1. ccccccecceccsseceeseseeeeeseeeeeseeeeeeseeaeeesseeeeesaaeeees 5 Changing the Operating Thermostat cccccccccccsseeeeeseeeeeceeeseseeeseeesseeseeeseeeeseas 5 CIA SY Seca sees essa eee T 5 RCE OF WI e mere 5 Whitehall Splint Pans Table se jectrsoodacentssataqoesanasycanvesetuog aepnneavacencageasmeevanetecaceemomis be 6 Model Diagram for SP 1501 basse cedee aoesceesopcrgcentnen eteaeedeentaenensrosearecaaenpsesesacdaieeecees 7 Electrical Diagram for SP 1501 cc ceccccecceceeeeeeeeeeeseeeceeeeeseeeeesaeeeesseeeeseeeeesaeees 8 Model Diagram for SP 1502 E a 9 Electrical Diagram for SP 1302 10 Electrical Parts Disassembly for SP 1501 aussen erm eere dti ebute Pe e Ene tetens 11 Electrical Parts Disassembly for SP 1502 cccceecccsseeeceeeeeseeeeeceeeeseneesseeeseas 12 WHY FORMA SPLINTS Forma Splint Pans are made out of durable stainless steel to resist corrosion The heating element has also been specially designed to insure even heating of the splinting material Both models feature variable temperature settings and a convenient drain Grounded plugs and high heat safety switches are standard Model SP 1501 has a spacious interior that accommodates splinting sheets up to 24 x 18 61cm x 46cm Model SP 1502 has a compact design that makes it universally ideal for clinical use The unit accommodates sheets up to 19 x 11 48cm x 28cm WHITEHALL MANUFAC
2. Skills Training Operators using the whirlpool need a working knowledge of Operator trainees need to occupational therapy procedures be trained in occupational therapy A WAR N i N G protocols read and understand this manual Only trained personnel should operate the Splint Pan Untrained operators can cause injury or be injured WHITEHALL MANUFACTURING P O BOX 3527 City of Industry CA 91744 0527 U S A Phone 800 782 7706 626 968 6681 Fax 626 855 4862 Web www whitehallmfg com Instructions for Operation and Care of Forma Splint Thermal Bath INSPECTING THE SPLINT PAN This Whitehall product has been carefully packaged at the factory to minimize the possibility of damage during shipping Inspect the packaging for external signs of damage Inspect the contents for damage If there is visible damage to the instrument upon receipt inform the shipping company and Whitehall immediately SET UP INSTRUCTIONS A WARNING Do not attempt to operate this equipment if there is evidence of shipping damage or you suspect the unit is damaged Damaged equipment may present additional hazards to you Contact Whitehall technical support for advice before attempting to plug in and operate damaged equipment 1 Your new Splint Pan includes the following 1 Heating Appliance 1 Power Cordset 1 Warranty Registration Card 1 Operation amp Maintenance Manual NOTE If you are missing any
3. wens mem m 7 Spes mms CITIII Fuse 8 Amp 220V Time Delay 5mm x 20mm pf EM San meaner Ix1 0710 203 000 Fuse 4 Amp 220V Time Delay 5mm x 20mm ENENENEN wem TI A E nq n Light Rectangular Green 125VAC r Light Rectangular Green 250VAC opt o Light Round Amber 125VAC CLs Light Round Amber 250VAC Pf ff Light Round Green 125VAC fe Light Round Green 125VAC a 13 bd ee Light Round Green 250VAC i t ye aw RR E 17 meme Power Switch 3 Way NE MAN Repos CA 91744 0527 U S A Phone 800 782 7706 626 968 6681 Fax 626 855 4862 Web www whitehallmfg com Instructions for Operation and Care of Forma Splint Thermal Bath Ea Ki sci IST TET Fe tl Ln III Ld Leinen lanes inca I IR RN Le sic una RR RR RR RR RN 6903 338 001 Rim Stainless Steel Lid not included SP 1501 SLD te ft B 6903 195 001 Sliding Lid Assembly Stainless Steel SP 1501 SLD LII Ll 6903 142 000 Thermometer Digital Fahrenheit 120V Only bl 6903 143 000 Thermometer Digital Celsius 220V Only 6903 150 000 Thermostat Capillary Operating 6502 100 000 8 32 x 3 8 Phil Pan Head Screw 45 0116 013 000 10 32 x 3 4 SST Phil Round Head Screw Pox box laaj s 6900 144 000 1 4 Clear Plastic Drain Hose Not Shown WHITEHALL MANUFACTURING P O BOX 3527 City of Industry CA 91744 0527 U S A Phone 800 782 7706 626 968 6681 Fax 626 855 4862 Web
4. www whitehallmfg com Instructions for Operation and Care of Forma Splint Thermal Bath MODEL SP 1501 MODEL SP 1501B ion ee FC ay wr ALL FACTURING BOX PX of M Sn N 40 Jndustry EA 91244 0527 U S A P oe 800 782 7708026 2 1 M44 M5 1 968 6681 Fax 626 855 4862 Web www whitehallmfg com Instructions for Operation and Care of Forma Splint Thermal Bath THERMOSTAT DPDT SP 1501 SWITCH BLK XN A BLK l HI LIMIT i BLK ey UTER INLET FUSE 1 SENSOR THERMOMETER MOUNT TO TANK ower SA lt MBK A a BK HEATING GRN YEL LED LIGHT 7 BLK ud UPPER i HI LIMIT FUSE 2 SENSOR LED LIGHT aii ric ia WHT WHT WHT WHT i OPERATING THERMOSTAT GND Use only Time Delay Fuse See Parts List Page 6 Item 16 DPDT THERMOSTAT D 4 SWITCH BRN by SP 1501B SBRN POWER INLET am oet FUSE 1 SENSOR THERMOMETER N BRN _BRN ty n fi _ PROBE MOUNT TO TANK BRN LOWER 4 4 OS BRN iie GRN YEL LED LIGHT BRN p I HI LIMIT 4j UPPER FUSE 2 SENSOR LED LIGHT RE BLU BLU BLU E d OPERATING THERMOSTAT GND Use only Time Delay Fuse HI LIMIT See Parts List Page 6 Item 17 Protective Conductor Terminal The protective conductor terminal symbol in the above figure identifies the location of the bonding terminal which is bonded to conductive accessible parts of the enclosure for safety purposes symbols on labels WHITEHALL MANUFACTURING P O BOX 3527 City
5. circumstances for incidental consequential or direct charges caused by defects in the materials or any delay in the repair or replacement thereof This warranty is in lieu of all other warranties expressed or implied Product maintenance instructions are issued with each fixture and disregard or noncompliance with these instructions will constitute an abnormal use condition and void the warranty If you have any questions or require technical assistance please call 800 743 8219 NOTICE TO KEEP ORIGINAL PACKAGING Regarding warranty claims customer must retain original packaging for one year upon receipt of product If packaging is discarded it is the customer s responsibility to provide adequate packaging Any shipping claims that are a direct result of customer provided packaging materials will be handled by the shipper Z MORRIS GROUP Member of
6. grasping device such as tongs to remove splint material from HOT water e DO NOT use in the presence of flammable liquids or gases as these may present a fire and or explosion hazard e ALWAYS allow the appliance to cool down before draining water or moving unit e DO NOT use the lid handle to lift or transport appliance e NEVER leave appliance operating unattended for long periods of time Water can evaporate and cause appliance to overheat which may result in damage to the heating element Turn OFF when not in use FOLLOW spline HALE MANPF AST PBINGidnh9 1S rer mn Stare ndastur Cn fdr R Akusitration Phone 800 782 7706 626 968 6681 Fax 626 855 4862 Web www whitehallmfg com WHITEHALL MANUFACTURING P O BOX 3527 City of Industry CA 91744 0527 U S A Phone 800 782 7706 626 968 6681 Fax 626 855 4862 Web www whitehallmfg com Instructions for Operation and Care of Forma Splint Thermal Bath TABLE OF CONTENTS WAY FOF DIFIIS eee sonst cepa aues cx amt ctu Es asumen E EE EEEE EEE a EEE EEEE 2 Model Descriptions Tor SP TDO T us ados eu chtoe dob psc pa tto dite t ate dageenecsasnteanestematousas Fees 2 Model Descriptions for SIP 1502 s seoetaemusco anat Lo se xp dos ep Yu xu data uo bap receptui de aout 3 incite qmm E 4 ROMOV O NOT t c 4 Cleaning M 4 ANTI TIPO WINS TS AU o RETE 4 To Change Temperature Settings
7. of Industry CA 91744 0527 U S A Phone 800 782 7706 626 968 6681 Fax 626 855 4862 Web www whitehallmfg com Instructions for Operation and Care of Forma Splint Thermal Bath few Alternating Voltage or Current ct Fuse Location MODEL SP 1502 MODEL SP 1502B uii s 85 Ec mK _ FUSE 1 IN er f eV FUSE 2 u rail a ar uA E E eo my 44 LR WHITEHALL MANUFACTURING P O BOX 3527 City of Industry CA 91744 0527 U S A Phone 800 782 7706 626 968 6681 Fax 626 855 4862 Web www whitehallmfg com Instructions for Operation and Care of Forma Splint Thermal Bath SP 1502 DPST OVER TEMP OPERATING POWER INLET FUSE 4 SWITCH SENSOR THERMOSTAT L BLK X _ BLK BLK BLK _ BLK HEATING ELEMENT GREEN Ta AMBER YELIGRN LED LIGHT LED LIGHT FUSE 2 WHT WHT WHT TE THERMOMETER PROBE MOUNT TO TANK GND Use only Time Delay Fuse See Parts List Page 6 Item 18 SP 1502B DPST OVER TEMP OPERATING POWER INLET FUSE 1 SWITCH SENSOR THERMOSTAT ELEMENT GREEN lt gt lt gt AMBER YEL GRN LED LIGHT Y LED LIGHT FUSE 2 BLU BLU BLU M THERMOMETER PROBE MOUNT TO TANK GND Use only Time Delay Fuse See Parts List Page 6 Item 19 Protective Conductor Terminal The protective conductor terminal symbol in the above figure identifies the location of the bonding terminal which is bonded to conductive accessible parts of the encl
8. of the above contact WHITEHALL MANUFACTURING toll free telephone no 800 782 7706 or 626 968 6681 2 Unpacking your Splint Pan Remove all shipping amp packaging material Remove all items from inside of tank such as Power Cordset Filler Hose Warranty Registration Card and Operation amp Maintenance Manual 3 Location of your Splint Pan Place the Splint Pan at a convenient height amp location such as on a table or scratch resistant counter top IMPORTANT Appliance must be placed on a level surface Splint Pan must be positioned so to allow ease of disconnecting Power Cordset if necessary 4 Preparing to Fill your Splint Pan Make sure appliance is unplugged and all packaging has been removed from reservoir Ensure that the inside of tank is thoroughly clean before filling with water DO NOT use any medium except water Check drain valve and make sure handle is in the closed position by turning clockwise to make certain no water in tank will drain out of appliance while being filled Inspection Checklist Is the Splint Pan free of excessive wear Is a properly grounded and voltage matched receptacle available Is the outlet equipped with a functioning GFI Does the drain valve open and close properly 5 Filling your Splint Pan Appliance must be unplugged Fill reservoir with water to at least 3 76mm deep Ball valve closed lC Booo i SET UP INSTRUCTIONS continued 6 Preparing to
9. 27 U S A Phone 800 782 7706 626 968 6681 Fax 626 855 4862 Web www whitehallmfg com UU E Manufacturing Mailing Address P O Box 3527 City of Industry CA 91744 0527 U S A Physical Address 15125 Proctor Avenue City of Industry CA 91746 U S A Phone 800 782 7706 626 968 6681 Fax 626 855 4862 Web www whitehallmfg com E mail info whitehallmfg com Any questions regarding servicing of products in Europe or the Middle East should be directed to Niva Medical Company Olarinluoma 14 B FIN 02200 Espoo Finland Phone 358 9 615 00 540 Fax 358 9 615 00 545 Web www nivamedical fi e E mail info nivamedical fi MANUFACTURER S WARRANTY Whitehall Manufacturing Company warrants that its products are free from defects in material or workmanship under normal use and service for a period of one year from date of shipment Whitehall s liability under this warranty shall be discharged solely by replacement or repair of defective material provided Whitehall is notified in writing within one year from date of shipment F O B Industry California This warranty does not cover installation or labor charges and does not apply to materials which have been damaged by other causes such as mishandling or improper care or abnormal use The repair or replacement of the defective materials shall constitute the sole remedy of the Buyer and the sole remedy of Whitehall under this warranty Whitehall shall not be liable under any
10. INSTRUCTIONS FOR OPERATION AND CARE OF S PLINT BATH FORMA THERMAL SP 1501 SP 1502 Q SP 1501 Q SP 1501 SLD Q SP 1502 Q SP 1501B Q SP 1501B SLD Q SP 1502B Manufaciuring P O Box 3527 City of Industry CA 91744 0527 U S A 800 782 7706 626 968 6681 www whitehallmfg com 6900 101 000 April 2013 WARNING PLEASE READ THIS ENTIRE BOOKLET BEFORE OPERATING YOUR NEW SPLINT PAN Failure to follow these instructions could result in damage to your new heating appliance and or injury European Union CE Mark C The presence of the CE Mark on Whitehall equipment means that it has been designed tested and certified as complying with all applicable European Union regulations and recommendations ar Waste Electrical and Electronic Equipment WEEE This symbol on the product or on its packaging indicates that this product must not be disposed of with regular waste Instead it is the user s responsibility to dispose of waste equipment according to the local laws Separate collection and recycling of the waste equipment at the time of disposal will help conserve natural resources and ensure it is recycled in a manner that protects human health and the environment For information about where the user can drop off the waste equipment for recycling please contact your local waste collection authority See pages 11 and 12 for instructions on how to disassemble the equipment for recycling purposes Electric S
11. TURING P O BOX 3527 City of Industry CA 91744 0527 U S A Phone 800 782 7706 626 968 6681 Fax 626 855 4862 Web www whitehallmfg com Instructions for Operation and Care of Forma Splint Thermal Bath MODEL SP 1501 Double Lids 100 120 Volts 50 60 Hz 15 Amps MODEL SP 1501B 200 240 Volts 50 60 Hz 8 Amps Shown with Double Lids sliding lid Model SP 1501 SLD also available Environmental conditions recommended 41 F to113 F 5 C to 45 C lt 90 RH Stainless Steel Working Bath Drain and Drain Valve High or Low Temperature INSIDE DIMENSIONS Contro 24 1 2 x 18 1 2 x 5 Deep Operating 622mm x 470mm x 127mm Deep Indicator Light 4 28 1 2 _____ 21 720 530 MODEL SP 1502 100 120 Volts 50 60 Hz 6 Amps Environmental conditions recommended 41 F to 113 F 5 C to 45 C lt 90 RH MODEL SP 1502B 200 240 Volts 50 60 Hz 4 Amps WHITEHALL MANUFACTURING P O BOX 3527 City of Industry CA 91744 0527 U S A Phone 800 782 7706 626 968 6681 Fax 626 855 4862 Web www whitehallmfg com Instructions for Operation and Care of Forma Splint Thermal Bath Large Stainless Steel Lid Drain and Drain Valve Variable Temperature Control Operating Indicator Light INSIDE DIMENSIONS 19 1 2 x 11 7 8 x 4 1 2 Deep 500mm x 300mm x 110mm Deep 23 1 2 14 1 4 600 7C 860
12. hock A The Electric Shock Symbol is used to indicate a hazard arising from dangerous voltage Any mishandling could result in irreparable damage to the equipment and or personal injury or death General Warning or Caution The Exclamation Symbol appears in Warning and Caution statements This symbol designates where personal injury or damage to the equipment is possible WARNING To avoid electric shock connect the instrument to properly earth grounded GFCI protected 3 prong receptacles only Failure to observe this precaution can result in severe injury e DO NOT operate the appliance without properly filling with water Under no circumstance should the appliance be operated without water as operating the appliance without water may result in damage to the heating element Appliance must be unplugged while filling or emptying water e CONNECT the appliance into a properly polarized G F C I Ground Fault Circuit Interrupter electrical receptacle for protection against electrical shock Have a qualified electrician verify the wall socket is properly polarized and grounded Use only the power cordset provided with the unit The Splint Pan appliance must be properly grounded AVOID skin contact with HOT water at all times Carefully place splinting material into the Splint Pan appliance to avoid splashing onto skin or coming into contact with HOT water DO NOT reach into HOT water with bare hands to remove heated splint material Use a
13. l at all times Immediately fill the appliance with water to 3 76mm deep Avoid allowing water to reach a very low water level A very low water level would be any water level 3 4 20 mm or less water depth as measured from the tank bottom Never operate appliance without water These precautions will prevent the appliance from over heating and prevent potential damage to the heating element EMPTYING YOUR SPLINT PAN Before emptying draining your appliance be sure that the power switch is set to OFF Allow the appliance to cool down before emptying Lifting the lid will accelerate this cooling The Splint Pan must be unplugged when emptying the reservior The appliance has been provided with a Drain Valve that has a 1 4 6 35mm barbed nipple to attach a hose CARE amp CLEANING OF YOUR SPLINT PAN Turn power switch OFF and unplug the unit from the electrical receptacle If necessary drain the appliance by following instructions as outlined in the EMPTYING YOUR SPLINT PAN section When cleaning rinsing and or drying your appliance always rub in the direction of the stainless steel grain lines to minimize marring or scratching the surfaces Use mild soaps gentle non abrasive detergents or mild mixtures of ammonia to routinely clean the surfaces of the appliance Be sure to always rinse with clean warm water and wipe dry Use stainless steel cleaners such as 3M Stainless Steel Cleaner Polish Sheila Shinee T
14. osure for safety purposes symbols on labels few Alternating Voltage or Current Fuse Location WHITEHALL MANUFACTURING P O BOX 3527 City of Industry CA 91744 0527 U S A Phone 800 782 7706 626 968 6681 Fax 626 855 4862 Web www whitehallmfg com Instructions for Operation and Care of Forma Splint Thermal Bath ELECTRICAL PARTS DISASSEMBLY MODEL SP 1501 MODEL SP 1501B lt gt ie High Limit J og Sensor Thermostat a Noe J Operating Cu of Thermostat a Bm Cu i gt b u Fuse gi Lp uA in P c E W e a T E Fuse Holder Heating Element T E 3 b gt Digital F i i Thermometer Lights Switch ELECTRICAL PARTS DISASSEMBLY WHITEHALL MANUFACTURING P O BOX 3527 City of Industry CA 91744 0527 U S A Phone 800 782 7706 626 968 6681 Fax 626 855 4862 Web www whitehallmfg com Instructions for Operation and Care of Forma Splint Thermal Bath MODEL SP 1502 MODEL SP 1502B a n d E Heating Element S s Fuse A NN i s p B M Fuse Holder w StL wo 27 High Limit Su TEUNAN A Sensor Digital 5 i Thermometer Operating Lights Switch Thermostat WHITEHALL MANUFACTURING P O BOX 3527 City of Industry CA 91744 0527 U S A Phone 800 782 7706 626 968 6681 Fax 626 855 4862 Web www whitehallmfg com Instructions for Operation and Care of Forma Splint Thermal Bath WHITEHALL MANUFACTURING P O BOX 3527 City of Industry CA 91744 05
15. turn ON your Splint Pan Close lid Lid can pinch fingers Locate the Power Switch at front of the appliance and make sure it is set to OFF Insert connector end of power cordset into power inlet at back of appliance Connect plug end of power cordset into a G F C l protected AC electrical receptacle 7 Turning ON your Splint Pan You are now ready to turn ON the appliance Locate the Power Switch at the front of the unit and press to ON position 8 Adjusting Setting the Heat Up Temperature To change the set temperature on the model SP 1501 drain the water and unplug the unit Carefully remove the four screws holding the nameplate and locate the two thermostat knurled knobs The top knob is the thermostat for the high temperature limit setting and the bottom knob is the thermostat for the low temperature limit setting Insert a small screwdriver into the slotted head of the thermostat knob turning clockwise to raise the WHITEHALL MANUFACTURING P O BOX 3527 City of Industry CA 91744 0527 U S A Phone 800 782 7706 626 968 6681 Fax 626 855 4862 Web www whitehallmfg com Instructions for Operation and Care of Forma Splint Thermal Bath temperature limit and counterclockwise to lower the temperature limit Please note that 1 8 of a turn is approximately equal to 5 F 15 C DO NOT turn the thermostat more than one full turn in either direction Reinstall the nameplate and fill the unit
16. winklee Stainless Steel Cleaner Polish Penny Brite Cameo Stainless Steel Cleaner Polish and EZ Brite on stainless steel surfaces Strictly follow brand name manufacturer s instructions on proper use of the stainless steel cleaner NOTE The use of brand names is intended only to indicate a type of cleaner DO NOT use bleach chlorinated solvents or other harsh chemicals to clean your appliance DO NOT use steel wool to clean the stainless steel surfaces For scaly hard water spots use a strong solution of vinegar amp water and let it stand for approximately 5 minutes Rinse with clean warm water and wipe dry WHITEHALL SPLINT PANS Whitehall Part Description 6903 160 000 Drain Barb Stainless Steel 6903 112 199 Bottom Panel 2 6903 212 199 Bottom Panel EB 6903 152 000 Drain Ball Valve Stainless Steel 1 4 18 NPT x 1 4 1 4 18 NPT x 1 4 SP 1501 SP 1501B SP 1502 SP 1502B vf fet Phone 800 782 7706 626 968 6681 Fax 626 855 4862 Web www whitehallmfg com Instructions for Operation and Care of Forma Splint Thermal Bath L Lond Drain Threaded Pipe Stainless Steel 1 4 18 x 3 NPT eT rei 1 Drain Threaded Pipe Stainless Steel 1 4 18 x 5 NPT fr Fe ted lent TET K cl seni T T p x qee pe lO ppemepeem 0 R Face Plate Plastic for Control Panel rere tT 7 Face Plate Plastic for Control Panel BEEENMESES Dr ese ume 7 7
17. with 3 76mm of water During manufacturing the low temperature is preset at 160 F 71 C and the high temperature at 175 F 79 C On the standard SP 1502 model the temperature is varied by turning the thermostat knob clockwise for an increase and counterclockwise for a decrease in temperature The temperature on low setting should approximate 140 F 60 C and on high 190 F 88 C A WARNING Use the Splint Pan only as directed in this manual Any other use can cause injury USING YOUR SPLINT PAN Once the digital display indicates the desired temperature the appliance will be ready for use Allow 3 F 16 C temperature variance Always refer to the correct temperature amp duration specified by the splinting material manufacturer Be certain to heed all warnings as outlined in the WARNING section inside front cover of this manual Keep lid closed while water is heating up Carefully insert splinting material into tank and avoid splashing HOT water Avoid direct skin contact with HOT water at all times While splint material is immersed in water the lid should remain closed to help retain heat inside tank Remove splint material from tank only after it has reached the manufacturer s specified duration Use caution when removing splint material from tank Apply splint material as specified by splint manufacturer s instructions Keep the lid closed when appliance is not in use Maintain proper water leve