Home
Product Manual
Contents
1. ALL SEASONS HIRE WARMGLOW SAFETY OPERATION amp MAINTENANCE INSTRUCTIONS FOR H029300 110V amp H029400 230V Control Doc No UI 0529 1104 Issue 01 29 11 06 IMPORTANT SAFETY INSTRUCTIONS This instruction booklet contains vital information for the safe use and efficient operation of the Rhino TQ3 Carefully read and understand all instructions before operating maintaining or cleaning the heater Failure to adhere to the instructions could result in fire electric shock serious personal injury or property damage KEEP THIS BOOKLET FOR FUTURE REFERENCE HEATER IDENTIFICATION 1 Heater Cassette 4 Heater Body 2 Safety Guard 5 Handle 3 Wheels for easy mobility 6 Switch Plate GENERAL SAFETY INFORMATION 1 Ensure power supply is correct voltage for heater by checking the Rating Plate on the rear of the heater cassette 2 Ensure infrared lamps are correct voltage i e 110V power input 110V lamp 230V power input 230V lamp check Rating Plate as above NOTE Using infrared halogen lamps of different voltage to the heater can increase risk of damage to heater or personal injury Replace damaged power cord immediately Replace damaged reflectors or safety guard immediately Refer all servicing of electrical parts to a qualified electrician 6 Protect power cord from contact with sharp objects chemicals or hot surfaces 7 This product is designed for indoor usage only and should not be
2. e return the heater to a standing position as described in the Caution section e check lamps are inserted correctly into lamp holders ensuring cooling time has been adhered you may need to remove the safety guard see Installation of Infrared Halogen Lamp e if no damage has occurred to lamps or lamp holders replace safety guard if applicable re connect power cord to the power supply and switch the heater back on In the event of the 230V heater being knocked over a safety cut out switch which activates at an angle of 35 10 will disable the heater Follow above steps to re start the heater Should the power cord require replacement a complete wiring loom should be purchased and fitted by the manufacturer his agent or a suitably qualified person in order to avoid a hazard IMPORTANT THE MINIMUM SAFE DISTANCE FOR THE HEATER FROM ANY OBJECT MATERIAL OR SURFACE IS 2M THIS MUST BE ADHERED TO AT ALL TIMES INSTALLING INFRARED HALOGEN HEATER LAMPS 1 Ensure that the lamps are e the correct voltage rating for the power input i e 110V power input 110V lamp e maximum of 1 4kW 2 Remove safety guard on front of heater cassette by loosening and removing all 5 screws and lifting guard in an upward direction 3 Remove tube from outer packaging carefully leaving it in its protective wrapping see About The Infrared Halogen Lamps on page 2 Expose the end caps of the tube and insert one end into one of
3. place any object on the safety guard of the heater cassette at any time 14 Do Not use this heater with a thermal programme control timer or any other device that switches the heater on automatically as a fire risk exists if the heater is accidentally moved or covered 15 Do Not leave the heater unattended at any time whilst switched on INSPECT YOUR NEW HEATER The package should include the following items which should be removed from the packaging carefully and inspected for damage Rhino TQ3 Radiant Halogen Heater with power cord plug amp 2 x 1 4kW infrared halogen heater lamps GENERAL OPERATIONAL INFORMATION The Rhino TQ3 may be used with an electrical supply of 110V or 230V dependant on the model see Rating Plate If your model is the 110V variant Rhino recommend the use of the Defender 3 0kVA Heater Transformer with 32A outlet Part No E205062 The maximum permitted lamps are 2 x 1 4kW For lamp fitting refer to Installation of Infrared Halogen Lamp on page 2 The heater can be operated with either one lamp or both lamps illuminated as desired but ensure two lamps are fitted at all times oo gt IMPORTANT DURING RELOCATION THE HEATER SHOULD REMAIN SWITCHED OFF AND DISCONNECTED FROM THE POWER SUPPLY The 110V heater is designed for industrial use only Should the heater be knocked over e switch off the heater at the on off switches e disconnect the power cord from the power supply
4. nd a soft cloth Do Not touch a lamp just after switching off its power supply Temperature of a halogen lamp surface can exceed 600 C during its operation ELECTRICAL TEST MAINTENANCE amp STORAGE 110V 32A BS 4343 WARNING THIS IS A CLASS 1 TESTED APPLIANCE BS 60309 l 230V 13A UK 3 pin e When earth bond testing the readings should be 0 10MQ BS 1363 A with 13A and below Ea fuse BS 1362 e Do Not perform a flash test as this will reduce the life of 110V Yellow 3G 4 0mm the lamps HO7 VV F e Do Not use abrasive cleaners or polishes POWER CORD 230V Black 3G 1 5mm e Always switch off disconnect the heater from the power H07 RN F supply and allow cooling for recommended time before DIMENSIONS LxWxH Heater cleaning Clean the heater with a damp cloth cassette in upright position inc 500 x 460 x 1000mm e When not in use store in a dry suitable environment wheels amp cass adj knob preferably in the original carton to prevent damage WEIGHT 14 3Kg OPERATING n n TROUBLE SHOOTING FAULT DESCRIPTION SUGGESTED SOLUTION Check power supply HEATER DOES Check lamp s for damage NOT OPERATE or misalignment Check all wiring connections Consult a qualified electrician OTHERS or contact Rhino contact details opposite SPECIFICATION DATA 110V H029300 PART NUMBER 230V H029400 POWER REQUIREMENT 110V or 230V 50Hz INFRARED HALOGEN Wattage 2 x 1 4kW 5 LAMP Overall Leng
5. rt the BROWN live core into the terminal connected to the fuse housing and finger tighten screw e Insert the BLUE neutral core into the terminal to the bottom left of the live terminal and finger tighten screw e Insert the YELLOW GREEN earth core into the top centre terminal and finger tighten screw 5 Ensure all copper wire is fully inserted into correct terminal positions before fully tightening all terminal screws 6 Clamp the strain relief over the outer insulation of the power cord leaving at least 3mm of insulation above the strain relief on the exposed three cores side and fix in place with the two screws 7 Push the plug rear cover together with plug housing and fully tightened the single centre screw If requirement is for a 230V 16Amp or 32Amp Blue Plug ensure conformity to BS 60309 For wiring instructions please follow 110V wiring instructions where relevant ABOUT THE INFRARED HALOGEN HEATER LAMPS Rhino recommends the use of Toshiba Infrared Halogen Heater Lamps Slim Ruby type with this product obtainable from Rhino Do Not touch halogen lamp quartz glass with bare hands Quartz tube material could deteriorate by salt to lose mechanical strength Sweat on fingers contain salt components and have unfavourable influence on quartz tubes Hold the tube using the protective wrapping provided in its package or with a piece of clean dry cloth If the tube glass surface is touched clean cold tube with alcohol a
6. th 349mm 110V amp 230V Average Life 5000Hrs POWER CORD LENGTH 3 Metres
7. the lamp holders Push tube carefully against lamp holder until other end of tube can be lowered into other lamp holder Remove protective wrapping from lamp Repeat steps 4 and 5 for other lamp Replace safety guard by locating the 3 slots on the bottom of the guard and secure all 5 screws Do not over tighten REPLACEMENT PLUG WIRING INSTRUCTIONS In the event of the plug requiring re wiring or replacing please follow these instructions 110V Rhino recommend the use of a 32Amp Yellow Plug that conforms to BS 60309 1 Unscrew the screws holding the plug rear cover with the yellow plug housing and pull apart 2 Insert a suitable power cord as recommended in General Operational Information on page 1 through the rear cover 3 Loosen the two screws on the strain relief situated on the rear of the yellow plug housing and remove it 4 Strip the outer power cord insulation approx 50mm to expose the three cores 5 Reduce the live and neutral cores by 10mm to ensure the earth core is 10mm longer 6 Strip the insulation of the three cores approx 10mm to expose the copper strands i 40mm oo e Insert the BROWN live core into the correct terminal manufacture symbols may differ and loosely tighten both screws e Insert the BLUE neutral core into the correct terminal manufacture symbols may differ and loosely tighten both screws e Insert the YELLOW GREEN earth core into the correct terminal manufact
8. ure symbols may differ and loosely tighten both screws 7 Ensure all copper wire is fully inserted into correct terminal positions before fully tightening all terminal screws 8 Clamp the strain relief over the outer insulation of the power cord leaving at least 5mm of insulation above the strain relief on the exposed three cores side and then fix it in place with the two screws 9 Push the plug rear cover together with yellow plug housing and fully tighten with the 2 screws Do not over tighten 230V Rhino recommend the use of a 13Amp UK 3 Pin Fused Re wireable Plug that conforms to BS 1363 A IMPORTANT IF USING THE 13AMP FUSED PLUG A 13AMP FUSE CONFORMING TO BS 1362 MUST BE USED 1 Unscrew the single centre screw holding the plug rear cover with the plug housing and pull apart 2 Loosen the two screws on the strain relief situated on the rear of the plug housing and remove it 3 Using a suitable power cord as recommended in General Operational Information on page 1 strip the outer power cord insulation as recommended on the plug wiring card or on the underneath of the plug housing itself to expose the three cores IMPORTANT Ensure that the YELLOW GREEN earth core is the longest of the three cores to ensure that it will be the last to be pulled out in the case of excessive force applied to power cord 4 Strip the insulation of the three cores approx 6mm to expose the copper strands e Inse
9. used outdoors near or immersed in water Tee 8 Ensure no object material surface is within the minimum safe distance see General Operational Information 9 If an extension power cord is required use maximum of one only 14 Metre 3G 4 0mm for 110V or 3G 1 5mm for 230V The extension power cable must be fully unwound Ensure that correct variant is used CAUTION 1 Ensure that heater body is positioned on a firm horizontal dry surface 2 Keep away from flammable objects materials surfaces This product gets very hot during use Mount or use ina location where accidental contact particularly by children is unlikely 3 Ensure on off switches are set to off before connecting power cord to power supply Do Not move heater whilst switched on Do Not move heater by pulling on power cord Do Not remove plug from mains supply by pulling on power cord 7 Always switch off heater disconnect from power supply and allow cooling for at least one hour before attempting to touch heater cassette or lamps 8 Do Not remove safety guard whilst heater is switched on Turn off and allow cooling as above before servicing 9 Do Not operate heater without safety guard 10 Do Not operate heater without lamps 11 Do Not operate heater if cassette is not locked in one of the three pre set directional positions see Adjusting Heater Cassette Direction 12 Do Not look directly at illuminated lamp s 13 Do Not
Download Pdf Manuals
Related Search
Related Contents
平成 26年度版 浄化槽普及促進ハンドブック System Area Manager User Manual SERVICE MANUAL tex500-lcd & tex1000light - RVR Elettronica SpA Documentation Blackboard Student Manual the User Manual Document Copyright © All rights reserved.
Failed to retrieve file