Home
eGSM11-100c
Contents
1. PLC Power Supply Specifications Item Specifications Power supply 50mA 24VDC Antenna Specifications Item Specifications 850 1900 MHz Applicable area North America Central America and South America Frequency of antenna 900 1800 MHz Applicable area Other areas except America 1 LLL LED status LLL lt The system will take about total 30 40 seconds to setup EXGSM11 after power connected gt When power is connected GR signal will flash once and RD signal will start flashing quickly flashing once about per second After about 15 seconds RD signal will flash slowly flashing once per 3 seconds it means EXGSM11 is ready After another 15 seconds GR signal will start to flash it means the system is totally setup for working Note When RD signal flashes guickly it means EXGSM11 is searching the GSM network When RD signal flashes slowly it means the network is found and GSM module is on ready status Description of Function 1 EXGSM11 can store 3 sets of telephone number 2 EXGSM11 has been triggered to send SMS EXGSM11 start to send SMS to the first phone number and then dialing out to the first phone number When the call comes in the receiver will hear short beeps and receive the SMS with alarm message If the phone call was answered and pressed gt or key then EXGSM11 will stop sending SMS and stop dialing out next phone number If phone call do not be answered or is answered
2. LIYAN PROGRAMMABLE LOGIC CONT ROLLER LYPLC EXGSMII USER S MANUAL This manual contains text diagrams and explanations which will guide the reader in the correct installation and operation of the GSM module It should be read and understood before attempting to install or use the unit Before install SIM card to EXGSM11 please use cell phone to remove password of SIM card if there is OLL Introduction EEE The EXGSM11 module Hereafter referred to as the EXGSM11 can send an SMS and dial out to notify user if any problem of equipments happened or user can dial in by mobile phone to control start equipments EXGSM11 is a quad band frequency 850 900 1800 1900MHZ EEE Dimensions EEE Unit mm Attachment antenna D 90 co TOOOOO Vv 39 6 lt lt 48 0 Input Output VCC 24VDC OUT1 OUT2 INO IN1 IN2 IN3 K bs x A OLL Specifications OLL General Specifications Item Specifications Ambient temperature range 0 to 55 C during operation storage temperature 20 70 C Ambient humidity 35 to 85 RH during operation Dew condensation shall not be allowed Operating atmosphere Corrosive gas and many dusts shall not be detected Number of occupied I O points Don t occupy any I O points Applicable PLC Ex1s Ex1n Ex2n series
3. age in English send SMS Wait EXGSM11 sends confirmation SMS Later on if you need to change the message then you ll have to override the previous message as follows SO1 new message in English send SMS Wait EXGSM11 sends confirmation SMS S02 new message in English send SMS Wait EXGSM11 sends confirmation SMS S15 new message in English send SMS Wait EXGSM11 sends confirmation SMS If no need to change the message from a specific zone then skip dialing that zone The English message must be short than 16 letters including space Note EXGSM11 will send back a SMS only to the first phone number with the content that you wrote for confirmation after EXGSM11 has received a programming SMS 5 Output1 output2 can be activated by any other telephone dial in EXGSM11 will answer the phone dial in and response with a long beep sound a To press password 1 if password is correct EXGSM11 will response with a long beep sound and output activates 1 second For example the password is 0000 then enter the key as 000041 b To press password 2 if password is correct EXGSM11 will response with a long beep sound and output2 activates 1 second For example the password is 1234 then enter the key as 1234 2 c To press password 3 if password is correct EXGSM11 will response with a long beep sound and output1 amp output2 activates 1 second Note EXGSM11 will chir
4. but do not press x or then EXGSM11 will keep sending SMS and dialing out next phone number till the third phone number is dialed out There are 30 seconds ringing time for each phone dial out of the first second and third phone number when triggered once 3 Initial SMS message 4 digits triggered from PLC terminals IN3 IN2 IN1 INO 0000 All functions are disabled 0001 ZONE 1 ALERT 0010 ZONE 2 ALERT 0011 ZONE 3 ALERT 1011 ZONE 11 ALERT 1100 ZONE 12 ALERT 1101 System reserved 1110 System reserved 1111 System reserved ERE Operation OLL 1 Install the phone number of EXGSM11 Obtain a SIM card with local phone number install it in your mobile phone and activate the SIM card using the initial pass number consisting of 4 digits Then remove the SIM card and install into EXGSM11 2 Change the manufacturer s passnumber initial passnumber 0000 a Dial the phone number of EXGSM11 using any telephone and start to execute the following steps after EXGSM11 answers usually after 3 ring tones b press EXGSM11 s 4 digits passnumber 00005 the system will signal you to start programming with one long beep sound if password is correct c Press x password long beep sound response For example you wish the new password is 1234 then you have to enter gt 01234 3 Install the phone numbers of the receivers that may obtain EXGSM11 messages IA a press EXGSM01 s 4 digits passnumbe
5. p 5 beep sounds if it is unable to recognize the keys which you enter or enter wrong password You can re enter the keys after 5 beeps stop There are another two chances for entering correct password LIYAN PROGRAMMABLE LOGIC CONTROLLER LIYAN ELECTRIC INDUSTRIAL LTD TEL 886 4 25613700 EXGSM11 edoc0706v100c FAX 886 4 25613408 Website http www liyanplc com E mail twliyan ms16 hinet net
6. r 0000 5 the system will signal you to start programming with one long beep sound if password is correct b To program first phone number Press 1phone number long beep sound response For example enter x 10938XXXXXX Please take note that this number will be the priority receiver of the messages c To program second phone number Press gt 2phone number gt long beep sound response For example enter 20937XXXXXX d To program third phone number Press gt 3phone number long beep sound response EXGSM11 will respond with a long beep sound for every step you program Within 30 seconds for each step completed you can program the next step To finish the programming you hang up the phone If EXGSM11 does not receive any program signal within 30 seconds it will hang up the phone by itself After you hang up the phone to finish the programming steps EXGSM11 will send an SMS to the first phone number including all phone numbers amp passnumber that you programmed for your reference 4 To program and change the SMS Alert messages EXGSM11 has 15 message zones installed by the manufacturer zone S01 through S15 Each message zone can carry an alarm message that you have to specify and install as follows Edit SMS message and send each SMS to that zone S01 message in English send SMS Wait EXGSM11 sends confirmation SMS S02 message in English send SMS Wait EXGSM11 sends confirmation SMS S15 mess