Home
Intelligent Media Converter Hub
Contents
1. copy firmware running firmware tftp command is used to backup current running firmware to TFTP Server at IP XXX XXX XXx xxx as file name in binary format copy firmware tftp running firmware XXX XXX XXX XXX yyy command is used to update the running firmware file from TFTP Server at IP 23 www vseprofttx cz official dealer CZ SK CENTEL s r o 7 2 3 Configure Mode Commands Entering configure command at console interface the prompt will become config All the general settings for the device can be done in this mode If the settings are for ports it is done with interface command in configure mode For example interface ethernet 1 5 is for settings on Port 5 and interface ethernet 1 5 6 10 15 is for settings on Port 5 6 10 11 12 13 14 15 Please refer to next section for the details of this command Enter at the prompt the sub command list will be shown config exit Exit from current mode help Show available commands history Show a list of previously run commands logout Disconnect quit Quit commands aaa AAA Service default Restore to factory default setting end Exit from configure mode hostname Sets system s network name interface Enters privileged interface configuration ip Global IP configuration sub commands logging Modifies message logging facilities managemen
2. 16 7 2 1 Basic of the Console 16 7 2 2 General Basic Commands seen 20 7 2 3 Configure Mode Commands sene 24 7 2 4 Interface Configuring 85 220 0 200000 00 33 7 2 5 Show Commands seien 41 7 3 ABOUT TELNET AND SNMP MANAGEMENT INTERFACES 49 7 3 1 About Telnet Management Interface 49 7 8 2 About SNMP Management Interface 49 7 4 MANAGEMENT WITH HTTP CONNECTION 50 Je NA 52 ente aed vested 57 59 LP M o T 62 JL ENDE T 65 8 TROUBLESHOOTING 67 9 SOFTWARE UPDATE AND 68 A PRODUCT SPECIFICATIONS sine 69 3 www vseprofttx cz official dealer CZ SK CENTEL s r o B 22 eere bete Saahan naian ETa C WARRANT Y 2 00 aiaa 4 www vseprofttx cz official dealer CZ SK CENTEL s r o 1 Introduction CL MCSFP 16M is a management media converter hub with sixteen TX SFP pairs TX ports support 100 1000Mbps operation speed SFP ports supports 100Mbps or 1000Mbps SFP module C
3. is the IP address is the subnet mask For example ip address 192 168 1 12 255 255 255 0 will set the IP address of the device on this VLAN group for remote management ip address renew command is used to refresh the lease time of the IP address got by DHCP If IP configuration is not got when boot up this command will try to get IP configuration again ip address release command is used to release current IP address got by DHCP Then you can try to get the IP configuration again by ip address renew command ho command This command is used to disable a function or restore a setting to factory default of the device config if no ip Internet protocol For example ip address dhcp command can enable DHCP client function on the VLAN group interface and no ip address dhcp command can disable it ip address y y y y command can set the IP address x x x x on the VLAN group interface and no ip address command can set it to default settings 192 168 1 1 40 www vseprofttx cz official dealer CZ SK CENTEL s r o 7 2 5 Show Commands Show command is put in General Basic Commands for viewing system configuration and information Enter show at the prompt the sub command list will be shown show aaa Show AAA service configuration calendar Date and time information history History information interface Interface information ip IP information line TTY line infor
4. Speed 37 www vseprofttx cz official dealer CZ SK CENTEL s r o 7 2 4 2 Interface Configuring Commands for VLAN Commands in Configuring Mode are for general device settings And its prompt is config If the characteristics are for VLAN it is done with interface vlan x command in configure mode For example interface vlan 1 is for characteristics settings on VLAN 1 Entering interface vlan 1 and its prompt will become config t interface vlan 1 config if Enter at the prompt the sub command list will be shown config if exit Exit from current mode help Show available commands history Show a list of previously run commands logout Disconnect quit Quit commands interface Enters privileged interface configuration ip Internet protocol no Negates a command or sets its defaults _ exit command This command is used to leave current operation mode Go back to last mode 2 help command This command is used to show all the available commands in this mode 3 history command This command is used to show the history of entering commands 4 logout command This command is used to logout from console interface 38 www vseprofttx cz official dealer CZ SK CENTEL s r o 5 6 N quit command This command is used to quit from console interface It has the same function as logout interface command This command is used to change to interface port s or another interface VLAN for
5. Product Specifications Access Method Ethernet CSMA CD Standards Conformance IEEE802 3u 100Base Fast Ethernet IEEE802 3ab 1000BaseT IEEE802 3z 1000Base Number of Ports 16 RJ45 TX ports 16 SFP ports Each TX SFP pair works individually 1 10 100Mbps RJ45 TX Management Port Indicator Panel each unit Power each port Link Act Speed Green 1000M Yellow 100M LAN port Link Act Speed Green 100M Yellow 10M Dimensions 440 x 171 x 43 mm 1U Certification CE Mark FCC Class A Temperature Standard Operating 0 to 50 C Humidity 10 to 9096 Non condensing Power Input AC model 100 240VAC 50 60Hz DC model 36 72VDC Operation Method Pure converter mode Link Pass Through Yes Communication Rate 100Mbps or 1000Mbps depending on link speed on SFP port auto detect MDI MDIX Auto detect on TX ports SFP Interface Gigabit SerDes or 100BaseFX Traffic Rate Line speed Admin Manage SecurityYes by IP Subnet Protocol interface limit Admin Authentication Yes by local or Radius Server System Time Yes by NTP protocol support Daylight Saving System Log Yes Local and Remote by syslog logging Up to 5 syslog servers are supported DDMI Yes support SFP module DDMI information status monitor 69 www vseprofttx cz official dealer CZ SK CENTEL s r o Out band Management Console Telnet Http Https SNMP SNMP Agent Ver 1 2c 3 Supports MIB 1213 Private MIB Software Update Backup by http TFTP protocols X
6. 6 www vseprofttx cz official dealer CZ SK CENTEL s r o lt lt Rack Mount Installation gt gt Before rack mounting the device please pay attention to the following factors 1 Temperature Because the temperature in a rack assembly could be higher than the ambient room temperature check that the rack environment temperature is within the specified operating temperature range Please refer to Product Specifications in the manual Air flow is necessary in a rack for temperature stable 2 Mechanical Loading Do not place any equipment on top of this rack mounted device 3 Circuit Overloading Be sure that the supply circuit to the rack assembly is not overload after installing this device 4 Grounding Rack mounted equipment should be properly and well grounded Particular attention should be given to supply connections other than direct connections to the mains Attach Rack Mount Brackets to the Device D 3 6 7 Ler 9 9 1 Position a Rack Mount Bracket on one side of the device 2 Line up the screw holes on the bracket with the screw holes on the side of the device 3 Use a screwdriver to install the M3 flat head screws through the mounting bracket holes into the device There could have two or four screws for one bracket That depends on the model that installed 4 Repeat Step 1 3 to install another bracket to the device 5 Now it is ready to mount to a rack 7 www vseprofttx cz official dealer CZ SK CENTEL
7. Client renew and release button renew button If DHCP client function is enabled you can click renew button to refresh the lease time of the IP address If IP configuration is not got when boot up clicking renew button will try to get IP configuration again release button If DHCP client function is enabled and IP configuration is got clicking release button will release current IP configuration After that you can click renew button to get the IP configuration again 53 www vseprofttx cz official dealer CZ SK CENTEL s r o 7 4 1 3 Time Configuration Dur uu m m o o o o m o n n un f ma mn mn 5 mn n n jm n n n n m m mm Time Configuration Time Configuration Get Time By C rime Server Manually Daylight Saving Time Disable C Enable Eg System Start Time SUN JAN xat 000 E E System Information End Time SUN lof JAN lat 0 00 E 8 Configuration Time Server IP 220 130 158 54 1 Time Configuration Time Zone Mame El SB Log vp 2 9 SNMP Current Time S Security Bp mp 3 Port Apply g Tools There are two ways to get the system time 8 Get time from Time Server This device support NTP protocol to get time from Internet time server For such application you have to select Get Time by Time Server input the IP of Time Server and select the Time Zone of your location Then click Apply If
8. DDMI of SFP modules and port link up down status could be monitored through the management interface The following is a brief introduction about these functions before the detail operation sections 1 DDMI of SFP module DDMI Digital Diagnostics Monitoring Interface is a function for network device information and status monitor If a SFP module supports DDMI function this device can read the information and status of the SFP module If alarm or warning conditions happen this device will send a SNMP trap 2 Link Pass through For a TX SFP pair the link status of TX or SFP port will be passed through to another side to make the link status being transparent 3 Logging and syslog Logging function can record system events to flash That is helpful for system diagnostics And syslog function can send the event log to a remote server through syslog protocol 4 Software Backup Update This device supports backup and update functions for its internal software and its network configuration could be done in two ways a From console when booting doing by Xmodem protocol and by terminal program for boot code and run time code updating b From web browser doing by http protocol and by web browser for 14 www vseprofttx cz official dealer CZ SK CENTEL s r o run time code and configuration backup update c From telnet or console command doing by tftp protocol for run time code and configuration backup update 15 www vseproft
9. SNMP instead 12 logging command This command is used to configure logging function of the device The logging function can record events at local flash or remote log server Entering logging the sub commands will be shown config logging log level Log level on Enable logging to all supported destination remote log Enable logging to remote host clear Clear logging table information logging log level x command is used to define the log level of events The valid value of x is 0 7 logging on command is used to enable the logging function And no logging on command is used to disable the logging function logging remote log command is used to configure remote logging function Entering logging remote log the sub commands will be shown config logging remote log 1 5 Index cr logging remote log command is used to enable the remote logging function Events will also be sent to syslog servers no logging remote log command is used to disable it logging remote log x host y y y y command is used to set IP 27 www vseprofttx cz official dealer CZ SK CENTEL s r o address y y y y for syslog server indexed x Up to five x 1 5 Syslog servers are supported logging clear command is used to clear log table 13 management command This command is used to setup management interface security function The management interface security function can limit the IP subnet remote interfaces http te
10. Server 220 130 158 54 Time Zone Japan 9 37 Current Time 2011 01 01 12 45 12 D S T status Disable D S T start 1st SUN JAN 0 00 D S T end 1st SUN JAN 0 00 47 www vseprofttx cz official dealer CZ SK CENTEL s r o 13 show system command This command is used to show general system information configuration of the device For example show system System Configuration Main Board Information Firmware Version 1 00 01 built at Jun 2 2011 10 50 54 Mac Address 00 00 00 00 00 88 Number of Ports 16 DHCP Client Disable Time Server Disable System Log Status Enable Remote Log Disable Web server Enable Web server port 80 Web secure server Disable Web secure server port 443 14 show version command This command is used to show system version information and model information For example show version Firmware Version 1 00 01 built at Jun 2 2011 10 50 54 Number of Ports 16 Model Name CL MCSFP 16M 48 www vseprofttx cz official dealer CZ SK CENTEL s r o 7 3 About Telnet and SNMP Management Interfaces 7 3 1 About Telnet Management Interface If you want to use Telnet to manage the device from remote site you have to set the IP NetMask Gateway address to the device first from console Then use telnet lt IP gt command to connect to the device Its operation interface is the same as console interface 7 3 2 About SNMP Management Interface If you want to use NMS to managem
11. commands will be shown config snmp server 1 5 Index of Trap community Defines SNMP community access string contact Sets the system contact string location Sets the system location string username Sets the snmpv3 user informations version Sets the snmp version snmp server community get xxx command is used to set the community string of get command for SNMP operation xxx is the community string snmp server community set xxx command is used to set the community string of set command for SNMP operation xxx is the community string snmp server contact xxx command is used to set the contact information for this device xxx is the contact information string snmp server location xxx command is used to set the location information for this device xxx is the location information string snmp server version x command is used to select the SNMP operation version x could be v1 v2c v3 v3v2c v3v2cv1 The following commands are for SNMPv3 function 30 www vseprofttx cz official dealer CZ SK CENTEL s r o snmp server username xxx securitylevel y command is used set security level of user xxx xxx is the user name y could be noauth auth or priv noauth no authentication no encryption auth do authentication no encryption priv do authentication and encryption by DES snmp server username xxx authentication y command is used to set the authentication manner xxx
12. default encryption for privacy is by DES The security level could be noauth no authentication no encryption auth do authentication no encryption priv do authentication and encryption by DES The authentication manner could be MD5 or SHA 58 www vseprofttx cz official dealer CZ SK CENTEL s r o 7 4 3 Security This function is used to configure security functions of the device The security functions are Administrator Management Security 7 4 3 1 User Accounts Administrator Management Security eT o o T m o m D m m D P n oe Admin Configuration CL MCSFP 16M 1 00 01 buil Admin Username Password Old Username Old Password System New Username HE SNMP Security New Password au 9 User Accounts Confirm Password 8 Radius Server Apply m3 Port Tools Guest Username Password Username gest Password zvest Administrator Username Password This is for network administrator to change his her username and password Default is admin admin Guest Username Password This is used to setup the username password for guest right user who just can view the setting of the device 59 www vseprofttx cz official dealer CZ SK CENTEL s r o Username asst Passwor
13. enable link pass through function of the TX SFP pair Link pass through function can make the link status of TX port and SFP port follow each other Only both of them are link up then they will be link up That will make the link status being transparent after media conversion no Ipt command can be used to disable it 10 no command This command can do the following settings And it depends on the command after it 1 Disable a function 2 Restore a setting to factory default of the device 3 Clear a setting For example description abc will set the description of the port s as abc And no description will clear this setting 4 Remove port s from a function Here is the sub Commands config if no description Interface specific description 36 www vseprofttx cz official dealer CZ SK CENTEL s r o 11 shutdown command This command is used to disable the interface port s shutdown command is used to disable the interface port s no shutdown command is used to enable it 12 speed command This command is used to set the operation speed of the interface port s config if speed auto Set port speed to be auto 100 Set port speed to be 100M 1000 Set port speed to be 1G speed auto command will set the interface port s to auto detect 100M or 1000M operation speed speed 100 command will set the interface port s to 100M speed speed 1000 command will set the interface port s to 1000M gigabit
14. is the user name y could be md5or sha 18 sntp command This command is used to configure SNTP protocol of the device Entering sntp the sub commands will be shown config sntp client Accepts time from specified time server server Specified one time server zone Set time zone dst Config daylight saving time function start time Set start time of daylight saving time end time Set end time of daylight saving time sntp client command is used to enable SNTP protocol And no sntp client command can be used to disable it If it is disabled the system time will be got from manual setting sntp server x x x x command is used to set the IP address of network time server for SNTP protocol operation x x x x is the IP address sntp zone xxx command is used to set the time zone xxx is the location of the time zone With sntp zone the locations will be shown sntp dst command is used enabled Daylight Saving Time function And no sntp dst command can be used to disabled it Daylight Saving Time function will set the system time one hour early than normal time in a period of time start time and end time sub commands can be used to set the time period sntp start time w X y z command is used to set the start time of sien Saving Time is the week number in the month Its value is 1 5 is the day number in the week Its value is 0 6 is the month number Its value is 1 12 27 is th
15. next setup commands config if interface ethernet Ethernet port vlan Virtual LAN interface For example config interface ethernet 1 5 will change the setup interface to Port 5 and all the following commands will be applied to Port 5 config if interface ethernet 1 6 7 will change the setup interface to Port 6 7 and all the following commands will be applied to Port 6 7 If vlan sub command is used the setup interface will be changed to some VLAN For example config if interface vlan 100 will change the setup interface to VLAN 100 and all following commands will be applied to VLAN 100 The description of commands in interface configuring mode is put in Section 7 2 4 Interface Configuring Commands Please refer to the section for the details ip command This command is used to set IP address of the device on this VLAN interface And only users in this VLAN can access this device with the IP address remotely config if ip address dhcp Dynamic host configuration protocol A B C D IP address renew Renew IP release Release IP ip address dhcp command is used to enable DHCP client function DHCP client function will try to get IP configuration from DHCP server in network And no ip address dhcp command can be used to disable it 39 www vseprofttx cz official dealer CZ SK CENTEL s r o ip address x x x x y y y y command is used to set IP address of the device on this VLAN x x x x
16. radius server command This command is used to configure the settings of RADIUS Server for administrator authentication operation This device supports two RADIUS Servers for redundant applications Entering radius server x x 1 for first RADIUS Server x 2 for second RADIUS Server the sub commands will be shown config radius server active Active the RADIUS server host Specifies the RADIUS server 29 www vseprofttx cz official dealer CZ SK CENTEL s r o key Sets the RADIUS encryption key port Sets the RADIUS server network port radius server x active command is used to activate RADIUS Server x is 1 or 2 x 1 for first RADIUS Server x 2 for second RADIUS Server radius server x host y y y y command is used to set the IP address of RADIUS Server x x is 1 or 2 x 1 for first RADIUS Server x 2 for second RADIUS Server is the IP address radius server x key yyy command is used to set the security key to handshake with RADIUS Server x x is 1 or 2 x 1 for first RADIUS Server x 2 for second RADIUS Server is the key string radius server x port y command is used to set the communication port of RADIUS Server x is 1 or 2 x 1 for first RADIUS Server x 2 for second RADIUS Server y is the port number and its valid value is 1 765535 17 snmp server command This command is used to configure SNMP operation of the device Entering snmp server the sub
17. time is got from Time Server it will be shown at Current Time For such application you have to get the IP of Time Server from your network administrator first b Set time manually This device can count time internal You can select Get Time by Manually and input current time manually Then click Apply About Daylight Saving Time Daylight Saving Time function will set the system time one hour early than normal time in a period of time Start Time and End Time can be used to set the time period 54 www vseprofttx cz official dealer CZ SK CENTEL s r o 7 4 1 4 Log Configuration br wr o o o o o o i w wm mn m 0 mn mn n n n n m m m mn 1 System Log Configuration System Log Status Enable C Disable Log Level 0 7 7 SS System 8 System Information S Configuration S Time Configuration Remote Log Server IP 2 Remote Log C Enable Disable Remote Log Server IP 1 59 Log Remote Log Server IP 3 181 Configuration 18 Log Table EG SNMP Remote Log Server IP 5 S Security RE aS Port Tools Remote Log Server IP 4 Users can configure System Log function and view log records here If this function is enabled the device will record events to a log file in flash Up to 512 records are allowed for local logging If more than 512 events happen the records will be overwritten from beginning And if remote syslog server is applied the device will also
18. ways 1 From console when booting by Xmodem protocol and doing by terminal program This function can be used for run time code and boot code updating Boot code works only at boot time before the main program starts Press Ctrl C when the device is booting the following message will be shown Boot Menu 0 Start the Run time code 1 Upgrade Run time code 2 Upgrade Boot Code Select a Start Run time code This option will continue the booting process b Upgrade Run time code This option will try to update run time code main code from terminal program with Xmodem protocol If this option is selected the following message will be shown Waiting to receive file by Xmodem Then user can select Send File function of terminal program and select Xmodem protocol and the update file then start the file upgrade c Upgrade Boot Code This option will try to update boot code from terminal program with Xmodem protocol User can select Send File function of terminal program and select Xmodem protocol and the update file then start the file upgrade 2 From web browser Doing by http protocol and by web browser Please refer to the description of Tools function in Section 7 4 12 3 From console telnet command Doing by tftp protocol and done by copy command Please refer to the description of command in Section 7 2 2 68 www vseprofttx cz official dealer CZ SK CENTEL s r o A
19. 2004 108 EC Warning Do not plug a phone jack connector into the RJ 45 port This may damage this device 71 www vseprofttx cz official dealer CZ SK CENTEL s r o C Warranty We warrant to the original owner that the product delivered in this package will be free from defects in material and workmanship for a period of warranty time from the date of purchase from us or the authorized reseller The warranty does not cover the product if it is damaged in the process of being installed We recommend that you have the company from whom you purchased this product install it 72 www vseprofttx cz official dealer CZ SK CENTEL s r o
20. 3 And all the settings will be applied to those ports at the same time The description of commands in interface configuring mode is put in Section 7 2 4 Interface Configuring Commands Please refer to the section for the details 11 ip command This command is used to configure some IP depending functions Entering ip the sub commands will be shown config ip default gateway Specifies the default gateway http HTTP server configuration ip default gateway x x x x command is used to specify the default gateway of IP configuration of the device x x x x is the IP address of 26 www vseprofttx cz official dealer CZ SK CENTEL s r o the gateway device ip http command is used to configure http service of the device Entering ip http the sub command will be shown config ip http Secure server Enable secure HTTP server server Enable HTTP server ip http secure server command is used to enable the SSL function of http service https of the device And no ip http secure server command can be used to disable it ip http server command is used to enable http service of the device And no ip http server command can be used to disable it Because hacker or worm virus like ColdRed often attacks http server this command is provided to enable disable http service to prevent it If this device is installed in public Internet without any firewall protection we suggest users to disable the http interface and use Telnet or
21. 4 5 Tools The follow functions are used for system maintenance They are Software Upgrade Configuration Backup Restore Restore Factory Default Reset System and Ping functions 7 4 5 4 Tools Information Four functions are supported as the system maintenance tools N OOOOCOOOCOOOCOOCAL He 2 Maintenance Tools CL MCSFP 16M 1 00 01 built at Jun 2 201 0 50 54 Firmware Upgrade Enter the path and name of the upgrade file then click the START button EC System i ae Config Backup Restore EC Security Please press the Backup Setting button to save the configuration data to your pc BI Port Backup Setting Backup Seting Tools Enter the path and name of backup file then press Restore Setting button 19 Ping Restore Factory Default Please press the Restore button to restore the factory default settings of the Device Restore Reset System In the event that the Device stops responding correctly or in some way stops functioning you can perform a reset Please press the Reset button Reset Firmware Upgrade This function will upgrade the system operation software from the web management PC Config Backup Restore Backup Setting Clicking this button the device will backup the configuration of the device to the web management PC Backup Setting to text file Clicking this button t
22. L MCSFP 16M will auto detect link speed on SFP port and set TX port to the same operation mode If SFP port link down and link pass through function is enabled TX port will also force to link down Management functions are supported with Http CLI and SNMP interfaces for device configuration and monitor CL MCSFP 16M is a smart and cost effect Fast Ethernet Gigabit Ethernet copper to SFP converter device It is powerful and flexible for network installation 1 1 Package Contents Y One CL MCSFP 16M Y This user manual Y One AC power Cord AC power model only Y Rack mount kits and screws Y One console cable 5 www vseprofttx cz official dealer CZ SK CENTEL s r o 2 Where To Place the Device This device can be placed on a flat surface your desk shelf or table Place the device at a location with these connection considerations in mind The device configuration does not break the rules as specified in Section 3 The device is accessible and cables can be connected easily to it The cables connected to the device are away from sources of electrical interference such as radio computer monitor and light fixtures There is sufficient space surrounding the device to allow for proper ventilation the device may not function according to specifications beyond the temperature range of 0 to 50 degrees C You can install the device on a 19 rack with rack mount kits as the picture
23. MCSFP 16M User s Manual Rev 1 10 www vseprofttx cz official dealer CZ SK CENTEL s r o We make no warranties with respect to this documentation and disclaim any implied warranties of merchantability quality or fitness for any particular purpose The information in this document is subject to change without notice We reserve the right to make revisions to this publication without obligation to notify any person or entity of any such changes Trademarks or brand names mentioned herein are trademarks or registered trademarks of their respective companies 2 www vseprofttx cz official dealer CZ SK CENTEL s r o Contents T INTRODUCTION 211 rure ren tend c eue rte et nnuee 5 1 1 PACKAGE CONTENTS ostr teta leet Ge e Dd e utem te 5 2 WHERE TO PLACE THE 6 3 CONFIGURE NETWORK CONNECTION 9 3 1 CONNECTING TO THE DEVICE 9 2 2 nii puta iaia n ie 10 4 ADD REMOVE SFP nn 11 5 LED CONDITION DEFINITION inner 12 5 1 LED INDICATION cecinere fte 12 6 OPERATION OF THE DEVICE eren 13 7 MANAGE CONFIGURE THE DEVICE nennen 14 7 1 INTRODUCTION OF THE MANAGEMENT FUNCTIONS 14 7 2 SETTINGS WITH CONSOLE
24. al device first when login by http s telnet for management If authentication fail try by RADIUS Server next RADIUS Server is set by radius server command for command line interface or set in Security function for web interface 7 default command This command is used to restore factory default settings Before start it a confirm message wil be prompted 8 end command This command is used to exit from configure mode 25 www vseprofttx cz official dealer CZ SK CENTEL s r o 9 hostname command This command is used to set the name of the device in network This name is also used as the hostname for SNMP agent function of the device 10 interface command This command is used to entering interface configuring mode There are two sub commands for it one is ethernet it is for port setting another is vlan it is for device IP address setting on VLAN config interface ethernet Ethernet port vlan Virtual LAN interface All the port setting commands are put in interface configuring mode like port name And characteristics settings for VLAN are also done in interface configuring mode like IP address assignment For example the console will enter interface configuring mode for Port 5 with interface ethernet 1 5 command And the prompt will become config interface ethernet 1 5 config if With interface ethernet 1 5 6 10 13 the console will enter interface configuring mode for Port 5 6 10 11 12 1
25. and vlan IP address of the device can be configured in this mode 17 www vseprofttx cz official dealer CZ SK CENTEL s r o interface vlan 1 xxxx config if guest mode If guest guest is used for username password the console interface will enter guest mode Its prompt is ended with gt With command you can find the command list as follow 27 exit Exit from current mode help Show available commands history Show a list of previously run commands logout Disconnect ping Sends ICMP echo packets to other network nodes quit Quit commands show Shows information gt In guest mode it is allowed to view the device configuration only No setup configure commands are supported lt lt Function Keys gt gt Here is the function keys for console interface Tab key this key can help to get the full command keyword with just several beginning letters For example cal Tab will get the full calendar command word Esc key this key can use to break message display and go back to command prompt Up Arrow key this key can get last input command Down Arrow key this key can get next input command Left Arrow Right Arrow key the key can move the cursor Backspace key this key can delete the letter in front of cursor key this key can get the command list Command Mode There are three command modes for console interface 18 www
26. cable application is popular now this device provides an easy way to convert it to copper cable that is used for most network device connections The example below demonstrates the device ability to connect a network Number of nodes are connected with Ethernet fiber optic cables With the device they are connected to a normal Ethernet switch and switching network traffic there If fiber optic cable connection fail copper connection will also be link down to pass down the problem if link pass through function is enabled Complete the network connection and do some simple configuration Then it works and could be monitored remotely uy File Server File Server Fiber Optic Cables with Long Distance Fiber Optic Cables with Long Distance PowerUser 1 Workgroup Workgroup 10 www vseprofttx cz official dealer CZ SK CENTEL s r o 4 Add Remove SFP Module This device supports SFP module 100FX 1000SX 1000LX network connection Because SFP slots support hot swap function you can plug unplug SFP transceiver to from SFP slot directly The device can auto detect the Ethernet connection from SFP slot Follow the steps for module adding and removing Add SFP Transceiver 1 Plug in the SFP Transceiver to SFP slot directly 2 Connect network cable to the SFP Transceiver If the connected devices are working and TX port of the pair is ready for
27. command 10 configure command This command will change the console interface to configure mode And the prompt will become config In this mode administrator can do system configuration of the device The operation of configure mode will be described in next section exit command can be used to quit this operation mode 11 copy command This command is used to backup system configuration firmware to TFTP server restore system configuration from TFTP server and update firmware from TFTP server 22 www vseprofttx cz official dealer CZ SK CENTEL s r o copy binary config Copies binary configuration file config Copies configuration file firmware Copies run time firmware copy binary config running config tftp xxx xxx xxx xxx yyy command is used to backup current device running configuration to TFTP Server at IP xxx xxx xxx xxx as file name yyy in binary format copy binary config tftp running config command is used to restore binary configuration file from TFTP Server at IP XXX XXX XXX XXX copy config running config tftp xxx xxx xxx xxx yyy command is used to backup current device running configuration to TFTP Server at as file name in text format copy config tftp running config xxx xxx xxx xxx yyy command is used to restore text configuration file from TFTP Server at IP
28. connection will be shown in the following sub sections 51 www vseprofttx cz official dealer CZ SK CENTEL s r o 7 4 1 System System Information is the homepage of the device And there are four sub functions for it 7 4 1 1 System Information bur wr ue o e o m m o w mm mn n n n n n n n n m n m m n System Information Firmware Version 1 00 01 built at Jun 2 2011 10 50 54 Mac Address 00 00 00 00 00 88 Number of Ports 16 8 System Information 8 IP Configuration 8 Time Configuration Eg Log SNMP Security Gy Port Eg Took This function lists the system information about the device You can find the firmware version Mac address and connection port number here 52 www vseprofttx cz official dealer CZ SK CENTEL s r o 7 4 1 2 IP Configuration gt n o o o o n n f Lo mn mn 55 n n n n n n n n n I IP Configuration jetwork Configurat DHCP Client C Enable Disable renew release IP Address 192 168 1 156 Network Mask 255 255 255 0 System 8 System Information Gateway 192 168 1 254 8 Configuration Apply 18 Time Configuration This function is used to setup IP configuration of the device You can enable DHCP client function to get IP configuration from DHCP server automatically Or disable DHCP client function and set IP configuration manually About DHCP
29. d guest EHI Login local qm Eg Pot Bg Tools Security Policy Note If no http is selected Web management will become disable If no modify is selected setting configuration will become disable t Address Net Mask 1 v 0000 0000 M t 2 0 0 0 0 255 255 255 255 View 3 0000 258282528 4 0000 255 255 255 255 View Authentication This is used to configure authentication for administrator when login It could be local radius or local radius local authentication is done by local radius authentication is done by RADIUS Server local radius authentication is done by local first Then authentication is done by RADIUS Server if local authentication fails Security Policy This is used to setup the IP addresses of administrators that can manage this device They have different access rights set in Mode And the remote management interfaces Http Telnet SNMP could enable disable for different administrators This function is for security policy of device management Note Remember to enable at least one IP Subnet with Modify right for Http Telnet SNMP interface Otherwise configuring device from remote will become impossible In that case you can manage the device from console only 60 www vseprofttx cz official dealer CZ SK CENTEL s r o 7 4 3 2 RADIUS Server bu ur o m o e o o c m mn n mn n n n n n n n m m
30. e hour number in the day Its value is 0 23 sntp B time w x y z command is used to set the end time of Daylight Saving Time 31 www vseprofttx cz official dealer CZ SK CENTEL s r o the week number the month Its value is 1 5 is the day number in the week Its value is 0 6 is the month number Its value is 1 12 27 is the hour number in the day Its value is 0 23 19 username command This command is used to set the username and password for administrator and guest username admin www xxx yyy zzz command is used to set the username and password for administrator www is the old username is the old password is the new username 222 is the new password username guest yyy zzz command is used to set the username and password for guest yyy is the new username zzz is the new password Administrator is the user who has the right to do configuration modification Guest is the user who has the right to view configuration only 32 www vseprofttx cz official dealer CZ SK CENTEL s r o 7 2 4 Interface Configuring Commands Commands in Configuring Mode are for general device settings And its prompt is config The port interface function and VLAN interface function are set with interface command config t interface ethernet Ethernet port vlan Virtual LAN interface interface ethernet 1 x command is used to configure sett
31. ent the device from remote site you have to set the IP NetMask Gateway address to the device and configure the SNMP setting of the device from console first Then you can use SNMP management program to manage this device This device supports SNMP v1 v2c and v3 agent function and MIB I Interface Private MIB default GET community name is public and SET community name is private This device supports up to five trap receivers with different trap community names 49 www vseprofttx cz official dealer CZ SK CENTEL s r o 7 4 Management with Http Connection Users can manage the device with Http Web Browser connection The default IP setting is 192 168 1 1 and NetMask 255 255 255 0 The default IP Gateway is 192 168 1 254 Before http connection IP address configuration of the device could be changed first 1 Please follow the instruction in Section 7 2 to complete the console connection 2 Login in with admin password is also admin by default 3 Use show ip interface command to check IP address of the device first 4 If IP address needs to be changed follow the steps 4 1 Enter config command and the prompt will become config 4 2 Enter interface vlan 1 command and the prompt will become config if 4 3 Enter ip address command XXX XXX XXX xxx is the IP address and yyy yyy yyy yyy is the netmask to modify IP addres
32. ers ethernet 1 3 Port 1 3 TX Port Counter Statistics Receive Good Packet 0 Receive CRC Error Packet 0 SFP Port Counter Statistics Receive Good Packet 0 Receive CRC Error Packet 0 show interface mgmtport command will show current management LAN port link status show interface status command will show port status of all ports one after another show interface status ethernet 1 x command will show port status of Port X is the port number For example show interface status ethernet 1 3 Information of Eth 1 3 Name Port 3 Admin Enable Speed Auto Link Pass through Enable TX Link DOWN SFP Link DOWN 42 www vseprofttx cz official dealer CZ SK CENTEL s r o show interface switchport command will show DDMI information status of all ports one after another show interface switchport ethernet 1 x command will show DDMI information status of Port x x is the port number For example show interface switchport ethernet 1 1 Digital Diagnostics Monitoring Interface of Eth 1 1 Serial Info Table Status ok with DDM Vendor XXXXXXXX PartNo XXXXXXXX SerialNo XXXXXXXX Revision DateCode XXXXXXXX Transceiver 1000BASE SX Ddm Info Table Type AlarmMax AlarmMin WarnMax WarnMin Current 0 01 9500 3200 9000 2500 4212 Voltage 0 01mV 363 297 356 304 331 TxBias 0 01mA 1300 200 1200 300 816 TxPower 0 01mW 79 12 63 14 35 RxPower 0 01mW 100 2 79 3 0 5 show ip com
33. he device will backup the configuration of the device to the web management PC in text format Restore Setting The configuration of the device can be restored to device by clicking this button after the configuration file is selected Restore Factory Default This function will restore the device configuration to factory default setting Reset System This function will cause the device to reboot itself 65 www vseprofttx cz official dealer CZ SK CENTEL s r o 7 4 5 2 Ping bw e e o o o o o m o o o o 0 mn mn mn 55 n n n n mn n n n m m mn Ping Parameters This function is used to ping network devices from the device can be used to verify network connection Target IP address This is the target IP address for the ping operation Count This is the repeat count for the ping operation Time Out This is the timeout value for the ping operation After the above items are set click Apply to start the ping operation Then the result of ping operation will be shown 66 www vseprofttx cz official dealer CZ SK CENTEL s r o 8 Troubleshooting Guide Power LED is OFF 1 Check the power connection SFP port LED is OFF 1 SFP module should be inserted correctly 2 Check the cable connection and link status at both sides of cable The connection of another side of cable should be ready for link up 3 Operation mode at both sides should be the same 1000Mbps or 100Mbps Single M
34. ill be shown show aaa Show AAA service configuration calendar Date and time information history History information interface Interface information ip IP information line TTY line information log Log records management Management IP filter radius server RADIUS server information running config Information on the running configuration snmp Simple Network Management Protocol statistis sntp Simple Network Time Protocol configuration system System information 21 www vseprofttx cz official dealer CZ SK CENTEL s r o version System hardware and software versions With sub commands function configuration settings will be displayed And more help information for functions will be prompted with show xxxx xxxx is the sub command For example entering show ip will get the prompt message show ip interface Interface information redirects Default gateway configured for this device And entering show ip redirects will get the gateway settings show ip igmp redirects gateway 192 168 1 254 If the display is more than one console page Esc can be used to break the display For the details please refer to section 7 2 6 Show commands 9 calendar command This command is used to set the system time It is entered in hour minute second month day year order For example calendar set 10 30 0 october 15 2008 show calendar Current Time 2008 10 15 10 30 18 It is 18 seconds passby after the setting
35. ings for Port x Please refer to section 7 2 4 1 Interface Configuring Commands for Port for the details interface vlan x command is used to configure VLAN x x is the VLAN ID Please refer to section 7 2 4 2 Interface Configuring Commands for VLAN for the details Both commands will change the prompt from config to config if 33 www vseprofttx cz official dealer CZ SK CENTEL s r o 7 2 4 1 Interface Configuring Commands for Port Commands in Configuring Mode are for general device settings And its prompt is config If the settings are for ports it is done in port interface configuring mode Port interface configuring mode is entered with interface ethernet 1 x command in configure mode For example interface ethernet 1 5 is for settings on Port 5 Some syntax are supported for port selection 1 interface ethernet 1 x and is port number All the settings after this command will be applied to this port For example interface ethernet 1 5 and all the settings after this command will be applied to Port 5 interface ethernet 1 x y z and x y z are port number All the settings after this command will be applied to these ports For example interface ethernet 1 2 4 7 and the settings after this command will be applied to Port 2 Port 4 and Port 7 interface ethernet 1 x y and are port number All the settings after this command will be applied to p
36. is used to show current system log configuration For example show log configuration System Log System Log Status Enable Log Level 0 7 7 Remote Log Disable Remote Log Server IP Empty Remote Log Server IP Empty Remote Log Server IP Empty Remote Log Server IP Empty Remote Log Server IP Empty 44 www vseprofttx cz official dealer CZ SK CENTEL s r o 8 show management command This command is used to show device management security settings The IP subnet access mode and protocol functions security settings will be shown For example show management Management IP configuration Index Enabled Address Net Mask Mode Http Telnet SNMP 1 Yes 0 0 0 0 0 0 0 0 Modify Yes Yes Yes 2 No 0 0 0 0 255 255 255 255 View No No No 3 No 0 0 0 0 255 255 255 255 View No No No 4 No 0 0 0 0 255 255 255 255 View No No No 9 show radius server command This command is used to show settings of RADIUS Server for administrator authentication operation For example show radius server Server 1 Active Yes IP Address 192 168 1 222 Port Number 1812 Security Key 12345678 Server 2 Active Yes IP Address 192 168 1 222 Port Number 1812 Security Key 12345678 10 show running config command This command is used to show current running configuration of the device For example show running config Ibuilding running config please wait sntp server 220 130 158 54 sntp zone japan 45 w
37. link up the Link Act Speed LED will be ON Remove SFP Transceiver Unplug the SFP Transceiver from SFP slot directly 11 www vseprofttx cz official dealer CZ SK CENTEL s r o 5 LED Condition Definition 5 1 LED Indication The LEDs provide useful information about the device and the status of all individual ports LED Status Description ON The device is power ON Power OFF The device is power OFF ON Green The port is link as 1000Mbps speed ON Yellow The port is link as 100Mbps speed Link Speed Act Flash Green Send Receive data in 1000Mbps Flash Yellow Send Receive data in 100Mbps OFF The port is link down ON Green The port is link as 100Mbps speed ON Yellow The port is link as 10Mbps speed LAN Flash Green Send Receive data in 100Mbps Management Flash Yellow Send Receive data in 10Mbps OFF The port is link down 12 www vseprofttx cz official dealer CZ SK CENTEL s r o 6 Operation of the Device This device consists of sixteen TX SFP pairs Each pair works individually from each other Each TX SFP pair works in pure converter mode convert the connection media at SFP port to copper TX connection No any packets will be blocked or filtered in the media conversion Here is the description about its operation 1 Detect the connection at SFP port When SFP module is plugged into a SFP slot and network cable is connected the device will detect the link s
38. lnet snmp access right view modify for management from network Different administrators could have different rights to manage this device This is for security of this management device Four user groups are supported for this function Entering management the sub commands will be shown config management 1 4 Index config management 2 enable Set enable for a specified set ipaddr Set IP and net mask for a specified set mode Set mode for a specified set protocol Set protocol for a specified set management x enable command is used to enable the security settings for some user groups x is the index of the user group no management x enable command can be used to disable it And users in this group are allowed to manage this device remotely management x ipaddr y y y y 2 2 2 2 command is used to set the IP subnet for some user groups x is the index of the user group is the IP address 2 2 2 2 is the IP subnet mask Users in this IP subnet will belong to this users groups management x mode modify view command is used to set the access right for some user groups x is the index of the user group If management x mode modify command users in this groups have modify right for management If management x mode view command users in this groups have view right only management x protocol http snmp telnet command is used to enable the remote management protocol fo
39. m m Radius Server Configuration Index Active IP Address Port Number Security Key 1 vi 192 168 1222 1812 12345678 2 M 1921681222 1812 10345678 Apply This function is used to configure RADIUS Servers for administrator authentication operation This device supports two RADIUS Servers for redundant applications 61 www vseprofttx cz official dealer CZ SK CENTEL s r o 7 4 4 Port This section is about configurations for ports 7 4 4 1 Port Configuration br ur ou JE o o o JEJE JE JE rd m m mm mn n n n n n n n Port Configuration Name Apply 1 Enable Enable Support full duplex only Current Setting amp Link Status Speed Link Pass th ES Port 1 Port 1 Enable Auto Enable DOWN 8 Port Configuration 2 Port 2 Enable Auto Enable DOWN S Port Statistics 3 Port 3 Enable Auto Enable DOWN 8 DDMI 4 Port 4 Enable Auto Enable DOWN Cg Tools 5 Port 5 Enable Auto Enable DOWN 6 Port 6 Enable Auto Enable DOWN 2 Port 7 Enable Auto Enable DOWN 8 Port 8 Enable Auto Enable DOWN 9 Port 9 Enable Auto Enable DOWN 10 Port 10 Enable Auto Enable DOWN 11 Port 11 Enable Auto Enable DOWN 12 Port 12 Enable Auto Enable DOWN 13 Port 13 Enable Auto Enable DOWN 14 Port 14 Enable Auto Enable DOWN This function is used to configure port settings of the de
40. mand This command is used to show current device IP configuration show ip interface Interface information redirects Default gateway configured for this device show ip interface command will show current device IP configuration For example show ip interface IP address and netmask 192 168 1 12 255 255 255 0 on VLAN 1 show ip redirects command will show current IP gateway setting of the device For example show ip redirects gateway 192 168 1 254 6 show line command This command is used to show current console line configuration 43 www vseprofttx cz official dealer CZ SK CENTEL s r o show line console command is used to show current console line configuration show line console Password threshold open end time Baudrate 9600 Databits 8 Parity 0 0 1 2 3 NONE EVEN ODD MARK SPACE Stopbits 1 7 show log command This command is used to show current system log and system log configuration show log configuration logging configuration cr show log command is used to show current system log content For example show log 5 Sat Jan 01 10 20 31 2011 Level 6 User admin login from console 4 Sat Jan 01 10 17 29 2011 Level 6 User admin login from console 3 Sat Jan 01 10 14 29 2011 Level 6 User admin login from console 21 Sat Jan 01 10 14 23 2011 Level 6 Authentication Failure from console 1 Sat Jan 01 10 10 00 2011 Level 4 System Started Show log configuration command
41. mation log Log records management Management IP filter radius server RADIUS server information running config Information on the running configuration snmp Simple Network Management Protocol statistis sntp Simple Network Time Protocol configuration system System information version System hardware and software versions 1 show aaa authentication login command This command will show the authentication settings for admin of the device when login for management t could be authenticated by local or RADIUS Server or local first RADIUS Server next For example show aaa authentication login Authentication local 2 show calendar command This command will show current system time For example show calendar Current Time 2008 08 29 1 1 27 12 3 show history command This command is used to show the history of input commands show history 0 show 41 www vseprofttx cz official dealer CZ SK CENTEL s r o 1 show history 4 show interface command This command is used to show port information and status show interface counters Interface counters information mgmtport Interface management port information status Interface status information switchport Interface switchport information show interface counters command will show total statistics counters for all ports show interface counters ethernet 1 x command will show statistics counters for Port x x is the port number For example show interface count
42. modem for firmware configuration binary text Configuration File Support both binary and text format 70 www vseprofttx cz official dealer CZ SK CENTEL s r o B Compliances EMI Certification FCC Class A Certification USA Warning This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause interference to radio communications It has been tested and found to comply with the limits for a Class A digital device pursuant to Subpart B of Part 15 of FCC Rules which are designed to provide reasonable protection against such interference when operated in a commercial environment Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures are required to correct the interference CE Mark Declaration of Conformance for EMI and Safety EEC This is to certify that this product complies with ISO IEC Guide 22 and EN45014 It conforms to the following specifications EMC EN55022 2006 CLASS A EN61000 3 2 2006 EN61000 3 3 1995 1 2001 A2 2005 EN55024 1998 A1 2001 A2 2003 IEC61000 4 2 2001 IEC61000 4 3 2006 IEC61000 4 4 2004 1 2006 Corr 2 2007 IEC61000 4 5 2005 IEC61000 4 6 2006 IEC61000 4 8 2001 IEC61000 4 1 1 2004 This product complies with the requirements of the Low Voltage Directive 2006 95 EC and the EMC Directive
43. ode or Multi Mode and Tx Rx is pluged correctly 4 TX port of the pair should be ready for link up if link pass through function is enabled Link pass through function could be disabled to verify the connection of SFP port first After SFP port connection is verified and TX port is link up then enable link pass through function TX port LED is OFF 1 Check the cable connection and link status at both sides of cable The connection of another side of cable should be ready for link up Check the connecting Ethernet port Fast Ethernet port supports 100Mbps only If SFP port will be link up at 1000Mbps change the connecting Ethernet port to Gigabit Ethernet port SFP port of the pair should be ready for link up if link pass through function is enabled Link pass through function could be disabled to verify the connection of TX port first After TX port connection is verified and SFP port is link up then enable link pass through function Traffic is blocked when both SFP and TX LEDs are ON 1 Check the configuration status of the connecting network devices The traffic could be blocked by the configuration status of the connecting network devices e g VLAN setting port disable because of loopback or storm control 67 www vseprofttx cz official dealer CZ SK CENTEL s r o 9 Software Update and Backup This device supports software update and configuration backup update restore functions could be done in two
44. orts in this range For example interface ethernet 1 4 7 and the settings after this command will be applied to Port 4 Port 5 Port 6 and Port 7 Port 4 7 interface ethernet 1 w x y z and 2 are port number All the settings after this command will be applied to those ports For example interface ethernet 1 1 2 4 7 and the settings after this command will be applied to Port 1 Port 2 Port 4 Port 5 Port 6 and Port 7 Port 4 7 Entering interface ethernet 1 5 and its prompt will become configy interface ethernet 1 5 config if Enter at the prompt the sub command list will be shown config if exit Exit from current mode help Show available commands history Show a list of previously run commands logout Disconnect quit Quit commands description Interface specific description end Exit from interface mode interface Enters privileged interface configuration Ipt Enable link Pass through no Negates a command or sets its defaults 34 www vseprofttx cz official dealer CZ SK CENTEL s r o shutdown Shuts down the selected interface speed Configures speed operation 1 exit command This command is used to leave current operation mode Go back to last mode 2 help command This command is used to show all the available commands in this mode 3 history command This command is used to show the history of entering commands 4 logout command This command is u
45. ost name of the device Contact this is the contact information for the device Location this is the location information of the device SNMP Communities Get this is the community string of GET command for SNMP operation GET command is used to read device configuration information Set this is the community string of SET command for SNMP operation SET command is used to set device configuration 57 www vseprofttx cz official dealer CZ SK CENTEL s r o ANS bw wr m o oo o e n fe CIDOB wma n n n n n n n n m m mn 1 alt A Name CL MCSFP 16M Contact 1 00 01 011 Location Community Name Cg SNMP GET public 8 Configuration SET pe 0 amp Cg Security TI HE Tools IP Address Community Name Status pooo Die v poo t S Disstie pooo Disable v O00 public Disable v 000 Disable v Index Username Security Level Authentication Privacy 1 admin noauth v ND5 s DES SNMP IP Trap Manager Trap function will send notice message to SNMP management station when some events happen Up to five SNMP management stations are supported for Trap function The community string and enable disable setting for each trap are set here User Information This is used to configure SNMPv3 administrator settings The default user name is admin The security level and authentication manner could be configured here The
46. peed of the connection The link speed could be 100Mbps or 1000Mbps After the link speed is detected TX port of the pair will be set to the same operation speed 2 Check the link status of SFP port The device will always check the link status of SFP ports If any SFP port is link down the device will force TX port of the pair to link down to pass down the link status if link pass through function is enabled 3 About the link status of TX port The device will also check the link status of TX ports If any TX port is link down the device will force the SFP port of the pair to link down to pass down the link status if link pass through function is enabled The TX port will be forced to the same link speed as SFP port of the pair If the connecting Ethernet device is a gigabit port it will be link as 100Mbps or 1000Mbps depending on the link speed of SFP port If the connecting Ethernet device is a 100Mbps port it will be link as 100Mbps only If SFP port will be link as 1000Mbps the TX port of the pair will not be link up In this case please change the connecting Ethernet device to a gigabit port for link up 13 www vseprofttx cz official dealer CZ SK CENTEL s r o 7 Manage Configure the Device 7 1 Introduction of the management functions This device is a management device An Ethernet port is supported for out band management function from Http Telnet SNMP interfaces Console is supported for local command line settings
47. r some user groups x is the index of the user group More than one protocols can be enabled at the same time e g management 2 protocol http snmp telnet And no management x protocol command is used to disable all remote management protocols for the user group 28 www vseprofttx cz official dealer CZ SK CENTEL s r o 14 no command This command can do the following settings And it depends on the command after it 1 Disable a function For example logging command can enable the logging function and no logging command can disable it 2 Restore a setting to factory default of the device For example ip default gateway 192 168 1 100 will set the IP gateway of the device to 192 168 1 100 and no ip default gateway will put it to factory default setting 192 168 1 254 3 Clear a setting For example hostname abc will set the SNMP host name as abc And no hostname will clear this setting Entering no the sub commands will be shown no aaa AAA Service hostname Sets system s network name ip Global IP configuration sub commands logging Modifies message logging facilities management Specifies management IP filter radius server Configures login to RADIUS server snmp server Modifies SNMP server parameters sntp Simple Network Time Protocol configuration 15 prompt command This command is used to set the prompt word for command line interface For example config prompt AAA AAA config 16
48. rom web SNMP Sat Jan 01 12 09 09 2011 6 Authentication Failure from web Sat Jan 01 11 59 25 2011 6 User admin login from web Secunty Sat Jan 01 11 49 31 2011 6 User admin login from web Eg Pot Sat Jan 01 11 17 24 2011 6 User admin login from console ben Sat Jan 01 10 10 00 2011 4 System Started Tools Sat Jan 01 10 10 00 2011 4 System Started Sat Jan 01 10 10 00 2011 4 System Started Sat Jan 01 10 53 08 2011 3 Upgrade firmware from web Sat Jan 01 10 10 06 2011 5 User admin login from web Sat Jan 01 10 10 00 2011 4 System Started You can view log table content here There could be more than one page You may change the page or go to a page by its operation icons Clicking clear log button will clear the local log table 56 www vseprofttx cz official dealer CZ SK CENTEL s r o 7 4 2 SNMP This function is used to configure SNMP function of the device This device supports SNMP vi v2c and v3 agent function and MIB Il Interface Private MIB CII o ood fe m mn mn mn n n n n n n n n n m n CL MCSFP 16M SNMP Configuration 1 00 01 built at May 5 2011 Object ID 1 3 6 1 4 1 655 80 21 Up Time 0 day 0 hour 7 min 22 sec Version we System Information Object ID this is the SNMP Object ID of the device for SNMP management Up Time this is the power up running time of the device Version this is used to select SNMP agent operation version Name this the h
49. s is a help command and the console will prompt with all available commands 3 history command This command will show the history of entering commands 4 logout command This is a logout command 5 ping command User can use this command to ping another network device to verify the network connection and activity It is similar to the ping command in MS DOS 20 www vseprofttx cz official dealer CZ SK CENTEL s r o Enter ping at the prompt the command syntax will be shown ping Syntax ping n count length t w timeout ip n count Number of echo requests to send length Send buffer size and length is between 64 8148 t Ping the specified host until stopped by lt ESC gt key W Timeout in milliseconds to wait for each reply ip IP address For example ping 192 168 1 80 Esc can be used to break continuous ping operation 6 quit command This command is used to quit the console interface 7 reload command This command is used to reset device t will halt and perform a warm restart Enter reload at the prompt you will be asked to confirm the action reload Are you sure to reset now Y N If y is entered the device will reboot If is entered just leave and no any action will go 8 show command This command is used to show current system information and system configuration Enter show at the prompt the sub command list w
50. s of the device 4 4 Enter exit command to go back to config prompt 4 5 If IP Gateway wil be set enter ip default gateway XXX XXX XXX XXX command to set the IP gateway of the device XXX XXX XXX XXX is the IP address 4 6 Enter exit command to go back to prompt 4 7 Enter show ip interface to check the IP settings 4 8 Enter show ip redirects to check IP gateway setting After IP address configuration done and the management port of the device is connected to network users can start Http connection by entering IP address of the device to the web address line in Web Browser A login screen will be prompted for user name and password The default user name and password is admin admin Then the management homepage will appear 50 www vseprofttx cz official dealer CZ SK CENTEL s r o f i mm n n jn n n n n n n i System Information Main Board Information Firmware Version 1 00 01 built at Jun 2 2011 10 50 54 Mac Address 00 00 00 00 00 88 Number of Ports 16 Left part of the homepage is a function list Users can select one of them for status monitoring or device configuration Upper part of the homepage is the link status of the device Three different colors are used to show different status of ports Link Up Link Down and Port Disable Middle part of homepage is the main operation area for each function The details about management with http
51. s r o Mount the Device on a Rack T 1 Position a bracket that is already attached to the device on one side of the rack 2 Line up the screw holes on the bracket with the screw holes on the side of the rack 3 Use a screwdriver to install the rack screws through the mounting bracket holes into the rack 4 Repeat Step 1 3 to attach another bracket that is already attached to the device on another side of the rack 8 www vseprofttx cz official dealer CZ SK CENTEL s r o 3 Configure Network Connection 3 1 Connecting to the Device Connection Guidelines For 100BaseTX connection Category 5 twisted pair Ethernet cable For 1000BaseTX connection Category 5e or 6 twisted pair Ethernet cable For TX cable connection always limit the cable distance to 100 meters 328 ft as defined by IEEE specification For 100BaseFX 1000BaseSX 1000BaseLX connections you can connect long distance fiber optic cable to the device Because this device supports Auto MDI MDI X detection on each TX port you can use normal straight through cable for both workstation connection and hub switch cascading Fiber Optic Cable 10 KM away Cat 5e Twisted Pair Cable 100 meters max 9 www vseprofttx cz official dealer CZ SK CENTEL s r o 3 2 Application The device can be used to convert different Ethernet media e g fiber optic cable to copper cable It depends on the SFP module that plugged on SFP slot Because fiber optic
52. sed to logout from console interface 5 quit command This command is used to quit from console interface It has the same function as logout 6 description command This command is used to assign a description string for the port s description xxx command will assign a description string for the port s xxx is the string no description command will clear the description string 7 end command This command is used to exit from interface mode config if end config 8 interface command This command is used to change the interface port s or interface 35 www vseprofttx cz official dealer CZ SK CENTEL s r o VLAN for next setup commands config if interface ethernet Ethernet port vlan Virtual LAN interface For example config interface ethernet 1 5 will set current setup interface to Port 5 and all the commands will be applied to Port 5 config if interface ethernet 1 6 7 will change current setup interface to Port 6 7 and all the commands will be applied to Port 6 7 If vlan sub command is used current setup interface will be changed to some VLAN For example config if interface vlan 100 will change current setup interface to VLAN 100 and all next commands will be applied to VLAN 100 The description of commands in interface configuring mode is put in Section 7 2 4 Interface Configuring Commands Please refer to the section for the details 9 Ipt command This command can be used to
53. send event record to the syslog server About log function configuration System Log Status This can enable disable system logging function Log Level 0 7 Log levels 0 7 are defined as below And events with lower log level than this number will be recorded Level Name Description 0 Emergency System is unusable 1 Alert Action must be taken immediately 2 Critical Critical conditions 3 Error Error conditions 4 Warning Warning conditions 5 Notice Normal but significant condition 6 Informational Informational messages 7 Debug Debug level messages Remote Log This can enable disable remote syslog function Remote Log Server IP This is the syslog server IP for remote logging Up to five syslog servers is supported Event logs will be sent to those 55 www vseprofttx cz official dealer CZ SK CENTEL s r o Syslog servers at the same time Log Table wp nw n o o e em J SHA SESE Logs Table Eg System System Information eve Contguraton Sat Jan 01 10 11 27 2011 6 User admin login from console Sat Jan 01 10 10 00 2011 4 System Started 9 Time Contiguration Sat Jan 01 10 12 11 2011 3 Upgrade firmware from web 33 Log Sat Jan 01 10 10 00 2011 4 System Started Sat Jan 01 12 44 24 2011 6 User admin login from web Configuration Sat Jan 01 12 11 11 2011 6 User admin login from web Log Table Sat Jan 01 12 11 05 2011 6 Authenbcation Failure f
54. t Specifies management IP filter no Negates a command or sets its defaults prompt Sets system s prompt radius server Configures login to RADIUS server snmp server Modifies SNMP server parameters sntp Simple Network Time Protocol configuration username Establishes user name authentication 1 exit command This command is used to leave current operation mode Go back to last mode 2 help command This command is used to show all the available commands in this 24 www vseprofttx cz official dealer CZ SK CENTEL s r o mode 3 history command This command is used to show the history of entering commands 4 logout command This command is used to logout from console interface 5 quit command This command is used to quit from console interface It has the same function as logout 6 aaa command This command is used to set the authentication manner for administrator of the device when login by http s telnet for management It could be authenticated by local device or by RADIUS Server Here is the command for the setting aaa authentication login local command will set the authentication manner for administrator by local device when login by http s telnet for management aaa authentication login radius command will set the authentication manner for administrator by RADIUS Server when login by http s telnet for management aaa authentication login local radius command will set the authentication manner for administrator by loc
55. the refresh interval And you can click Refresh to refresh the counters immediatelly Reset Counters Click Reset Statistics can reset all counters to O 63 www vseprofttx cz official dealer CZ SK CENTEL s r o 7 4 4 3 DDMI bur n ue m o w mn mm n mn n n n n n n n n n i Digital Diagnostics Monitoring Interface Destination Port 1 CL MCSFP 16M 011 1 00 01 built at Jun 2 2 10 50 54 Serial Info Table Status N A Vendor PartNo SerialNo Revision DateCode 19 Port Configuration Transceiver N A 8 Port Statistics DDMI Ddm Info Table EC Tools Type AlarmMax AlarmMin WarnMax WarnMin Current sa Too N A 0 0 0 0 0 0 0 0 0 0 N A 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Refresh SFP Module DDMI information status can be monitored here Select a port to get the SFP Module DDMI information status Serial Info Table This table will show information about the SFP module like vendor part number serial number revision date code and transceiver mode Ddm Info Table This table will show current operating voltage temperature transmit bias transmit power and receive power of SFP module And the maximum and minimum limit will be shown in the table If the limit is met the device will send a SNMP trap for it Refresh You can click Refresh to refresh the values 64 www vseprofttx cz official dealer CZ SK CENTEL s r o 7
56. tx cz official dealer CZ SK CENTEL s r o 7 2 Settings with Console Connection 7 2 1 Basic of the Console Interface lt lt Enter Console Interface gt gt Follow the steps to complete the console hardware connection first 1 Connect from console port of the device to COM port of PC with the console cable 2 Start the terminal program of Windows Create a new connection and select COM port of PC used for the console Set the configuration of the terminal as 9600 8 N 1 You can find the terminal program in Start gt Programs gt Accessory Programs gt Communication gt Terminal If you cannot find it please install it from your Windows Installation Disk Please refer to your Windows user manual for the installation 3 Power on the device If everything is correct the booting message will appear in the terminal program when the device is powered on It will stop at the following screen after some initializing messages Bootloader Ver 1 05 00 256K Config at 13 50 52 Sep 8 2009 RAM 0x00000000 0x00800000 0x0000cc78 0x007f3000 available FLASH 0x05800000 0x05a00000 32 blocks of 0x00010000 bytes each gt enter C to abort booting within 3 seconds Start to run system initialization task System Configuration Company Name Model Name CL MCSFP 16M MAC Address 00 00 00 00 00 88 Firmware version 1 00 01 built at Jun 22011 10 50 54 Username lt lt User Modes gt gt There are t
57. vice Port Setting It is for modifying the settings of port do it Follow the steps to Select the port that you want to modify in first Fill the name of the port Admin is for port enable disable setup Speed could be auto 1000M or 100M Link Pass through is for link pass through function enable disable Click Apply after any modification Current Setting amp Link Status It is current setting and link status of ports Name The name of the port Admin enable disable status of the port Speed speed setting of the port Link Pass through link pass through function enable disable status TX Link TX port link status SFP Link SFP port link status 62 www vseprofttx cz official dealer CZ SK CENTEL s r o 7 4 4 2 Port Statistics Lu n a o o o o o m w n mn mn mn n n n n n n n n n n n Port Statistics Destination Port Refresh Interval 5 60 secs CJ System Tx Port Counter Statistics x Receive Good Packet 0 Eg SNMP z Receive CRC Error Packet 0 Security SFP Port Counter Statistics Receive Good Packet 0 8 Port Configuration Receive CRC Error Packet 0 8 Port Statistics Refresh Reset Statistics amp Domi BRE Tools Port statistics counters could be read here Select a port to get its counters Refresh The counters will be refreshed automatically You can modify
58. vseprofttx cz official dealer CZ SK CENTEL s r o 1 General Basic Commands These are basic commands after login Users can show device configueartion status ping network device reboot device The prompt is xxx for admin user and xxx gt for guest user 2 Configure Mode Commands With configure command user can enter Configure Mode Commands in Configuring Mode are for general device settings And its prompt is config 3 Interface Configuring Commands for Port Group If the settings are for ports it is done with interface ethernet 1 x command in configure mode And the prompt will become config if For example interface ethernet 1 5 is for settings on Port 5 19 www vseprofttx cz official dealer CZ SK CENTEL s r o 7 2 2 General Basic Commands When admin admin is used for username password the console will enter administrator mode Enter command list will be shown 7 exit Exit from current mode help Show available commands history Show a list of previously run commands logout Disconnect ping Sends ICMP echo packets to other network nodes quit Quit commands reload Halts and performs a warm restart show Shows information calendar Data and time information configure Enter configuration mode copy Copies from one file to another 1 exit command This command is used to leave current operation mode It will do logout at this basic command interface 2 help command Thi
59. wo user modes for the device one is administrator mode privileged mode another is guest mode normal mode 16 www vseprofttx cz official dealer CZ SK CENTEL s r o administrator mode The default user name and password is admin admin After login the device a prompt will be shown Because this device supports command line for console interface you can press to check the command list first With command you can find the command list as follow 7 exit Exit from current mode help Show available commands history Show a list of previously run commands logout Disconnect ping Sends ICMP echo packets to other network nodes quit Quit commands reload Halts and performs a warm restart show Shows information calendar Data and time information configure Enter configuration mode copy Copies from one file to another These are the basic system commands for the device For system configuring configure command can enter the configure mode And the prompt will become configure xxxx config In the configure mode the general configuration of the device can be done And exit command can leave this mode If settings for port interface command is used And the prompt will become interface ethernet 1 5 xxxx config if ethernet 1 5 means Ethernet interface 1 port 5 And exit command can leave this mode interface command has another sub comm
60. ww vseprofttx cz official dealer CZ SK CENTEL s r o interface ethernet 1 1 interface ethernet 1 2 interface ethernet 1 3 interface ethernet 1 4 interface ethernet 1 5 interface ethernet 1 6 interface ethernet 1 7 interface ethernet 1 8 interface ethernet 1 9 interface ethernet 1 10 interface ethernet 1 11 interface ethernet 1 12 interface ethernet 1 13 interface ethernet 1 14 interface ethernet 1 15 interface ethernet 1 16 linterface vlan 1 ip address 192 168 1 1 255 255 255 0 46 www vseprofttx cz official dealer CZ SK CENTEL s r o lend 11 show snmp command This command is used to show SNMP configuration of the device For example show snmp SNMP Configuration Object ID 1 3 6 1 4 1 655 80 21 System up Time 9248 seconds System Name Location Contact name Get Community public Set Community private Trap Community ID Status Community IP Address 1 Disabled public 0 0 0 0 2 Disabled public 0 0 0 0 3 Disabled public 0 0 0 0 4 Disabled public 0 0 0 0 5 Disabled public 0 0 0 0 Version V3V2cV1 Username admin SnmpSecurityLevel noauth Authentication MD5 Privacy Des 12 show sntp command This command is used to show system time settings of the device D S T means Daylight Saving Time For example show sntp Get Time By Manually Time