1. Must be recycled Properly Any Electrical or Electronic Equipment EEE component or assembly of parts intended to be incorporated into EEE devices as defined by European Directive 2002 95 EEC must be recycled or disposed using techniques that do not introduce hazardous substances harmful to our health or the environment as listed in Directive 2002 95 EC or amending legislation Battery disposal in Landfill Sites is more regulated since July 2002 by regulation 9 of the Landfill England and Wales Regulations 2002 and Hazardous Waste Regulations 2005 Battery recycling has become topical and the Waste Electrical and Electronic Equipment WEEE Regulations are set to impose targets for recycling Adam Equipment Company 2012 ADAM EQUIPMENT is an ISO 9001 2008 certified global company with more than 40 years experience in the production and sale of electronic weighing equipment Adam products are predominantly designed for the Laboratory Educational Health and Fitness retail and Industrial Segments The product range can be described as follows Analytical and Precision Balances Compact and Portable Balances High Capacity Balances Moisture analysers balances Mechanical Scales Counting Scales Digital Weighing Check weighing Scales High performance Platform Scales Crane scales Health and Fitness Scales Retail Scales for Price computing For a complete listing of all Adam products visit our website
2. This can only be done before or after a weighing takes place 5 4 HEIGHT UNITS To change the displayed height measuring unit press the cm ft key which will then cycle you through the available options of height measuring units This can only be done before or after a weighing takes place 7 Adam Equipment Company 2012 5 5 WEIGHING HEIGHT BMI To determine a person s weight height and BMI the patient should stand on the platform within the marked area and look straight ahead The ultrasonic sensor will detect that a person is on the platform signified by the symbol in the upper right part of the display and start to determine the height When a stable reading of weight is obtained the three readings will be displayed Hold BOUT 1 218 The results will remain on the display until the Clear key is pressed Results from a BMI measurement can be determined as the table below BMI Weight Status Below 18 5 Underweight 18 5 24 9 Normal 25 0 29 9 Overweight 30 0 and Above Obese 8 Adam Equipment Company 2012 5 6 PRINTING AND OUTPUTTING THE RESULTS If a printer or other data collection device is being used the results will be sent automatically or manually depending on the printing control set up The data transmission speed must be set correctly to allow the results to be received The Doctor and patients identity number can be programmed into the Indicator to give you a traceable record whi
3. then kg Ib to select the next parameter 6 3 SETTING THE PRINTING CONTROLS SER The MUW can be set to automatically print AUTO or print on demand PrN by pressing the Print button The data transmission speed Bps of the MUW must match that of the Printer or other device being used to collect data information successfully The printing control and speed can be selected as follows 1 Switch on the scale then press the kg Ib key during the self checking test of the display 2 The display will show the first function FIEL 3 Press the kg Ib key to select 2 then Zero to enter and show the current printing control setting UArt 4 Either printing on demand PrN pressing the Print key following a weighing or printing automatically AUTO automatically prints out when a stable reading and BMI calculation is displayed can be selected 11 Adam Equipment Company 2012 5 Press the Print key to change the setting for the printing control and press Zero to save 6 The current setting for data transmission speed Bps will now be displayed 600 1200 2400 4800 9600 are available Default is 9600 Press the Print key to change the setting and press Zero to save Test will be displayed press the Print key to send a test print command 7 Press Zero to save cm ft to exit then kg Ib to select the next parameter 6 4 PRINTING DETAIL CONTROL F4 PrSEL The MUW can be program
4. and the scale will return to Zero A print out with date and time can be issued following every calibration If an error code was displayed when calibrating please see the error code table in section 9 1 15 Adam Equipment Company 2012 8 0 SERIAL INTERFACE SPECIFICATIONS The balance comes equipped with an RS 232 Serial Interface The connector is a DE 9P female fitting with the following connections Pin2 TXD Transmitted data Pin 3 Received data 5 GND Signal ground Printing Output The lines will include a heading for each detail then the value A typical output when weighing is shown below 6 lines of data are printed if all are enabled All lines end with a carriage return cr and a line feed If OdH and OaH in ASCII Doctor Id 00001 Patient Id 0000000123 Weight 80 00 kg Height 183 cm BMI 23 9 D amp T 30 07 2012 11 20 Input command format The balance can be controlled by a PC with the following commands The commands must be sent in upper case letters i e T not t Z lt cr gt lt lf gt Will Zero the scale performs the same functions as pressing the Zero key P lt cr gt lt lf gt Will send a Print command to a PC or Printer Performs the same functions as pressing the Print key C lt cr gt lt lf gt Will clear the last recorded reading from the display Performs the same functions as pressing the Clear key W lt cr gt lt lf gt Will change the Weight me
5. available on our web site 18 Adam Equipment Company 2012 CE Manufacturer s Declaration of Conformity This product has been manufactured in accordance with the harmonised European standards following the provisions of the below stated directives Electro Magnetic Compatibility Directive 2004 108 EC Low Voltage Directive 2006 95 EC Adam Equipment Co Ltd Bond Avenue Denbigh East Milton Keynes MK1 1SW United Kingdom FCC COMPLIANCE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment The equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Shielded interconnect cables must be employed with this equipment to insure compliance with the pertinent RF emission limits governing this device Changes or modifications not expressly approved by Adam Equipment could void the user s authority to operate the equipment WEEE COMPLIANCE Sealed Lead Acid Battery
6. E mPI See section 6 7 Setting the date and time F8 SETUP See section 6 8 Set up parameters F9 TECH Service only 6 1 SETTING THE BACKLIGHT OPERATION The backlight function can be set by the user AUTO Sets the backlight to operate automatically when a weight is placed on the platform or a key is pressed Sets the backlight to be on at all times Sets the backlight to be off at all times 1 Switch on the scale then press the kg Ib key during the self checking test of the display 2 The display will show the first function FIEL 3 Press the Zero key to select show the current setting default is AUTO 4 Press the Print key to change the setting for the backlight and press Zero to save then kg Ib to select the next parameter 10 Adam Equipment Company 2012 6 22 SETTING AUTO OFF F2 An automatic power down time can be set so that the MUW turns off after a period where no activity is detected This preserves the life time of the battery when used in this mode Settings are OFF 5 10 20 and 30 minutes 1 Switch on the scale then press the kg Ib key during the self checking test of the display 2 The display will show the first function FEL 3 Press the kg Ib key to select F2OFF and then Zero to enter and show the current setting default is 10 4 Press the Print key to change the setting for the backlight and press Zero to save
7. Ib 0z 8888 B HBOBBB Max 300kg 660Lbs MUW 300L d 0 05kg 0 1L bs Print nt C Zero Clear Tare Symbol Ultrasonic Sensor Symbol 5 Adam Equipment Company 2012 KEYS PRIMARY FUNCTION SECONDARY FUNCTION To turn the scale On or Off clear To clear the readings on the display ready for the next weighing t To change the displayed height To save and escape back to the em tt reading between cm feet or feet and parameter settings inches To send a command to print the To change the setting when in a USER current displayed readings parameter To change the displayed weight To change the USER parameter reading between Lb s or Lb s and Ounces Zero To Zero the scale before weighing To enter the selected setting whenina To Tare any item to obtain net weight USER parameter 4 1 REAR PANEL The rear panel has a connector input for the external power adaptor 12 volts DC 800ma 4 2 INTERNAL RECHARGEABLE BATTERY The scale can be operated from the internal rechargeable battery or using an adapter The battery life is approximately 24 hours with the backlight off Depending on the usage of the backlight the lifetime of the battery will reduce The display will show an indication when the battery needs to be charged To charge the battery plug the
8. This document hosted by www oldwillknottscales com ADAM Adam Equipment MUW HEALTH AND FITNESS SCALE USER MANUAL P N 7 00 6 6 0229 Revision A July 2012 1 Adam Equipment Company 2012 CONTENTS NS INT NT sia ea ci a De va 2 05 INTRODUC TION A cule teeta te 2 1 UNPACKING AND SETTING UP YOUR 3 3 0 LOCATING AND PROTECTING YOUR SGALE 4 4 0 KEYPAD DISPLAY FUNCTION isi 5 VA BHEARCPANEL x d eno tt i t pdt EO tiii Rte prop 6 4 2 INTERNAL RECHARGEABLE BATTERY sse 6 5 07 BASIC OPERATION D uto la eae al tay 7 5 1 SWITGHING THE BALANCE ON ey senex 7 52 ZEROING anini cae tetra Cea alec ccna deta elcid wala 7 53 WEIGEINGCUNITS PODES Indore 7 54 HEIGHT UNITS c 7 5 5 WEIGHING HEIGHT BMI co OE desea p iet 8 5 6 PRINTING AND OUTPUTTING THE RESULTS etri a e tete 9 5 7 CLEARING A PREVIOUS RESULT eiit ot te eet eee gun conces 9 6 05 PARAMETERS cem ae a a dal dic or eot unis 10 61 SETTING THE BACKLIGHT OPERATION 10 62 SETIHNGAUIOOFF I UIT eoo re DOS dos e
9. adapter into the POWER input socket in the rear panel and connect it to the mains power supply The charging indicator in the lower left corner of the LCD will be on to show it is charging and will turn green when the battery is fully charged 6 Adam Equipment Company 2012 5 0 BASIC OPERATION 5 1 SWITCHING THE BALANCE ON Plug in the unit using the adapter or use the internal rechargeable battery It is recommended that you charge the battery for at least 8 hours before first use 1 To turn on press the On Off key once and release The scale will show the software revision the battery voltage and then a self test before showing the stable sign and zero weight on the display 2 The scale can now be used 3 To turn the scale off after use press the On Off key again There is an auto power off function that will automatically turn the unit off if not used for a period of time This can be set in the parameters section 6 0 5 2 ZEROING You can press the Zero key to set a new zero point and show a zero reading This may be necessary if the weight reading is not indicating zero with nothing on the platform and should be done if required before each new weighing takes place The zero indicator will show up in the upper left corner of the LCD when the scale displays Zero 5 3 WEIGHING UNITS To change the displayed weighing unit press the kg Ib key which will then cycle you through the available options of weighing units
10. asuring unit being used between kg lbs and 165 and ounces Performs the same functions as pressing the kg Ib key H lt cr gt lt lf gt Will change the Height measuring unit being used between cm inches and feet and inches Performs the same functions as pressing the cm ft key 9 0 TROUBLE SHOOTING 16 Adam Equipment Company 2012 9 1 ERROR MESSAGES If an error message is shown repeat the step that caused the message If the error message is still shown then contact your dealer for support DISPLAYED MESSAGE DESCRIPTION Err Measured height is above 210cm 82 5 inches UNDER Measured height is below 80cm 31 5 inches Err H Calibration weight value used too high Err L Calibration weight value used too low 255555 Weight on top exceeds 300kg 660Lbs 10 0 TECHNICAL SPECIFICATIONS Model MUW 300L Maximum Capacity 300kg 660Lbs Readability 0 05kg 0 1Lbs Repeatability s d 0 1kg 0 2Lbs Linearity 0 1kg 0 2Lbs Units of Height Cm inches feet and inches Height range 80cm 210cm 31 5 82 5 inches Units of Weight Kg Ib s Ib s and ounces Power Supply 12vDC 2800ma or Internal rechargeable 6vDC battery Overall Dimensions 0 38m x 0 6m x 2 3m wxdxh 15 x 23 6 x 90 2 inches 17 Adam Equipment Company 2012 11 0 WARRANTY INFORMATION Adam Equipment offers Limited Warranty Parts and Labour for the components failed due to defe
11. at www adamequipment com Copyright by Adam Equipment Co Ltd All rights reserved No part of this publication may be reprinted or translated in any form or by any means without the prior permission of Adam Equipment Adam Equipment reserves the right to make changes to the technology features specifications and design of the equipment without notice All information contained within this publication is to the best of our knowledge timely complete and accurate when issued However we are not responsible for misinterpretations which may result from the reading of this material The latest version of this publication can be found on our Website www adamequipment com Adam Equipment Company 2012
12. ch also records date and time To enter the Doctors Id press and hold the Print key for 2 seconds The display will show as below use the Print and Clear keys to move the flashing digit and the kg Ib and cm ft keys to enter the Id number you require and press Zero to save The display will now show the Patients Id screen use the keys as above to set the Id number and press Zero to save and exit back to normal weighing dr Id 00001 See section 6 3 and 6 4 for printing controls and data transmission speed options 5 7 CLEARING A PREVIOUS RESULT Once the results have been calculated and displayed they will remain displayed until the Clear key is pressed When the patient has stepped off the platform and the results have been recorded or printed the Clear key can then be pressed which will return the display to zero ready for the next patient to be weighed 9 Adam Equipment Company 2012 6 0 PARAMETERS The balance has 8 parameters where options can be set by the user FUNCTION SECTION DESCRIPTION FIEL See section 6 1 Sets the backlight operation Default is AUTO FZ OFF See section 6 2 Auto off function Default is 10 FJSER See section 6 3 Sets the printing control and data transmission speed Default is 9600 HPrSH See section 6 4 Printing controls F5 ULTRA See section 6 5 Calibration of the height sensor F6 HOLD See section 6 6 Sets the HOLD function to ON or OFF
13. cts in materials or workmanship Warranty starts from the date of delivery During the warranty period should any repairs be necessary the purchaser must inform its supplier or Adam Equipment Company The company or its authorised Technician reserves the right to repair or replace the components at any of its workshops depending on the severity of the problems However any freight involved in sending the faulty units or parts to the service centre should be borne by the purchaser The warranty will cease to operate if the equipment is not returned in the original packaging and with correct documentation for a claim to be processed All claims are at the sole discretion of Adam Equipment This warranty does not cover equipment where defects or poor performance is due to misuse accidental damage exposure to radioactive or corrosive materials negligence faulty installation unauthorised modifications or attempted repair or failure to observe the requirements and recommendations as given in this User Manual Additionally rechargeable batteries where supplied are not covered under warranty Repairs carried out under the warranty does not extend the warranty period Components removed during the warranty repairs become the company property The statutory right of the purchaser is not affected by this warranty The terms of this warranty is governed by the UK law For complete details on Warranty Information see the terms and conditions of sale
14. dJUST XX XX being a factory set figure 4 Press the Zero key and the display will show base H 220 press Zero to calibrate the Zero height reading 5 The display will show test and a 4 digit number Press the Zero key from a position where the height sensor cannot detect you 6 When calibration is complete the display will Show AdJUST XX If after calibration the height sensor is not measuring correctly press Print or Clear at point 3 to change XX A lower number will decrease the height measurement and a higher number will increase it Then continue from point 4 on A print out with date and time can be issued following every calibration 6 6 SETTING THE HOLD FUNCTION FG HOLD The Hold function can be set so that the height and BMI readings are visible as they are being calculated OFF or remain as dashes until the weight reading is stable upon where they will be displayed ON 1 Switch on the scale then press the kg Ib key during the self checking test of the display 2 The display will show the first function FIEL 3 Press the kg Ib key to select F6 MOLD and then Zero to enter and show the current setting default is ON 4 Press the Print key to change the setting for Hold press Zero to save then kg Ib to select the next parameter 13 Adam Equipment Company 2012 6 7 SETTING DATE AND TIME 70 7 1 Switch on the scale then press the kg Ib key during the self checking test o
15. f the display 2 The display will show the first function FJL 3 Press the kg Ib key to select Z7ZJ Zand then Zero to enter the date setting display 4 The display will show the day month and year 5 To change any setting press the kg Ib key to increment the flashing digit and either the Print or Clear key to move the flashing digit to the left or right 6 Press the Zero key to save the date and enter the time setting parameter 7 To change the time press the kg Ib key to increment the flashing digit and either the Print or Clear key to move the flashing digit to the left or right 8 Press Zero to save cm ft to exit then kg Ib to select the next parameter 6 8 SETUP F8 SETUP Four performance parameters Filter Auto Zero Stability and weight tracking are available to the USER These parameters influence the speed of the display update and have been factory set the default settings should normally be used to optimise performance Available parameters and settings are as below PARAMETER DESCRIPTION DEFAULT VALUE FILT Filter settings of 1 6 are available e 1 is the fastest filter 3 is the slowest Automatic Re zero range ZERO 2 Settings of 1 to 6 are available Stability symbol range STA Settings of 1 to 6 are available 6 1 is the smallest stability range and 6 is the largest Weight Tracking Range ITR Settings of 1 to 6 are available 14 Adam Eq
16. med to provide a customised print out to give you the readings you require Doctor patient DiSP1 DiSP2 DiSP3 details can all be enabled or disabled to suit the information you need to see 1 Switch on the scale then press the kg Ib key during the self checking test of the display 2 The display will show the first function FEL 3 Press the kg Ib key to select F PTSEL and then Zero to enter and show the current settings SETTING DESCRIPTION SELECTIONS dr id Doctors Id number ON OFF PALId Patient Id number ON OFF DiSP 1 Display 1 shows the weight of the patient ON OFF DiSP2 Display 2 shows the height of the patient ON OFF DISP3 Display 3 shows the BMI of the patient ON OFF CAL Print out following calibration ON OFF d t Date and time ON OFF 4 Press the Print key to change the setting for the printing detail control and press Zero to save 5 Press the kg Ib key to exit and continue 12 Adam Equipment Company 2012 6 5 ULTRASONIC HEIGHT CALIBRATION OLTRA The Ultrasonic height sensor has been factory calibrated and should not require frequent calibration If there is a problem with height measuring proceed as below 1 Switch on the scale then press the kg Ib key during the self checking test of the display 2 The display will show the first function FEL 3 Press the kg Ib key to select FS and then Zero to enter the sensor calibration section A
17. mes with 4 x wall fixing brackets that can be secured to the pillar before fixing to the wall If the wall fixing brackets are being used attach these when you fix the M4 x 10 screws to the pillar fixing inserts Fasten securely to the wall once you have selected the position the MUW will be used in 3 0 LOCATING AND PROTECTING YOUR SCALE 36 Avoid extremes of temperature Do not place direct sunlight or near air conditioning vents Avoid unstable power sources Do not use near large users of electricity such as welding equipment or large motors Do not let the balance battery go flat If you are not using it for a long time you should charge the battery periodically to make sure the battery does not lose its charge 2 E m Keep free from vibration Do not place near heavy or vibrating machinery Avoid high humidity that might cause condensation Keep away from direct contact with water Do not spray or immerse the balance in water Do not place near open windows air conditioning vents or fans that may cause a draft and unstable readings J amp PX Keep the scale clean Do not stack material on the top pan when it is not in use 4 Adam Equipment Company 2012 4 0 KEYPAD DISPLAY FUNCTION The keypad and display have a number of features as shown and explained below Stable Indicator Zero Indicator The Battery Symbol Charging LED Hold
18. n cm feet and inches and inches There is an internal rechargeable battery as well as wheels fitted to the base that make the MUW totally portable The results can be sent to a printer or PC via the RS232 communication port either manually or automatically 2 0 SETUP 2 1 UNPACKING AND SETTING UP YOUR MUW The MUW has been packed in such a way to make it quick and easy for the USER to assemble please follow the instructions as below 1 Remove the base and pillar sections from the packaging 2 Lift the lower pillar section and place it with the screw holes at the rear onto the back of the base allowing for the cable to hang freely in the open area 3 Fit and tighten the 4 x M5 x 15 bolts and washers through the fixing plate of the lower pillar section and into the base then slide the pillar cover down so that it locates securely Fix the pillar cover at the rear using 2 x M4 x 10 screws 4 Lift the central pillar section into position and slide it with the screw holes at the rear onto the fixing insert ensuring the cable hangs freely inside the pillar 5 Fit and tighten 4 x M4 x 10 screws through the pillar and into the insert 6 Lift the top pillar section into position and slide it onto the fixing insert with the sensor housing facing the front again ensuring the cable hangs freely inside the pillar 7 Fit and tighten 4 x M4 x 10 screws through the pillar and into the insert 3 Adam Equipment Company 2012 The MUW co
19. nr ut eH epit ores 11 63 SETTING THE PRINTING CONTROLS SER 11 6 4 PRINTING DETAIL CONTROL 12 65 ULTRASONIC HEIGHT CALIBRATION 13 66 SETTING THE HOLD FUNCTION 6 13 6 7 SETTING DATE AND TIME FI co Dre ttti nod agus 14 6 8 SET WP SED ooo do bI cr EB ea Pe al once Ctt 14 6 9 TECHNICAL PARAMETERS 15 7 0 OUSERGCAUBRHANMION tuti uta uo teeth baht ac RR Ba EE 15 8 0 SERIAL INTERFACE SPECIFICATIONS exti ipa OR Uk RAE 16 9 0 TROUBEE SHOOTING ennn His ABE Deb 16 9i ERROR MESSAGES 17 10 0 TECHNICAL SPECIFICATIONS 17 11 0 WARRANTY INFORMATION cis ttn aub p tup n ERU 18 2 Adam Equipment Company 2012 1 0 INTRODUCTION The MUW Health and Fitness scale provides the weight and height of a patient before calculating the BMI based on the results Each result will be displayed on the Indicator and held until the result is cleared the BMI result can be used to help evaluate some ones overall health Units of weighing are Kg Lbs and Lbs and Ounces Height measurements are displayed i
20. uipment Company 2012 1 Switch on the scale then press the kg Ib key during the self checking test of the display 2 The display will show the first function FIEL 3 Press the kg Ib key to select F8 SET then Zero to enter and show the first parameter 4 Press the Print key to change the setting and Zero to save and move to the next parameter press cm ft to exit To return to normal operation turn the scale OFF and then ON again 6 9 TECHNICAL PARAMETERS F9 TECH This is a menu available only to qualified service personnel for factory adjustments 7 0 USERCALIBRATION 1 Switch on the scale and whilst the display counts down press the Clear key 2 The display will show kg or Ib press Print to select the unit of weight being used for the calibration and then Zero to confirm 3 The display will show CAL XX XX being the last calibration weight to be used 4 Press the Print key to change the value if required and Zero to confirm 5 The display will show the Zero A D which should be stable 6 Press the Zero key to confirm the Zero point and the display will show LOd XX XX being the calibration weight value to be loaded onto the top pan 7 Load the top pan with the calibration weight and press the Zero key 8 The display will show PASS for a successful calibration and return to normal weighing displaying the calibration weight value correctly 9 Remove the weight from the pan