Electronic Code Locks SL2000B v1.4 and SL2000S1K v1.3

image

Contents

1. If an illegal operation occur during Memory Reset the device will signal an error long beep and will return to the beginning of the programming so you can start to enter the C1 C10 digits once again The Memory Reset procedure automatically comes to an end when the last C10 digit is entered The device stores the configuration as well as all codes in a nonvolatile memory which can be reprogrammed whenever required After the Memory Reset procedure comes to an end all codes are set to factory default values see section below Default Codes Example The following digits C1 C10 were entered during the Memory Reset procedure 0 1 LO 2 L3 E3 E1 O L2 3 This sequence sets the following options e Delay before Door Lock open 01 second e Door Lock open time 02 seconds e Time to close the door 33 seconds e Reprogramming of the MASTER code disabled e Reprogramming of the INSTALLER code enabled e Option 1 Timed Lock out off e Option 2 Disable USER Codes When in Armed Mode off e USER codes length 6 digits e MASTER and INSTALLER codes length 10 digits Default settings After the Memory Reset is accomplished SI2000 restores following codes MASTER Code All digits are 1 1111 the length of the code depends on the C10 parameter entered later during Memory Reset procedure Strona 7 z 13 roger Electronic Code Locks SL2000B v1 4 and SL200S1K v1 3 EN Rev C doc 2011 11 16 INSTALLER Code All digits are 2
2. 2222 the length of the code depends on the C10 parameter entered later during Memory Reset procedure USER Code noO1 All digits are 3 3333 the length of the code depends on the C9 parameter entered later during Memory Reset procedure All USER codes 02 55 All USER codes no 02 55 are blank they doesn t exist Installation e he SL2000 code lock should be mounted near the supervised door on a vertical piece of supporting structure e he SL2000S1k can be installed either indoor or outdoor location SL2000B can be installed in indoor location only e Assure that the surface beneath of the controller s rear panel is flat and smooth e Disconnect power supply before making any electrical connections e Once installed and electrically connected the unit has to be properly programmed e When forgotten MASTER and INSTALLER codes can be restored to their default values and then programmed again e Use separate pair of wires to supply door lock and SL2000 code lock e tis forbidden to supply the door lock directly from the DC input terminals of the code lock e Always add the silicon diode e g 1N4007 in parallel to the door lock note that diode must be located as close as possible to the door lock terminals e Do not attempt to use REL1 output for switching of voltages higher then 24V DC AC gummmmmmmmmmmmmmmmmmmmmmmmmmmmmmm I Power supply Door lock wiring Strona 8 z 13 roger Ele
3. Fax 48 55 272 01 33 Technical support PSTN 48 55 267 01 26 e mail support roger pl Web www roger pl Strona 13 z 13 roger
4. 0S1K v1 3 EN Rev C doc 2011 11 16 Configuring the SL2000 Memory Reset In order to configure the SL2000 you must perform the Memory Reset procedure and then enroll sequentially 10 digits C1 C2 C10 which will configure the unit for the individual installation After the Memory Reset the entire code lock memory is erased including all codes and initialized with default factory settings In order to perform Memory Reset do the following steps e Turn off the power supply e Put the jumper on JP1 contacts PZ3 in SL2000B e Turn on the power supply e Wait till the moment when SL2000 will generate three series of two beeps xx this signal indicates that unit has erased memory and restored default configuration parameters e Remove jumper from JP1 contacts PZ3 in SL2000B e Enter sequentially ten digits from C1 to C10 e Once the last digit C10 is entered the code lock generates three series of two beeps and automatically switches to normal work it enters Armed mode Meaning of the configuration parameters C1 C10 C1C2 Specifies the time delay from a moment when USER code is entered till moment when Door Lock output will be triggered It can be programmed from 00 to 99s default 04 C3C4 Specifies the time for which Door Lock output will be activated It can be programmed from 02 to 99s default 04 C5C6 Specifies the time within door must be closed otherwise Door Alarm will occur The C5C6 time is s
5. Electronic Code Locks SL2000B v1 4 and SL2000S1K v1 3 Document version Rev C CE A oH zu Beer i us os Y j 5 1 x 1 A X j B Hi 1 M j 7 Y 5 H 1 t i i 7 t l Hi 1l f il 1 S 4 1 1 1 TITTEN TIERE M Oa N aee eae mi rap e i a e Roger Sp j Electronic Code Locks SL2000B v1 4 and SL200S1K v1 3 EN Rev C doc 2011 11 16 Features e Bell output to indicate Door Bell and Door Alarm e Bistable Switch output to control door locking device e DC input for detection of door status e DRinput to unlock the door from the external button e INSTALLER code for programming e MASTER code switch between armed and disarmed modes e 55 USER codes for door unlocking e Programmable length of codes e User indexing for easy administration of the codes e Nonvolatile memory e Three LEDs and buzzer e Tamper e 12VDC supply e CE Introduction The SL2000 electronic code lock is dedicated to operate as a stand alone door access control unit It is equipped with one relay output two transistor outputs and three inputs All codes and parameters programmed to device are stored in nonvolatile memory SL2000S1K is located in metal enclosure and can operate in outdoor locations Functional Description Note The C1 C2 C10 parameters which appear in this manual refer to the configuration parameters programmed to the SL2000 during Memory Reset procedure for details see section Configuring th
6. ctronic Code Locks SL2000B v1 4 and SL200S1K v1 3 EN Rev C doc 2011 11 16 CEE aN9 Note Bistabilne output is described as SWITCH SWITCH Bistable 3d AdWVL Dad pep mecs O View of PCB security lock SL2000B Uu Oo al Iv ZZ o ON WWOD mag Position of housing holes E Optional n flush mounting 1 o box i 60 mm View and installation diagram cdri46 Strona 9 z 13 roger Electronic Code Locks SL2000B v1 4 and SL200S1K v1 3 EN Rev C doc 2011 11 16 CEP oma cis IGIENE m cmo d j Led CLOSE LED indicator d j Led OPEN 12VBISTABLETAMP DC NO DR I SISISI si si sis sso Led ENTRANCE a hn ener peser umi eee pese eem emu umm View of PCB security lock SL20001SK Steel body and keypad Electronic module molded with synthetic resin 118 5 mm View and installation diagram Cdri45 Strona 10 z 13 roger Electronic Code Locks SL2000B v1 4 and SL200S1K v1 3 EN Rev C doc 2011 11 16 Power Supply e g PS10 PS20 Supply Warning device or Door Bell Door Alarm and Door Bell output Tamper loop Door Contact NO type Exit Button NO type x o 2 pes o o Q J Typical wiring of SL2000 code lock Cdri44 Strona 11 z 13 roger Electronic Code Locks SL2000B v1 4 and SL200S1K v1 3 EN Rev C doc 2011 11 16 Connection assignments OR Ext Buttoninput NOE BELL Transistor output 1A 15V DC BISTABLE Transis
7. e SL2000 later in this document Output SL2000 has one relay output and two transistor outputs Bistable Switch i Bell Relay output The REL output offers one switched NO NC contact rated 1 5A 30V AC DC This output is activated each time a user code sequence is entered User code 01 55 Activation takes place after a C1C2 delay and lasts for the time specified by the C3C4 parameter Each time the RELAY switch of SL2000 lock is activated the yellow led ENTRANCE lights up By using the Main code it is possible to temporary disable enable activity of all user codes Disable USER Codes When in Armed Mode Open collector outputs The Bistable Switch in SL2000B and BELL outputs of SL2000 lock are an open collector transistor type Some care must be taken in order to protect them from damage When transistor output is switched off it remains in high impedance state when switched on it shorts connected to it potential with supply minus The maximum current must not exceed 1A and maximum voltage must not exceed 15VDC Strona 2 z 13 roger Electronic Code Locks SL2000B v1 4 and SL200S1K v1 3 EN Rev C doc 2011 11 16 Bistable Switch output Enter the master code each time switches output in the opposite state This mode is dedicated to control some device or system which requires bistable latch control usually it can be used to control arming mode of the alarm zone or entire alarm system The Status output can be used for rearming of a
8. er the Door Lock momentary output Each time a valid USER code is entered the SL2000 starts counting C1C2 time delay and then activates Door Lock output for time defined by the C3C4 parameters The USER codes can be 2 8 digits long Note The SL2000 enables programming of maximum 55 USER codes each of them can be used to trigger Door Lock output Strona 4 z 13 roger Electronic Code Locks SL2000B v1 4 and SL200S1K v1 3 EN Rev C doc 2011 11 16 Commands Commands can be entered during normal working time of a SL2000 and doesn t require entry to the programming mode USER Code 72 Whenever a valid USER code is entered the code lock generates two beeps and then starts count C1C2 time delay After it passes SL2000 activates Door Lock momentary output for the time defined by C3C4 settings MASTER Code 72 Each time the MASTER code is entered the SL2000 changes its arming mode switches from Armed to Disarmed mode or in reverse direction INSTALLER Code After this command code lock generates two beeps and enters the Installer Programming mode In this mode installer can manage add modify or delete the USER codes Old INSTALLER Code New INSTALLER Code This command erases the current INSTALLER code and program a new one If command is successfully accomplished the unit generates three series of two beeps Old MASTER Code X Old MASTER Code This command erases t
9. he current MASTER code and program a new one If command is successfully accomplished the unit generates three series of two beeps Note Whenever you re program MASTER or INSTALLER code remember that new code programmed into a unit must have the same length as the old one Normally pressing is used to mark the end of the code but when pressed separately for a time longer the O 5s it triggers Door Bell indication Programming The USER Codes The SL2000 enables programming of up to 55 different USER codes The USER codes can be managed added deleted changed only in the Installer Programming mode to enter Installer Programming mode press INSTALLER Code Once in the Installer Programming mode you have following commands 0 1 code Z2 Programming of the USER code no 1 0 2 code Z Programming of the USER code no 2 etc us et etc 5 5 code Z Programming of the USER code no 55 0 0 7 Delete all USER codes 9 9 Z code 7 Deletes the code entered in square brackets Exit from the Installer Programming mode When the SL2000 accepts the new USER code it generates two series of two beeps Any attempt to program the USER code which already exists in the memory or to program it with a wrong length then will cause the programming error signaled by a long acoustic beep Strona 5 z 13 roger Electronic Code Locks SL2000B v1 4 and SL20
10. keypad s entries The end of 60 seconds lock out time is indicated by two series of two beeps Disable USER Codes When in Armed Mode If this option is enabled the SL2000 grants access only when it operates in Disarmed mode With this option active the access to the controlled door will be totally disabled unless the SL2000 will be switched to Disarmed mode again Thanks to this formula the MASTER user can disable access to the room by switching the unit to the Armed mode and vice verso he can re enable access to the controlled door by switching the lock to the Disarmed mode The SL2000 can be switched between Armed and Disarmed modes via the MASTER code only Note When the SL2000 is in Armed mode this output remains not active red CLOSE LED lights up it become active when lock works in Disarmed mode green OPEN LED mg lights up Codes The SL2000 offers three types of codes e MASTER Code e INSTALLER Code e USER Codes Each type of code is dedicated for individual purpose The length of each code can be programmed during Memory Reset procedure The entry of each code must be followed by the key which is used to mark the end of the code MASTER Code The MASTER code is used to switch the SL2000 between Armed and Disarmed modes it can be 4 10 digits long INSTALLER Code The INSTALLER code is required to enter the Installer Programming mode it can be 4 10 digits long USER Codes These codes are used solely to trigg
11. n alarm zone or to control any other device or system which requires the ON OFF method of control Bell output Normally this output remains in high resistance state if triggered it shorts to supply minus GND The Aux output has been designed to indicate two situations e Door Bell event e Door Alarm event Whenever the Bell key is pressed for a moment or the key is pressed and held down longer then half a second the Aux output goes steady on shorts to supply minus the Aux output remains in this condition as long as the Bell or 4 key is being pressed The Aux output can be also activated when Door Alarm is active The code lock indicates the Door Alarm through pulsed modulation of the Aux output Thanks to this feature steady or pulsed output operator may distinguish the Bell signal from the Door Alarm The maximum current sink by this output is internally limited to 1 0A the maximum voltage applied to it must not exceed 15VDC Normally the Aux output is used to trigger some kind of warning device e g alarm siren or buzzer Door Alarm The Door Alarm will occur when e door has been opened without entering of a valid USER code e door has been opened without pressing of the Exit Button e door has not been closed within designated time defined by the C5C6 configuration settings Once started the Door Alarm is indicated by the pulsed signal on BELL output which is accompanied by a the continues acoustic sound generated by the i
12. nternal buzzer Pressing any key will cease the acoustic signal however this does not cancel the alarm indication on the BELL output The alarm indication on this output disappears when door becomes closed or automatically after 60 seconds from the moment when alarm arose Note The Door Alarm has higher priority than Door Bell When two of these events occur simultaneously SL2000 indicates Door Alarm only because it has higher priority then Door Bell indication Inputs Input DR Exit Button Triggering of this input activates Door Lock momentary output on the same rules as entry of the valid USER code The Exit Button is a NO type input it becomes triggered when shorted to supply minus GND Input DC Door Contact This input is dedicated for the connection of a door open sensor When input is open or left unconnected the code lock assumes that door is closed when input is shorted to supply minus GND the SL2000 assumes that door is open Strona 3 z 13 roger Electronic Code Locks SL2000B v1 4 and SL200S1K v1 3 EN Rev C doc 2011 11 16 Note If you are not going to use a door open sensor leave the Door Contact input unconnected Without a door open sensor the SL2000 will not signal the Door Alarm Special options Timed Lock Out If this option is enabled the SI2000 disables the keypad for 60 seconds after three attempts of entry of the incorrect code After this time the SL2000 re enables the keypad and is ready to accept new
13. tarted from the moment when C4C4 time has passed by It can be programmed from 00 to 99s the 00 value sets unlimited time for door closing default 09 C7 Enables or disables of reprogramming of the MASTER and INSTALLER codes enter O 3 default 0 C7 Reprogramming of the MASTER Reprogramming of the INSTALLER code code o Enabled Enabled Disabled Enabled Enabled Disabled Disabled Disabled Note If reprogramming of a given code is disabled the SL2000 allows you for a single attempt only to program of the given code Once the code is programmed you will not be able to change it unless the Memory Reset is carried out Use this function to disable the end user to change your MASTER and INSTALLER code Strona 6 z 13 roger Electronic Code Locks SL2000B v1 4 and SL200S1K v1 3 EN Rev C doc 2011 11 16 C8 Enabling and disabling special options enter 0 3 default O Option 1 Timed Lock out Option 2 Disable USER Codes When in Armed Mode D Disabled Disabled Enabled Disabled Disabled Enabled Enabled Enabled C9 Defines the length of the USER codes enter 0 3 default 1 0 USER codes are 2 digits long I USER codes are 4 digits long 2 USER codes are 6 digits long aU USER codes are 8 digits long C10 Defines the length of the MASTER and INSTALLER codes enter 0 3 default 1 0 Both codes are 4 digits long i Both codes are 6 digits long 23 Both codes are 8 digits long 25 Both codes are 10 digits long
14. tor output 1A 15V DC SWITCH REL REL COM Relay output 1 5A 24V DC AC REL E REL NC Technical Specification Parameter Value Supply 2 10 15 VDC C e consumption Avg 25 mA Q 12V DC Max 80 mA 15V DC with relay output active Anti sabotage protection Tamper NC contact 50mA 24V Environmental Class SL2000B Class II input temp 10 C 40 C relative humidity O 75 SL2000S1K Klasa IV outdoor general temp 25 C 60 C relative humidity O 95 Dimensions W x S x G SL2000B 105 X 104 X 30 mm SL2000S1K 118 X 100 X 43 mm Weight SL2000B 130g SL2000S1K a H Approvals 00 Ordering Information SL2000B Plastic enclosure indoor installation only SL2000S1K Vandal proof metal cover outdoor installation available Strona 12 z 13 roger Electronic Code Locks SL2000B v1 4 and SL200S1K v1 3 EN Rev C doc 2011 11 16 Product History The symbol of a crossed through waste bin on wheels means that the product must be disposed of at a separate collection point This also applies to the product and all accessories marked with this symbol Products labeled as such must not be disposed of with normal household waste but should be taken to a collection point for recycling electrical and electronic equipment Recycling helps to reduce the consumption of raw materials thus protecting the environment Contact Roger sp j 82 400 Sztum Gosciszewo 59 Tel 48 55 272 01 32