1. C 0 8 C at 37 C Accuracy 0 1 C 0 1 C Alarms Visual Safety Lamps Visual Safety Lamps Capacity Volume 156 m 5 5 cu ft 156 m 5 5 cu ft Shelves Supplied Shelf Dimensions Total Shelf Capacity Dimensions 2 stainless steel 47 x 47 cm 18 5 x 18 5 in 10 kg 22 Ibs 2 stainless steel 47 x 47 cm 18 5 x 18 5 in 10 kg 22 Ibs Interior Width x Depth x Height Exterior Width x Depth x Height Shaking Mechanism 48 3 x 48 9 x 59 7 cm 19 x 19 25 x 23 5 in 72 4 x 73 6 x 106 7 cm 28 5 x 29 x 42 in 48 3 x 48 9 x 59 7 cm 19 x 19 25 x 23 5 in 72 4 x 73 6 x 106 7 cm 28 5 x 29 x 42 in Motor Speed Sample Controller Stroke Length Orbit Diameter Shaking Capacity stroke limited Door Switch Platform Dimensions Refrigeration Brushless DC 30 to 400rpm 4 rpm 1 rpm increments Microprocessor Digital LED 1 3 1 9 2 54 cm 0 5 0 75 1 0 in 12 mm 19 mm or 25 mm 10 kg 22 Ibs Yes 44 x 44 x 1 9 cm 17 25 x 17 25 x 75 in Brushless DC 30 to 400rpm 4 rpm 1 rpm increments Microprocessor Digital LED 1 3 1 9 2 54 cm 0 5 0 75 1 0 in 12 mm 19 mm or 25 mm 10 kg 22 lbs Yes 44 x 44 x 1 9 cm 17 25 x 17 25 x 75 in Compressor Type NA 1 6 HP Refrigerant NA R 134A 6 5 oz Electrical Watts Amps 110 120V 850 watts 8 5A 1100 watts 11 5A Watts Amps 208 240V 850 watts 5 5A 1100 watts 6 5A Cycle
2. For your own safety do not plug the unit into a power source until you have read and understood the safety and operational instructions in this manual To connect the unit to a power source 1 Be sure the plug and the cord are in good condition If the power cord is worn cut or damaged in any way do not use it Contact customer service for a replacement power cord For information on contacting customer service see page 20 2 Plug the service cord firmly into a grounded electrical outlet If the plug does not fit the outlet have a proper outlet installed by a qualified electrician SHEL LAB SI6 SI6R Shaking Incubator Operational Manual Operating the Unit Control Panel Overview Before turning the incubator on for the first time take a moment to familiarize yourself with its controls and features Following is an overview of the control panel 1 Main temperature control Displays current chamber temperature e Controls temperature set point and calibration 2 Shaker Speed RPM Control e Displays shaker platform speed Controls the rotational speed RPM of the shaker mechanism 3 Oscillation timer Permits timed shaking at a preset RPM 4 Over Temperature Protection Provides backup protection for the main temperature control e Keeps the chamber temperature from inadvertently rising above the set point 5 Alarms Error status lights and an audible alarm immediately alerts you to deviatio
3. Phase Certifications 50 60 Hz Single Phase CE 220V only 50 60 Hz Single Phase CE 220V only Weight Net Weight 90 kg 198 Ibs 114 kg 250 Ibs Shipping Weight 118 kg 260 Ibs 136 kg 300 Ibs 22 Copyright 2002 Sheldon Manufacturing All rights reserved All specifications and features for this product are subject to change without notice SHEL LAB SI6 SI6R Shaking Incubator Operational Manual WIRE DIAGRAMS SSI5 S16 110V 9851457 2800502 BLUE EMI FILTER INLET 4200505 l BLACK WHITE BLACK YELLOW BROWN l 120V 240V TO 90V STEP DOWN TRANFORMER I MER SWITCH 8350509 i 1 f l i f i 7850553 i 1 YELLOW l il Yl D EEE EEE a a a a a a MAIN TEMP DISPLAY RPM DISPLAY TIMER DISPLAY eb snow onanae CONTROL 1750791 1750788 1750679 MOTOR N BOARD 7 l 1750786 DOOR SWITCH ORANGE Renn is RPM SWITCH 7850553 vane SSE mmEVALVE ER ey SRE E P FERRITE BEAD pias 7830500 OTP tem ATEA ALARM BOARD 1 Pea 1750681 MOTOR y 4880514 lt oc fo RED _OTL 1750862 RED F I O O 1 2 17 19 800W it CHAMBER FAN 4880569 BROWN POWER INDICATOR SSN is 4650554 BLUE BROWN OUTLET 4200518 LIGHT SWITCH p BROWN 7850553 UOR T l 4660528 LAMP HOLDERS 4660502 23 Copyright 2002 Sheldon Manufacturing All rights reserved All
4. 7 Let the chamber dry out fully before replacing the removed parts or reattaching the unit to a power supply Control Maintenance The main temperature controller over temperature protection thermostat and main temperature probe do not require any maintenance If the unit appears to be having trouble maintaining a temperature see Troubleshooting on page 15 SHEL LAB SI6 SI6R Shaking Incubator Operational Manual Troubleshooting Solving Problems Should the proper function of your unit come into question use this section to help you determine what the problem is and how to fix it Check if your question is similar to those listed below Then follow the guidelines found in that section e The temperature control inside the unit does not appear to be working correctly What s wrong e The refrigeration of my SSI5R SI6R does not appear to be working correctly What s wrong WARNING Replacing fuses with wrong type and value can result in serious damage to the equipment and property ONLY Replace fuses with the same type and amperage indicated on the replacement fuse labels There are no user serviceable components inside the unit Potentially lethal voltages exist Do not attempt to service your unit beyond the procedures described here See Getting Your Unit Serviced on Temperature page 21 The temperature inside the unit is difficult to control What s wrong What is the
5. For continued safe operation of your incubator always follow basic safety precautions including e Read this entire manual before using the incubator e Be sure you follow any city county or other ordinances in your area regarding the use of this unit e Use only approved accessories Do not modify system components Any alterations or modifications to your incubator may be dangerous and will void your warranty e Always plug the units power cord into a grounded electrical outlet that conforms to national and local electrical codes If the unit is not grounded parts such as knobs and controls may conduct electricity and cause serious injury Do not connect the unit to a power source of any other voltage or frequency beyond the range stated on the power rating overlay at the rear of the unit Do not modify the power cord provided with the unit If the plug does not fit an outlet have a proper outlet installed by a qualified electrician Avoid damaging the power cord Do not bend it excessively step on it place heavy objects on it A damaged cord can easily become a shock or fire hazard Never use a power cord after it has become damaged Precautions for Your Unit Observe the following additional safety guidelines for your unit Operating Conditions For optimum performance use your incubator at room temperatures between 18 and 25 C at no greater than 80 relative humidity at 25 C If you intend to operate the un
6. gentle you will need to adjust the shaking stroke and counterweight position See on page 13 Turning the Unit On The unit is equipped with an On OFF switch that controls power to the entire unit The switch is lit by a green light when the power is on To turn the unit on 1 Be sure the unit is plugged in 2 Push the Power switch to the On I position SHEL LAB SI6 SI6R Shaking Incubator Operational Manual 3 When you turn the unit on for the first time use a screwdriver or coin to turn the Safety Temp knob fully clockwise to its maximum position This deactivates the Over Temperature Protection OTP feature For more information on the OTP see on page 12 Setting the Chamber Temperature You raise or lower the temperature in the chamber using the main temperature controller which consists of a digital display and UP and DOWN arrow pads marked Set Temp To set the chamber temperature e To set temperature press and release either up or down key and display will blink Then press and hold either up or down key to scroll up or down for set point When you press either the Up or Down arrow key the display starts to blink from bright to dim and shows the temperature set point which is the temperature to which the unit will stabilize The incubator accepts the new set point after you release the arrow pads for 5 seconds At that time the display stops blinking and indicates the present chamber temperatur
7. hand counterweight stud 1 2 5 cm Stroke Setup Vigorous Shaking right hand counterweight stud SHEL LAB SI6 SI6R Shaking Incubator Operational Manual Interior Accessory Outlet This unit features an accessory outlet to provide power for equipment such as magnetic stirrers rockers etc The weight of this equipment should not exceed 22 pounds 10 kg per shelf This equipment may provide additional heat that could affect the temperature range of this incubator We recommend testing the incubator and any accessory equipment to ensure that the desired operating conditions can be met Caution This incubator operates at conditions that might damage accessory equipment Verify that your accessory equipment is capable of operating under the same conditions as the incubator The outlet is located inside the incubator in the upper right rear of the chamber The voltage available at the accessory outlet is the SAME as the voltage supplied to the incubator For example a 120 vac incubator will have 120 vac at the accessory outlet and a 240 vac incubator will have 240 vac at the accessory outlet DO NOT exceed 500 va rating of the accessory outlet 14 SHEL LAB SI6 SI6R Shaking Incubator Operational Manual Maintaining the Unit The only regular maintenance required for your unit is to keep it clean and free from contamination Use the guidelines and instructions in this section to maximize the life of your incubator a
8. problem Possible Causes To solve the problem The temperature indicated by the Main Temperature Control is higher than my reference Controller is calibrated too high 1 Calibrate the Main Temperature Controller See page 11 thermometer 2 Call customer service See page 21 Display reads HI or 400 Probe is unplugged 1 Be sure the temperature probe is properly plugged in Or If this doesn t solve the Wire to the probe is broken prooem Call customer service See Or page 21 Probe is plugged in backwards Chamber temperature spikes over e _ Unit is not calibrated 1 Calibrate the Main the set point properly Temperature Controller See page 11 The temperature indicated by the e The temperature inside the 1 Wait for the temperature Main Temperature Control is unit has not yet stabilized indicated by the Main lower than my reference after the door has been Temperature Controller to thermometer opened stabilize If you have just Or turned the unit on wait 24 tog hours for the incubator to The temperature inside the stabilize at a warmer unit has not yet stabilized temperature A fluctuation of after the unit has been no more than 0 1 C is turned off or a power failure normal Or If this is not the problem e Controller is calibrated too 2 Recalibrate the Main low a Or Temperature Controller See page 11 16 SHEL LAB SI6 SI6R Shaking Incuba
9. serial number Record this information on the space provided on page 20 Getting Your Unit Serviced for easy future reference SHEL LAB SI6 SI6R Shaking Incubator Operational Manual Installing the Unit Installation Overview To install your unit you need to 1 Select a suitable operating location for the unit Level the unit Sterilize the unit Install the sample tray J a E Plug the unit into a power source Selecting a Location for the Unit The operating location of your unit has a significant impact on your unit s performance and how often it must be cleaned and disinfected Use the following guidelines to select the best location for your unit CAUTION DO NOT MOUNT YOU UNIT TOA FLAMMABLE SURFACE e Operating Conditions For optimum performance use your incubator at room temperatures between 18 to 25 C 65 to 77 F and at no greater than 80 relative humidity at 25 C If you intend to operate the unit in conditions outside of these limits contact your customer service representative e Exposure Avoid exposing the unit to the following e Direct sun e High air movement such as air vents heating and cooling ducts doors and other heavy traffic areas e Extreme heat from steam radiators stoves ovens autoclaves or other sources of heat e Level Surface The unit must be located on a solid flat and level surface e Space requirements Allow a minimum of
10. specifications and features for this product are subject to change without notice SHEL LAB SI6 SI6R Shaking Incubator Operational Manual SSI5 2 SI6 2 220V 9851458 2800502 EMI FILTER BROWN BLUE BROWN BLACK YELLOW 120V 240V TO 90V BLACK WHITE BLACK VIOLET i f 1 if I I I STEPDOWN Imek TRANFORMER 1 SWITCH 8350509 1 i S EORES i I i I i l t YELLOW i o YELLOW i i i a a a a a a MAIN H TEMP DISPLAY RPM DISPLAY ER DISPLAY nab amoun oeae CONTROL 1750791 1750788 1750679 MOTOR N BOARD v 1750786 DOOR SWITCH ORANGE RSW i j no RPM SWITCH 7850553 Wikio Cao See ii TE TEMPERATURE FERRITE BEAD SENSOR 7830500 Oe _ APM INER ALARM BOARD 1750681 BODINE wh MOTOR Ww 4880514 zZz lt a fo RED OTL 1750862 RED r 71 O 1 2 68 40 750W 1 Se CHAMBER FAN 4880570 BROWN I 1 A BLUE POWER INDICATOR BROWN 4650554 BLUE BROWN BIL UF OUTLET 6100532 LIGHT SWITCH BROWN 7850553 BLUE LIGHT RAILEST ee 4660506 l UORECENTTAMP 4660528 LAMP HOLDERS 4660502 24 Copyright 2002 Sheldon Manufacturing All rights reserved All specifications and features for this product are subject to change without notice SHEL LAB SI6 SI6R Shaking Incubator Operational Manual SSI5R SI6R 110V 9851459 2800502 EMI FILTER INLET 4200505 B
11. unit and any walls or partitions that can obstruct free airflow Ice built up in the chamber The door gasket leaks The door is opened too often There s an open container letting moisture collect inside the chamber Check door seal Try to limit door opening closing Seal the container Power The unit will not turn on Power cord not firmly plugged into the outlet Or The unit or wall fuse circuit breaker has blown Or The outlet is defective Or The unit is plugged into a circuit that already has too many electrical loads Be sure the voltage and frequency specifications of the outlet are within the range stated on the power rating overlay at the rear of the unit If this does not solve the problem Check the power cord at the electrical outlet for proper fit Make sure the unit is plugged in firmly If this does not solve the problem Replace fuse circuit breaker in the unit or wall as necessary If this does not solve the problem Make sure the outlet is in proper working condition Replace if defective If this does not solve the problem Check to see what other loads are on the same circuit as the unit We recommend that you plug your incubator into a circuit separate from other equipment Call customer service See page 21 The unit fuse circuit breaker blows often Wrong fuse installed Wire is shorting out Check fuse for right ampe
12. 20 cm 8 in between the rear and sides of the unit and any walls or partitions that can obstruct free airflow Allow enough room so that the door can swing open at least 90 degrees Do not block access to the power cord circuit breaker or fuses e Cleanliness Good laboratory quality control practice is the most efficient and reliable way to keep your unit free from contamination If it is important that the interior of your unit remain sterile always pay attention to the following guidelines e Keep the air in the laboratory as clean as possible e Keep the floor around the unit clean e f the unit must be placed at the floor level use a platform such as a caster platform This facilitates movement of the unit during cleaning and allows for easier access to the back of the unit e Minimize the number of times access is made to the chamber during normal operation Each time the door is opened room air is drawn in and can lead to contamination of the unit After deciding on the location for your unit follow the installation instructions below Leveling the Unit The unit must sit level from side to side and from front to back While the unit does not have to be absolutely level each of the four feet should be in firm contact with the surface on which the incubator is to be run Install the four leveling feet in the four holes in the bottom of the unit When the feet are installed you can raise or lower a corne
13. 61010 1 2012 EN 61010 1 2010 EN 61010 2 010 2003 SHEL LAB SI6 SI6R Shaking Incubator Operational Using the Unit Safely Introduction Thank you for choosing a SHEL LAB shaking orbital incubator SHEL LAB sets the standard for quality and reliability Your unit is backed by over 30 years of design and manufacturing excellence in the scientific research and medical equipment industries Your unit is a general purpose incubator designed for professional industrial or educational use where e the preparation or testing of materials is done at approximately atmospheric pressure and no flammable volatile or combustible materials are being heated These units are not intended for use at hazardous or household locations Before you use the unit read this entire manual carefully to understand how to install operate and maintain the unit in a safe manner Your satisfaction with the unit will be maximized as you read about its safety and operational features Keep this manual on hand so it can be used by all operators of the unit Be sure all operators of the unit are given appropriate training before you put the unit in service Use the unit only in the way described in this manual Failure to follow the guidelines and instructions in this manual may be dangerous and illegal General Safety Considerations Your incubator and its recommended accessories have been designed and tested to meet strict safety requirements
14. C BROWN ORANGE a a a A a a MAIN TEMP DISPLAY RPM DISPLAY 1750791 1750788 MOTOR N BOARD l 1750786 DOOR SWITCH ORANGE 7850578 A RPM SWITCH 7850553 TEMP RATURE FERRITE BEAD SENSOR 7830500 OTP APM TIMER ALARM BOARD BODINE 1750681 MOTOR w 4880514 9 0860503 zZ lt x ac fe RED _OTL 1750862 RED 68 40 750W CHAMBER FAN 4880570 BROWN n i 1 r BLUE POWER INDICATOR BROWN e 4650554 4 BLUE BROWN BLUE OUTLET 6100532 LIGHT SWITCH BROWN 7850553 BLUE 4660528 LAMP L HOLDERS z 4660502 fae E HIGH LIMIT CUT OFF 42 C i 1750862 PAPRGERATON NDENSIN 4 ol H UNIT I 7010543 BROWN O Tan 26 Copyright 2002 Sheldon Manufacturing All rights reserved All specifications and features for this product are subject to change without notice
15. Ee RAB SSI5 SSI5 2 SSI5R SSI5R 2 Orbital Shaking Incubator Operational Manual Models SSI5 SSI5 2 SSI5R SSI5R 2 Previously designated as SI6 SI6 2 SI6R SI6R 2 4861534 11 2013 SHEL LAB SI6 SI6R Shaking Incubator Operational Manual Table of Contents Using the Unit Safely Introductions scsbaaeiebs aces le sean a E dad odeda a E land phates doit ERR General Satety Considerations ss ccs eisevcsgusdvqeasecasucsduusndesssiaesdegsaes a aa oiea eiai Preca tions tor Your WIG Soiscted sea itdatead theta itca Sah eae Sotea te a a a hs We ATI S01 SVT DONS Sosa e E EE taal oes aca eas ec ETA About this Miamiialss s iveshas he nt a t e e E Features of Your Unit Product descriptiones a a n cage thers au saa sat R A S Key Feanutes esinsin aetti ani aaas er a E EAE AAA ee ae aaa Receiving Your Unit Unpacking and Inspecting Your Unit s sssessesseesseessseeesseessesseesseresseetsseessersseesseeesseee Inspection Guidelihes cirerer eae n E E a N E Recording Data Plate Information 45 1 3 ssc0 lt icssazesesaesnceeeasedensdaavessteeooesedennsconasespbunedeasneceeses Installing the Unit Installation Ver Va Wis sescagsk ths d ccs inn daacs Leg dgacaseeead ses aE EE evssasaatasondaastdvecdaanee Selecting a Location for the Unit os dessucsetce fees teouesy tess neas scasangehdadaueeenacess wus ae ideusucyeaeeeees Bee Tinie the WEE 4552s see ea a eee aa caalga a tues Maar cage A ete eana ene es poses CONG AD Ob LOr Bp aT eran eee Re E oer g
16. If this does not solve the problem 4 Call customer service See page 21 The shaker motor squeals continuously with a constant pitch Changes in intensity only when rpm varies Stops when the oscillate switch is turned off Sound appears to be coming directly from the motor not the mechanism Motor cable plugs not seated properly Or Le May have motor bearing failure 1 May need to replace motor Perform a visual inspection on motor to decide If this does not solve the problem 2 Call customer service See page 21 Contamination The chamber is contaminated Your unit is not cleaned and decontaminated often enough Or If your unit becomes contaminated even after you follow an appropriate maintenance regimen the source of the contamination is probably not the incubator 1 See Maintaining the Unit on page 14 for recommendations and instructions on decontaminating your unit If this does not solve the problem 2 There are many sources of contamination such as water baths hoods autoclaves reagents disposables incubators and personnel If your unit becomes contaminated even after you follow an appropriate maintenance regimen the source of the contamination is probably not the incubator 3 Call customer service 19 SHEL LAB SI6 SI6R Shaking Incubator Operational Manual Getting Your Unit Serviced Getting Assistance Your incubator will provi
17. ROWN BLUE BLACK WHITE BLACK BROWN BLACK YELLOW 120V 240V TO 90V STEPDOWN l l l l l l TIMER TRANFORMER 8350509 7850553 YELLOW YELLOW a a a a a a MAIN EMP D RPM DISPLAY RED SWITCH O CONTROL 1750788 BROWN ORANGE MOTORN BOARD 1750786 ORANGE A RPM SWITCH 7850553 C5 FERRITE BEAD ica RPM TIMER ALARM BOARD BODINE 1750681 MOTOR g 4880514 2 0860503 3 lt L a fe RED OTL 1750862 RED 2 CHAMBER FAN 17 10 800W 4880569 BROWN POWER INDICATOR E 4 4650554 2 P BROWN m LIGHT SWITCH BROWN 7850553 BLUE i HIGH LIMIT CUT OFF 42 C or __ _1750862_ COMPRESSOR REFRIGERATION 4 CONDENSING UNIT 7010521 BROWN o i BROWN BLUE 1 2 25 Copyright 2002 Sheldon Manufacturing All rights reserved All specifications and features for this product are subject to change without notice SHEL LAB SI6 SI6R Shaking Incubator Operational Manual SSI5R 2 SIGR 2 220V 9851460 2800502 EMI FILTER INLET 4200505 I 3 uet fad BLACK l Ej S 1 BLACK YELLOW a Q I i z 120V 240V TO 90V S S STEP DOWN a S i TIMER TRANFORMER 3 f SWITCH 8350509 l a505 1 YELLOW H o YELLOW i CONTROL 1750679 a
18. aving our factory all units are packaged in high quality shipping materials designed to provide protection from transportation related damage Once a unit leaves our factory however safe delivery becomes the responsibility of the carrier who is liable for loss or damage to your unit Damage sustained during transit is not covered under your unit warranty When you receive your unit inspect it for concealed loss or damage to its interior and exterior Should you find any damage to the unit follow the carriers procedure for claiming damage or loss Inspection Guidelines e Carefully inspect the package for damage If the package is damaged report the damage to the carrier service that delivered the unit e f the carton is not damaged open the crate and remove its contents Verify that all of the following equipment is included with the unit e 1 shelf 5100531 e 1 sample tray 9750758 e 4 shelf clips 1250512 e 6 counter weights some of which are located in the metal pocket at the back of the unit e 4 leveling feet e Carefully check all packaging before discarding Save the unit s shipping crate until you are sure all is well If you need to return your unit for any reason see Getting Your Unit Serviced on page 20 Recording Data Plate Information Once you have determined the unit is free from damage locate the data plate at the back of the unit The data plate indicates your unit s model number and
19. de years of trouble free operation Should you require assistance however SHEL LAB s customer service and support is available to assist you If your unit is still covered under warranty repair or replacement will be made at no cost to you according to the warranty given at the back of this manual If the warranty for your unit has expired you can still return the unit for repair If the unit proves to be beyond repair we will promptly inform you of its condition and if you want return the unit to you Obtaining Nameplate Information Before you contact customer service obtain the following information about your unit from the data plate at the back of the unit Use the spaces below to record the information Model Number e Serial Number 20 Returning Your Unit If you need to return your unit for any reason first contact your customer representative for return authorization number RA Be sure to print the RA clearly on the package in which you ship your unit No return is accepted without e prior authorization by SHEL LABS e a clearly visible RA on the package SHEL LAB Contact Information Please allow at least 24 hours from the time that you contact our service manager for service to be scheduled Contact Information Sheldon Manufacturing Inc P O Box 627 Cornelius Oregon 97113 Phone 503 640 3000 Toll free 1 800 322 4897 Fax 503 640 1366 Email tech Shellab com Internet ht
20. e After setting the chamber temperature wait at least 1 hour for the chamber temperature to stabilize to ambient conditions To achieve maximum temperature stability wait 24 hours before you begin using the unit Calibrating the Main Temperature Control Calibrating your unit ensures that the temperature inside the incubator matches the temperature reading of a certified reference thermometer We recommend that you calibrate your unit once it has been installed in its working environment and the chamber temperature has been stable at the set point for several hours You should calibrate your unit at or as close to the temperature set point as possible To maximize your results calibrate the unit each time you operate the unit at a new temperature Use only a Certified NIST temperature measuring device to calibrate your unit To verify that your unit needs calibration 1 Be sure the temperature within the chamber has stabilized at the set point for several hours 2 Insert a certified reference thermometer through the access porthole To attain the best calibration place the thermometer as close to the location of the samples Be sure the thermometer is not touching any shelving 3 Allow the reference thermometer to stabilize until it displays a constant value for one hour 11 4 Compare the temperatures displayed by the incubator and reference thermometer If they match you do not need to calibrate your unit
21. ection All major functions temperature RPM and time have audio and visual alarms that immediately alert you to deviations from set parameters Over temperature protection Provided by a safety thermostat that is independent of the main temperature controller Guards your samples from inadvertent overheating Key Features A brushless DC motor offers quiet and maintenance free orbital shaking motion A PID microprocessor controller provides precise uniformity The rotation platform is included with each unit and is self centering for easy installation Large LED displays are easy to read Digital keypad operation allows calibration of the main temperature controller to a reference thermometer A fluorescent light allows you to see all that s going on An interior electrical outlet and a one inch hermetically sealed double paned glass viewing window Unit exteriors are formed of cold rolled steel finished with corrosion resistant powder coat paint Chamber interiors and shelves are made of polished stainless steel which provides excellent durability and an easy to clean surface An interlock switch stops the shaking mechanism if the door is opened The SSI5R and SSI5R 2 SI6R SI6R 2 refrigerate using a 1 6 horsepower motorized compressor that does not use CFCs or HCFC s SHEL LAB SI6 SI6R Shaking Incubator Operational Manual Receiving Your Unit Unpacking and Inspecting Your Unit Before le
22. for that temperature If they do not match you need to calibrate your unit To calibrate your unit 1 Simultaneously press and hold the Set Temp Up and Down arrow keys After approximately 5 seconds the temperature reading will blink off and on Release the Up and Down arrow key 2 While the display is blinking press the Up or Down arrow keys to select the temperature that matches your reference thermometer When you hold an arrow key the display scrolls through the temperature settings The incubator accepts the new temperature reading after you release the arrow pads for 5 seconds At that time the display stops blinking 3 For best results re verify the calibration after the unit has remained on for 24 hours and its temperature has varied by no more than 1 C Setting the Shaker Speed Your unit is equipped with a shaker mechanism that provides maximum oxygenation of your samples You control the shaking mechanism using the shaker control which consists of a digital display that shows RPM rotations per minute in increments of 1 and UP DOWN arrow pads marked Set RPM and the RPM switch To turn the shaking mechanism on 1 Be sure the door is completely closed 2 Push the RPM switch to the On I position The shaker mechanism will increase the speed up to the current set point which is the speed at which the unit will rotate per minute Note that the shaker motor runs continuously as long the RPM s
23. it in conditions outside of these limits contact customer service Installing the Unit Installation of the unit can be performed by the end user Lifting and Handling The incubator is heavy and should be moved by a lifting device such as pallet jack If you must lift the device by hand always observe the following guidelines o Do not move the incubator while it is plugged into the power source o Remove all moving parts such as shelves and trays before you move the unit Make sure the door is securely shut o Use at least four people to lift the incubator o Lift the unit from its bottom surface only o Do not use doors handles or knobs to lift or stabilize the unit o Keep the unit from tipping Servicing Your Unit Only qualified personnel should service your unit Faulty service may be dangerous and will invalidate the units warranty Do not operate the unit if any parts are damaged or missing Maintenance Unplug the unit from its power source before attempting any maintenance SHEL LAB SI6 SI6R Shaking Incubator Operational Meanings of Symbols In this manual and on labels attached to the product graphic symbols have the following meanings Symbol Indcation About this Manual Throughout this manual the words WARNING and CAUTION have the following meanings AN i k C oe Pye You should consult this manual for a description or discussion of a control or item Temperature O
24. lastic brushes e Do not depend on the use of antibiotics to maintain completely sterile conditions as this is an inadequate technique for sterilization Instead use the aseptic techniques described in this section to maintain sterile conditions in the incubator You can use an autoclave to decontaminate stainless steel parts by following the manufacturer s instructions Otherwise wash all parts and surfaces with soap and water to remove any organic material 15 Disinfect the parts with a 70 alcohol solution Rinse with distilled water and wipe dry with a soft cloth A Typical Decontamination Procedure Following is decontamination procedure that will suit most situations WARNING Regardless of which decontamination procedure you follow always turn the unit off and disconnect the service cord from its power supply Before you reattach the unit to its power supply be sure all cleaners are evaporated and dry To decontaminate the unit 1 Unplug the unit from its power source 2 Remove all interior parts including shelves and shelf clips 3 Remove all disinfect all gaskets gaskets and hinges Clean and mounting grooves for the door 4 Clean and disinfect all rubber or plastic tubing as well as the fan and fan housing 5 Clean and disinfect all access ports shaft holes electrical pass throughs and any other passages into the chamber 6 Wash and disinfect all interior surfaces
25. n WARNING Always disconnect the unit from its power supply before attempting this procedure Serious injury can result if the drive plate operates accidentally To adjust the shaker movement 1 Unplug the unit from its power source Remove the sample tray 2 Rotate the counterweight platform until the stoke adjuster is in full view Remove the wing nut and adjust the arm to any of the available options 3 Re add the wing nut 4 Rotate the counterweight platform until the counterweights are in full view Remove the wingnuts and adjust the counterweights according to the diagrams shown below 5 Replace the counterweight wingnuts The following diagrams show the various positions of the shaker mechanism and _ counterweights The dimensions shown are the total stroke of the oscillator For example 2 designates a pattern that is inch from center The indicated parts on the mechanism are 1 Drive plate Counterweight Pivot nut Do not adjust Stroke adjuster Counterweight studs secure using wingnuts oa wo LV Stroke adjuster bolt secure using wingnut Oscillation Plate Overview 1 2 1 3 cm stroke setup light shaking 1 9 cm stroke setup moderate shaking 1 2 5 cm stroke setup vigorous shaking Oscillation Plate Overview 6 1 9 cm Stroke Setup Moderate Shaking middle counterweight stud 2 1 3 cm Stroke Setup Light Shaking left
26. nd help prevent contamination of your samples WARNING Do NOT Use Flammable Cleaning Detergents Do NOT store Flammable materials In On or Near this equipment Disinfecting Your Unit Although your operating conditions and related protocol should determine the actual decontamination procedures you use always keep the following guidelines in mind when decontaminating your unit e Use cleaning materials known to be compatible with your unit If any questions arise about compatibility issues contact Customer Service see page 21 e Clean and disinfect the incubator interior on a regular basis If the inside of your incubator smells strangely or contains rust mold or dirt you need to clean your incubator more frequently Dust the outside walls of the incubator at least every two months For incubators placed on the floor move the incubator every two months to clean and disinfect the floor below e Clean all gaskets and hinges every month Do not use chlorine based bleaches or cleaners with abrasives as they will corrode and pit the interior of you incubator and any other stainless steel surfaces Use only non abrasive cleaners Do not use spray cleaners that might leak through openings and cracks and get on electrical parts These cleaners may also contain solvents that will harm the coatings Do not use hard tools such as metal wire brushes or steel wool Use only soft tools such as p
27. ng 16 Solving Problems aiino a a e E A E E E 16 RETIN ST AUUIES E EE E AEA E A N T 16 Refrigeration SI6R models only essssessessessssssessesssesressessresressessresreeseestesreesreseeseessee 18 PO WEE EE E E E E teapaaeetennnemeamannes 18 Mechanical shest ie e a a aa e agii 19 Contamination ssrin a Bes daa A i lucas EA i sada Sua ES 19 Getting Your Unit Serviced 20 SHEL LAB SI6 SI6R Shaking Incubator Operational Manual Table of Contents ACMI PUSS TS CAO sade EE EE E EEE EEE ace nat E EA 20 Obtaining Nameplate Information ye cs snciga exc eat ge ndeiauns Baa dee vacnnees es genase Vonneeeenaeaeevndeandes 20 Returning Yo r Witt ceiiss cccaviesjecetuenpencevssedenssseetaacv es pedacasagena eacsod cada sbsnes T E E ii 20 SHEL LAB Contact ImiOriiat Onsale sci5 ss 8 cat cate es Sic nse den deg oh oat aitqueceevalcnaseeeeades 20 Replacement Parts and Accessories 21 R placement Parts at ee i ates a gence eas tease au gaia saaes cess E a aE oar eg soe 21 Specifications 22 These units are TUV CUE listed as orbital shaking incubators for professional industrial or educational use where the preparation or testing of materials is done at approximately atmospheric pressure and no flammable volatile or combustible materials are being heated These units have been tested to the following requirements CAN CSA C22 2 No 61010 1 2012 CAN CSA C22 2 No 61010 2 010 R 2009 UL 61010 1 2004 R 2005 07 R 2008 10 UL 61010A 2 010 2002 UL
28. ns of temperature RPM or time 6 RPM Switch Activates and deactivates the shaker platform 7 Light Switch Controls the fluorescent light inside the chamber 8 Timer Switch Activates and deactivates the timer 9 Power Switch e Controls all power to the unit The switch is lit by a green light when the power is on Series 10 Getting the Unit Ready for Use WARNING This equipment is NOT intended for the processing of Flammable materials Use the following guidelines to prepare the unit for regular use The guidelines illustrate how to use all the features of your incubator Your laboratory protocol will determine your actual use of these features 1 Turn the unit on See Turning the Unit On below on this page 2 Set the chamber to the desired temperature and wait for the chamber temperature to stabilize See Setting the Chamber Temperature on page 11 3 Calibrate the main temperature control At any time use the following features when appropriate e Turn the shaking mechanism on and adjust the speed of the shaking mechanism See on page 11 e Set the Over Temperature Protection OTP to guard your samples from inadvertent over heating See on page 12 e To account for the weight of different sample loads you will need to adjust the number of counterweights being used See on page 12 e To adjust the movement of the shaking mechanism from vigorous to
29. process e Turn the TIMER switch and the RPM switch to the OFF O position CAUTION Wait for the mechanism to come to a complete stop before entering the chamber To restart an interrupted timed shaking process e Turn the RPM and TIMER switch to the ON I position Setting the Safety Temperature Alarm You can prevent the chamber temperature from inadvertent over heating by using the unit s Over Temperature Protection OTP which consists of e a thermostat independent of the main temperature control e a knob marked Safety Temp to set the safety temperature threshold The numbered scale around the knob is for reference only and does not correspond to any temperature points e an alarm marked Temp that sounds if the temperature exceeds the user defined temperature threshold 12 To set the safety temperature thermostat 1 For best results calibrate your unit before you set the safety thermostat See Calibrating the Main Temperature Control on page 11 2 Be sure the temperature within the chamber has stabilized at the set point for several hours 3 Using a screw driver or a small coin turn the Safety Temp knob counterclockwise until the Temp alarm light turns on and off which designates that your OTP has been activated The light will cycle on and off as the element is trying to energize on and off 4 Turn the Safety Temp knob slightly clockwise until the Temp alarm light tu
30. r is faulty Or Electrical noise 1 Ifyou have just turned the unit on wait 24 hours for incubator to stabilize at a warmer temperature If this is not the problem the 2 If you have just opened the unit s door wait for the temperature to stabilize If this is not the problem 3 Stabilize ambient conditions If this is not the problem 4 Call customer service See page 21 Cannot adjust set points or calibration This is a controller failure 1 Turn entire unit off and then on to reset the unit This may temporarily solve the problem but controller may be faulty If this does not solve the problem 2 Call customer service See page 21 17 SHEL LAB SI6 SI6R Shaking Incubator Operational Manual What is the problem Possible Causes To solve the problem Refrigeration SSISR models only SI6R The unit will not cool The evaperator has too much ice built up on it a Or 5 The unit is not calibrated correctly z Or There is not enough space between the unit and adjacent walls or partitions Or gt The door seal does not work properly For diagnostics purposes turn the OTP fully clockwise See OTP section If this does not solve the problem Recalibrate the Main Temperature Controller See on page If this does not solve the problem a Be sure there is 5 cm 2 in of space between the rear and sides of the
31. r of the unit by turning its foot clockwise or counterclockwise respectively To level the incubator 1 Insert a leveling foot into each of the four holes at the bottom of the unit 2 Adjust the foot at each corner until the unit stands level and solid without rocking If you move the incubator to a different location be sure to re level the incubator at the new location Sterilizing Your Unit The interior of your incubator was cleaned at the factory but is not sterile For information on SHEL LAB SI6 SI6R Shaking Incubator Operational Manual sterilizing your unit see Disinfecting Your Unit on page 14 Installing Sample Tray Your unit comes with a sample tray as standard equipment To install the sample tray 1 Enclose all corners of the shaking mechanism within the lips of the sample tray This can be done easily by positioning the front two corners and then setting the rest of the tray down 2 Shake the tray by its handles to confirm that it is firmly in place Plugging the Unit into a Power Source We recommend that you plug your incubator into a circuit separate from other equipment This prevents damage or destruction of the incubator caused by overloading or failure of other equipment on the same circuit The electrical supply circuit to the incubator must conform to all national and local electrical codes The voltage supplied to your unit should not vary more than 10 WARNING
32. rage Call customer service See page 21 18 SHEL LAB SI6 SI6R Shaking Incubator Operational Manual What is the problem Possible Causes To solve the problem The wall fuse circuit break blows often Too many things may be plugged in 1 Check to see what other loads are on the same circuit as the unit We recommend that you plug your incubator into a circuit separate from other equipment The front panel displays fail to turn on but the rest of the unit receives power Controller failure 1 Call customer service See page 21 The Main Temperature Controller is locked up Controller failure 1 Turn entire unit off and then on to reset the unit This may correct the problem but the controller may still be faulty 2 Call customer service Mechanical The door is not sealing The door gasket does not function properly Or The door latch bolts are not tightened enough Or 2 The hinges are not adjusted properly es Or ra The door has been twisted A Or s The unit has been damaged and the body is not square 1 Check the gasket visually Make sure it s secure and smooth and free from rolls or tears which would interfere with the magnetic seal If this does not solve the problem 2 Tighten the door latch bolts with a screwdriver If this does not solve the problem 3 To tighten hinges use wrench to adjust and to check if the bolts are tight
33. rns off NOTE Temp Alarm will only sound off when temp overshoot 1 C from setpoint The OTP is now set at approximately 1 C above the main temperature set point If for any reason the chamber temperature rises to the safety thermostat setting the Temp alarm will go off and the heating element will not raise the chamber temperature any further Adding or Removing Counterweights To allow the smoothest operation of the shaker you should adjust the number of counterweights used based on the weight of the load To add or remove counterweights 1 Unplug the unit from its power source When the shaker mechanism comes to a complete halt remove the sample tray 2 Rotate the counterweight platform until the counterweight appears Remove the wing nuts and add or remove counterweights according to the total weight of your samples as shown below Number of Counterweights Total Sample Weight Up to 2 3 kg 5 Ibs Up to 4 5 kg 10 Ibs Up to 6 8 kg 15 Ibs Up to 9 kg 20 Ibs Up to 11 3 kg 25 Ibs 3 Replace the wingnuts and sample tray ou WP SHEL LAB SI6 SI6R Shaking Incubator Operational Manual Adjusting the Shaker Movement You can adjust the shaker movement to gentle moderate or vigorous shaking Which shaking movement you use depends on the oxygenation needs and cell strength of your samples When you change the stroke of the shaker mechanism you also need to adjust the counterbalance positio
34. t Mc cPP ROE Cone E ATE Installing Sample Li aya ks cevrpatadsa guests vsagselactoed senytaessevesies scheu vane giana terns tes SEES ain anes Plugging the Unit into a Power SOUrCe ceeccecesscecesececssneecesceeceseeecsceecseeeeceseeecsteeeenaes Operating the Unit 10 Control i E OAE YA TA E T A E E Sea I E 10 Getting the Unit Ready for UsS nsre erce eror irec eas oE E aiai 10 Turming the Unt Once n a E A E e E TR RRE 10 Setting the Chamber Temperature seessssesseeseseseeeeeseesresreeseessereresresesrrssresseseeesressessest 11 Calibrating the Main Temperature Control oo eee ceseeeeeeeseecsneceseeeeneeeseecaecsseeeees 11 Setting the Shaker Speed csis scecksdisases ccassavadeissavacsaxeaveasisegsaacasavadea e E raia I EE AE ES 11 Using th TIMET terien oen oe oe e E O ued agent tena eegeodackensaaienes 12 Setting the Safety Temperature Alarm essesessseessesssesseesseeesseesseesseesseeeesseessresseessee 12 Adding or Removing Counterweights sssssssessssssessseeessetssseessesseesseessseeesseessresseessee 12 Adjusting the Shaker Movement sssssesessseesseessesssessseeesseeesseesserssersseresseeesseesseesseessee 13 Interior Accessory ULC hae san eene a E iat a E aowes 14 Maintaining the Unit 15 Disinfecting Your Unitesesnsinsninnnnnnsip n a EN R i 15 A Typical Decontamination Procedure sseessessseesseeesseeesseessresseesseessseeesseessresseessee 15 Control M inten nt eseni e a a E RT 15 Troubleshooti
35. tor Operational Manual What is the problem Possible Causes To solve the problem Over Temperature Protection OTP is set too low as Or Heating element failure If this doesn t solve the problem 3 Be sure your reference thermometer is certified If this is not the problem 4 Turn the OTP fully clockwise If this doesn t solve the problem Call customer service See page 21 The Main Temperature Control displays LO Probe has shorted out Call customer service See page 21 The unit will not heat up to set point The amperage and voltage of the unit s power source do not match the unit s requirements Or Over Temperature Protection OTP is set too low 1 Make sure the power source matches the data plate i voltage hz etc If this does not solve the problem e 2 Turn the OTP clockwise until the heating light or safety light turns on The unit will not heat at all The OTP is not set high enough Or Temperature Controller failure Or Element failure 1 For diagnostics purposes turn the OTP fully clockwise See OTP section Call customer service See page 21 The indicated temperature inside the chamber is fluctuating more than 0 1 C The unit has not had time to stabilize to ambient conditions a Or 2 Temperature sensor not positioned properly Or The temperature senso
36. tp www Shellab com Shellab SHEL LAB SI6 SI6R Shaking Incubator Operational Manua Replacement Parts and Accessories Replacement Parts Part 115V 220V Part 115V 220V Adjustable feet 2700500 2700500 Motor Circulation 4880527 4880528 Alarm Display Vertical 1750681 1750681 Outlet Interior 4200518 6100531 Counterweight Single 5460662 5460662 Platform Sample Tray 9750758 9750758 Door Gasket 3450562 3450562 Power Cord 1800510 1800500 Drive Belt Oscillator 0500512 0500512 Seen cia 7010521 7010543 Element Coil 9570703 9570738 Flask Clamps 1 Liter 9530532 9530531 safely Thermostat 1730862 31 30802 Flask Clamps 125ml 9530530 9530530 shelf 9100931 9109934 Flask Clamps 250ml 9530531 9530531 Shelf Clips T250512 250512 Flask Clamps 500m 9530526 9530526 Swill Door 8303 8 8505 8 Fluorescent Lamp 4650528 4650528 Cone RPM Timer 7850553 7850553 Fuse 120V 3300513 NA Switch Power 4650554 4650554 puse cou NA 3300519 Temp Display Board 1750677 1750677 Fuse Holder 3300501 3300501 Timer Display Board 1750679 1750679 Knob Safety Thermostat 4450506 4450506 Transformer Speed Dees Sates Light Ballast 4660501 4660506 Control Light Cover 9510502 9510502 Light Cover Gasket 3450538 3450538 Light Holder 4660502 4660502 21 SHEL LAB SI6 SI6R Shaking Incubator Operational Manual Specifications SSI5 S16 SSI5R SI6R Temperature Unit Range 10 C above Ambient to 60 C 10 C above Ambient to 60 C Uniformity 0 8 C at 37
37. ver Temperature Safety Degrees Centigrade AC Power Manual Adjustable Components Oscillator Timer Light Indicates Unit should be recycled Not disposed of in land fill WARNING A potentially hazardous situation that if not avoided could result in serious injury or death CAUTION A potentially hazardous situation that if not avoided may result in minor or moderate injury or damage to the equipment SHEL LAB SI6 SI6R Shaking Incubator Operational Manual Features of Your Unit Product description Your shaking orbital incubator provides Controlled environment For continuous growth of biological organisms Vibration free operation A unique adjustable counterbalance system provides vibration free operation regardless of load Large chamber A large six cubic foot chamber facilitates throughput Shelves in the top provide space for static incubation during shaking sessions Refrigeration The SSI5R and SSI5R 2 SIR SI6R 2 are refrigerated which supports insect cell culture and entomology studies Load Flexibility Our unique counterbalance weighting system is adjustable to accommodate off center loads varying capacities and stroke lengths which in turn allows smoother running Oxygen transfer An adjustable orbit provides maximum oxygen transfer and offers three circular stroke sizes from vigorous to gentle to accommodate different types of cells Sample prot
38. witch is On I To adjust the shaker speed RPM 1 Press either the Up or Down arrow key once The display starts to blink from bright to dim and shows the RPM set point 2 Press the Up or Down arrow keys to select the desired RPM The incubator accepts the new set point after you release the arrow pads for 5 seconds At that time the display stops blinking and indicates the present RPM Even if you turn the RPM switch off O the controller remembers the last RPM value used You can adjust the movement of the shaking mechanism See page 13 SHEL LAB SI6 SI6R Shaking Incubator Operational Manual Using the Timer Using the incubator s timer you can run the shaker platform at a preset RPM for a preset time The timer can be set at intervals of one 1 minute up to a maximum of a 999 16 hours 39 minutes Upon completion of the timing cycle the TIMER alarm LIGHT will turn ON and an alarm will sound You can interrupt the timer if you need to access the shaking platform before the timer completes To start a timed shaking process 1 Turn the TIMER switch to the ON I position 2 Press the set timer up or down arrow key once The display starts to blink off and on and shows the current set time Press the up or down arrow to select the desired time Approximately five seconds after you release the Up or Down arrow keys the display stops flashing and the timing interval begins To interrupt a timed shaking