Home
GSM Gate Opener GSM Remote Switch
Contents
1. 12 6 5 Self check auto report inquiry status historical data IMEl code and firmware version 13 6 6 Data function 14 7 Important information 15 BA Fe lel cle 00 gt eee eS ae 15 9 Warranty 15 10 Authorized users list paper 16 This handbook has been designed as a guide to the installation and operation of RTU5025 Gate Opener Statements contained in the handbook are general guidelines only and in no way are designed to supersede the instructions contained with other products We recommend that the advice of a registered electrician be sought before any Installation work commences Caution Please read this user manual carefully before install operate the Gate Opener basic electronic acknowledges required cablematic 1 Product details The RTU5025 is an upgraded version of famous RTU5015 gate opener a very simple device which can be used for remote control swing or sliding gates and doors or switching devices with authorized access management Caller ID well used on door access gate control remote switching or car parking systems Actually the RTU5025 c
2. 6 3 2 Allow only the authorized numbers can call in to control Caller 1D for security default 6 3 3 How long time the relay keep close ON after phone call in unit second close time 000 999 Unit Second close time 000 relay close 0 5 second then open use the relay as Latch close time 999 relay will always keep close ON after call in untill the next call in Eg 1234GOT030 to set relay close 30 seconds ON and then open OFF after call in 6 3 4 Who will receive the confirmation SMS when the relay is ON OFF for relay ON for relay OFF ab the ID code of the 1 number a and the caller number b O means disable 1 means enable content confirmation SMS content Eg 1234GON11 Door Open The 1 number amp the caller number receive confirmation SMS when relay is ON door opened Eg 1234GOFF00 Door Close The 1 number amp the caller number will not receive confirmation SMS when relay is OFF door closed 6 3 5 No need confirmation SMS when the relay is ON OFF 6 3 6 Control the relay ON OFF by SMS command Return SMS Relay ON or the SMS confirmation content which you modified before Return SMS Relay OFF or the SMS confirmation content which you modified before The relay close timer according to the before setting 6 3 3 pwdGOTelose time www cablematic 6 4 Digital Input The RTU5025 equips 2 digital inputs DIN1 special for secure door and automatically armed when door
3. and then testing again 4 Please contact the distributor or manufacturer if the problem can t solved 9 Warranty 1 The RTU5O25 is warranted to be free of defects in material and workmanship for one year from the date of purchase 2 This warranty does not extend to any defect malfunction or failure caused by abuse or misuse by the Operating Instructions In no event shall the manufacturer be liable for any alarm system altered by purchasers The End Any questions please help to contact us feel free cablematic 10 Authorized users list print this page and fill in for record vw cablematic
4. Specifications GSM Frequency Quad band 850 900 1800 1900MHz 900 2100MHz default 3G Band 850 1900MHz optional Digita Input 2 NC NO dry contact Digital Output Siren Output DC Power supply Power consumption SIM Card Antenna Temperature range Humidity range Backup battery Exterior dimension Net Weight 1 Relay 3A 240VAC 12VDC 1A 9 24VDC 2A 12V input Max 50mA Average 25mA Supporting 3V SIM Card 50 Q SMA Antenna interface 20 60 C Relative humidity 90 3 7V 900mAH W130mm D74mm H27mm 260 g 1 3 Dimensions wwrw cablematic 1 4 Standard Packing List SA SS NON Gate Opener 1 Antenna 1 AC DC Power adaptor 1 User Manual amp PC Software CD x1 Packing size 19 14 6 cm Gross Weight 0 75kg Optional Accessories Ry Se O ARS Door contact sensor Motion detector Temperature sensor Infrared Beam Fence Vibration sensor Siren and others 1 5 Applications VV VV V WV Order Table RTU5025 GSM 850 900 1800 1 900MHz RTU5025W 2G GSM900 1 800MHz 3G WCDMA 900 2100MHz UMTS RTU5025C 2G GSM850 900 1800 1900MHz 3G 850 1900MHz UMTS Remote open close swing sliding gates doors shutters garage doors locks with a free call Intrusion security alarm remote ON OFF motors lights pumps generators valves and machines Residential Door gate garage access control electronic fan microwave air conditioner control Industry Remote switch equipment for example street
5. closed SMS alert send to the 1 6 positon number immediately when door opened illegally DIN2 for motion smoke or other sensors to protect your assets SMS alert send to the 1 6 positon number when there have any alarm occurance On alarming situation after alert SMS send out RTU5025 will call the 1 number and next number if there have no answering Disarm 6 4 1 Arm 6 4 2 Define the DIN1 DIN2 type Eg 1234DIN2NO define the DIN2 as NO Normally Open type 6 4 3 Modify the Alert SMS content when inputs alarm Max 32 characters E g 1234M2 Window open alarm Modify the DIN2 alert SMS content to Window open alarm DIN1 default alert SMS content Door opened illegally DIN2 default alert SMS content DIN2 Alarm 6 4 4 Inquiry the NC NO type and Alert SMS content of DIN1 2 6 4 5 Digital alarm conditions The DIN1 DIN2 will trigger an alarm only under the below two coditions e RIU5025 under the Armed Mode e 10mins after the last call in from the authorized numbers 10mins default users can modify the time period by SMS command xxx 000 999 unit minute xxx 000 RTU5025 will always disarm untill arm by SMS command www cablematic 6 5 Others 6 5 1 Power failure alarm unit minute xxx 000 999 xxx 000 power failure alarm SMS to the 1 number once the AC DC power supply lost xxx 999 default no power failure alarm SMS to be send 6 5 2 Self check auto report SMS to t
6. lights solar power motor inverter PLC pumps fans etc Agriculture Remote control pumps etc Business Remote control electronic boxes bright billboards LED signs etc 2 Safety Directions Safe Startup danger Interference performance Reasonable Use Avoid Use at Gas Station Do not use Gate Opener at a gas station Power off Gate Opener when it near fuels or chemicals Do not use Gate Opener when using GSM equipment is prohibited or might bring disturbance or All wireless equipment might interfere network signals of Gate Opener and influence its Power it off near Blasting Places Please follow relevant restrictive regulations Avoid using the device in blasting places Please install the product at suitable places as described in the product documentation Avoid signal shielded by covering the mainframe Use Qualified Maintenance Service Maintenance can be carried out only by qualified maintainer cablematic 3 Diagram USB ATN UCI A D GE Dhan Power Alarm Relay all GSM Gate Opener GPRS 3G Gate Opener Remote Access Control Unit RTUSO0O25 I Power Digital Input Relay Output Siren Oocs 5v 5 on S con Ne e el 8 9 o INDICATORS Power ON AC DC power supply is ON Alarm Flash quickly Alarm occurance Relay ON Relay closed ON Door Status DIN GND Digital Input Relay Output Flash per 1 second quickly registering to cellular network Flash
7. 1 Only the authorized number can ca Y Default Only the authorized number can call to control Export profile 30 Default 0 means relay ON 0 5 seconds then OFF after call in PAR 3 Admin Number Caller Number v Default3 Admin Number Caller Number 3 Admin Number Caller Number M Default3 4dmin Number Caller Number Relay on 1234561 Up to 40 characters Relay OFF Up to 40 characters 2 Default 399 means no alarm Setting as OOO alarm SMS once power failure 1 Default 0 means no report 1 Default 9999 disable Setting as 0 means always on line 65535 Default 65535 Call mobile operator to ask the APN name if you need data function Call mobile operator to ask the APN name if you need data function Call mobile operator to ask the APN name if you need data function com Port Read Settings Read the basic parameter settings from RTU5025 to PC software Save Settings Save the basic parameter settings to the RTU5025 Import profile Import xls profile this can use for a number of RTU5025 with similar settings Export profile Export the parameter settings as xls format to the PC under the configuration folder SALS cablematic KARASA d O NS GSM GPRS 3G Gate Opener GSM GPRS 3G Remote Switch 2 Edit Authorized Number List COM Port COM3 v Close Serial Authorized number Start Time Always WI Delete Y Password 1234 Log in Basic Settings 008613410846609 8615012741010 m E a L Number List m a E L Import L
8. 911 this step is MUST 4 Connect the RTU5025 to computer by USB cable 5 On compurter s desktop right click My Computer gt gt gt Property gt gt gt Hardware gt gt Device Manager 6 Find Ports COM 8 LPT check the port number of Silicon Labs CP210x USBto UART Bridge for example COM3 Search on Google and download the CP210x USB driver for your OS to RTU5025 for adjust the time 7 Run this configurate software select the COM Port number for example COMS click Open the downside COM Port status indicates to Green connection successful 8 Click Log in default password is 1234 Fill the new password if you had changed before 9 Click Read Settings Configurate the parameters as per you need 10 Click Save Settings 11 After finished the configuration disconnect the USB cable restart the unit for enter to working status 1 Basic settings E Remote Gate Opener Configurator 1 5 e x COM Port Mu Close Password 1234 Log in INS OO Sepings 1234 Default Password 1234 Read Settings 13632549841 Up to 21 digits Support country code A 1 NO Default NO Must setting to NC if connect the door locks Number ONC Default 1 NO List Save Settings Unauthorized door opened Up to 40 characters DIN2 Alarm Up to 40 characters Historical A pila 20 Default 10 Uint Minute Setting to O means Auto Arm after 10s when door closed Data 1 Arm iv efault Disarm System will alarm only on Arm status
9. BUY ON www cablematic co Table of contents 1 Product details 3 LU POIS rn ANNA AAA AAA NAAA NARRAN 3 1 2 Specifications gt 3 A nn ee a a a 3 1 4 Standard Packing List and Model Tabel 4 1 5 ApplicationS 4 2 Safety Directions 4 3 Diagram 5 4 Typical Wiring Connection T 5 Setting by PC software 7 5 1 Basic SettingSs 7 5 2 Authorized number list managerment 8 onda ee Ee O ADA nd la a RN 8 6 Setting Operating by SMS commands 9 6 1 Change password 10 6 2 Authorized number managerment 10 Ga MAA conoi parine Ta Grattan A NA A AAA A 11 6 4 Digital Input parameterS
10. S E B Historical 18565867767 2015 02 09 23 00 2015 03 24 10 04 E E Data 13822927369 2015 03 24 10 00 2015 03 24 11 04 E Export LS 15361421690 2015 01 21 09 00 2015 03 24 10 04 a E 13510150873 Y L Help Export CSW E a E All Always 5 5 E E amp E Delete all i E a B Read Read the authorized number list from RTU5025 to the PC software Save Save the authorized number list to RTU5025 Import xls Import authorized number list xls format profile from PC folder to the software Export xls Export the authorized number list xls format to the PC under the configuration folder Export csv Export the authorized number list csv format to the PC under the configuration folder All Always Select all the numbers as Always can call in to the RTU5025 for access control Delete all Delete all the numbers on the list after click this button then click Save button all the numbers on the RTU5025 will be deleted Caution to use 3 Historical Data Remote Gate Opener Configurator 1 5 COM Patt COM3 v Close Password 1234 Log in Settings Content 2015 03 26 15 41 56 Telephone Relay ON 13410846609 Relay ON notification Number 2015 03 26 17 01 11 SMS Relay ON 8613410846609 DoorOpen me Export CSV 2015 03 26 17 01 18 SMS Relay ON 8613410846609 DoorOpen 2015 03 26 17 02 06 SMS Relay ON 8613410846609 DoorOpen Historical Export lt LS 2015 03 26 17 17 27 SMS Add num
11. an be used in places which require to turn ON OFF your system machines equipments remotely with a FREE phone call from your mobile or fixed line telephone PC software for programming via USB remote server system over TCP IP supported users can easily download the access historical data anywhere anytime 1 1 Features Advantages gt GSMor 3G band distribute worldwide applications gt Up to 999 authorized phone numbers can be configured at the specified time for access control gt No call charges Reject calls from authorized number then carries out the turn ON OFF action on the first ring gt Secure Using Caller ID for verification unknown phone calls are ignored gt SMS confirmation of relay actions door open to the owner or authorized caller number gt No need remote control or keys for different users gt Up to 1 000 events log download the operation historical dat by USB or over GPRS gt Multiple applications gates bollards barriers garage doors shutters and access doors or machines Digital Inputs gt One Digital input for motion sensor or other sensors to protect your door and windows SMS alert to owner immediately when triggered gt One Digital input special for secure door and automatically armed when door closed SMS alert to owner immediately when door opened illegally Setting gt SMS command or PC Software programming gt Operate from anywhere anytime no distance limitation 1 2
12. ber 8613410846609 13410846609 piri 2015 03 26 17 19 53 SMS Add number 8613410846609 13110150873 2015 03 26 17 23 13 SMS Relay ON 8613410846609 DoorOpen 2015 03 26 17 23 56 SMS Relay OFF 8613410846609 Relay OFF Again Help 2015 03 26 17 42 30 SMS Arm 8615012741010 2015 03 26 17 50 01 Telephone Relay ON 15012741010 Relay ON 2015 03 26 17 51 43 Telephone Relay ON 13410846609 Relay ON Delete all 2015 03 26 17 53 40 SMS Add number 8615012741010 15012741010 2015 03 26 17 53 58 Telephone Relay ON 15012741010 Relay ON 2015 03 26 17 55 10 SMS Relay ON 8613410846609 Relay ON Read data Read all historical data from RTU5025 to PC software Filter Filter data from the Start End time Export xls Export the historical data xls format to the PC under the configuration folder Export csv Export the historical data csv format to the PC under the configuration folder Deleta all Click this button will deleta earse all of the historical data on the RTU5025 Caution to use cablematic Page 8 of 16 Ver 1 5 File No RTU5025103 6 Setting by SMS commands not recommend for remote setting only 1 The default Password is 1234 2 You can program the RTU50O25 with SMS commands using your phone It is safe to do so because in addition to the fact that other people may not know the number of the SIM inserted in it we also use a Password that makes it impossible for others who doesn t know it to access the system by cha
13. he 1 number unit hour xxx 000 999 xxx 000 default no self check auto report Auto report SMS including l DIN1 2 status Relay status GSM signal value full is 31 cellular signal weak if lower than 14 AC DC power supply status Inquiry the self check and auto report time 6 5 3 Inquiry current status 6 5 4 Inquiry the historical data through SMS Eg 1234L 150101 150105 to inquiry the historical data from Janurary 1 to Janurary 5 2015 6 5 5 Inquiry the GSM modules IMEI code and firmware version 6 5 6 RESET the password Press and hold the RESET button closed to the SIM card holder then power ON after 6 seconds later the RTU5025 will restart then release the RESET button This operation will reset the password to default 1234 only other parameters reset must be reset by PC software 6 5 7 Device ID RTU5025 will create an ID according to the SIM Card number ine last of 8 digits 6 6 Data function GPRS UMTS HSDPA Parameters RTU5025 can send historical data to remote Central Management System CMS server software over mobile network TCP IP users have to build their own remote server system according to the RTU5025 data protocol The CMS software can be server based 500 800usd or web based 12 000usd due to the high cost this function for customer who purchased more than 100pcs RTU5025 only for small project we suggest client using PC software to configurate or read historical da
14. nce and all the action will be recorded 3 The relay output will change the close or open status by every call in please note it Means the first time call it it will close the relay to switch on the lock if the second call in is in the setting time then the unit will ignore the setting time and open the relay to switch off the lock 4 Remember that commands must be CAPITAL LETTERS It is AA not aa EE not Ee etc Don t add spaces or any other character on the SMS commands 5 The pwd in the command means the password like 1234 or 5678 if you changed 6 Ifthe RTU5025 used for gate access only all you need to do is to change the default password and add the authorized numbers 7 If you cannot call to control the RTU5025 or cannot send or receive any SMS message from it please try to add in front of the country code or the phone numbers For example In China the country code is 0086The user cell phone number is 13570810254 and has been assigned as the SMS Alert number the simcard number in the panel is 13512345678 Problem 1 Alarm but the user hasn t received the SMS Alert Solution Please plus the country code while you setup the 13570810254 as SMS Alert number means setup 008613570810254 instead of the 13570810254 Problem 2 The user number can receive the SMS Alert message from alarm panel but the alarm panel can not receive the commands from the user number Solution Please add country code to the simcard numbe
15. per 2 seonds Normal status OFF can t connect to SIM card or unregistered to the cellular network Connection Terminals Power supply input Positive wire Red Power supply input Negative wire Black DIN1 Connect to the door lock s contact points if have or door contact sensor voltage free dry contact ports DIN2 Connect to sensor detectors voltage free dry contact ports Normally Open port Common port Normally Close port 12V DC output connect to siren s Positive wire GND connect to siren s Negative wire Connect to PC for configuration and reading the historical data Connect to GSM 3G antenna cablematic MA qa 4 Y S A ES a 2 sal gt a dato UNU E DE TUS Ww F Ww EE GW M 4 Typical wiring connection RTU5SO25 RTU5025 for Gate opener Connect the door sensor to DIN1 for door status detection and siren for alarm sound the lock switched ON OFF by phone call power gain from the same AC DC adaptor Remote Access Control Unit RTU5SO25 550 51 o amp Level sensor RTU5025 for remote switching pump Connect the water level sensor to DIN2 for level detection and siren for alarm sound the pump switched ON OFF by phone call Pump s power gain from the grid electrocity cablematic 5 Setting by PC software instructions recommend 1 Open the unit s back side cover and insert the SIM card 2 Connect the unit s power supply 3 Send SMS command for example 1234TEL001
16. r in the alarm panel Means send sms commands to 008613512345678 instead of Solution 3 Use mobile phone A to call mobile phone B the number displayed on B is which you should set as the dial number Use mobile phone A send SMS to mobile phone B the number displayed on B is which you should set as the SMS alert number sometimes you may need to use the 00 to replace the or use the to replace the 00 on front of the country code 8 Export the Authorized number list to xls csv file and keep it for reference in further 9 Fo security purpose the RTU5025 will note return any SMS if command error so please make sure and check the SMS Commands or add the country code before the telephone number or check the input is in ENGLISH INPUT METHOD and CAPS LOCK 10 The SMS commands that you will certainly use in the RTU5O25 are the following cablematic 6 0 Start this step is MUST Send to the RTU5025 for adjust the time E g 1234TEL00861351015 if the SIM card number inside the RTU5O25 is 00861351015 RTU5025 Reply Set Suces 6 1 Change Password RTU5025 return Password changed to new password please remember it carefully if sucessfully E g 1234P6666 for change the new password to 6666 6 2 Authorized number managerment 6 2 0 Add authorized number A command code serial number the authorized number s position from 001 999 start time yy year mm month dd day hh hour mm minute the start
17. ta via USB cable or SMS 6 6 1 Enable data function Disable data function 6 6 2 APN call your mobile operator to ask the Access Point Name private APN supported Eg 1234Geverywhere eesecure securejt the example APN name everywhere user eescure password secure supported by Orange UK 6 6 3 CMS Server IP address or DNS DDNS and server port Eg 12341P175 164 49 20 4006 When data connection failure or parameters setting wrong RTU5025 send SMS to the 1 number A SS eS eS a GPRS connect failure 5 6 5 Data upload to CMS interval time xxxx 0000 9999 unit minute xxxx 0000 data function always on RTU5025 can receive and send data over GRPS UMTS HSDPA xxxx 9999 default disable data upload function www cablematic 7 Important information 1 Please read the User Manual carefully before you install and control the RTU5025 2 Install the RTU5O25 in a hidden place 3 Avoid getting water into the RTU5025 4 Have a secure connection to the main power supply 8 Maintenance 1 In case of failure please contact the distributor or manufacturer 2 Ifthe RTU5O25 works but fail to send SMS texts switch the power off and on again after one minute Test it after few minutes later or ensure and check the settings are correct and the cellular signal strong enough 3 Ifthe RTU5025 works well with sensors but cannot send SMS texts please change a SIM Card from another Mobile Operator s
18. time of this number can call in to control end time yy year mm month dd day hh hour mm minute the end time of this number can call in to control Without start time and end time means Always can call in to control E g 1234A003 123456 to set the phone no 123456 at the 3 position and always can call in to control E g 1234A01 6 1 23456 1 502050800 1502051000 to set the phone number 123456 at the 16 position this number can call in to control during Feb 5 8 00a m 1502050800 to Feb 5 10 00a m 1502051000 Note 1 The authorized number means the one who can dial the RTU5025 to control the relay 2 The Serial Number is the position to store the authorized users from 001 999 3 The 1 6 position number should be Mobile number because of the alarm message will send to these 6 numbers and the power failure alarm SMS send to the 1 postion number only 6 2 1 Inquiry the Authorized number s position serial E g 1234A002 to check the number on the 2 position serial number2 6 2 2 Inquiry batch users number E g 1234AL002 0504 to inquiry the authorized numbers from the 2 to the 50 RTU5025 return serval SMS with the numbers list 10 numbers on each SMS 6 2 3 Delete the Authorized Number or you can overwrite this postion with another number E g 1234A002 to delete the 2 authorized number wwrw cablematic 6 3 Relay Control setting 6 3 1 Allow all numbers can call in to control
Download Pdf Manuals
Related Search
Related Contents
2 - imaginArt Samsung SGH-C180 service manual Kenmore 10,000 BTU Room Air Conditioner Owner's Manual the CFSE Manual - Kenton Electronics Bekijken/Opslaan - arexx engineering Milliken Millwork 36MP225LH Instructions / Assembly Ultrabond Eco 350 Ultrabond Eco 350 19 anno - piazza affari Copyright © All rights reserved.