Home
USER MANUAL
Contents
1. www prolight co uk SYNCRO DRAPE prol ight co SYSTEM uk LEDJ Pro Syncro Drape System Order code STAR30 USER MANUAL STAR30 indd 1 15 03 2013 10 18 A E LEDJ Pro Syncro Drape System Safety WARNING FOR YOUR OWN SAFETY PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START UP CAUTION Keep this eguipment away from rain moisture and liguids SAFETY INSTRUCTIONS Every person involved with the installation operation 4 maintenance of this equipment should Be competent Follow the instructions of this manual CAUTION TAKE CARE USING THIS EQUIPMENT HIGH VOLTAGE RISK OF ELECTRIC SHOCK Before your initial start up please make sure that there is no damage caused during transportation Should there be any consult your dealer and do not use the equipment To maintain the equipment in good working condition and to ensure safe operation it is necessary for the user to follow the safety instructions and warning notes written in this manual Please note that damages caused by user modifications and damage to the wiring loom inside the cloth are not subject to warranty STAR30 indd 2 15 03 2013 10 18 PENERE o LEDJ Pro Syncro Drape System IMPORTANT The manufacturer will not accept liability for any resulting damages caused by the non observance of this manual or any unauthorised modification to the equipment
2. Never let the power cable come into contact with other cables Handle the power cable and all mains voltage connections with particular caution Never remove warning or informative labels from the equipment Do not open the equipment and do not modify the equipment Do not connect this equipment to a dimmer pack Do not switch the equipment on and off in short intervals as this will reduce the system s life Only use the equipment indoors Do not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the power cable Make sure that the available voltage is between 220v 240v Make sure that the power cable is never crimped or damaged Check the equipment and the power cable periodically If the equipment is dropped or damaged disconnect the mains power supply imme diately Have a qualified engineer inspect the equipment before operating again If the equipment has been exposed to drastic temperature fluctuation e g after transportation do not switch it on immediately The arising condensation might dam age the equipment Leave the equipment switched off until it has reached room temperature lf your product fails to function correctly discontinue use immediately Pack the unit securely preferably in the original packing material and return it to your Prolight dealer for
3. 106 Choose a start address so that the channels used do not overlap E g the next unit in the chain starts at 107 DMX 512 e DMX Digital Multiplex is a universal protocol used as a form of communication between intelligent fixtures and controllers A DMX controller sends DMX data instructions form the controller to the fixture DMX data is sent as serial data that travels from fixture to fixture via the DATA IN and DATA OUT XLR terminals located on all DMX fixtures most controllers only have a data out terminal DMX Linking e DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assigned to a DMX address of 1 may be placed anywhere in a DMX line at the beginning at the end or anywhere in the middle When a fixture is assigned a DMX address of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter where it is located in the DMX chain DATA Cable DMX cable reguirements for DMX operation e The LEDJ Syncro Drape System can be controlled via DMX 512 protocol The DMX address is set on the back of the unit You
4. service Only use fuses of same type and rating Repairs servicing and power connection must only be carried out by a qualified technician THIS UNIT CONTAINS NO USER SERVICEABLE PARTS WARRANTY One year from date of purchase OPERATING DETERMINATIONS If this equipment is operated in any other way than those described in this manual the product may suffer damage and the warranty becomes void Incorrect operation may lead to danger e g short circuit burns electric shocks lamp failure etc Do not endanger your own safety and the safety of others Incorrect installation or use can cause serious damage to people and property STAR30 indd 3 Safety 15 03 2013 10 18 A DS LEDJ Pro Syncro Drape System Technical Specifications You should find inside the carton the following items 1 Syncro Drape System 2 Instruction manual 3 Controller Technical Specifications Controller 3 x 2M Curtain DMX channels 8 176 x 5mm tri colour LEDs DMX sound active auto modes Heavy duty fire retardant wool serge 30 built in programmes Metal eyelets on all 4 sides 4 push button menu with LCD display Dimensions 3 x 2M 3000 x 2000mm 3 pin XLR in out sockets Weight 4 4Kgs 5 pin XLR out sockets IEC power in socket 2 2 X 1M Table Cloth Power on off switch 78 x 5mm tri colour LEDs Power consumption 150W Max Heavy duty fire retardant wool serge Power supply 100 240V 60 50Hz Dimensions 2 2 x 1M 2200
5. ectors e Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 Pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The Chart below details the correct cable conversion o Pin XLR socket i screen A 3 Pin XLR socket Pin 1 A Pin 2 Signal n Pin 1 GND AA Pin 3 Signal ra Pin 2 Signa R Pin 4 N Pin 3 Signal Pin 5 N C i 5 Pin XLR socket 3 Pin XLR socket f Pin 1 GND screen Pin 1 GND een Pin 2 Signal Pin 2 Signal z Pin 3 Signal Pin 3 Signal Pin 4 Nie Pin 5 N C STAR30 indd 8 15 03 2013 10 18
6. ow DMX512 on the LCD display Now press the ENTER button and use the UP or DOWN buttons to select YES or NO Now press the ENTER button and use the UP or DOWN buttons to set the DMX address from 001 512 Once you have made your choice press the ENTER button to conform your setting Built in Programmes To access the Pro Syncro Drape System s built in programmes press the MODE button to show PROGRAM on the LCD display Now press the ENTER button and use the UP or DOWN buttons to scroll through the built in programmes Now you can choose any of the particular programmes you wish to have turned on or off in any of the above modes To do this scroll to the desired programme and press the ENTER button and use the UP or DOWN buttons to select YES or NO on the selected programme For example if you set programmes 1 20 to OFF then only the programmes 21 30 will play in your light show Once you have made your choice press the ENTER button to conform your setting Version Mode To access the Pro Syncro Drape System Version mode press the MODE button to show VERSION on the LCD display Now press the ENTER button and use the UP or DOWN buttons to show the current version 100902 LED252 STAR30 indd 5 15 03 2013 10 18 SCL i j i LEDJ Pro Syncro Drape System Operations 8 channel DMX cha
7. r unit and your DMX controller reguire a standard 3 pin or 5 pin XLR connector for data input output figure 1 Figure 1 Further DMX cables can be purchased from all good sound and lighting suppliers or Prolight dealers Please guote CABL10 2M CABL11 SM CABL12 10M Also remember that DMX cable must be daisy chained and cannot be split STAR30 indd 7 15 03 2013 10 18 A LEDJ Pro Syncro Drape System DMX Set Up Notice e Be sure to follow figures 2 4 3 when making your own cables Do not connect the cable s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR s outer casing Grounding the shield could cause a short circuit and erratic behaviour common DMX 512 out DMX 512 in 3 pin XLR 3 pin XLR aa XLR MALE SOCKET XLR FEMALE SOCKET XLR Pin Configuration 2 cold 1 ground 1 ground 2 cold Pin 1 Ground Pin 2 Negative FIGURE 3 FIGURE 2 Special Note Line termination e When longer runs of cable are used you may need to use a terminator on the last unit to avoid erratic behaviour Termination reduces signal transmission problems o and interferance it is always advisable to connect a Y o DMX terminal resistance 120 Ohm 1 4 W between pin 2 DMX and pin 3 DMX of the last fixture Using a cable terminator part number CABL90 will decrease the possibilities of erratic behaviour 5 Pin XLR DMX Conn
8. rt Channel DMX Address Function CH 1 0 255 Master dimmer 0 100 No function CH 2 6 255 Strobe slow to fast 0 255 Red 0 100 dimming 0 255 Green 0 100 dimming CH 3 CH 4 CH 5 P cn 0 255 Blue 0 100 dimming 0 16 17 33 34 50 Programme 1 Programme 2 Programme 3 51 67 Programme 4 68 84 Programme 5 85 101 Programme 6 CH6 102 118 Programme 7 Programme 8 136 152 Programme 9 Programme 10 Programme 11 Programme 12 Programme 22 Programme 23 CH 7 136 152 Programme 24 153 169 170 186 Programme 26 187 203 Programme 27 204 220 Programme 28 221 237 Programme 29 238 255 Programme 30 Programme 25 STAR30 indd 6 15 03 2013 10 18 A DS LEDJ Pro Syncro Drape System DMX Set Up DMX Control Mode Operating in a DMX control mode environment gives the user the greatest flexibility when it comes to customising or creating a show In this mode you will be able to control each individual trait of the fixture and each fixture independently Setting the DMX address The DMX mode enables the use of a universal DMX controller Each fixture requires a start address from 1 511 A fixture requiring one or more channels for control begins to read the data on the channel indicated by the start address For example a fixture that occupies or uses 7 channels of DMX and was addressed to start on DMX channel 100 would read data from channels 100 101 102 103 104 105 and
9. x 1000mm Dimensions 290 x 185 x 56mm Weight 1 9Kgs Weight 1 8Kgs Overview ed SYNCRO DRAPE SYSTEM wwwprolight co uk UUO Vs DEDE ENTER Pon 100 250V F10A 250V OC F6A 250V OC o o o FUSE FUSE DMX DMX ss 3 x 2M Cloth 2 x 1M Cloth POWER INPUT STAR30 indd 4 15 03 2013 10 18 A LEDJ Pro Syncro Drape System Operations Operations Sound Active mode To set the Pro Syncro Drape System into Sound Active mode press the MODE button to show SOUND on the LCD display Now press the ENTER button and use the UP or DOWN buttons to select YES or NO Once you have made your choice press the ENTER button to conform your setting Auto Run Mode To set the Pro Syncro Drape System into Auto run mode press the MODE button to show AUTOMATIC on the LCD display Now press the ENTER button and use the UP or DOWN buttons to select YES or NO Once you have made your choice press the ENTER button to conform your setting To change the speed of the auto run mode press the MODE button to show SPEED on the LCD display Now press the ENTER button and use the UP or DOWN buttons to set the speed from 1 9 1 Slow 9 Fast Once you have made your choice press the ENTER button to conform your setting DMX Mode To set the Pro Syncro Drape System into DMX mode press the MODE button to sh
Download Pdf Manuals
Related Search
Related Contents
DeWalt DW292 Impact Driver User Manual User Manual - Pressure Care Le point sur… Braille Wave Dataflex ViewMate Combo Conference Trolley 722 STM8SVLDISCOVERY STM8S value line discovery Copyright © All rights reserved.
Failed to retrieve file