Home
Brooks Instrument 1350E and 1355E User Manual
Contents
1. molten metal Failure to heed warning can result in serious personal injury and or damage to the equipment Capacities 1350 Series Refer to Tables 1 1 or 1 2 or 1 3 and 1 4 1355 Series Refer to Tables 1 3 and 1 4 or 1 5 Accuracy 1350 Series Standard Accuracy of 10 of full scale from 100 to 10 of scale reading 1355 Series Standard 5 of full scale from 100 to 10 of scale reading Repeatability 0 5 full scale Rangeability 10to 1 Pressure 200 psig at temperatures up to 250 F Pressure Drop Inquire at factory Flow Meter Assembly Pressure Equipment Directive 97 23 EC Note Equipment falls under Sound Engineering Practice SEP according to the directive Section 1 Introduction Models 1350E and 1355E Installation and Operation Manual X VA 1350E eng Part Number 541BO082AAG April 2009 Scales 1350 Series Length 65 mm nominal Graduations Standard 0 65mm or 0 100 linear reference scale with air or water calibration table 1355 Series Length 150mm nominal Graduations Standard 0 150 mm or 0 100 linear reference scale with air or water calibration table Optional for either 65 mm or 150 mm direct reading scale ceramic ink fused on glass tube or metal scale plate mounted beside tube Type Standard Ceramic ink fused on meter tube with contrasting yellow background Materials of Construction Metering Tubes Borosilicate glass Floats Glass 316 stainless steel sapphire Carbo
2. 4 Section 1 Introduction Models 1350E and 1355E Table 1 3 Tube and Float Code Detachable Scale Option 1st Digit MODEL 1355 TUBE 1 65 R 2 15 A 2 65A R 2 15 AA 2 65B amp D R 2 15 AAA 2 65C R 2 15 B 3 65 R 2 15 C 4 65 R 2 15 D 5 65 R 6 15 A 6 65 R 6 15 B Installation and Operation Manual X VA 1350E eng Part Number 541BO082AAG April 2009 Table 1 4 Tube and Float Code Detachable Scale Option 2nd amp 3rd Digits METER ACCURACY STANDARD 1350 10 1355 5 R 2 65 A R 2 65 B R 2 65 C R 2 65 D R 6 65 A R 6 65 B NO TUBE lt vuZzSerxcronmoog gt Table 1 5 Capacities for Sho Rate Model 1355E Rib Guided Tubes Spherical Floats FLOAT MATERIAL GLASS STN STL SAPPHIRE CARBOLOY TANTALUM ALUMINUM DETACHABLE SCALE INSCRIPTION CALIBRATED 1350 5 1355 2 GLASS STN STL SAPPHIRE CARBOLOY TANTALUM ALUMINUM NONE ALUMINUM SPOOL FLOAT FOR 15 CC MIN AIR AVAILABLE ONLY WITH R 2 15 AAA METER TUBE NO FLOAT MATERIAL R 2 15 AAA SAPPHIRE R 2 15 AA STN STL CARBOLOY SAPPHIRE 2 R 2 15 D STN STL CARBOLOY SAPPHIRE R 2 15 A STN STL CARBOLOY SAPPHIRE STN STL CARBOLOY TANTALUM MAXIMUM FLOW RATE WATER CC MIN AIR CAPACITIES RIB GUIDE TUBES SPHERICAL FLOATS FOR USE WITH 1355 SERIES ONLY MODEL CODE SCALE ON TUBE 0 150 MM 10 100 0 100 LINEAR 471SCCM 73 3 SCC M 140 SCC M 238 SCC M 260 SCC M 83 8 SCC M
3. once the PED has been complied with Section 1 of this manual contains important safety and operating instructions related to the PED directive Meters described in this manual are in compliance with EN directive 97 23 EC module H Conformity Assessment All Brooks Instrument Flowmeters fall under fluid group 1 Meters larger than 25mm or 1 inch are in compliance with category Il Ill of PED Meters of 25mm or 1 inch or smaller are Sound Engineering Practice SEP Installation and Operation Manual X VA 1350E eng Part Number 541B082AAG April 2009 Models 1350E and 1355E Dear Customer We appreciate this opportunity to service your flow measurement and control requirements with a Brooks Instrument device Every day flow customers all over the world turn to Brooks Instrument for solutions to their gas and liquid low flow applications Brooks provides an array of flow measurement and control products for various industries from biopharmaceuticals oil and gas fuel cell research and chemicals to medical devices analytical instrumentation semiconductor manufacturing and more The Brooks product you have just received is of the highest quality available offering superior performance reliability and value to the user It is designed with the ever changing process conditions accuracy requirements and hostile process environments in mind to provide you with a lifetime of dependable service We recommend that you read this manu
4. 09 Figure 5 1 Parts Drawing Sho Rate Models 1350E and 1355E Installation and Operation Manual X VA 1350E eng Part Number 541BO082AAG April 2009 Table 5 1 Parts List Sho Rate Models 1350E and 1355E ft i ae 7 menna Tube assem 217 Glass Metering Tube Ball Float Size 1 5 1350 Only Size 1 3 32 Glass Size 1 3 32 316 SS Size 2 1 8 Glass Size 2 1 8 Sapphire Size 2 1 8 316 SS Size 2 1 8 Carboloy Size 2 1 8 Tantalum Size 5 7 32 Glass Size 5 7 32 316 SS Size 6 1 4 Glass Size 6 1 4 Sapphire Size 6 1 4 316 SS Size 6 1 4 Carboloy Size 6 1 4 Tantalum Seal End Fitting Outlet Aluminum Brass 316 SS Seal Spindle Aluminum Brass 316 SS Valve End Fitting inlet Aluminum Brass 316 SS Valve Plug Aluminum Brass 316 SS Upper Seal Spindie O ring Buna Viton Teflon Lower Seal Spindle O ring Buna Viton Teflon Adapter O ring Buna Viton Teflon Plug O ring Buna Viton Teflon Side Plate STD 1350 Aluminum STN STL 1355 Aluminum STN STL Side Plate 1350 Standard Aluminum STN STL For Detached Scaie Aluminum STN STL Recommended Spare Parts Section 5 Parts List Models 1350E and 1355E Description Ref lQty No Cont d 1355 Standard Aluminum Stn Sti
5. 128 SCC M 245 SCCM 416 SCC M 454 SCC M 361 SCC M 491 SCC M 790 SCC M 1170 SCC M 1250 SCCM 0 790 SLPM 1 04 SLPM 1 60 SLPM 2 32 SLPM 2 46 SLPM 2 25 SLPM 2 92 SLPM 4 42 SLPM 6 35 SLPM 6 74 SLPM GLASS SAPPHIRE STN STL CARBOLOY SAPPHIRE STN STL CARBOLOY 6 SAPPHIRE R 6 15 B STN STL CARBOLOY TANTALUM R 2 15 C NOTE ALL AIR FLOWS ARE AT 14 7 PSIA AND 70 DEGREES F 3 69 SLPM 4 81 SLPM 7 23 SLPM 10 1 SLPM 10 6 SLPM 8 26 SLPM 10 6 SLPM 15 7 SLPM 22 0 SLPM 23 3 SLPM 22 6 SLPM 28 6 SLPM 41 6 SLPM 58 1 SLPM 61 4 SLPM FLOW RATES SHOWN ARE MAXIMUM CAPACITIES DIRECT READ SCALES MAY END AT SLIGHTLY DIFFERENT MAXIMUM FLOWS Installation and Operation Manual Section 1 Introduction X VA 1350E eng Part Number 541BO082AAG April 2009 Models 1350E and 1355E 1 3 Optional Equipment a a Standard Needle Valve The standard needle valve can be supplied integrally mounted to the inlet or outlet of the instrument For more details on the needle valve go to our website BrooksInstrument com select Documentation Precision Valves amp Flow Controllers select Brooks Line IV CART 8503 or 8504 valves Flow Contollers Flow controllers can be supplied integrally mounted to the inlet or outlet of the instrument For the flow controller s complete instruction manual go to our website BrooksInstrument com select Documentation Precision Valves amp Flow Controllers select FC8800 or FC
6. 8900 Section 1 Introduction Models 1350E and 1355E THIS PAGE WAS INTENTIONALLY LEFT BLANK Installation and Operation Manual X VA 1350E eng Part Number 541BO082AAG April 2009 Installation and Operation Manual X VA 1350E eng Part Number 541B082AAG April 2009 2 1 Receipt of Equipment 2 2 Unpacking Section 2 Installation Models 1350E and 1355E When the equipment is received the outside of the packing case should be checked for any damage incurred during shipment If the packing case is damaged the local carrier should be notified at once regarding his liability Remove the envelope containing the shipping list Carefully remove the equipment from the packing case and inspect for any damaged or missing parts In the event that the meter is damaged during shipment the Product Service Department Brooks Instrument LLC Hatfield PA 19440 should be contacted to obtain a return shipment form Brooks Instrument 407 W Vine Street P O Box 903 Hatfield PA 19440 USA Toll Free 888 554 FLOW 3569 Tel 215 362 3700 Fax 215 362 3745 E mail BrooksAm BrooksInstrument com www BrooksInstrument com Brooks Instrument Brooks Instrument Neonstraat 3 1 4 4 Kitasuna Koto Ku 6718 WX Ede Netherlands Tokyo 136 0073 Japan P O Box 428 Tel 81 0 3 5633 7100 6710 BK Ede Netherlands Fax 81 0 3 5633 7101 Tel 31 0 318 549 300 Email BrooksAs BrooksInstrument com Fax 31 0 318 549 309 E ma
7. E E Brooks Instrument LLC TEON nre E S E I DuPont de Nemours amp Co MION Aane ea R DuPont Performance Elastomer Brooks Instrument 407 West Vine Street P O Box 903 Hatfield PA 19440 0903 USA T 215 362 3700 F 215 362 3745 E Mail BrooksAm BrooksInstrument com www BrooksInstrument com Brooks Instrument Neonstraat 3 6718 WX Ede Netherlands T 31 0 318 549 300 F 31 0 318 549 309 E Mail BrooksEu BrooksInstrument com Copyright 2009 Brooks Instrument LLC All rights reserved Printed in U S A Brooks Instrument 1 4 4 Kitasuna Koto Ku Tokyo 136 0073 Japan T 81 0 3 5633 7100 F 81 0 3 5633 7101 E Mail BrooksAs BrooksInstrument com BROOKS INSTRUMENT
8. For Detached Scale Aluminum Stn Stl Front Shield 1350 1355 Back Plate Aluminum Det D R Scale Stn Sti Scale Screws Stn Stl Scale Washers Stn Stl Scale Nuts Aluminum Bezet 1350 No Valve 1350 With Vaive 1355 No Valve 1355 With Valve Optional Vaive Assembly Cartridge Valve Brass Buna N Low Brass Buna N Med Brass Buna N Hi 316 S S Viton Low 316 S S Viton Med 316 S S Viton Hi NRS Valve Brass Buna N Size 1 Brass Buna N Size 2 Brass Buna N Size 3 Brass Buna N Size 4 Brass Buna N Size 5 Brass Buna N Size 6 316 S S Viton Size 1 316 S S Viton Size 2 316 S S Viton Size 3 316 S S Viton Size 4 316 S S Viton Size 5 316 S S Viton Size 6 1 8 NPT Thd Adapter w Locknut Aluminum w Buna Brass w Buna 316 SS w Viton 1 8 NPT Adapter Aluminum w Buna Brass w Buna 316 SS w Viton 1 4 NPT Adapter Aluminum w Buna Brass w Buna 316 SS w Viton 1 8 Compression Adapter Brass w Buna 316 SS w Viton 1 4 Compression Adapter Brass w Buna 316 SS w Viton 1 4 1 0 Hose Adapter Aluminum w Buna Brass w Buna 316 SS w Viton Orifice O ring NRS Buna N Viton Cartridge Valve Buna N Viton 5 3 Installation and Operation Manual X VA 1350E eng Part Number 541BO082AAG Models 1350E and 1355E April 2009 LIMITED WARRANTY Seller warrants that the Goods manufactured by Seller will be free from de
9. Installation and Operation Manual X VA 1350E eng Part Number 541BO082AAG April 2009 Sho Rate 50 Model 1350E and Sho Rate 150 Model 1355E Sizes 2 6 7 Model 1350E Model 1350E Model 1350E Sho Rate 50 JE Sho Rate 50 Sho Rate 50 With optional Integral s With optional no valve O G flow controller needle valve Model 1355E E Model 1355E Model 1355E Sho Rate 150 A ee Sho Rate 150 Nyt Sho Rate 150 no valve gt is With optional Integral With optional Loe flow controller a needle valve BROOKS www BrooksInstrument com IN ST RUMENT Installation and Operation Manual X VA 1350E eng Part Number 541BO082AAG Models 1350E and 1355E April 2009 Essential Instructions Read this page before proceeding Brooks Instrument designs manufactures and tests its products to meet many national and international standards Because these instruments are sophisticated technical products you must properly install use and maintain them to ensure they continue to operate within their normal specifications The following instructions must be adhered to and integrated into your safety program when installing using and maintaining Brooks Products Read all instructions prior to installing operating and servicing the product If this instruction manual is not the correct manual please see back cover for local sales office contact information Save this instruction manual for future reference If you do not unde
10. SSION 174 1 D HOSE 174 VCR_ M INCH DIMENSIONS ARE MM 1 2 HOLES OUTLET CONN sy o 1350 1355 SHO RATE PLAST IC gt SHIELDING SHOWN OPTIONAL Figure 2 3 Dimensions Sho Rate 1350E amp 1355E with Integral Flow Controller Section 2 Installation Installation and Operation Manual X VA 1350E eng Part Number 541B082AAG 4 sa r FRONT OF PANEL MOUNTING 54 0 J B Dia 2 Places NRS Open Threaded Adapters amp Lock Nuts Conn Adapter 1 8 NPT 1 4 NPT 59 15 1 88 22 2 7 8 Dia 59 VALVE OUTLET 1 50 imu 15 0 VALVE er 1 50 P3aq7 384 ra i i l NO VALVE 7A VALVE OUTLET 150 78 dia 59 ep 38 1 15 0 VALVE INL 212 Mee 540 1i A i p fi 1 00 NRS Open Ba ha For Panel Thickness For Panel Thickness Connection 1 8 or Less Greaer than 1 8 1 00 Remove rear sheild If 4 furnished wl Cartridge pen Model 1355E VB Valve Inlet with Alu nen mounting on panels thicker than 1 4 L AN 10050 2 O Ring Boss Seal All Fittings 1 4 NPT 812 ee one 1 8 NPT 1 8 Compression 625 i 719 159
11. Y TANTALUM GLASS SAPPHIRE SIN STL CARBOLOY TANTALUM RIBBED TUBES SPHERICAL FLOATS MAXIMUM FLOW RATE WATER AIR CODE mre CODE JBS JC1 JC6 JB3 JD3 KB9 KC3 KC amp KB6 KDI LB8 LCG LB5 LD4 R 6 65 A R 6 65 B GLASS SAPPHIRE STN STL CARBOLOY TANTALUM GLASS SAPPHIRE STN STL CARBOLOY TANTALUM 8 0 30 0 12 0 PC5 44 0 19 0 PDI 70 0 28 0 PB3 100 PB2 30 0 PD7 110 PDE 140 FLOW RATES GIVEN ARE MAXIMUM VALUES AIR FLOWS ARE AT 14 7 PSIA AND 70 DEGREES F Table 1 2 Capacities for Sho Rate Model 1350E Plain Tapered Tubes Spherical Floats SCFH TUBE AND FLOAT AIR 1 65A GLASS a2 265A GLASS a 2 65B85TN 5TL_ 50 3 65A GLASS 60 12 4 EB4 S65BSTNSTL 10 101 EBB PLAIN TAPER TUBES SPHERICAL FLOATS Press Drop Inches W C CODE 1 0 AB4 22 BA7 10 8 CA4 10 4 FC3 4 65A GLASS seess e 65A GLASS 658STNSTL___ so GPH ee AND FLOAT WATER ae ee ae ee ce en es posne o f es cas La cc a a Press Drop Inches W C 25 FC8 60 GB6 214 GC1 73 HB8 6 65A GLASS 6 65B STN STL G 65ECARBOLOY 120 FLOW RATES ARE MAXIMUM VALUES AIR FLOWS ARE AT 14 7 PSIA AND 70 DEGREES F PRESSURE DROPS ARE APPROXIMATE GLASS r 7 4 65D STN STL a 5 65C GLASS ee eros S 65DSTNSTL 17 _ 385 GC5 292 HC5 400 HD3 6 65C GLASS HC7 6 65D STN STL HD1 6 65F CARBOLOY 3 sw P 1
12. al expansion of the liquid which can cause rupture of the meter and possible personal injury ACAUTION Care must be taken in the system piping to this instrument to prevent sudden excessive pressure or flow surges Protective devices should be installed upstream from this instrument such as flow controllers pressure regulators pressure snubbers and rupture discs HORIZONTAL VERTICAL LINE LINE D FLOWMETER FLOWMETER B A inlet Valve B Outlet Valve C Bypass Valve D Control Valve E Drain Valve Figure 2 1 Typical Flowmeter Installation It is recommended that a final leak test of the system plumbing and meter be performed before subjecting it to process fluid See Section 4 Paragraph 4 2 e 2 3 2 4 Section 2 Installation Installation and Operation Manual X VA 1350E eng Part Number 541BO082AAG Models 1350E and 1355E April 2009 Model 1350E V Valve Inlet FRONT OF PANEL MOUNTING 65 mm Scale nominal B Dia 2 Places Thread Adapters amp Lock Nuts Conn Adapter 1 8 NPT 1 4 NPT IER 50722 2 7 8 Dia 59 Au VALVE OUTLET wma 150 i VALVE INLET B 381 VALVE OUTLET TAR i 59 7 8 nia 750 j VALVE INLET T T For Panel Thickness For Panel Thickness 1 8 or Less Greater than 1 8 Remove rear shield if A Model 1350E VB Valve Inlet wit
13. al in its entirety Should you require any additional information concerning Brooks products and services please contact your local Brooks Sales and Service Office listed on the back cover of this manual or visit www BrooksInstrument com Yours sincerely Brooks Instrument Models 1350E and 1355E Installation and Operation Manual X VA 1350E eng Part Number 541BO082AAG April 2009 THIS PAGE WAS INTENTIONALLY LEFT BLANK Installation and Operation Manual X VA 1350E eng Part Number 541BO082AAG April 2009 Contents Models 1350E and 1355E Section 1 Introduction Capacities for Sho Rate Model 1355E Rib Guided Tubes Spherical Floats c ceceseeeeeeseeeeetteeeeeees 1 4 Paragraph Page Number Number TEA DOSCNIPUOM secesieivicctateceist Mouceedeceetiwcddceres Ot iwadedecess tanvetevdhstuwadedeees st EEE ENE weeees aasateeehatinedadeeelst omen 1 1 d2 Specificato NS cisean a sees nesta nett a aN a G E Heda G abatencudtnns AE RAER 1 1 1 3 Optional EQUIPMEN sssri taninai ne teeter aa aE eaaa aaaea aaiae aa E aa ENO 1 5 Section 2 Installation Paragraph Page Number Number 221 Receipt OF EQUIPIMONI sriain iaaa a Ea eaat Saia NE scald yatlaek et antecedent saysetebetienesiehetanadacees 2 1 ee Unpack oee E E sures slat aaaedaanilaaeeanaiiuecaas 2 1 223 Return SMPME Niess nnie cevssatenie a aaa eaea N aaae N eaaa a a aa a aaa EE EEA 2 2 2 4 Recommended Storage Practice cccccccecesneeeseneeeeeeeeeeeee
14. e Scale Option 2nd amp 3rd Digits 0 ccceceeeseeeeeeeeeeeeeeeeeeeeeeeeeesenaeeseas 1 4 1 5 5 1 Parts List Sho Rate Models 1350E and 1355E Contents Models 1350E and 1355E THIS PAGE WAS INTENTIONALLY LEFT BLANK Installation and Operation Manual X VA 1350E eng Part Number 541BO82AAG April 2009 Installation and Operation Manual X VA 1350E eng Part Number 541BO082AAG April 2009 1 1 Description 1 2 Specifications Section 1 Introduction Models 1350E and 1355E The Sho Rate Flowmeters are variable area glass tube flow rate indicating meters The basic elements are a tapered glass metering tube and a metering float Features include quick and simple removal or installation of the tube and float while the meter remains in the process piping AWARNING Do not operate this instrument in excess of the specifications listed below Failure to heed this warning can result in serious personal injury and or damage to the equipment AWARNING Glass metering tubes are designed for operation up to the maximum operating pressures and temperatures as specified herein Due to the inherent brittle characteristics of glass and conditions beyond our control tube breakage could result even within specified operating conditions Do not use glass tube meters with fluids that are toxic or chemically react with glass such as water above 140 F steam alkalis fluorine hydrofluoric acid or
15. eneeeeeaaaeecaaaeeseeaaeeeseaaaeeseeaaessecaeeeeseaaeeseeeseeaeees 2 2 265 Installation wiecsssivasesGintes seusieteiian an a ae Aa A AEEA Ea Eaa AA ae aaa EAEE EEAS Aa Aaaa deede 2 3 Section 3 Operation Paragraph Page Number Number 3 1 Operation e A ea a a Ra A E aE EEN E EE ARATE 3 1 Section 4 Maintenance Paragraph Page Number Number A 1 Disassembly amp Clean gisis iinan anaana N aaea a aE E aaa EEE aaa aah Siaa 4 1 d2 ReasSembly Procedure canara E E 4 1 Section 5 Parts List Paragraph Page Number Number ST Genra eae a E a S 5 1 Figures Figure Page Number Number 21 Typical Flowmeter Instalaioih e sasssa O 2 3 2 2 Dimensions Sho Rate 350E sssini a NAA ENEN SA N A NN 2 4 2 3 Dimensions Sho Rate 1350E and 1355E with Integral Controller c ccccccceeeeeeeeeeeeeeeeeeeeeeeeseeaeeeseneees 2 5 24 Dimensions Sho Rate 1355 csts osen aaa E aANT AAEN AAAA S aN KEDAN dene 2 6 5 1 Parts Drawing Sho Rate Models 1350E and 1355E 0 ecceeeeseeeeeeeeeeeeeceeeceeneeeeseeeeeeesaaeeesecaeeeseeeeeeeseeeeee 5 2 Tables Table Page Number Number 1 1 Capacities for Sho Rate Model 1350E Rib Guided Tubes Spherical Floats cc ceeeeceeeeeseeeeeetteeeeeees 1 3 1 2 Capacities for Sho Rate Model 1350E Plain Tapered Tube Spherical Floats 0 cceececeeeeeeseeeeeeeees 1 3 1 3 Tube and Float Code Detachable Scale Option 1st Digit ccecceeeeeeeeeeeeeeceeeaeeeeeeeeeeseeeeeessaaeeeenes 1 4 1 4 Tube and Float Code Detachabl
16. erm storage is required for equipment as supplied by Brooks Instrument it is recommended that said equipment be stored in accordance with the following a Within the original shipping container b Stored in a sheltered area preferably a warm dry heated warehouse c Ambient temperature 70 F 21 0 C nominal 110 F maximum 45 F minimum 43 C maximum 7 1 C minimum d Relative humidity 45 nominal 60 maximum 25 minimum Upon removal from storage a visual inspection should be conducted to verify the condition of equipment is as received If the equipment has been in storage for an excess of two 2 years or in conditions in excess of those recommended all pressure boundary seals should be replaced and the device subject to a hydrostatic pneumatic pressure test to 150 of rated pressure Installation and Operation Manual X VA 1350E eng Part Number 541BO082AAG April 2009 Section 2 Installation Models 1350E and 1355E 2 5 Installation See Figures 2 1 2 2 2 3 2 4 and 2 5 The flowmeter should be mounted within 6 of true vertical The inlet connection to the flowmeter is in the bottom end fitting The connections are normally horizontal female NPT Be sure the piping is adequately supported to prevent undue strain on the meter AWARNING If the inlet and outlet valves adjacent to the flowmeter are to be closed for any reason the flowmeter must be completely drained Failure to do so may result in therm
17. fects in materials or workmanship under normal use and service and that the Software will execute the programming instructions provided by Seller until the expiration of the earlier of twelve 12 months from the date of initial installation or eighteen 18 months from the date of shipment by Seller Products purchased by Seller from a third party for resale to Buyer Resale Products shall carry only the warranty extended by the original manufacturer All replacements or repairs necessitated by inadequate preventive maintenance or by normal wear and usage or by fault of Buyer or by unsuitable power sources or by attack or deterioration under unsuitable environmental conditions or by abuse accident alteration misuse improper installation modification repair storage or handling or any other cause not the fault of Seller are not covered by this limited warranty and shall be at Buyer s expense Goods repaired and parts replaced during the warranty period shall be in warranty for the remainder of the original warranty period or ninety 90 days whichever is longer This limited warranty is the only warranty made by Seller and can be amended only in a writing signed by an authorized representative of Seller BROOKS SERVICE AND SUPPORT Brooks is committed to assuring all of our customers receive the ideal flow solution for their application along with outstanding service and support to back it up We operate first class repair facilities l
18. h Aluminum Bezel INRS Nnen Cartridge Open furnished when mounting on panels thicker than 1 4 AN 1050 2 1 4 ID Hose 0 Ring Boss Seal All Fittings 1 4 NPT 1 4 Compression B12 43 Loe 206 L h 21 4 1 8 NPT 1 8 Compression 625 wo 19 l h 8 Lo Dimension A Connection Adapter Inches Millimeter Figure 2 2 Dimensions Sho Rate 1350E Installation and Operation Manual Section 2 Installation X VA 1350E eng Part Number 541BO082AAG April 2009 Models 1350E and 1355E Cc Cc JD Model 1350E 8800 CLSDICLSD INCH MM_ NCH Controller on 3 7 4 vale 52 17 55 2 6 38 2 17 55 2 10 78 Inlet O NLT INCETJOUTLETIOUTLET po CONN CONN CONN CONN CONN sie F bane aaa H NPT NPT REGULATING VALVE i gi Bie DIMENSIONS 31 8 BE OUTLET CONN H 1 005Q 1350 1355 SHO RATE 25 4 PLASTIC SHIELDING DET SCALE SHOWN 4 OPTIONAL 8800 FLOW CONTROLLER 1 42 MIN 36 0 MTG BRACKET 1 77 MAX CROTATABLE ADJUSTABLE 45 0 INLET INLETJOUTLETJOUTLET SONN eoRN pee a CONN SIZE MTG BRACKET 178 NPT ROTATABLE ADJUSTABLE 174 NPT 1 8 COMPRESSION 8900 FLOW CONTOLLER 174 COMPRE
19. il BrooksEu BrooksInstrument com Carefully unpack the meter and inspect it for any damage that may have occurred during shipment The flowmeters are shipped completely assembled and tested It should not be necessary to tighten or adjust any of the parts when it is received 2 1 2 2 Section 2 Installation Installation and Operation Manual X VA 1350E eng Part Number 541B082AAG Models 1350E and 1355E April 2009 2 3 Return Shipment ESSS_SSSS eee ee ee ee Do not return any assembly or part without a Return Materials Report The Return Materials Report is available from all District Sales Offices and the Product Service Department Hatfield PA 19440 Information describing the problem corrective action if any and the work to be accomplished at the factory must be included Brooks Instrument 407 W Vine Street P O Box 903 Hatfield PA 19440 USA Toll Free 888 554 FLOW 3569 Tel 215 362 3700 Fax 215 362 3745 E mail BrooksAm BrooksInstrument com www BrooksInstrument com Brooks Instrument Brooks Instrument Neonstraat 3 1 4 4 Kitasuna Koto Ku 6718 WX Ede Netherlands Tokyo 136 0073 Japan P O Box 428 Tel 81 0 3 5633 7100 6710 BK Ede Netherlands Fax 81 0 3 5633 7101 Tel 31 0 318 549 300 Email BrooksAs Brooks Instrument com Fax 31 0 318 549 309 E mail BrooksEu BrooksInstrument com 2 4 Recommended Storage Practice S Se eee ee ee a ae If intermediate or long t
20. l e 183 Dimension A Connection Adapter Inches Millimeters 9 6 Figure 2 4 Dimensions Sho Rate 1355E Installation and Operation Manual Section 3 Operation X VA 1350E eng Part Number 541B082AAG April 2009 Models 1350E and 1355E 3 1 Operation After the flowmeter has been installed in the flow system it is ready for operation An optional built in needle control valve may be provided to control the flow through the flowmeter These control valves are designed for fine control Excessive tightening may damage the valve seat and limit its effectiveness as a control valve If tight shut off is required it is recommended that a separate shut off valve should be installed in the line immediately before the flowmeter Flow indication is measured using the center of the spherical float as the reference point 3 1 3 2 Section 3 Operation Models 1350E and 1355E THIS PAGE WAS INTENTIONALLY LEFT BLANK Installation and Operation Manual X VA 1350E eng Part Number 541BO082AAG April 2009 Installation and Operation Manual X VA 1350E eng Part Number 541B082AAG April 2009 4 1 Disassembly and Cleaning Section 4 Maintenance Models 1350E and 1355E A WARNING METER CONTROLLER SEAL COMPATIBILITY Products in this manual may contain metal or elastomeric seals gaskets O rings or valve seats It is the user s responsibility to select materials that are compatible with their process and p
21. loy tantalum Structural Members End fittings Chrome plated brass black anodized aluminum 316 stainless steel Side Plates Standard Black anodized aluminum Optional 316 stainless steel Window Clear polycarbonate Back Window Milk white polycarbonate Float Stops Standard Teflon Optional 316 Stainless Steel Tube Packing Standard Buna N Brass and aluminum meters Viton A fluoroelastomers 316 stainless steel meters Optional Teflon EPM also known as EPR O rings Standard Buna N Brass and aluminum meters Viton A fluoroelastomers 316 stainless steel meters Optional Teflon not available with needle valves EPM Kalrez Connections Standard Horizontal female 1 8 NPT threaded adapters with locknuts for front of panel mounting Multi tube meters Individual 1 8 NPT horizontal inlet and outlet Manifold connection 1 8 NPT on inlet with individual outlet or manifold outlet with individual inlet connections Dimensions Refer to Figures 2 2 and 2 3 Installation and Operation Manual X VA 1350E eng Part Number 541B082AAG April 2009 Section 1 Introduction Models 1350E and 1355E Table 1 1 Capacities for Sho Rate Model 1350E Rib Guided Tubes Spherical Floats METER TUBE SIZE NO R 2 65 A R 2 65 B R 2 65 C R 2 65 D FLOAT MATERIAL GLASS SAPPHIRE STN STL CARBOLOY TANTALUM GLASS SAPPHIRE STN STL CARBOLOY TANTALUM GLASS SAPPHIRE SIN STL CARBOLO
22. ocated around the world to provide rapid response and support Each location utilizes primary standard calibration equipment to ensure accuracy and reliability for repairs and recalibration and is certified by our local Weights and Measures Authorities and traceable to the relevant International Standards Visit www Brooks nstrument com to locate the service location nearest to you START UP SERVICE AND IN SITU CALIBRATION Brooks Instrument can provide start up service prior to operation when required For some process applications where ISO 9001 Quality Certification is important it is mandatory to verify and or re calibrate the products periodically In many cases this service can be provided under in situ conditions and the results will be traceable to the relevant international quality standards CUSTOMER SEMINARS AND TRAINING Brooks Instrument can provide customer seminars and dedicated training to engineers end users and maintenance persons Please contact your nearest sales representative for more details HELP DESK In case you need technical assistance Americas 1 888 554 FLOW Europe T 31 0 318 549 290 Asia T 81 0 3 5633 7100 Due to Brooks Instrument s commitment to continuous improvement of our products all specifications are subject to change without notice TRADEMARKS BROOKS os ae errer E E E EE Brooks Instrument LLC Kalrez DuPont Performance Elastomer NRS a S E EE Brooks Instrument LLC Sho Rate
23. rocess conditions Using materials that are not compatible with the process or process conditions could result in the Meter or Controller leaking process fluid outside the pressure boundary of the device resulting in personnel injury or death It is recommended that the user check the Meter or Controller ona regular schedule to ensure that it is leak free as both metal and elastomeric seals gaskets O rings and valve seats may change with age exposure to process fluid temperature and or pressure It is recommended the user periodically inspect the tube and float and clean if necessary Dirt or foreign materials adhering to the tube and float may Cause inaccuracy and sticking of the float The metering tube Borosilicate glass and related parts may be cleaned with any solvent which does not attack glass 4 1 4 2 Section 4 Maintenance Models 1350E and 1355E THIS PAGE WAS INTENTIONALLY LEFT BLANK Installation and Operation Manual X VA 1350E eng Part Number 541B082AAG April 2009 Installation and Operation Manual Section 5 Parts List X VA 1350E eng Part Number 541B082AAG April 2009 Models 1350E and 1355E 5 1 General When ordering parts please specify Brooks Serial Number Model Number Part Number Description and Quantity Refer to Figure 5 1 and Table 5 1 5 1 5 2 Section 5 Parts List Installation and Operation Manual X VA 1350E eng Part Number 541BO082AAG Models 1350E and 1355E April 20
24. rstand any of the instructions contact your Brooks Instrument representative for clarification Follow all warnings cautions and instructions marked on and supplied with the product Inform and educate your personnel in the proper installation operation and maintenance of the product Install your equipment as specified in the installation instructions of the appropriate instruction manual and per applicable local and national codes Connect all products to the proper electrical and pressure sources To ensure proper performance use qualified personnel to install operate update program and maintain the product When replacement parts are required ensure that qualified people use replacement parts specified by Brooks Instrument Unauthorized parts and procedures can affect the product s performance and place the safe operation of your process at risk Look alike substitutions may result in fire electrical hazards or improper operation Ensure that all equipment doors are closed and protective covers are in place except when maintenance is being performed by qualified persons to prevent electrical shock and personal injury All pressure equipment with an internal pressure greater than 0 5 bar g and a size larger than 25mm or 1 inch falls under the Pressure Equipment Directive PED The Directive is applicable within the European Economic Area EU plus Norway Iceland and Liechtenstein Pressure equipment can be traded freely within this area
Download Pdf Manuals