1. Software is also provided with the GM FTTX 1000 Kit and GM FTTX 500 to permit the extraction of 5 frames from the MPEG video file that can be converted to JPEG or BMP format for inclusion within an a word of other document form User Manual N o GM FTTX 1000 3 March 2009 18 Standard Parts List Following parts have been included in the GM FTTX 1000 kit FTTX Fibre Eye Video Probe 2 5 inches diagonal monitor amp battery pack fitted inside SD Memory Card Universal 2 5mm tip GM FTTX PC2 5 AC battery charger User manual CleanCore Cassette Excluded On GM FTX 500 CleanCore Replacement Cartridge Excluded On GM FTTX 500 Excluded On GM FTTX 500 1 25mm FerruleMate Or US Conec Or CleanZone Cleaner Exclu ded On GM FTTX 500 2 5mm FerruleMate Or US Conec Or CleanZone Cleaner Excluded On GM FTTX 500 Case Replaced With Black Soft Bag With Shoulder Strap FOR GM FTTX 500 N B CleanZone not sold into North America Optional Items Interchangeable tips Patch cord In adaptor to suit your applicati on may be purchased separately Please contact a GM Optics Limited representative for a full list of connectors supported In addition there exists and option to purchase 2 5mm and or 1 25mm US Conec In adaptor cleaner Inserts are available for standard case to receive both units Maintenance Every attempt has been made to make your instrument as rugged as possible However due to the precision in optical am
2. Record key on the display keypad and the viewed image will be stored to selected storage medium in a MPEG file See illustration below Press back or enter key to stop recording To view stored images press BACK key on keypad This takes user out of the screen that permits a real time image of ferrule end face to be viewed to the following screen Move Left Right Cursor Keys Until Playback Image Displayed Then Press Enter With Playback screen selected the user will be presented with the following screen that provides the user with a summary of the images that have been stored By selecting a stored image with the Up Down cursor keys on the keypad then pressing the enter key once the image will be played for a short period of time before moving through the stored image list to the next stored image Press back to stop scrolling and to return to screen showing stored images Images can be deleted by pressing the menu button Copy or delete options will appear on the screen To delete an image move cursor to the image to be deleted press enter and then select yes with up down cursor keys to the question Delete This Document To leave screen press Back once User Manual No GM FTTX 1000 3 March 2009 11 a E D Oo P T GYS Stored Images MPEG AVI Files Setting Up The Correct Time And Date The user is reguired to select the Setting function by moving the cursor key as illustrated below to Setting and then p
3. instrument Failure to comply with these precautions or with specific warnings elsewhere in this manual violate standard of design manufacture and intended use of the instrument User Manual No GM FTTX 1000 3 March 2009 20 Before operating review the instrument and m anual for safety making and instructions You must follow these to ensure operation and to maintain the instrument in safe condition Power supply The microscope receives power via the supplied battery pack assembly To recharge the battery pack the unit reguires a standard 120V 240V 50 60 Hz power outlets Recharging takes approximately 6 5 hours if the battery is fully discharged Current model of battery pack monitor has a 10096 operational time of approximately 8 hours Operating Environment The FTTX Fibre Eye can be operated at temperatures between 0 Celsius to 50 Celsius and at relative humidity of max 95 non condensing Storage and shipment The FTTX Fibre Eye can be stored or shipped at temperature between 20 Celsius and 70 Celsius and at relative humidity of between 10 96 and 9596 non condensing Protect the unit from temperature extremes that may cause condensation within it WARNINGS DO NOT perform electrical tests when there is any damage to any portion of outer closure You must return malfunction instrument to your local agent for forwarding for repair and calibration Please include your contact details amp clearly stat
4. D CARD N B User can lock keyboard if reguired by selecting Off on the following switch Key Lock Switch OFF OM KEY LOCK User Manual No GM FTTX 1000 3 March 2009 a l patchcords while only using the users two hands the G M FTTX 500 offers an option to mount the video probe directly onto the side of the battery pack monitor as illustrated below The probe has a side mounted bracket which clips into the dedicated slide clip on the side of the probe To release the probe the spring level should be pushed in and the probe pulled down the slide until fully disengaged ideo Probe Mounted Onto Battery Pack Monitor Video Probe Bracket Monitor Slide User Manual No GM FTTX 1000 3 March 2009 17 The user can connect the battery pack monitor directly to an external PC through the use of the USB port as illustrated below With the USB cable as supplied connected to both the USB port on the battery pack monitor and PC the screen on the monitor will can to a fixed display message which will state PC CONNECTION MASS STORAGE To directly access stored images user will need to go to MY COMPUTER and click on removable disk relevant to storage device held within battery pack monitor As previously detailed the user records audio with video when operating in the record mode The audio level is controlled by adjusting the on screen volum e indicator through the use of the keypad up down keys
5. EUROPEAN PARLIAMENT AND OF THE COUNCIL of 27 January 2003 on the Restriction of the use of Certain Hazardous Substances in Electrical and Electronic Equipment RoHS User Manual No GM FTTX 1000 3 March 2009 O P T 1 CE Introduction amp application The GM FTTX 1000 GM FTTX 500 At a Glance The FTTX 1000 Kit has been developed to provide end users with a comprehensive and effective field portable solution for clean and inspection of optical interfaces The video microscope provides the capability to inspect the end face of a fibre optic connector Patch cord and Insitu F O connectors for scratches contamination and other defects Contamination of a fibre optic port on an active device or on a patch panel can be inspected with this handheld video microscope allowing cleaning to take place where contamination is confirmed before failure of the interface network connection occurs In addition to inspecting fibre optic ports the video microscope can be used to inspect patch cords and bare 1 25mm and 2 5mm ferrules The is a video inspection probe with a simple userfriendly focusing amp display system It offers users a stable repeatable high resolution image permitting detection of lt 1 25 micron scratches and contamination on a ferrule end face viewable down to 0 5 microns wh ether in the bulkhead or as a free connector It has approx 340 microns horizontal field of view and a 260 micron vertical field of view which allo
6. age medium is selected from the Setting screen discussed later in this user manual Press the Record key on the display keypad and the viewed image will be stored to selected storage medium in a MPEG file See illustration below Press back or enter key to stop recording To view stored images press BACK key on keypad This takes user out of the screen that permits a real time image of ferrule end face to be viewed to the following screen Move Left Right Cursor Keys Until Playback Image Displayed Then Press Enter Playback With Playback screen selected the user will be presented with the following screen that provides the user with a summary of the images that have been stored By selecting a stored image with the Up Down cursor keys on the keypad then pressing the enter key once the image will be played for a short period of time before moving through the stored image list to the next stored image Press back to stop scrolling and to return to screen showing stored images Images can be deleted by pressing the menu button Copy or delete options will appear on the screen To delete an image move cursor to the image to be deleted press enter and then select yes with up down cursor keys to the question Delete This Document To leave screen press Back once User Manual No GM FTTX 1000 3 March 2009 SB Drive Memory storage medium is selected from the Setting screen discussed later in this user manual Press the
7. ation however it is recommended to align the individual tip coding in the position as shown below with the probe mounting clip on the left hand side of the probe as viewed from the top of the probe for 2 5 patchcord 1 25 patchcord ST PC LC MU PC SC FC PC in adaptors User Manual No GM FTTX 1000 3 March 2009 7 O P T TE Illustration Of Tip Assembled Onto Nose Of Video Microscope Probe User should ensure that the adaptor tip is properly aligned amp has been pushed fully into the nose before tightening screw as indicated Do not over tighten screw bush Apply light finger pressure only N B Over tightening will caused the displayed image to become offset from its normal position Misalignment or loose assembly of the adaptor tip onto the probe nose could potentially result in a poorly illuminated non central image of the ferrule end face being displayed on the stand alone monitor Switch on power from battery pack monitor unit as shown Power On Off Switch User Manual No GM FTTX 1000 3 March 2009 8 With the display turned on select the magnificat ion symbol from the symbols displayed on the main menu screen by using the left right arrow keys on the keypad When correctly selected the magnification glass symbol will be highlighted in light blue Press enter See illustration below Check Up Select the FTTX Fibre Eye video probe to be used With the video probe plugged into the input port
8. e the problem requiring attention The GM Optics Limited Fibre Optic Clean And Inspection Kit Solution User Manual No GM FTX 1000 3 March 2009 21 Product Guarantee The buyer of this product should inspect the goods upon arrival and within five 5 business days should notify GM Optics Limited of any conditions which may prevent the acceptance of this product In the event of a claim appropriate measures will be taken to investigate the cause Claims must be made in accordance to the conditions stated in the Standard Terms and Conditions of Sale Shipping Information All items are packed in a secure fashion so as to prevent an y damage during transit Product Guarantee The buyer of this product should inspect the goods upon arrival and within five 5 business days should notify GM Optics Limited of any conditions which may prevent the acceptance of this product In the event of a claim appropriate measures will be taken to investigate the cause Claims must be made in accordance to the conditions stated in the Standard Terms and Conditions of Sale Warranty GM Optics Limited warrant this product to be free of defects in workmanship and materials for a period of 1 year after purchase This warranty excluding batteries is solely limited to the repair and replacement of original parts which are defective in workmanship of materials All other costs should be the sole responsibility of the owner This warranty does
9. he latter being via the USB 2 0 port Image files are stored in MPEG format with audio Once the SD Memory card is inserted there are no other connections reguired for storage before the user is able to commence operation SD Memory Card User s Manual No GM FTTX 1000 3 March 2009 6 O P T OU MM VN WL D Simple Operation Connect the 4 pin connector of the probe to the display unit as shown below User has a choice of selecting either CH1 or CH2 input port The stand alone battery pack monitor can support two independent video probes simultaneously CH1 and CH2 connectors with 1 probe being available to inspect patchcord and the second in adaptors while also providing a facility for an external video monitor V Out to be directly connected to the battery pack monitor Using the display function with the menu driven software the user selects whether the real time image is to be displayed on the free standing 2 5 inch TFT display or an external NTSC PAL monitor OFF ON KEY LOCK Select correct adaptor tip from adaptor box contained inside the carry case The adaptor tip is screwed onto the nose of the probe through the use of the moveable threaded collar on the probe nose User should ensure that the adaptor tips are assembled onto the nose with the adaptor tip key way in the correct orientation for the connectors to be inspected APC connectors The remaining PC UPC Patchcord in adaptor tips can be used in any orient
10. not cover any defects damage and deterioration due to misuse alteration or negligence User Manual No GM FTX 1000 3 March 2009 22
11. o P T i CE USER S MANUAL For Either FTTX Fibre Eye Clean And Inspection Kit Model GM FTTX 1000 Or GM FTTX 500 Revision 3 3 March 2009 User s Manual No GM FTTX 1000 3 March 2009 WELCOME NOTE Congratulations on your purchase of this kit stand alone video microscope which has been developed to provide the best reliability and performance To get the best use of the eguipment contained within the kit video microscope amp ensure its safe operations please take a few minutes to read this manual User Manual No GM FTTX 1000 3 March 2009 O P T CHH EWI TED Disclaimer The information noted within this document is purely for informational purposes only Please note that GM Optics Limited do not warrant or assume any legal liability or responsibility for the accuracy completeness or usefulness of any information or processes disclosed Specifications are subject to change without notice The following information is strictly confidential Reproduction or disclosure to any third party is not permitted without the express written consent of GM Optics Limited For further information or general comments please contact one of our sales offices Range Of Limitations The Product Information found herein pertain to the CleanZone Part Number SCK CZ 250 125 Dimensions and Materials All the materials comply with RoHS Restricted Hazardous Substances as detailed in DIRECTIVE 2002 95 EC OF THE
12. of choice CH1 CH2 on the battery pack monitor the user is required to select the correct video channel to be viewed by pushing CH1 CH2 on the keypad thereby toggling between each available channel Press Key To Scroll Through CH1 or CH2 Video Channel User Manual No GM FTTX 1000 3 March 2009 The selected channel will be displayed on the top left hand corner namely either CH1 or CH1 along with date and time on the top right hand corner and battery indicator level in the bottom left hand corner The ferr ule end face being viewed via the selected channel will also be displayed on the stand alone battery pack monitor Bring the image being displayed into focus by adjusting the focus wheel N B Focusing Wheel The unit is supplied with the facility to adjust the displa yed image brightness contrast or colour through use of the keypad Press Enter Key With Image Being Displayed The Following Screen CHI Gi A 19 20 94 Will Appear Over The Ferrule End Face Image Using Up And Down Keys on keypad Select Contrast Contrast SE a pre Brightness And Or Colour With Selection Completed Use Left And Right Keys on keypad To Adjust Press Enter To Return To Close Screen User Manual No GM FTTX 1000 3 March 2009 a SB With ferrule end face being displayed the user can capture an image of the ferrule end face to either a NandFlash SD Memory Card or an Eter nal Hard Drive Memory stor
13. p mechanical assembly this User Manual No GM FTTX 1000 3 March 2009 19 eguipment may be damaged by physical abuse Please DO NOT attempt to access the internal parts of the FTTX Fibre Eye for cleaning Under no circumstances should you attempt to adjust security screws settings found either side of probe housing There are no user serviceable parts inside The instrument is pre set at factory The only part of video microscope probe that may require cleaning is the outer surface of the objective lens and the threads onto which the individual adaptor tips are screwed If gross contamination becomes evident on the objective lens use the following cleaning procedure Take a cleaned cotton swab or a CLETOP stick or similar Slightly moisten with lab grade alcohol then gently clean outer surface of the lens Use another clean cotton swab to wipe off excess alcohol and allow the lens to evaporate any remaining alcohol To clean threads remove the adaptor tip until it is fully removed Take a soft brush and clean the threads Please contact a GM Optics Limited representative for further details if reguired Service amp Support Oualified personnel must perform any adjustment maintenance or repair of this product Contact your customer support Engineer though your local GM Optics Limited agent Safety Precautions The following general safety precautions must be observed during all phases of operations services and repair of the
14. ressing the enter key once Select System Time Setting from the System Setting display by moving cursor with up down left or right keys on keypad Once selected press enter User Manual No GM FTTX 1000 3 March 2009 13 o P FT ja Using the keypad arrow keys adjust date and time as displayed Press Back to leave screen system Setting As can be illustrated above by selecting individual functions from the menu the user can change brightness Independent of on screen real time image variations describe above change user interface language to either Chinese or English change display setting output to TV_PAL TV_NTSC or LCD As illustrated below Format key permits you to access the storage medium and erase all files through a single operation if required Function selection in all cases is via keypad arrow keys and enter key Display Output Setting User Manual No GM FTTX 1000 3 March 2009 13 If the user wants to confirm that memory status of the selected storage medium then by selecting Memory Status function on Setting screen and pressing enter once the user enters the following screen Format If the user selects SC Card then the following display would be presented User Manual No GM FTTX 1000 3 March 2009 15 Shutdown procedure FTTX Fibre Eye Switch off FTTX Fibre Eye using power switch as indicated below Hold for approx 3 seconds until displayed shuts down S
15. ws inspection of the whole 260 microns ferrule contact zone The probe s shielded cable is terminated with a 4 pin connector The cable provides the power supply to the video microscope CCD and associated electronics and carries the composite video signal to the portable monitor battery assembly User s Manual No GM FTTX 1000 3 March 2009 4 O P T VM em TED Specification Display 2 5 composite video TFT Video Format NTSC Resolution Inspection contamination lt 1 25 Microns 0 5 microns viewable Magnification Approx x150 x200 and x400 Options Available Field of view Approx 260 x 340 microns Approx 420 Diagonal Battery Built in Re chargeable Li ion battery gt 8 Hours 100 Operation Charging time 6 5 hours max Operating Temperature O to 50 Degree Celsius Storage 20 to 70 degree Celsius User Manual User s Manual No GM FTTX 1000 3 March 2009 Initial Set up Remove the Video Microscope probe and battery monitor unit from the carry case N B Check that the battery pack unit is FULLY charged UNIT CAN NOT BE OPERATED WHILE UNDER CHARGE TYPICAL CHARGE TIME 6 5 HOURS Remove the SD Memory Card from its plastic case and insert into the slot as shown by the image below The FTTX Fibre Eye video microscope utilises the SD Memory Card as one of the image storage options Alternatively the user could select via the menu driven software either the internal NandFlash or external HD t