1. Step 2 When the device prompts Thank you as shown in Figure it indicates that the authentication is complete PIN Name Mike P Identification successful O Identification failed Figure Figure When the device prompts Please try again as shown in Figure it indicates that the authentication is failed 2 1 1 fingerprint authentication PIN plus fingerprint Compare the current fingerprint read by the finger sensor with the fingerprints associated with the user number that is entered through the keyboard Step 1 Enter the PIN of the person to be authenticated on the initial interface through the keyboard as shown in the right figure Step 2 Have the fingerprint read by the finger sensor correctly Step 3 When the device prompts Thank you it indicates that the authentication is complete When the device prompts Please try again it indicates that the authentication is failed The device allows the user to retry twice If two retries fail it returns to the initial interface Password Attendance Step 1 Enter the PIN of the person to be authenticated on the initial interface through the keyboard and press the ENTER key 1 Usage Instructions Step 2 When the device displays the authentication interface as shown in Figure it indicates that the PIN is invalid or the employee with the PIN does not register his her password U Please scan your finger O Please input password F
2. On the initial interface of the attendance system you are authenticated through your fingerprint password or card If you pass the authentication the device keeps your attendance records 1 4 1 Initial Interface Please scan your finger 02 16 2011 Ea oe ACTI a Search AbtLog Current time of the system The time is refreshed in real time WorkState Check In by default When you click the Check In Check Out or Break Out button the workstate is switched accordingly You can also press keys Fl to F4 to switch the workstate Keys F1 to F4 correspond to Check In Check Out Break Out and Break In respectively You can click the key to enter the main interface for User Manager system set and USB disk management Search AttLog You can query the attendance records of a certain employee in a specific period by entering his her PIN end date and begin date User Manual for P101 Attendance system 1 4 2 Employee authentication Modes On the initial interface you can directly be authenticated by your card password or fingerprint 1 1 and 1 N If you pass the authentication the device automatically saves the attendance record and returns to the initial interface o Fingerprint Attendance 1 1 N fingerprint authentication Compare the current fingerprint read by the fingerprint read with all fingerprint data stored in the device Step 1 Have the fingerprint read by the finger sensor correctly
3. A O teee ea iteee tai takebe steer tanetnectalal 18 ALO POWER MIAN AGL ving 2 ac to tidota ii 18 FORECO A ee was PO nn 19 GD Ay WONG Savi AA e PP re O II IA 19 TENES A A ici scab aseckysacsancecasea ean ae Se HOO 20 SUSB Disk Mana A a 2l AN AAA E E A 21 8 1 1 Download Attendance Data iiaii a a S 21 01 2 Download User Dita ss 21 2 Uploadino Data lis desd as A os de dd dd 22 Ss en en HE A 22 A nee E 23 User Manual for P101 Attendance System Appendix 1 T9 input Method ssis 23 Appendix 2 Keyboard Descripti0N cccooooooncccnnncnnnononcnonnnnnnnonnnnnnnonononanononnss 25 Appendix 3 Statement on Human Rights and PriVacy oooooooccncnnncnnnnnncnnnnss 26 Appendix 4 Environment Friendly Use Description ccccoooooocccononcnnnnonononos 21 I 1 Usage Instructions 1 Usage Instructions 1 1 Recommended Usage Procedure Step 1 Power on the device Step 2 Register a user including the fingerprint password or card and assign authorities to the user Step 3 Authenticate the user and check whether the registered fingerprint password or card 1s available Step 4 Check whether the device time is accurate If yes the device can record the attendance Step 5 At the end of each month download the attendance records for query card re signature and statistics reporting 1 2 Use of Touch Screen Touch the screen with one of your fingertips or the top of the forward edge of a fingernail as shown in the followin
4. the employee is found the system automatically places the blue cursor to the employee If the employee is not available the system returns to the user list 12 3 User Manager 3 2 2 Search Attendance Record When querying the registered information for example fingerprints of an employee the administrator can query the employee s attendance records of the current month On the Management User interface press the a and w keys or use Search User to locate the blue cursor at the user to be queried Click Search Attendance Record in the pull down list and then query the selected employee s attendance records of the current month Press the and w key to view the attendance records line by line View the details by pulling the sliding bar at the lower part or on the right side of the window Search Attendance Recon PIN Name BrushTime 1 1 1601 12 1 Ce ee 1 1 1601 12 1 Search Attendance Record 1 1 1601 12 1 1 1 1601 12 1 1 1 1601 12 1 1 1 1601 12 1 1 1 1601 12 1 1 1 1601 12 11 1 1 1601 12 1 1 1 1601 12 1 1 1 1601 12 11 1 1 1601 12 11 1 1 1601 12 11 1 1 1601 12 1 1 1 1601 12 11 gt Click the X key on the screen or press the ESC key to return to the Management User interface A NVNNNNNNNNNNNND WY 3 2 3 Edit User You can modify the user information stored in the device For example a registered fingerprint is unavailable and you need to register fi
5. the WorkState Automatic Transfer in a week the system checks whether the workstate needs to be switched by minutes When the user saves the settings the saving operation of the same day or same time does not take effect 20 8 USB Disk Management 8 USB Disk Management You can use a USB disk to import the user information fingerprint template and attendance data saved in the device to the auxiliary attendance recording software or export the user information and fingerprints to another attendance recording device Usb Disk Management x at 8 1 Download Date 8 1 1 Download Attendance Data You can save all attendance data in the device to a USB disk Operating instructions l Insert a USB disk to the USB slot of the device through a USB cable 2 Click Download the Attendance Data The device prompts Downloading data and please wait till the device prompts Download succeeded 3 Press OK to return to the data download interface and remove the USB disk In the USB disk the attendance records are saved in the X_attlog dat directory X stands for the device ID 8 1 2 Download User Data Save all user information and fingerprints in the device to a USB disk Operating instructions Insert a USB disk to the USB slot of the device and select Download User Data After user data is downloaded successfully you can see the user dat file and template dat file in the USB disk 21 User Manual for P101 Attendance sys
6. User Manual for P101 Attendance system Document Version 1 0 Firmware version 1 0 Date Jan 2011 About This Manual This document introduces the user interface and menu operations of the P101 attendance system User Manual for P101 Attendance System Contents MI SACS is AMA E EA l 1 1 Recommended Usage Procedure 0er dia l PA Touch Serce A oe ain eas E oe aa eee l ko Tiner Placa 2 E AboutAttendance A E E E O A A E 3 TAr Tina Ma oe FAC eas conse a eesones renin esterase toeresae ed 3 1 4 2 Employee authentication Modes cccccccccseecceeeeeeecceeaeeeeeeeeaes 4 Nai A O A O 6 A RR NR REND aN en ae ee EEE 7 JUser Manaos 8 O Gace Sansa ae pet EOE OON OE 9 Dole perineal Set PIN atte o sine ene atic 10 AA AA chelate sects ca lies ics RRA 10 Sle SRC OISESTING a Gai A leiced S 10 31 4 Registering the Finer pri mts spot did diia 10 A US A A 11 LO OC TG WONG ios les do dd o a ainda 11 22 a USER AAA Ris tittle sot tie thn acne d they 12 De ES Alec NY Se E cect stan Neat Nat ose A aucatauauan niaaewemsesouen ans 12 3 2 2 Deakch Attendance Roc 13 SOE DD E E E N E E 13 De AG Ite Sei anaa a a nab aeahaue aeabane re uaeaaeeeuanelx 14 A SER A a tend os seas EE E EE 14 AE TS VS CSIR DE AA A uaa salad wash ead ede tomea tear 15 ADAM acresactecestaaret E A EE 15 4 2 Regional Settings oosa an a a a fe eer tO N 15 AS NO iio 16 AAC abran CL a e EPA ts vb ayad e s a aa 16 4 5 Data Manaos tido 17 AOL UD A la 17 rn
7. attendance data saved in the device to the related software or import the user information to another fingerprint device System information Query the storage information and version information of the current device Power Manager Set the power supply scheme and timing sleep parameters of the device User Manual for P101 Attendance system 3 User Manager The basic information about users includes fingerprints passwords and management authorities If personnel changes occur to an employee the related information on the system should be changed accordingly Therefore the system allows you to add delete query and modify the user information On the main menu click User Manager to enter the User Manager interface User Manager Add User Management User 3 User Manager 3 1 Add user Register the fingerprint password or card number of an employee with the device The device supports a maximum of 3 000 users 1 500 fingerprints and 100 000 attendance records Enter the Add User interface PIN Name Card PWD Right 8 Normal User O Administrator PIN Attendance recording ID of an employee The system automatically generates PINs each PIN comprises one to nine digits by default and the maximum PIN is 999 999 999 Name Name of an employee each name comprises 12 digits by default You can press the F9 key in the keyboard to enable the T9 input method For details refer to Appendix 1 T9 input
8. ccessfully the device displays the P screen indicating that the password has set 3 1 6 Setting the Right Directly click the Normal user or administrator to be set in the selection box Save Exit the new user Check whether the registered information is correct Click the OK key to save the information and return to the upper level menu or click the Cancel key or press the ESC key on the keyboard to cancel the information and return to the upper level menu 11 User Manual for P101 Attendance system 3 2 Management User Through Management User you can query the information about all users saved in the current device including user names number of fingerprints whether register the passwords or cards and attendance records You can also edit or delete a user User List x User List x Search Attendance Record 2159846732 Edit User Delete User 1866622894 Add User The above interface displays users PINs names card numbers fingerprints and passwords Click the Pull down key Then the Pull down list displays five operation menu options Search User Search Attendance Record Edit User Delete User and Add User Click the desired menu options 3 2 1 Search User If there are a large number of registered users the device allows the administrator to locate an employee quickly through PIN and Name Search User x Enter the PIN or name of the employee to be queried and click the OK key If
9. ce enter the user name to be registered and click the Enter key to save it For detailed operations of the T9 input method refer to Appendix 1 3 1 3 Registering a Card Swipe the card in the sensing area until the card number is read by the device successfully The registered numbers are displayed in the text box PIN Name Mary Card 2159915036 Finger sey Count 0 PWD Right 8 Normal User O Administrator Note The card sensing area is in the area around the finger sensor 3 1 4 Registering the Fingerprints Click the Finger button to register fingerprints T Please scan your finger 10 3 User Manager Place the same finger on the fingerprint sensor for three consecutive times correctly Then the system gives the prompt information To register your fingerprints continuously press the key by another finger After the registration is complete click the Cancel key or press ESC key on the keyboard to return to the previous interface The device displays the current number of registered fingerprints 3 1 5 Registering a PWD Click the PWD button to register password A password comprises one to eight digits Enroll Password x Input Password eK E HE OK Confirm Password Enter a password as instructed Move the cursor to the Confirm Password input box and enter the password again to confirm it Click OK to save it or click Cancel to cancel it After you save the password su
10. ck is switched backward again The provisions about the Daylight Saving Time vary in different countries The device supports the Daylight Saving Time function At a specified time you can switch the clock forward by one hour At another specified time you can switch the clock backward to the standard time Daylight Saying Time Xx Month Day Hour Minute i 19 User Manual for P101 Attendance system Note If the begin month of the Daylight Saving Time is larger than the end month of the Daylight Saving Time it indicates that the Daylight Saving Time spans two years For example the begin time is 4 00 of 2007 9 1 and the end time is 4 00 of 2008 4 1 7 WorkState Automatic Transfer The system supports six work states Check in Check out Break out Return Overtime Start and Overtime Checkout The workstate needs to be modified manually that is you can switch to the desired work state by pressing the corresponding button To decrease the manual operations the device menu provides a WorkState Automatic Transfer option At the time specified by a user the device automatically switches the workstate The current workstate is displayed on the initial interface WorkState Automatic Transfer X Details Of Settings x a 44 Y Check In Sunday Monday 7 Check Out Tuesday Wednesday 7 Break in Thursday Friday Saturday Hour 7 Overtime Start _ Overtime CheckOut 4 z 5 l T After the user sets
11. el Editor Input symbols NumbersiEnzlish Transfers Take an example for the T9 English input Input John Step 1 Press the F key to enter the panel about the T9 input method and then press the keys 0 9 to switch between numbers and English Select English Step 2 Click the key 5JKL that have the letters J Then the text box displays the available english letters as shown in Figure If finding the desired letter J on the screen click it directly as shown in Figure Y If you enter an incorrect letter click the Clear key to clear it 23 User Manual for P101 Attendance system Figure Figure Step 3 To continue select letters repeat the above steps Click Enter to save the selected English characters or click ESC to cancel the selected characters and exit the T9 input method Input Panel Editor x 24 Appendix Appendix 2 Keyboard Description The functions of the keyboard vary on different interfaces as described in the following table Ke q Ein papin Number Natera 0 to 9 Input employees PINs and passwords ec 2 Modify the value of the current item E 2 Modify the value of the current item oe 2 Modify the value of the current item stem 2 Modify the value of the current item Power key Press and hold the key for three seconds to power on off the device Backspace key When inputting an incorrect PIN password or eo tee value pre
12. g figure A broad point of contact may lead to inaccurate pointing X A When the touch screen is less sensitive to the touch you can perform screen calibration through menu operations Press Menu System Set Calibration Screen on the screen and a cross icon will be displayed After you touch the center of the cross at five locations on the screen correctly the system automatically returns to the main menu Press Return to return to the initial interface For details see 4 4 Calibration Screen in this manual Smear or dust on the touch screen may affect the performance of the touch screen Therefore try to keep the screen clean and dust free User Manual for P101 Attendance system 1 3 Finger Placement Recommended fingers The index finger middle finger or the ring finger the thumb and little finger are not recommended because they are usually clumsy on the fingerprint collection screen 1 Proper finger placement The finger is flat to the surface and centered in fingered guide 2 Improper finger placement Not flat to the surface Off center Off center the degradation in verification performance due to improper user operations G mode We shall not be held accountable for any consequences arising out of We shall reserve the right of final interpretation and revision of this document mmm ee ee ee i ea ei ei ei i i i i i ei ei i i ei i i i ee 1 Usage Instructions 1 4 About Attendance
13. gement Xx Delete Attendance Record Click the options to be operated The device prompts whether you want to continue the current operation Click Yes or press ENTER to delete the data The deleted data 1s irrecoverable Click No or press ESC to exit the current operation and return to the Data Management interface 4 6 Firmware Upgrade The firmware of the device can be upgraded through the upgrade file saved in a USB disk Note If you need the upgrade file contact the technical support personnel Usually 1t 1s not recommended that you upgrade the firmware Operating instructions 17 User Manual for P101 Attendance system Insert the USB disk to the USB disk slot Click Firmware Upgrade Then the system decompresses the upgrade file package in the USB disk to the firmware directory The device automatically identifies the upgrade files and upgrades the firmware If the upgrade succeeds or fails the system gives the corresponding prompt After the system is restarted the upgrade takes effect 4 7 Calibrate finger sensor After the firmware is used for a period you may need to initialize the finger sensor regularly Click the button to implement the function 4 8 Power Manager Set the power supply scheme and timing sleep parameters of the device Power supply scheme The device supports to use the battery and AC power Switch state to User Idle This parameter 1s used to specify a period after which t
14. he device is put in user idle if no operation within this period The screen will be dimmed You can wake up the device by pressing any key except the power key or touching the screen or pressing your finger on the finger sensor or swiping the card Switch state to System Idle This parameter is used to specify a period after which the device is put in system idle if no operation within this period The screen will be dark You can wake up the device by pressing any key except the power key or touching the screen or pressing your finger on the finger sensor or swiping the card Power Manager Xx Power Scheme Battery Power y Switch state to User Idle fter 1 minute Switch state to System Idle after 4 minutes y 18 5 Search Record 5 Search Record The administrator can query the attendance records of a certain employee in a specific period by entering his her PIN end date and begin date Search Record xX Begin Date 10 1 2000 End Date 6 Daylight Saving Time Daylight Saving Time is an artificial local time that aims to reduce energy consumption During the implementation period the unified time is called Daylight Saving Time Usually in the summer during which the sun rises early the clock is artificially switched forward by one hour so that local people get up and go to bed early thus decreasing the electricity consumption for lighting and make the best of sunshine resources In the autumn the clo
15. igure Figure Step 3 If the device displays the interface as shown in Figure input the password Step 4 When the device prompts Thank you it indicates that the authentication is complete When the device prompts Incorrect password it indicates that the authentication is failed o Card Attendance Compare the current card number sensed in the sensing area with all card numbers registered in the device Step 1 Swipe the card in the sensing area and then move the card if the card is sensed successfully Step 2 When the device prompts Thank you it indicates that the authentication is complete Step 3 If the device shows Identification failed it indicates that the card is not registered PIN P Identification successful O Identification failed Note The card sensing area is around the finger sensor User Manual for P101 Attendance system 1 5 About the Document l Because the product is constantly updated the company does not warrant that the actual product is consistent with the document nor is liable for the dispute arising from discrepancy between actual technical parameters and the document The document is subject to change without prior notification The functions of keys vary with the device model For details refer to Appendix 2 Keyboard Description For detailed operations about the input mode refer to Appendix 1 T9 input method All keys in the physical keyboard herein are
16. ime samples 00 03 56 Time Style HH mm ss y Click the OK key to save the edited information and return to the System Set interface or click the Cancel key or press the ESC key on the keyboard to cancel the edited information and return to the System Set interface 4 3 Volume On the interface you can enable disable the voice prompt function and change the sound volume of the system Yolume Control x Click the OK key to save the edited information and return to the System Set interface or click the Cancel key or press the ESC key on the keyboard to cancel the edited information and return to the System Set interface 4 4 Calibration Screen The device can be operated through a touch screen You can directly operate a screen menu by hands or touch screen pen directly If the touch screen does not respond sensitively enter the System Set interface to calibrate the screen 16 4 System Set ess and briefly hold stylus on the center of peat as the target moves around the scree Press the Esc key to cancel Calibrate the touch screen as instructed Press the ENTER key on the keyboard to end the new settings or press the ESC key on the keyboard to reserve the original settings 4 5 Data Management Delete Attendance Record Delete all attendance records Delete All Data Delete all registered employee information fingerprints passwords and attendance records Data Mana
17. infringement of your privacy please contact the government or the final equipment provider We as the original equipment manufacturer shall not be held legally accountable for any infringement arising thereof The law of the People s Republic of China has the following regulations regarding the personal freedom 1 Unlawful arrest detention or search of citizens of the People s Republic of China is prohibited infringement of individual privacy is prohibited 2 The personal dignity of citizens of the People s Republic of China is inviolable 3 The home of citizens of the People s Republic of China is inviolable 4 The freedom and privacy of correspondence of citizens of the People s Republic of China are protected by law At last we stress once again that biometrics as an advanced recognition technology will be applied in a lot of sectors including e commerce banking insurance and legal affairs Every year people around the globe suffer from great loss due to the insecurity of passwords The biometric products actually provide adequate protection for your identity under a high security environment 26 Appendix e The Environment Friendly Use Period EFUP marked on this product refers to the safety period of time in which the product is used under the conditions specified in the product instructions without leakage of noxious and harmful substances e The EFUP of this product does not cover the consumable parts that need
18. lick the Cancel key or press the ESC key on the keyboard to return to the Management User interface 3 2 5 Add User To help the administrator to add users conveniently the device also provides the Add User option The operations of the option are the same as those described in section 3 1 Add User 14 4 System Set 4 System Set Set the system parameters correctly so that the functions and display of the device cater to users needs maximally System Set x 14 Date Time Regional Settings Calibration Screen La Data Management Firmware Upgrade Calibrate Finger Sensor 4 1 Date Time To ensure the accuracy of the recorded attendance you must set the time and date of the device correctly Enter the Date Time interface Date Time Properties x Date 2011 2 0 4 v Hour Minute After setting the information click OK to save the setting and return to the previous interface or click Cancel or press ESC on the keyboard to cancel the setting and return to the previous interface 4 2 Regional Settings Date samples Set the date format displayed on the initial interface The system supports nine date formats You can select a desired date format Time samples Set the time format displayed on the initial interface The system supports four time formats You can select a desired time format 15 User Manual for P101 Attendance system Date samples 01 01 1601 Date Style T
19. marked by Press the F key in the keyboard to enable disable the T9 input method All keys in the touch screen here are marked by For example click the Enter key on the input panel to save data 2 Main Menu 2 Main Menu On the initial interface click Menu to open the main menu as shown below System Set Xx a L 14 A Date Time Regional Settings volume Calibration Screen La Data Management Firmware Upgrade Calibrate Finger Sensor Power Manager User Manager Browse the employee information including the PINs names fingerprints cards passwords and authorities add edit or delete basic information about the employees and query the users and attendance records System Set Set the related system parameters including date time area sound volume and touch screen and perform data management so that the functions and display of the device cater to actual needs maximally Search Record The function allows an employee to query the attendance records saved in the device Daylight Saving Time In a specific period you can switch the system time forward by one hour and switch the system time backward to the standard time in another specific period WorkState Automatic Transfer At the time specified by a user the device automatically switches the workstate The current workstate is displayed on the initial interface USB Disk Management Use a USB disk to import the user information and
20. method card ID of the registered employee s card After an employee registers his her card the device can record his her attendance by the card Finger Fingerprint of a registered employee The device can display the number of registered fingerprints One user can register a maximum of ten fingerprints After an employee registers his her fingerprint data the device can record his her attendance by the fingerprints PWD Password of a registered user A password comprises one to eight valid digits After an employee registers his her password the device can record his her attendance by the password Right The system assigns a user the right about menu operations An normal user can only use his her fingerprints or card for recording the attendance In addition to daily attendance recording the administrator also has the right of menu operations Note If no administrator is set any user can perform menu operations After an administrator is set only the administrator has the right of menu operations User Manual for P101 Attendance system 3 1 1 Entering a User PIN 1 APIN is allocated by the system by default 2 You can delete the default PIN by pressing the lt key in the keyboard If entered an incorrect PIN from the keyboard you can press the key to input a correct PIN again 3 1 2 Entering a Name The F key in the keyboard is used to enable disable the T9 input method On the input panel interfa
21. ngerprints again or register a password and card enter the Edit User interface On the Management User interface press the a and w keys or use Search User to select the employee to be edited Select Edit User in the pull down list and then the system displays the registered information of the user PIN Name Mike Card 2159846732 mo E Right 8 Normal User O Administrator 13 User Manual for P101 Attendance system The PIN is not modifiable Other operations are similar to those for Add User You can register fingerprints or cards again If no password is available or the password needs to be changed click PWD The user s authorities can be modified Click the OK key to save the edited information and return to the Manage User interface or click the Cancel key or press the ESC key on the keyboard to cancel the edited information and return to the Manage User interface 3 2 4 Delete User You can select the Delete User option to delete all or some information of an employee from the device On the Manage User interface press the and w keys or use Search User to locate the blue cursor at the user to be edited Click the pull down key On the displayed operation menu select Delete User Delete User Xx PIN 2 Delete User Delete Password Click the desired operation option If the user has no name fingerprint or password the corresponding items are not operable C
22. ss the key to delete the incorrect value AA Moe the cursor to the last row of the current column AA Standby Standby a Enable disable the T9 input method 25 User Manual for P101 Attendance system Appendix 3 Statement on Human Rights and Privacy Dear Customers Thank you for choosing the hybrid biometric products designed and manufactured by us As a world renowned provider of biometric technologies and services we pay much attention to the compliance with the laws related to human rights and privacy in every country while constantly performing research and development We hereby make the following statements 1 All of our biometric recognition devices for civil use only collect the characteristic points of biometric instead of the biometric images and therefore no privacy issues are involved 2 The characteristic points of biometric collected by our products cannot be used to restore the original biometric images and therefore no privacy issues are involved 3 We as the equipment provider shall not be held legally accountable directly or indirectly for any consequences arising due to the use of our products 4 For any dispute involving the human rights or privacy when using our products please contact your employer directly Our biometric products for police use or development tools support the collection of the original biometric images As for whether such a type of biometric collection constitutes an
23. tem 8 2 Uploading Data Upload the user information and fingerprints saved in the USB disk to the device Operating instructions Insert a USB disk to the USB slot of the device and select Upload User Data Then the user dat file and template dat file are uploaded to the device If the two files are not available in the USB disk the system prompts Errors in copying data 9 System Information Through the System Information option you can query the storage information and version information of the current device System Info x User Enroll 4 Administator Enroll Password Enroll 3 User Finger Record Total 3000 1500 100000 Usable 2996 1495 99970 Algorithm er ZKFinger X9 0 FirmwareVer Yer 1 0 22 Appendix Appendix Appendix 1 T9 input method The T9 input method is the intelligent input mode which is famous for high input efficiency The device supports to input numbers English characters and symbols On the input panel the number keys 2 to 9 have three or four English letters for example the number key 2 has three letters including A B and C For T9 English input the English letters are inputted in an alphabetical order Press the corresponding number key once Then the program automatically displays all letters on the key and you can click the desired letter For the T9 input method you can click the key to input symbols Through the T9 input method you can input names and numbers input Pan
24. to be replaced on a regular basis such as batteries and so on The EFUP of batteries is 5 years Names and Concentration of Toxic and Hazardous Substances or Elements Toxic and Hazardous Substances or Elements Chip ae Chip inductor Chip oe compon ents e O Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement in SJ T 11363 2006 X Indicates that this toxic or hazardous substance contained in at least one of the homogeneous materials for this part is above the limit requirement in SJ T11363 2006 Note 80 of the parts in this product are manufactured with non hazardous environment friendly materials The hazardous substances or elements contained cannot be replaced with environment friendly materials at present due to technical or economical constraints Appendix 4 Environment Friendly Use Description 2