1. D E Hokanson Inc 12840 NE 21st Place Bellevue WA 98005 USA Telephone 1 800 999 8251 or 425 882 1689 Fax 425 881 1636 Web site www hokanson cc E mail info deh inc com About Hokanson Since 1973 D E Hokanson Inc has provided reliable noninvasive vascular diagnostic instruments of the highest quality to the medical community We manufacture our instruments with a commitment to excellence in research materials and workmanship You our customers are a key factor in our research and development process We invite you to contact us with feedback about your Hokanson products Following this tradition we continue to update and add to our product line This catalog gives a general description of each of our products For more specific information or for the name of your local Hokanson representative please contact Hokanson directly or visit our website at www hokanson cc We look forward to working with you in providing convenient effective health care throughout the world Kyra Hokanson Gray President Quality at an Affordable Price Exceptional value Our goal with every instrument is to make it easy to use accurate and reliable all at a reasonable price Your investment in Hokanson will serve you well and keep its value Ease of operation Self explanatory buttons control the most important functions of each of our instruments We design every instrument to ensure that the controls are logical visibl
2. Hokanson STORE Rechargeable battery makes it ready at all times DALE RF DATA LUNE 1 800 999 8251 fax 425 881 1636 www hokanson cc 10 MD35 Cuffs Exceptional durability and fit specitic cuffs based on your needs Our cuffs are of the distinctive Hokanson blue with our logo on them they offer exceptional AA ere set of cuffs is offered in the CVS4 product line You can purchase the optional Segmental Pressure Package or purchase quality durability and fit The following types of cuffs are applicable for tests performed by the MD35 All of these cuffs have a female Luer fitting for inflation and will work with the DS400 or TD312 with or without the MV10 Cuff selector ADINISDA The Straight Segmental Cuffs are used in many exams Choose cuff sizes according to the limb circumference Cuffs should be 20 wider than the diameter of the limb where you will be applying the cuff The wrong sized cuff will give an incorrect pressure After removing the bladders these cuffs can be washed in a washing machine on gentle cycle with soap Line dry and when completely dry insert the bladder Bladders and covers are replaceable and can be purchased from Hokanson Straight Segmental Cuffs Model Overall Cuff Size Cuff Application SC10 11 x 85 cm Upper arm and lower leg for segmental pressure measurements and pulse volume recordings four cuff method SC I2 13 x 85 cm Upper arm and upper leg for segmental pre
3. Maximum Venous Outflow v Vascular Venous Reflux v v Vascular Venous Insufficiency with Duplex Scanner Phlebology Venous Reflux with Duplex Scanner Phlebology Ankle Brachial Index Primary Care Toe Brachial Index Primary Care Toe Pressures Primary Care Post Exercise Pressures with Automatic ABI Calculation Primary Care Pulses Hospital Systolic BP Hospital Post Revascularization Pulse Check Hospital Sees ee m e va nA aa a ae aes Les ee ay aS ae aa ae fa Po a Ss aa ae a ae ee a E a Po po pelea a Sy poe CO E E SS ae pe continues next page Hokanson 1 Our Tests amp Applications Tests and Applications Doppler PPG Pneumo Strain Specialty Gauge Arterial Inflow Venous Occlusion Plethysmography Endothelial Function Research Arienia Presses ualia Wedo Arela a ec continued from previous page In the chart below all tests where a Doppler could be used to perform the test are listed first followed by all tests that can use photo plethysmography then all that can use pneumo plethysmography and last strain gauge plethysmography Instruments are listed from simplest to most complex in the instrument fields Tests and Applications Instrument Doppler PPG Pneumo Strain Specialty Gauge Upper amp Lower Extremity Arterial amp MD6 System v Vascular Venous Doppler MD35 CVS4 Upper amp Lower Extremity Spectral CVS4 v Vascular Doppler Ankle Brachial Index Portable ABI K
4. you can choose which tests to include in the hard copy Tracking ABI s post exercise pressures and other vascular stud ies over time can be accomplished via graphs When combined with the MD35 and the TD312 cuff inflator software remote control the clinician can inflate deflate cuffs as well as enter data and navigate the software remotely This software is also compatible with legacy devices from Hokanson For more information sample reports and other supporting documents please go to our website www hokanson cc TD312 Cuff Inflator and Software Remote Control The TD312 is ideal for inflating cuffs for the MD35 The thumb wheel is pushed forward away from you to in flate and pulled towards you to deflate with no manual pumping making cuff inflation easy The rechargeable battery makes this automated cuff inflator ready at all times just recharge overnight when the battery display says the charge is 11 Volts or under A fully charged battery pack reads 14 Volts on the display When used with the NIVP3 Arterial and Venous Software it provides a handy software remote control and facilitates the pressures and waveform data entry by pushing the Store button The computer interface is available with ei ther a wireless RF radio frequency US only or a wired connection Data Link It can inflate any size cuff and remember the pressure for you The metal male Luer fitting fits all cuffs with a female Luer fitting and the MV10 Cuff Selector
5. 9 cm Middle toes and fingers UDC2 5 2 5 x9 cm Large fingers and middle toes UPC2 5 2 5 x 12 cm Large toe or penis UPC3 3 3 3 x 12 cm Very large toe or penis DC1 6 1 6 x 9 cm Small toes and fingers DC1 9 1 9 x9 cm Middle toes and fingers DC2 5 2 5 x 9 cm Large fingers and middle toes PC2 5 2 5 x 12 cm Large toe or penis PC3 0 3 3 x 12 cm Very large toe or penis For more information and supporting documents please go to our website www hokanson cc Thermal chart paper TCPG60 case of 60 rolls and TCPG3 box of 3 rolls are the two thermal chart paper options for the MD35 chart recorder This thermal chart paper comes with the grid pre printed on it For more information and supporting documents please go to our website www hokanson cc ow En Lj i RJ Bd aa F iza 1 800 999 8251 fax 425 881 1636 www hokanson cc 12 RD2 Rapid Cuff Deflator The RD2 plunger rapidly exhausts the air from a vascular cuff for venous outflow measurements it can be used with the contoured thigh cuffs and rapid version straight cuffs It works well with either the DS400 or the TD312 inflator Pushing in the plunger quickly deflates the attached inflated cuff The RD2 uses the same unique connection system as the E20 Rapid Cuff Inflator for maximum exhaust rate For more information and supporting documents please go to our website www hokanson cc Pushing in the plunger quickly deflates
6. Penile cuffs are made to fit correctly and securely They are used for taking measurements with photo and pneumo plethysmographs as well as strain gauges The durable cuffs include both latex and latex free polyurethane versions in the same sizes These cuffs have one inlet tube with a plastic Luer fitting for inflation with either the TD312 or DS400 cuff inflators with or without the MV10 Cuff Selector With an adaptor Digit and Penile cuffs can also be inflated by the E20 AG101 for controlled inflation deflation Durable latex free polyurethane cuffs Model UDC1 6 UDC1 9 UDC2 5 UPC2 5 UPC3 3 DC1 6 DC1 9 DC2 5 PCZ am PC3 3 Disposable Digit or Penile Cuffs Disposable cuffs are designed for peace of mind for you and your patients These disposable cuffs are packaged and meant to be used for one patient they can be used more than once on a patient and then disposed properly They are made of PVC poly vinyl chloride and have a white latex tube with a female Luer fitting for connection with the TD312 or DS400 cuff inflator They are packaged individu ally and come in packages of 10 25 or 100 Model DP2 0 DP2 5 Overall Cuff Size 1 6 x9 cm 1 9x9cm 2 5 x9 cm 2 5 x 12 cm 3 3 x 12 cm 1 6 x9 cm 1 9 x 9 cm 2 5 x9 cm 2 5 x 12 cm 3 3 x 12 cm Overall Cuff Size 2 1 x 12 1 cm 3 0 x 12 1 cm Cuff Application Small toes and fingers Middle toes and fingers Large f
7. Selector T he TD312 is ideal for busy practices or large screening clinics The thumb wheel is pushed forward E E G For taking segmental pressures during deflation of the cuff when the Doppler signal returns at each site you a E push the Store button to save the pressure reading up to 12 pressures can be stored in the memory You can recall the stored pressures when in memory mode as well as calculate the pressure indices such as the ABI T and TBI For more information sample reports and other supporting documents please go to our website www hokanson cc is Handheld Dopplers MD6 Doppler At 9 ounces 250 grams the MD6 is a compact convenient pocket Doppler The high quality audio signal uses Dynamic Noise Reduction DNR and is easy to hear even in a noisy room The patented red and green LEDs on the end of the Doppler probe show you visually when you are on the artery at the best place for a signal it flashes a bright green LED light which is brightest when you are on the sweet spot Green means flow towards the probe or arterial blood When the probe is over a vein the LED flashes red to indicate flow away from the probe To get an audio stereo effect for distinguishing blood flow purchasing optional stereo earphones allows you to hear flow towards the probe in the left ear and flow away from the probe in the right ear The controls for Doppler on off and chart recorder start stop are on the probe The Dopp
8. be recorded when the chart paper runs Some of our Dopplers also provide an aural indication of flow direction through stereo headphones flow toward the probe is heard in the left ear and flow away from the probe in the right ear Dynamic Noise Reduction DNR is a trademark of National Semiconductor for their patented noise reduction circuitry used in hi fi audio applications to reduce back ground hiss We were the first to license this technology for use in a Doppler instrument As a result our instruments eliminate hiss without using common filters which would limit high fidelity response Accurate diagnosis often depends on clear high frequency audible signals 1 800 999 8251 fax 425 881 1636 www hokanson cc 34 Plethysmograph To evaluate bloodflow A plethysmograph is an instrument used to determine and register variations in the size of an organ or limb Evaluation of bloodflow and diagnosis of vascular disease can be performed with several types of plethysmographs each has its own advantages We manufacture three types Photo Plethysmograph PPG This instrument uses infrared sensors to detect skin color changes that occur with each heartbeat The output of the photo plethysmograph is a waveform showing volume changes in the measurement area This instrument is typically used in the detection of bloodflow and the measurement of blood pressure A limitation is that variations in skin color and the method of application preclude
9. detects peripheral bloodflow in the arm and ankle The patented red and green LEDs on the end of the Doppler probe show you visually when the transducer is positioned over the artery at the best place for a signal it flashes a bright green LED light which is at its maximum when you are on the sweet spot e MD6VR Chart Recorder Prints real time Doppler waveforms from the MD6 used for documentation e Four straight segmental blood pressure cuffs One cuff for each arm and one for each ankle e DS400 Aneroid sphygmomanometer Ambidextrous rugged cuff inflator allows easily controlled cuff bleed rate For more information sample reports and other supporting documents please go to our website www hokanson cc 1 800 999 8251 fax 425 881 1636 www hokanson cc 20 The TBI Package Toe Pressure Kit The TBI Package adds the toe pressure to the Portable ABI Kit so patients with abnormally high ABI s typically those greater than 1 3 can be examined properly Calcification of the arterial blood vessels in the legs cause an abnor mally high ABI and they are not considered accurate For these patients the Toe Brachial Index TBI gives an accurate assessment of the presence of PAD by using photo plethysmography to detect pulses and systolic pressures on toes It is easy to perform and necessary for evaluation of patients with calcified vessels It uses the Chart Recorder from the Portable ABI Kit It can fit into the carrying case
10. for researchers who want a completely automated system with everything needed to perform the most advanced strain gauge plethysmography testing available today Using built in protocols you control the variables and can easily replicate the test with multiple patients You can create your own standard protocols easily and save them for future use The Al is the solution for simplifying and automating bilateral limb bloodflow studies Once the protocols are set to your specifications and the patient prepared the Al does the rest for you An ECG input is used to synchronize the venous occlusion cuff with the patient s heart beat to improve the consistency of the measurements An invasive arterial line can be used to calculate arterial resistance All testing is bilateral and some researchers use one limb as the control for the experi ment There is a wide range of test protocol options all in the researcher s control All test data is stored for you to review and the software assists you with the inflow rate measurements and data analysis Once data is acquired it is stored in a database for easy recall edit and report print outs The Al comes with standard protocols for measuring arterial inflow in one or two limbs simultaneously including automatic reactive hyperemia testing You can control the inflation times and durations and the software controls the instruments and records the measurements automatically based on your settings Th
11. for the vascular community and our distinctive Hokanson blue cuffs have become the standard for peripheral vascular testing for both clinical and research use They offer exceptional quality durability and fit We have a variety of sizes and types from straight segmental for arms and legs to digit penile cuffs with and without latex All Hokanson cuffs have a female Luer fitting for use with the TD312 or DS400 cuff inflators with or without the MV10 Cuff Selector Additionally Hokanson can manufacture custom cuffs for more information please call or e mail us with your needs When cuffs are washed the bladders should be removed first The bladders should not be replaced until the cuffs are completely dry The vascular cuff blue covers can be washed on gentle cycle in a washing machine with mild soap rinse well and then line dried NEVER AUTOCLAVE A CUFF as this will destroy it Straight Segmental Cuffs All segmental cuffs are latex free and have a replaceable polyurethane bladder and washable blue nylon cover Fit is important so measure each patient s limb in relationship to the cuff The cuff width should be 20 larger than the limb diameter to compress all of the soft tissue evenly and completely and to provide an accurate blood pressure measurement Always put the cuffs on straight and snuggly but not tight Model Overall Cuff Size Cuff Application SC10 11 x 85 cm Upper arm and lower leg for segmental pressure measurements and pu
12. hokanson cc TCPIO ADP 10 No more taping or pasting Adheres so well it cannot be removed 92 22 p uer gi 1 800 999 8251 fax 425 881 1636 www hokanson cc 16 Dopplers To find the hardest pulse MD6 Doppler Feil om d E amp F atete s F Paratane anas eleletieists iiu At 9 ounces 250 grams the MD6 is a compact convenient pocket Doppler The high quality audio signal uses Dynamic Noise Reduction DNR and is easy to hear even in a noisy room The patented red and green LEDs on the end of the Doppler probe show you visually when you are on the artery at the best place for a signal it flashes a bright green LED light which is brightest when you are on the sweet spot Green means flow towards the probe or arterial blood When the probe is over a vein the LED flashes red to indicate flow away from the probe To get an audio stereo effect for distinguishing blood flow purchasing optional stereo earphones allows you to hear flow towards the probe in the left ear and flow away from the probe in the right ear ADINISDA The controls for Doppler on off and chart recorder start stop are on the probe The Doppler uses rechargeable NiCad batteries and is charged separately from the chart recorder When inserted on the in put jack of the MD6VR chart recorder the waveforms from the Doppler can be recorded MD6 Pocket Doppler with Detachable Transducer
13. volume calibration Strain Gauge Plethysmograph SPG A thin rubber tube filled with Mercury or Indium Gallium is placed around the limb or digit of interest As the volume of the limb changes with each heartbeat the tube is stretched and the electrical resistance increases The measurement is processed and sent as analog information to the display or chart recorder Advantages of our strain gauge plethysmographs are that they are easily and accurately calibrated in situ and can be used in a wide variety of applications Common uses of this instrument include measuring arterial bloodflow into the limbs and digits sometimes called venous occlusion plethysmography venous capacitance maximum venous outflow to detect deep venous thrombosis in the legs and blood pressure measurements in the extremities Pneumo Plethysmograph This plethysmograph detects changes in limb or digit volume from the pressure changes in a sensing cuff This cuff is placed around the limb or digit of interest inflated to a low pressure and sealed off from the inflation device Any change in volume under the cuff is reflected by a pressure change within the cuff This is shown on a display or chart recorder The pneumo plethysmograph is generally used for evaluating waveform shapes and relative amplitude changes It can be calibrated by adding or subtracting a known volume of air to the system and observing the corresponding output changes Advantages of pneumo ple
14. 1636 www hokanson cc
15. R has two options for thermal chart paper One option is the adhesive backed strip paper the ADP10 that allows you to just print remove the backing then adhere it to the patient record with no more taping or pasting and it adheres so well that it cannot be removed The MD35 uses the TCPG60 and TCPG3 thermal chart paper with a preprinted grid The MD6VR and legacy MD6R uses the TCP10 and the ADP10 thermal chart paper The TCP10 and ADP10 do not have a preprinted grid aN AN AAW AA Piakin Piesiniai 92 22 p Uer gi E F 32 Coupling Gel GEL60 60 gram tubes are sold in a package of 12 tubes Coupling gel removes the air between the transducer and the patient s skin air is a poor transmitter of sound waves The gel also aids in the propagation of the sound waves Positioning Aids e Useful for holding patients in positions while performing strain gauge plethysmography The active portion of the strain gauges must only be in contact with the limb to be measured These blocks are made from dense foam and can be easily cleansed and withstand years of use e Two choices PAK 8 which includes two of each shape shown here PAK 5 includes two of each wedge size and one U shaped block 33 SJJND 9 S MOSS DY Doppler For accurate blood pressure All Hokanson vascular Dopplers are bidirectional using a variety of methods to show the direction of flow oppler bloodflow detectors have b
16. This twin to the MD6 Doppler has a detachable cable that is 6 feet 1 8 meters long The controls and re chargeable battery are identi cal to the MD6 Doppler It can also be used with the MD6VR chart recorder for printing waveforms Handheld or pocket Dopplers the MD6 and the MD6 with Detachable Transducer Dopplers are ideal for locating difficult to find pulses or checking post operative pulses on vascular stents or revascularized sites For more information sample reports and other supporting documents please go to our website www hokanson cc Hokanson 17 Rapid Cuff Inflation No need for a second person to do the compression reducing costs Hokansor nee ee ee mas Ti Aan e Try il m miT Hits i Waa il mprove your duplex scanning for Venous Reflux or Venous Insufficiency with the Rapid Cuff Inflation System Get reproducible results and catch the reflux missed when using either Valsalva or hand augmentation The Hokanson E20 eliminates squatting to squeeze the patient s leg compressing all of the soft tissue holding it for precisely the correct amount of time and rapidly releasing the pressure while you scan the leg for venous reflux There is no need for a second person to do the compression reducing the expense of performing this test The E20 inflates any cuff in 0 3 sec holds the pressure indefinitely or for whatever time your protocol needs and then instanta neously deflates the cuff It works ever
17. VS4 spectral Doppler ity sounds are saved so that you can review both waveforms as well as the sounds an excellent Doppler training tool Repre sentative normal waveforms are presented for both viewing and listening comparison For more information sample reports and other supporting documents please go to our website www hokanson cc 1 800 999 8251 fax 425 881 1636 www hokanson cc 6 The DICOM Extension ADINISDA The physician can see both physiological and duplex information for the same patient on the same workstation r ae E _ rT POSTERIOR THLAL ARTERY I VEINS The DICOM Extension shares data with a PACS system and creates one record viewable on all DICOM workstations additionally the in formation viewed on the screen can be printed The physician can see both physiological and duplex information for the same patient on the same workstation The NIVP3 data is available for viewing including playback of Spectral Doppler recordings with sound if DICOM workstation is sound enabled This application facilitates the sharing of the physiological peripheral vascular data including waveforms with another system or application that is also DICOM compatible The WorkList Server function in NIVP3 allows you to populate the the patient demographics from the PACS system parsing it and displaying it in the correct fields in NIVP3 This eliminates the hassle of dupli cate data entry with the subsequent possib
18. e Al includes e Two strain gauge plethysmographs e Two cuff inflators for inflation of four cuffs to two separate pressures e One ECG amplifier for timing e One invasive arterial pressure transducer e One auxiliary analog input for measurement of an extra parameter Features that simplify testing e Two channels of calibrated strain gauge plethysmography to measure two limbs simultaneously e R Wave trigger An ECG amplifier detects the patient s heartbeat and the Al inflates the cuffs at the selected point in the heart cycle The resulting inflow measurements are easier and more repeatable e All instrument controls are on the computer screen making it easy to adjust cuff pressures balance the plethysmographs pause and restart measurements and add test comments to the data For more information sample reports and other supporting documents please go to our website www hokanson cc 1 800 999 8251 fax 425 881 1636 www hokanson cc 24 EC6 Strain Gauge and Photo Plethysmograph EC6 PLETHYSMOGIAPH The EC6 provides researchers with the ability to build to suit the instrumentation they need for using either strain gauge or photo plethysmography for arterial inflow venous testing and a wide variety of measurement applications This is the lowest cost strain gauge m0 2 plethysmograph with in situ electrical calibration this concept was invented by Hokanson and is unique It has become well accepted and is an i
19. e and easy to handle Outstanding quality Our quality control program of mechanical and thermal shock testing for all Hokanson instruments helps to prevent many instrument failures and allows us to confidently offer a full five year warranty the longest in the industry Accurate results Hokanson instruments utilize the highest quality components Each instrument is thoroughly tested for function and accuracy A history of reliability Health care professionals have depended on Hokanson instruments since 1973 Today our instruments are at work in over 35 nations Hokanson is ISO 13485 certified All our products carry the European CE mark Our Catalog How to use this catalog okanson became a company to meet the needs of the vascular community of researchers and clinicians and now has embraced the venous and primary care practitioners Our catalog tailors the instruments to your professional specialty Vascular Phlebology Primary Care Hospital or Research For ease of use we have color coded our products to your specialty and reference them using tabs on right hand pages At the end of the catalog is a display of all of our cuffs by type and some accessories Tests and applications If you are more comfortable thinking in terms of the tests you perform we have provided a matrix below that links each test to the appropri ate instrument also grouped by specialty For sample reports research papers and brochures on all
20. e customer requires a rental instrument to continue lab operations during equipment repair a loaner will be provided free of charge but air freight charges will be the responsibility of the customer 3 After the warranty period if the customer requires a rental instrument to continue lab operations during equipment repair standard charges are 10 of the instrument s value per month plus all air freight charges Minimum rental is one month Terms Payment terms are net 30 days on approval of credit Hokanson customers can also pay for orders with Visa MasterCard American Express prepayment check wire transfer or orders can be shipped C O D in the U S Past due bills will have 1 5 per month added All prices quoted are F O B Bellevue Washington U S A Items must be returned within 30 days of delivery for credit and will be subject to a 10 restocking fee Please notify Hokanson prior to returning any items for repair or replacement Minimum order is 30 00 1 800 999 8251 fax 425 881 1636 www hokanson cc 36 Vascular Instruments Vascular Accessories Education Hokanson 689 e 425 882 1 USA www hokanson cc How to Perform an ABI Peripheral Arterial Disease A complete line of advanced instruments and educational tools for the vascular community of researchers clinicians venous and primary care practitioners 12840 NE 21st Place Bellevue WA 98005 USA 425 882 1689 or 1 800 999 8251 fax 425 881
21. een used in medicine since their invention in Japan by Satomura in 1948 Innovations in Dop pler technology have resulted in easily portable instruments capable of sensing the direction as well as the velocity and location of bloodflow Doppler output is always an audio signal with a pitch proportional to the velocity of the bloodflow and loudness D proportional to the amount of blood Additional outputs include quadrature audio for spectral analysis and analog signals for recording hard copy Dopplers are useful in the measurement of systolic blood pressure determining the patency of arterial grafts tracing individual arteries and veins and detecting fetal heartbeats Direction Sensing Vascular Dopplers with direction sensing capability are typically called bidirectional Bidirectional Dopplers allow you to distinguish between arterial and venous signals based on flow direction and to identify reverse flow in the arteries All Hokanson vascular Dopplers are bidirectional and use a variety of methods to show the direction of flow One direction indicator found in many of our Dopplers is the patented use of red and green LED lights in the probe tip The red lights illuminate to indicate flow away from the probe and the green lights indicate flow toward the probe Other flow direction indicators in Hokanson Dopplers are a bar graph display and printed strip chart The bar graph display shows the level and direction of the flow signal that will
22. enous reflux or insufficiency tests as well as for arterial inflow System These cuffs are made for use with the E20 AG101 or RD2 Rapid Cuff Deflator and do not come with any Luer fittings Model Overall Cuff Size Cuff Application SC10D 11 x 85 cm Upper arm and lower leg for plethysmography and venous reflux measurements SC12D Upper arm and lower leg for plethysmography and venous reflux measurements Fitted with D version tubing All new Hokanson cuffs come with durable polyurethane air bladders Replacement bladders can also be purchased separately for your straight contoured and rapid version cuffs Replacement Bladders Replacement bladders add to the longevity of your cuffs Bladders characteristically do not last as long as the covers so you can purchase replacement bladders for those covers Model Overall Bladder Size Bladder Application SC1ORB 10x 41 cm SC10 Straight Segmental Cuff SC12RB 12 x 41 cm SC12 Straight Segmental Cuff SC12LRB 12 x 56 cm SC12L Long Straight Segmental Cuff SC5RB 5 x 41 cm SC5 Tourniquet Cuff TMC7RB 6 5 x 23 cm TMC7 Transmetatarsal Cuff CCI7RB 17 x 65 cm CC17 Contoured Thigh Cuff CC22RB 22 x 69 5 cm CC22 Contoured Thigh Cuff SC1ODRB 10x 41 cm SC10D Rapid Version Straight Cuff SC12DRB 12x 41 cm SC12D Rapid Version Straight Cuff 1 800 999 8251 fax 425 881 1636 www hokanson cc 30 Digit and Penile Cuffs Digit and
23. ets Thermal Chart Paper Ultrasonic Coupling Gel Positioning Aids Doppler Plethysmographs Hokanson Policies CVS4 Everything you need automated and computerized system for the vascular com munity Everything you need to perform physiological studies using Doppler photo plethysmography or pneumo plethysmogra phy comes with this system Included with your purchase is one day of on site set up and instrument training T he CVS4 is a Complete Physiological Peripheral Vascular The CVS4 for noninvasive peripheral vascular testing provides e Exceptional value e Reliable affordable technology e Ease of operation e Outstanding quality e Accurate results CVS4 components e Continuous Wave Doppler spectra and zero crossing Doppler with bifocal lens for deep amp superficial vessels with one transducer e Automatic cuff inflator and software remote control TD312 e Cuff selector MV10 e Complete set of cuffs for performing segmental pressures and PVR s e Custom cart e Flat panel monitor mini desktop computer Windows and HP Desk jet color printer CVS4 computerized reports e Stores patient information waveforms and pressures e Printed color reports for all tests with a feature that prints only the tests you want e Includes multiple visit graphs for follow up patients e The DICOM Extension is available as an add on to interface with your PACS system Spectral analysis is included with the C
24. for easy transport For more information and sample reports and other supporting documents please go to our website www hokanson cc aipy Aipwilid Excellent for the needs of diabetic patients Toe Pressures are an excellent peripheral arterial check for diabetic patients especially those with wounds or ulcers on their legs or feet This easy to use kit is completely portable and you can document the associated waveform for comparison over time It contains the photo plethysmograph photo transducer cuffs chart recorder battery charger chart paper carrying case and aneroid sohygmomanometer This kit is excellent for evaluating patients with calcified vessels non healing wounds diabetic feet or people who need toe pressures 21 TD312 Fo busy practices or clinics Hokanson away from you to inflate and pulled towards you to deflate with no manual pumping making cuff in flation easy The rechargeable battery makes this automated cuff inflator ready at all times just recharge over night When used with the NIVP3 Arterial and Venous Software the TD312 also provides a handy soft ware remote control When used as a standalone cuff inflator or with other Hokanson products the TD312 can store pressures and perform the ABI calculations for you this is very useful when doing ABI screening exams It can inflate any size cuff and remember the pressure for you The male metal fitting fits all standard Hokanson cuffs and the MV10 Cuff
25. he gauge is the same as the circumference of the limb or digit being measured This allows the Hokanson plethysmograph to relate resistance change to volume change The size for limb strain gauges should be 1 3 cm less that the circumfer ence of the limb so they will stretch slightly Digits strain gauge should be 0 5 cm less than the circumference of the digit Strain gauges have a shelf life due to oxidi zation so we build them to order and they are warranted for one year i okanson strain gauges are designed with a unique 4 wire construction For more information and other supporting documents please go to our website www hokanson cc Limb Set Forearm Set Digit Set Eight gauges from 22 to 36 cm in 2 cm increments Eight gauges from 16 to 30 cm in 2 cm increments Seven gauges from 4 5 to 7 5 cm in 0 5 cm increments Positioning Aids The active portion of the strain gauge should not touch anything outside of the limb during testing and the limb or digit should not move to prevent artifact Positioning foam blocks helps to position the patient in a comfortable way so they will not move during test ing All blocks are easily cleaned and can withstand years of use PAK8 An eight piece set of contoured foam blocks used to posi tion the legs arms hands and feet for plethysmography studies The PAK8 includes two of each piece shown here PAKS A five piece set similar to the PAK8 is designed for fore arm plethysmography st
26. her supporting documents please go to our website www hokanson cc i Eee 19 Portable ABI Kit Everything you need Diabetes Association the American Heart Association the American College of Cardiology and the American College of Physi cians as a basic screening examination for PAD Please see our website www hokanson cc for more information about PAD and ABI screening T he ABI is an easy noninvasive exam for peripheral arterial disease PAD screening This exam is recommended by the American og Ideal for screening at the bedside and other places m i where portability is needed The Portable ABI Kit For the Primary Care Provider or Home Health or Clinic the Portable ABI Kit has everything you need to perform accurate ABI s to identify patients with PAD who need further attention Results are documented in real time via the waveform printed on the strip chart recorder The green colored LED s flash provides the clinician a means to identify the sweet spot where the maximum arterial flow is located This Kit provides all the instruments and accessories needed in a convenient carrying case including a chart recorder for documentation It is ideal for clinics doing ABI screening home health physician s offices and hospitals that want to perform screening at the bedside and other places where portability is needed The Portable ABI Kit includes e MD6 Doppler This continuous wave bidirectional Doppler
27. ility of error For more information sample reports and other supporting documents please go to our website www hokanson cc MD35 Compact amp user friendly he MD35 is the Mobile physiological peripheral vascular system that is ideal for transporting the test to the patient via a van or car You can build out the system to suit your practice including computerization It is flexible versatile and reliable It is compact to meet your size constraints and can be computerized using your laptop or PC and printer Compact size light weight and small footprint make it ideal to fit on a shelf in a self contained lab in a van or in carrying cases for grab and go to an office Included is a CW bidirectional Doppler with a bifocal lens for superficial and deep vessels eliminating the need for two Doppler probes The Doppler probe has controls for volume waveform inversion and turning on off the chart recorder on the handle for your conve nience A photo plethysmography transducer and pneumo plethysmography are also provided You can perform all of the standard peripheral vascular physiological tests with the MD35 The MD35 has ten calibrated gain settings selectable AC artery or DC venous coupling and a two speed chart recorder for obtaining the best waveforms For more information sample reports and other supporting documents please go to our website www hokanson cc 1 800 999 8251 fax 425 881 1636 www hokanson cc 8 The follo
28. ingers and middle toes Large toe or penis Very large toe or penis Small toes and fingers Middle toes and fingers Large fingers and middle toes Large toe or penis Very large toe or penis SJJND 9 SOLIOSSADY Cuff Application Large and middle toes or penis Large toe or penis 31 Hokanson Vascular Cuff Sets Aae aeai TCPG60 amp TCPG3 ADP10 No more taping or pasting Adheres so well it cannot be removed 1 800 999 8251 fax 425 881 1636 www hokanson cc ascular Cuff Sets were designed to meet the general needs of peripheral vascular exams with a good selection of cuffs for nearly any sized limb or digit The VCS23 includes an assortment of cuff sizes and types to meet the requirements of any vascular lab two CC22 and two CC17 con toured Thigh Cuffs four SC10 and four SC12 Straight Segmental Cuffs two SC5 Tourniquet Cuffs one TMCZ Transmetatarsal Cuff six Digit Cuffs two in each width 1 6 1 9 and 2 5cm one UPC2 5 Digit Cuff and one UPC3 3 Digit Cuff The VCS14 Segmental Vascular Cuff Set provides all of the cuffs needed to perform bilateral segmental pressures and pulse volume recordings four SC10 Straight Segmental Cuffs six SC12 Straight Segmental Cuffs two TAC7 Transmetatarsal Cuffs and two UPC2 5 Digit Cuffs Thermal Chart Paper Chart paper is available for both the MD6VR Chart Recorder and the MD35 Chart Recorder The MD6V
29. it v v v Primary Care MD6 System MD35 CVS4 Toe Brachial Index TBI Package MD6 v vV Primary Care System MD35 CVS4 Post Exercise Pressures with Automatic MD35 CVS4 v v Primary Care ABI Calculation Upper amp Lower Extremity MD6 System MD35 v vV v Vascular Segmental Blood Pressure CVS4 Blood Pressure in All Limbs Portable ABI Kit v v v Vascular MD6 System MD35 CVS4 Carotid Doppler MD6 Doppler v Vascular MD35 Doppler MD6 Doppler v Hospital UW7 Doppler Systolic BP Portable ABI Kit v Hospital MD6 Doppler UW7 Doppler Post Revascularization Pulse Check MD6 Doppler v Hospital UW7 Doppler continues next page 1 800 999 8251 fax 425 881 1636 www hokanson cc 2 Tests and Applications Instrument Doppler PPG Pneumo Strain Specialty Gauge Thoracic Outlet Syndrome MD 6 MD35 v Vascular CVS4 Blood Pressure in All Digits Toe Pressure Kit v vV Vascular MD6 System MD35 CVS4 Toe Pressures Toe Pressure Kit v Primary Care MD6 System MD35 CVS4 Arterial Inflow EC6 Al v v Research Venous Occlusion Plethysmography Cold Sensitivity MD6 MD35 cvs Research Arterial Pressures and Qualitative ECO Aj Research Waveform Analysis Maximum Venous Outflow MD35 CVS4 EC6 Vascular Digit and Limb Pulse Volume Recording MD6 System MD35 v Vascular CVS4 The following index lists the location of every occurrence for each category instru
30. ler uses rechargeable NiCad batteries and is charged separately from the chart recorder When inserted on the input jack of the MD6VR chart recorder the waveforms from the Doppler can be recorded 1 800 999 8251 fax 425 881 1636 www hokanson cc 22 MD6 Pocket Doppler with Detachable Transducer This twin to the MD6 Doppler has a detachable cable that is 6 feet 1 8 meters long The controls and re chargeable battery are identical to the MD6 Doppler It can also be Handheld or pocket Dopplers the MD6 and the MD6 with Detachable Transducer Dopplers are ideal for locating difficult to find pulses or checking post operative pulses on vascular stents or revascularized sites For more information sample reports and other supporting documents please go to our website www hokanson cc Lan Useful in teaching situations where students hear Mmordnson pulse sounds simultaneously The UW7 Doppler provides both a removable Doppler transducer with an extra long cable and a large speaker for excellent sound This Doppler is very useful in a teaching situation where the instructor can locate the pulse and all of the students hear the sound simultaneously The UW7 does not have any print capabilities Hokanson 23 used with the MD6VR chart recorder for printing waveforms a1py Aipwilid The Al 4 complete automated system Al6 Automated Strain Gauge Plethysmography System he Al is the ideal arterial inflow system
31. lse volume recordings four cuff method SC12 13 x 85 cm Upper arm and upper leg for segmental pressure measurements and pulse volume recordings four cuff method SC12L 13 x 124 cm Upper thigh for segmental pressure measurements and pulse volume recordings four cuff method on large patients SCS 6 x 83 cm Arm or leg tourniquet cuff TMC7 7 5 x 40 cm Metatarsus or wrist Contoured Cuffs Contoured Cuffs provide better fit for large tapering legs or upper arms To use with E20 Rapid Cuff Inflation System or the RD2 Rapid Cuff Deflator cut off the female Luer fitting and plug on the end of each hose Contoured cuffs are also latex free and have a replaceable polyurethane bladder and washable blue nylon cover SJJND 9 SOLIOSSADY Model Overall Cuff Size Cuff Application CCIZ 18 x 108 cm Small to middle adult thigh for standard thigh blood pressures plethysmography segmental pressure measurements and pulse volume recordings three cuff method CC22 24 x 122 5 cm Large adult thigh for standard thigh blood pressures plethysmography segmental pressure measurements and pulse volume recordings three cuff method Hokanson 29 Specialized Cuffs Rapid version digit penile Rapid Version Cuffs studies The large inner diameter tubing facilitates almost instant inflation and deflation with the E20 AG101 Rapid Cuff Inflation Rss Version Cuffs are essential to successful rapid cuff inflation for v
32. ment or accessory in the catalog Where to find Vascular MD35 Mobile Vascular MD35 Procord System Option MD35 Procord System Basic Option Segmental Pressure Package Option NIVP3 Software TD312 Cuff Inflator Straight Segmental Cuffs Contoured Cuffs Durable Digit Cuffs Thermal Chart Paper RD2 Rapid Cuff Deflator MV 10 Segmental Cuff Selector MD6 System MD6 Bidirectional Doppler MD6RP Photo Plethysmograph MD6PN Pneumo Plethysmograph MD6VR Chart Recorder MD6 Doppler MD6 Pocket Doppler with Detachable Transducer Phlebology Venous Rapid Cuff Inflation System E20 Timers and Foot Switch Rapid Version Segmental Cuffs Contoured Cuffs Primary Care or Hospital Portable ABI Kit TBI Package Toe Pressure Kit TD312 Cuff Inflator MD6 Doppler MD6 Pocket Doppler with Detachable Transducer UW7 Doppler 1 800 999 8251 fax 425 881 1636 www hokanson cc 4 Where to find Research Studies Al6 Automated Strain Gauge Plethysmography System EC6 Strain Gauge and Photo Plethsymograph E20 AG101 Rapid Cuff Inflation System E20 Cycle Timer Strain Gauges Positioning Aids DS400 Aneroid Sohygmomanometer NIVP3 Arterial Inflow Software Accessories and Cuffs MV10 Segmental Cuff Selector RD2 Rapid Cuff Deflator Straight Segmental Cuffs Contoured Cuffs Rapid Version Straight Segmental Cuffs Replacement Bladders for Cuffs Durable Latex Free Digit Cuffs Durable Latex Digit Cuffs Disposable Digit Cuffs Vascular Cuff S
33. ndustry standard Hokanson has both Mercury and Indium Gallium strain gauges for limbs and digits and can build to suit special orders The EC6 supports a Hokanson infrared photo transducer for pulse detection for use in blood pressure and venous reflux testing Choose the documentation method that best suits your application The RS232 digital output connects to NIVP3 Software for documentation and automated controls of E20 AG101 or con nect to their own third party software application The analog output allows connectivity to a wide range of both software or strip chart recorder options from third parties The EC6 analog output may be AC or DC coupled for arterial and venous tests The output is adjustable from 200 mV and seven sensitivity ranges span 2 8 full scale to 0 02 volume change per division on the meter Autobalance is available which resets the signal whenever it goes beyond the scale of the instrument s meter Calibration and zeroing of the output is performed with one button or by a remote signal The NIVP3 Segmental Arterial amp Venous Exams Software can be used with the EC6 Plethysmograph to perform penile pressures and plethysmography venous reflux and maximum venous outflow MVO exams E20 AG101 Rapid Cuff Inflation System Hokarnsor e Cycle Timer www hokanson cc 25 The E20 AG101 can be used in conjunction with the EC6 for arterial inflow test ing The E20 provides nearly instantaneous venous
34. of these instruments please visit our website at www hokanson cc Hokanson provides you with a choice of Dopplers as well as photo pneumo and strain gauge plethysmography instruments Many tests can be performed using several modes with some modes working better than others depending on the site to be tested Additionally Hokanson has cuff inflators including sphygmomanometers automated and rapid inflation deflation to meet your various testing needs We are the major vascular cuff manufacturer with digit and segmental cuffs in a wide variety of sizes and types Hokanson instruments cuffs inflators and accessories are all made in the USA Key to matrix Vascular Includes vascular labs vascular surgeons cardiovascular surgeons and cardiologists Phlebology Includes vein clinics vein specialists and vascular surgeons Primary Care Includes internists family practice home health or clinics and hospitals Research Includes researchers in diabetes endovascular function and arterial inflow studies Tests and Applications Doppler PPG Pneumo Strain Specialty Gauge Upper amp Lower Extremity Arterial amp Venous Doppler v Vascular Ti E OO O Upper amp Lower Extremity Segmental Blood Pressure E Aaa ae Ss Se medresenin Yar Pied sae A nb 0 a tr a Digit and Limb Pulse Volume Recording Vascular er Vascular Carotid Doppler V V Penile Pressure and Plethysmography v V Thoracic Outlet Syndrome Vascular
35. outflow facilitating the EC6 s measurement of the arterial inflow rate The E20 AG101 also deflates a cuff in stantaneously so that it can be used for the maximum venous outflow MVO exam The E20 AG101 may be used to perform reactive hyperemia as its regulator will maintain the set cuff pressure as long as is desired When used with the NIVP3 Software for arterial inflow or MVO tests you can automate the inflation hold deflation to meet the needs of your study s protocol The Cycle Timer is optionally installed inside the E20 at the factory The cycle timer is ideal for arterial inflow studies where the NIVP3 Arterial Inflow software is not used The Cycle Timer has two timers accessible on the front of the instrument With the Cycle Timer you can repeat the cycle of inflation deflation automatically and indefinitely First select the pressure for inflation with the dial on the E20 then select a time to maintain the inflation and the interval between inflations on the Cycle Timer and the E20 will perform this inflate hold deflate cycle For more information and other supporting documents please go to our website Hokanson udipasay Strain Gauges The industry standara Strain Gauge Sets Sizes that has been the industry standard for over 30 years Strain Gauges are available in either Mercury or Indium Gallium and are ordered by size and type limb or digit The strain gauges are designed so that the active portion of t
36. ssure measurements and pulse volume recordings four cuff method SC 120m 13 x 124 cm Upper thigh for segmental pressure measurements and pulse volume recordings four cuff method on large patients SCS 6 x 83 cm Arm or leg tourniquet cuff TMC7 7 5 x 40 cm Metatarsus or wrist Contoured Cuffs CCIZ7 18 x 108 cm Small to middle adult thigh for standard thigh blood pressures plethysmography segmental pressure measurements and pulse volume recordings three cuff method CC22m 24 x 122 5 cm Large adult thigh for standard thigh blood pressures plethysmography segmental pressure measurements and pulse volume recordings three cuff method 11 MD35 Cuffs Digit or penile testing the same sizes Like limb cuffs digit cuffs should fit well but not too snug or too loose The length of the digit cuff should be longer than the circumference of the digit where the cuff will be applied It is desirable for the cuff length to overlap itself in order to get an accurate pressure measurement Digit cuffs can be cleaned by wiping with a soap and water solution and then rinsing D urable digit cuffs can be used for all digit or penile testing Please note that there is a choice between latex and latex free cuffs in Do not clean latex cuffs with alcohol products it will destroy them Durable latex free polyurethane cuffs Model Overall Cuff Size Cuff Application UDC1 6 1 6 x 9 cm Small toes and fingers UDC1 9 1 9 x
37. t Switch The Foot Switch provides remote inflation deflation whenever you need it Stepping on the Foot Switch either inflates or deflates keeping your hands free for other tasks For more information and other supporting documents please go to our website www hokanson cc Rapid Version Cuffs Rapid Version Cuffs have large inner diameter tubing so the cuff can inflate and deflate almost instantaneously They are not designed for taking standard blood pressures or for use with Luer fittings Rapid Version Straight Segmental Cuffs Model Overall Cuff Size SC 10D 11 x 85 cm SC12D 13 x 85 cm Fitted with D version tubing AB6ojoq jyd Cuff Application Upper arm and lower leg for plethysmography and venous reflux measurements Upper arm and lower leg for plethysmography and venous reflux measurements For large legs and arms that taper this cuff gives a better fit with even pressure application around the limb To use with the rapid cuff inflation system cut off the Luer fittings on the large tubing Contoured Cuffs CC17 ix 10S em CC22 24 x 122 5 cm Small to middle adult thigh for standard thigh blood pressures plethysmography segmental pressure measurements and pulse volume recordings three cuff method Large adult thigh for standard thigh blood pressures plethysmography segmental pressure measurements and pulse volume recordings three cuff method For more information and ot
38. the attached inflated cuff MV10 Segmental Cuff Selector The MV 10 facilitates rapid switching from one cuff to another for pulse volume recordings PVR s segmental pressure exams or even speeding up an ABI exam The MV10 is compatible with the TD312 or the RS400 The cuff inflator attaches to the connector at the base of the MV10 and up to 10 cuffs can be connected to the hoses To switch between cuffs to inflate and deflate flip the toggle switch No power is required and it fits all sizes and types of Hokanson vascular cuffs No power required and fits all sizes and types of Hokanson vascular cuffs 13 ADINISDA MD6 System Portable easy to use anywhere It is not computerized and has a strip chart recorder for easy documentation The chart recorder paper has an adhesive backing so you just print and press on the patient record Both the Doppler and Chart Recorder run on rechargeable batteries so you do not need AC power when using the system gt ortable compact and easy to use The MD6 System is a complete physiological peripheral vascular testing system that you can take MD6 Bidirectional Continuous Cam Wave Doppler At 9 ounces the MD6 is a small compact pocket Doppler The high d f oleleeletes quality audio signal uses Dynamic Noise Reduction DNR and is ria stetetetatatats easy to hear even in a noisy room The patented red and green LEDs atatatetete on the end of the Doppler probe sho
39. the slope based on the cursor positions Hokanson 27 Accessories amp Cuffs A tll line ULLAL erm SE MV10 Segmental Cuff Selector he MV10 facilitates rapid switching from one cuff to another for segmental pressures pulse volume recordings or even speeding T up an ABI exam This segmental cuff selector works well with TD312 the DS400 or the E20 Rapid Cuff Inflator The cuff inflator attaches at the female Luer connector at the base of the MV10 and up to 10 cuffs can be connected to the hoses To switch between cuffs to inflate and deflate flip the toggle valve associated with the appropriate cuff No power is required and it fits all of the sizes and types of vascular cuffs via the male Luer fitting on each hose RD2 Rapid Cuff Deflator The RD2 plunger releases the air from a vascular cuff rapidly and completely for venous outflow mea surements it can be used with the contoured thigh cuffs and rapid version straight cuffs The RD2 also works well with either the DS400 or the TD312 Pushing in the plunger quickly exhausts the pressure from the attached cuff The unique connection system that is also used for the E20 Rapid Cuff Inflator provides maximum cuff exhaust rate Note that the RD2 is not required if you are using the E20 Rapid Cuff Inflator Works well with either the DS400 or TD312 1 800 999 8251 fax 425 881 1636 www hokanson cc 28 Vascular Cuffs Hokanson is the primary manufacturer of vascular cuffs
40. thysmography are that it is simple to use and clean waveforms are easy to obtain multiple cuffs can be applied to several parts of the body and then measured in quick succession Uses include pulse volume recording PVR and maximum venous outflow Hokanson 35 Hokanson Policies Warranty e Hokanson electronic instruments carry a five year warranty Instruments are warranted against defects in parts workmanship and performance for a period of five years from the date of delivery provided that they have not been abused or repaired by an unauthorized person e Transducers strain gauges blood pressure cuffs and accessories are warranted for one year e Batteries are excluded from this warranty e Repair is free of charge when the instrument is returned prepaid Return shipment will be made at our expense in a manner similar to your shipment to us If for any reason we are unable to repair your instrument within three working days we will provide a free loaner instrument at our expense Service Policy Hokanson will service any instrument we have ever manufactured regardless of the manufacture date Rental and loaner instruments are available to the customer under the following conditions 1 If repair takes more than three working days we will furnish a free rental instrument loaner at our expense Freight charges will be the responsibility of D E Hokanson Inc 2 Ifthe instrument is within the warranty period and th
41. udies It includes two of each size wedge and one U shaped block 1 800 999 8251 fax 425 881 1636 www hokanson cc 26 DS400 Aneroid Sphygmomanometer The DS400 is a reliable sturdy handheld sohygmomanometer that has a 10 year warranty on the calibration The grip is ambidextrous and very comfortable and the trigger release is easy to use and gives you good control over the deflation rate It can inflate all of our cuffs except those designed for rapid cuff inflation non Luer fitting It can also be used with the MV10 Cuff Selector and the RD2 Rapid Cuff Deflator A Comfortable grip and easy to use trigger release NIVP3 Arterial Inflow Software B alexander jim ID 987 visit index 6 Generates complete patient reports with waveforms demographics and tabular data yudipasay Stage No 1 of 2 The NIVP3 Arterial Inflow Software simplifies your test protocols and inflow calculations and provides you with the automation of balancing the strain gauge plethysmograph cuff inflation and deflation using the E20 AG101 and storing the inflow waveforms The NIVP3 software assists you in making slope calculations to measure the inflow rate It generates patient reports that are complete with plethysmographic waveforms patient demographics and tabular data Analyzing the waveform slope allows you to set the cursors including a hotkey for locating the closest waveform peaks to the cursors and calculates
42. vides a handy software remote control The TD312 can store pressures and perform the ABI calculations for you this is very useful when doing ABI screening exams It can inflate any size cuff and remember the detected pressure for you and calculate the ABI The male metal fitting fits all standard Hokanson cuffs and the MV10 Cuff Selector T he TD312 Calculating Cuff Inflator is ideal for busy practices or large screening clinics The thumb For taking segmental pressures during deflation of the cuff when the Doppler signal returns at each site push the Store button to save the pressure reading up to 12 pressures can be stored in the memory You can recall the stored pressures when in memory mode as well as select the pressures to use to calculate the Ankle Brachial Index or Toe Brachial Index ca TD 312 www hokanson cc For more information sample reports and other supporting documents please go to our website FIRE T Thermal Chart Paper TCP10 5 cm wide plain paper for MD6VR and legacy MD6R package of 10 rolls ADP10 5 cm wide plain adhesive backed paper for MD6VR and legacy MD6R package of 10 rolls Chart paper is available for the MD6VR Chart Recorder The MD6VR has the option of adhesive backed thermal chart paper so you just print remove the backing and adhere it to the patient record with no more taping or pasting and it adheres so well that it cannot be removed For more information please go to our website www
43. w you visually when the probe is over the best place for a signal Green means flow towards the probe or arterial blood When the probe is over a vein or detects retrograde flow the red LED lights to indicate flow away from the probe To get an audio stereo effect for distinguishing blood flow purchasing op tional stereo earphones allows you to hear flow towards the probe in the left ear and flow away from the probe in the right ear The controls for Doppler on off and chart recorder on off are conve niently on the probe for easy access with your index finger or thumb The Doppler uses rechargeable NiCad batteries and is charged separately from the chart recorder When inserted on the input jack of the MD6VR chart recorder the waveforms from the Doppler can be recorded The red and green LEDs show the best place for a signal 1 800 999 8251 fax 425 881 1636 www hokanson cc 14 MD6RP Photo Plethysmograph ih in The Infrared based PPG photo plethysmograph facilitates digit pressures and waveforms with ease and accuracy The diodes have a Velcro attachment for secure fitting to digits The plethysmo graph plugs into the input jack and draws its power from the chart recorder ADINISDA The MD6PN facilitates pulse volume recordings by detecting pressure changes in a sensing cuff applied to the patient s limb The pulse volume recording waveform shapes and amplitudes can be compared between sites on the patient s bod
44. wing options were created to meet the typical customers needs Option MD35 Procord System This system includes 4 segmental cuffs and one contoured thigh cuff and several digit cuffs for the basic tests and the DS400 Aneroid sohygmomanometer and RD2 Rapid Cuff Deflator This option takes the place of the basic MD35 instrument and includes everything in the basic MD35 Option MD35 Procord Basic This is the basic MD35 instrument with transducers and start up supplies This system is ideal for the lab with existing cuffs or so you can choose your own custom cuff set Option Segmental Pressure Package Supplemental to the MD35 is the segmental pressure package with extra cuffs for complete segmental pressure and PVR studies and the MV 10 segmental cuff selector ADINISDA NIVP3 Software Consistent reporting Segmental Arterial amp Venous Exams Software T his software comes with the complete CVS4 system and is available for the MD35 mobile unit to create consistent tests with computerized test results and reporting NIVP3 captures stores and prints physiologic studies of upper and lower extremity arteries and veins There is a spectral Doppler option available for use with the MD35 Procord which includes the ability to record and playback the Doppler waveforms and associated audio You can edit the demographic data and signs amp symptoms questions to meet your practice s needs When printing out reports
45. y time no matter the size of the cuff or limb Simply dial in the pressure needed and push the button for inflation and then push the button to deflate The E20 s large digital readout displays cuff pressures accurately to within 1 mmHg over a range of O to 300 mmHg The E20 requires a source of clean compressed air and the AG101 is the perfect companion The AG101 has the capacity to allow the E20 to inflate a large contoured thigh cuff every 12 seconds indefinitely Special care has been taken to make the compressor quiet compact and dependable so it is ideally suited for your exam room For more information and other supporting documents please go to our website www hokanson cc Along with the Rapid Cuff Inflation System you select the option to have a 3 Second Timer or a Foot Switch and also the cuffs that you will need to meet your patient needs 3 Second Timer Set the pressure on the E20 and when you are ready to scan the leg just push the but ton on the 3 Second Timer and the cuff inflates in 0 3 second holds the pressure for 3 seconds and then deflates instantaneously it is accurate reliable and easy No need for a second person and no worries about the consistency or reproducibility and accu racy of the pressure timing or results Saves time money and your back For more information and other supporting documents please go to our website www hokanson cc 1 800 999 8251 fax 425 881 1636 www hokanson cc 18 Foo
46. y to indicate the segment where disease may be present The MD6PN plugs into the input jack on the chart recorder and draws its power from the MD6VR Real time waveforms and bloodflow information are produced for hard copy clinical reports o aaj The MD6VR creates a real time chart recording of bloodflow information or waveforms directly from the following instruments the MD6 Doppler the MD6RP Photo Plethysmo graph and the MD6PN Pneumo Plethysmograph This chart recorder has rechargeable batteries so you can use it anywhere The controls are simple soft buttons and an LED r 14 fog Gh 15 16 IB 4 bar graph indicates the waveform position and reflects pulsation There are 5 print paella sea speed settings six range settings for plethysmographs and three range settings for d gt the Doppler Date and time are printed at the start of each recording and the chart recorder speed and range are also printed along the edge of the chart paper For more information and other supporting documents please go to our website www hokanson cc 15 TD312 Calculating Cuff Inflator wheel is pushed forward away from you to inflate the attached cuff and pulled towards you to deflate with no manual pumping making cuff inflation easy The rechargeable battery makes this automated cuff inflator ready at all times during your busy day and can be left to charge overnight When used with the NIVP3 Arterial and Venous Software it pro