Home

Fitting and Operation of Villa intercom

image

Contents

1. At rest the lock mechanism keeps the door locked When the relay is activated by the relay card the current flows and the lock mechanism allows the door to open The power supplied to the electric lock mechanism must be less than 42 V AC or 60 V DC If the power supply voltage exceeds these values use an intermediate relay of the correct capacity to control the electric lock Installation of a varistor blue spot is essential for the relay to work properly This varistor is calibrated for 12v EN V233 5010 AA Fitting and Operation of Villa Intercom Page 9 15 C CABLING OF A DOOR FITTED WITH A MAGNETIC LOCK Wire the push button between the PB and GND terminals of the relay card When the button is pressed the relay card s relay cuts off power to the magnet for the amount of time programmed online If the central unit is not functioning the PB s NC contact will also cut off power to the magnet At rest power is supplied to the magnet and it keeps the door locked When the relay is activated by the central unit the magnet s power supply is cut the magnetic lock opens the door The power supplied to the electromagnet must be less than 42 V AC or 60 V DC If the power supply voltage exceeds these values use an intermediate relay of the correct capacity to control the electric lock Installation of a varistor blue spot is essential for the relay to work properly This varistor i
2. O C mE 000000000000000 OOOOOOGOOO0OOO0O00 OOOOO0O0000000000 OOOOOOOQGOOOOOOOO OOOO0OQ0O0O000000000 224 240 270 224 100 O Relay card External 3G antenna SS f longueur du cable 5 m 5 a S C te percer diam tre 18 EN V233 5010 AA Fitting and Operation of Villa Intercom Page 6 15 E MOUNTED TO A POST FIXING 245 1 Cut out a space for the box housing in the post 2 Drill 6 mm hole or tap M5 thread 3 Press the intercom into the housing 4 Screw it to the post Same procedure for mounting villa Intercom at 3 and 4 the following buttons Make sure cables are not pinched by the box They might get cut through when you tighten Remember to run the cable in a gooseneck shape as close as possible to the terminal EN V233 5010 AA Fitting and Operation of Villa Intercom Page 7 15 F MOUNTED TO A POST SIZE Intercom INTRATSNE OOOOOOGOOOOO0OOOO OOOOOOGOGOOOOOOOO OOOO0OOOOOOOOOOO OOOOO
3. MYINTRATONE COM 11 B PROGRAMMING PHONE NUMBERS WITHOUT GOING ONLINE 12 C CONFIGURATION ONLINE AT INTRATONE COM IN THE MANAGEMENT WEBSITE TAB 12 POST INSTALLATION CHECK 13 A TESTING THE CABLING OF THE RELAYS AND THE REMOTE CONTROLO MM 13 B CHECKING THE INTERCOM S SIGNAL RECEPTION STRENGTH 13 C CHECKING AUDIO AND VISIO CALLS WITH YOUR PHONE BEFORE THE INTERCOM IS IN SERVICE 13 TROUBLESHOOTING 14 A MOST COMMON PROBLEMS 14 B PROCEDURE TO RESET THE INTERCOM 14 CERTIFICATE OF CONFORMITY 15 EN V233 5010 AA Fitting and Operation of Villa Intercom Page 2 15 DIMENSIONS AND MOUNTING A SURFACE MOUNTED FIXING To use the wall plugs provided drill O 7 mm 1 Fix the mounting bracket 2 Hook the intercom onto the anchor points 3 olide and push the intercom flat 4 Screw Same procedure for mounting the villa Intercom 1 to 4 following buttons i r to close AND PUSH FLAT against the LLL OL SCREW ON the intercom A Make sure cables are not pinched by the box They might get cut through when you tighten Remember to run the cable in a gooseneck
4. for the intercom to recognise buttons 1 and 2 When you press the button Configure a number for the nothing happens programmed for this button button in question B PROCEDURE TO RESET THE INTERCOM You can reset the intercom in the event of a problem this will clear all the data and settings Only the remote controls will work after you reset Procedure to reset Remove the black plastic tab on the back of the intercom to access the reset button to the right of the green connector Press the button the backlit label goes out until it lights up again then release the button Press the button again until the label lights up gt Repeat this operation a third time The backlit label will flash twice and then you will see the intercom s GSM 3G signal strength again NOTE ANY PHONE NUMBERS THAT WERE NOT PROGRAMMED VIA THE WEBSITE WILL BE LOST IN THIS OPERATION EN V233 5010 AA Fitting and Operation of Villa Intercom Page 14 15 CERTIFICATE OF CONFORMITY V233 FITTING AND Operation OF VILLA Intercom AA Page 15 15
5. signal The LEDs blink The number of LEDs indicates the slowly strength of 3G signal reception The number of LEDs indicates the The LEDs emit a ciu double bini strength of GSM signal reception Visio calls impossible C CHECKING AUDIO AND VISIO CALLS WITH YOUR PHONE BEFORE THE INTERCOM IS IN SERVICE As long as no numbers have been programmed you can test calling your phone directly from the intercom To do this follow these steps gt Call the villa intercom from your cell phone without hiding your number the telephone number of the villa intercom is given in the End User s Manual Let it ring 2 or 3 times The villa intercom is ready when the white LEDs of the camera light up Hang up Now press the callbutton on the villa intercom or press any callbutton if you have a model with 2 3 or 4 buttons The villa intercom will call you in Visio if your phone does not have Visio the villa intercom will make another call in audio 30 seconds later You can answer and check straight away that the Visio feature is working Press a button on your phone to activate the sound Press 1 on your phone to activate relay 1 or press 2 to activate relay 2 YYY V V WV Note Your phone s User Manual will tell you if it has the Visio feature Before fastening the call panel carry out a test with a Visio phone so that you can easily determine the optimum height that will give the best visibility on phones of tha
6. FITTING AND OPERATION OF THE VILLA INTERCOM aN INTRAT NE d GENERAL POINTS The villa intercom is a pushbutton intercom with backlit labels that works with the GSM 3G network It can call both landlines and cell phones The entrance door can be opened in 3 ways From the phone that receives the intercom call With one of the 2 remote controls provided By calling the intercom Mobile Key function This intercom can control up to 2 entrances thanks to 2 NO NC type relays The 2 remote controls provided are pre programmed so you can check the cabling of your relays as soon as your installation is switched on To configure the numbers to be called log on to the following website with the phone number of your villa intercom http www myintratone com On the website you can also access the following features Configure new remote controls Seta code this feature is available with the villa intercom 1 callbutton 9 button keypad model Program time slots Set the volume of the intercom View log events calls remote controls codes etc Activate automatic answering no need to press O to speak Set time delay Add a new HF receiver managed by the intercom remote controls only compatible with INTRABOX ECO HF models If your intercom is in a residence where several Intratone products are in operation you can also register it on this website http www intratone com in the management websi
7. ONLINE The numbers to call from the intercom can also be programmed on site using the push buttons In order to do this you must have with you the phones you want to link to the system To program the numbers to call follow these steps Press down for 5 seconds on the call button to be programmed The LEDs at the bottom of the call panel will flash quickly indicating that it is in orogramming mode Call the villa intercom from the primary phone that your client wishes to use without hiding your number the villa intercom phone number is given in the End User s Manual Letit ring 2 or 3 times The villa intercom is set when the LEDs at the bottom of the call panel switch off Hang up gt The villa intercom is now programmed with your client s phone number and you can press the call button to make sure that it correctly makes the call Your client can answer and check straight away that it works in Visio or audio depending on the type of phone they have and the type of line Press any button on the phone to activate the sound Press 1 on your phone to activate relay 1 or press 2 to activate relay 2 C CONFIGURATION ONLINE AT INTRATONE COM IN THE MANAGEMENT WEBSITE TAB You can program your intercom on the website www intratone com in the management website tab This website lets you combine your management of the villa intercom equipment with products from the Intratone range To create your villa i
8. OOOCOO0OOOOO OOoGocOoOoOOOOOOOGO Relay card External 3G antenna 2A CN LH C f y p LL j f fa VAN i C A t EA percer diam tre 18 EN V233 5010 AA Fitting and Operation of Villa Intercom Page 8 15 CABLING A CABLING OF INTERCOM AND THE RELAY CARD Relay card operating g Intercom Antenna E V INTER 12 indicator Inside view 3G Fo A External TE BIAS G am gt AER M Cente SESE LL l ig A Drill the cabling Coaxial hole as small as rc e possible to avoid Antenna RN water ingress HF Banana nen 868 MHz optional Twisted pair cable 5 10 100 meters max Op LE Coaxial 50 ohms POWER SUPPLY As close as possible to the relay card 12 24 V AC DC 350 700 mA B CABLING OF AN ENTRANCE OR DOOR FITTED WITH AN ELECTRONIC LOCK MECHANISM Wire the push button between the PB and GND terminals of the relay card When the button is pressed the relay card s relay supplies power to the lock mechanism for the amount of time programmed online If the relay card is not functioning the PB s NO contact will also supply power to the lock mechanism ensure there is a backup power supply
9. he intercom Up to 10 numbers can be programmed for each button You can also designate whether the phone is Visio compatible or not and set time slots Add modify my remote controls This menu lets you configure the remote controls that give access This is also the menu where you can set your Mobile Key this feature allows you to give access via your phone Finally if you have the villa intercom 1 call button 9 button keypad model you can set your keypad codes here gt View log events This menu lets you view phone numbers called from the intercom the remote controls and Mobile Key as well as the codes entered if you have the villa intercom 1 callbutton 9 button keypad model gt Configure my advanced settings This menu lets you control several features Adjust the volume on the intercom handset Set the time lapse before the intercom hangs up after opening Set the password to access the website www myintratone com Email alerts Time delay for door opening Time ranges for the intercom the remote controls and the keypad codes Activate automatic answering no need to press O to speak gt My set up This menu lets you designate which entrances are controlled by the relays and you can also configure a HF 06 0101 EN kit if you want to add a HF receiver to your installation EN V233 5010 AA Fitting and Operation of Villa Intercom Page 11 15 B PROGRAMMING PHONE NUMBERS WITHOUT GOING
10. ntercom create a residence and register an entrance such as villa intercom by clicking on the button e Then you can program the numbers by clicking on configure opposite designate label s The remote controls provided with the equipment must be registered on the management website To do this you must create an authorisation and add the remote control in an apartment If you have a 1 callbutton 9 button keypad model you can add a code To do this click on codes to the right of the entrance you want to program NOTE The villa intercom that has been registered on the website intratone com can no longer be registered on the website www mvintratone com and vice versa EN V233 5010 AA Fitting and Operation of Villa Intercom Page 12 15 POST INSTALLATION CHECK Once your villa intercom is installed and switched on you can carry out different tests to check that it works A TESTING THE CABLING OF THE RELAYS AND THE REMOTE CONTROLS The remote controls provided with your villa intercom are already configured to work when the system is switched on Press 1 the button marked I on the remote control and see if the entrance linked to relay 1 opens correctly Do the same thing with button 2 the button marked Il if you have 2 entrances to control B CHECKING THE INTERCOM S SIGNAL RECEPTION STRENGTH When you turn the power supply to your intercom on for the first time the 5 LEDs at the bottom will eE the b of
11. s calibrated for 12v The alarm contact should be wired between the Alt and GND terminals of the central unit If the contact is triggered an email alert is sent I xm B kon after a pre programmed period of time has elapsed NC F The type of contact can be NO or NC All the alarm settings can be configured on the website www myintratone com in the menu Configure my advanced settings E CABLING THE ANTENNA If the intercom is fitted in an area with bad 3G reception you can connect the external 3G antenna provided with this kit e You do not have to use the external antenna It allows you to connect to the 3G network wherever reception is best 1 Remove the cable pass through 2 Flick the switch down Position with external antenna 3 Screw in the external antenna cable 4 Position the antenna high up 5 Test by making a call EN V233 5010 AA Fitting and Operation of Villa Intercom Page 10 15 EQUIPMENT CONFIGURA TION A CONFIGURING ON THE WEBSITE WWW MYINTRATONE COM Most of the programming for the villa intercom is done on the website www myintratone com To be able to configure your equipment you need to have your intercom s 10 digit telephone number he villa intercom telephone number is given in the End User s Manual The website myintratone com has 5 sections Add modify my phone numbers This menu allows you to enter the phone numbers to be called from t
12. shape as Close as possible to the terminal EN V233 5010 AA Fitting and Operation of Villa Intercom Page 3 15 B SURFACE MOUNTED SIZE Intercom ooooooOocoOoooOQO oooooocoooooooQ OOoOo0OOoOOoOOOOOOOOO OO0O000000000000 oO0oooocOooo0o0o0oocoOo o o 0 C N 129 s TILES leeee H a percer diam tre 18 AN R R T O D E EN V233 5010 AA Fitting and Operation of Villa Intercom Page 4 15 C FLUSH MOUNTED FIXING WHAT IT LOOKS LIKE ON THE WALL Press the casing 000000000000000 6900000000 cases e60000 1 Prepare the recess in the wall to receive the casing 2 Put the casing into the wall and Make sure cables are not fasten l pinched by the box 3 Push the intercom into the casing They might get cut and screw to fasten through when you tighten Same procedure for mounting the villa Intercom at 3 and 4 the following buttons o o Remember to run the cable in a gooseneck shape as close as possible to the terminal EN V233 5010 AA Fitting and Operation of Villa Intercom Page 5 15 D FLUSH MOUNTED SIZE l Intercom Casin is 84 K 84 _ 37
13. t tvpe EN V233 5010 AA Fitting and Operation of Villa Intercom Page 13 15 TROUBLESHOOTING A MOST COMMON PROBLEMS What is the fault ee How to fix the fault The LED on the relay card There is no power supply Check power supply to the does not come on to the relay card and terminals The LED on the relay card is Cabling problem between Check the cabling between permanently switched on the intercom and the relay terminals 3 and 4 of the relay card card and terminals 3 and 4 of the intercom The door does not open The relay is incorrectly Check the change of state when you press on the wired or the door control is between C and T on the relays remote control or when the faulty with an ohmmeter where there is a intercom says The door is bridge between the BP input 1 or open 2 and the ground Check the door control without the central unit simulate the relay with wires The LEDs on the intercom The intercom is searching Connect up or reposition the light up one by one for the GSM 3G network EEN ANTD EDGE antenna continuously but can t find it provided with your equipment in order to get a better signal When you press 1 or 2 on The intercom has not Check that the Voice the phone the intercom recognised the button you frequencies feature is activated does not say The door is pressed on the phone on the phone open You may need to press the button first in order
14. te tab Note that this action is irreversible and a villa intercom that has been registered on www intratone com cannot be registered on www myintratone com and vice versa EN V233 5010 AA Fitting and Operation of Villa Intercom Page 1 15 CONTENTS GENERAL POINTS 1 CONTENTS onu 2 DIMENSIONS AND MOUNTING 3 A SURFACE MOUNTED FIXING 3 B SURFACE MOUNTED CLEARANCE 4 C FLUSH MOUNTED FIXING 9 D FLUSH MOUNTED CLEARANCE 6 E MOUNTED TO A POST FIXING 7 F MOUNTED TOA POST CLEARANCE 8 CABLING 9 A CABLING OF INTERCOM AND THE RELAY CARD 9 B CABLING OF AN ENTRANCE OR DOOR FITTED WITH AN ELECTRONIC LOCK MECHANISM 9 C CABLING OF A DOOR FITTED WITH A MAGNETIC LOCK 10 D ALARM INPUT CABLING 10 E CABLING THE ANTENNA 10 EQUIPMENT CONFIGURATION 11 A CONFIGURING ON THE WEBSITE WWW

Download Pdf Manuals

image

Related Search

Related Contents

QUPiO 万歩計(YAMASA・TH-850)  SW-24X / 25X AM0 USER MANUAL  ViewSonic VS12119-1M User's Manual  Mode d`emploi Daikin Altherma bi bloc basse temperature ECS  EdgeStar EAC211TS User's Manual  16053 WG OM EK/EE  Samsung WD8754RJA 用户手册  Please read this owner`s Manual carefully before operating the unit.  23 木目調樹脂デッキ(1.5坪)組立説明書  Here - Terasic  

Copyright © All rights reserved.
Failed to retrieve file