Home

S9 AutoSet™ / S9 AutoSet™ for Her / S9 Elite™ / S9 Escape™ / S9

image

Contents

1. la lumi re directe du soleil afin d viter qu il ne durcisse ou ne se fissure avec le temps Ne pas laver le filtre air Il n est ni lavable ni r utilisable Le couvercle du logement du filtre air prot ge l appareil contre tout d versement accidentel de liquides Veillez ce que le filtre air et le couvercle de son logement soient toujours en place basses pressions le d bit aux orifices de ventilation de votre masque peut s av rer insuffisant pour expulser tous les gaz expir s hors du circuit respiratoire Une r inhalation peut se produire La temp rature du d bit d air produit par cet appareil peut tre sup rieure de 6 C 11 F la temp rature ambiante Des pr cautions particuli res devront tre prises lorsque la temp rature ambiante est sup rieure 32 C 90 F 1 En cas de d faillance de l alimentation en dessous de la tension nominale minimale ou de coupure de courant les pressions de traitement ne sont pas d livr es Le fonctionnement reprend normalement une fois l alimentation r tablie A AVERTISSEMENTS CONCERNANT IH5i LH5i est con u pour tre utilis seulement avec les appareils de la s rie S9 Ne pas utiliser l H5i avec d autres appareils de PPC Ne pas utiliser l H5i sil ne fonctionne pas correctement ou si l une de ses pi ces ou de celles de l appareil de pression positive est tomb e par terre ou a t endommag e L H5i doit tre utilis uniquement avec les circuits r
2. Altitude operacional Temperatura de armazenamento e transporte Umidade de armazenamento e transporte Compatibilidade eletromagn tica Uso em aeronaves Classifica o IEC 60601 1 52 Eleve Reduza a temperatura do tubo aquecido atrav s do menu Varia o da alimenta o de 100 240 V 50 60 Hz Nominal para uso em aeronaves 110 V 400 Hz Consumo de energia t pico 70 W 80 VA Consumo de energia m ximo 110 W 120 VA Varia o da alimenta o de 100 240 V 50 60 Hz Nominal para uso em aeronaves 110 V 400 Hz Consumo de energia t pico 20 W 30 VA Consumo de energia m ximo 36 W 75 VA 5 C a 35 C 41 F a 95 F 10 a 95 sem condensagao Nivel do mar at 2 591 m 8 500 p s 20 C a 60 C 4 F a 140 F 10 a 95 sem condensa o O produto encontra se em conformidade com todos os requisitos de compatibilidade eletromagn tica EMC de acordo com o IEC 60601 1 2 para areas residenciais comerciais e de ind stria leve As informa es sobre imunidade e emiss es eletromagn ticas destes dispositivos ResMed podem ser encontradas em www resmed com na p gina Products Produtos em Service and Support Servi o e Suporte Clique no arquivo PDF para o seu idioma A ResMed garante que a Linha S9 atende s exig ncias da Administra o Federal de Avia o FAA dos EUA RTCA DO 160F em todas as fases do deslocamento a reo Classe Il isolamento duplo Tipo BF Especifica es t
3. Desempenho do umidificador As configura es que seguem foram testadas a 22 C temperatura ambiente Sa da de UA do sistema nominal Press o na 9 fi mascara CPAP HS BTPS cm H20 Configura o 3 Configura o 6 Configuragao 3 Configura o 6 4 90 100 10 18 10 95 100 11 5 21 20 95 100 11 18 a UA Umidade Absoluta em mg l b BTPS temperatura corporal press o ambiente saturado com vapor d gua Simbolos Os s mbolos a seguir podem aparecer no a S9 H5i fonte de alimenta o tubo de ar ou embalagem A Cuidado Leia as instru es antes de usar AE Siga as instru es de uso 4 A prova de gotejamento PX0 N o a prova de gotejamento Equipamento tipo BF Equipamento de Classe Il 5 Iniciar Parar ml Fabricante EC REP Representante autorizado na Uni o Europeia LA RoHS europeu LoT C digo do lote REF N mero de cat logo sn mero de s rie Corrente cont nua a N o deve ser usado com mais de um paciente MAX N vel m ximo de ees agua Pode ser desinfetado at 93 C 200 F a nm Travar Destravar ls 08 Remover reservat rio para encher Rx Only Somente com prescric o Nos EUA a lei federal limita a venda destes dispositivos a m dicos ou por ordem destes Ca Use somente gua destilada ou deionizada O Logotipo de controle de polui o chinesa 1 DD Logotipo de controle de polui o chi
4. NZ 527088 US 6935337 US 7614398 Other patents pending Protected by design registrations AU 331676 AU 331677 CN 200930203243 5 EU 1720582 JP 1402844 JP 1402845 NZ 413752 NZ 413753 US D626642 US D627044 Other designs pending S9 H5i SlimLine ClimateLine SmartStart are trademarks of ResMed Ltd S9 and SmartStart are registered in U S Patent and Trademark Office 2011 ResMed Ltd 368515 1 2011 07 Global leaders in sleep and respiratory medicine www resmed com
5. ResMed recomienda que la inspecci n y mantenimiento del S9 y del H5i est n a cargo de un centro de servicio autorizado de ResMed si hubiera alg n signo de desgaste o alguna inquietud respecto al funcionamiento del equipo De lo contrario por lo general no es necesario revisar ni realizar mantenimiento del dispositivo durante los cinco a os de vida til esperada Garant a limitada ResMed Ltd en adelante ResMed garantiza que el producto ResMed que usted posee estar libre de todo defecto de material y mano de obra durante el plazo estipulado a continuaci n a partir de la fecha de adquisici n Producto plazo de la garantia e Sistemas de mascarillas incluidos el armaz n de la mascarilla la 90 d as almohadilla el dispositivo para la cabeza y el tubo excluidos los dispositivos descartables e Accesorios excluidos los dispositivos descartables e Sensores de pulso digitales flexibles e Cubetas de agua para humidificadores e Bater as para usarse en los sistemas de bater as internos y externos de 6 meses ResMed e Sensores de pulso digitales de tipo pinza 1 a o dulos de datos de dispositivos CPAP y binivel e Ox metros y adaptadores de oximetros de dispositivos CPAP y binivel e Cubetas de agua lavables para humidificadores e Dispositivos de control de titulaci n e Dispositivos CPAP binivel y de ventilaci n incluidas las fuentes de 2 a os alimentaci n externas e Accesorios para bater as e Di
6. 3 ClimateLine MAX 19 mm de diam tre interne Circuit respiratoire SlimLine Plastique flexible 1 8 m 6 15 mm de diam tre interne Circuit respiratoire standard Plastique flexible 2 m 6 6 19 mm de diam tre interne Temp rature de coupure du circuit lt 106 F lt 41 C respiratoire chauffant Remarques Le fabricant se r serve le droit de modifier ces caract ristiques sans notification pr alable Les valeurs de temp rature et d humidit relative indiqu es pour le circuit ClimateLine ClimateLine ne sont pas mesur es e Contactez votre clinicien ou prestataire de sant avant d utiliser le circuit respiratoire SlimLine avec d autres appareils que la S9 ou I H5i 23 24 Performance d humidification Les r glages suivants ont t test s a une temp rature ambiante de 22 C ene i Humidit absolue du syst me O Presson RT au Humidit relative nominal HA BTPS masque cm H20 R glage 3 R glage 6 R glage 3 R glage 6 4 90 100 10 18 10 95 100 11 5 21 20 95 100 11 18 a HA Humidit absolue en mg l b BTPS de l anglais Body Temperature Pressure Saturated la pression et la temp rature corporelles et satur de vapeur d eau Symboles Les symboles suivants sont susceptibles de se trouver sur votre S9 votre H5i le module d alimentation votre circuit respiratoire ou l emballage A Attention Lire les instructions avant utilisation CA Suivez les instructions
7. ar em m quinas de lavar roupas ou m quinas de lavar lou a e O dispositivo ClimateLine ou ClimateLine foi projetado exclusivamente para uso com o HBi sl Manufacturer ResMed Ltd 1 Elizabeth Macarthur Drive Bella Vista NSW 2153 Australia Distributed by ResMed Corp 9001 Spectrum Center Boulevard San Diego CA 92123 USA EC REP ResMed UK Ltd 96 Milton Park Abingdon Oxfordshire 0X14 4RY UK See www resmed com for other ResMed locations worldwide S9 Protected by one or more patents AU 691200 AU 697652 AU 702820 AU 709279 AU 724589 AU 730844 AU 736723 AU 750095 AU 750761 AU 764761 AU 779327 AU 2007252223 CN 200780001837 6 EP 0651971 EP 0661071 EP 0920845 EP 0927538 EP 0934723 EP 1028769 EP 1126893 EP 1144036 EP 1502618 EP 2032857 JP 3580776 JP 3778797 JP 4647786 NZ 504595 NZ 570415 NZ 573921 NZ 577485 US 5704345 US 6138675 US 6240921 US 6363933 US 6367474 US 6425395 US 6502572 US 6591834 US 6675797 US 6745768 US 6817361 US 6988498 US 7040317 US 7100608 US 7537010 US 7866944 Other patents pending Protected by design registrations AU 329025 AU 330142 AU 331272 AU 332891 AU 333858 CN 200830346524 1 CN 200830346526 0 CN 200830346525 6 CN 201030215797 X EU 1067417 JP 1377401 JP 1377402 JP 1377403 NZ 411762 NZ 413090 NZ 413091 US D629891 US D629892 US D635232 US D635244 US D635245 US D635654 Others pending H5i Protected by patents AU 2002233025 CN ZL02804936 5 HK 1065483 JP 4420605
8. circuit respiratoire et ou de l entr e d air de la S9 pendant le fonctionnement risque de causer une surchauffe de l appareil Si votre clinicien vous a demand d utiliser la carte SD pour mettre les r glages de votre appareil jour et si le message Mise jour r ussie des r glages ne s affiche pas veuillez contacter votre clinicien imm diatement Un patient ne doit connecter aucun appareil au port de connexion du module sauf si son prestataire de sant ou son m decin lui a demand de le faire Seuls les produits ResMed peuvent tre connect s au port de connexion du module La connexion d autres appareils peut causer des blessures ou endommager la S9 Ces S9 doivent tre utilis es uniquement avec les masques et raccords recommand s par ResMed un m decin ou un inhaloth rapeute Le masque ne peut tre port que si la S9 est sous tension Apr s la mise en place du masque v rifiez que l appareil produit un d bit d air Les orifices de ventilation du masque ne doivent jamais tre obstru s Explication Votre S9 est con ue pour tre utilis e avec des masques ou raccords sp ciaux poss dant des orifices de ventilation qui permettent l coulement continu de l air hors du masque 1 Des orifices peuvent tre compris dans le masque ou les connecteurs qui sont pr s du masque 27 28 Lorsque l appareil est sous tension et qu il fonctionne correctement de l air propre provenant de l appareil expulse l air e
9. coberta por roupa de cama pe as de vestu rio ou outros itens Exibe a mensagem de erro Tubo obstru do Verifique o tubo O tubo de ar est obstru do Verifique o tubo de ar e remova eventuais obstru es Exibe a mensagem de erro Fuga alta Verifique a montagem do sistema e todas as conex es A fuga de ar excessiva Ajuste a posi o da m scara e do arn s O tubo de ar n o foi conectado adequadamente Conecte firmemente em ambas as extremidades A tampa articulada do Hbi n o est Feche a tampa articulada certificando se de ouvir o clique corretamente travada de encaixe Exibe a mensagem de erro Feche a tampa articulada do H5i fixe o tubo e pressione qualquer tecla A tampa articulada do Hbi n o est Feche a tampa articulada certificando se de ouvir o clique fechada de encaixe Problema possivel causa Solu o O tubo de ar n o foi conectado Conecte firmemente em ambas as extremidades adequadamente A mensagem a seguir exibida no visor LCD depois que voc tentar atualizar configura es ou copiar dados para o cart o SD Erro de cart o Remova o cart o SD e contate o prestador de servi os O cart o SD n o foi introduzido Certifique se de que o cart o SD foi introduzido corretamente corretamente Voc pode ter removido o cart o SD Reintroduza o cart o SD e aguarde a tela inicial ou a antes das configura es terem sido mensagem Configura es atualizadas com xito copiadas para o dispositivo C
10. d alimentation en question et remplacez marque que ResMed est branch le par un module ResMed l appareil La literie recouvre le module Veillez ce qu il n y ait rien sur le module d alimentation d alimentation Affichage du message d erreur Circuit obstru veuillez v rifier votre circuit Le circuit respiratoire est obstru V rifiez le circuit respiratoire et retirez tout l ment qui l obstrue 19 20 Probl me cause possible Solution Affichage du message d erreur Fuite importante veuillez v rifier le montage du syst me et toutes les connexions Il y a une fuite excessive Ajustez la position du masque et du harnais Le circuit respiratoire n est pas correctement raccord Connectez fermement les deux extr mit s Le couvercle rabattable de l H5i n est Fermez le couvercle rabattable en vous assurant qu il se pas verrouill correctement verrouille en position Affichage du message d erreur Veuillez fermer le couvercle rabattable de l H5i fixer le tube et appuyer sur une touche quelconque Le couvercle rabattable de l H5i n est Fermez le couvercle rabattable en vous assurant qu il se pas ferm verrouille en position Le circuit respiratoire n est pas Connectez fermement les deux extr mit s correctement raccord Le message suivant s affiche sur l cran ACL apr s que vous avez essay de mettre les r glages jour ou de copier des donn es sur la carte SD Erreur de carte veuillez enleve
11. d utilisation 4 Protection anti gouttes IPX0 Absence de protection anti gouttes quipement de type BF quipement de classe II 0 D marrer arr ter ml Fabriqu par EC REP Repr sentant autoris dans Union europ enne Le RoHS europ ens LoT Code de lot REF Num ro de r f rence sn Num ro de s rie Courant continu a est pas con u pour tre utilis par plus d un patient MAX Niveau maximum d eau Est fi LLED WATER ONLY ou d sionis e a nm Verrouiller d verrouiller 6308 Retirez la cuve pour la remplir Rx Only Sur ordonnance uniquement selon la loi f d rale am ricaine cet appareil ne peut tre vendu d sinfect a une temp rature allant jusqu a 93 C 200 F Utilisez seulement de l eau distill e aux Etats Unis que par un m decin ou sur prescription m dicale O Logo 1 de contr le de la pollution pour la Chine DD Logo 2 de contr le de la pollution pour la Chine Entretien Les appareils S9 et H5i sont con us pour fonctionner de fa on s curitaire et fiable lorsqu ils sont utilis s conform ment au mode d emploi fourni par ResMed ResMed recommande de faire inspecter et r parer la S9 et l H5i par un centre de service ResMed autoris en cas de signes d usure ou de pr occupations li es au fonctionnement de ces appareils Autrement la r paration et l inspection de ces appareils ne devraient n
12. mm inner diameter Heated tubing temperature cut out lt 106 F lt 41 C Notes The manufacturer reserves the right to change these specifications without notice The temperature and relative humidity settings displayed for ClimateLine or ClimateLine measured values Check with your clinician service provider before using the SlimLine air tubing with devices other than the S9 or H5i MAX are not Humidifier performance The following settings have been tested at 22 C ambient temperature CPAP mask RH output Nominal system output AH BTPS gt pressure cm H20 Setting 3 Setting 6 Setting 3 Setting 6 4 90 100 10 18 10 95 100 115 21 20 95 100 11 18 a AH Absolute Humidity in mg L b BTPS Body Temperature Pressure Saturated Symbols The following symbols may appear on your S9 H5i power supply unit air tubing or packaging A Caution Read instructions before use AR Follow instructions for use Drip proof IPX1 IPXO Not drip proof Type BF equipment Class Il equipment 5 Start Stop ml Manufacturer EC REP European Authorised Representative LA European RoHS Lot Batch code REF Catalogue number sn Serial number Direct current a Not for use on more than one patient MAX Maximum water level Disinfectable up to A DISTILLED WATER NILO 200 F 93 C devices to sale by or on the order of a physi
13. por um nico paciente em ambiente dom stico e reutiliza o por v rios pacientes em ambiente hospitalar ou institucional Indica es de uso do H5i for Her O H5i for Her indicado para a umidificac o do ar fornecido por um dispositivo de CPAP ou de dois n veis O H5i for Her s deve ser usado conforme recomenda o m dica O H5i for Her foi projetado para reutiliza o por um nico paciente em ambiente dom stico e reutiliza o por v rios pacientes em ambiente hospitalar ou institucional Contraindica es do H5i O H5i contraindicado para uso com pacientes cuja via respirat ria superior supragl tica tenha sofrido by pass Resolu o de Problemas Se ocorrer um problema experimente as sugest es a seguir Se n o for poss vel resolver o problema contate o seu fornecedor de equipamento ou a ResMed N o tente abrir estes dispositivos Problema poss vel causa Solu o O visor n o funciona A unidade n o se encontra conectada a Verifique se o cabo de energia est conectado e se a uma fonte de energia tomada de alimenta o se dispon vel tem energia O plugue CC n o est totalmente Insira o plugue CC at o final inserido na parte posterior do dispositivo O S9e o H5i n o est o conectados Certifique se de que o S9 e o H5i est o conectados com corretamente firmeza 47 48 Problema possivel causa Solu o O ar fornecido pelo dispositivo S9 insuficiente O Tempo de Rampa est em
14. selected via the menu Device does not start when you breathe into the mask Breath is not deep enough to trigger Take a deep breath in and out through the mask SmartStart Stop There is excessive leak Adjust position of mask and headgear Air tubing not connected properly Connect firmly at both ends Problem possible cause Solution SmartStart Stop is disabled Enable SmartStart Stop Note SmartStart Stop is not available in S9 Escape and S9 Escape Auto Device does not stop when you remove your mask SmartStart Stop is disabled Enable SmartStart Stop Note SmartStart Stop is not available in S9 Escape and S9 Escape Auto SmartStart Stop is enabled but the device does not stop automatically when you remove your mask Incompatible mask system being used Only use equipment recommended by ResMed The patient is using a nasal pillows Disable SmartStart Stop mask with a set pressure less than 7 cm H20 Pressure rises inappropriately Talking coughing or breathing in an Avoid talking with a nasal mask on and breathe as normally unusual manner as possible Mask cushion is buzzing against the Adjust the headgear skin Displays error message Heated tube fault replace tube Device has been left in a hot Allow to cool before re use Disconnect the power cord environment and then reconnect it to restart the device There is a fault in your ClimateLine or Discontinue using your ClimateLine or ClimateLine air Cli
15. uso O filtro de ar est sujo O tubo de ar n o foi conectado adequadamente Tubo de ar obstru do prensado ou perfurado A m scara e o arn s n o foram posicionados corretamente A tampa articulada do H5i n o est corretamente travada A veda o da tampa articulada do H5i n o est corretamente encaixada O tubo de ar incorreto foi selecionado Aguarde o aumento da press o do ar ou altere o tempo de rampa Substitua o filtro de ar Verifique o tubo de ar Desobstrua ou libere o tubo de ar Verifique se o tubo de ar est perfurado Ajuste a posi o da m scara e do arn s Feche a tampa articulada certificando se de ouvir o clique de encaixe Verifique se a veda o da tampa est voltada para o lado certo para cima e encaixada com firmeza Se estiver usando o tubo de ar SlimLine ou Standard certifique se de que o tubo de ar correto foi selecionado no menu O dispositivo n o come a a funcionar quando voc respira pela m scara A respira o n o suficientemente forte para acionar o SmartStart Stop A fuga de ar excessiva O SmartStart Stop est desativado Observa o O SmartStart Stop n o est dispon vel no S9 Escape e S9 Escape Auto Inspire e expire profundamente atrav s da m scara Ajuste a posi o da m scara e do arn s Tubo de ar conectado incorretamente Conecte firmemente em ambas as extremidades Ative o SmartStart Stop O dispositivo n o para quand
16. 153 mm x 140 mm x 86 mm 6 0 x 5 5 x 3 4 835 g 1 8 lb Thermoplastique ignifug D bit d oxyg ne suppl mentaire maximum recommand 4 I min Fibres acryliques et de polypropyl ne non tiss es avec un support en polypropyl ne Filtre a air standard Fibre de polyester Sortie d air Le raccord conique 22 mm de sortie d air est conforme la norme ISO 5356 1 Caract ristiques techniques de I H5i Temp rature maximale de la plaque 65 C 150 F chauffante Temp rature de coupure 74 C 165 F Temp rature maximale du gaz lt 106 F lt 41 C Dimensions nominales L x x H Station d accueil et r servoir d eau 153 mm x 145 mm x 86 mm 6 0 x 5 7 x 3 4 Poids r servoir d eau Station d accueil et r servoir vide 0 67 g 1 5 lb Poids r servoir d eau nettoyable Station d accueil et r servoir vide 0 77 kg 1 7 Ib Capacit Jusqu au rep re de niveau maximum 380 ml Station d accueil Thermoplastique ignifug aluminium R servoir d eau nettoyable njection moul e en plastique acier inoxydable et joint de silicone R servoir d eau njection moul e en plastique aluminium et lastom re hermoplastique Caract ristiques techniques du circuit respiratoire Circuit respiratoire chauffant Plastique flexible et composants lectriques 2 m 6 6 ClimateLine 15 mm de diam tre interne Circuit respiratoire chauffant Plastique flexible et composants lectriques 1 9 m 6
17. 8 a AH Absolute Humidity humedad absoluta en mg l b BTPS Body Temperature Pressure Saturated temperatura corporal presi n saturada S mbolos Los siguientes s mbolos pueden aparecer en el S9 el H5i la fuente de alimentaci n el tubo de aire o el empaque A Precauci n Lea las instrucciones antes de usarlo CA Siga las instrucciones de uso 4 A prueba de goteo IPX0 No es a prueba de goteo Equipo tipo BF Equipo de clase Il IPX1 5 Inicio detenci n mal Fabricante EC REP Representante autorizado para Europa LA RoHS europeo LoT C digo de lote RE N mero de cat logo SN mero de serie Corriente directa a No debe ser usado por m s de un paciente MAX Nivel m ximo del agua Desinfectable hasta 93 C 200 F Utilice solamente agua destilada o desionizada a nm Bloqueo desbloqueo Retire la cubeta para Ilenarla Rx Only Solo bajo receta en Estados Unidos las leyes federales estipulan que estos equipos solamente pueden ser vendidos por DISTILLED WATER LY 39 40 un m dico o por una orden m dica O Logotipo 1 de control de la contaminaci n en China DO Logotipo 2 de control de la contaminaci n en China Mantenimiento Los dispositivos S9 y H5i est n dise ados para funcionar de manera segura y confiable siempre que se usen de conformidad con las instrucciones suministradas por ResMed
18. 9 Escape Auto Inhale y exhale profundamente a trav s de la mascarilla Ajuste la posici n de la mascarilla y el dispositivo para la cabeza El tubo de aire no est debidamente conectado Con ctelo firmemente en ambos extremos Active la funci n SmartStart Stop Problema Causa posible Soluci n El dispositivo no se detiene cuando usted se quita la mascarilla La funci n SmartStart Stop est Active la funci n SmartStart Stop desactivada Nota El SmartStart Stop no est disponible en el S9 Escape ni en el S9 Escape Auto La funci n SmartStart Stop est activada pero el aparato no se detiene autom ticamente al quitarse la mascarilla Est utilizando un sistema de mascarilla Utilice nicamente el equipo recomendado por ResMed incompatible El paciente est utilizando una Desactive la funci n SmartStart Stop mascarilla nasal de almohadillas con una presi n de referencia inferior a 7 cm de H20 La presi n sube de forma inadecuada Usted habla tose o respira de una Evite hablar cuando tenga puesta la mascarilla nasal y manera inusual respire tan normalmente como sea posible La almohadilla de la mascarilla vibra Ajuste el dispositivo para la cabeza contra la piel y emite un zumbido Aparece un mensaje de error Falla del tubo t rmico reempl celo Se ha dejado el dispositivo en un Permita que se enfr e antes de utilizarlo de nuevo ambiente con temperatura elevada Desconecte el cable de aliment
19. 95 F De 10 a 95 sin condensaci n Desde el nivel del mar hasta 2 591 m 8 500 De 20 C a 60 C de 4 F a 140 F De 10 a 95 sin condensaci n Compatibilidad electromagn tica Uso en aviones Clasificaci n IEC 60601 1 Especificaciones t cnicas del S9 L mites de presi n de funcionamiento Presi n m xima de r gimen permanente suministrada en caso de falla individual Tolerancia en la medici n de presi n Tolerancia en la medici n del flujo El producto cumple con todos los requisitos correspondientes en materia de compatibilidad electromagn tica de conformidad con la norma IEC IEC60601 1 2 para entornos residenciales comerciales y de industria ligera Se puede obtener informaci n acerca de las emisiones electromagn ticas y de la inmunidad de estos equipos de ResMed en el sitio web www resmed com en la secci n de servicio y asistencia que se encuentra en la p gina de productos Haga clic en el archivo PDF correspondiente a su idioma ResMed confirma que la serie S9 cumple con los requisitos de la Administraci n Federal de Aviaci n Federal Aviation Administration FAA de Estados Unidos RTCA DO 160F para todas las fases de los viajes por avi n Clase Il doble aislamiento Tipo BF 4a 20 cm de H20 30 cm de H 0 0 5 cm de H20 4 de la lectura medida 6 I min o 10 de la lectura el que sea mayor VALORES DE EMISION SONORA DECLARADOS MEDIANTE DOS CIFRAS seg n la norma ISO 4871
20. NTS CONCERNANT LES CIRCUITS RESPIRATOIRES En cas de dommages provoquant une fuite du circuit respiratoire ne plus utiliser le circuit respiratoire Ne pas laver le circuit respiratoire dans une machine a laver ou un lave vaisselle Le ClimateLine ClimateLineMAX est con u pour une utilisation uniquement avec l H5i 29 30 Indicaciones de uso del S9 AutoSet El sistema de ajuste autom tico S9 AutoSet est indicado para tratar la apnea obstructiva del sue o AOS en pacientes que pesan m s de 30 kg 66 Ib El sistema de ajuste autom tico S9 AutoSet est dise ado para uso hospitalario y domiciliario Indicaciones de uso del S9 AutoSet for Her El sistema de ajuste autom tico S9 AutoSet for Her est indicado para tratar la apnea obstructiva del sue o AOS en pacientes que pesan m s de 30 kg 66 Ib El sistema de ajuste autom tico S9 AutoSet for Her est dise ado para uso hospitalario y domiciliario Indicaciones de uso del S9 Elite El sistema de presi n positiva y continua en las vias respiratorias CPAP S9 Elite esta indicado para el tratamiento de la apnea obstructiva del sue o AOS en pacientes que pesan m s de 30 kg 66 Ib El sistema CPAP S9 Elite esta dise ado para uso hospitalario y domiciliario Indicaciones de uso del S9 Escape Auto El sistema de ajuste autom tico S9 Escape Auto est indicado para el tratamiento de la apnea obstructiva del sue o AOS en pacientes que pesan m s de 30 kg 66 Ib El siste
21. Nivel de presi n ac stica Nivel de potencia ac stica Dimensiones nominales largo x ancho x alto Peso Construcci n de la carcasa 24 dBA medido seg n la norma ISO 17510 1 2002 26 dBA con una incertidumbre de 2 dBA medido seg n la norma ISO 17510 1 2007 34 dBA con una incertidumbre de 2 dBA medido seg n la norma ISO 17510 1 2007 153 mm x 140 mm x 86 mm 6 0 x 5 5 x 3 4 835 g 1 8 lb Termopl stico de ingenieria ign fuga 37 38 Oxigeno suplementario Filtro de aire hipoalerg nico Filtro de aire estandar Salida de aire Especificaciones t cnicas del H5i Temperatura maxima de la placa de calefacci n Temperatura de desconexi n Temperatura m xima del gas Dimensiones nominales largo x ancho x alto Peso cubeta de agua Peso cubeta de agua lavable Capacidad de agua Estaci n de acoplamiento Cubeta de agua lavable Cubeta de agua Caudal m ximo de ox geno suplementario recomendado 4 I min Fibras de acr lico y polipropileno no entrelazadas con sustrato poroso de polipropileno Fibra de poli ster La salida de aire c nica de 22 mm cumple con la norma ISO 5356 1 65 C 150 F 74 C 165 F lt 106 F lt 41 C Estacion de acoplamiento y cubeta de agua 153 mm x 145 mm x 86 mm 6 0 x 5 7 x 3 4 Estaci n de acoplamiento y cubeta de agua sin llenar 0 67 kg 1 5 lb Estaci n de acoplamiento y cubeta de agua sin llenar 0 77 kg 1 7 Ib Hasta la l nea de nive
22. PAP Pressione qualquer tecla que aparecer no visor LCD Observac o Essa mensagem s aparece uma vez Se voc reintroduzir o cart o SD depois de atualizar as configura es a mensagem n o ser reexibida A mensagem a seguir N O exibida no visor LCD depois que voc tenta atualizar configura es usando o cart o SD Configura es atualizadas com xito Pressione qualquer tecla As configura es n o foram atualizadas Contate imediatamente seu m dico ou prestador de servi os gua proveniente do H5i respinga no seu rosto O reservat rio de gua est cheio Certifique se de que o n vel de gua est abaixo da marca demais de n vel m ximo Forma o de condensa o no tubo de Reduza a intensidade do H5i ou da umidade relativa atrav s ar e na m scara do menu O reservat rio de gua est vazando O reservat rio de gua pode estar Contate seu prestador de servi os para substituir a pe a avariado ou rachado O reservat rio de gua lav vel n o est Verifique se est danificado e remonte o reservat rio de montado corretamente gua lav vel corretamente 51 Problema possivel causa Solu o O ar est muito quente ou frio na m scara A temperatura do tubo de ar do ClimateLine ou ClimateLineMAX est configurada muito alta ou muito baixa Especifica es t cnicas gerais Fonte de alimenta o de 90 W Fonte de alimenta o de 30 W Temperatura operacional Umidade operacional
23. RESMED S9 AutoSet S9 AutoSet for Her S9 Elite S9 Escape S9 Escape Auto POSITIVE AIRWAY PRESSURE DEVICES TM IM H5i H5i for Her HEATED HUMIDIFIER ClimateLine ClimateLine MAX SlimLine Standard AIR TUBING Information Guide English e Fran ais e Espa ol e Portugu s English S9 AutoSet indications for use The S9 AutoSet self adjusting system is indicated for the treatment of obstructive sleep apnea OSA in patients weighing more than 66 Ib gt 30 kg The S9 AutoSet self adjusting system is intended for home and hospital use S9 AutoSet for Her indications for use The S9 AutoSet for Her self adjusting system is indicated for the treatment of obstructive sleep apnea OSA in patients weighing more than 66 Ib gt 30 kg The S9 AutoSet for Her self adjusting system is intended for home and hospital use S9 Elite indications for use The S9 Elite CPAP system is indicated for the treatment of obstructive sleep apnea OSA in patients weighing more than 66 Ib gt 30 kg The S9 Elite CPAP system is intended for home and hospital use S9 Escape Auto indications for use The S9 Escape Auto self adjusting system is indicated for the treatment of obstructive sleep apnea OSA in patients weighing more than 66 Ib gt 30 kg The S9 Escape Auto self adjusting system is intended for home and hospital use S9 Escape indications for use The S9 Escape CPAP system is indicated for the treatment of obstru
24. a asegur ndose de que encaje en su lugar Aparece un mensaje de error Cierre la tapa del H5i conecte el tubo y oprima cualquier tecla La tapa del H5i no est cerrada El tubo de aire no est debidamente conectado Cierre la tapa asegur ndose de que encaje en su lugar Con ctelo firmemente en ambos extremos El siguiente mensaje aparece en la pantalla LCD despu s de tratar de actualizar la configuraci n o copiar datos a la tarjeta SD Error en tarjeta retire la tarjeta SD y comuniquese con el proveedor de servicio La tarjeta SD no est correctamente insertada Es posible que haya retirado la tarjeta SD antes de que la configuraci n se haya copiado en el equipo CPAP Aseg rese de que la tarjeta SD haya sido correctamente insertada Vuelva a insertar la tarjeta SD y espere a que aparezca en la pantalla LCD la pantalla inicial o el mensaje Configuraci n actualizada oprima cualquier tecla Nota Este mensaje solo aparece una vez Si vuelve a insertar la tarjeta SD despu s de haber actualizado la configuraci n el mensaje no volver a aparecer El siguiente mensaje NO aparece en la pantalla LCD despu s de tratar de actualizar la configuraci n usando la tarjeta SD Configuraci n actualizada oprima cualquier tecla La configuraci n no se actualiz Comuniquese inmediatamente con su m dico o proveedor de servicio 35 36 Problema Causa posible El agua del H5i le salpica la cara Se ha sobrepasado
25. aci n y despu s vuelva a conectarlo para poner nuevamente en marcha el dispositivo Existe una falla en el tubo de aire de su Suspenda el uso del tubo de aire de su ClimateLine o ClimateLine o ClimateLine MAX ClimateLine MAX y comuniquese con su m dico o proveedor de servicio Mientras tanto utilice un tubo Estandar o SlimLine 33 34 Problema Causa posible Soluci n Aparece un mensaje de error Falla del humidificador reempl celo Se ha dejado el dispositivo en un ambiente con temperatura elevada Hay una falla en el humidificador t rmico H5i Permita que se enfrie antes de utilizarlo de nuevo Desconecte el cable de alimentaci n y despu s vuelva a conectarlo para poner nuevamente en marcha el dispositivo Deje de usar el H5i y comuniquese con el m dico o proveedor de servicio Aparece un mensaje de error Fallo de temperatura elevada consulte el manual del usuario Se ha dejado el dispositivo en un ambiente con temperatura elevada El filtro de aire est obstruido El tubo de aire est obstruido El nivel de configuraci n del humidificador est demasiado alto lo que provoca una acumulaci n de agua en el tubo de aire Permita que se enfrie antes de utilizarlo de nuevo Desconecte el cable de alimentaci n y despu s vuelva a conectarlo para poner nuevamente en marcha el dispositivo Cambie el filtro de aire Desconecte el cable de alimentaci n y despu s vuelva a conectarlo para poner nue
26. b O sistema auto ajust vel do S9 Escape Auto foi projetado para uso residencial e hospitalar Indica es de uso do S9 Escape O sistema CPAP S9 Escape indicado para o tratamento da apneia obstrutiva do sono AOS em pacientes com peso superior a 30 kg 66 Ib O sistema CPAP S9 Escape foi projetado para uso residencial e hospitalar Contraindica es do S9 O tratamento por press o positiva das vias respirat rias pode ser contraindicado em alguns pacientes com as seguintes doen as preexistentes doen a pulmonar bolhosa grave pneumot rax press o arterial patologicamente baixa e desidrata o e fuga de l quido cerebrospinal trauma ou cirurgia craniana recente Efeitos adversos do S9 O m dico respons vel pelo tratamento deve ser informado caso o paciente sinta dores no peito incomuns fortes dores de cabe a ou agravamento da falta de ar Uma infec o aguda no trato respirat rio superior pode exigir a interrup o tempor ria do tratamento Os seguintes efeitos colaterais podem ocorrer durante o tratamento com esses dispositivos e ressecamento do nariz boca ou garganta sangramento nasal incha o e mal estar no ouvido ou seio nasal e irrita o dos olhos e urtic ria Indica es de uso do H5i O H5i indicado para a umidifica o do ar fornecido por um dispositivo de CPAP ou de dois n veis O H5i s deve ser usado conforme recomenda o m dica O H5i foi projetado para reutiliza o
27. be re displayed The following message is NOT displayed on the LCD after you try to update the settings using the SD card Settings updated successfully press any key The settings were not updated Contact your clinician service provider immediately Water splashing on your face from the H5i The water tub is overfilled Condensation is forming in the air tube and mask Leaking water tub The water tub may be damaged or cracked The cleanable water tub is not assembled correctly Air feels too warm cold in the mask The temperature of the ClimateLine or ClimateLine air tubing is set too high low Check that the water level is below the maximum water level mark Turn the H5i or relative humidity setting down via the menu Contact your service provider for a replacement Check for damage and reassemble the cleanable water tub correctly Turn up down the heated tubing temperature via the menu General technical specifications 90W power supply unit SOW power supply unit Operating temperature Operating humidity Operating altitude Storage and transport temperature Storage and transport humidity Electromagnetic compatibility Aircraft use IEC 60601 1 classification S9 technical specifications Operating pressure range Maximum single fault steady state pressure Pressure measurement tolerance Flow measurement tolerance Input range 100 240V 50 60Hz Nominal for aircraft use 110V 400Hz Typical
28. bes or accessories could result in injury or damage to the device Water must be prevented from entering your CPAP device 1 During partial below rated minimum voltage or total power failure therapy pressures will not be delivered When power is restored operation will recommence with no change to settings Do not overfill the water tub as water may enter the device and air tubing e Take care when handling your H5i as the water water tub may be hot Allow 10 minutes for the heater plate and any excess water to cool The H5i docking station should only be connected or disconnected when the water tub is empty Make sure that the water tub is empty before transporting the H5i Do not operate the H5i on an aircraft as water may enter the CPAP device and air tubing during urbulence Always place the H5i on a level surface below the level of the user to prevent the mask and tubing from filling with water The H5i should be used with caution for users who are unable to remove the mask for themselves If liquids are inadvertently spilled into or on the H5i docking station unplug the device from the power outlet Disconnect the docking station from the CPAP device and allow the docking station to drain and dry before re using ZA AIR TUBING WARNINGS f damage to the air tubing results in air leaking stop using the air tubing Do not wash the air tubing in a washing machine or dishwasher The ClimateLine or Climat
29. cian amp China pollution control logo 1 Use distilled or deionized water only E he Lock unlock 08 Remove tub to fill Rx Only Prescription only In the US Federal law restricts these DO China pollution control logo 2 Servicing The S9 and H5i devices are intended to provide safe and reliable operation when operated in accordance with the instructions provided by ResMed ResMed recommends that the S9 and H5i be inspected and serviced by an authorized ResMed Service Center if there is any sign of wear or concern with device function Otherwise service and inspection of the devices generally should not be required during the five year design life of the device Limited warranty ResMed Ltd hereafter ResMed warrants that your ResMed product shall be free from defects in material and workmanship from the date of purchase for the period specified below Product Warranty period ask systems including mask frame cushion headgear and tubing 90 days excluding single use devices Accessories excluding single use devices e Flextype finger pulse sensors Humidifier water tubs e Batteries for use in ResMed internal and external battery systems 6 months e Clip type finger pulse sensors 1 year e CPAP and bilevel device data modules e Oximeters and CPAP and bilevel device oximeter adapters e Humidifier cleanable water tubs e Titration control devices e CPAP bilevel and ventilation devices including
30. cile ou en milieu m dical Contre indications concernant les appareils S9 Le traitement par pression positive est contre indiqu chez certains patients pr sentant l une des pathologies pr existantes suivantes affection pulmonaire bulleuse grave pneumothorax e hypotension e d shydratation e fuite de liquide c phalo rachidien r cent traumatisme ou intervention chirurgicale cr nienne Effets secondaires li s l utilisation des appareils S9 Les patients doivent avertir leur m decin traitant en cas de douleurs thoraciques inhabituelles de maux de t te s v res ou d une dyspn e accrue Une infection aigu des voies respiratoires sup rieures peut n cessiter l arr t temporaire du traitement Les effets secondaires suivants peuvent apparaitre au cours du traitement utilisant l un de ces appareils e s cheresse nasale buccale ou de la gorge e saignements de nez ballonnements e g ne au niveau de l oreille ou des sinus e irritation des yeux e rythemes cutan s Usage pr vu de l H5i L utilisation de l H5i est indiqu e pour l humidification de l air d livr par un appareil de PPC ou d aide inspiratoire avec PEP L H5i doit tre utilis uniquement en conformit avec les indications du m decin L H5i est pr vu pour un usage multiple par un seul patient domicile ou pour un usage multiple par plusieurs patients en milieu m dical Usage pr vu de l H5i for Her L utilisation de l H5i fo
31. cnicas do S9 Faixa de press o operacional Press o m xima de falha nica em estado est vel Toler ncia da medi o de press o Toler ncia da medi o de fluxo 4a 20 cm H20 30 cm H20 0 5 cm H 0 4 da leitura medida 6 I min ou 10 da leitura o que for maior VALORES DE EMISS O DE RU DO DE DOIS D GITOS DECLARADOS em conformidade com ISO 4871 N vel de press o ac stica N vel de pot ncia ac stica Dimens es nominais C x L x A Peso Constitui o do gabinete Oxig nio suplementar Filtro de ar hipoalerg nico Filtro de ar padr o Sa da de ar Especifica es t cnicas do H5i Temperatura m xima da chapa de aquecimento Temperatura de corte Temperatura m xima do g s Dimens es nominais C x L x A Peso reservat rio de gua Peso reservat rio de gua lav vel 24 dBA medida de acordo com ISO 17510 1 2002 26 dBA com margem de incerteza de 2 dBA medida segundo ISO 17510 1 2007 34 dBA com margem de incerteza de 2 dBA medida segundo ISO 17510 1 2007 153 x 140 x 86 mm 6 0 x 5 5 x 3 4 pol 835 g 1 8 lb Termopl stico de engenharia de retardador de chamas Fluxo de oxig nio suplementar m ximo recomendado 4 I min Fibras de polipropileno e acr licas n o entrela adas com substrato de polipropileno Fibra de poli ster A sa da de ar c nica de 22 mm encontra se em conformidade com ISO 5356 1 65 C 150 F 74 C 165 F lt 106 F lt 41 C Base de encaixe e reser
32. com descargas el tricas N o mergulhe o dispositivo S9 a base de encaixe do H5i a fonte de alimenta o nem o cabo de energia em gua Antes de limpar estes dispositivos sempre remova o plugue de energia da tomada e antes de reconect los certifique se de que est o secos Ao limpar o S9 o H5i ou o tubo de ar n o utilize solu es a base de alvejante cloro lcool ou subst ncias arom ticas nem sabonetes hidratantes ou bactericidas nem leos perfumados Esses produtos podem danificar e reduzir a vida til do equipamento Siga todas as precau es ao usar oxig nio suplementar Risco de explos o n o use na proximidade de anest sicos inflam veis Use somente fontes de alimenta o ResMed de 90W ou 30W Certifique se de que o cabo de energia e o plugue est o em boas condi es e que o equipamento n o se encontra danificado Mantenha o cabo de energia longe de superf cies quentes N o deixe cair nem insira nenhum objeto em aberturas ou tubos Nao deixe uma extens o de tubo de ar longa sobre a cabeceira da cama O tubo pode se enroscar em sua cabe a ou pesco o durante o sono 57 58 A AVISOS RELATIVOS AO S9 As orienta es contidas neste manual n o substituem as instru es prescritas pelo m dico N o utilize o S9 caso sejam observados defeitos externos bvios ou mudan as inexplic veis no desempenho Use somente tubos de ar e acess rios da ResMed com esses dispositivos A uti
33. comendados pela ResMed A conex o de outros tubos de fornecimento ou acess rios pode provocar les es no paciente ou danos ao dispositivo Deve se evitar a entrada de gua no dispositivo CPAP N o sobrecarregue o reservat rio de gua para evitar que a gua entre no dispositivo e no tubo de ar Tome cuidado ao manusear o H5i pois o reservat rio de gua ou a gua pode estar quente Deixe a chapa de aquecimento e a gua restante no reservat rio esfriarem por dez minutos 59 e A base de encaixe do H5i s deve ser conectada ou desconectada quando o reservat rio de gua estiver vazio Certifique se de que o reservat rio de gua est vazio antes de transportar o H5i N o utilize o H5i em aeronaves uma vez que pode ocorrer a entrada de gua no dispositivo CPAP e no tubo de ar durante turbul ncias Sempre coloque o H5i sobre uma superf cie plana abaixo do n vel do usu rio para evitar que a m scara e o tubo se encham de gua O Hb5i deve ser usado com cautela por pacientes que n o sejam capazes de remover a m scara sozinhos Se algum l quido for acidentalmente derramado sobre o H5i ou no interior de sua base de encaixe desconecte o dispositivo da tomada de energia Desconecte a base de encaixe do dispositivo CPAP e deixe a base drenar e secar antes de reutiliz la ZA AVISOS RELATIVOS AO TUBO DE AR e Caso uma eventual avaria no tubo provoque fuga de ar pare de usar o produto N o lave o tubo de
34. ctive sleep apnea OSA in patients weighing more than 66 Ib gt 30 kg The S9 Escape CPAP system is intended for home and hospital use S9 contraindications Positive airway pressure therapy may be contraindicated in some patients with the following pre existing conditions e severe bullous lung disease pneumothorax e pathologically low blood pressure e dehydration cerebrospinal fluid leak recent cranial surgery or trauma S9 adverse effects Patients should report unusual chest pain severe headache or increased breathlessness to their prescribing physician An acute upper respiratory tract infection may require temporary discontinuation of treatment The following side effects may arise during the course of therapy with these devices drying of the nose mouth or throat e nosebleed e bloating ear or sinus discomfort e eye irritation e skin rashes H5i indications for use The H5i is indicated for the humidification of the air delivered from a CPAP or bilevel device The H5i is for use only as recommended by a physician The H5i is intended for single patient re use in the home environment and re use in a hospital institutional environment H5i for Her indications for use The H5i for Her is indicated for the humidification of the air delivered from a CPAP or bilevel device The H5i is for use only as recommended by a physician The H5i for Her is intended for single patient re use in the home environment and r
35. deben ser efectuados nicamente por un agente de servicio autorizado de ResMed 4 42 Peligro de electrocuci n No sumerja el equipo S9 la estaci n de acoplamiento del H5i la fuente de alimentaci n ni el cable de alimentaci n en agua Siempre desenchufe los equipos antes de limpiarlos y aseg rese de que est n secos antes de enchufarlos nuevamente No utilice lej a cloro alcohol o soluciones arom ticas jabones hidratantes o antibacterianos ni aceites perfumados para limpiar el S9 el H5i o el tubo de aire Estas soluciones podr an causar da os y reducir la vida til de los productos Si utiliza ox geno suplementario tome todas las precauciones correspondientes Peligro de explosi n no lo utilice cerca de anest sicos inflamables Utilice solo las fuentes de alimentaci n ResMed de 90 W o 30 W Aseg rese de que el cable de alimentaci n y el enchufe est n en buenas condiciones y de que el equipo no est da ado Mantenga el cable de alimentaci n alejado de superficies calientes No deje caer ni inserte ning n objeto en los tubos o las aberturas No deje largos tramos del tubo de aire alrededor de la cabecera de la cama Podr an enroll rsele alrededor de la cabeza o el cuello mientras duerme ZN ADVERTENCIAS DEL S9 Las recomendaciones que figuran en el presente manual no deben sustituir las instrucciones del m dico tratante No utilice el S9 si presenta defectos externos obvios o si ocurren cambios inexplicabl
36. e a conect lo para reiniciar o dispositivo O umidificador aquecido H5i est com Pare de usar o H5i e contate seu m dico ou prestador de defeito servi os Exibe a mensagem de erro Falha de temperatura alta Consulte o manual do usu rio O dispositivo foi deixado em um Deixe esfriar antes de reutilizar Desconecte o cabo de ambiente quente energia e em seguida volte a conect lo para reiniciar o dispositivo 49 50 Problema possivel causa Solu o O filtro de ar est obstru do Substitua o filtro de ar Desconecte o cabo de energia e em seguida volte a conect lo para reiniciar o dispositivo O tubo de ar est obstru do Verifique o tubo de ar e remova eventuais obstru es Desconecte o cabo de energia e em seguida volte a conect lo para reiniciar o dispositivo A configura o do umidificador est Reduza a intensidade do umidificador e retire a gua do muita alta resultando em ac mulo de tubo de ar gua no tubo de ar Exibe a mensagem de erro Verifique a Fonte de Alimenta o 30 90W da ResMed e insira o conector totalmente O plugue CC foi inserido parcialmente Insira o plugue CC at o final ou muito lentamente na parte de tr s do dispositivo Uma fonte de alimenta o que n o da Remova a fonte de alimenta o e a substitua por uma da ResMed foi conectada ao dispositivo ResMed A roupa de cama est cobrindo a fonte Certifique se de que a fonte de alimenta o n o est de alimenta o
37. e use in a hospital institutional environment H5i contraindications The H5i is contraindicated for use with patients whose upper supraglottic airway has been bypassed Troubleshooting If there is a problem try the following suggestions If the problem cannot be solved contact your equipment supplier or ResMed Do not attempt to open these devices Problem possible cause Solution No display Power is not connected Ensure the power cable is connected and the power outlet if available is on The DC plug is partially inserted into the Fully insert the DC plug back of the device The S9 and H5i are not connected Ensure that the S9 and H5i are securely attached correctly Insufficient air delivered from the S9 device Ramp time is in use Wait for air pressure to build up or change ramp time Air filter is dirty Replace air filter Air tubing is not connected properly Check air tubing Air tubing is blocked pinched or Unblock or free the air tubing Check the air tubing for punctured punctures Mask and headgear are not positioned Adjust position of mask and headgear correctly The H6i flip lid is not latched correctly Close the flip lid ensuring that it clicks into place The H5i flip lid seal is not fitted correctly Make sure the flip lid seal is facing the right way up and fitted securely Incorrect air tubing selected If you are using the SlimLine or Standard air tubing ensure that you have the correct air tubing
38. e ventila o incluindo fontes de 2 anos alimenta o externas e Acess rios de baterias e Dispositivos port teis para diagn stico ou triagem e Umidificadores Esta garantia s est dispon vel para o consumidor inicial N o transfer vel Se o produto apresentar defeito em condi es normais de utiliza o a ResMed efetuar a seu crit rio o reparo ou a substitui o do produto defeituoso ou de qualquer um de seus componentes Esta garantia limitada n o cobre a danos causados como resultado do uso inadequado abuso modifica o ou altera o do produto b consertos realizados por quaisquer provedores de servi o que n o estejam expressamente autorizados pela ResMed e c quaisquer danos ou contamina o causados por fuma a de cigarro cachimbo charuto ou de outro tipo A garantia deixar de ser v lida se o produto for vendido ou revendido fora da regi o de compra original Os pedidos de reparo ou substitui o de um produto defeituoso no mbito da garantia devem ser feitos pelo consumidor original no local de compra Esta garantia substitui todas as outras expl citas ou impl citas incluindo qualquer garantia impl cita de comercializa o ou de adequabilidade para determinado fim Algumas regi es ou estados n o permitem limita es de tempo sobre a dura o de uma garantia impl cita pelo que a limita o acima pode n o se aplicar ao seu caso A ResMed n o se responsabiliza por quaisquer da
39. eLineMAX is designed only for use with the H5i Usage pr vu de la S9 AutoSet La S9 AutoSet est appareil autopilot pr vu pour le traitement du syndrome d apn es obstructives du sommeil SAOS chez les patients de plus de 30 kg 66 Ib La S9 AutoSet est appareil autopilot pr vu pour une utilisation a domicile ou en milieu m dical Usage pr vu de la S9 AutoSet for Her La S9 AutoSet for Her est appareil autopilot pr vu pour le traitement du syndrome d apn es obstructives du sommeil SAOS chez les patients de plus de 30 kg 66 Ib La S9 AutoSet for Her est appareil autopilot pr vu pour une utilisation domicile ou en milieu m dical Usage pr vu de la S9 Elite La S9 Elite est pr vue pour le traitement du syndrome d apn es obstructives du sommeil SAOS par PPC chez les patients de plus de 30 kg 66 Ib La S9 Elite est pr vue pour une utilisation domicile ou en milieu m dical Usage pr vu de la S9 Escape Auto La S9 Escape Auto est un appareil autopilot pr vu pour le traitement du syndrome d apn es obstructives du sommeil SAOS pesant plus de 30 kg 66 lb La S9 Escape Auto est pr vue pour une utilisation domicile ou en milieu m dical Usage pr vu de la S9 Escape La S9 Escape est un appareil de pression positive continue PPC pr vu pour les patients trait s contre le syndrome d apn es obstructives du sommeil SAOS pesant plus de 30 kg 66 lb La S9 Escape est pr vue pour une utilisation a domi
40. el aire fluya permanentemente hacia fuera de ellas Cuando el dispositivo est encendido y funcionando correctamente el aire fresco que este proporciona hace que el aire espirado salga de la mascarilla a trav s de los orificios de ventilaci n No obstante cuando el dispositivo no est funcionando no se suministrar suficiente aire fresco a trav s de la mascarilla y es posible que se vuelva a respirar el aire exhalado Volver a respirar aire exhalado durante varios minutos puede en algunas circunstancias provocar asfixia Esto se aplica a la mayor a de los modelos de equipos CPAP Si se produce un corte de energ a o si el equipo est funcionando mal quitese la mascarilla Estos equipos S9 pueden configurarse para suministrar presiones de hasta 20 cm de H50 En el caso improbable de que se produzcan ciertas condiciones que causen fallas en el funcionamiento las presiones pueden alcanzar hasta 30 cm de H20 Cuando el equipo CPAP no est funcionando el flujo de ox geno debe desconectarse para evitar que el ox geno no utilizado se acumule dentro del equipo lo que constituir a riesgo de incendio El ox geno favorece la combusti n Por lo tanto el ox geno no debe utilizarse en presencia de una llama expuesta o si hay un cigarrillo encendido es Es posible incorporar puertos en la mascarilla o en los conectores pr ximos a la mascarilla 2 Durante los cortes de energ a parciales por debajo del voltaje nominal m nimo o totale
41. el nivel de Ilenado de la cubeta de agua Se forma condensaci n en el tubo de aire y en la mascarilla Fuga en la cubeta de agua La cubeta de agua puede estar da ada O agrietada La cubeta de agua lavable no est conectada correctamente Soluci n Verifique que el nivel de agua est por debajo de la marca de nivel m ximo Baje la configuraci n del H5i o de la humedad relativa a trav s del men Comun quese con su proveedor de servicio para efectuar el cambio Verifique que la cubeta de agua no est da ada y vuelva a conectarla correctamente En la mascarilla el aire se siente muy caliente o fr o La temperatura del tubo de aire del ClimateLine o del ClimateLineMAX est demasiado alta o baja Especificaciones t cnicas generales Fuente de alimentaci n de 90 W Fuente de alimentaci n de 30 W Temperatura de funcionamiento Humedad de funcionamiento Altitud de funcionamiento Temperatura de almacenamiento y transporte Humedad de almacenamiento y transporte Aumente o reduzca la temperatura del tubo t rmico a rav s del men L mites de entrada 100 a 240 V 50 a 60 Hz nominal para uso en aviones 110 V 400 Hz Consumo de potencia habitual 70 W 80 VA ximo consumo de potencia 110 W 120 VA L mites de entrada 100 a 240 V 50 a 60 Hz nominal para uso en aviones 110 V 400 Hz Consumo de potencia habitual 20 W 30 VA ximo consumo de potencia 36 W 75 VA De 5 C a 35 C 41 F a
42. en must not be used while smoking or in the presence of an open flame 9 CAUTIONS Be careful not to place your device where it can be bumped or where someone is likely to trip over he power cord f you put the device on the floor make sure the area is free from dust and clear of bedding clothes or other objects that could block the air inlet or cover the power supply unit Make sure the area around the device is dry and clean Do not hang the air tubing in direct sunlight as it may harden over time and eventually crack Do not wash the air filter The air filter is not washable or reusable The air filter cover protects the device in the event of accidental liquid spillage Ensure the air filter and air filter cover are fitted at all times At low pressures the flow through the exhalation ports of your mask may not clear all exhaled gas rom the tubing Some rebreathing may occur The airflow for breathing produced by these devices can be as much as 11 F 6 C higher than the temperature of the room Caution should be exercised if the room temperature is warmer than 90 F 32 C H5i WARNINGS The H5i is designed only for use with S9 Series devices Do not use the H5i with any other CPAP device Do not operate the H5i if it is not working properly or if any part of the CPAP device or H5i has been dropped or damaged The H5i should only be used with tubing or accessories recommended by ResMed Connection of other delivery tu
43. es de fonctionnement Le produit est conforme toutes les exigences de compatibilit lectromagn tique CEM applicables conform ment CEI 60601 1 2 pour les environnements commerciaux et r sidentiels et pour l industrie l g re Vous trouverez des informations sur les missions et limmunit lectromagn tiques pour ces appareils ResMed sur le site www resmed com la page Produits sous la rubrique Service et assistance Une fois sur cette page cliquer sur le fichier PDF dans votre langue de pr f rence ResMed confirme que la s rie S9 r pond aux exigences RTCA DO 160F de la Federal Aviation Administration FAA pour toutes les phases des voyages par avion Classe Il double isolation type BF De 4 20 cm de H20 30 cm H20 Tol rance pour la mesure de la pression 0 5 cm H50 4 de la valeur mesur e Tol rance pour la mesure du d bit 6 I min ou 10 de la valeur le plus lev des deux VALEURS D MISSION SONORE DEUX CHIFFRES D CLAR ES conform ment la norme ISO 4871 Niveau de pression acoustique Niveau de puissance acoustique Dimensions nominales L x x H Poids Boitier Oxyg ne suppl mentaire Filtre a air hypoallerg nique 24 dBA mesure effectu e conform ment a ISO 17510 1 2002 26 dBA avec une incertitude de 2 dBA mesure effectu e conform ment ISO 17510 1 2007 34 dBA avec une incertitude de 2 dBA mesure effectu e conform ment ISO 17510 1 2007
44. es en su funcionamiento Solo deben usarse tubos de aire y accesorios ResMed con estos equipos Un tubo de aire o accesorio de otro tipo puede modificar la presi n que usted efectivamente recibe y ello reducir a la eficacia del tratamiento Obstruir el tubo o la entrada de aire mientras el equipo S9 est funcionando podr a provocar un sobrecalentamiento Si el m dico le ha indicado que use la tarjeta SD para actualizar la configuraci n de su dispositivo y el mensaje Configuraci n actualizada no aparece comun quese inmediatamente con l El paciente no debe conectar ning n dispositivo en el puerto del conector del m dulo a menos que su m dico o proveedor de atenci n m dica as se lo indique nicamente los productos ResMed han sido dise ados para conectarse al puerto del conector del m dulo Conectar otros dispositivos puede provocar lesiones a personas o da os al equipo S9 Estos equipos 9 deben utilizarse nicamente con las mascarillas y conectores recomendados por ResMed o por un m dico o terapeuta respiratorio No utilice la mascarilla a menos que el dispositivo est encendido Una vez que se haya colocado la mascarilla compruebe que el dispositivo est generando un flujo de aire Nunca se debe obstruir el o los orificios de ventilaci n asociados con la mascarilla Explicaci n El equipo S9 est dise ado para utilizarse con mascarillas o conectores especiales que tienen orificios de ventilaci n para que
45. espiratoires et accessoires recommand s par ResMed Le raccordement d autres circuits respiratoires ou accessoires peut entra ner des blessures ou endommager l appareil Les mesures n cessaires devront tre prises pour emp cher que de l eau ne puisse s couler dans l appareil de PPC Ne pas trop remplir le r servoir sans quoi de l eau risque de s couler dans l appareil et dans le circuit respiratoire Manipulez l H5i avec pr caution dans la mesure o l eau et le r servoir risquent d tre chauds Laisser la plaque chauffante et l eau r siduelle ventuelle refroidir pendant 10 minutes Le support de l H5i doit tre mis en place ou retir uniquement lorsque le r servoir est vide V rifiez que le r servoir est vide avant de transporter l H5i Ne pas utiliser l H5i dans un avion dans la mesure o de l eau risque de s couler dans l appareil de PPC et dans le circuit respiratoire en cas de turbulences Toujours placer l H5i sur une surface plane un niveau inf rieur celui du patient afin d viter tout coulement d eau dans le masque et le circuit respiratoire L H5i doit tre utilis avec pr caution si le patient n est pas en mesure d enlever le masque lui m me En cas de d versement accidentel de liquides dans ou sur la station d accueil de H5i d branchez l appareil de la prise de courant D tachez la station d accueil de l appareil de PPC et laissez la se vider et s cher avant de la r utiliser A AVERTISSEME
46. external power supply units 2 years e Battery accessories e Portable diagnostic screening devices e Humidifiers This warranty is only available to the initial consumer It is not transferable If the product fails under conditions of normal use ResMed will repair or replace at its option the defective product or any of its components This limited warranty does not cover a any damage caused as a result of improper use abuse modification or alteration of the product b repairs carried out by any service organization that has not been expressly authorized by ResMed to perform such repairs and c any damage or contamination due to cigarette pipe cigar or other smoke Warranty is void on product sold or resold outside the region of original purchase Warranty claims on defective product must be made by the initial consumer at the point of purchase This warranty replaces all other expressed or implied warranties including any implied warranty of merchantability or fitness for a particular purpose Some regions or states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you ResMed shall not be responsible for any incidental or consequential damages claimed to have resulted from the sale installation or use of any ResMed product Some regions or states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation may not apply to you Thi
47. iental es superior a 32 C 90 F ZA ADVERTENCIAS DEL H5i El H5i est dise ado solo para uso con los equipos de la serie S9 No use el H5i con ning n otro equipo CPAP No utilice el H5i si no funciona adecuadamente o si alguna pieza del equipo CPAP o del H5i se ha ca do o est da ada El H5i solo debe utilizarse con tubos o accesorios recomendados por ResMed Conectarlo a otros accesorios o tubos de suministro podr a provocar una lesi n o da ar el dispositivo Debe evitar que entre agua en su equipo CPAP No sobrepase el nivel m ximo de llenado de la cubeta ya que el agua podr a ingresar al dispositivo y al tubo de aire Tenga cuidado al manipular el H5i ya que el agua o la cubeta de agua puede estar caliente Espere 10 minutos para que la placa de calefacci n y el agua que haya quedado se enfr en La estaci n de acoplamiento del H5i solo debe conectarse o desconectarse cuando la cubeta de agua est vac a Aseg rese de que la cubeta de agua est vac a antes de transportar el H5i No utilice el H5i en un avi n ya que el agua podr a entrar al equipo CPAP o al tubo de aire durante una turbulencia Siempre coloque el H5i en una superficie nivelada que se encuentre m s abajo que el usuario para evitar que la mascarilla y el tubo se llenen de agua El H5i debe utilizarse con precauci n en pacientes que no puedan retirarse la mascarilla por sus propios medios Encaso de que inadvertidamente se derramen l quido
48. ill correctement Le joint d tanch it du couvercle rabattable de H5i n est pas ajust correctement Le circuit respiratoire s lectionn n est pas le bon Attendez que la pression augmente ou modifiez la dur e de rampe Remplacez le filtre air V rifiez le circuit respiratoire D bouchez ou d gagez le circuit respiratoire V rifiez que le circuit respiratoire n est pas perc Ajustez la position du masque et du harnais Fermez le couvercle rabattable en vous assurant qu il se verrouille en position V rifiez que le joint du couvercle rabattable est dans le bon sens et correctement mis en place Si vous utilisez un circuit respiratoire SlimLine ou Standard veillez s lectionner le bon circuit respiratoire dans le menu L appareil ne d marre pas lorsque vous respirez dans le masque La respiration n est pas assez profonde pour d clencher SmartStart Stop Ily a une fuite excessive La fonction SmartStart Stop est d sactiv e Remarque SmartStart Stop n est pas disponible sur S9 Escape et S9 Escape Auto Respirez et expirez profond ment dans le masque Ajustez la position du masque et du harnais Le circuit respiratoire n est pas correctement raccord Connectez fermement les deux extr mit s Activez SmartStart Stop 17 18 Probl me cause possible Solution L appareil ne s arr te pas lorsque vous retirez votre masque La fonction SmartStart Stop est Activez SmartStart S
49. l m ximo 380 ml Termopl stico de ingenier a ign fuga aluminio Pl stico moldeado por inyecci n acero inoxidable y junta de silicona Pl stico moldeado por inyecci n aluminio y elast mero termopl stico Especificaciones t cnicas del tubo de aire Tubo de aire t rmico ClimateLine Tubo de aire t rmico ClimateLine MAX Tubo de aire SlimLine Tubo de aire est ndar Temperatura de desconexi n de la manguera t rmica Pl stico flexible y componentes el ctricos 2 m 6 6 15 mm de di metro interno Pl stico flexible y componentes el ctricos 1 9 m 6 3 19 mm de di metro interno stico flexible 1 8 m 6 di metro interno de 15 mm stico flexible 2 m 6 6 di metro interno de 19 mm lt 106 F lt 41 C P P Notas El fabricante se reserva el derecho de modificar las presentes especificaciones sin previo aviso e Las configuraciones de temperatura y de humedad relativa para el ClimateLine o el ClimateLineMAX que aparecen en pantalla no son valores medidos Consulte al m dico o al proveedor de servicio antes de utilizar el tubo de aire SlimLine con equipos que no sean el S9 o el H5i Rendimiento del humidificador Las siguientes configuraciones han sido probadas a una temperatura ambiental de 22 C Presi n CPAP de salida de HR AH nominal de salida del sistema en la mascarilla BTPS cm de H20 Valor 3 Valor 6 Valor 3 Valor 6 4 90 100 10 18 10 95 100 11 5 21 20 95 100 11 1
50. les rebrancher Ne pas utiliser d eau de Javel de chlore d alcool ou de solutions parfum es y compris les huiles parfum es ni de savons hydratants ou antibact riens pour le nettoyage de la S9 de l H5i ou du circuit respiratoire Ces produits risquent d endommager les appareils et de r duire leur dur e de vie Prenez toutes les pr cautions applicables lors de l adjonction d oxyg ne Risque d explosion Ne pas utiliser l appareil proximit d anesth siques inflammables Utilisez uniquement les modules d alimentation ResMed de 90 W ou de 30 W V rifiez que le c ble d alimentation et la fiche sont en bon tat et que l quipement n est pas endommag Tenir le c ble d alimentation l cart de toute surface chaude Ne pas laisser tomber ni ins rer d objet dans les ouvertures ou les tuyaux Ne pas laisser de longueurs inutiles de tuyau en haut du lit Elles pourraient s enrouler autour de votre t te ou de votre cou pendant que vous dormez A AVERTISSEMENTS CONCERNANT LES S9 Les conseils donn s dans ce guide ne remplacent pas les instructions du m decin traitant Ne pas utiliser la S9 en cas de d fauts externes vidents ou si sa performance devient al atoire Seuls le circuit respiratoire et les accessoires ResMed peuvent tre utilis s avec ces appareils Les circuits respiratoires et accessoires d un autre type risquent de modifier la pression re ue et de r duire l efficacit de votre traitement Lobstruction du
51. liza o de tipos de tubo de ar ou acess rios diferentes pode alterar a press o de fato recebida reduzindo assim a efic cia do tratamento A obstru o do tubo de ar e ou da entrada de ar do dispositivo S9 durante seu funcionamento pode acarretar o superaquecimento do aparelho Se o m dico tiver pedido a voc para usar o cart o SD para atualizar as configura es no seu dispositivo e a mensagem Configura es atualizadas com xito n o for apresentada contate o m dico imediatamente O paciente n o deve conectar nenhum dispositivo porta de conex o do m dulo a menos que tenha recebido instru es para isso do prestador de cuidados de sa de ou do m dico Somente produtos ResMed s o projetados para serem conectados porta de conex o do m dulo A conex o de outros dispositivos pode provocar les es ou danificar o dispositivo S9 Os dispositivos S9 s devem ser usados com m scaras e conectores recomendados pela ResMed ou por um m dico ou terapeuta respirat rio A m scara s deve ser usada se o dispositivo estiver ligado Depois que a m scara for ajustada certifique se de que o dispositivo est ventilando ar Os respiradouros associados m scara nunca devem ser obstru dos Explica o Seu S9 foi projetado para uso com m scaras ou conectores especiais que possuam respiradouros para permitir que o ar flua continuamente para fora da m scara Quando o dispositivo estiver ligado e funcionando corretamente
52. ma de ajuste autom tico S9 Escape Auto est dise ado para uso hospitalario y domiciliario Indicaciones de uso del S9 Escape El sistema de presi n positiva y continua en las v as respiratorias CPAP S9 Escape est indicado para el tratamiento de la apnea obstructiva del sue o AOS en pacientes que pesan m s de 30 kg 66 Ib El sistema CPAP S9 Escape est dise ado para uso hospitalario y domiciliario Contraindicaciones del S9 El tratamiento con presi n positiva en las v as respiratorias puede estar contraindicado en algunos pacientes que presenten las siguientes afecciones previas enfermedad pulmonar bullosa grave neumot rax presi n arterial patol gicamente baja e deshidrataci n e fuga de l quido cefalorraqu deo cirug a craneal reciente o traumatismo Efectos secundarios del S9 Los pacientes deben informar a su m dico tratante si tienen alg n dolor inusual en el pecho dolor de cabeza grave o m s dificultad para respirar Una infecci n aguda en las v as respiratorias superiores puede requerir la suspensi n temporal del tratamiento Durante el curso del tratamiento con estos equipos pueden aparecer los siguientes efectos colaterales e resequedad de la nariz boca o garganta e epistaxis e hinchaz n e molestias sinusales o del o do e irritaci n ocular e erupciones cut neas Indicaciones de uso del H5i El H5i est indicado para la humidificaci n del aire que se suministra desde un disp
53. mateLine air ubing tubing and contact your clinician service provider Use Standard or SlimLine tubing in the interim Displays error message Humidifier fault replace humidifier Device has been left in a hot Allow to cool before re use Disconnect the power cord environment and then reconnect it to restart the device There is a fault in your H5i heated Discontinue using your H5i and contact your clinician humidifier service provider Problem possible cause Solution Displays error message High temperature fault refer to user manual Device has been left in a hot Allow to cool before re use Disconnect the power cord environment and then reconnect it to restart the device Air filter is blocked Replace your air filter Disconnect the power cord and then reconnect it to restart the device Air tubing is blocked Check your air tubing and remove any blockages Disconnect the power cord and then reconnect it to restart the device Humidifier setting is too high resulting Turn the humidifier setting down and empty the water from in accumulation of water in the air the air tubing tubing Displays error message Check ResMed 30 90W Power Supply Unit and fully insert the connector The DC plug is partially inserted into the Fully insert the DC plug back of the device or inserted too slowly A non ResMed power supply unit is Remove the power supply unit and replace with a ResMed connected to the device power supply
54. nesa 2 Manuten o Os dispositivos S9 e H5i s o indicados para fornecer um funcionamento seguro e confi vel quando operados de acordo com as instru es fornecidas pela ResMed Caso haja algum sinal de desgaste ou alguma preocupa o com o funcionamento do dispositivo a ResMed recomenda que o S9 e o H5i sejam examinados e consertados por uma Assist ncia T cnica autorizada da ResMed Caso contr rio n o deve haver necessidade de conserto ou verifica o do dispositivo durante sua vida til projetada de cinco anos 55 56 Garantia limitada A ResMed Ltd doravante ResMed oferece garantia contra quaisquer defeitos de fabrica o material e m o de obra pelo per odo de tempo abaixo especificado a partir da data de compra Per odo da Produto garantia e Sistemas de m scara incluindo arma o almofada arn s e tubo exceto 90 dias dispositivos de uso nico e Acess rios exceto dispositivos de uso nico e Sensores de pulso do dedo do tipo flex vel e Reservat rios de gua do umidificador e Baterias para uso em sistemas de bateria internos e externos da ResMed 6 meses e Sensores de pulso do dedo com presilha 1 ano dulos de dados dos dispositivos CPAP e de dois n veis e Ox metros e adaptadores de oximetro para dispositivos CPAP e de dois n veis e Reservat rios de gua lav veis para umidificadores e Dispositivos de controle de titula o e Dispositivos CPAP de dois n veis e d
55. nos incidentais ou consequenciais alegadamente ocorridos em decorr ncia da venda instala o ou do uso de qualquer produto ResMed Algumas regi es ou estados n o permitem a exclus o ou a limita o de danos incidentais ou consequenciais Sendo assim a limita o acima pode n o se aplicar ao seu caso Esta garantia lhe concede direitos legais espec ficos e voc pode ainda ter outros direitos que variam de acordo com a regi o Para mais informa es sobre seus direitos de garantia entre em contato com o revendedor local ou os escrit rios da ResMed A AVISOS GERAIS Leia todo o manual antes de utilizar estes dispositivos e Nos EUA a lei federal limita a venda destes dispositivos a m dicos ou por ordem destes Siga sempre o uso previsto para estes dispositivos conforme descri o neste manual Siga corretamente as instru es de seu m dico ou prestador de cuidados sa de Se voc perceber quaisquer altera es inexplic veis no desempenho deste aparelho se ele estiver emitindo sons incomuns ou fortes se o aparelho ou a fonte de alimenta o forem derrubados ou mal utilizados se caiu gua no gabinete ou se o gabinete estiver quebrado interrompa o uso e entre em contato com o Centro de Servi os da ResMed N oabrao S9 ou o H5i N o existem pe as dentro do aparelho que possam ser reparadas pelo usu rio A manuten o e os reparos s devem ser realizados por t cnicos autorizados pela ResMed Tome cuidado
56. o ar renovado do dispositivo elimina o ar expirado na m scara atrav s dos respiradouros Contudo quando o dispositivo n o est funcionando n o fornecido ar renovado suficiente atrav s da m scara e o ar expirado pode ser novamente reinalado A inala o por mais de alguns minutos do ar expirado pode em certos casos provocar asfixia Isso se aplica maioria dos modelos de dispositivos CPAP Em caso de falta de energia ou defeito no aparelho remova a m scara Estes dispositivos S9 podem ser ajustados para administrar press es de at 20 cm H20 No caso improv vel de certas condi es de avaria poss vel a administra o de press es de at 30 cm H 0 ga Portas podem ser incorporadas m scara ou a conectores que estejam pr ximos da m scara 2 Durante uma falha parcial abaixo da tens o nominal m nima ou total no fornecimento de energia as press es terap uticas n o ser o fornecidas Quando a energia for restaurada a opera o ser reiniciada sem altera es de configura o O fluxo de oxig nio deve ser desligado quando o dispositivo CPAP nao estiver funcionando para que o oxig nio n o utilizado n o se acumule no gabinete do dispositivo gerando risco de inc ndio O oxig nio favorece a combust o N o use oxig nio quando estiver fumando nem em presen a de chamas desguarnecidas ZA PRECAU ES COM O s9 Tome cuidado para n o colocar o dispositivo em local onde possa ser derrubado ou seja
57. o voc remove a m scara O SmartStart Stop est desativado Observa o O SmartStart Stop n o est dispon vel no S9 Escape e S9 Escape Auto Ative o SmartStart Stop Problema possivel causa Solu o O SmartStart Stop encontra se ativado mas o dispositivo n o para automaticamente quando voc remove a m scara Sistema de m scara incompat vel Use somente equipamento recomendado pela ResMed em uso O paciente est usando uma m scara Desative o SmartStart Stop de almofadas nasais com press o fixa inferior a 7 cm H 0 A press o aumenta de modo impr prio Fala tosse ou respira o irregular Evite falar quando estiver usando uma m scara nasal e respire de maneira normal A almofada da m scara est vibrando Ajuste o arn s sobre a pele Exibe a mensagem de erro Falha no tubo aquecido Substitua o tubo O dispositivo foi deixado em um Deixe esfriar antes de reutilizar Desconecte o cabo de ambiente quente energia e em seguida volte a conect lo para reiniciar o dispositivo H um defeito no seu tubo de ar Interrompa o uso do tubo de ar ClimateLine ou ClimateLine ou ClimateLineMAX ClimateLineM2X e contate o seu m dico ou prestador de servi os Nesse intervalo utilize o tubo Standard ou SlimLine Exibe a mensagem de erro Falha no umidificador Substitua o umidificador O dispositivo foi deixado em um Deixe esfriar antes de reutilizar Desconecte o cabo de ambiente quente energia e em seguida volt
58. onectados de correctamente manera segura 31 32 Problema Causa posible Soluci n El equipo S9 no proporciona suficiente aire Se est usando el per odo de rampa El filtro de aire est sucio El tubo de aire no est debidamente conectado El tubo de aire est obstruido apretado o perforado La mascarilla y el dispositivo para la cabeza no est n correctamente colocados La tapa del H5i no est trabada correctamente El sello de la tapa del H5i no est colocado correctamente Selecci n incorrecta del tubo de aire Espere a que la presi n de aire aumente o modifique el per odo de rampa Cambie el filtro de aire Revise el tubo de aire Elimine la obstrucci n o libere el tubo de aire Verifique que el tubo de aire no est perforado Ajuste la posici n de la mascarilla y el dispositivo para la cabeza Cierre la tapa asegur ndose de que encaje en su lugar Aseg rese de que el sello de la tapa est colocado al derecho y bien asegurado Si est utilizando los tubos de aire SlimLine o Est ndar asegurese de que en el men haya seleccionado el tipo de tubo de aire correcto El dispositivo no se pone en marcha cuando usted respira en la mascarilla La respiraci n no es lo suficientemente profunda para activar la funci n SmartStart Stop Hay una fuga excesiva La funci n SmartStart Stop est desactivada Nota El SmartStart Stop no est disponible en el S9 Escape ni en el S
59. ormalement pas tre requises au cours des cinq ann es de vie utile de ces appareils Garantie limit e ResMed Ltd d sign e ci apr s ResMed garantit votre produit ResMed contre tout d faut de mat riaux et de main d uvre pour la p riode sp cifi e ci apr s compter de la date d achat Produit Masques y compris cadre bulle harnais et circuit respiratoire dispositifs usage unique exclus Accessoires dispositifs usage unique exclus Capteurs digitaux de pouls flexibles R servoirs d eau d humidificateur Dur e de la garantie 90 jours Batteries utiliser dans les syst mes de batteries externes et internes ResMed 6 mois Capteurs digitaux de pouls de type clip Modules de transmission de donn es pour appareil de PPC ou d aide inspiratoire avec PEP Oxym tres et adaptateurs d oxym tre pour appareil de PPC ou d aide inspiratoire avec PEP R servoirs d eau nettoyables pour humidificateur Appareils de commande de la titration Appareils de PPC d aide inspiratoire avec PEP et de ventilation y compris les modules d alimentation externes Accessoires de batteries Dispositifs portables de diagnostic et d pistage Humidificateurs 2 ans Seul le client initial est couvert par la pr sente garantie Elle n est pas cessible En cas de d faillance du produit dans des conditions normales d utilisation ResMed son enti re discr tion r pare ou remplace le produit d fec
60. ositivo CPAP o binivel El H5i solo debe ser utilizado por recomendaci n m dica El H5i est dise ado para ser utilizado en repetidas ocasiones por un nico paciente en el domicilio y para ser utilizado en repetidas ocasiones en hospitales o instituciones Indicaciones de uso del H5i for Her El H5i for Her est indicado para la humidificaci n del aire que se suministra desde un dispositivo CPAP o binivel El H5i for Her solo debe ser utilizado por recomendaci n m dica El H5i for Her est dise ado para ser utilizado en repetidas ocasiones por un nico paciente en el domicilio y para ser utilizado en repetidas ocasiones en hospitales o instituciones Contraindicaciones del H5i El H5i est contraindicado en pacientes que no respiran por las v as respiratorias superiores supragl ticas Soluci n de problemas Si surge alg n problema intente poner en pr ctica las sugerencias que figuran a continuaci n Si el problema no se puede resolver comun quese con el proveedor del equipo o con ResMed No intente abrir estos equipos Problema Causa posible Soluci n Pantalla en blanco La alimentaci n no est conectada Verifique que el cable de alimentaci n est conectado y que el tomacorriente en caso de haberlo est encendido El enchufe de CC est insertado Inserte el enchufe de CC completamente parcialmente en la parte posterior del equipo EI S9 y el H5i no est n conectados Aseg rese de que el S9 y el H5i est n c
61. ould result in injury or damage to the S9 device These S9 devices should only be used with masks and connectors recommended by ResMed or by a physician or respiratory therapist A mask should not be used unless the device is turned on Once the mask is fitted ensure that the device is blowing air The vent hole or holes associated with the mask should never be blocked Explanation Your S9 is intended to be used with special masks or connectors which have vent holes to allow continuous flow of air out of the mask When the device is turned on and functioning properly new air from the device flushes the exhaled air out through the mask vent holes However when the device is not operating insufficient fresh air will be provided through the mask and the exhaled air may be rebreathed Rebreathing of exhaled air for longer than several minutes can in some circumstances lead to suffocation This applies to most models of CPAP devices 1 Ports may be incorporated into the mask or in connectors that are near the mask In the event of power failure or machine malfunction remove the mask These S9 devices can be set to deliver pressures up to 20 cm H50 In the unlikely event of certain fault conditions pressures up to 30 cm H20 are possible Oxygen flow must be turned off when the CPAP device is not operating so that unused oxygen does not accumulate within the device enclosure and create a risk of fire Oxygen supports combustion Oxyg
62. poss vel trope ar no cabo de energia Se colocar o aparelho no ch o certifique se de que a rea n o est empoeirada e n o cont m roupa de cama pe as de vestu rio ou outros itens que possam obstruir a entrada de ar ou cobrir a fonte de alimenta o Certifique se de que a rea volta do dispositivo se encontra limpa e seca N o deixe o tubo de ar dependurado sob luz solar direta pois o material poder enrijecer com o tempo e rachar N o lave o filtro de ar O filtro de ar n o lav vel nem reutilizavel A tampa do filtro de ar protege o dispositivo caso algum l quido seja acidentalmente derramado sobre ele Certifique se de que o filtro de ar e a tampa do filtro de ar estejam sempre instalados Sob baixas press es o fluxo atrav s das portas de exala o da m scara poder n o eliminar todo o g s expirado do tubo Poder ocorrer alguma reinala o O fluxo de ar para respirar produzido por estes dispositvos pode chegar a uma temperatura de at 6 C 11 F acima da temperatura ambiente Tome cuidado no caso de a temperatura ambiente estar acima de 32 C 90 F ZA AVISOS RELATIVOS AO H5i O H5i foi projetado para uso somente com dispositivos da Linha S9 N o use o H5i com nenhum outro dispositivo CPAP N o opere o H5i caso o aparelho n o esteja funcionando corretamente ou se alguma pe a do dispositivo CPAP ou do Hi tiver ca do ou sofrido danos O H5i deve ser utilizado somente com tubos ou acess rios re
63. power consumption 70W 80VA Maximum power consumption 110W 120VA Input range 100 240V 50 60Hz Nominal for aircraft use 110V 400Hz Typical power consumption 20W 30VA Maximum power consumption 36W 75VA 41 F to 95 F 5 C to 35 C 10 95 non condensing Sea level to 8 500 2 591 m 4 F to 140 F 20 C to 60 C 10 95 non condensing Product complies with all applicable electromagnetic compatibility requirements EMC according to IEC60601 1 2 for residential commercial and light industry environments Information regarding the electromagnetic emissions and immunity of these ResMed devices can be found on www resmed com on the Products page under Service and Support Click on the PDF file for your language ResMed confirms that the S9 Series meets the Federal Aviation Administration FAA requirements RTCA DO 160F for all phases of air travel Class II double insulation Type BF 4 to 20 cm H20 30 cm H 0 0 5 cm H20 4 of the measured reading 6 L min or 10 of reading whichever is greater DECLARED DUALNUMBER NOISE EMISSION VALUES in accordance with ISO 4871 Sound pressure level Sound power level Nominal dimensions L x W x H Weight Housing construction Supplemental oxygen Hypoallergenic air filter Standard air filter Air outlet H5i technical specifications Maximum heater plate temperature Temperature cut out Maximum gas temperature Nominal dimensions L x W x H Weight
64. r D branchez le environnement chaud cable d alimentation et rebranchez le ensuite pour red marrer l appareil Probl me cause possible Solution Une erreur est survenue dans votre N utilisez plus votre H5i et contactez votre clinicien ou humidificateur chauffant H5i votre fournisseur Affichage du message d erreur Erreur de temp rature lev e consultez le manuel de l utilisateur L appareil a t laiss dans un Laissez le refroidir avant de le r utiliser D branchez le environnement chaud c ble d alimentation et rebranchez le ensuite pour red marrer l appareil Le filtre air est obstru Remplacez le filtre air D branchez le c ble d alimentation et rebranchez le ensuite pour red marrer l appareil Le circuit respiratoire est obstru V rifiez le circuit respiratoire et retirez tout l ment qui l obstrue D branchez le c ble d alimentation et rebranchez le ensuite pour red marrer l appareil Le r glage de l humidificateur est trop Mettez le bouton de r glage de l humidificateur sur une lev causant l accumulation d eau dans valeur moins lev e et videz le circuit respiratoire le circuit respiratoire Affichage du message d erreur V rifiez le module d alimentation 30 90 W ResMed et ins rez le raccord fond La fiche CC est mal ins r e l arri re de Ins rez la fiche CC fond l appareil ou a t enfonc e trop lentement Un module d alimentation d une autre Retirez le module
65. r Her est indiqu e pour l humidification de l air d livr par un appareil de PPC ou d aide inspiratoire avec PEP L H5i for Her doit tre utilis uniquement en conformit avec les indications du m decin LH5i for Her est pr vu pour un usage multiple par un seul patient domicile ou pour un usage multiple par plusieurs patients en milieu m dical Contre indications concernant l humidificateur H5i L utilisation de l H5i est contre indiqu e chez les patients trach otomis s ou intub s D pannage En cas de probl me reportez vous aux suggestions suivantes Si le probl me ne peut tre r solu contactez votre fournisseur de mat riel ou ResMed Ne tentez pas d ouvrir ces appareils Probl me cause possible Solution Aucun affichage L alimentation n est pas connect e Assurez vous que le c ble d alimentation est connect et que la prise de courant si disponible est ouverte La fiche CC est mal ins r e l arri re Ins rez la fiche CC fond de l appareil LH5i n est pas correctement fix V rifiez que la S9 et l H5i sont bien branch s la S9 Probl me cause possible Solution Le d bit d air d livr par la S9 est insuffisant La dur e de rampe est activ e Le filtre a air est sale Le circuit respiratoire n est pas correctement raccord Le circuit respiratoire est obstru pinc ou perc Le masque et le harnais sont mal mis en place Le couvercle rabattable de I H5i n est pas verrou
66. r la carte SD et communiquer avec votre fournisseur La carte SD n est pas correctement V rifiez que la carte SD est bien ins r e ins r e Vous avez peut tre retir la carte SD Ins rez nouveau la carte SD et attendez que l cran avant que les r glages n aient t d accueil s affiche ou que le message Mise jour copi s sur l appareil de PPC r ussie des r glages appuyez sur une touche s affiche sur l cran ACL Remarque Ce message n appara tra qu une seule fois Si vous ins rez nouveau la carte SD apr s avoir mis jour les r glages le message ne s affichera pas une nouvelle fois Le message suivant NE s affiche PAS sur l cran ACL apr s que vous avez essay de mettre les r glages jour l aide de la carte SD Mise jour r ussie des r glages appuyez sur une touche Les r glages n ont pas t mis jour Contactez votre clinicien fournisseur imm diatement Probl me cause possible LH5i projette de l eau sur votre visage Le r servoir d eau est trop plein De la condensation se forme dans le circuit respiratoire et dans le masque Le r servoir d eau fuit Le r servoir d eau est peut tre endommag ou fissur Le r servoir d eau nettoyable n est pas bien mont Solution V rifiez que le niveau de l eau se situe sous la marque du niveau maximum d eau R duisez les valeurs de r glage de l Hbi ou de l humidit relative partir du menu Contactez vo
67. s no se suministrar n las presiones de tratamiento Cuando se restablezca la energ a el dispositivo comenzar a funcionar nuevamente con la misma configuraci n 43 44 ZA PRECAUCIONES DEL S9 Tenga cuidado de no colocar el dispositivo en un lugar donde pueda ser golpeado o donde alguien pueda tropezar con el cable de alimentaci n Si coloca el dispositivo en el piso aseg rese de que no haya polvo en el rea y de que no haya ropa ropa de cama ni ning n otro objeto que pudiera bloquear la entrada de aire o cubrir la fuente de alimentaci n Aseg rese de que el rea alrededor del dispositivo est limpia y seca No cuelgue el tubo de aire a la luz solar directa ya que puede endurecerse con el tiempo y terminar agriet ndose No lave el filtro de aire El filtro de aire no es lavable ni reutilizable La tapa del filtro de aire protege el dispositivo en caso de que accidentalmente se derrame l quido sobre l Aseg rese de que el filtro de aire y la tapa del filtro est n colocados en todo momento Si las presiones son bajas el flujo de aire a trav s de los puertos de espiraci n de la mascarilla puede no ser suficiente para eliminar del tubo todo el gas espirado Es posible que se vuelva a respirar parte del aire espirado El flujo de aire para la respiraci n generado por estos equipos puede alcanzar una temperatura de hasta 6 C 11 F por encima de la temperatura ambiental Hay que tomar precauciones si la temperatura amb
68. s sobre la estaci n de acoplamiento del H5i o dentro de ella desenchufe el equipo del tomacorriente Desconecte la estaci n de acoplamiento del equipo CPAR y permita que se drene y se seque antes de volver a utilizarla A ADVERTENCIAS PARA EL TUBO DE AIRE e Si el tubo de aire sufre da os que provocan fugas de aire deje de utilizarlo No lave el tubo de aire en lavadoras de ropa o de platos ElClimateLine o ClimateLine MAX est dise ado para uso exclusivo con el H5i 45 46 Indica es de uso do S9 AutoSet O sistema auto ajust vel S9 AutoSet indicado para o tratamento da apneia obstrutiva do sono AOS em pacientes com peso superior a 30 kg 66 Ib O sistema auto ajust vel S9 AutoSet se destina a uso domiciliar e hospitalar Indica es de uso do S9 AutoSet for Her O sistema auto ajust vel S9 AutoSet for Her indicado para o tratamento da apneia obstrutiva do sono AOS em pacientes com peso superior a 30 kg 66 Ib O sistema auto ajustavel S9 AutoSet for Her se destina a uso domiciliar e hospitalar Indica es de uso do S9 Elite O sistema CPAP S9 Elite indicado no tratamento da apneia obstrutiva do sono AOS em pacientes com peso superior a 30 kg 66 Ib O sistema CPAP S9 Elite se destina a uso domiciliar e hospitalar Indica es de uso do S9 Escape Auto O sistema auto ajust vel do S9 Escape Auto indicado para o tratamento da apneia obstrutiva do sono AOS em pacientes com peso superior a 30 kg 66 I
69. s warranty gives you specific legal rights and you may also have other rights which vary from region to region For further information on your warranty rights contact your local ResMed dealer or ResMed office ZA GENERAL WARNINGS Read the entire manual before using these devices Inthe US Federal law restricts these devices to sale by or on the order of a physician Use these devices only for their intended use as described in this manual Use these devices only as directed by your physician or healthcare provider If you notice any unexplained changes in the performance of the device if it is making unusual or harsh sounds if the device or the power supply are dropped or mishandled if water is spilled into he enclosure or if the enclosure is broken discontinue use and contact your ResMed Service Center Do not open the S9 or H5i There are no user serviceable parts inside Repairs and servicing should only be performed by an authorized ResMed service agent Beware of electrocution Do not immerse the S9 device H5i docking station power supply or power cord in water Always unplug these devices before cleaning and make sure they are dry before plugging them back in Donot use bleach chlorine alcohol or aromatic based solutions moisturizing or antibacterial soaps or scented oils to clean the S9 H5i or air tubing These solutions may cause damage and reduce the life of these products Follow all preca
70. spositivos port tiles de diagn stico y cribado e Humidificadores Esta garantia solo tiene validez para el consumidor inicial No es transferible Si el producto falla en condiciones de utilizaci n normales ResMed reparar o reemplazar a opci n de ResMed el producto defectuoso o cualquiera de sus componentes Esta garant a limitada no cubre a ning n da o provocado por la utilizaci n indebida abuso modificaci n o alteraci n del producto b reparaciones efectuadas por cualquier organizaci n de servicio que no haya sido expresamente autorizada por ResMed para efectuar dichas reparaciones y c cualquier da o o contaminaci n debidos al humo de cigarrillos pipas cigarros o de cualquier otro tipo La garant a queda anulada si el producto se vende o revende fuera de la regi n en la que fue comprado originalmente Las reclamaciones de garant a en relaci n con productos defectuosos deben ser realizadas por el consumidor inicial en el punto de venta donde el producto fue comprado Esta garant a reemplaza cualquier otra garant a expresa o impl cita incluyendo cualquier garant a impl cita de comerciabilidad o aptitud para un fin determinado Algunas regiones o estados no permiten limitaciones respecto a la duraci n de una garant a impl cita por lo que es posible que la limitaci n estipulada anteriormente no se aplique en su caso particular ResMed no ser responsable de ning n da o incidental o emergente reclamado q
71. top d sactiv e Remarque SmartStart Stop n est pas disponible sur S9 Escape et S9 Escape Auto SmartStart Stop est activ e mais l appareil ne s arr te pas automatiquement lorsque vous retirez votre masque Le masque utilis est incompatible Utilisez uniquement l quipement recommand par ResMed Le patient utilise un masque nasal avec D sactivez SmartStart Stop une pression r gl e inf rieure a 7 cm H20 La pression augmente de fa on inappropri e Vous parlez vous toussez ou vous vitez de parler lorsque vous portez un masque nasal et respirez d une fa on inhabituelle respirez le plus normalement possible La bulle du masque vibre contre la Ajustez le harnais peau Affichage du message d erreur D fectuosit du circuit chauffant remplacez le circuit L appareil a t laiss dans un Laissez le refroidir avant de le r utiliser D branchez le environnement chaud c ble d alimentation et rebranchez le ensuite pour red marrer l appareil Votre circuit respiratoire chauffant Cessez l utilisation de votre circuit respiratoire ClimateLine ClimateLine ou ClimateLine est ou ClimateLine et communiquez avec votre clinicien ou d fectueux votre fournisseur En attendant utilisez un circuit respiratoire Standard ou SlimLine Affichage du message d erreur D fectuosit de humidificateur remplacez l humidificateur Lappareil a t laiss dans un Laissez le refroidir avant de le r utilise
72. tre fournisseur pour qu il vous le remplace V rifiez que le r servoir n est pas endommag et remontez le L air est trop chaud ou trop froid dans le masque La temp rature du circuit respiratoire du ClimateLine or ClimateLineMAX est trop lev e basse Caract ristiques g n rales Le module d alimentation 90 W Module d alimentation 30 W Temp rature de fonctionnement Humidit de fonctionnement Altitude de fonctionnement Temp rature de stockage et de transport Humidit de stockage et de transport Augmentez ou baissez la temp rature du circuit respiratoire chauffant a partir du menu Calibre de signal d entr e 100 240 V 50 60 Hz nominal des fins d utilisation en avion 110 V 400 Hz Consommation de courant typique 70 W 80 VA Consommation de courant maximale 110 W 120 VA Calibre de signal d entr e 100 240 V 50 60 Hz nominal a des fins d utilisation en avion 110 V 400 Hz Consommation de courant typique 20 W 30 VA Consommation de courant maximale 36 W 75 VA De 5 C a 35 C de 41 F a 95 F De 10 a 95 sans condensation Du niveau de la mer a 2 591 m 8 500 pi De 20 C a 60 C de 4 F a 140 F De 10 a 95 sans condensation 21 22 Compatibilit lectromagn tique Utilisation en avion Classification CEI 60601 1 Caract ristiques techniques des S9 Pression de fonctionnement Pression maximale d livr e en cas de d faillance dans des conditions uniform
73. tueux ou toute pi ce 25 26 Cette garantie limit e ne couvre pas a tout dommage r sultant d une utilisation incorrecte d un usage abusif d une modification ou d une transformation du produit b les r parations effectu es pour tout organisme qui offre des services n ayant pas t formellement autoris par ResMed a faire ces r parations c tout dommage ou contamination caus s par une cigarette une pipe un cigare ou autre article pour fumer La garantie est annul e pour les produits vendus ou revendus dans un pays autre que celui o ils ont t achet s I origine Les r clamations au titre de la garantie pour les produits d fectueux doivent tre pr sent es au lieu d achat par le client initial La pr sente garantie remplace toute autre garantie expresse ou implicite y compris toute garantie implicite de qualit marchande ou d ad quation un usage particulier Certains pays ou tats n autorisent pas les limitations de dur e pour les garanties implicites il est donc possible que la limitation susmentionn e ne s applique pas votre cas ResMed ne peut tre tenue pour responsable de tout dommage accessoire ou indirect r sultant de la vente de l installation ou de l utilisation de tout produit ResMed Certains pays ou tats n autorisent ni l exclusion ni la limitation des dommages accessoires ou indirects il est donc possible que la limitation susmentionn e ne s applique pas votre cas Cette garantie vo
74. ue haya ocurrido como resultado de la venta instalaci n o utilizaci n de cualquier producto ResMed Algunas regiones o estados no permiten la exclusi n o limitaci n de los da os incidentales o emergentes por lo que es posible que la limitaci n estipulada anteriormente no se aplique en su caso particular La presente garant a le otorga derechos legales espec ficos y es posible que usted tenga tambi n otros derechos que pueden variar de una regi n a otra Para obtener m s informaci n acerca de los derechos que le otorga la presente garant a comun quese con su distribuidor local de ResMed o con una oficina de ResMed ZA ADVERTENCIAS GENERALES Antes de usar estos equipos lea el presente manual en su totalidad En EE UU las leyes federales exigen que estos dispositivos sean vendidos nicamente por un m dico o por una orden m dica Utilice estos equipos solo para el uso indicado seg n las instrucciones de este manual Utilice estos equipos solo para el uso indicado por su m dico o proveedor de atenci n m dica Si observa alg n cambio inexplicable en el funcionamiento de este dispositivo si emite sonidos inusuales o speros si el dispositivo o la fuente de alimentaci n se caen o se maltratan si se derrama agua encima de la caja o si esta se rompe suspenda su uso y comun quese con su centro de servicio ResMed No abra el S9 o el H5i No hay piezas dentro que el usuario pueda reparar Las reparaciones y el mantenimiento
75. unit The power supply unit is being covered Make sure that the power supply unit is free from bedding by bedding clothes or other objects that could cover it Displays error message Tube blocked please check your tube Air tubing is blocked Check your air tubing and remove any blockages Displays error message High leak please check system setup and all connections There is excessive leak Adjust position of mask and headgear Air tubing is not connected properly Connect firmly at both ends The H6i flip lid is not latched correctly Close the flip lid ensuring that it clicks into place Displays error message Please close H5i flip lid attach tube and press any key H5i flip lid is not closed Close the flip lid ensuring that it clicks into place Air tubing is not connected properly Connect firmly at both ends Problem possible cause Solution The following message is displayed on the LCD after you try to update settings or copy data to the SD card Card error please remove SD card and contact service provider SD card is not inserted correctly You may have removed the SD card before settings were copied to the CPAP device Ensure that the SD card is inserted correctly Reinsert the SD card and wait for the home screen or the Settings updated successfully press any key message to appear on the LCD Note This message only appears once If you re insert the SD card after you have updated your settings the message will not
76. us octroie des droits reconnus par la loi Vous pouvez galement d tenir d autres droits qui varient en fonction du pays ou vous habitez Pour de plus amples informations sur vos droits de garantie veuillez contacter votre fournisseur local ou ResMed AVERTISSEMENTS D ORDRE GENERAL Lire le guide enti rement avant d utiliser ces appareils Selon la loi f d rale am ricaine cet appareil ne peut tre vendu aux Etats Unis que par un m decin ou sur prescription m dicale e Utiliser ces appareils uniquement selon l usage pr vu tel qu indiqu dans ce guide e Utilisez ces appareils conform ment aux instructions de votre m decin ou professionnel de la sant seulement Si vous remarquez tout changement inexpliqu dans la performance de l appareil sil fait des sons inhabituels ou durs ou que l alimentation baisse ou n est pas bien transmise si de l eau est renvers e dans l appareil ou l appareil est bris cessez l utilisation et contactez votre centre de services ResMed N ouvrez pas la S9 ou H5i Il ne contient aucune pi ce pouvant tre entretenue par l utilisateur Les r parations et l entretien doivent tre effectu s par un technicien agr ResMed uniquement e Risque d lectrocution Ne pas immerger la S9 la station d accueil de l H5i l alimentation lectrique ou le c ble d alimentation dans de l eau Toujours d brancher ces appareils avant de proc der au nettoyage et v rifier qu ils sont secs avant de
77. utions when using supplemental oxygen Explosion hazard do not use in the vicinity of flammable anesthetics Only use the ResMed 90W or 30W power supply units Make sure the power cord and plug are in good condition and the equipment is not damaged Keep the power cord away from hot surfaces Do not drop or insert any object into any tubing or opening Do not leave long lengths of air tubing around the top of your bed It could twist around your head or neck while you are sleeping s9 WARNINGS Advice contained in this manual should not supersede instructions given by the prescribing physician Do not use your S9 if there are obvious external defects or unexplained changes in performance Only ResMed air tubing and accessories should be used with these devices A different type of air tubing or accessory may alter the pressure you actually receive reducing the effectiveness of your treatment Blocking the air tubing and or air inlet of the S9 device while in operation could lead to overheating of the device If your clinician has told you to use the SD card to update the settings on your device and the Settings updated successfully message does not appear contact your clinician immediately A patient should not connect a device to the module connector port unless instructed to do so by their health care provider or physician Only ResMed products are designed to be connected to the module connector port Connecting other devices c
78. vamente en marcha el dispositivo Revise el tubo de aire y elimine la obstrucci n Desconecte el cable de alimentaci n y despu s vuelva a conectarlo para poner nuevamente en marcha el dispositivo Baje el nivel de configuraci n del humidificador y retire el agua del tubo de aire Aparece un mensaje de error Revise la unidad de alimentaci n de 30 90 W de ResMed e inserte el conector por completo El enchufe de CC no est completamente insertado en la parte trasera del dispositivo o se ha insertado muy lentamente Hay una fuente de alimentaci n que no es de ResMed conectada al dispositivo La fuente de alimentaci n est cubierta por ropa de cama Inserte el enchufe de CC completamente Quite la fuente de alimentaci n y reempl cela con una fuente de alimentaci n de ResMed Asegurese de que no haya ropa de cama ropa u otros objetos que pudieran cubrir la fuente de alimentaci n Problema Causa posible Soluci n Aparece un mensaje de error Tubo bloqueado revise su tubo El tubo de aire est obstruido Revise el tubo de aire y elimine la obstrucci n Aparece un mensaje de error Fuga grave verifique la configuraci n del sistema y todas las conexiones Hay una fuga excesiva La tapa del H5i no est trabada correctamente Ajuste la posici n de la mascarilla y el dispositivo para la cabeza El tubo de aire no est debidamente conectado Con ctelo firmemente en ambos extremos Cierre la tap
79. vat rio de gua 153 x 145 x 86 mm 6 0 x 5 7 x 3 4 pol Base de encaixe e reservat rio de gua vazio 0 67 kg 1 5 Ib Base de encaixe e reservat rio de gua vazio 0 77 kg 1 7 Ib 53 Capacidade de agua At a linha de enchimento maximo 380 ml Base de encaixe Termoplastico de engenharia de retardador de chamas aluminio Reservat rio de gua lav vel Pl stico moldado por inje o a o inoxid vel e veda o de silicone Reservat rio de gua Pl stico moldado por inje o alum nio e elast mero ermopl stico Especifica es t cnicas do tubo de ar Tubo de ar aquecido ClimateLine Pl stico flex vel e co m ponentes el tricos 2 m 6 p s e 6 pol di metro interno de 15 mm MAK Plastico flexivel e co m ponentes el tricos 1 9 m 6 p s e 3 pol di metro interno de 19 mm Tubo de ar aquecido ClimateLine Tubo de ar SlimLine Pl stico flex vel 1 8 m 6 p s di metro interno de 15 mm Tubo de ar Standard Pl stico flex vel 2 m 6 p s 6 pol di metro interno de 19 mm Temperatura de corte do tubo aquecido lt 106 F lt 41 C Observa es O fabricante reserva se o direito de alterar estas especifica es sem aviso pr vio As configura es de temperatura e umidade relativa exibidas para o ClimateLine ou ClimateLineM2X n o s o valores medidos Verifique com seu m dico ou prestador de servi os antes de usar o tubo de ar SlimLine com dispositivos que n o sejam o S9 ou o Hi
80. water tub Weight cleanable water tub Water capacity Docking station Cleanable water tub Water tub 24 dBA as measured according to ISO 17510 1 2002 26 dBA with uncertainty of 2 dBA as measured according to ISO 17510 1 2007 34 dBA with uncertainty of 2 dBA as measured according to ISO 17510 1 2007 6 0 x 5 5 x 3 4 153 mm x 140 mm x 86 mm 1 8 lb 835 9 Flame retardant engineering thermoplastic Recommended maximum supplemental oxygen flow 4 L min Non woven acrylic and polypropylene fibers with polypropylene carrier Polyester fiber The 22 mm conical air outlet complies with ISO 5356 1 150 F 65 C 165 F 74 C lt 106 F lt 41 C Docking station and water tub 6 0 x 5 7 x 3 4 153 mm x 145 mm x 86 mm Docking station and unfilled water tub 1 5 lb 0 67 kg Docking station and unfilled water tub 1 7 Ib 0 77 kg To maximum fill line 380 mL Flame retardant engineering thermoplastic aluminium njection molded plastic stainless steel and silicone seal njection molded plastic aluminium and thermoplastic elastomer Air tubing technical specifications ClimateLine heated air tubing Flexible plastic and electrical components 6 6 2 m 15 mm inner diameter ClimateLineM X heated air tubing Flexible plastic and electrical components 6 3 1 9 m 19 mm inner diameter SlimLine air tubing Flexible plastic 6 1 8 m 15 mm inner diameter Standard air tubing Flexible plastic 6 6 2 m 19
81. xpir via les orifices de ventilation du masque Cependant lorsque l appareil ne fonctionne pas le d bit d air propre d livr dans le masque est insuffisant et une r inhalation de l air expir peut se produire Si la r inhalation de l air expir dure plus de quelques minutes elle peut dans certains cas entra ner une suffocation Cela vaut pour la plupart des appareils de PPC En cas de coupure de courant ou de dysfonctionnement de l appareil retirer le masque Ces S9 peuvent tre r gl es pour d livrer des pressions allant jusqu 20 cm H 0 Dans le cas peu probable d une panne les pressions peuvent s lever jusqu 30 cm H20 Le d bit d oxyg ne doit tre ferm lorsque l appareil de pression positive n est pas en marche afin d emp cher l oxyg ne inutilis de s accumuler dans l appareil et de cr er un risque d incendie Loxyg ne est inflammable l oxyg ne ne doit pas tre utilis en fumant ou en pr sence d une flamme nue A PRECAUTIONS D USAGE CONCERNANT LA S9 Assurez vous de ne pas placer l appareil dans un endroit o il peut tre heurt ou l o quelqu un pourrait tr bucher sur le c ble d alimentation Si vous placez l appareil au sol v rifiez qu il n y a pas de poussi re ni de literie de v tements ou d autres objets susceptibles d obstruer l entr e d air ou de recouvrir le module d alimentation V rifier que la zone autour de l appareil est propre et s che Ne pas suspendre le circuit respiratoire