Home

User Manual - CCTV Cameras

image

Contents

1. SET enter 0 and press PAT OPEN it will save and finish the pattern N PAT OPEN High Speed Dome Enter the patter NO 1 4 and press the PAT OPEN to start pattern N TOUR FAR High Speed Dome Input the TOUR NO TOUR Far or directly press TOUR Far to start the Tour press 9 5 PRE High Speed Dome Input 95 call the camera menu PELCO MATRIX MODE SHI MON SET Matrix Press SHI MON 8 SET Call the matrix menu PREV WIDE Matrix Press PREV WIDE skip to the previous dome hold on 2sec on PREV WIDE to continuously skip the sixteen domes of connection matrix forwards NEXT TELE Matrix Press NEXT TELE skip to the previous dome hold on 2sec on NEXT TELE to continuously skip the sixteen domes of connection matrix backwards ENTER keyboard After program press Enter to confirm N SHI MON Matrix Input monitor ID press SHI Cam to select object monitor Remark Multi key PRE PRESET PAT PATTERN OPEN CLOSE NEAR FAR WIDE TELE SHI SHIFT ENT ENTER l7lPage Preset num 1 128 ProVisual JV 35 Handset PTZ Camera Tester Manual www pr Press PREV to back ress O Dac 6 Keyboard Menu Index Save preset Preset num ____ 1 128 Show preset Press PREV to back Clear preset Preset num 1 128 Press PR
2. E ES 10 AZoM TEE 10 4 2 2 Dome Scan E 11 4 23 Pattern RE i iip i saaa a e a e r its 12 ALAS TOQUE SUD EE 4 3 Protocol Setup 4 3 1 Pelco Matrix Model 4 3 2 Dome Control Model 4 4 System Setting Press the NO 4 Key Directly DS e Y KEEN NS EE 14 3 1 RS485 Bus Basic Character some dck red Ed de atten ses aise eS 14 5 2 Shortcut Keys Operation ooo ateo incita 16 6 Keyboard Mem Index 18 ProVisual JV 35 Handset PTZ Camera Tester Manual www provisualusa com 1 Summary The keyboard is a universal keyboard of security monitoring series which can control the ball type integrated camera of all kinds protocols matrix which has been equipped with Joystick which can control the revolving of the camera and the zoom magnification of lens with the LCD screen and the function of back light which can display the current operation order the control protocol name the current dome ID the current monitor ID and the state of joysticks The user can control the CCTV system more easily with the joystick and the LCD screen 1 1 Notice Please read the manual carefully and reserve it Please advert to the notice in manual Please don t place the keyboard in the moist place 1 2 Function and Characteristic e RS485 Bus Line and a keyboard can connect 31 domes at most in the direct control mode e Can be compatible with all kinds of protocols e Can control the Iris Focus and Zoom e Can
3. key eStarting Pattern N PATTERN input the design scan number 1 4 press PATTERN key to starting 3 6 4 Tour Multikey OFF Starting N TOUR TOUR press tour ID first then TOUR key starting the tour Direct press the TOUR key when the system only has one tour path 3 7 Call Dome Main Menu 9 5 PRESET Input 95 press PRESET key aim dome s menu will display on the monitor Pls reference to the Speed dome s user manual for setting the speed dome 3 8 Matrix Control 3 8 1 Call Matrix Main Menu SHIFT SET Call the main menu the menu will display on the object monitor How to use the keyboard Setting the matrix Pls refers the matrix operate manual 3 8 2 Confirm After Program ENTER after the matrix 1 programmed press ENTER reflects confirm after program As for the detail program please refer to the matrix operation manual 3 8 3 Change The Monitor ID N SHI MONT input the monitor s ID and then press SHI MON the image and the dome camera s menu will display on the monitor 4 Keyboard Menu Control e Keyboard parameter set up Turn on the power and press the MENU the system information will display on the screen like the picture 4 1 1 press again the system information will disappear You can do all the keyboard operation while in the standby condition or the system information display condition Press MENU and hold on 2 sec you will enter
4. set and call the preset run the scanning the pattern and the tour e Can control the matrix and through which can control the dome indirectly e Equipped with the 3D Joystick and a LCD screen e The LCD can display the current operation order the control protocol name the current dome ID the current monitor ID and the state of joysticks e Infrared ray emission emission the same data amp content as RS485 1 3 Technical Data gt Electrical character Input 9V 12V DC Power 2 5W Standby Lithium 3 6 4 2 V 3500mAh gt Communicate character Communicate interface RS485 x 1 infrared emission Communicate frequency 2400 4800 9600 19200bps Communicate distance RS485 can reach 1 2Km infrared emission reaches 10m gt Operational environment Operating temperature 0 C 50 C Relative humidity less than 90 gt Dimension Lx W x H 168mm x 86mm x 28 3mm Weight 0 57kg 3lPage ProVisual JV 35 Handset PTZ Camera Tester Manual www provisualusa com 2 Keyboard Connection There is interface on the back of the keyboard which equipped with kinds of communication interface RS485 and infrared emission which can connect with and control kinds of peripheral equipments 2 1 RS485 Interfaces RS485 interfaces are on the 2bit ribbon cable connection of the keyboard RS485 A B can connect with the dome when the keyboard controls the dome directly RS485 A B can connect with DVR or other keyboards when the keyboard cont
5. the main menu as the picture 4 1 1 1 show The entire menu setting need enter the main menu first and use the correspond NO or the Joy calibrate to move UP and DOWN While you find the item you need move the joystick RIGHT or LEFT to enter the menu 1 Keyboard setup 2 Dome setup 3 Protocol select 4 System setup Figure 4 1 1 5 Exit menu e Save the setting After setting the function you need press ENTER to save the setting After finishing the setting the TFT will display Success e Back to Previous menu Press the PREV key to back to the previous menu SlPage ProVisual JV 35 Handset PTZ Camera Tester Manual www provisualusa com 4 1 Keyboard Parameter Setting 4 1 1 Keyboard ID Setup 1 Enter the main menu Screen will display picture4 1 1 1 1 Keyboard setup 2 Dome setup 3 Protocol select 4 System setup Figure 4 1 1 1 5 Exit menu 2 Press 1 to select the keyboard setting as TFT as Picture4 1 1 2 Set KB ID 1 64 Set Baudrate 2400bps J oy calibrate Figure 4 1 1 2 About keyboard 3 Press 1 again will show the picture Picture4 1 1 3 1 Set KB ID 1 64 Figure 4 1 1 3 4 Press 1 to select the ID Setting Picture4 1 1 4 1 Set KB ID 1 64 Figure 4 1 1 4 Use the Number key to select the camera ID in the range 1 64 and then press the Enter to save the screen will display Success as picture 4 1 1 5 Success Figure 4 1
6. 1 5 If the NO you input is beyond the range1 64 it will display Error as picture 4 1 1 6 Error Figure 4 1 1 6 5 Press PREV or use the shake toward to LEFT to back to previous menu 9IPage ProVisual JV 35 Handset PTZ Camera Tester Manual www provisualusa com 4 1 2 Keyboard Baud Rate Setting Enter the main menu as the TFT picture 4 1 1 1 show Press 1 will show on the TFT as picture 4 1 1 2 Press 2 select the Baud Rate setting as Picture 4 1 2 1 2 Set Baudrate 2400bps 4800bps 9600bps 19200bps Figure 4 1 2 1 2400bps 4800bps 9600bps 19200bps is available commonly under the IR emission mode baud rate is 2400bps or 4800bps You can select the Baud rate you need and press the ENTER to save If you operate success the screen will show Success Press PREV or move the joystick to LEFT to back to previous menu Caution If connect to the matrix baud rate must be 9600bps Several keyboards work together it must use 9600bps or 19200bps 4 1 4 Keyboard Information Display Enter the keyboard information display menu as LCD Picture 4 1 1 2 Press 2 to check the keyboard information as LCD Picture 4 1 4 1 Version 1 00 KB ID 001 Protocol Pelco d Figure 4 1 4 1 Baudrate 2400bps 4 2 Dome Setup 4 2 1 Preset Setup Enter the main menu as picture 4 1 1 1 and press 2 to enter the dome setting menu as picture 4 2 1 1 This part you can set the follow function Pr
7. 2 Dome 3 Dome 4 aa d3 ood Co E co mam em um om s E E A JJ JI O Dome 5 Dome 6 Dome 7 Dome 8 Ve 5 Page ProVisual JV 35 Handset PTZ Camera Tester Manual www provisualusa com 3 Operation Figure 2 4 2 RS 485 Resistance Switch Navigation Figure 3 1 1 Attention please because different system have some different special operation ways so should consider the actual requirement when operation in some special systems 3 1 Electrify When the power is on the keyboard will automatically check the baud rate protocol of the keyboard aim dome and the aim monitor and all the info Will be displayed on LCD screen 3 2 TFT Display Screen TFT screen display contents aim dome aim monitor and baud rate etc And at the end of the content will show the current operation order and the states of joystick as follows figure show When operation TFT back light will on and will be off 10s after the operation Keyboard Keyboard ID Camera ID Monitor ID Figure 3 1 2 Protocol Baudrate Multikey 123 SET 6lPage ProVisual JV 35 Handset PTZ Camera Tester Manual www provisualusa com 3 3 Dome Control By Navigation Key Functions of Navigation key Dome rotation control and Object dome menu setup e W
8. 8 Figure 4 2 1 6 Press PREV to back Input the PRESET NO which you want to clear and press the Enter to clear it and it will show Success and back to previous menu 4 2 2 Dome Scan Setup Enter the menu 4 1 1 1 Press 2 enter the dome setting menu as the picture 4 2 1 1 Press 2 again to enter the dome scan setting as picture 4 2 2 1 1 Set left limit 2 Set right limit Figure 4 2 2 1 3 Run scan lllPage ProVisual JV 35 Handset PTZ Camera Tester Manual www provisualusa com Dome scan setting include the Left limit Right Limit and Run scan Press 1 to set the Left limit as picture 4 2 2 2 show Press ENTER sure Press PREV to back Figure 4222 While enter the dome limit setting menu move the dome to the suitable position and press Enter Jto save and will show Success and back to previous menu Select the item 2 to set the Right limit and do the same as the left limit setting Back to the menu and press 3 to operate the Run Scan Caution Under commonly mode navigate key and other keys operation is invalid While enter the dome s LEFT or RIGHT limit setting menu the keyboard navigate key will directly control the dome and the lens control zone also can control the dome s lens 4 2 3 Pattern Setup Enter the menu as the picture 4 1 1 1 Press 2 enter the dome setting menu as the picture 4 2 1 1 And then press 3 enter the pattern setting as picture 4 2 3 1 sh
9. EV to back Set KB ID 1 64 Set Baudrate 2400bps Set left limit Press ENTER sure 2 Set right limit 1 Keyboard setup R Press PREV to back KUN scan Joy calibrate About keyboard Press ENTER sure pattern num __ Press PREV to back Set pattern Set dome preset Run pattern Press 1 to start 2 Dome setup Set dome scan Press 0 to start Set dome pattern Press PREV to Set dome tour Tour num Insert preset 1 Preset num 2 Speed 1 Matrix 3 Well 2 Dome Run tour 3 Protocol setup 1 Pelco Matrix 2 DH DVR 1 System mode PAL NTSC 2 IR Function ON OFF 1 Factory 3 Screen time s 000 255 2 Pelco p 4 key Backlight s 000 255 3 Pelco d 5 LCD Backlight 000 255 6 Brightness 000 255 7 Contrast 000 255 8 Saturation 000 255 9 Language CHN ENG 10 Init System ON OFF Press PREV to back 4 System setup Keyboard V1 00 Keyboard ID 001 Camera ID 001 Monitor ID 001 5 Exit menu Protocol pelco d Baudrate 2400bps Multikey ON OFF 123 set l8lPage
10. PROVISUAL O JV 35 ProVisual Handset PTZ Camera Tester Manual User Manual www provisualusa com ProVisual JV 35 Handset PTZ Camera Tester Manual www provisualusa com Contents AD SUMMARY EE 3 NN E dE 1 2 Function and Characteristic 1 3 Technical Data oooooononnonncninncnnoccconncnonncinnccnnncnnno 2 Keyboard Connection 2 2 Direct Connect With Dome 2 3 Keyboard Connection In The System 4 2 1 RS485 Interfaces segs ses sees dees ys ets sees dete sivas repita 4 3 Operation 0 24 sai he ain d a eee A Ri E SR eA RA ds 6 3 3 Dome Control By Navigation Key 0 ccc eeccescecesceseseecsaeesssececeseacecsaeecsaeeesaeceseseeessaeessaeeseeeesaeees 7 3 4 Rigger The Aim Dome Multikey OFF 7 A o NN 6 3 2 TFT Display Sere acom ana hs 6 3 5 Lens Control Multikey ON H 3 6 Dome Function Operation dd 7 3 6 1 EE 7 3 6 2 Scan Multikey OFE EE T 3 6 3 Pattern Multikey OF Flood ios 7 3 6 4 Tour Mu OF adds 8 3 7 Call Dome Main Mem siii feast asd cep cscs dens didas 8 3 8 Matrix Control ion adi 8 3 8 1 Call Matrix Main Mei ao 8 3 8 2 Confirm After Program EE 8 3 5 3 Change The Monitor TD A ii 8 4 Keyboard Menu Control A 8 4 1 Keyboard Parameter Setting cocida 9 4 1 1 Keyboard ID Setup 9 4 1 2 Keyboard Baud Rate Setting A 10 4 1 4 Keyboard Information Display corno corno no nnn nono nn ran nn ran nc cnn ncninno 10 ARM e a o i Ae Dea
11. S Keyboard Multikey ON OFF MENU Keyboard Display system information N CAM NEAR High Speed Dome Input Dome ID press CAM NEAR to select object dome NEXT TELE High Speed Dome Press NEXT TELE Zoom out PREV WIDE High Speed Dome Press PREV WIDE Zoom in TOUR FAR High Speed Dome Press TOUR FAR Far focus CAM NEAR High Speed Dome Press CAM NEAR Near Focus ALL THE SCAN CLOSE High Speed Dome Press SCAN CLOSE reduce Iris MODE PAT OPEN High Speed Dome Press PAT OPEN increase Iris SET N PRE High Speed Dome Adjust the image to object position Press SET to input the preset and press PRE to set the preset N PRE High Speed Dome Input preset ID press Preset to call the preset SET 1 SCAN High Speed Dome Adjust the image to object position CLOSE press Set to input 1 then press Scan to set scan Close left limit SET 2 SCAN High Speed Dome Adjust the image to object position CLOSE press Set to input 2 then press Scan l6lPage ProVisual JV 35 Handset PTZ Camera Tester Manual www provisualusa com to set scan Close left limit 1 SCAN CLOSE High Speed Dome Input 1 press Scan Closel to run scan SET1 N PAT OPEN High Speed Dome Press SET enter the pattern NO and press PAT OPEN Jit will start record the pattern information SET1 0 PAT OPEN High Speed Dome Press
12. connection But D should not exceed 7m Figure 4 1 2 e Problems in practical use In some circumstances user adopts a star configuration in practical connection The termination resistors must be connected to the two equipments that are father away from each other such as equipmentl and 15 refer to picture 4 1 3 As the star configuration is not in conformity with the requirements of RS485 standards problems such as signal reflections lower anti interference performance arise when the cables are long in the connection The reliability of control signals are decreased with the phenomena that the dome dose not responds to or just responds at intervals to the controller or dose continuous operation without stop In such circumstances the factory will recommends the usage of Rs485 distributor The distributor can change the star configuration connection to the mode of connection stipulated in the RS485standards The new connection achieves reliable data transmission refer to picture 4 1 4 1200 1 6 Main Control equipment 32 Figure4 1 3 l5SlPage ProVisual JV 35 Handset PTZ Camera Tester Manual Wwww proy isualusa com Here under this situation suggest use the RS485 Distributor RS485 4 1 4 14 2H 3 Figure 4 1 4 5 2 Shortcut Keys Operation SHORTCUT KEY ie ara FUNCTION OBJECT POWER 2S Keyboard Power ON OFF LOCK UNLOCK Keyboard Lock ON OFF SHIMON 2
13. eset Scan Pattern and Tour Set dome preset Set dome scan Set dome pattern Set dome tour Figure 4 2 1 1 Press 1 enter the dome Preset function setting as picture 4 2 1 2 1 Save preset 2 Show preset Figure 4 2 1 2 3 Clear preset Item 1 Save preset Item 2 Show the preset Item 3 delete the preset 10lPage ProVisual JV 35 Handset PTZ Camera Tester Manual www provisualusa com Press 1 enter the preset you can input the preset NO as picture 4 2 1 3 show Preset num 1 128 Figure 4 2 1 3 Press PREV to back After enter the preset menu you can use navigate key control the dome directly and input the preset NO to save as the picture 4 2 1 4 show And on the TFT screen will display Success Figure 4 2 1 4 Press Prev back to previous men Caution Under commonly mode navigate key and other keys operation is invalid While enter the dome preset menu the keyboard navigate key will directly control the dome and the lens control zone also can control the dome s lens Press 2 enter the Show the preset menu as picture 4 2 1 5 Preset num 1 128 Figure 4 2 1 5 Press PREV to back Input the Preset NO that want delete and press the ENTER to call it and the TFT will display Success Use the navigate Key or PREV back to previous menu Press 3 enter the clear the Preset to clear preset information as picture 4 2 1 6 show Preset num 1 12
14. hen operate the Navigation key at will to any direction Dome will rotate at the same direction and the direction will be displayed below right corner as SS MR dE When for menu ES the upper menu item gd for the next menu D for the sub menu or save the setup for un save or exit e Direct proportion between the speed of the Dome and the lean angle of the navigation keys lange lean angle faster rotation speed 3 4 Rigger The Aim Dome Multikey OFF N CAM N for Number input the serial number of the Dome Press CAM key to amend the add of the aim dome 3 5 Lens Control Multikey ON e Focus NEXT TELE PREV WIDE eZoom Multikey ON TOUR FAR CAM NEAR eLens ris Multikey ON PAT OPEN SCAN CLOSE 3 6 Dome Function Operation 3 6 1 Preset Pre set SET N PRESET Adjust pre set EN PRESET N for the number of the pre set 3 6 2 Scan Multikey OFF Left borderline SET 1 SCAN Right borderline SET 2 SCAN star 1 SCAN Enter the menu to set when need change the scan speed 3 6 3 Pattern Multikey OFF eSetup the Pattern SET IN PATTERN path SET 0 PATTERN Press SET key input the number of design scan 1 4 press PATTERN key enter the path setup state when TlPage ProVisual JV 35 Handset PTZ Camera Tester Manual www provisualusa com ending press SET key first then press 0 key then PATTERN
15. ime s 000 255 4 key Backlight s 000 255 5 LCD Backlight 000 100 6 Brightness 000 255 7 Contrast 000 2535 Figure 4 4 8 Saturation 000 255 9 Language CHN ENG 10 Init System ON OFF Press PREV to back 4 5 Exit Menu Press 5 Exit Menu 5 Appendix 5 1 RS485 Bus Basic Character eAccording to RS485 industrial standards RS485 Bus is of half duplex data transmission cables with characteristic impedance as 120 The maximum load capacity is 32 unit loads including main controller and controller equipment eDistance of RS485 bus transmission While use the 0 56mm 24AWG twisted cable as the communication the farthest distance it can reach as follow based on the different Baud rate Baud Rate Max Distance 2400bps 1800M 4800bps 1200M 9600bps 800M 19200bps 600M If user selects thinner cables or installs the dome in an environment with strong electromagnetic interference or connects lots of equipment to the RS485 Bus the maximum transmitting distance will be decreased To increase the maximum transmitting distance do the contrary l4IPage ProVisual JV 35 Handset PTZ Camera Tester Manual www provisualusa com e Connection and termination resistance The RS485 standards require a daisy chain connection between the equipment There must be termination resistance with 120 impedance at both ends of the connection refer to picture 4 1 1 Please refer to picture 4 1 2 for simple
16. ow 1 Pattern num 2 Set pattern Figure 4 2 3 1 3 Run pattern After enter the menu the system need input the pattern information you want you can put in the NO1 4 and Press the ENTER The mouse will skip to the next item automatically to set the second patter you need If you already have it you can skip it and select the 3 to run the pattern directly Pattern setting After enter the pattern setting menu move the dome do the suitable position and press the 1 to start record the scan track The screen will display Start like the picture4 2 3 2 Press 0 to finish the scan record and the screen will show Success and back to the previous menu Press 1 to start Press O to start Press PREV to back Figure 4 2 3 2 Caution Under commonly mode navigate key and other keys operation is invalid While enter the dome s PATTERN setting menu the keyboard navigate key will directly control the dome and the lens control zone also can control the dome s lens 4 2 4 Tour Setup Press 2 enter the dome setting menu as the picture 4 2 1 1 show And then press 4 enter the tour setting as the picture 4 2 4 1 show 12lPage ProVisual JV 35 Handset PTZ Camera Tester Manual www provisualusa com 1 Tour num __ 2 Insert preset 3 Run tour Figure 4 2 4 1 After enter the menu you need input the TOUR information the range you can put is 1 6 and press the ENTER Iconfirm Then
17. rols the dome by matrix RS485 Infrared Emission Video Out Input DC12V Interface 2 2 Direct Connect With Dome Keyboard connects the Dome wit RS485 The RS485 interface of the Dome is on the commutator of the Dome Press the metal button in the hanging frame open the commutator will find a 4bit power jack follow the surface instruction to find RS485 A B follow the instruction Connection maybe different when come from different manufacturer 12V A B RS485 E A B Dome Figure 2 3 1 2 3 Keyboard Connection In The System Indirect control the dome when connect with matrix as figure 2 4 1 contrariwise will control the domes directly parallel connect the keyboard and dome to the bus of RS 485 all the keyboard can control any dome among them under this way the add of the main keyboard should be 1 and baud rate should be 9600bps as figure 2 4 1 4lPage ProVisual JV 35 Handset PTZ Camera Tester Manual www provisualusa com Figure 2 4 1 Matrix Caution 1 The max quantity of master equip and be charged equip controlled by a RS485 bus is so when use the keyboard to control direct the max dome quantity is 31 2 Max quantity keyboard in a system is 4 also the 4 keyboards should be different ID o o e A ED e SS DS HHH co ca co Co E OD aro E CO Oc Occ ue ESE Le less les Kgyboard 1 Keyboard 2 MM JI II e A ED Dome 1 Dome
18. the mouse will auto skip to the second TOUR setting If first one is ok Users can skip it And it will show the Success and back to the previous menu Select the Item 2 as picture 4 2 4 2 you need input the tour preset and in the second item you need put in the speed information the range is 1 127 In the third item you need input the time how long it need to stop the range is 1 255 After finishing all the step press the ENTER and will display Success and back to previous menu 1 Preset num 2 Speed 3 DWell Figure 4 2 4 2 Press 3 Run the TOUR Caution This model does not have the insert tour preset function 4 3 Protocol Setup Enter the menu as picture 4 1 1 1 Press 3 enter the Protocol setting as picture 4 3 1 1 Matrix 2 Dome Figure4 4 3 1 Pelco Matrix Model Press 1 enter the PELCO Matrix model as the picture 4 3 1 1 And then press the ENTER to select the Protocol and back to previous menu 1 Pelco Matrix 2 DHDVR Figure 4 3 1 1 4 3 2 Dome Control Model Press 2 enter the dome control model as the picture 4 3 2 1 According to the user s need select the suitable PROTOCOL and back to the previous menu 1 Factory 2 Pelco p 3 Pelco d Figure 4 3 2 1 l3lPage ProVisual JV 35 Handset PTZ Camera Tester Manual www provisualusa com 4 4 System Setting Press the NO 4 Key Directly 1 System mode PAL NTSC 2 IR Function ON OFF 3 Screen t

Download Pdf Manuals

image

Related Search

Related Contents

Biostar P4TGV Owner's Manual  BDT-101CI Installer Manual v1.0  NucleoFast® 96 PCR - MACHEREY  CACES R 372 m catégorie 2. Pelles hydrauliques  Techmo Hidrófugo 2 Techmo Hidrófugo 2  Remote Backup Software User Manual V 2.0  Carneiro Hidráulico de PVC – Comercial Construção  Installation Manual - Pipistrel Aircraft  