DatamedRcv™ Module DRCV01 Service Manual
Contents
1. 2 ECable Mode Enable Disable 7 Enable ECable Mode Destination IP Address 192 168 1 13 The Destination IP and Port must match Destination Port 9100 E the installation settings for Connection attempt time 30 sec 1 DatamedRcv DRCVO1 Console Mode String E Port Filter TRAP Chapter 4 Configuring Serial to LAN Adapters Datamed LLC Y Engineering Solutions Inc Clicking on TCP IP in the left sidebar menu will bring up the Configure TCP IP screen Enter the IP address of the Silex adapter not the computer Although DHCP can be used a static IP address is strongly recommended Make note of the IP address by placing a label or sticker on the case of the adapter Click Submit to save the settings Configure TCP IP TCP IP Enable Disable SLX3B382D S1 A 4 Eas SLX3B382D S1 B i IP Address 192 168 112 Enter the IP Address and Subnet Mask 255 255 255 0 other settings IP Address Gateway 192 168 11 Boot Method STATIC Boot Tries _ L No Subnet Mask RARP Boot Settings No Gateway 2 Set address with ARP Ping LPD TCP port v FTP v Telnet S TELNET HTTP Applications Enabled HTTPS M POP SMIP SNMP DNS v TFTP ECHO TCP Window 10240 12 Timeout 1 min 12 2 C Banner Enable Settings LPD Retry Enable Keepalive Timer 1 ain Probe Idle Connections Enable Disable Access Control Config
2. DATAMED EKG FORMAT TRANSLATORS DatamedRcv Model DRCVO1 User s Manual Datamed LLC Engineering Solutions Inc DatamedRcv DRCVO1 v1 4 0 Doc ID DMD 10301 00100 Rev A 2 2012 DRCVO1 User s Manual COPYRIGHT Copyright 2007 2012 Datamed Engineering Solutions Inc Germantown TN 38138 U S Phone 800 601 3361 Int l Phone 1 901 672 6225 All rights are reserved Reproduction in whole or in part is prohibited without the prior written consent of the copyright holder WARRANTY Datamed LLC Engineering Solutions Inc DMESI makes no warranty of any kind with regard to this material included but not limited to the implied warranties or merchantability and fitness for a particular purpose The software described herein is covered by DMESI s standard EULA which is available on DMESI s website www datamed com and in Appendix C of this manual CAUTIONS This product is not intended for home use TRADEMARKS Datamed is a registered trademark of Carl E Osborne J r Microsoft Microsoft Windows XP and Internet Explorer are registered trademarks of Microsoft Corporation GE is a registered trademark of General Electric Company MAC Marquette and MUSE are registered trademarks of GE Medical Systems Information Technologies Inc ZOLL and M Series are registered trademarks of ZOLL Medical Corporation HASP and HASP SRM are registered trademarks of Aladdin Knowledge Systems LTD Hayes is a registe
3. 5500 only To set up the cardiograph for transmission use one of the following checklists When using a serial to LAN adapter or direct serial connection 1 2 3 4 10 11 12 13 14 Press More F6 then Main Menu then More F6 then System Setup Enter the system password and press Enter Select Basic System and press If you are using a serial to LAN adapter and connecting it with the special cable that supplies power as opposed to using an A C adapter you will need to turn on power to the external adapter This will increase the power consumption slightly but it is needed for proper operation Perform the following steps a Select Miscellaneous Setup and press b Select Serial Power Always On and press then select Yes and press C Select Return and press Select Transmission and press Select Use IR for Serial Line and press then select No and press NOTE this setting may not be present depending on the cart firmware Select Serial Line Baud Rate and press then select 115 2k and press If the maximum setting is less than 115 2k e g 9600 or 19200 set it to the maximum and the SENA adapter must be used instead of the Silex adapter Select Default Location and press then select Serial Line MUSE and press Select Return and press Again select Return and press Select Save Setup and press Select Main Menu and press to get back to the main menu Pr
4. At the login screen the default password is access Click Submit to login silex Network Configuration Login silex SX 500 WLAN Network Card Access Password Server Info Port Services TCP IP PrintraNet Wireless Admin ogout Language English Francais Deutsch Italiano Japanese Espa ol Internet 100 IMPORTANT NOTE When making changes press the Submit button at the bottom of each page but don t press Reset until all changes have been saved Note that due to a quirk in the web interface the saved settings may not show up on the screen until the adapter has been reset even though they have actually been saved Once all desired changes have been saved press the reset switch To restore the factory settings press and hold the reset switch on the adapter for 5 seconds Datamed LLC Y Engineering Solutions Inc Chapter 4 Configuring Serial to LAN Adapters DRCVO1 User s Manual Clicking on I O Port in the left sidebar menu will bring up the I O Port Setting screen The important changes are described below Some firmware versions add a setting called Local Port below Destination Port and it should be set to the same value as Destination Port Click Submit to save the settings I O Port Settings Port Name 51 Port Type Serial Baud Rate should Baud Rate 115200 be set to 115 200 Bits per character 1 Stop Bits 1 1 Parity None Flow Control None
5. modem or direct cable In other words you can have several modems or several direct cables but not a mix of the two Baud Rate This allows the baud rate of the serial port s to be set Some carts can only support limited baud rates so this setting must be matched to the cart setting for direct serial connections For modem connections this can normally be set to 57600 or 115200 Note that if multiple ports are configured they will all be set to the same baud rate Using modem s on the serial port s If this box is checked all selected ports must be connected to modems Modem init string This string identifies commands that are sent to the modem to set it up for reception The default string is correct for MultiTech modems and should not normally be changed Chapter 5 Configuring DRCVO1 Datamed LLC Engineering Solutions Inc Direct Connections Tab This tab contains the settings for TCP IP connections that use the built in LAN port on certain MAC cardiographs Note that the LAN Option must be turned on in the cart to use this connection Each setting is described below Configuration Utility for DatamedRcv DRCVO1 File Output folder C DatamedFT EKGsfromGE File TCP IP and Serial Listeners Direct Connections Advanced v Enable direct connections to LAN equippped cardiographs Enter the cart addresses with each entry on a separate line lt gt lt 192 168
6. to access a list of EKG files to transmit After selected the desired files press Transmit F4 to send the selected files Important Note MAC 5500 with v10 firmware requires DatamedFT v2 0 13 or higher Chapter 3 Configuring Transmitting Devices Datamed LLC Y Engineering Solutions Inc CHAPTER 4 CONFIGURING SERIAL TO LAN ADAPTERS devices that support a baud rate of 115 200 115 2k If the device does not support this baud rate then we recommend the SENA adapters Other serial to LAN adapters are available but they have not been tested by DMESI T he Silex Technology SX 500 product is the preferred adapter however it will only work with Before beginning the installation it is critical that the network information is gathered DMESI recommends that a static IP address be used for the adapter connections will require the static IP address of the computer that is running DRCVO1 as well as the IP address of the adapter static address with gateway and subnet mask or DHCP In addition for wireless connections the wireless network connection settings MUST be available These settings include the SSID security type WEP WPA etc and passwords Silex Technology SX 500 Serial to LAN Adapter The SX 500 1031 US and SX 500 1033 Europe product supports both wired and wireless LAN configurations The manual for the Silex adapter is available online at http silexamerica com us support Documentation doc
7. Datamed R Software Copyright c Datamed LLC Engineering Solutions Inc Press the Collect information button and select a folder and filename to save the License Update Request File c2v to Please use the facility name and date as part of the filename Email the file to support datamed com When you receive the License Update File v2c back select the Apply License Updatetab and use the button to select the file Press Apply updateto update the license Datamed LLC Y Engineering Solutions Inc Appendix A Updating the Hardware Security 35 Key DRCVO1 User s Manual Step 4 Step 5 Step 6 Step 7 Step 8 There are two tabs on the screen Collect Key Status Information and Apply License Update On the first tab press the Collect information button A dialog box will open asking for a name and location to save the output file Name the file using the company or facility name and the current date Press the Save button to create the file A file will be created in the location specified with an extension of c2v Email this file to DMESI at support datamed com DMESI will generate and update file with an extension of v2c email it back Save this file in the same folder as the c2v If the utility was closed restart it Select the Apply License Update tab and press the button to open a dialog box where you can locate the v2c file Press the Open button to load the update file En
8. Engineering Solutions Inc Appendix C End User License Agreement and 43 Limited Warranty DRCVO1 User s Manual provision of this EULA shall be limited to the amount actually paid by you for the Product These limitations do not apply to any liabilities that cannot be excluded or limited by applicable laws Consumer Rights Consumers in Australia New Zealand or Malaysia may have the benefit of certain rights and remedies by reason of the Trade Practices Act and similar state and territory laws in Australia the Consumer Guarantees Act in New Zealand and the Consumer Protection Act in Malaysia in respect of which liability cannot lawfully be modified or excluded If you acquired the Product in New Zealand for the purposes of a business you confirm that the Consumer Guarantees Act does not apply If you acquired the Product in Australia and if Licensor breaches a condition or warranty implied under any law which cannot lawfully be modified or excluded by this agreement then to the extent permitted by law Licensor s liability is limited at Licensor s option to i in the case of the Product a repairing or replacing the Product or b the cost of such repair or replacement and ii in the case of support services a re supply of the services or b the cost of having the services supplied again Should you have any questions concerning this EULA or if you desire to contact Licensor for any reason please use the address information encl
9. is also compatible with the built in LAN port for MAC cardiographs that support it and have the option activated 800 1600 3500 5500 mm Chapter 1 Getting Started Datamed LLC X Engineering Solutions Inc CHAPTER 2 INSTALLATION Requirements Hardware Security Key If this is a new installation you should receive a hardware security key HASP This key is required for the software to run If you are installing this software on a computer that already has a hardware security key for Datamed Format Translator Software then you will need to update that key to add a license for DRCVO1 See Appendix A for instructions on how to update the key Software CD or installation package from DMESI GE Marquette or compatible device that will transmit to DRCVOl using the CSI protocol or XML dump Datamed EKG Format Translator software already installed and configured Computer DRCVOI is typically installed on the computer with the Datamed EKG Format Translator software however it can be installed on a separate computer instead The minimum specifications for this computer are 256 MB RAM 20 GB HD one unused USB Port for the Hardware Security Key and a LAN connection for file transmission The following operating systems are supported Y Windows XP x86 and x64 Windows Vista x86 Windows 7 x86 Windows Server 2003 x86 Windows Server 2003 R2 x86 Windows Server 2008 x86 See Chapter 6 for information about ru
10. printed materials or user documentation accompanying the Product if any vi reverse engineer decompile or disassemble the Product except and only to the extent that such activity is expressly permitted by this EULA or applicable law notwithstanding this limitation vii transfer or assign the license and your rights to the Product under any circumstances including to an affiliate or any other entity under common ownership with you or under your control or upon a merger change of control reorganization consolidation or sale of all or substantially all of your assets or seek to sublicense or assign the license of your rights hereunder viii Distribute rent sell loan lease sublicense provide commercial hosting services or otherwise deal in the Product and or any other component elements of the Product Datamed LLC Engineering Solutions Inc Appendix C End User License Agreement and 39 Limited Warranty DRCVO1 User s Manual ix use the Product to facilitate or perform bulk translations of any electrocardiogram data or any other data that may be processed through the Product and or x use the Product on or in connection with an application service provider platform or other hosted website application or platform or as a software as a service You agree that in the event of actual or threatened breach of this Section by you Licensor will have no adequate remedy at law and will be entitled to immediate and injuncti
11. 1 23 3001 192 168 1 23 3001 Validate Entries Service Status Stopped Save Changes Direct Connection Settings Enable direct connections to LAN equipped cardiographs If this box is checked connections will be established with all of the carts listed in the address box Enter the cart addresses This text box must contain the IP address and port of each LAN equipped cart that will be connected In contrast to the TCP IP Settings where the address of this computer was used the setting here is the address configured in the cardiograph itself The format of each line is the IP address then a colon and then the port number Validate Entries After entering the cart addresses in the text box press this button to validate the formatting of the addresses Any invalid entries will be removed Datamed LLC Y Engineering Solutions Inc Chapter 5 Configuring DRCVO1 DRCVO1 User s Manual Advanced Tab This tab contains the advanced settings These settings are for advanced users and will normally only be used with directions from DMESI support personnel Each setting is described below Configuration Utility for DatamedRcv DRCVO1 File Output folder CADatamedFTXEKGsfromGEFile eS SSS TCPAIP and Serial Listeners Direct Connections Advanced Transmission Forma GEFile GEXML The Transmission Format setting only applies to TCP IP connections and Serial without modem connections Dir
12. 1 4 0 has been updated successfully Run the DatamedRev DRCVOTConfig utility to update the settings and start the service Please click Finish to exit this installer gt The settings are not changed during an update but the services must be restarted Use the DRCV01Config utility to restart them Chapter 2 Installation Datamed LLC Y Engineering Solutions Inc Uninstalling To uninstall DRCVO1 do of the following 1 from Start All Programs Datamed DatamedRcv DRCVO0I select Uninstall DRCVO1 or 2 open Control Panel choose Add or Remove Programs select DatamedRcv DRCVOI and press the Remove button In either case the application will be removed It may take a minute for the uninstall to complete Note that only the application is removed all ECG files and logs will remain Datamed LLC Y Engineering Solutions Inc Chapter 2 Installation DRCVO1 User s Manual T CHAPTER 3 CONFIGURING TRANSMITTING DEVICES he device that transmits EKGs to DRCVO1 must be configured properly to be able to transmit EKGs successfully The following information should be used to assist in this setup Always consult the manufacturer s manual in conjunction with these instructions GE MAC 5000 and MAC 5500 Cardiographs These cardiographs can be configured to transmit using a modem a direct serial connection a LAN WLAN network using a serial to LAN adapter or using the built in LAN connection MAC
13. 168 1 25 3001 b DisplayName REG SZ DatamedRcv DRCVOI EnableDirectConnections REG 5Z Yes lab EnableSerialListener REG SZ No EnableTCPListener REG_SZ Yes 9 ErrorControl REG_DWORD Ox00000001 1 ab ImagePath REG EXPAND SZ C Program FilesiDatamedlDatamedRcv DRCV01 DatamedRcv_DRCVO1 exe InstallVersion REG SZ 1 ab Modemlnit REG SZ 8 050 1 ObjectName REG SZ LocalSystem OutDir REG_SZ C DatamedFT EKGsfromMACcsoo0 SerialPort REG SZ REG DWORD 0 00000003 3 C3 Dnscache b TCPAddress 192 168 1 20 B Dotasvc TCPPort 9100 E dptizo TransmitFormat GEFile a obs REG DWORD 0500000010 16 lt gt LIsingModem REG SZ Yes ComputeriHKEY LOCAL MACHINEYSYSTEM CurrentControlSetiServicesiDatamedRcv DRCVO1 Most of the settings must not be changed or the operation of DRCVOI will be affected If any setting is changed DatamedRcv_DRCV01Start must be restarted Datamed LLC Engineering Solutions Inc Appendix B Registry Settings DRCVO1 User s Manual APPENDIX C END USER LICENSE AGREEMENT AND LIMITED WARRANTY The current End User License Agreement and Limited Warranty EULA can be found on DMESI s web site www datamed com The following EULA was current at the time of this printing End User License Agreement for Datamed Software IMPORTANT READ CAREFULLY This End User License Agreement EULA is a legal agreement between you either an individual or a single entity
14. 5 0 Current IP 192 168 1 12 Admin Username admin Password admin Devicename LS100W Device IP_mode dhcp Allowed _ 0 0 0 0 Allowed Subnet mask 0 0 0 0 Host Host mode tcpc Destination IP 192 168 1 13 Destination port 9100 Cyclic connection interval min 0 Inactivity timeout sec 0 Serial Baudrate 115200 Data bits 8 bits Parity None Stop bits 1 bit Flow_control None DTR_option Always_high DSR_option None Interchar_timeout ms 100 wlan SSID TestSSID Type Infrastructure National Code USA Encryption Type 128bit Key Input Method Alphanumeric WEP Key ABCDEFGHIJKLM Datamed LLC Engineering Solutions Inc Chapter 4 Configuring Serial to LAN Adapters DRCVO1 User s Manual CHAPTER 5 CONFIGURING DRCVO1 DRCVO1Config utility that is installed along with the service Open the utility from the desktop shortcut or from the Windows Start menu and it will automatically read the current configuration settings from the registry When configuration changes are made they must be saved and then the service must be restarted for them to take effect nce DRCVOI is installed changes to the configuration settings can be done using the Window Settings At the top of the window there is one item Output folder The folder that incoming EKG files are written to This folder should belocal on this PC and must correspond to the Input Fold
15. HIPAA OR OTHER FEDERAL OR STATE STATUTES OR REGULATIONS YOU ARE SOLELY RESPONSIBLE FOR ENSURING THAT YOUR USE OF THE PRODUCT RELATED SERVICES OR CONTENT IS IN ACCORDANCE WITH APPLICABLE LAW IT IS YOUR RESPONSIBILITY TO KEEP ABREAST OF CHANGES IN LAWS REGULATIONS AND HEALTHCARE PRACTICES THAT AFFECT YOU AND YOUR BUSINESS You shall indemnify and hold Licensor harmless from and against any costs losses liabilities and expenses including reasonable attorneys fees arising out of any claims related to your use of the Product or violation of this EULA 9 EXCLUSION OF INCIDENTAL CONSEQUENTIAL AND CERTAIN OTHER DAMAGES TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW IN NO EVENT SHALL LICENSOR OR ITS REPRESENTATIVES BE LIABLE FOR ANY SPECIAL INCIDENTAL PUNITIVE EXPECTATION INDIRECT OR CONSEQUENTIAL DAMAGES WHATSOEVER INCLUDING BUT NOT LIMITED TO DAMAGES FOR LOSS OF PROFITS OR CONFIDENTIAL OR OTHER INFORMATION FOR BUSINESS INTERRUPTION FOR PERSONAL INJURY FOR LOSS OF PRIVACY FOR FAILURE TO MEET ANY DUTY INCLUDING OF GOOD FAITH OR OF REASONABLE CARE FOR NEGLIGENCE AND FOR ANY OTHER PECUNIARY OR OTHER LOSS WHATSOEVER ARISING OUT OF OR IN ANY WAY RELATED TO THE USE OF OR INABILITY TO USE THE PRODUCT THE PROVISION OF OR FAILURE TO PROVIDE SUPPORT OR OTHER SERVICES INFORMATION SOFTWARE AND RELATED CONTENT THROUGH THE PRODUCT OR OTHERWISE ARISING OUT OF THE USE OF THE PRODUCT OR OTHERWISE UNDER OR IN CONNECTION WITH ANY PROVISION OF TH
16. IS EULA EVEN IN THE EVENT OF THE FAULT TORT INCLUDING NEGLIGENCE MISREPRESENTATION STRICT LIABILITY BREACH OF CONTRACT OR BREACH OF WARRANTY OF LICENSOR OR ANY Datamed LLC Engineering Solutions Inc Appendix C End User License Agreement and 41 Limited Warranty DRCVO1 User s Manual REPRESENTATI VE AND EVEN IF LICENSOR OR ANY REPRESENTATI VE HAS BEEN ADVISED OF THE POSSI BILITY OF SUCH DAMAGES 10 LIMITATION OF LIABILITY AND REMEDIES Notwithstanding any damages that you might incur for any reason whatsoever including without limitation all damages referenced herein and all direct or general damages in contract or anything else the entire liability of Licensor and any of its Representatives under any provision of this EULA and your exclusive remedy hereunder except for any remedy of repair or replacement elected by Licensor with respect to any breach of the Limited Warranty shall be limited to the lesser of i the actual damages you incur in reasonable reliance on the Product or ii the license fees actually paid by you for the Product The foregoing limitations exclusions and disclaimers including Sections 8 9 10 and 11 shall apply to the maximum extent permitted by applicable law even if any remedy fails its essential purpose The disclaimers and limitations on liability set forth above are fundamental elements of the basis of the agreement between Licensor and you 11 Export Restrictions You acknowledge and
17. RCVO1Start are to start and stop DatamedRcv_DRCVO1 as well as to monitor it If DatamedRcv DRCVOI stops for some reason unrelated to the hardware security key DatamedRcv_DRCVO1Start will restart it During installation DatamedRcv DRCVOI s startup type will be set to Manual and DatamedRcv DRCVOIStart s startup type will be set to Automatic DatamedRcv DRCVOI should never be started or stopped directly When DatamedRcv_DRCVO1Start is started or stopped it will take care of DatamedRcv DRCVOl The DRCVO1Config utility should be used to start stop and monitor the services W hen DRCVOI is installed two new Windows services are created DatamedRcv DRCVO01 and If there is a problem the first place to look is the Event Viewer which can be accessed from Control Panel Administrative Tools Once the viewer is opened select Application from the left side menu and the right side will be filled with the application event log Double clicking on any entry in the log will open a window that shows the details for the event The Type column in the log will indicate whether this is an Information or Error message and the Source column will indicate what service logged the entry The Information messages are normal and for a normal startup there will be one from DatamedRcv DRCVOIStart Service started successfully and three or four from DatamedRcv DRCVOI1 depending on whether TCP IP serial or both connections are used The Error messages describe problem
18. SA 800 601 3361 or 1 901 672 6225 8 DISCLAI MER OF WARRANTIES The Limited Warranty above is the only warranty made to you and is provided in lieu of any other warranties or similar obligations if any created by any advertising documentation packaging or other communications No employee agent representative or affiliate of Licensor has authority to bind Licensor to any oral representations or warranty concerning the Product Any written representation or warranty not expressly contained in this EULA will not be enforceable EXCEPT FOR THE LIMITED WARRANTY THE PRODUCT SOFTWARE RELATED MATERIALS DOCUMENTATION AND OR ANY SERVICES RELATED TO THE PRODUCT ARE PROVIDED AS IS WITH ALL FAULTS AND TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW LICENSOR AND ITS SUBSIDIARIES AFFILIATES LICENSORS DISTRIBUTORS DEALERS OR SUPPLIERS REPRESENTATIVES DISCLAIM ALL OTHER REPRESENTATIONS AND WARRANTIES EXPRESS OR IMPLIED REGARDING THE PRODUCT SOFTWARE RELATED MATERIALS CONTENT AND ANY SERVICES INCLUDING FITNESS FOR A PARTICULAR PURPOSE SECURITY QUALITY MERCHANTABILITY AND THEIR NON INFRINGEMENT LICENSOR EXPRESSLY DISCLAIMS ANY REPRESENTATIONS OR WARRANTIES THAT YOUR USE OF THE PRODUCT WILL SATISFY ANY STATUTORY OR REGULATORY OBLIGATIONS OR WILL ASSIST WITH GUARANTEE OR OTHERWISE ENSURE COMPLIANCE WITH ANY APPLICABLE LAWS OR REGULATIONS INCLUDING BUT NOT LIMITED TO THE HEALTH INSURANCE PORTABILITY AND ACCOUNTABILI TY ACT OF 1996
19. VERABILI TY This EULA including any addendum or amendment to this EULA which is included with the Product is the entire agreement between you and Licensor relating to the Product and the support services if any and they supersede all prior or contemporaneous oral or written communications proposals and representations with respect to the Product or any other subject matter covered by this EULA This EULA sets forth the entire liability of Licensor and its representatives and your exclusive remedy with respect to the Product and services and their use To the extent the terms of any Licensor policies or programs for support services conflict with the terms of this EULA the terms of this EULA shall control Any waiver of the terms herein by Licensor must be in a writing signed by an authorized 42 Appendix C End User License Agreement and Limited Warranty Datamed LLC Engineering Solutions Inc officer of Licensor and expressly referencing the applicable provisions of this EULA If any provision of this EULA is held to be void invalid unenforceable or illegal it shall be enforced to the extent permissible and all other provisions shall continue in full force and effect Headings are included for convenience only and shall not be considered in interpreting this Agreement This EULA does not limit any rights that Licensor may have under trade secret copyright patent or other laws The following Licensor GUARANTEE applies to you if you
20. acquired this Product in any country other than the United States Statutory rights not affected The following guarantee is not restricted to any territory and does not affect any statutory rights that you may have from your reseller or from Licensor if you acquired the Product directly from Licensor If you acquired the Product or any support services in Australia New Zealand or Malaysia please see the Consumer rights section below The Guarantee The Product is designed and offered as one of Licensor s Datamed products You accept that no Product is error free and you are strongly advised to back up your files regularly Provided that you have a valid license Licensor guarantees that a for a period of 90 days from the date of receipt of your license to use the Product or the shortest period permitted by applicable law it will perform substantially in accordance with any written materials that accompany the Product and b any support services provided by Licensor shall be substantially as described in applicable written materials provided to you by Licensor and Licensor s support engineers will use reasonable efforts care and skill to solve any problem issues Acknowledging that Licensor has limited support resources all support will be done remotely from Licensor s home location In the event that the Product fails to comply with this guarantee Licensor will either a repair or replace the Product or b return the price you paid This guar
21. agree that the Product is subject to restrictions and controls imposed by the Export Administration Act of 1979 as amended and the Export Administration Regulations thereunder the Acts You agree and certify that neither the Product nor any direct product thereof is being or will be used for any purpose prohibited by the Acts You further agree and certify that neither the Licensor Product nor any direct product thereof will be exported to i the following countries which are currently subject to U S trade embargoes Cuba Iran Libya North Korea Sudan and Syria or ii persons or entities on the U S Denied Persons List Specially Designated Nationals List and Entities List 12 U S GOVERNMENT LICENSE RIGHTS All Product provided to the U S Government pursuant to solicitations issued on or after December 1 1995 is provided with the commercial license rights and restrictions described elsewhere herein All Product provided to the U S Government pursuant to solicitations issued prior to December 1 1995 is provided with Restricted Rights as provided for in FAR 48 CFR 52 227 14 JUNE 1987 or DFAR 48 CFR 252 227 7013 OCT 1988 as applicable 13 APPLI CABLE LAW This EULA is governed exclusively by the laws of the State of Tennessee USA The state and federal courts located in Shelby County Tennessee shall have exclusive jurisdiction to adjudicate any dispute arising out of or relating to this Agreement 14 ENTIRE AGREEMENT SE
22. allation CD or in the installation package locate DatamedRcv 01 Setup exe and double click on it The following screen should appear Click Next to continue T DRCVO1 tm Setup Welcome Welcome to the installer for DRCVOT tm v1 4 0 It is strongly recommended that you exit all Windows programs before continuing with this installation If you have any other programs running please click Cancel close the programs and run this setup again Otherwise click Next to continue Cancel Datamed LLC Engineering Solutions Inc Chapter 2 Installation DRCVO1 User s Manual gt Read the License Agreement carefully and select Agree Click Next to continue 9 DRCVO1 tm Setup License Agreement Please read the following license agreement carefully End User License Agreement for Datamed R Software IMPORTANT READ CAREFULLY This End User License Agreement EULA is a legal agreement between you either an individual or a single entity and Datamed LLC Engineering Solutions Inc Licensor for the Datamed R software that accompanies this EULA which may include associated media and printed and or agree to the terms of this license agreement 1 do not agree to the terms of this license agreement lt Back al Cancel gt Select the installation folder for the program and then click Next to continue 9 DRCVO1 tm Setup Installation Folder Where would you like Da
23. and Datamed LLC Engineering Solutions Inc Licensor for the Datamed software that accompanies this EULA which may include associated media and printed and or electronic documentation Product An amendment or addendum to this EULA may accompany the Product YOU AGREE TO BE BOUND BY THE TERMS OF THIS EULA BY INSTALLI NG COPYI NG OR USING THE PRODUCT 1 LICENSE AND USE 1 1 Grant of License n consideration for your agreement to the terms and conditions of this EULA Licensor hereby grants to you a limited non exclusive non transferable non sublicensable license to use and allow your employees Authorized Users to use the Product in object code form only for your own internal business purposes and subject to the terms and conditions contained herein 1 2 Installation and Use for Protected Products For each valid license purchased you may install and use a single copy of the Product on a single computer actual or virtual The Product is protected by either a Hardware Security Key or a Software Activation Code to prevent the operation of the Product on more than one computer By installing the Product you expressly agree to the installation of the appropriate drivers for the Hardware or Software protection mechanism You may physically transfer the Product between computers provided that it is used on only one computer owned and controlled by you at any given time for each license purchased You acknowledge and agree that any Har
24. antee is void if failure of the Product results from accident abuse or misapplication Any replacement Product will be guaranteed for the remainder of the original guarantee period or 30 days whichever period is longer You agree that the above guarantee is your sole guarantee in relation to the Product and any support services Exclusion of All Other Terms To the maximum extent permitted by applicable law and subject to the guarantee above Licensor disclaims all warranties conditions and other terms either express or implied whether by statute common law collaterally or otherwise including but not limited to implied warranties of satisfactory quality and fitness for particular purpose with respect to the Product and any written materials that accompany the Product Any implied warranties that cannot be excluded are limited to 90 days or to the shortest period permitted by applicable law whichever is greater Limitation of Liability To the maximum extent permitted by applicable law and except as provided in the Licensor Guarantee Licensor and its Representatives shall not be liable for any damages whatsoever including without limitation damages for loss of business profits business interruption loss of business information or other pecuniary loss arising out of the use or inability to use the Product even if Licensor has been advised of the possibility of such damages In any case Licensor s entire liability under any Datamed LLC
25. ardware Security 35 Appendix B Registry 37 Appendix C End User License Agreement and Limited Warranty een nnn 38 Datamed LLC Y Engineering Solutions Inc Table of Contents DRCVO1 User s Manual CHAPTER 1 GETTING STARTED he DatamedRcv Model DRCVO1 Receiver Module DRCVO1 is an accessory program for the Datamed EKG Format Translator family It runs as a system service and will monitor one or more serial ports and or a TCP IP port for connections from GE Marquette cardiographs and monitors that transmit using the CSI protocol as well as ZOLL defibrillators These devices typically either do not have an alternative method for transmitting the EKGs or it is difficult to accomplish As each EKG is received by DRCVOI it is written to a specific output folder where the Datamed EKG Format Translator software will pick it up and translate it to the appropriate destination format and location The following list describes the native method of transmitting EKGs for each of the devices GE MAC 600 This cardiograph can transmit through the serial port with or without a modem or it can write files to an SD card GE MAC 800 This cardiograph can transmit through the serial port with or without a modem through the built in modem if installed or through the built in LAN port if the option is enabled It ca
26. atory and can be resolved by correcting the setting or condition that caused them When working with DMESI support personnel a key piece of information is the configuration settings To export these to a file to email DMESI start the DatamedFT Configuration Utility and select File Export settings to file on the menu Datamed LLC Y Engineering Solutions Inc Chapter 6 Troubleshooting DRCVO1 User s Manual Here are some common issues and answers e Symptom The Security Key cannot be located o The Security Key is required for the DatamedRcv DRCVOI service to run Whether the Security Key is attached to the computer directly attached to the VM s host computer or connected by network it must be accessible and a local driver must be installed To verify that the key is connected do one or both of the following Start the Configuration Utility and select Help About on the menu After a moment it should show the Security Key serial number Open a browser and connecting to this address http localhost 1947 If the complete driver package is properly installed you should see the HASP Admin Control Center If you do not see this use the shortcut under Start All Programs gt Datamed DatamedRcv DRCVO1 Install HASP Security Key Drivers or download and install the latest driver which can be found at ftp ftp aladdin com pub hasp Sentinel HASP Runtime 280 29 S entinel LDK Run
27. ched by email at support datamed com or by phone at either 800 601 3361 ext 2 within the US or 1 901 672 6225 ext 2 outside the US 34 Datamed LLC Y Engineering Solutions Inc APPENDIX UPDATING THE HARDWARE SECURITY KEY using a hardware key the software can be moved to another computer if necessary unlike Software Activation which ties the software to a specific computer All that is required for the hardware key is a USB port T he hardware security key is used to control licensing for Datamed software applications By Upon delivery of the Datamed software the key will already be programmed with the appropriate licensing information If additional software licenses are purchased the key can be updated remotely to activate the new licenses This is accomplished by using the Datamedv2LicenseUpdate utility The utility will gather information from the key and save it to a file which is emailed to DMESI for updating DMESI will return an update file by email and the utility is used to apply the update to the key The entire process can be accomplished in a few minutes The following is a step by step procedure Step 1 Get Datamedv2LicenseUpdate zip from the website or by email and unzip it to a temporary folder Step 2 sure the security key is installed on the computer Step 3 Run Datamedv2LicenseUpdate exe You will see the following screen ni License Update Utility for
28. ct and any copies thereof or derivative works thereto The Product is licensed not sold This EULA does not grant you any rights to trademarks or service marks of Licensor Notwithstanding anything herein to the contrary you agree to not use or exploit the Product as a source or reference to conceive create develop or offer any product or service similar in form function or concept to the Product 3 FEEDBACK Licensor may provide you with a mechanism to provide feedback suggestions and ideas if you choose about its products and services Feedback You agree that Licensor may in its sole discretion use the Feedback you provide to Licensor in any way including in future modifications of the Product You hereby grant Licensor a perpetual worldwide fully transferable irrevocable royalty free license to use modify create derivative works from distribute and display any information you provide to Licensor in the Feedback 4 RESTRICTIONS LIMITATIONS ON REVERSE ENGINEERING DECOMPILATION AND DI SASSEMBLY You are not licensed or permitted to do nor may you permit your Authorized Users to i make additional copies of the Product except as provided herein ii enable others to use your registration code s or serial numbers if any iii give copies to another person who has not purchased a license for the Product from Licensor iv duplicate the Licensor Product by any other means including electronic transmission v copy the
29. dware Security Key or Software Activation Code that is lost will not be replaced under any circumstances 1 3 Installation and Use for Accessory Products For each valid license of Datamed Format Translator Software purchased you may install and use a single copy of the Product on a single computer actual or virtual The Product is designed to work only in conjunction with and as an accessory to properly licensed Datamed Format Translator Software 1 4 License Grant for Documentation Any documentation that accompanies the Product is subject to the license set forth in Section 1 1 and may only be used for internal non commercial reference purposes only 38 Appendix C End User License Agreement and Limited Warranty Datamed LLC Engineering Solutions Inc 1 5 Use of the Product You and Your Authorized Users agree to use the Product in compliance with all applicable federal state and local laws rules and regulations You are solely responsible for the adequacy and accuracy of all data programs procedures and other information that you and or your Authorized Users input into the Software and the results obtained therefrom 2 RESERVATION OF RIGHTS AND OWNERSHIP Licensor reserves all rights not expressly granted to you in this EULA The Product is protected by copyright and other intellectual property laws and treaties Licensor or its Representatives own the title copyright and other intellectual property rights in the Produ
30. ect LAN connections and Serial with modem connections always transmit in GEFile format Enable Debugging Service Status Stopped Save Changes Advanced Settings 3 Transmission Format This setting specifies the formatting of the data that is being transmitted It does not apply to direct LAN connections or serial connections that use a modem When setting up the Transmission Settings on the cardiograph two choices are Serial Line MUSE which corresponds to the GEFile format and Serial Line XML which corresponds to the GEXML format GEFile format is normally selected because it is the native format of the device and because it has error checking built in to the transmission Note that for extremely high rate EKGs 250bps artifacts may appear in the waveforms due to the characteristics of the file format This specific issue is also observed in native GE implementations MUSE Enable debugging In the event that there is a problem with the translator DMESI support personnel may want to collect detailed technical information After checking this option and restarting the service files containing debugging information will be written to the Output Folder This information should be sent to DMESI support for analysis See Chapter 6 for more details Chapter 5 Configuring DRCVO1 Datamed LLC Engineering Solutions Inc CHAPTER 6 TROUBLESHOOTING DatamedRcv DRCVOIlStart The functions of DatamedRcv_D
31. er for DRCVUT tm This program will update the software to v1 4 0 lt is strongly recommended that you exit all Windows programs before continuing with this installation If you have any other programs running please click Cancel close the programs and run this setup again Otherwise click Next to continue Ce DRCVO1 tm Setup License Agreement Please read the following license agreement carefully End User License Agreement for Datamed R Software IMPORTANT READ CAREFULLY This End User License Agreement EULA is a legal agreement between you either an individual or a single entity and Datamed LLC Engineering Solutions Inc Licensor for the Datamed R software that accompanies this EULA which may include associated media and printed and or agree to the terms of this license agreement 1 do not agree to the terms of this license agreement Datamed LLC Engineering Solutions Inc Chapter 2 Installation DRCVO1 User s Manual Click Next to begin installing the update DRCVO1 tm Setup Ready to Update You are now ready to install the DatamedRcv DRCVUT v1 4 0 update The installation of DatamedRicv DRCVUT located in C Program Files Datamed D atamedRicv DRCVO will be updated Please click Next to proceed with the update Onceinstallation is complete click Finish to close the window tm Setup Update Successful 01 v
32. er setting for the DatamedFT installation The Browse button allows you to browse for the folder to use or create one At the bottom of the window there is a status indicator and four buttons 4 Service Status This shows the current status of the DatamedRcv DRCVO1 and DatamedRcv_DRCVO1Start services There are three possible values Stopped indicates that both services are not running Running indicates that both services are running and Unknown which indicates that one of the two services is running and the other is not The Unknown status is a normal transition between Stopped and Running however if the status remains in this status then there is a problem The most common reason for this condition is that the security key is not present or accessible If an asterisk appears after the Running label then it means that the DatamedRcv_DRCV01 service is running but the DatamedRcv_DRCVO1Start service is not This condition may be expected for certain secure systems but check with DMESI to confirm that it is correct Start This button will start the services Since DatamedRcv DRCVOIStart is responsible for bringing DatamedRcv DRCVO1 this button actually only starts DatamedRcv DRCVOIStart Stop This button will stop the services Since DatamedRcv_DRCVO01Start is responsible for bringing DatamedRcv DRCVO1 down this button actually only stops DatamedRcv DRCVOIStart Save Changes This button will cause all configuration cha
33. ess File Manager F5 to access a list of EKG files to transmit After selected the desired files press Transmit F4 to send the selected files Chapter 3 Configuring Transmitting Devices Datamed LLC Y Engineering Solutions Inc When using a modem mn Press More F6 then Main Menu then More F6 then System Setup Enter the system password and press Enter Select Basic System and press Select Transmission and press Select Modem Speaker and press then select Dialing Only and press Select Dial tone required and press then select Yes and press Select Dialing method and press then select Tone and press Select Fax error correction and press then select No and press n tw Select 1 Phone Number and press then type in the phone number to reach the modem on the computer where DRCVOI is installed and then press 10 Select Location 1 and press for Type select MUSE Network and press 11 Select Use IR for Serial Line and press then select No and press NOTE this setting may not be present depending on the cart firmware 12 Select Serial Line Baud Rate and press then select 115 2k and press If the maximum setting is less than 115 2k then use the maximum setting available Either settings will work fine with a modem 13 Select Default Location and press then select 1 and press 14 Select Return and press 15 Again select Return and
34. et the Data Console switch to Data Cycle power by disconnecting and then reconnecting the power supply IMPORTANT NOTE If the adapter is rebooted with the Data Console switch set to Console it will not connect to the wireless network successfully Serial transmissions are a continuous data stream whereas TCP IP is a packet based protocol When the SENA adapter receives data from the cardiograph at some point it must decide when the cart is done sending so it can package the data in a TCP IP packet and forward it to the destination This decision is made by using the inter character timeout value This setting is the amount of time in ms that it waits for the next character before deciding that the sending device is done with the message If Chapter 4 Configuring Serial to LAN Adapters Datamed LLC Y Engineering Solutions Inc this value is set too low the adapter may decide the cardiograph is done and send the message prematurely resulting in partial messages being transmitted If this value is set too high then the cardiograph might send two or more messages before the adapter sends the packet Either way the data is not valid and the transmission will fail If the cardiograph repeatedly fails in transmission this parameter should be adjusted up or down Here is example output from the get command for a working configuration Sbatus Serial no LS100W 070100392 MAC address 00 0b 6b 18 ff ff F W REV V1
35. ion in addition to the certificate file private and public keys are required Export the User Client Certificate recognized by the Radius server to a PFX file then use the OpenSSL utility to convert the PFX file into a private key PEM file and a public key PEM file Chapter 4 Configuring Serial to LAN Adapters Datamed LLC Y Engineering Solutions Inc The following screen shows settings for WEP encryption See the instructions below or the Silex manual for more options Click Submit to save the settings Configure Network Security Encryption Mode WEP 128bit 2 Enter the encryption mode Key Selection us Key 1 lt WEP Key Enter the WEP key Key 2 WEP Key 2 Key 83 Note that the Wireless Key 4 Authentication Type is Open even though 3 the access point in Wireless Authentication Type Open System this case Ie Sat to Wired Authentication Type None v WEP Shared Key It aum will not work if set Authentication Attempts 0 to Shared User ID anonymous 2 Password 7 Authentication Protocol PAP PSK SRRRRRRERERERRRERRERERERERERERERERERERERERES 9 Authentication Server Certificate Configure Authentication Server Certificate SSL TLS Private Key Configure Private Key a For WEP encryption set the Encryption Mode to WEP 64 bit or WEP 128 bit Enter the Key Selection and then enter the WEP Key Wireless Authentication must be set
36. n also write filesto an SD card GE MAC 1200 This cardiograph can only transmit through the serial port with or without a modem MAC 1600 This cardiograph can transmit through the serial port with or without a modem through the built in modem if installed or through the built in LAN port if the option is enabled It can also write files to an SD card MAC 3500 This cardiograph can transmit through the serial port with or without a modem through the built in modem if installed or through the built in LAN port if the option is enabled It can also write filesto an SD card GE MAC 5000 This cardiograph can only transmit through the serial port with or without a modem It can also write files to a floppy disk GE MAC 5500 This cardiograph can transmit through the serial port with or without a modem through the built in modem if installed or through the built in LAN port if the option is enabled It can also write filesto an SD card ZOLL E Series prior to rev 4 01 and M Series defibrillators If equipped with the 12 Lead Option this device can transmit through the PC Card modem GE offers a wireless transmission option called MobileLink for the MAC 3500 5000 5500 cardiographs For other devices or if that option is not present a third party serial to LAN adapter can be used to get wired or wireless LAN transmission from the serial interface Starting with version 1 3 0 DRCVOI
37. nges to be saved to the registry Previous settings will be discarded Close This button closes the window Any unsaved changes will be discarded Chapter 5 Configuring DRCVO1 Datamed LLC Engineering Solutions Inc Menu Options The following menu options are available File gt Reload from registry Selecting this will cause any changes to be discarded and the settings on the screen reset to the saved values File Save to registry This is the same as clicking the Save Changes button File Exit This is the same as clicking the Close button Help gt About This will open a window that displays the version information and the license key serial number TCP IP and Serial Listeners Tab This tab contains the settings for TCP IP connections that use a serial to LAN adapter and also for serial connections direct or modem Each setting is described below Note that the settings shown in the screenshots are just sample data Configuration Utility for DatamedRcv DRCVO1 File folder C DatamedF T EKGsfromGE File TCP IP and Serial Listeners Direct Connections Advanced TCP IP Settings Listen for connections on a TCP IP port IP Address of this computer 192 168 111 156 TCP IP Port to listen on 9100 Serial Settings Monitor a serial port for connections Serial port s to monitor com2 Baud Rate 115200 Using modem s on the serial port s Modem init st
38. nning on Windows Vista x64 Windows 7 x64 Windows Server 2003 x64 Windows Server 2003 R2 x64 Windows Server 2008 x64 Windows Server 2008 R2 x64 Serial Connection All compatible cardiographs and devices support a serial connection When using a serial connection either a direct serial cable or modems can be used If using modems both the cardiograph device and the computer running DRCVO1 will require a modem GE typically uses the MultiTech MultiModem ZBA MT5634ZBA modems It is highly recommended that a modem from the same product family MT5634ZBA MT5634ZBA USB MT9234ZBA MT9234ZBA USB be used for DRCVO1 Due to the incompatibilities encountered in testing only the MultiTech modems are supported for use with DRCVO1 IMPORTANT NOTE If a 5232 modem is used as opposed to USB the serial cable must have all control lines connected A oS X TCP IP connection LAN connectivity can be achieved by utilizing a serial to LAN adapter e g Silex SX 500 on the serial port Depending on the adapter either wired or wireless LAN is possible Instructions for setting up these adapters can be found in Chapter 4 Please review the list of network information required If the adapter needs Datamed LLC Y Engineering Solutions Inc Chapter 2 Installation DRCVO1 User s Manual to be powered by the cardiograph instead of an A C power cord a special serial power cable is required For the MAC 5500 cardiographs with built in LAN p
39. ort if the LAN option is enabled on the carts then a direct connection is possible NOTE This application requires the Microsoft NET Framework The setup program will install the Microsoft distribution package if necessary EB Chapter 2 Installation Datamed LLC Y Engineering Solutions Inc New Installation Install the hardware security key If you already have a hardware security key on this computer that is licensed for Datamed EKG Format Translator Software then you will need to update the key with a license for DRCVO1 See Appendix A for instructions If you do not already have a hardware security key that is licensed for Datamed EKG Format Translator Software on this computer then insert the key that was supplied with the software into the USB port The driver should be installed automatically by the operating system If there is a problem with the automatic installation of the driver the drivers can be manually installed after installing DRCVO1 by using the shortcut under Start All Programs Datamed DatamedRcv DRCV01 Install HASP Security Key Drivers Additionally the latest driver may be downloaded directly from the SafeNet Software website at ftp ftp aladdin com pub hasp Sentinel HASP Runtime 928Drivers 29 Sentinel LDK Run time setup zip gt When the driver is properly installed the LED in the hardware key will light up Install the DRCVO1 software On the Software Inst
40. osed in this Product to contact Licensor directly or visit Licensor on the World Wide Web at http www datamed com Appendix C End User License Agreement and Limited Warranty Datamed LLC Engineering Solutions Inc
41. over the 2 pins closest to the red connector labeled 5VDC The picture below shows the jumper in the correct position Reverse the process to reassemble the case and replace the four screws Take special care to prevent damaging the antenna wire Wireless Model S 5 007NYCULO102 007GZCUL0116 FCC ID N6C SX10WG IC 4908A SX10WG e CMII ID 2005DJ1963 silex technology Inc Made in Japan Figure 4 2 Silex J umper Location Whether using wireless or wired LAN the Silex adapter must be configured using the wired port Connect a network crossover cable available at most computer stores from the adapter to a laptop or other computer This will create an isolated network environment To get power either use the A C adapter that came with the Silex or connect the adapter to the cardiograph using the special serial power cable see Chapter 3 for configuration The default configuration on the wired LAN port is for Chapter 4 Configuring Serial to LAN Adapters Datamed LLC Engineering Solutions Inc DHCP however since there is no DHCP server on the isolated network it will default to IP address 192 0 0 192 Set the computer s IP address to 192 0 0 191 subnet mask 255 255 255 0 gateway 192 0 0 1 so that will be able to connect to the Silex adapter Once the Silex adapter is connected to the LAN or directly to a computer use a web browser to go to the adapter s IP address 192 0 0 192 to access the web interface
42. perating systems other than Windows XP On these systems the DatamedRcv_DRCV01Start service will not be able to start and stop the DatamedRcv DRCVO1 service This means that the DatamedRcv DRCVOI service will not start automatically when rebooting Make the following changes to work around the problem In the Services applet modify DatamedRcv_DRCVO01Start to change the startup type to Manual In the Services applet modify DatamedRcv DRCVO1 to 1 change the startup type to Automatic and 2 on the Recovery Tab set all three failure selections to Restart the Service Another step may be necessary if the DatamedFT service still doesn t start automatically after a reboot typically only the Windows Server x64 This can be because the service is trying to start before the HASP driver is fully loaded To fix this you will need to make the DatamedFT service depend on the HASP driver to load Details about this can be found in the following Microsoft Knowledge article http support microsoft com kb 193888 The following steps will set the dependency a Make sure you see Sentinel HASP License Manager in the Services applet If not ensure that the HASP driver is installed properly Open the registry editor regedit and go to LOCAL CurrentControlSet Services DatamedRcv_DRCVO1 Add Multi String value REG MULTI SZ named DependOnService and set the value to hasplms DMESI support can be rea
43. press 16 Select Save Setup and press 17 Select Main Menu and press to get back to the main menu 18 Press File Manager F5 to access a list of EKG files to transmit 19 After selected the desired files press Transmit F4 to send the selected files When using the built in LAN port of a MAC 5500 Press More F6 then Main Menu then More F6 then System Setup Enter the system password and press Enter Select Basic System and press Select Transmission and press Select Default Location and press then select Ethernet MUSE and press Select Return and press DUO UE dx ope pa up Select Network Setup and press Datamed LLC Y Engineering Solutions Inc Chapter 3 Configuring Transmitting Devices DRCVO1 User s Manual 9 10 11 12 13 14 Enter the IP Address Subnet Mask and Gateway address that apply to the cardiograph not the computer running DRCVO1 This information can typically be obtained from the IT System Administrator Then enter the Port Number that will be used by DRCVO1 to connect to this machine If there is a firewall between the cart and the computer then this port will need to be opened This IP Address and Port Number will be used when configuring the Direct Connections tab in DRCVO1 Select Return and press Again select Return and press Select Save Setup and press Select Main Menu and press to get back to the main menu Press File Manager F5
44. re should be transmission information from the testing The following chart can be used to assist in determining the cause of the problem Chapter 6 Troubleshooting Datamed LLC Y Engineering Solutions Inc There may bea problem with the data format Contact ESI Check the baud rate Silex or the inter character timeout SENA 4 LAN Increase the parameter and retry the transmission Long Make test transmission to DatamedRcv with debugging ON Is there data in the debug file Yes Are the data lines short 60 chars or long Short Y The transmissions are not completing What type of connection is being used Serial Check the serial settings If not resolved then contact ESI What type of connection LAN Can you ping the device Yes Y Check the destination IP and port on the device If not resolved contact ESI Make sure the modem answers if used Fix the serial settings and retry the transmission No Resolve the IP issue IP address wireless settings etc and retry the transmission Datamed LLC Y Engineering Solutions Inc Chapter 6 Troubleshooting DRCVO1 User s Manual Important note regarding 64 bit operating systems There are known issues when running on 64 bit o
45. red trademark of Zoom Telephonics Inc MultiModem is a registered trademark of MultiTech Systems Inc Silex Technology is a registered trademark of Nihon Computer Kogyo Kabushiki Kaisha Corporation DISCLAIMER DatamedRcv Model DRCVO1 is produced by Datamed LLC Engineering Solutions Inc and is not endorsed approved sponsored or affiliated with GE Medical Systems Information Technologies Inc Datamed LLC Engineering Solutions Inc TABLE OF CONTENTS Table of Contents 3 Chapter 1 Getting Started 4 Chapter 2 n n n nn 5 Chapter 3 Configuring Transmitting 14 GE MAC 5000 and MAC 5500 5 14 Chapter 4 Configuring Serial to LAN 17 Silex Technology SX 500 Serial to LAN Adapter eeeeeeen nennen nnn 17 SENA HelloDevice Serial to LAN Adapters 24 Chapter 5 Configuring 1 26 TCP IP and Serial Listeners 27 Direct Connections Tab 29 Advanced Tab ped 30 Chapter 6 1 31 Appendix A Updating the H
46. ring AT amp FEORKOSO 1 Service Status Stopped Save Changes TCP IP Settings Listen for connections on a TCP IP port If this box is checked a single TCP IP port will be monitored for incoming connections from carts This will only work with serial to LAN adapters not the built in LAN port When configuring the serial to LAN adapter the IP address and port configured here must be used Datamed LLC Y Engineering Solutions Inc Chapter 5 Configuring DRCVO1 DRCVO1 User s Manual IP Address of this computer This specifies the IP address of the PC that is running DRCVO1 The drop down list should contain all possible addresses Normally there is only a single address in the list but some computers may have more than one Select the appropriate address from the list TCP IP Port to listen on This is the port number that will be monitored for incoming connections This port must not be monitored by any other process and any firewall must be configured to pass data to this port Serial Settings Monitor a serial port for connections If this box is checked or more serial ports will be monitored for incoming connections from carts Serial port s to monitor This list will show all serial ports that are configured on the computer Check any ports that are used to connect to the carts Any number of ports may be monitored but keep in mind that all ports must have the same type of connection i e
47. rmed Installing services gt Once installation is complete click Finish to close the window DRCVO1 tm Setup Installation Successful DRCVUT tm v1 4 0 has been installed successfully Run the DatamedRev DRCVOTConfig utility to update the settings and start the service Please click Finish to exit this installer Einish gt Following installation DRCVO1 must be configured using the DRCVOlConfig configuration utility A shortcut to this utility will be found on the desktop and it can also be found at Start All Programs Datamed DatamedRcv DRCV01 DRCVO1Config After the settings are saved the DRCVOI services can be started immediately by using the Start button An alternative method of starting the service is to open the Services applet from Control Panel Administrative Tools and start the DatamedRcv_DRCVO1Start service The job of this service is to make sure that DRCVO1 runs and is restarted if it stops for any reason Chapter 2 Installation Datamed LLC Y Engineering Solutions Inc Updating If DRCVOI is already installed running DatamedRcv DRCVOI1 Setup exe will update it The settings will not be disturbed To run the update do the following gt Download DatamedRcv DRCVO1 Setup exe from the website contact DMESI for access and double click on it The following screen should appear Click Next to continue DRCVO1 tm Setup Welcome Welcome to the update install
48. s SX 500 Serial Server User s Guide English pdf The Silex adapter can be purchased from a number of retailers e g amazon com The retail package includes a standard A C power adapter In most applications especially when using wireless LAN it is preferable to have the Silex adapter get power directly from the cardiograph through the serial cable This can be accomplished by using a special cable that includes the electronics for supplying power from the cart The cable can be obtained from GE Part 42026825 001 GE also sells a complete kit that includes the Silex adapter the power cable and mounting pieces Part 2034530 001 for USA or 2034530 002 for Europe A compatible cable can also be obtained from Elfin Engineering Part CBL M5K TO SILEX Elfin may be contacted at itronix comcast net Figure 4 1 Serial Power Cable from Elfin Engineering Datamed LLC Engineering Solutions Inc Chapter 4 Configuring Serial to LAN Adapters DRCVO1 User s Manual If power is to be supplied from the cardiograph and the Silex was purchased from a retail source not an internal jumper must be changed Using a 8 screwdriver remove the four 4 small screws around the perimeter of the case one on each side Very carefully separate the top and bottom pieces of the case Using the picture below as a guide locate the 3 pin header in the corner of the PC board labeled J P1 Remove the jumper move it to c
49. s that have occurred Reviewing the log entries will give insight into what is working and what is a problem The first DatamedRcv DRCVO1 message should be Successfully connected to Datamed Security Key Serial Number which shows that the hardware security key is installed properly and the proper license was obtained If the hardware key could not be contacted both DatamedRcv DRCVOI1 and DatamedRcv_DRCV01Start will log Error messages describing the condition In this case make sure that the key is inserted properly and the red light is on The other reason that the services can fail to access the key is due to a licensing problem In this case see Appendix A for instructions for updating the key After the security key message there should be either one or two messages that say that DatamedRcv_DRCVO1 has started listening for message and list the folder where files will be written There is one message for TCP IP connections and one for serial connections so there should one or the other or both depending on the configuration If any message that should be there is not present check the configuration settings using the DRCVO1Config utility to confirm that the parameters are correct If the message is missing and there is no error relating to it it is possible the mandatory field TCPAddress for TCP IP and SerialPort for serial is blank In most cases however there will be an error message that describes the problem Most errors are self explan
50. sure that the correct file appears on the screen and press the Apply update button to update the key Collect Key Status Information Apply Update When the message Update written successfully appears on the screen the utility can be closed The key is now updated The update files can be discarded An important item to note is that the updater utility does not need to be run on the computer that will be the ultimate destination for the Datamed software 36 Appendix A Updating the Hardware Security Key Datamed LLC X Engineering Solutions Inc APPENDIX B REGISTRY SETTINGS If it is necessary to change the settings for DRCVO1 after installation the DRCVO1Config utility should be used There is normally no reason to access the registry editor to make the changes In the event that DMESI support personnel request it you can open the registry editor by selecting Start Run and then type regedit and press OK When the registry editor opens navigate the folders to HKEY_LOCAL_MACHINE SYSTEM CurrentControlSet Services DatamedRcv_DRCVO1 It should look like this amp Registry Editor File Edit View Favorites Help CI Cpaarray Name Data C CRM Client Default value not set a Cryptsve ab Debugging off CJ dac2w2k amp CJ dac96ont 220 DatamedFT amp CJ DatamedFTStart Description Receives ECGs from GE Marquette Cardiographs DirectConnectList REG_MULTI_SZ 192
51. tamedRev DRCV01 to be installed The software will be installed in the folder listed below To select a different location either type in a new path or click Change to browse for an existing folder Install DatamedRev DRCVUT to Program Files Datamed D atamedRicv DRCVOT Change Space required 20 7 MB Space available on selected drive 29 24 GB lt Back Cancel Chapter 2 Installation Datamed LLC Y Engineering Solutions Inc Confirm all of the settings you may go back to correct them and then click Next to begin installing the application DRCVO1 tm Setup Ready to Install You ate now ready to start the installation The installer now has enough information to install DatamedRev DRCVUT on your computer The following settings will be used Install folder C Program Files D atamed D atamedAcy DRCVOT Please click Next to proceed with the installation m Cancel gt The following screens will appear to show the progress of the installation Vb DRCVO1 tm Setup Installing DatamedRcv DRCVOT Please wait Installing Files C Program Files D atamed D atamedRicv DACV01 hasp_net_windows dil Cancel Datamed LLC Engineering Solutions Inc Chapter 2 Installation ER DRCVO1 User s Manual DatamedRcv Model DRCVO1 Setup Installing services and settings Please wait Please wait while the following actions are perfo
52. time setup zip On the key is a light that should be on if the driver is working A standard hardware key is dark purple and a network key is red If this is a network key installation the Safenet HASP License Manager software must be installed or the key will not work This software is on the installation CD Contact DMESI if you need assistance with this If the Security Key still can t be located please contact DMESI support e Symptom The Service Status is stuck on Unknown This status is displayed when the DatamedRcv_DRCVO1Start service is running and the DatamedRcv DRCVOI service is not running Check the Application Event Log to see what messages are there to explain why DatamedRcv DRCVO1 won t start The most likely cause is that it cannot connect to the Security Key See the previous note for steps to make sure the key is working If running on a 64 bit operating system see the notes at the end of this chapter If the services start properly but no files are received when the originating device makes a transmission then the communication needs to be checked DMESI support personnel may need to gather detailed information using the debugging facility If directed to collect debugging information follow the directions to enable debugging in Chapter 5 The debug file s will be created in the output folder and may be examined using any text editor At the top of each file it will describe the connection properties and then the
53. to Open System For DWEP encryption set the Encryption Mode to Dynamic WEP The Wireless Authentication Type can be either LEAP or EAP FAST Enter the User ID and Password For WPA or WPA2 encryption set the Encryption Mode to WPA or WPA2 The Wireless Authentication Type can be LEAP PEAP TLS TTLS EAP FAST or PSK For PSK authentication enter the PSK passphrase otherwise enter the User ID and Password For PEAP or TLS authentication load the Authentication Server Certificate CER file created previously In addition for TLS authentication import the private and public keys PEM files created previously Datamed LLC Engineering Solutions Inc Chapter 4 Configuring Serial to LAN Adapters DRCVO1 User s Manual SENA HelloDevice Serial to LAN Adapters Unlike the Silex adapter which has both wired and wireless LAN the SENA adapters are available only in wired models LS100 LS110 According to SENA the wireless models LSLOOW PS110W PS210W are now discontinued although they can still be found at some sites The configuration is similar for both except for the wireless specific settings Complete information including manuals and data sheets can be found online at http www sena com products device servers hd lite php Follow the instructions in the manual to connect and configure the adapter The wired model can be configured by connecting the LAN and using telnet as described in the manual The best wa
54. ty day Limited Warranty period are not covered by any warranty or condition express implied or statutory 7 YOUR EXCLUSIVE REMEDY Licensor s entire liability and your exclusive remedy for any breach of this Limited Warranty or for any other breach of this EULA or for any other liability relating to the Product shall be at Licensor s option from time to time exercised subject to applicable law a return of the amount paid if any for the Product or b repair or replacement of the Product that does not meet this Limited Warranty and that is returned to Licensor You will receive the remedy elected by Licensor without charge except that you are responsible for any expenses you may incur e g cost of shipping the Product to Licensor This Limited Warranty is void if failure of the Product has resulted from accident abuse misapplication abnormal use or a virus Any replacement Product will be warranted for the remainder of the original warranty period or thirty 30 days whichever is longer and Licensor will use commercially reasonable efforts to provide your remedy within a commercially reasonable time of your compliance with Licensor s warranty remedy procedures Licensor may use electronic means to deliver the product To Appendix C End User License Agreement and Limited Warranty Datamed LLC Engineering Solutions Inc exercise your remedy contact Engineering Solutions Inc 7755 Hunters Run Drive Germantown TN 38138 U
55. ure IP Access Control m DNS Configure DNS Datamed LLC Y Engineering Solutions Inc Chapter 4 Configuring Serial to LAN Adapters DRCVO1 User s Manual If the wireless capability will be used click on Wireless in the left sidebar menu to bring up the Configure Wireless screen The important changes are described below Click Submit to save the settings Configure Wireless Choose the mode J Dynamic Frequency Select Disabled v Mode INFRASTRUCTURE 7 typically Infrastructure Radio 802 11b g 2 SSID 1 lt 5510 Values di Enter the SSID Network Security Configure Network Security Click here to sat up 11 9 wireless security Speed 54 y International Roaming Flexible zzz Select the Country United States b 2 appropriate country Signal Quality Disable RTS Threshold 2432 To configure the security settings click on Configure Network Security in the Configure Wireless screen The network administrator will supply the necessary security information needed If using PEAP or TLS authentication a certificate file will be needed This file is generated on the Server Certificate Authority recognized by the Radius server On the server open Control Panel Internet Options choose the Content tab and press the Certificates button Choose the Trusted Root Certification Authorities and locate the server s CA Select the CA and export it to a CER file If using TLS authenticat
56. ve and other equitable relief without bond and without the necessity of showing actual money damages 5 TERMI NATI ON Without prejudice to any other rights Licensor may terminate this EULA immediately and without notice if you fail to comply with any term or condition of this Agreement Upon such termination you must immediately destroy all complete and partial copies of the Product including all backup copies Sections 8 9 10 11 13 14 and this Section 5 shall survive any expiration or termination of this Agreement 6 LIMITED WARRANTY FOR PRODUCT Licensor warrants that the Product will perform substantially in accordance with the documentation thereof for a period of ninety 90 days from the date of receipt Extended warranty support may be available for purchase from Licensor If an implied warranty or condition is created by your state jurisdiction and federal or state provincial law prohibits disclaimer of it you also have an implied warranty or condition BUT ONLY AS TO DEFECTS DISCOVERED DURING THE PERIOD OF THIS LI MI TED WARRANTY NINETY DAYS AS TO ANY DEFECTS DISCOVERED AFTER THE NINETY DAY PERIOD THERE IS NO WARRANTY OR CONDI TI ON OF ANY KI ND Some states jurisdictions do not allow limitations on how long an implied warranty or condition lasts so the above limitation may not apply to you Any supplements or updates to the Product including without limitation any updates provided to you after the expiration of the nine
57. y to configure the wireless model is to connect the serial port to a computer set the Data Console switch to Console and then use a program such as HyperTerminal to access the serial console as described in the manual Either method LAN or serial will result in a text based interface for configuration Use the get command to see the current settings The following are the important settings to configure substitute IP address as appropriate The default setting is to use DHCP for an IP address If a static IP address is required use set ip static 192 168 1 12 255 255 255 0 192 168 1 1 To set it to DHCP instead use set ip dhcp gt setup the destination IP information use set host tcpc 192 168 1 13 To set the serial parameters use set serial 9600 8 n 1 h h n 200 Note that many of the carts that require the use of the SENA adapter only support 9600 baud The last parameter on the command line is the inter character timeout which is crucial and may need to be adjusted higher if it is transmitting partial sequences See the technical discussion below for more details on this setting Forthe wireless model the wlan settings must be configured For 128 bit WEP security use set wlan SSIDi 112 a WEPKEY There are a number of options see the manual for a complete description of this command Use get to check the settings and once the setting are correct use save to store them If using the serial console s