Home
25320 P-IR remote control
Contents
1. P IR Remote Programming Adjust your desired values by cursor buttons Press and hold open lock button for 2 seconds while pointing at the detector to enter the detector s programming mode red LED flashing Values may be applied to the detector by pres sing the SEND or OK button After receiving the new values the detector quits programming mode immediately While pres sing any button the control LED will light up While the detector receives a command the will flash LED three times Attention mechanical adjustment to potentiometers as well as remote control commands will only be ac cepted during automatic mode De tector is operational one minute after connecting to mains power light will be permanently ON during warm up unless detector is set to impulse mode Automatic mode is factory default If mains power is interrupted for 0 5 sec or more detector will be put into warm up mode Any adjusted values and modes will remain intact after a power interruption Readjusting the LUX and TIME po tentiometers will override any remote control settings detector LED fla shing three times Either potentio meter values or remote control com mands may be active at any one ti me Mixing values between remote control and potentiometers is not possible exception lux learn function Commissioning Control LED SEND Sends preselected parameters shown in display to the detector DISPLAY Shows
2. cted light for 10 seconds read in the current ambient light value and store it as threshold lux value Adjusted lux value applied by remote control or potentiometer will be overwritten existing SENS TIME values will remain unchanged OK Sending and storing parameters to detector SENS TIME LUX TEST Puts detector into test mode After each detection detector will switch for 4 to 5 seconds Mode will be quit automatically after 2 minutes or anytime by pressing the ON OFF or AUTO buttons AUTO Automatic function default ON Lights permanently on OFF Lights permanently off mode is active during 6 hours after which the detector switches back into automatic mode If TIME is set to impulse ON cannot be activated The factory default setting for sensors is 6 minutes and 50 lux Remove the foil to activate the battery Press the PLAY button to check factory settings Use cursors to adjust default values Recommended setup in a corridor SENS 8 m max TIME 6 min LUX min Removing the battery from the device is recommended should the remote control not be used for a longer time period Technical data Power Operation range Dimensions 3V Battery CR 2025 4 to 6 m max direct view 55 x 85 x 10 mm Do not dispose of electrical appliances in your waste bin use the collecting point of your municipality or return the old device to your dealer cE Z blin
3. preselected values Attention standard values The values on the detector itself may vary consider ably depending on detector type its position and location CURSOR Up down navigation between parameters SENS TIME LUX left right will change the value PAUSE Press this button briefly to set the pause between two impulses to 20 or 60 seconds The command will be sent directly to the detector To change the impulse pause the detector needs to be put into impulse mode Pause setting 20 second 1 beep 60 seconds 2 beeps can only be set by remote PLAY Preselected values are shown on display in sequential order Holiday mode If ambient light falls below 10 lux light will be permanently turned on for 4 hours After 4 hours sensor will be set back to automatic mode Deactivation via ON OFF AUTO buttons WARNING This function must not be used if staircase timer switches are connected Activating opening programming mode Press and hold this button for 2 seconds to put the detector in programming mode Settings may now be sent to the detector by remote control After the settings have been confirmed the detector will exit program ming mode immediately 2 sec or after 5 minutes Deactivating closing programming mode This button closes programming mode without applying new settings Lux learn function During activated programming mode press and hold this button for 2 seconds The detector will turn off the conne
Download Pdf Manuals
Related Search
Related Contents
embc1000-usb429-42 user manual APEX PROFILER USER MANUAL Samsung WP10 Uživatelská přiručka Manuale Utente - M.System di Morandi Marcello Sharp EL-6050 Owner's Manual RACK PAL INSTALLATION MANUAL 取扱説明書 - ノヴァ電子 MARAZZI UG99 Use and Care Manual FALC-11PCアプリインストール説明書(130221) Copyright © All rights reserved.
Failed to retrieve file