Home
Manual - WorldPoint
Contents
1. Head O nly Child Airway Management Trainer LF03610U LF03611U LF03612U LF03613U LF03614U LF03615U LFO3616U LFO3617U LFO3620U LFO3621U LFO3622U LF03623U LF03626U LF03627U LF03628U LF03629U LF03630U LF03631U LF03632U LF03633U LFO3650U LFO3651U LFO3675U LFO3676U LFO3677U LFO4001U LFO4020U LFO04021U LFO4022U LFO4030U LFO4040U Child Airway Management Trainer Head O nly Child Defibrillaton Chest Skin Child IV Arm Child Blood Pressure Arm Child Intraosseous Infusion Femoral Access Leg O nly Complete Child CRiSis Update Kit Child CRiSis Manikin Deluxe Child CRiSis Manikin with Arrhythmia Tutor PALS Update Kit Infant Airway Management Trainer Head O nly Intraosseous Infusion Right Leg Infant Airway Management Trainer Child Femoral Access Injection Pad Replacement Child CRiSis Replacement Lung Set Child CRiSis Replacement Stomach Child IV Arm Replacement Skin and Veins Child Arrhythmia Tutor Child Airway Management Trainer Replacement Headskin Child Intraosseous Infusion Femoral Access Leg ona Stand Child Airway Management Trainer with Torso CRiSis Manikin ALS Update Kit BLS Manikin 10 Pack BLS Manikin 5 Pack BLS Manikin Single GERi Nursing Manikin KERi Nursing Manikin KERi Basic Manikin KERi Advanced Manikin GERi Advanced Manikin GERi Basic Manikin Nasco Fort Atkinson 901 J anesville Avenue P O Box 901 Fort Atkinso
2. Masco Life form ADVANCED INJECTION HAND LFO1L139U amp LFO1146U INSTRUCTION MANUAL aa 4 j ue _ Life form Products by NASCO About the Simulator The Life form Advanced Injection Hand Simulator duplicates the human condition as closely as modern plastics technology allows it is almost the real thing Its care and treatment should be the same as with a patient abuse or rough handling will damage the simula tor just as it would cause pain or injury to a patient This unit is the simulation of the entire human hand from the wrist to the finger tips Externally the skin texture is realistic to the touch and the fingertips actually have fingerprints Although this hand will provide you long trouble free usage the skin and veins can be readily replaced when needed The outer skin is easily peeled off reveal ing the core and veins providing liter ally a brand new hand The life of the replaceable skin and veins will be pro longed by utilizing smaller needle sizes such as 20 to 25 gauge However if instruction with larger needle sizes is required this can be done the skin and veins will merely need to be replaced sooner Replacement Skin and Vein Kits are available through NASCO see list of supplies List of Components 3cc syringe with needle 12cc syringe with needle 2 IV bags Needle butterfly 2 pinch clamps 2 small towels Infusion set butterfly Internal Str
3. amp B Kinks in tubing of the fluid bags C Tubing pinched shut by constant pressure of clamps Lumen remains pinched occasionally even if the clamp is loosened Slide clamp to new position and with fingers manip ulate tubing at pinched site to restore lumen In heavy use slide clamp to new position on tubing from time to time to prevent the permanent pinch caused by constant clamp pressure D If these measures do not unclog the venous system try using a large 50cc syringe to force fluid through the tubing Care of Simulator After each class use close the clamps disconnect bags and return synthetic blood to storage container Reconnect one IV bag to the system Fill the bag with tap water and flush the venous system allowing the open end to drain into a sink or basin When the system runs clean close the clamp and remove the IV bag Excess water may be removed from the hand by raising the hand lowering the wrist and draining it into a sink or basin Wash the outside of the hand with Ivory liquid detergent and water Always remove the pinch clamps from the wrist tubing and drain excess water from veins before storing O rdinary stains can be removed by wash ing the hand with soap and warm water Newsprint similar printed paper or ink will permanently stain the simulator if prolonged contact occurs Stubborn stains may be removed with REN Cleaner W09919U simply by dispensing it on the area and wipin
4. g with a soft cloth or paper towel Other Available Life form Simulators LFOO698U LFOO856U LFOO901U LFOO906U LF00929U LF00957U LFOO958U LFOO961U LFOO984U LFOO995U LFO0997U LFOO999U LFO1008U LFO1012U LFO1019U LFO1020U LFO1025U LFO1026U LFO1027U LFO1028U LFO1036U LFO1053U LFO1054U LFO1062U LFO1063U LFO1064U LFO1068U LFO1069U LFO1070U LFO1082U LFO1083U LFO1084U LFO1087U LFO1094U LFO1095U LFO1108U LFO3000U LFO3601U LFO3602U LFO3603U LFO3609U Adult Injectable Arm White Female Catheterization Prostate Examination Ostomy Care Surgical Bandaging Enema Administration Pediatric Injectable Arm Intramuscular Injection Breast Examination Arterial Puncture Arm Adult Injectable Arm Black Pediatric Injectable Head Intradermal Injection Arm Heart Catheterization TPN Ear Examination Supplementary Ear Set Male Cath Ed Female C ath Ed Il Peritoneal Dialysis Suture Practice Arm Spinal Injection Cross Sectional Anatomy Torso Head Cross Sectional Anatomy Head Pelvic Normal amp Abnormal Stump Bandaging Upper Stump Bandaging Lower Brachial Plexus Cervical Effacement Birthing Station Cricothyrotomy Tracheostomy Care Sigmoidoscopic Examination Central Venous C annulation Cross Sectional Anatomy Laminated Blood Pressure Arm Intraosseous Infusion Simulator CP ARLENE Series Adult Airway Management Trainer Adult Airway Management on Manikin Adult Airway Management
5. l the outlet wrist tube to bag B runs free of bubbles When the outlet tubing to bag B runs clear of bub bles close the clamp on bag B Figure 3 5 The venous system is now full of blood and pressurized Be sure to leave the clamp on the inlet tubing bag A opened 6 The hand is now ready to practice drawing blood Blood can be drawn anywhere along the pathway of the vein see Figure 1 Distilled water should be used to prepare the sites Synthetic blood will actually be aspirated once the vein is properly punctured 7 Small diameter needles 20 to 25 gauge should be used B Preparing the Hand for Intravenous Infusions At this point you will need to supply an IV set and bag of solution Hook them up and have them ready 1 To hook up the hand refer back to steps 1 5 in section A 2 Insert the butterfly needle into a vein Flashback will indicate proper inser tion 3 If a flashback is observed close the clamp on IV bag A You are now ready to set up for the intravenous infusion 4 Hang the IV solution bottle and con nect the IV set to the butterfly needle already in the vein With the clamp on bag A closed open the clamp on bag B Proof of the proper procedure is evidenced by the flow of the infu sion fluid from the solution bag Control the flow from the solution bag by adjusting the roller clamp on the tubing of the IV set Causes for Failure in Function A Forgotten closed cl
6. n Wisconsin 53538 0901 920 563 2446 www eNASCO com E Mail lifeform eNASCO com COPYRIGHT NASCO 1999 PRINTED IN U S A NP 104 99
7. ucture Figure 1 Internally the vascular structure rubber tubing includes injectable metacarpal digital and thumb veins The venous sys tem is constructed of special self sealing rubber tubing with the lumen being the approximate size of a human vein Figure 1 The vascular structure has an inlet tube and an outlet tube below the wrist and it is via these tubes that the venous system is filled Thus the techniques of blood drawing and starting intravenous infusions may be practiced on the Advanced Injection Hand General Instructions for Use The Advanced Injection Hand comes with all of the supplies necessary to perform most procedures To perform intra venous infusions the user must supply their own IV set and bag of solution Figure 2 A Preparing the Synthetic Blood 1 Add 1 pint of distilled water to the synthetic blood concentrate Figure 2 2 Hang one of the bags bag A approximately 28 above the level of the hand making sure the clamp on the IV tubing is closed Pour the blood into the bag 3 Attach the fitting end of the IV tubing to one of the wrist tubes Important Note Before completing step 4 bag B must lie at hand level or below with the cap closed 4 With the other wrist tube attached to the empty IV bag bag B flush the vascular system with synthetic blood by opening the clamp of the filled IV bag bag A Figure 3 Allow some blood to pass through the system unti