Home

2 WIRE INTERCOM SYSTEM

image

Contents

1. not be deleted on monitor directly 7 Staircase Light Note the staircase light function will be activated only when the system connect light via SC6M module otherwise this function is unvalid in normal For more information please refer to SC6M user instruction in detail On main menu page or in monitoring touch Light icon to open the staircase light the staircase light will be turned off automatically 8 Basic Setup Instructions Ring Tone Settings Touch User Setup item on main menu page to enter setup page Touch Door Station Call Tone Inercom Call Tone or DoorBell Tone item There are 12 pieces ring tones can be selected touch a ring tone you want then touch icon to save the setting and exit touch icon to cancel the setting and return last page Door Station Call Tone set the ring tone calling from outdoor station Intercom Tone set the ring tone calling from other apartments DoorBell tone set the ring tone calling from door bell Carmen Going Home Ding Dong Congratulate a Rhythm of the rain DoReMe For Elise Happy Birthday Sonatine Jingle Bell M Edelweiss lt Telephone Ring Ring Volume and Night Ring Volume Setting You can set a ring volume for day time and night time individually 6 00 AM 18 00 PM is the day time and 18 00 PM 6 00 AM is the night time by default if you don t want to be disturbed at night you can set the night ring volume to 0 Touch User Setup item on main me
2. the organic impregnant or chemical clean agent If necessary please use a little pure water or dilute soap water to clean the dust 3 Image distortion may occur if the video monitor is mounted too close to magnetic field e g Microwaves TV computer etc 4 Please keep away the monitor from wet high temperature dust caustic and oxidation gas in order to avoid any unpredictable damage 5 Must use the right adaptor which is supplied by the manufacturer or approved by the manufacturer 6 Pay attention to the high voltage inside the products please refer service only to a trained and qualified professional DT ENG 47TD7 V 1 The design and specifications can be changed without notice to the user Right to interpret and copyright of this manual are preserved
3. to set the unlock mode to 1 Unlock time The unlock time can be changed by yourself at any time it can be set from to 9 seconds The code number from 8021 to 8029 are used to set the unlock time to 1 9 seconds How to set the user code for the monitor Each monitor should be assigned an address in the system total 32 addresses can be configured the code number of 8200 to 8231 is used to controlled the address of 00 to 31 Please refer to the following table 8200 Code 0 8211 Code 11 8222 Code 22 8201 Code 1 8212 Code 12 8223 Code 23 8202 Code 2 8213 Code 13 8224 Code 24 8203 Code 3 8214 Code 14 8225 Code 25 8204 Code 4 8215 Code 15 8226 Code 26 8205 Code 5 8216 Code 16 8227 Code 27 8206 Code 6 8217 Code 17 8228 Code 28 8207 Code 7 8218 Code 18 8229 Code 29 8208 Code 8 8219 Code 19 8230 Code 30 8209 Code 9 8220 Code 20 8231 Code 31 8210 Code 10 8221 Code 21 10 Specification e Power supply for indoor monitor DC 24V e Power consumption Standby 28 3mA Working 302mA e Monitor screen 7 Inch digital color LCD e Display Resolutions 800 3 R G B x 480 pixels e Video signal 1Vp p 75 Q CCIR standard e Wiring 2 wires non polarity e Dimension 131 H xX 225 W x 18 D mm 11 Precautions 1 All components should be protected from violence vibration And not allow to be impacted knocked and dropped 2 Please do the cleanness with soft cotton cloth please do not use
4. ENGLISH 2 WIRE INTERCOM SYSTEM USER MANUAL Please read this manual carefully before using the product and keep it well DT ENG 47TD7 V1 1 Parts and Functions Digital TFT LCD Screen UNLOCK Button TALK MON Button e Microphone N S D Mounting Hook an m e Speaker Connection Port O K 5 Mounting Hook Z 6 OJ Key functions n mae Unlock button Press to release the door Talk Mon button Press to communicate hands free with visitor Press to view the outdoor condition in standby mode Send out vioce from the visitor 2 Monitor Mounting 145 160 cm oe 0 6 6 6 gt Pe SOE SEE SOY SOE SO OE OE OEE SE OE OF Oo Oe Oo OF Oo ot Ge OEE SO SOY SOE OE OEE SEE SE SOE e SO SO SO OE OE SE SE SE OE E E Sr SO SO SO SO a SO Se 1 Use the screws to fix the Mounting Bracket on the mounting box fitting accesories includes a Bracket Two pieces of 4X25 screws are needed for fastening the Mounting Bracket Special 2 wire connectors to connect with Monitor 2 Wire the system correctly see the later connection chapter then hang the Monitor on the Mounting Bracket firmly 3 Main Menu Touch the screen anywhere on monitor in standby mode the main menu page N oO will be shown as follows EUEN Monitor Intercom M
5. e image quality setting adjust the value to get the best image you like 3 The Talk Volume item is for talking volume adjustment 4 Note that all the modifications will be performed immediately after the operation Touch icon to exit the adjust page Restore to Default The restore to default function allows the user to recover the settings to factory setting Note that the restore to default operation will not change the setting and datas Enter main menu page then touch User Setup icon to enter the setting page press Restore to default item the default settings will be loaded press Home icon to return to home screen page 9 Monitor Parameter Setting How to enter the installation setting page 1 Touch icon 2 Touch C UNLOCK 3 A digital keypad on main menu page button and hold for 2s will be shown How to set the monitor as a Guard Monitor A Monitor can be assigned as Guard Unit Monitor when the Guard Unit Monitor answers the call conversation with the guard person 1s started The code number of 8004 is used to set the monitor as a guard unit monitor and 8005 is used to cancel this function How to set the slave monitor address Maximum 4 monitors can be connected in one apartment one master monitor together with 3 slave monitors so you should set the address correctly note must have one monitor to be set as master monitor The code of 8000 is used to set the master monitor The code of 8001 is used to s
6. emor Monitor Playbac E LS User Setup About Be 4 Basic Door Release Operation 1 Press CALL button on outdoor station the Monitor rings at the same time the screen displays the visitors image 2 Press TALK MON Button on monitor or touch icon on screen you can communicate hands free with the visitor for 90 seconds After finishing communication press TALK MON button again or touch icon to end the communication If nobody answers the phone the screen will be turned off automatically after 30 seconds 3 During talking state Press J UNLOCK Button or touch icon to open the door for the visitor if two locks are connected to door camera touch unlock 2nd icon to release the second lock 4 When the monitor is in standby mode press TALK MON Button or touch Monitor item on main menu page The screen can display the view of outside Or touch Manual Monitor icon on main menu to get into the door camera switching mode if multi door stations are installed you can press the door 1 2 3 4 to monitor the door station or CCTV camera you want press Home icon to exit and enter main menu page About fi Home Note if the system connect 2 wire camera via camera controller press the camera 1 2 3 4 to monitor the camera you want press Home icon to exit and enter main menu page 6 Intercom Function Intercom by namelist User in one apartment can call other apartments
7. et the first slave monitor The code of 8002 is used to set the second slave monitor The code of 8003 is used to set the third slave monitor Note touch button to cancel the input touch to save the settings How to set date and time format The system offers two methods of date and time The code number of 8008 is used to set the date format as month date year The code number of 8009 is used to set the date format as date month year The code number of 8012 is used to set the time format as 12 hour system The code number of 8013 is used to set the time format as 24 hour system How to set the monitor panel on In default mode when receive a calling the master and slave monitors will ring at the same time and just the master monitor can display the image while the slave monitors can not But the settings can be changed you can set the master monitor and all the slave monitors to panel on at the same time when receiving a call just input the code number of 8006 on each slave monitor Press call button on door station When reveiving calling all monitors can display the image at the same time Master monitor 1st slave monitor 2nd slave monitor 3rd slave monitor 9 How to set the unlock parameter Unlock mode There are two unlock modes 1 power on to unlock type unlock mode 0 by default 2 power off to unlock unlock mode 1 The code number of 8010 is used to set the unlock mode to 0 The code number of 8011 is used
8. in the system Touch Intercom item on main menu page then touch Intercom by Namelist icon the namelist will be created automatically by the system Select a name on the screen then touch Dial Number icon to call Press enter last next name list page Touch K Dial Number icon again to redial icon to Inner Call If multi slave monitors are installed in the same apartment select Inner Call all the other Monitors will ring at the same time whichever Monitor answers the call conversation is started and the other monitors will stop ringing at the same time Direct Dial Guard unit A Monitor can be assigned as Guard Unit Monitor when the Guard Unit Monitor answers the call conversation with the guard person is started Picture Memory Note the picture memory function will be activated only when the system connect SC6M module otherwise this function is unvalid in normal For more information please refer to SC6M user instruction in detail Picture Recording Both Auto Recording and Manual Recording are available and Auto Recording is default If receive a call after 3s the monitor will record one picture for each calling automatically Or you can touch Capture icon to record the visitor s image manually when the monitor is in monitoring or calling _4 5 Picture Playback Touch Memory Playback icon on main menu the recorded pictures will be played on full screen please note that the recorded pictures can
9. nu page to enter setup page then touch Ring Volume or Night Ring Volume item then touch wo icon to increase decrease the value After finish touch HA icon to save and exit touch icon to cancel the setting and return last page Date and Time set Touch User Setup item on main menu page to enter setup page then touch Clock item input digitals by pressing the digital keypad Y gt Year M gt month D gt Date W gt week H gt Hour M gt Minute S gt Second Press icon to cancel the setting location and press icon to save Settings will be performed immediately press icon to return last page Note the date and time setting is valid only when the system connect SC6M module Monitor Time settig Touch User Setup item on main menu page to enter setup page then touch Monitor Time icon to enter monitor time setting page Input digitals by pressing the digital keypad setting range is 6 600 press icon to cancel the setting location and press icon to save Settings will be performed immediately press icon to return last page 4 Screen and Volume Adjustment During monitoring or talking state touch Adjust icon the Adjust page will be displayed 1 The Scene mode selection Total 4 screen modes can be selected in sequence Normal User Soft and Bright Whenever you modify Brightness or colour Scene item will be set to User mode automatically 2 The Brightness item is for th

Download Pdf Manuals

image

Related Search

Related Contents

Home Entertainment Guide 03 - 04 part 2  [MI 611-226] Remote Communications Program for 875  Samsung SGH-B500 Felhasználói kézikönyv  

Copyright © All rights reserved.