Home
ME901K Instruction - Musikelectronic Geithain GmbH
Contents
1. Directional characteristic 80 H 125 Hz musikelectronic geithain GmbH RL 901K ME 901K NON ss 14 8 Notes musikelectronic geithain GmbH RL 901K ME 901K NOTES 15 musikelectronic geithain GmbH RL 901K ME 901K musikelectronic geithain gmbh STUDIO MONITORING HIGHEND LOUDSPEAKER SOUND REINFORCEMENT SYSTEMS SYSTEMS NikolaistraBe 7 04643 Geithain Germany Wak Ae SASA Sio Fax 49 0 34341 31144 E Mail info me geithain de www me geithain de
2. Tweeter Operation and Clipping indicator Power requirements Power consumption Mains Connection Dimensions H x W x D RL 901K ME 901K Weight RL 901K ME 901K Temperature requirements for use for storage Humidity Design of the Cabinet RL 901K ME 901K musikelectronic geithain GmbH Active 3 way monitor for listening distances between 2 and 4 m 116 122 dB r 1 m 3 3 ft 25 Hz 20 kHz 3 dB 89 dB r 1m 3 3 ft Increasing from 5 to 10 dB lt 7 dB A r 1m 3 3 ft lt 44 dB 6 dBu adjustable 2 10 kOhm RC balanced 550 Hz and 2 8 kHz 180 Watt 4 Ohm 100 Watt 4 Ohm 100 Watt 4 Ohm XLR 3F 400 mm 16 cone 125 mm 5 cone 25 mm 1 dome LED on front side 230 Volt 10 50 Hz 115 Volt 10 50 Hz 100 Volt 10 50 Hz 60 Hz 60 Hz optional 60 Hz optional 35 VA at standby max 300 VA at full load IEC power connector 550 x 500 x 430 mm 21 6 x 19 7 x 17 inch 561 x 500 x 441 mm 22 1 x 19 7 x 17 4 inch 48 kg 105 6 Ibs 49 kg 107 8 Ibs 15 C 35 C 59 F 25 C 45 C 13 F 45 75 95 F 113 F MDF wood veneered or varnish with holding device with handles without holding device without handles RL 901K ME 901K ACOUSTIC MEASUREMENTS 15 7 Acoustic measurements All acoustic measurements are carried out under anechoic conditions with 1 m 3 3 ft distance
3. slightly moistened cloth musikelectronic geithain GmbH RL 901K ME 901K BASIC INFORMATION 6 3 3 Unboxing Unpack the speaker carefully and check for visible damages by inappropriate transport In case of damages report them to your retailer Keep the packaging in case the speaker has to be transported in the future 3 4 Delivery contents 4 Speaker 4 Mains cable 4 Technical description and user manual 3 5 Cleaning The speaker is made of real wood veneer and be nurtured in the same way as furnishings We advice quality wax polish to ensure durability of the veneer Surfaces can also be cleaned with tidy slightly damped fuzz free smooth cloth 3 6 Guarantee acknowledgements Opening the device by unauthorized personnel leads to all claims under guarantee expire In case of destruction by overload misuse or outside influences there are no claims under guarantee musikelectronic geithain GmbH RL 901K ME 901K POSITIONING 7 4 Positioning Our speakers do not impose special requirements neither in stereo nor in multichannel set ups No netheless speaker positioning has influence on listening impression because every room is individu ally designed and furnished The following advices are just guidelines that ease proper positioning In addition we offer a measurement service to take advantage of the capabilities of your listening environment 4 1 Positioning near walls When speakers are installed near walls so
4. Instructions for installation and use TABLE OF CONTENTS 2 Table of contents 1 Introduction 3 2 System description 4 3 Basic information 5 3 1 Guidelines 5 3 2 Safety instructions 5 33 Unboxing 6 3 4 Delivery contents 6 3 5 Cleaning 6 3 6 Guarantee acknowledgements 6 4 Positioning 7 41 Positioning near walls 7 4 2 Stereo operation 8 43 Surround operation 9 5 Connecting the speakers 10 5 1 Mains connection 10 5 2 Cable connection 10 53 Status indication 11 5 4 Adjustment controller 11 6 Technical data 12 7 Acoustic measurements 13 8 Notes 14 musikelectronic geithain GmbH RL 901K ME 901K INTRODUCTION 3 1 Introduction Dear customer Thank you for your trust you have put in us by buying these speakers You decided upon a quality product that in regard to tonal and technical characteristics complies to the utmost expectations The usual burn in period is not required because the speakers are artificially aged in house Please read the technical description and manual to take advantage of the capabilities of these speakers and ensure safe operation musikelectronic geithain GmbH RL 901K ME 901K SYSTEM DESCRIPTION 4 2 System description The speakers RL 901K and ME 901K are active 3 way monitors with cardioid radiation characteristics in the frequency range of 30 to 250 Hz The RL 901K is designed for professional users in medium size to large audio video or film studios For the discerning music enthusias
5. e center of this circle Position all speakers in the same distance to the hearing zone The center speaker is positioned in the middle between both front speakers Pay attention to positioning the front and rear speakers horizontally along one plane The angle between center and rear spea kers should be about 110 120 4 Distance between speakers and your listening position a 2 4m 6 13 ft musikelectronic geithain GmbH RL 901K ME 901K CONNECTING THE SPEAKERS 10 5 Connecting the speakers In this chapter we inform you how to connect your speakers to mains and your signal source Ensure that the mains switch on the backside is in position OFF Only when your speaker is completely con nected see chapters 5 1 and 5 2 you can take the device into operation by use of the mains switch 51 Mains connection Check the mains voltage state on the backside of the device If your local mains voltage does not match the specification of the speaker please refer to your retailer or direct distribution When the stated and your local mains voltage comply connect the mains connector of the speaker to the socket with the included mains cable 5 2 Cable connection The input of the integrated amplifier is electrically balanced When your signal source also utilizes balanced connectors please use a cable wired as stated in the table Balanced connector Balanced connector Unbalanced connector amplifier signal source Signal s
6. ic geithain GmbH RL 901K ME 901K BASIC INFORMATION 5 3 Basic information 3 1 Guidelines This product complies to reguirements of current European and national guidelines Elektromagne tische Vertr glichkeit 89 336 EWG Products built by us belong to B2C class of the WEEE guidelines and must not be disposed with domestic waste 3 2 Safety instructions Like using any other electrical device you should observe the following operation guidelines safety instructions and warning signs to ensure optimum functionality and safety of operation 4 Read these instructions carefully 4 Keep these instructions 4 Do not attempt to service this product yourself as opening or removing cover may expose you to dangerous voltage or other hazards Electrical devices are not intended for use by kids Operate this device only with the mains voltage stated on the backside Do not install the device near any heat sources Do not expose the device to direct sun radiation Do not install the device in rooms with high humidity Ensure sufficient air ventilation when installing the device in a shelf or wall Do not try to insert anything into device openings A A A A A A A A The device shall not be exposed to dripping or splashing and no objects filled with liquids shall be placed on the device 4 There is risk of electric shock when the device is open 4 Refer all servicing to qualified service personnel 4 Clean only with dry or
7. ource XLR XLR RCA Pin 1 Pin 1 Ring Pin 2 Pin 2 Tip Pin 3 Pin 3 Ring When using a signal source with unbalanced outputs RCA you need to balance the connecting cables This avoids hum and other noise interferences The table and the following figure show the wiring Unbalanced RCA to balanced XLR Connections Source RCA To carry the signal connect the XLR socket of the speaker to your signal source musikelectronic geithain GmbH RL 901K ME 901K CONNECTING THE SPEAKERS ili 53 Status indication The tow coloured LED at the front of the speaker is used as status indicator of the device 4 LED green indicates normal operation of the device 4 LED red indicates the operation of the overload protection circuit Output power limitation to protect the components from overloading 54 Adjustment controller The Level controller is used for level adjustment over the full frequency range musikelectronic geithain GmbH RL 901K ME 901K TECHNICAL DATA 6 Technical data General Maximum SPL from 100 Hz 6 kHz Bandwidth Calibration Acoustic output level PE 14 dBu Directivity index from 200 Hz 10 kHz Inherent noise sound level Total harmonic distortion measured at 96 dB r 1 m 3 3 ft from 100 Hz 10 kHz Nominal Input level Input impedance Electronic Crossover frequencies Nominal output power amplifier Input Connector Loudspeaker systems Woofer Mid range unit
8. t in the private domain the high end speaker ME 901K with added baffle was designed By the cardioid radiation characteristic of both speakers reflections on the back walls of listening rooms can be minimized The transfer characteristic can be matched to the acoustical conditions of the reproduction room as well as to the set up situation by a low frequent infinitely variable adap tation within two adjustable frequency ranges The unit for the medium and high frequency range is combined in a coaxial manner with a long throw bass system and is provided with a directivity index which supplements in an excellent way that of the bass system The total directivity index of the monitor was optimized for larger listening distances The whole system is superior by excellent localization behaviour The high power long throw bass system is driven in a compact cabinet so that optimum impulse behaviour can be reached Moreover with a series of constructional measures we have provided that convincing lowest values of non linear distortions and colorations could be reached The three channel MOSFET power amplifier with electronic crossover is integrated within the back wall of the cabinet An intermittent LED lighting signals when the overload limit is reached After crossing of the maximum level the output level will be reduced by 20 dB to avoid any overloading of the components A variety of special stands and racks is available as accessories musikelectron
9. und quality is physically affected Every customary speaker behaves as a punctual sonic source in the low frequency range with sonic waves spherical radiated without any constructional measures Back wall reflections are unavoidable The speakers however utilize cardioid radiation characteristics with rearward attenuation greater than 10 dB Because of this structural measurement installation near walls is considerably less cri tical For optimum listening experience a minimum distance of 20 cm 7 9 to walls and furniture should be ensured Avoid corner installations because unwanted bass accentuation could arise 4 Minimum distance to wall b 20 cm 7 9 musikelectronic geithain GmbH RL 901K ME 901K POSITIONING 8 4 2 Stereo operation The optimum position of the speakers in your listening environment is the so called stereo triangle see figure The base distance between the speakers and the distance to the hearing zone form an equilateral triangle stereo triangle A distance less than 2 m 6 ft or more than 4 m 13 ft should be avoided For precise spacial reproduction turn the speakers inside directed to the hearing zone hearing zone 4 Distance between speakers and your listening position a 2 4m 6 13 ft musikelectronic geithain GmbH RL 901K ME 901K POSITIONING 9 4 3 Surround operation In surround operation the stereo triangle see Stereo operation is extended to a circle The hearing zone is th
Download Pdf Manuals
Related Search
Related Contents
BC-14S Adjustable Anchor Clamp – Product Manual Pixtacy 4 Benutzerhandbuch 取扱説明書 DSSLF120 HX9400-S SDH/SONET ADM STM1/4 OC3/12 (Eng) Elinchrom Style RX 300/600/1200 slaa368 - Using the USI I2C Code Library ダウンロード(PDF 0.96MB) Digital Cable User Guide Highgrade A6041 Copyright © All rights reserved.
Failed to retrieve file