User Manual Digital Water Level Indicator for rain water storage tanks
Contents
1.
2. User Manual Digital Water Level Indicator for rain water storage tanks We congratulate you on the purchase of Digital Water Level measuring device You have pur chased a high quality product built to the highest standards of modern technology Before you start to assemble or operate the equipment please read the user manual with care and verify the parts supply for completeness List of parts supplied 1 The Digital Water Level Indicator 2 The stainless steel measurement probe red and white connection cables approx 10 feet long 3 The Measurement Sensor Box 4 Installation material a spare fuse and spacers Important notes on safety Please read and follow safety instructions carefully before assembly or using the device Equipment using a 120V AC supply may only be installed and commissioned by a qualified tradesman The assembly place must allow all possible safety precautions when laying the at tached cables Power supply cables and data cables may not be damaged or squeezed for any reasons Plan the assembly place so that you can reach the transformer easily and unplug it from the electrical outlet in dangerous situations Choose the assembly place so that children cannot play or be near the device or its connections without supervision Before opening the device disconnect it from the main supply unplug otherwise there is a serious danger of an electrical shock Fuses may only be replaced with standard compliant pa
3. e here 17 data cable terminal 18 screw cap 2 19 screw cap 1 20 active measuring length 21 When assembling be sure that the cable spacers are equally dis tributed over the cable length 22 Stainless steel probe 23 Tank floor 24 Screws must be blunted danger of injury 25 overflow 26 Tank side in dome 27 Sensor 28 Sensor control box Figure 4 Sensor assembly 3 Activation and calibration process Before energizing the equipment check and be sure that all electrical connections are correctly insulated and all covers are properly closed Now plug the plug in transformer into the mains socket particular to the equipment The green LED Power must light up The LCD display will run through range of number combinations shown These are used in the initialization of the equipment The initialization is completed as soon as the value stops and stays still i e the display shows no further fluctu ation The device now runs with the factory standard settings measuring cable length of 6 5 feet Should you have a different measuring cable length then the device must be calibrated To do this proceed as follows Calibration procedure 1 Fill the tank up to the maximum height If this is not possible then you should proceed with the alternative as follows Fill a bucket with water Put in the stainless steel probe with the red and white wires attached in the required measuring lengths completely subme
4. four screws Fuse T50mA Figure 2 Position of the fuse 2 2 Sensors and data cable connection The sensor electronics comprise of a stainless steel probe 22 with a red and a white connect ing cable 27 and the sensor control box 28 Figure 3 Sensor technology 1 Now the sensor control box 28 cover removed should be installed on the tank wall preferably in the man hole shaft of the Graf synthetic tank The location of the mounted sensor control box should be at least 6 inches above the overflow 25 The enclosed screws should be used to secure the device After fully tightening the screws the points that are showing themselves on the outside of the tank must be blunted to avoid injury 24 2 Measure the height from the bottom of the tank 23 to the end of the terminals 15 and 16 on the sensor control box 28 3 Shorten the connection cable to suit the measured height 4 After shortening the cable the distance between the cable fastening spacers 21 should be set equally along the entire length The cable fastening spacers prevent the red and white cables of the sensor from crossing over and thereby causing a slight distortion of the measurement readings If for any reason the cable fastening spacers cannot be mounted an additional distortion of the measurement reading of approximately 1 may result 5 Connect the sensor cable to the sensor as described in the following instructions Remove app
5. ibration process has not been carried out correctly This error code 602 occurs when the calibration button has been held too long In this case repeat the calibration process 701 Sensor error the sensor control box sends no signal Start with a check of all the connections of the at data cable in the display device and on the sensor STOP Before opening the equipment pull the plug out from the mains socket control box Control also for faulty cables check for current Check also the terminals of the sensor control box electrodes If all the cables have been correctly attached and there are no short circuits then the digital fill level indicator must function properly When the 701 code is still in the display then remove the sensor completely from the tank the sensor control box remains attached Attention make sure the cover of the digital display device is in place and secured with 4 screws Now reconnect the mains current The device must now show a value of 0 If this is not the case then the sensor is not functioning properly Should the green LED not light up then the device show no function Check once again all the connections and of course the fuse Don t forget to also check the mains fuse Should all at tempts be without success please get in touch with a professional Purchase date Device number Tank height Design and specifications are subject to change without notice Dated August 2011
6. illing level 4 LED On Figure 1 Overall equipment list Technical data Digital Water Level Indicator Sensor electronics Operating voltage 24V 60Hz Measuring current 12 volts Power consumption 3 watts Measuring frequency 200 Hz 20 kHz Output voltage 12 volts Data cable length 165 feet maximum Tank depth 10 feet Measurements LxWxD Measurements LxWxD 4 75 x3 1 x2 3 with protection IP54 3 6 x3 2 x2 with protection IP54 Fuse in the device T 50mA 2 Assembly 2 1 Digital Water Level Indicator housing installation Power must be disconnected during installation and service STOP Before opening the equipment pull the plug out from the mains socket For the connection to the 120V line please use a plug in transformer Should it necessary to open the housing take care that the device has been disconnected from the main power supply unplugged Mark out the hole positions on the wall and drill accordingly After having fixed the housing using the supplied screws and plugs attach the data cables and the 24V AC output of the plug in transformer to the terminal block The device fuses are found inside the cover Before changing the fuse it is important to dis connect the device from the main power supply pull out the plug Loosen the four screws holding the cover and lift carefully open Replace the faulty fuse with the same rated T50mA and recluse the cover Refasten the cover with the
7. roximately 1 4 of the insulation from both of the wires Next pass the red wire through the screw mounting 1 19 and tighten this lightly then connect the red wire to the terminal 16 The free white wire is now passed through the screw mounting 2 18 and tightened lightly then connect the white wire to the terminal 15 6 Now pass the end of the data cable 12 through the screw mounting 3 13 Lightly tighten the screw mounting and connect the cable wire cores of the data cable 12 to the double terminal 14 The connection of the data cable is reverse polarity protected Attention The screws should be tightened with care to ensure that they are not damaged through over tightening T Now recheck that all the screwed items and the sensor components have been fitted correctly Replace the cover of the sensor control box and secure this with the appropriate fastening screws Note The red and the white wires going down to the probe should be straight and smooth to be drawn taught by the weight of the stainless steel probe The stainless steel probe must hang just above the tank floor When setting the spacers please be sure to distribute them equally over the complete length as shown in Figure 4 The following illustration clarifies the context 22 23 12 Data cable 13 screw cap 3 14 Connection of the data cable is reverse protected 15 connect white wire here 16 connect red wir
8. rsed in the water then continue as from point 2 2 Press the calibration button The code 901 is shown in the LCD display 3 Release the calibration button and wait until the code 902 is shown in the LCD display 4 Now press the calibration button again quickly to save the determined value The code 903 is shown briefly in the LCD display 5 After this wait for a few moments until the display shows 100 Remark After the code 902 appears the calibration button must be immediately pressed if this is not done then the value will not be saved If this happens then wait a moment and repeat the process After the completion of the calibration the fill level indicator is shown in in this case 100 shows Slight variations may be caused by disturbance of the waters surface Note It is possible to re set the fill level indicator to the factory settings at any time To do this pull the plug in transformer from the mains and wait for a few seconds After this press the calibration button and hold it pressed and re plug the plug in transformer into the power outlet Hold the button pressed until the LCD code 601 is shown in the display 4 Error messages and fault elimination Directly following switching on and during the operation mode the digital fill level indicator checks the complete system equipment If an error is diagnosed it will be shown on the LCD display The following messages are possible 602 The cal
9. rts with the same nominal value All liability is excluded for damages which result from non compliance of these instructions or from improper handling of the device At chosen intervals in this hand book we will give directions for safety precautions These safety precautions have been specially marked Otto Graf GmbH Carl Zeiss Str 2 6 Tel 07641 5890 Kunststofferzeugnisse D 79 331 Teningen Fax 07641 58950 1 Description of the equipment The Digital Level Indicator has been developed especially for rain water usage Synthetic material tanks are used Cement and metal tanks are only conditionally usable With the calibration function the system is coordinated to the different tank heights The fill level in the tank is shown in 1 steps by a 3 digit LCD display The sensor electronics work with 12 volts of low current and is reverse polarity protected it is attached to the main device with a 65 foot data cable As soon as the calibration and the assembly are completed no further setting up is necessary The reference value for a 100 fill level remains stored in the case of a power failure Performance features Fill level indication in 1 steps Status LED which shows the operation in progress Self calibrating routine Permanent supervision of sensor electronics Error code message display The following picture shows your newly acquired device 1 Fastening holes 2 LCD Display 3 Button for setting the max f