIntensty U 0 Running time mm ss hdd IRE Ai AL A Panel configuration A user should assign one button to send the specified UV switch to the logic module this allows the panel to enable or disable the schedule To do this the mode should be set as Single ON OFF Curertkey 1 Mode Single on off input functionmo from 1 Universal switch 19 Switch no On Switch Status Single on off 5 2 Application 2 Birthday remainder Requirement A user wishes to set a reminder If a user wishes to set a reminder for birthdays or other special occasions a voice reminder can be given by the SB Z Audio or HDL MZBOX 20 Logic timer User Manual User M H D L SI rsbe Note The voice reminder files must be in mp3 fo
15. ng 20 logic tables e Each logic table can set 4 logic input conditions and 20 input targets e Logic input conditions are as follows time date year week scene working status external device input status wall panel status and security status e The supported logic relations are AND OR XOR NAND Logic timer User Manual User Manual H D L SB DN Logic960 1 3 Device Description HDL eo a LED indicator S b Programming button E KEMAL c HDL Buspro interface 2 Technical Data Electric Parameters Bus power DC12 30V Bus power consumption 15mA DC24V Environmental Conditions Working temperature 5C 45C Working relative humidity Up to 90 Storage temperature 20 C 60 C Storage relative humidity Up to 93 Approved CE RoHS Production information Dimensions 72x88x66 mm Installation 35mm Din Rail installation Protection degree IP20 Logic timer User Manual User M H D L SUN p 3 Wiring Please strictly follow the wiring diagram shown below SSO SS Sere HDL wr j J _ I_ DATA DATA DC24V UL _ HDL Buspro 4 Software Gonfiguration 4 1 Basic settings 2 A channels 10A relay 1 vere Devices 2 Area it nn 4 er sr gt J lt J L reza e 1 42 HDLMROAD 431 8000 D4 10 63 81 1F 2A 4 1
16. ogic module is used to automate other HDL modules In the following units setting up a logic table with input conditions will be explained Logic timer User Manual User Manual HDL SB DN Logic960 4 2 1 Equipment activation If the Equipment activation tick box remained unchecked then the logic module will be disabled 4 2 2 Input conditions It is necessary to first select a logic table from the logic No drop down box after this is done clicking on the black area will start the configuration A logic relation AND OR XOR NAND must be selected according to your requirements Basic information Configuration System setting Select device Set Logic Device 6 14 5B DN Logic960 v Equipment activation Save Logic NO rai 1 2 3 4 5 8 F 10 11 12 The logic module is an adaptable and flexible automation device as such there are multiple input conditions that can be used to achieve different logic states Each logic table can have a maximum of four input conditions Below the four logic inputs are explained Logic timer User Manual User M H D L AE rs Modify pin configuration EE Base information Subnet ID 6 Device ID 14 Model SB DN Logic960 Logic number 65535 Logic table number 1 TModify relation of input pins 1 Relation AND m T2 mme _ 5 3 Delay jo oo oo EB HH MM SS 2 Modify input pin configuration
17. on X Base information Subnet ID 6 Device ID 14 Model SB DN Logic960 Logic number 6 Logic table number 1 Modify relation of input pins 1 ae mme ps ANE el Fa Delay o E foo 00 M HHmMSS 3 Modify input pin configuration Select input pin E ste Automatically detect Re trigger Enable Security Setting Type Subnet ID G Device ID 80 Area Type r gt Nig Night with guest ay OFF Disarm 4 2 3 Additional settings a Setting a time delay If a time delay has been set and a trigger is activated the output will be delayed according to the delay time set in the logic table b Automatically detect re trigger enable If this option is selected it will enable the logic module to re trigger the target after it receives a command no matter the target is already triggered or not Logic timer User Manual User M H D L AE rsbenn Modify input pin configuration Select input pin 1 e lt Automatically detect Re rigger Enable Type Subnet ID 6 Device ID 80 Area ze 4 3 System settings 4 3 1 Setting the timer The logic module must be configured with the correct time and date this can be done automatically via a PC by simply clicking on PC time and then clicking save The correct date and time is essential as they are used as the standard time settings for
18. rmat and should be put on the SD card in a folder named special As an example of the naming system used for files below are three examples e 015 birthday grandma mp3 e 016 birthday me mp3 e 017 birthday wife mp3 If the universal switch number is 20815015 then e 208 is to select the SD card e 150 is to select the folder special e 15 is to select 015 birthday grandma mp3 For more information concerning the Universal Switch please refer to the Z Audio list pdf ftp 59 41 255 150 HDL BUS HDL BUS 20Products SB Z Audio Configuring the Logic module No 1 Mam birthday tomotro Delay S 0 AND m At Day 201 4 4 20 At Time 19 00 Set the pin as year type then select specific date Target output C Modify subnet ID synchronously Modify the intensity synchronously C Modify device ID synchronously C Modify the running time synchronously Modify type synchronously Edit member in controlled group Parameter 3 Universal switch 208 Switch no 2 4 101 Universal switch 150 Switch no On Switch Status N A On Switch Status 3 4 101 Universal switch 19 Switch no On Switch Status N A Logic timer User Manual User M H D L ME Luc0 5 3 Application 3 Cooking timer Requirement A user wishes to time a specified event Multiple timers can be set using the logic 960 module the timing of 1 minute 3 minutes 5 minutes 10 minutes and 30
19. rom 1 la Key information 12 og Pae seal configuration of current key Key Remark eg Mode Fun Subnet DC Tye Parameter enable Dish2timer Single on off Single on off Cinala an dt enable Dish3timer 5 4 Application 4 Wake up scene Requirement Alarm clock If a user wishes to wake up every weekday at 8 am and every weekend at 10 am the system can be programmed to open the curtains and play a specific song The end user is able to enable disable the wake up scene the night before it is scheduled and stop the music with a press of a button Note The song used by the alarm must be in mp3 format and should be mounted on the SD card in a folder named special An example of the naming system that must be used is O25 wakeup mp3 To activate the alarm song the universal switch number must first trigger it If the universal switch number is 20815025 then e 208 is to select the SD card e 150 is to select the folder special e 25 is to select 025 wakeup mp3 Logic timer User Manual User M H D L AE a For more information concerning the Universal Switch please refer to the Z Audio list pdf ftp 59 41 255 150 HDL BUS HDL BUS 20Products SB Z Audio Note 215 to 224 is for volume control minimum to maximum respectively No 1 starting volume 28 No 3 volume 39 No 4 vom Delay sjo0 AND Delas i0 AND Delay S ay AND Monday Friday Ps 1 Linked to table 1
20. tus N A 5 3 81 Universal switch On Switch Status N A 6 3 81 Universal switch 12 Switch no Off Switch Status N A 7 3 103 Area no Scene no N A Table 2 output _ Modify type synchronously Edit member in controlled group lili j Universal switct 21 Switeh ne Off Switch Status Universal switch 10 Switch no Off Switch Status 81 Universal switch 11 Switch no Off Switch Status N A 81 Universal switch Cwtch no ps On Switch Status N A 103 r Area no 3 N A wl wl vu vik Table 3 output Modify type synchronously Edit member in controlled group i 5 u m mm Inversal swich 3 Universal switch ae 0N Switch Status 3 Universal switch 11iSwiteh no Off Switch Status NAA 3 81 Universal switch 12 Switch no Off Switch Status N A 3 103 vesen N A Configuring the dry contact The dry contact uses three switches channels to send commands to the logic module via the UV switch In the example UV 21 is set this means that the dry contact can send commands to all three tables because they all share the designation UV 21 N B Two mechanical switches should be used one mechanical switch for ON and one mechanical switch for OFF The output UV switch status from both should be ON Switch information 1arget ntormat on ar the curent state c INE cument Switch Switch No Type