1. Industrial 10 100BaseTX to 100BaseFX Media Converter o 100T To 100FA tha diz Cor ve raf Media onverl Rev 1 00 08 August 2006 FCC VVarning This Equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna m Increase the separation between the equipment and receiver HE Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Content OO GO e paa e E 1 Fe GS e e e E da gedeeedenuehereacsae 1 Package COntents ccccccsecccsseeteeeeteneeseeeeteeetanes 2 Hardware Description na nana nana nane anen eee neve arenen 3 Physical Dimension aje pe
2. Wavelength 1310nm Fiber Distance Multi Mode Fiber 2Km Available on Multi mode model Single Mode Fiber 30Km Available on Single mode model Link Lost Forvvard LED Povver consumption Reserve polarity protection TX S Fiber lf TX port link down the media converter will force Fiber port to link down Fiber TX If Fiber port link down the media converter will force TX port to link down u DIP Switch 1 ON Enables Port Alarm OFF Disables Port Alarm u DIP Switch 2 ON Enables LLF Link Lose Forwarding OFF Disables LLF Link Lose Forwarding DIP Switch 3 ON 100Base FX Half mode OFF 100Base FX Full mode u DIP Switch 4 ON 100Base TX Full duplex mode OFF Auto Negotiation m Power Green Povveri Green Power2 Green Fault Orange m Fiber Link Activity Green Half Full Duplex Orange m TX 10 100 Green Link Green Half Full Duplex Orange Input Voltage 12 to 48VDC Redundant inputs 4 6 Watts 20 Overload current Present protection Operation 0 to 60 C 32 to 140 F Temperature Storage 40 to 85 C Temperature Ambient Relative 5 to 90 non condensing Humidity 54 mm W x 135 mm H x 105mm D FCC Class A GE EN6100 4 2 CE EN6100 4 3 CE EN 6100 4 4 CE EN6100 4 5 CE EN6100 4 6 Safety UL cUL CE EN60950 IEC 60068 2 32 21
3. Please refer to the LED Indicators section for LED light meaning 8 When all connections are all set and LED lights all show in normal the installation is complete Troubles shooting m Verify that you are using the right power cord adapter DC 12 48V Please don t use the power adapter with DC output bigger than 48V or it will burn this converter down m Check the configuration DIP switch It must be setting in the same operation mode with the link partner m Select the proper UTP Fiber cable to construct your network The single mode converter must use single mode fiber cable Please check that you are using the right cable Don t both use multi mode and single mode lf the Industrial media converter LED indicators are normal and the connected cables are correct and the packets still cannot transmit Please check your system s Ethernet devices configuration or status Technical Specification Industrial 10 100BaseIX to 100BaseFX Media Converter technical specification are following Standard Connector Switch architecture Fiber parameters IEEE802 3 10BASE T IEEE802 3u 100BASE TX 100BASE FX IEEE802 3x Flow Control and Back pressure Fiber SC Multi Mode model SC Single mode model 30Km RJ 45 Socket CAT 3 5 10 100Mbps Twisted Pair cable Auto MDI MDI X and Auto Negotiation Function Support Store and Forward Fiber Core Multi Mode 62 5 125um 50 125um Single Mode 8 125um 10 125um
4. L a 1010m UTP Port Front Panel of the Industrial 10 100BaseTX to 100BaseFX Media Converter 3 Bottom View The bottom view of the Industrial 10 100BaseTX to 100BaseFX Media Converter consists one terminal block connector within two DC power inputs and one DC IN power jack Oooo oe oo OTO QO OO QO OO DO OO CO QO QO OO SQ OO KI AK UG OU OD OU Dc IN PWR2 1A 24V PWR4 PJ Power Input DC 24V 12V 48V H ye yee Lt Yi Wie Fault Bottom Panel of Industrial 10 100BaseTX to 100BaseFX Media Converter Ports E RJ 45 Port The UTP ports will auto sense for 10Base T or 100Base TX connections Auto MDI MDIX means that you can connect to another Switch or workstation without changing straight through or crossover cabling See the Figure C and C 1 for straight through and crossover cabling schematic RJ 45 Pin Assignments Pinner Assignment NOTE and signs represent the polarity of the wires that make up each wire pair All UTP ports on this Industrial media converter support automatic MDI MDI X operation you can use straight through cables See Figure for all network connections to PCs or servers or to other switches or hubs In straight through cable pins 1 2 3 and 6 at one end of the cable are connected straight through to pins 1 2 3 and 6 at the other end of the cable The table below shows the 10BASE T 100BASE TX MDI and MDI X port pin outs Pin MDI X
5. LED on the Industrial media converter will light up Please refer to the LED Indicators section for meaning of LED lights Prepare the twisted pair straight through Category 5 cable for Ethernet connection and optic fiber cable for fiber connection NOTE The Fiber port has single mode and multi mode To check 6 I your Industrial media converter fiber connector type look for the sticker on the Industrial media converter The single mode connector type must use 8 125 or 9 125 um single mode fiber cable The connect distance between two devices is up to 30 Km The multi mode connector type must use 50 or 62 5 125 um multi mode fiber cable The connect distance between two devices is up to 2Km Insert one side of Category 5 cables into the Industrial media converter Ethernet port RJ 45 port and another side of category 5 cables to the network switch s Ethernet port RJ 45 port The UTP port RJ 45 LED on the Industrial media converter will light up when the cable connected with the switch Please refer to the LED Indicators section for LED light meaning NOTE Be sure the connected local switch s Ethernet port support MDI MDI X If it does not support then use the crossover category 5 cable Insert one side of fiber cable into the Industrial media converter fiber port and another side to the convert in the opposite side connection The fiber port LED on the converter will light up when the cable 16 connected
6. Signal Name MDI Signal Name oe Receive Data plus RD Transmit Data plus TD Transmit Data plus TD Receive Data plus RD G TN Transmit Data minus TD Receive Data minus RD _ Receive Data minus RD Transmit Data minus TD Switch Router or PC 3 TD es5 RD 6 TD 6 RD RD TD 2 RD 2 TD Straight Through Cable Schematic Switch Switch a TIH 3 IDF 6 TD 6 TD I RD 1 RD 2 RD 2 RD Cross over Cable Schematic 5 E Fiber Port This port is for 100Base FX connections We provide SC fiber connector in multi mode 2Km or single mode 30Km for different model number When you connect the fiber port to another fiber port please follow the below Figure D to connect it Wrong connection will cause the port cannot work normally SC Connector Cable Wirlng SC to C Tx A A Rx Tx B B Rx ATTENTION ATTENTION _ This is a Class 1 Laser LED product Don t stare into AN the Laser LED Beam Cabling m Use the four twisted pair Category 5 cabling for RJ 45 port connection The cable between the converter and the link partner switch hub workstation etc must be less than 100 meters 328 ft 6 long m Fiber segment using single mode connector type must use 8 125 or 9 125 um single mode fiber cable You can connect two devices in the distance up to 30 Kilometers Available on single mode fiber model only m Fiber segment using mult
7. VDC power inputs TX port support Auto MDI MDI X Relay alarm output for port link failure IEEE 802 3x flow control support gt Flow control on full duplex gt Back pressure on half duplex Built in Link Lose Forwarding Technology DIN Rail or wall mountable DIP syvitches to set the operation mode and Link Lost Forwarding function Redundant dual DC power Inputs Package Contents Please refer to the package content list below to verify them against the checklist Industrial 10 100BaseTX to 100BaseFX Media Converter One DIN Rail screwed on the converter One wall mount plate and six screws User manual Industrial 10 100BaseT X to 100BaseFX Media Converter NY AAA Y VVall Mount Plate Screvvs DIN Rail Compare the contents of your industrial media converter vvith the standard checklist above If any item is damaged or missing please contact your local dealer for service Hardware Description In this paragraph we will introduce the Industrial media converters hardware spec port cabling information and wiring installation Physical Dimension Industrial 10 100BaseTX to 100BaseFX Media Converter dimension VV x H x D is 54mm x 135mm x 105mm Front Panel The Front Panel of the Industrial 10 100BaseTX to 100BaseFX Media Converter is showed as Figure 10 100TX to 100FX Media Converter Fiber Port LED Indicator ne PR L LNK ACT sums DIP Switch 3 seti tat r HDX FDX a
8. cet teen seeoeatnead 3 SOPA Ola e ee ee eee eer eee eee eee eee 3 BOHOM VICW suk iodisdon keksa h r t dh 4 PORO aoe E 4 621 0 ae E een AT E eer 6 EED MGIC AION S iesene serrer ko seen ioc 7 DIP SV NG aa naewuneoianeniaanaetdavanepieneniaas 8 Wiring the Power INpUtS aa nana nana ee nene eee eee ee 10 Wiring the Fault Alarm Contact ccccseeeeseeees 11 Mounting Installation ccccceccseeeeeeeeeeeeeees 12 DIN R ATE Mounting ve sec sse con tan ente pa b 12 Wall Mount Plate Moun tin duna u naaaaauaaa nana anen nave neeneee 14 Hardware Installatlon ii aaa aa aaa aaa a ere renea 15 Troubles shooting Technical Specification Introduction Industrial 10 100BaseTX to 100BaseFX Media Converter is a cost effective solution for the converting 10 100Base TX Auto MDI MDIX to 100Base FX cabling It provides the two power inputs that can be connected simultaneously to the DC power sources If one power input fails the other one acts as a backup Industrial 10 100BaseTX to 100BaseFX Media Converter also provides relay alarm outputs to warn when the port link failure so the technician can respond quickly with appropriate emergency operation procedures Also there are DIP switches to set the operation mode for relay alarm Fiber ports link loss forwarding function and UTP operation mode Features UTP to Fiber Media converter Auto Negotiation Speed and Half Full Duplex Support 12 to 48
9. ch is used to configure operation mode for LLF Link Lost Forwarding operation mode for UTP Fiber port and relay alarm operation mode The default value of Dipswitch is OFF Go Easel Ke Enable Port Alarm If the ports link fails the fault LED will light up Disable Port Alarm LLF Enable OFF LLF Disable Link Lose Forwarding When LLF is enabling allow UTP link failures to be reported to the fiber side and also allow Fiber link failure to be reported to the UTP side Therefore A link lost forward feature is provided in both UTP and Fiber side NOTE Please don t change the DIP switch setting when UTP or fiber port is transmitting or receiving data It may cause some data error After change the DIP switch setting must execute Power OFF ON to enable new configures VViring the Povver Inputs Please follow below steps to insert the power wire 1 Insert the positive and negative wires into the V and V connector on the terminal block connector 2 To tighten the wire clamp screws for preventing the DC wires to loose NOTE The wire range of terminal block is from 12 24 AWG VViring the Fault Alarm Contact The fault alarm contact is in the middle of terminal block connector as below figure shows By inserting the wires and set the DIPswitch at ON status it will detect when power is failure or port link failure and form an open circuit And the following figure shows an application example
10. for the fault alarm contact NOTE The wire range of terminal block is from 12 24 AWG Fault Alarm Contact The open circuit will form when the power failure or port link failure 24V DC Buzzer __ 24V Battery The fault alarm device will send a warning signal to warn the user ex alarm sound or flash light Mounting Installation DIN Rail Mounting The DIN Rail is screwed on converter when out of factory If the DIN Rail is not screwed on the converter please see the following Figure F to screw the DIN Rail on the converter Follow the below steps to hang the converter Rear Panel of the converter 1 Use the screws to screw on the DIN Rail on the converter 2 To remove the DIN Rail reverse the step 1 Figure F 1 First insert the top of DIN Rail into the track KT 1 ke eF en F _ s_ Se SS I 3 Check the DIN Rail is tightly on the track 4 To remove the converter from the track reverse step 2 and stepi1 above VVall Mount Plate Mounting Follow the below steps to mount the Industrial media converter with wall mount plate 1 Remove the DIN Rail from the Industrial media converter loose the screws to remove the DIN Rail Place the wall mount plate on the bottom side of the Industrial media converter Use the screws to screw
11. i mode connector type must use 50 or 62 5 125 um multi mode fiber cable You can connect two devices up to 2Km distances Available on multi mode fiber model only LED Indicators There are 8 diagnostic LEDs located on the Front panel of industrial media converter They provide real time information of system and optional status The following table provides description of the LED status and their meanings for the industrial media converter When the industrial switch has power input s the LED will light on No any power No any power inputs e N s No power inputs Off No power inputs No power No power inputs Power failure or UTP port failure or Fiber port failure No Power failure or UTP port failure or Fiber port failure occurs or the port alarm disable se The port is linking vvith its link Green partner LNKJACT The port is transmitting or receivin Fiber Blinks i an 3 packets from the FX device No device attached The port is operating in full duplex Orange mode FDX Fiber SH Half duplex mode or no device attached In 100Mbps transmitting speed 10 100 UTP In 10Mbps transmitting speed The port is linking with its link Green partner LNK ACT The unit is transmitting or receiving UTP Blinks packets from the devices No device attached ae The port is operating in full duplex Orange mode FDX UTP aa Half duplex mode or no device attached DIP switch The DIP swit
12. the wall mount plate on the Industrial media converter Use the hook holes at the corners of the wall mount plate to hang the Industrial media converter on the wall To remove the wall mount plate reverse steps above I converter Hardware Installation In this section we will describe how to install the 101100Base1X to 100BaseFX Media Converter and the installation points for the attention In Figure it is an example application for the Industrial converter Use two Industrial converter fiber port to connect LAN A LAN B in Building A 5th Floor and LAN B i Switch s Ethernet port connect to the Industrial converter s Ethernet port LAN Ain Building A 6th Floor Switch s Ethermet port connect to the Industrial converter s Ethernet port Installation Steps 1 Unpacked the Industrial media converter 2 Check the DIN Rail is screwed on the Industrial media converter If the DIN Rail is not screwed on the Industrial media converter Please refer to DIN Rail Mounting section for DIN Rail installation If you want to wall mount the Industrial media converter then please refer to Wall 15 Mount Plate Mounting section for vvall mount plate installation To insert the Industrial media converter into the track or hang on the wall please refer to the Mounting Installation section Power on the Industrial media converter How to wire the power please refer to the Wiring the Power Inputs section The power