LDW-6095K Operating Manual

image

Contents

1. 66 5 14 Current Range 66 5 15 EOWBAT SCFBeIL 67 5 16 Appendix M 68 6 MAINTENANCE ones xa xe nick Re Rc i Rai ees 69 0 1 Cleanilig siu 69 6 2 Replacement of batteries 69 7 5232 PC SERIAL 70 8 Download the saving data from the SD card to the computer EXCEL software 72 9 PATENT des 76 10 THE ADDRESS OF AFTER SERVICE CENTER 77 1 FEATURES Analysis for 3 phase multi power system 1P 2W 1P 3W 3P 3W 3P 4W 3 current probes LCP 1201 are included if change the current probes the calibration procedures are not necessary Current probe input signal ranges with selection Input signal ACV 200 mV 300 mV 500 mV 1 V 2 V 3 V Ranges ACA 20 A 200 A 2000 A 30 A 300 A 3000 A Meter can cooperate the universal current probes Complete set with 4 PCs Test Leads 4 PCs Alligator clips 3 PCs Clamp Probe LCP 1201 AC to DC 9V adapter 2 G SD memory card and Carrying bag Measurement V phase to phase V phase to ground A phase to ground KW KVA KVAR PF phase KW KVA KVAR PF system KWH KVAH KVARH PFH system Phase angle Harmonics display 1 5
2. cyber IS gt INDUSTRIELLE TECHNOLOGIE 3 Phase Power Analyser Data Logger Model LDW 6095K Your purchase of this 3 PHASE POWER ANALYZER marks a step et forward for you into the field of precision measurement Although this POWER ANALYZER is a complex and delicate instrument its durable structure Power 4 Harmonic Analyzer sphas will allow many years of use if proper operating techniques are 4 GR amp developed Please read the following instructions carefully and always keep this manual within easy HH reach N vi V2 A V1 V2 INPUT 600V CATIII 600V OPERATION MANUAL Caution Symbol Caution Risk of electric shock During the measurement do not open the cabinet Caution Do not apply the overload voltage current to the input terminal Remove test leads before open the battery cover Cleaning Only use the dry cloth to clean the plastic case Environment Conditions Installation Categories 600V Pollution Degree 2 Altitude up to 2000 meters Indoor use Relative humidity 80 max TABLE OF CONTENTS 1 FEATURES ua dite HORAE 1 2 SPECIFICATIONS aeea aea 2 2 1 General 2 2 2 Electrical Specificat
3. nem 121 EE Uem AB AC AD mu qp em AG AH Al 1 Unit P SUM Unit 51 Unit 52 Unit 3 Unit S SUM Unit 2 OKVA OKVA OKVA en 0 0 4 0 KW OKVA OKVA OKVA OKVA 0 KW 0 OKVA OKVA OKVA 6 0 KW OKVA OKVA OKVA 7 8 OKVA OKVA OKVA 9 10 0 KW 0 KW 11 12 _13 EXCEL data screen 4 for example D amp HSGS T B A A MD 5 see 2 pr Rae AX21 AL AM AN AP AQ AR FEM AW Unit Q2 Unit Q3 Unit Q SUM Unit 1 Unit 2 Unit 2 0 KVAR OKVAR OKVAR OKVAR 0 0 3 0 KVAR OKVAR OKVAR 0 KVAR 0 0 4 0 KVAR OKVAR OKVAR 0 KVAR 0 0 5 OKVAR OKVAR OKVAR 0 KVAR 0 0 6 0 KVAR OKVAR OKVAR 0 KVAR 0 0 E 0 KVAR 0 KVAR OKVAR 0 KVAR 0 0 8 0 KVAR OKVAR OKVAR 0 KVAR 0 0 9 OKVAR OKVAR OKVAR 0 KVAR 0 0 10 0 KVAR OKVAR OKVAR 0 KVAR 0 0 11 0 KVAR OKVAR OKVAR OKVAR 0 0 12 13 73 EXCEL data screen 5 for example Dees Sze Me 7 singe 12 TZU mo 121 AX AY AZ BB BC BD BF BG BH BI il PF3 Unit PF SUM Unit PFH Unit PHAS
4. 1 51 091 1 FREQ 10 Basic CP1201 200A 200mV Minute Second 37 25 19 screen 2 4 5 2 Folder WTAO1 ll 3P401001 XLS p Date 2008 11 28 00 03 17 Sampling Time 2 Trans Ref Delet File 0 SDVP 10 0 Decimal Basic 388 KB Type 1201 1946MB Range 200A 1946MB V Range 200mV RS232 Out Sel 1 1 Vi It 1 1 S1 Qi PFI ON FREQ Month Date Hour Minute Second 12 05 11 15 31 File Name description press A or in screen 2 to select expect file number from 001 to 050 Remark When press 4 or gt 2 sec the setting no Will change fast 1P201001 1P2 means one phase by two wires 1P301001 1P3 means one phase by three wires 3P301001 3P3 means three phases by three wires 3P401001 3P4 means three phases by four wires 1001 HAR means harmonic measurement PHA01001 PHA means phasor measurement 1001 TRA means transient measurement Remark Above file description 01 means folder number 001 means file number D The up right display will show SHIFT1 symbol while pressing SHIFT KEY once in screen 2 and then press to enter next setting function as screen 3 File Name Sampling Time 20 The up right display will show SHIFT2 symbol while pressing SHIFT KEY again in screen 4 at this time press A or to select 1P 2W 1P2 1P 3W 1P3 gt 3P 3W 3P3 and 3P 4W 3P4 a
5. 0 000 KVA 0 000 KVAR 0 00 0 00 0 00 0 02 0 000 0 0 Hz B The bottom right display will show the recorded data points B 1 Each file can record up to 30 000 data points as screen 1 when the record points exceed 30 000 points system will create a new file automatically For example WTAO01001 XLS will be replaced by WTA01002 XLS B 2 While pressing REC KEY twice the data logger function will stop to execute the record points will disappear on bottom right display as screen 2 63 0 000 KW 0 000 KW 0 000 KW 0 000 KW 0 00 0 00 0 0 V 0 0 V 0 000 KW 0 000 KW 0 000 KW 0 000 KW 0 000 KVA 0 000 KVA 0 000 KVA 0 000 KVA 0 00 0 00 0 09 0 000 0 000 0 000 0 000 0 00 0 00 Freg screen DL S 11B 0 000 KVAH 0 0 Hz 0 000 KVAH 0 0 Hz 0 00 A 0 00 A 0 00 A 0 000 KVAR 0 000 KVAR 0 000 KVAR 0 000 KVAR 0 00 0 09 0 00 A 0 00 A 0 00 A 0 000 KVAR 0 000 KVAR 0 000 KVAR 0 000 KVAR 0 00 0 0 5 12 Data HOLD Function A During the measurement press HOLD KEY once the bottom right display will show HOLD symbol as screen 1 B Press the HOLD KEY twice will disable the Data HOLD function and the HOLD symbol will disappear in the meantime 0 000 KW 0 000 KW 0 000 KW 0 000 KW 0 00 0 00 23009 0 000 KWH 0 000 KVARH 0 000 KW 0 000 KW 0 000 KW 0 000 KW 0 0 V 0 0 V 0 0 V 0 000
6. 1 FREQ 1 1 1 1 Month Date Hour Minute Second 13 14 37 25 4 5 5 SD Format Formatting function for SD CARD A The indicator Y or N will appear on right side display of the option while pressing SHIFT KEY continuously at least two seconds and press A the display will show Y in highlight as screen 2 press SETUP KEY again to confirm to format SD CARD then return to screen 1 or else press SETUP KEY in OR option return to screen 1 Press W in screen 1 to enter next setting function SD Format PT 24 screen 1 4 5 5 Folder Name WTAO1 File Name 3P401001 XLS REC Date 2008 11 28 00 03 17 Sampling Time 2 Trans Ref 220 0 V 0 SDVP 10 0 Decimal Basic 388 KB Type 1201 Free Size 1946MB Range 200A Total Size 1946 MB V Range 200mV RS232 Out Sel Vi P1 51 01 PF1 ON FREQ Month Date Hour Minute Second 13 14 37 25 screen 2 4 5 5 Folder Name WTAO1 File Name 3P401001 XLS REC Date 2008 11 28 00 03 17 Sampling Time 2 Trans Ref 220 0 V Delete File 0 SDVP 10 Y ORN Decimal Basic 388 KB Clamp Type 1201 Free Size 1946MB Range 200A Total Size 1946MB V Range 200mV RS232 Out Sel Vi P1 51 01 PF1 ON p FREQ 1 1 1 1 Month Date Hour Minute Second 13 14 37 25 25 4 5 6 PT Set the Potential Transformer When press SHIFT KEY once the symbol SHIFT1 will disappear as screen 2 at this tim
7. Phase Diagram Key 3 30 Fig 1 will display the phasor diagram as the Screen 1 2 Description of phasor diagram 1 V2 Phase voltages in phasor format with respect to V1 A1 A2 A3 Line currents in phasor format with respect to A1 b AVE Average of the line voltages V12 V23 and V31 an the line current A1 A2 and A3 Calculated voltage and current of neutral with respect to ground d dV Historical maximum value of V1 V2 V3 Min V1 V2 Min V1 V2 V3 100 VUR Voltage unbalance ratio 56 do2 do d2 do The first number is Zero Sequence Unbalance Ratio in 9o dO of voltage or current 42 The second number is the Negative Sequence Unbalance Ratio in 9o d2 of voltage or current 9 04 Historical maximum value of 1 A2 Min A1 A2 Min A1 A2 A3 100 h AUR Current unbalance ratio Screen 1 5 8 VI 220 2 NN j eA ODW T Woo GON OO gt 3 1 v3 Ae AYN 26 26 26 2920 gt gt hes aq 9027 60 0 Hz a Zt Se 57 Screen 2 5 8 ug 221 3 219 8 221 5 41 14 85 70 59 9 umm _ 5 9 Voltage Current Waveform 1 Press Waveform Key 3 31 Fi
8. 388 KB 1201 1946MB Range 200A 1946 V Range 200mV RS232 Out Sel Vi P1 Si 01 PF1 FREQ 1 1 1 1 Date Hour Minute Second 05 11 14 49 3P401001 XLS 2008 11 28 00 03 17 2 Trans Ref 220 0 V 0 SDVP 10 0 Decimal Basic 388 KB 1201 1946MB Range 200A 1946MB V Range 200mV RS232 Out Sel Vi P1 Si 01 PF1 FREQ 1 1 1 1 Month Date Hour Minute Second 05 11 14 34 18 gt Folder Name range WTAO1 to WTA10 Press A or to select the expect folder number the number consists of 01 to 10 as screen 1 Press A or W continuously at least two seconds can skip the numbers faster D Press SHIFT KEY once the symbol SHIFT1 will appear on up right display and then press W to entry next setting function as screen 2 Folder Name File Name 4 5 2 File Name Set the file name for SD A The screen will show NO File indicator in REC Date option when the selected file is new as screen 1 B The screen will show recording date and time in REC Date option when the selected file has been recorded as screen 2 screen 1 4 5 2 Folder Name File Name REC Date Sampling Time Delet File Month 3P401001 XLS NO File 2 0 0 388 KB 1946 MB 1946 MB 1 1 1 1 Date Hour 13 14 Trans Ref SDVP Decimal Clamp Type A Range V Range RS232 Out Sel Vi
9. Vi P1 51 01 PF1 p FREQ 1 1 1 1 Date Hour Minute Second 13 14 37 25 29 screen 2 4 5 8 Folder Name WTAO1 File Name 3P401001 XLS REC Date 2008 11 28 00 03 17 Sampling Time 2 Trans Ref 220 0 V Delete File 0 SDVP 10 0 Decimal Basic 388 KB CP1201 1946MB Range 200A 1946MB V Range 200mV RS232 Out Sel Vi P1 51 01 PF1 p FREQ 1 1 1 1 Date Hour Minute Second 13 14 37 25 4 5 9 Trans Ref Nominal voltage for transient detection reference A When press SHIFT KEY once will disappear as screen 2 at this time press A or W to adjsut the voltage level to 50 0 V to 850 0 V Press SHIFT KEY once again will return to screen 1 then press W to enter next setting function Trans Ref SDVP 30 screen 1 4 5 9 Folder Name WTAO1 File Name 3P401001 XLS REC Date NO File Sampling Time 2 220 0 V 0 90 SDVP 10 0 Decimal Basic 23 Clamp Type CP1201 Free Size 1904MB Range 200A Total Size 1927MB V Range 200mV RS232 Out Sel Vi P1 S1 01 PF1 ON FREQ Month Date Hour Minute Second 14 09 22 41 screen 2 4 5 9 Folder Name WTAO1 File Name 3P401001 XLS REC Date NO File Sampling Time 2 220 0 V Delete File 0 SDVP 10 0 Decimal Basic 23 Clamp Type CP1201 Free Size 1904MB Range 200A Total Size 1927MB V Range 200mV RS232 Out Sel 1 1 Vi 124 Si Ql PF1 ON FRE
10. 999 9 KW 0 1 KW 1 0 8KW 1 000 to 9 999 MW 0 001 MW 1 0 008MW The resolution is changed according the different ACA range Apparent Power Resolution Accuracy 0 000 to 9 999 KVA 0 001 0 01 0 1KVA 1 0 008KVA 10 00 to 99 99 KVA 0 01 0 1 KVA 1 0 08 100 0 to 999 9 KVA 0 1 KVA 1 0 8 1 000 to 9 999 0 001 MVA 1 0 008 The resolution is changed according the different ACA range Reactive Power Range Resolution Accuracy 0 000 to 9 999 KVAR 0 001 0 01 0 1KVAR 1 0 008 KVAR 10 00 to 99 99 KVAR 0 01 0 1 KVAR 1 0 08 KVAR 100 0 to 999 9 KVAR 0 1 KVAR 1 0 8 KVAR 1 000 to 9 999 MVAR 0 001 1 0 008 MVAR The resolution is changed according the different ACA range Watt Hour Active Power Hour WH Resolution Accuracy 0 000 to 9 999 KWH 0 001 KWH 2 0 008 KWH 10 00 to 99 99 KWH 0 01 KWH 2 0 08 KWH 100 0 to 999 9 KWH 0 1 KWH 2 0 8 KWH 1 000 to 9 999 MWH 0 001 MWH 2 0 008 MWH VA Hour Apparent Power Hour SH Resolution Accuracy 0 000 to 9 999 KVAH 0 001 KVAH 2 0 008 KVAH 10 00 to 99 99 0 01 2 0 08 KVAH 100 0 to 999 9 KVAH 0 1 KVAH 296 0 8 KVAH 1 000 to 9 999 MVAH 0 001 MVAH 2 0 008 MVAH VAR Hour Re
11. It is used for specific single phase systems refer page 36 which has two transformers Transformer 1 110 V 220 V Transformer 2 110 V Germany 20 2008 016 337 4 JAPAN 3151214 TAIWAN M 358970 M 359043 CHINA ZL 2008 2 0189918 5 ZL 2008 2 0189917 0 USA Patent pending 10 THE ADDRESS OF AFTER SERVICE CENTER Distributed and supported in Australia by WWW esis com au Ph 02 9481 7420 02 9481 7267 ESIS 42 esis co m au Industrial Electronics 77 1106 LDW6095 1012 LDW6095
12. KVA 0 000 KVA 0 000 KVA 0 000 KVA 0 00 0 00 0 09 0 0 V 0 0 V 0 0 V 0 000 KVA 0 000 KVA 0 000 KVA 0 000 KVA 0 00 0 00 screen 1 5 12 0 000 KVAH 0 0 0 000 KVAH 0 0 Hz 0 00 A 0 00 A 0 00 A 0 000 KVAR 0 000 KVAR 0 000 KVAR 0 000 KVAR 0 00 0 00 A 0 00 A 0 000 KVAR 0 000 KVAR 0 000 KVAR 0 000 KVAR 0 00 0 0 5 13 BACKLIGHT KEY Control the backlight function of LCD to ON OFF 5 14 A Range Current Range KEY function The A Range Current Range function key is used to change the current range quickly b Press A RANGE KEY once will entry to screen as following screen 1 5 14 it is the same screen as screen 2 4 5 13 page 37 C The detail Current range Setting procedures please reafer to section 4 5 13 A range Setting Current range Setting page 37 Remark The function of the A Range Current Range key is available for the Clamp Type A Range V Range setting only screen 1 5 14 same as screen 2 4 5 13 3P401001 XLS 2008 11 28 00 03 17 2 Trans Ref 220 0 V 0 90 SDVP 0 0 96 Decimal Basic 388 KB Clamp Type CP1201 1946 MB 200A 1946MB V Range 200mV RS232 Out Sel Vi P1 S1 Ql 1 FREQ 111 111 Month Date Hour Minute Second 13 14 37 25 66 5 15 The LOWBAT screen as show on lower right display of the following screen 0 00 A 0 00 A 0 00 A 0 000 KW 0 000 KVA 0 000 KVAR 0 000 KW 0 000 KVA 0 000 KVA
13. Si 01 1 FREQ 1 1 1 1 Date Hour Minute Second 13 14 37 25 44 Folder Name WTAO1 File Name 3P401001 XLS REC Date 2008 11 28 00 03 17 2 Trans Ref 220 0 V screen 2 0 SDVP 10 4 5 16 0 Decimal Basic 388 KB Type 1201 1946MB Range 200A 1946MB V Range 200mV RS232 Out Sel Vi P1 61 01 PF1 FREQ 1 1 d Date Hour Minute Second 13 14 37 25 4 5 17 When all settings are completed press EXIT KEY to return measuring screen 4 5 18 The descriptions about SD CARD memory space A Use Size To show the space data numbers that have been used Free Size To show the data numbers of balance space C Total Size To show the data numbers of total space D Typical SD CARD and SDHC both can be used with the instrument except the SD CARD memory size is less than 32MB 4 5 19 RESET KEY Press this key to reboot the instrument 45 5 MEASURING PROCEDURES 5 1 10 2W one phase by two wires measurement A Diagram SCREEN 1 5 1 102W B Operation Instructions B 1 Power on the instrument by pressing POWER KEY and then press 10 KEY to select the 1 2W system the selected name of system will be appeared on bottom left display of screen 2 B 2 Connect the line voltage L1 Vn Neutral to V1 and N terminals of the instrument B 3 Place the conductor of CP 1201 A1 to A1 as screen 1 B 4 Co
14. TL88 4AC 1 Set 4 PCs Clamp Probe LCP 1201 3 PCs to DC 9V adapter 1 PC SD card 2 G 1 Carrying 1 PC Optional 2000 Amp current probe LCP 2000 Accessories 200 Amp current probe LCP 200 Flexible 3000 Amp current probe LCP 3000 USB Cable LUSB 01 RS232 cable LUPCB 02 Data Acquisition software 2 2 Electrical Specifications Phase to neutral line ACV Range Resolution Accuracy 10 0V to 600 0V 0 1V 0 5 0 5V 10 0V to 600 0V Phase to phase Resolution Accuracy 20A 0 001A lt 204 0 5 0 1 0 01A 10A 200A 0 01A lt 1004 0 5 0 5 2 100A 1200A lt 1000 A 0 5 5 1A 1000A Power factor Resolution Accuracy 0 00 to 1 00 0 01 0 04 Remark PFH Long term power factor 5 For 4W PF1 2 3 For PF2 1 2 2 Phase angle j Range Resolution Accuracy 180 to 180 0 1 19 A4coOS PF Frequency Resolution Accuracy 45 to 65 Hz 0 1 Hz 0 1 Hz Active Real Power Resolution Accuracy 0 000 to 9 999 KW 0 001 0 01 0 1 KW 1 0 008KW 10 00 to 99 99 KW 0 01 0 1 KW 1 0 08KW 100 0 to
15. again will return to screen 1 then press W to enter next setting function CT BEEP 27 screen 1 4 5 7 Folder Name WTAO1 File Name 3P401001 XLS REC Date 2008 11 28 00 03 17 Sampling Time 2 Trans Ref 220 0 V Delete File 0 SDVP 10 0 Decimal Basic 388 KB Type 1201 Free Size 1946MB Range 200A Total Size 1946MB V Range 200mV RS232 Out Sel Vi P1 51 091 1 FREQ Month Date Hour Minute Second 13 14 37 25 screen 2 4 5 7 Folder Name WTAO1 File Name 3P401001 XLS REC Date 2008 11 28 00 03 17 Sampling Time 2 Trans Ref 220 0 V Delete File 0 SDVP 10 0 Decimal Basic 388 KB Clamp Type 1201 1946MB Range 200A 1946MB V Range 200mV RS232 Out Sel Vi P1 51 091 1 p FREQ 1 1 1 1 Month Date Hour Minute Second 13 14 37 25 28 4 5 8 Beep Control the buzzer to ON OFF A When press SHIFT KEY once the symbol SHIFT1 will disappear as screen 2 at this time press or W to control the buzzer to ON OFF Press SHIFT KEY once again will return to screen 1 then press W to enter next setting function BEEP Trans Ref type screen 1 4 5 8 Folder Name WTAO1 File Name 3P401001 XLS REC Date 2008 11 28 00 03 17 Sampling Time 2 Trans Ref 220 0 V Delete File 0 SDVP 10 0 Decimal Basic 388 KB CP1201 1946MB Range 200A 1946MB V Range 200mV RS232 Out Sel
16. disappeared and show as screen 2 at this time press or to select V range to 200mV 300mV 500 1V 2V The setting function only available for the Other clamp The V range value of CP 200 CP 1201 CP 2000 CP 3000 will to 200mV it can not be adjusted B Press SHIFT KEY once again will return to screen 1 then press W to enter next setting function A Range RS232 OUT SEL 38 screen 1 4 5 14 Folder Name WTAO1 File Name 3P401001 XLS REC Date 2008 11 28 00 03 17 Sampling Time 2 Trans Ref 220 0 V Delete File 0 SDVP 10 0 Decimal Basic 388 KB Type 1201 Free Size 1946 MB 200 Total Size 1946 MB 200 TI Out Sel Vi Il P1 51 091 1 FREQ Month Date Hour Minute Second 13 14 37 25 screen 2 4 5 14 Folder Name WTAO1 File Name 3P401001 XLS REC Date 2008 11 28 00 03 17 Sampling Time 2 Trans Ref 220 0 V Delete File 0 SDVP 10 0 Decimal Basic 388 CP1201 1946MB Range 200A 1946 MB 200mV RS232 Out Sel Vi 1 51 01 1 1 1 1 1 ON FREQ Month Date Hour Minute Second 13 14 37 25 39 4 5 15 RS232 Out Sel setting A When press SHIFT KEY continuously at least two seconds as screen 2 and now press A or to select the item that intend to output maximum up to nine items when the cursor stops on the selected item and then press SETUP KEY again the selecte
17. the clamp type to Lutron Clamp or other Clamp When press SHIFT KEY once the symbol SHIFT1 will be disappeared and show as screen 2 at this time press A or V to select the Lutron standard clamp or other Clamp CP 200 CP 1201 CP 2000 CP 3000 Other B When select the different Clamp type the V range and the A range will show the corresponding value C Press SHIFT KEY once again will return to screen 1 then press W to enter next setting function Clamp Type A range 35 screen 1 4 5 12 Folder Name WTAO1 File Name 3P401001 XLS REC Date 2008 11 28 00 03 17 Sampling Time 2 Trans Ref 220 0 V Delete File 0 SDVP 10 0 Decimal Basic 388 KB CP1201 Free Size 1946MB Range 200A Total Size 1946MB V Range 200mV RS232 Out Sel Vi P1 S1 Q1 PF1 ON FREQ Month Date Hour Minute Second 13 14 37 25 screen 2 4 5 12 Folder Name WTAO1 File Name 3P401001 XLS REC Date 2008 11 28 00 03 17 Sampling Time 2 Trans Ref 220 0 V Delete File 0 SDVP 10 0 Decimal Basic 388 CP1201 1946MB Range 200A 1946MB V Range 200mV RS232 Out Sel Vi P1 Si 091 PF1 ON FREQ 1 1 1 1 Month Date Hour Minute Second 13 14 37 25 36 4 5 13 A range Setting Current range Setting When press SHIFT KEY once the symbol SHIFT1 will be disappeared and show as screen 2 at this time press or to select A ra
18. 0 000KVAR 48 5 3 30 3W three phases by three wires measurement A Diagram screen 1 5 3 303W B Operation Instructions B 1 Power on the instrument by pressing POWER KEY and then press 1 KEY to select the 3W system the selected name of system will be appeared on bottom left display of screen 2 B 2 Connect the line voltage L1 L2 and L3 to V1 V2 and V3 terminals of the instrument B 3 Place the conductor of CP 1201 A1 CP 1201 A2 CP 1201 A3 hook to A1 A2 A3 as screen 1 B 4 Connect the outputs of clamp meter CP 1201 A1 CP 1201 A2 CP 1201 A3 to A1 A2 A3 terminals of the instrument B 5 The related measuring factors will be appeared on display about the instruction of factor please refer appendix 1 5 16 page 68 49 0 000 KW 0 000 KVA 0 000 KVAR 0 000 KVAH 50 0 Hz 5 4 30 4W three phases by four wires measurement A Diagram 304W p screen 1 5 4 50 B Operation Instructions B 1 Power on the instrument by pressing POWER KEY and then press 1 KEY to select the 4W system the selected name of system will be appeared on bottom left display of screen 2 B 2 Connect the line voltage L1 L2 L3 and Vn to V1
19. 0th order Simultaneous display of Harmonics and Wave form Display of Waveform with Peak Values Analysis of Total Harmonic Distortion THD Graphic Phase diagram with 3 Phase system parameters 3 phase Voltage or Current Unbalanced Ratio VUR AUR and Unbalanced Factor Calculated Unbalanced Current through Neutral Line An Capture Transient events including Dip Swell and Outage with programmable threshold Programmable CT ratio 1 to 600 and PT ratio 1 to 1000 ACV input impedance is 10 Mega ohms Safety Standard 1010 600V Built in clock and Calendar real time data record with SD memory card sampling time set from 2 to 7200 seconds Just slot in the SD card into the computer it can down load the all the measured value with the time information year month data hour minute second to the Excel directly then user can make the further data analysis by themselves Powered by AA UM 3 DC 1 5 V X 8 batteries Alkaline type or DC 9V adapter Computer data output can cooperate with optional USB Cable LUSB 01 RS232 cable LUPCB 02 and Data Acquisition software Optional current probes LCP 1201 LCP 2000 LCP 200 LCP 3000 detail specification User can order the meter only without the current probes with the special request as intend to cooperate their own current probes Patented 2 SPECIFICATIONS 2 1 General Specifications Circuit
20. 37 25 3P401001 XLS 2008 11 28 00 03 17 i 2 Trans Ref SDVP 1096 Decimal Basic Clamp Type CP1201 A Range 200A V Range 200mV RS232 Out Sel I1 P1 S1 Q1 PF1 FREQ Date Hour Minute Second 13 14 37 25 4 5 4 Delete File Delete the files for SD A The indicator Y or N will appear on right side display of the option while pressing SHIFT KEY continuously at least two seconds and now press A the display will show Y in highlight as screen 2 press SETUP KEY again to confirm the selected file ex 3P401001 XLS will be erased then return to screen 1 or else press SETUP KEY in Y or N option to return to screen 1 Press W in screen 1 to enter next setting function Delete File SD Format screen 1 4 5 4 Folder Name WTAO1 File Name 3P401001 XLS REC Date 2008 11 28 00 03 17 Sampling Time 2 Trans Ref 220 0 V Delete File 0 SDVP 10 0 Decimal Basic 388 KB CP1201 Free Size 1946MB Range 200A Total Size 1946 MB V Range 200mV RS232 Out Sel Vi 1 1 1 51 01 PF1 ON FREQ Month Date Hour Minute Second 13 14 37 25 23 screen 2 4 5 4 Folder Name WTAO1 File Name 3P401001 XLS REC Date 2008 11 28 00 03 17 Sampling Time 2 Trans Ref 220 0 V DICHA OR N SDVP 1096 Decimal Basic 388 KB Type 1201 Free Size 1946MB Range 200A Total Size 1946MB V Range 200mV RS232 Out Sel Vi P1 Si 01
21. 73 H40 84 THD 74 41 85 Vpp 75 H42 86 CFV 76 H43 87 App 77 H44 88 CFA screen 5 4 5 15 RS232 OUTPUT SELECT ET An 42 screen 6 4 5 15 RS232 OUTPUT SELECT V12 12 P3 V23 V31 V2 V3 I1 I2 2 5 6 7 8 9 1 11 4 5 16 Year Month Date Hour Minute Second setting When press SHIFT KEY once the symbol SHIFT1 will disappear as screen 2 at this time press A or V to adjust expect numbers and press A or V continuously at least two seconds can skip the numbers faster Press W in screen 1 to enter next setting function Year gt Month C The settings about Month Date Date Hour Hour Minute Minute Second are same as above step A and step B 43 D In this setting function Year Minute press A or W in addition to adjust the numbers and the setting value will also be saved during the adjusting E In the function of setting second press A or V to adjust numbers at this point the number of second is at a standstill condition and then press setup key that will save setting value and also start counting function of second Folder Name WTAO1 File Name 3P401001 XLS REC Date 2008 11 28 00 03 17 Sampling Time 2 Trans Ref 220 0 V screen 1 0 SDVP 10 4 5 16 0 Decimal Basic 388 KB Type 1201 1946MB Range 200A 1946MB V Range 200mV RS232 Out Sel Vi 1
22. B 4 Connect the outputs of clamp meter CP 1201 A1 CP 1201 A2 CP 1201 A3 to A1 A2 A3 terminals of the instrument B 5 The related measuring factors will be appeared on display about the instruction of factor please refer appendix 1 5 16 page 68 52 screen 2 5 5 0 0 V H 0 00 A 0 0 V H 0 00 A 0 0 V H 0 00 A 0 000 KW 0 000 KVA 0 000 KVAR 0 000 KW 0 000 KVA 0 000 KVAR 0 000 KW 0 000 KVA 0 000 KVAR 0 000 KW 0 000 KVA 0 000 KVAR 0 00 0 00 0 00 0 00 0 00 0 09 d o 0 02 0 000 KWH 0 000 KVAH 0 0 Hz 5 6 ZERO adjustment for Watt Hour If reset the Exit key button 3 8 Fig 1 continuously and 6 seconds the measurement value of WH SH will reset to Zero value 53 5 7 Harmonic Function Measurement 1 Press Harmonic Key 3 25 Fig 1 will enter the Screen 1 2 Press V A 1 2 3 Key 3 27 Fig 1 will enter the Screen 2 3 If the wave show the distortion Press V A range Key 3 28 Fig 1 switch to VH or AH to let the wave form not existing distortion as Screen 3 Screen 4 4 Press Left Key 3 24 Fig 1 Right Key 3 26 Fig 1 will show the voltage or current Nth harmonic value Screen 1 5 7 100 0 220 3v 2 89 54 Screen 2 5 7 100 0 70 47 1 80 100 0 220 5v 1 90 Screen 4 5 7 5 73 634 3 09 5 8 Graphic Phasor Diagram 1 Press
23. Custom one chip of microprocessor LSI circuit Display LCD Size 81 4 X 61 mm 3 2 X 2 4 inch Dot Matrix LCD 320 X 240 pixels with back light Measurement V phase to phase V phase to ground A phase to ground KW KVA KVAR PF phase KW KVA KVAR PF system KWH KVAH KVARH PFH system Power factor Phase angle Frequency Harmonics display X Wire connections 1P 2W 1P 3W 3P 3W 3P AW Voltage ranges 10 ACV to 600 ACV auto range Current probe Current probe input signal volage input signal 200mV 300mV 500mV 1V 2V 3V and range Current probe input current range ACA 20 A 2004 2000A 1200 A 304 3004 3000A Meter can cooperate the universal current probe Safety IEC1010 CAT III 600 V standard ACV input 10 Mega ohms impedance Range select Auto range ACA Manual range Clamp 40 Hz to 1 KHz frequency response Spec tested 45 to 65 Hz frequency Over load ACV 720 ACV rms protection ACA 1300 ACA with clamp probe For the Clamp 1201 Over Indicator LCD display show The data save into the SD card will show 9999 999 overleap the decimal point Under Indicator LCD display show The data save into the SD card will show 9999 999 overleap the decimal point Data Hold Freeze the disp
24. EXCEL graphic screen 3 example V1 55 cU 25 gt Oe c HA wh ANS 9 97 75 EXCEL graphic screen 4 for example Al BP uu SU yo Sr er e e S S ON La EXCEL graphic screen 5 for example P1 lt M sS P a d oh ROO a E EU UE 9 The meter SD card structure already get patent or patent pending in following countries USA China Germany Japan Taiwan 76 ADDENDUM Question Can the DW 6093 be used to monitor power consumption of 3 different single phase circuits which might be all on the same phase or on different phases Answer If you have 3 different loads on 3 different phases or 3 different loads on the same phase drawing currents A1 A2 and A3 and the phase s have a common neutral return or common ground then power consumption can be monitored This usually means the currents should be drawn from a single power source the transformer Question If it can do this what settings should be used ie 3PAW or 1P3W etc Answer 3P4W R N gt gt 1 S N gt gt A2 gt gt Question Also I don t understand what the 1P3W setting is for the user manual only seems to show it monitoring 2 circuits can you please explain how this is to be used Answer Please refer page 36
25. El Unit PHASE2 Unit PHASE3 Unit Zu 0 0 0 0 Degree 0 Degree 0 Degree 0 0 0 0 Degree 0 Degree 0 Degree 4 0 0 0 0 Degree 0 Degree 0 Degree 0 0 0 0 Degree 0 Degree 0 Degree 6 0 0 0 0 Degree 0 Degree 0 Degree E 0 0 0 0 Degree 0 Degree 0 Degree 8 0 0 0 0 Degree 0 Degree 0 Degree 298 0 0 0 0 Degree 0 Degree 0 Degree 10 0 0 0 0 Degree 0 Degree 0 Degree 0 0 0 0 Degree 0 Degree 0 Degree 12 13 EXCEL data screen 6 for example Dc 4 7 2 2 sese 2 7 TT m BL BM BN BO BP BQ BR BS BT BU 1 WH Unit SH Unit QH Unit FREQ Unit 2 OKWH 0 0 0 Hz 3 KWH 0 KVARH 0 Hz 4 OKWH 0 Hz 5 OKWH 0 0 0 Hz 6 OKWH 0 Hz OKVAR 0 Hz 8 OKWH 0 KVARH 0 Hz 9 O KWH O 0 Hz 10 OKWH 0 0 0 Hz ll KWH 0 0 Hz 12 13 EXCEL graphic screen 1 for example 16 5 16 15 5 15 14 5 10 08 10 56 11 20 11 44 12 08 12 32 00 10 32 00 00 00 00 00 00 00 13 20 00 00 08 13 44 14 C e e EXCEL graphic screen 2 for example V1 95 11 00 j 02 71 00 j 30 71 00 Vic 00 02 21 00 96 21 00 3 26 21 00 80 21 00 1 02 11 00 96 01 00 3 22 01 00 80 01 00
26. GVAR Hr B8 KACA C9 TVAR EO TVAR Hr D10 Polarity 0 Positive 1 Negative D9 Decimal Point DP position from right to the left 0 No DP 1 1 DP 2 2 DP 3 3 DP D8 to 01 Display reading D1 LSD D8 MSD For example If the display reading is 1234 then D8 to D1 is 00001234 DO End Word RS232 setting Baud rate 9600 Parity No parity Data bit 8 Data bits Stop bit 1 Stop bit 71 8 Download the saving data from the SD card to the computer EXCEL software 1 After execute the Data Logger function take away the SD card out from the SD card socket 3 15 Fig 1 2 Plug in the SD card into the Computer s SD card slot if your computer build in this installation or insert the SD card into the SD card adapter then connect the SD card adapter into the computer 3 Power ON the computer and run the EXCEL software Down load the saving data file for example the file name 3P401001 XLS 1 201001 5 1P301001 XLS 3P301001 XLS from the SD card to the computer The saving data will present into the EXCEL software screen for example as following EXCEL data screens then user can use those EXCEL data to make the further Data or Graphic analysis usefully EXCEL data screen 1 for example Dc 5187 o r 5 d gt Anal 12 B 7u 8 s K21 B t D E G H I 1 K L 1 Position Date Time 12 Unit 23
27. Q Month Date Hour Minute Second 14 09 22 41 31 4 5 10 SDVP Set up upper and low limits of transient voltage detection A When press SHIFT KEY once will disappear as screen 2 at this time press A or W to adjsut the voltage 9o value to 1 to 100 Press SHIFT KEY once again will return to screen 1 then press W to enter next setting function SDVP Decimal screen 1 4 5 10 Folder Name WTAO1 File Name 3P401026 XLS REC Date NO File Sampling Time 2 Trans Ref 220 0 V Delete File 0 96 1096 0 Decimal Basic 23MB Clamp Type CP1201 Free Size 1904 200 Total Size 1927MB V Range 200mV RS232 Out Sel Vi P1 61 01 PF1 ON FREQ 1 1 1 1 Month Date Hour Minute Second 14 09 22 41 32 screen 2 4 5 10 Folder Name WTAO1 File Name 3P401026 XLS REC Date NO File Sampling Time 2 Trans Ref 220 0 V Delete File 0 96 1096 0 90 Basic 23 Clamp Type CP1201 Free Size 1904MB Range 200A Total Size 1927MB V Range 200mV RS232 Out Sel Vi P1 51 Ql PF1 ON FREQ 1 1 Tos Month Date Hour Minute Second 12 14 09 22 41 4 5 11 Decimal Type set the Decimal type to Basic or Euro The numerical data structure of SD card is default used as the decimal for example 20 6 1000 53 But in certain countries Europe is used as the decimal point for example 20 6 1000 53 Under s
28. R 0 000 KW 0 000 KVA 0 000 KVAR 0 000 KW 0 000 KVA 0 000 KVAR 0 00 0 00 0 00 0 0 0 000 KWH 0 000 KVAH 0 000 KVARH 0 0 Hz 67 5 16 Appendix 1 V12 V23 V31 Line Voltage V1 V2 V3 Phase Voltage A1 A2 A3 Line Current P1 P2 P3 True Power of each phase W S1 S2 S3 Apparent Power of each phase VA Q1 Q2 Q3 Reactive Power of each phase VAR P Total True Power W S2 Total Apparent Power VA Q2 Total Reactive Power VAR PF1 PF2 PF3 Power Factor of each phase Total Power Factor PFH Long Term Average Power Factor WH SH o 2 Phase Angle of each phase WH Watt Hour SH Apparent Power Hour QH Reactive Power Hour 1 2W One phase by two wires 1 3W One phase by three wires Three phases by three wires 4W Three phases by four wires SEC The sampling time of data logger CT Current transformer PT Potential transformer 68 6 MAINTENANCE Caution Remove test leads before opening the battery cover or housing case 6 1 Cleaning Caution Cleaning Only use the dry cloth to clean the plastic case 6 2 Replacement of batteries 1 When Display show the LOWBAT indicator ref 5 15 page 67 it should change the batteries 2 open the Battery Cover 3 19 Fig 1 away from the instru
29. Unit Unit 1 Unit 5 0 2009114 08 58 53 0 0 0 0 0 3 0 2009 1714 08 58 55 0 0 0 0 0 4 0 2009 1 14 08 58 57 0 0 0 ACV 0 0 B 0 2009 1114 08 58 59 0 0 0 0 0 6 0 2009 1 14 08 59 01 0 0 0 0 0 7 0 2009114 08 59 03 0 0 0 0 0 8 0 2009 1 14 08 59 05 0 0 0 0 0 9 0 2009 1114 08 59 07 0 0 0 0 0 10 0 2009 1 14 08 59 09 0 0 0 0 0 11 0 2009 1 14 08 59 11 0 ACV 0 ACV 0 0 0 72 EXCEL data screen 2 for example o amp r 2 c vise 2 N PENIS RENI NES wie ES EE 1 3 Unit Al Unit A2 Unit A3 Unit Unit P2 Unit EN 0 ACV 0 ACA 0 ACA 0 ACA 3 0 ACV 0 ACA 0 ACA 0 ACA 4 0 0 0 0 5 0 ACV 0 ACA 0 ACA 0 ACA 6 0 0 0 0 7 0 0 ACA 0 ACA 0 8 0 0 0 0 9 0 0 ACA 0 ACA 0 10 0 ACV 0 ACA 0 ACA 0 ACA 0 0 ACA 0 ACA 0 ACA 12 13 EXCEL data screen 3 for example 588 o 2 wee 12 7 u E amp E E 8
30. V2 V3 and N terminals of the instrument B 3 Place the conductor of CP 1201 A1 CP 1201 A2 CP 1201 A3 hook to A1 A2 A3 as screen 1 B 4 Connect the outputs of clamp meter CP 1201 A1 CP 1201 A2 CP 1201 A3 to A1 A2 terminals of the instrument B 5 The related measuring factors will be appeared on display about the instruction of factor please refer appendix 1 5 16 page 68 screen 2 5 4 0 00 A 0 00 A 0 00 A 0 000 KW 0 000 KVA 0 000 KVAR 0 000 KW 0 000 KVA 0 000 KVAR 0 000 KW 0 000 KVA 0 000 KVAR 0 000 KW 0 000 KVA 0 000 KVAR 0 00 0 00 0 00 0 00 0 02 0 000 KVAH 0 0 Hz 51 5 5 The CT and PT measurement A Diagram screen 1 5 5 CT PT AM ge 5 m Mf 0 2 s 5 zi f e 7 Jerr 7 7 ril ced ax d nas Ter B B Operation Instructions B 1 Power on the instrument by pressing POWER KEY and then press 10 KEY to select the 4W system the selected name of system will be appeared on bottom left display of screen 2 B 2 Connect the line voltage L1 L2 L3 and Vn to V1 V2 N3 and N terminals of the instrument B 3 Place the conductor of CP 1201 A1 CP 1201 A2 CP 1201 A3 hook to A1 A2 A3 as screen 1
31. active Power Hour Range Resolution Accuracy 0 000 to 9 999 KVARH 0 001 KVARH 2 0 008 KVARH 10 00 to 99 99 KVARH 0 01 KVARH 2 0 08 KVARH 100 0 to 999 9 KVARH 0 1 KVARH 2 0 8 KVARH 1 000 to 9 999 MVARH 0 001 MVARH 2 0 008 MVARH Harmonics of AC voltage in Magnitude Fundamental frequency 50 Hz 60 Hz Range Resolution Accuracy 1 to 20th 200 0 5 21 to 30th 0 1V 4 0 5 31 to 50th reference Harmonics of AC voltage in Percentage Fundamental frequency 50 Hz 60 Hz Range Resolution Accuracy 1 to 20th 2 104 21 to 30th 0 1 90 4 20d 31 to 50th reference Harmonics of AC current in Magnitude Fundamental frequency 50 Hz 60 Hz Range Resolution Accuracy 1 to 20th 2 054 21 to 30th 0 1A 4 0 5 31 to 50th reference Harmonics of AC current in Percentage Fundamental frequency 50 Hz 60 Hz Range Resolution Accuracy 1 to 20th 2 104 21 to 30th 0 1 90 4 20d 31 to 50th reference Peak value of ACV or ACA Sample Time _ 50 Hz 19 us 5 308 60 Hz 16 us US micro seconds Crest Factor of ACV or ACA j Range Resolution Accuracy 1 000 9 999 0 001 5 0 3 Total Harmonic Distortion R
32. ange Resolution Accuracy 0 to 20 90 20 1 to 100 90 0 1 90 296 5d 6964 104 3 FRONT PANEL DESCRIPTION 3 146 Fig 1 10 3 1 Display 3 2 10 Phase wire key button 3 3 A key button 3 4 W key button 3 5 Hold key button 3 6 Backlight key button 3 7 Power key button 3 8 Exit key button 3 9 REC key button 3 10 A current range key button 3 11 Shift key button 3 12 Setup key button 3 13 Voltage input terminals 3 14A Current probe signal input sockets 3 14B Current probe power sockets 3 15 SD card socket 3 16 RS232 socket 3 17 Reset button 3 18 DC 9V power adapter socket 3 19 Battery Cover Battery compartment 3 20 Stand 3 21 Current Sense Jaw 3 22 Trigger 3 23A Current probe signal plugs 3 23B Current probe power plug 3 24 Harmonic Analysis Left Key 3 25 Harmonic Key 3 26 Harmonic Analysis Right Key 3 27 Harmonic Analysis V1 V2 V3 1 2 Select Key 3 28 Harmonic Function Voltage or Current Input Range 3 29 Power Measurement Key 3 30 Phase Diagram Key 3 31 Waveform of Voltage and Current Key 3 32 Transient Key 4 MEASURING PREPARATION 4 1 The original screen Power Analyzer Initializing 25 4 2 Entry the measurement Screen 1 The bottom r
33. d item will be displayed in highlight B Press SHIFT KEY it can change the screen page from Screen 2 Screen 5 C If the selected items are over nine the low right display will show indicator full as screen 6 D After the selecting is completed press SHIFT KEY continuously at least two seconds again will return to screen 1 and show all the selected items at the same time Press W in screen 1 to enter next setting function RS232 Out Sel Year screen 1 4 5 15 Folder Name WTAO1 File Name 3P401001 XLS REC Date 2008 11 28 00 03 17 Sampling Time 2 Trans Ref 220 0 V Delete File 0 SDVP 10 0 Decimal Basic 388 KB Clamp Type 1201 Free Size 1946MB Range 200A Total Size 1946 MB V Range 200mV Vi P1 Si 01 1 FREQ 1 1 1 1 Month Date Hour Minute Second 13 14 37 25 40 screen 2 4 5 15 RS232 OUTPUT SELECT V12 12 P3 V23 13 v31 14 Vi 15 S2 V2 16 S3 V3 17 52 18 12 19 02 13 20 03 my 21 QZ P2 22 ue eo ML NE screen 3 4 5 15 RS232 OUTPUT SELECT 45 H12 35 H02 46 H13 36 H03 47 H14 37 H04 48 H15 38 H05 49 H16 39 H06 50 H17 40 H07 51 H18 41 H08 52 H19 42 9 53 H20 43 H11 54 H21 44 H01 55 H22 41 screen 4 4 5 15 RS232 OUTPUT SELECT 34 78 H45 68 H35 79 H46 69 H36 80 H47 70 H37 81 H48 71 H38 82 H49 72 H39 83 H50
34. e press A or W can adjust to expect PT values the adjusting numbers are from 1 to 1000 Remark When press 4 or gt 2 sec the setting no Will change fast B Press SHIFT KEY once again will return to screen 1 then press W to enter next setting function PT CT screen 1 4 5 6 Folder Name WTAO1 File Name 3P401001 XLS REC Date 2008 11 28 00 03 17 Sampling Time 2 Trans Ref 220 0 V 0 SDVP 10 0 Decimal Basic 388 KB Type 1201 Free Size 1946MB Range 200A Total Size 1946MB V Range 200mV RS232 Out Sel 1 1 Vi It 1 1 S1 Qi PFI ON FREQ Month Date Hour Minute Second 13 14 37 25 26 screen 2 4 5 6 Folder Name WTAO1 File Name 3P401001 XLS REC Date 2008 11 28 00 03 17 Sampling Time 2 Trans Ref 220 0 V 0 SDVP 10 0 Decimal Basic 388 KB Type CP1201 Free Size 1946MB Range 200A Total Size 1946 MB V Range 200mV RS232 Out Sel 1 1 Vi P1 111 Si Qi 1 FREQ Month Date Hour Minute Second 13 14 37 25 4 5 7 CT Set the Current Transformer When press SHIFT KEY once the symbol SHIFT1 will disappear as screen 2 at this time press A or W can adjust to expect CT values the adjusting numbers are from 1 to 600 Remark When press 4 or gt 2 sec the setting no Will change fast B Press SHIFT KEY once again will return to screen 1 then press W to enter next setting function CT BEEP
35. ess the key to move the cursor up in setting screen 11 DOWN W KEY 3 4 Fig 1 Press the key to move the cursor down in setting screen 12 Harmonic Analysis Left Key 3 24 Fig 1 13 Harmonic Key 3 25 Fig 1 14 Harmonic Analysis Right Key 3 26 Fig 1 15 Harmonic Analysis V1 V2 V3 1 2 Select Key 3 27 Fig 1 16 Harmonic Function Voltage or Current Input Range Select Key 3 28 Fig 1 17 Power Measurement Key 3 29 Fig 1 18 Phase Diagram Key 3 30 Fig 1 19 Waveform of Voltage and Current Key 3 31 Fig 1 20 Transient Key 3 32 Fig 1 15 4 4 SETUP KEY description 4 4 1 SHIFT KEY SHIFT 1 When the symbols SETUP and SHIFT 1 are appeared on up right display of screen 1 in the meantime and then use the A or to select the expect item SHIFT 2 When the symbols SETUP SHIFT 2 are appeared on up right display of screen 2 in the meantime and then use the A or to select 1P 2W 1P 3W 3P 3W 3P 4W in File Name function Folder Name WTAO1 3P401001 XLS 008 11 28 00 03 17 2 Trans Ref 220 0 V 0 SDVP 10 0 Decimal Basic 388 KB Clamp 1201 1946 Range 200A screen 1 4 4 1946 MB Range 200mV RS232 Sel 1 1 P1 1 1 oi PF1 FREQ Date Hour Minute Second 13 14 25 Trans Ref 220 0 V 0 96 SDVP 10 0 96 Decimal Basic 388 KB Clamp 1201 1946 Range 200A 1946 MB V Ran
36. g 1 will enter to Voltage Waveform screen as Screen 1 then Press 10 3 Key 3 2 Fig 1 once in sequence will switch the Voltage waveform from V1 to V2 V3 2 Press Waveform Key 3 31 Fig 1 once again will enter to Current Waveform screen as Screen 2 then 10 30 Key 3 2 Fig 1 once in sequence will switch the Current waveform from A1 to A2 A3 3 Press Waveform Key 3 31 Fig 1 once again will enter to Voltage Current Waveform screen as Screen 3 then press 10 Key 3 2 Fig 1 once in sequence will switch the Voltage Current waveform from V1 A1 to V2 A2 58 Screen 1 5 9 59 Screen 3 5 9 5 10 Transient Capture Dips Swells Outage 1 If intend to make the Transient Capture measurement it should set the transient voltage level high level low level at first the setting procedures please refere to chapter 4 5 9 and chapter 4 5 10 2 Press Transient Key 3 32 Fig 1 will enter to Transient Capture screen insert the SD memory card then press the REC Button 3 9 Fig 1 will make the measuremnt refer as the Screen 1 3 Definition a SWELL Vrms gt Vref Vref SDVP b DIP Vrms lt Vref Vref SDVP c OUTAGE Vrms lt 30 V to 40 V 60 d Line item V is the code show the all phase V1 V2 V3 ever happen the transient event V1 V2 V3 is the code that show each phase V1 V2 V3 ever happen t
37. ge 200mV RS232 Out Sel 1 1 Vi I1 P1 1 1 51 Qi PFi FREQ Date Hour Minute Second 13 14 37 25 4 4 2 The Setting Function menu Folder Name Set the expect folder name for SD CARD the range is between WTAO1 and WTA10 File Name Set the file name for SD CARD It allows setting 50 filenames in this function REC Date Show the recorded time of existing files Year Month Date Hour Min Sec Sampling Time Set the sampling time from 2 to 7200 seconds Delete File To delete the existing data from SD CARD SD Format to Format SD CARD fast PT Set the potential transformer from 1 to 1000 CT Set the current transformer from 1 to 600 Beep Set to ON OFF for buzzer Clamp Type Select the Clamp Type to CP 1201 CP 200 CP 2000 CP 3000 or Other Type RS232 out Sel Set RS232 output function maximum up to nine items can be selected to output screen 1 screen 2 Year Set the year Month Set the month Date Set the date Hour Set the hour Minute Set the minute Second Set the second 4 5 Setting function description before measuring Press SETUP KEY to enter setting function screen the selected item will be displayed in highlight 17 4 5 1 Folder Name Set the folder name for SD screen 1 4 5 1 Folder Name File Name 3P401001 XLS REC Date 2008 11 28 00 03 17 Sampling Time 2 Trans Ref 220 0 V 0 SDVP 10 0 Decimal Basic
38. he transient event Refer to Screen 2 4 Press the REC Button will exit the Transient Capture function as Screen 3 5 screen can show 13 transient events One file can record 99 transient events When the transient even more than 13 no then press the W Button A Button can show more transient events If the transient events less than 13 no W Button Button disable Screen 1 5 10 12018 244 Remark When press Button 3 2 Fig 1 once in insequence can switch to the the transient measurement of different Wire connections such as 1P2W 1P3W 3P3W 3P4W 61 Screen 2 5 10 z g 2011 03 01 2011 03 01 2011 03 01 2011 03 01 2011 03 01 2011 03 01 2011 03 01 2011 03 01 10 12 10 10 13 21 10 13 21 10 13 22 10 13 30 10 13 41 10 13 41 10 13 43 DIP OUTAGE SWELL DIP DIP OUTAGE DIP OUT AGE DIP DIP OUTAGE SWELL LPL2DIBHEF 7770 1 2004835 4 He oe 62 5 11 Data Logger Function A Press REC KEY once to start the data record function A 1 If the bottom right shows as Change Card it indicates the memory space is already full either or the SD CARD exist some wrong A 2 If the SD CARD is normal the data logger function will start to be executed 0 00 A 0 00 A 0 00 A 0 000 KW 0 000 KVA 0 000 KVAR 0 000 KW 0 000 KVA 0 000 KVAR 0 000 KW 0 000 KVA 0 000 KVAR 0 000 KW
39. ight display of screen 1 will show as SD Check along with blinking while inserting SD CARD then disappears after several seconds that indicates the data from SD CARD has been read completed 2 The bottom right display of screen 2 will show as NO DISK along with blinking when SD CARD is not inserted 13 screen 1 4 2 0 000KVA 0 000 KVAR 0 000KVA 0 000 KVAR 0 000KVA 0 000 KVAR 0 000 KVAR 0 00 0 02 0 000 KWH 0 000KVAH 0 000 KVARH 0 000KVA 0 000 KVAR 0 000KVA 0 000 KVAR 0 000KVA 0 000 KVAR 0 000 KVAR 0 00 0 02 0 000 KWH 0 000KVAH 0 000 KVARH 4 3 The summary description of keyboard 1 POWER KEY 3 7 Fig 1 Press the key to turn the instrument ON OFF 2 1 phase wire KEY 3 2 Fig 1 Press the key to select 1P 2W 1P 3W 3P 3W 3P AW measurement function mode 3 current RANGE KEY 3 10 Fig 1 Press the key to change the current range quickly 4 REC KEY 3 9 Fig 1 The data record key for SD CARD 5 HOLD KEY 3 5 Fig 1 Press the key to freeze the display reading 6 BACKLIGHT KEY 3 6 Fig 1 Press the key to switch LCD backlight to ON OFF 7 SETUP KEY 3 12 Fig 1 Press the key to setup the function before measuring 8 EXIT KEY 3 8 Fig 1 Press the key to exit setting screen 9 SHIFT KEY 3 11 Fig 1 Press the key to set the different functions in setting screen 10 UP A KEY 3 3 Fig 1 Pr
40. ions 5 3 FRONT PANEL 10 4 MEASURING PREPARATION 13 4 1 The original screen esses 13 4 2 Entry the measurement 5 13 4 3 The summary description of keyboard 15 4 4 SETUP KEY 2 2 2 16 4 5 Setting function description before measuring 17 5 MEASURING PROCEDURES eren 46 5 1 1 2W one phase by two wires 1 46 5 2 1 3W one phase by three wires Measurement na pr Erde etas 47 5 3 3W three phase by three wires measurement ossis esee ends 49 5 4 4W three phase by four wires measurement oy eels 50 5 5 The and 52 5 6 ZERO adjustment for Watt Hour 53 5 7 Harmonic Function Measurement 54 5 8 Graphic Phasor 56 5 9 Voltage Current 58 5 10 Transient Capture Dips Swells Outage 60 5 11 Data Logger 63 5 12 Data Hold 65 5 13 Backlight
41. lay reading Data Record SD Card Record Sampling Time Approx 1 second Power ON OFF Manual OFF by push button Real time Real time data logger saved the data data logger into SD memory card and down load the all the measured value with the time information year month data hour minute second down load to the Excel ntegration time for data logger 2 seconds to 7200 seconds the during of setting step are 2 seconds Data Output RS232 computer serial interface USB RS232 Connect the optional USB cable Computer LUSB 01 will get the USB plug interface Connect the optional RS232 cable LUPCB 02 will get the RS232 plug Operating 0 to 50 C 32 to 122 F Temperature Operating Less than 80 R H Humidity Power Supply DC 1 5V AA UM 3 Battery X 8 PCs Alkaline or heavy duty battery AC to DC 9V power adapter Power Meter 270 DCmA Consumption Clamp 22 DCmA Clamp max 50 mm 2 0 inch Dia conductor Size For the Clamp LCP 1201 Weight Meter 1010g includes batteries Clamp includded cable 500g Dimension Meter 225 X 125 X 64 mm 8 86 X 4 92 X 2 52 inch Clamp 210 X 64 X 33mm 8 3X2 5 X 1 3 inch Clamp Jaw 86 mm 3 4 inch outside Accessories Instruction manual 1 PC Included Test Leads 188 4 1 Set 4 PCs Alligator clips
42. ment and remove the battery 3 Replace with batteries DC 1 5V AA UM 3 battery X 8 PCs and reinstate the cover When install the batteries should make attention the battery polarity 4 Make sure the battery cover is secured after changing the batteries 69 7 RS232 PC SERIAL OUTPUT The instrument is provided an 3 5 mm dia phone socket 3 16 Fig 1 for RS232 computer interface socket The connector output is a 16 digits data stream which can be utilized to the user s specific application A RS232 lead with the following connection will be required to link the instrument with the PC serial input Meter PC 3 5 mm jack plug 9W D Connector Center uiii accu pa eda En Pin 4 Ground shield Pin 2 2 2K resister Pin 5 The 16 digits data stream will be displayed in the following format D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 DO 70 Each digit indicate the following status D15 Start Word D14 4 D13 1 012 amp D11 JAnnunciator for Display 03 96 B9 0 MW Hr 31 HZ MW 1 GW Hr 32 DEGREE Ci GW D2 TW Hr 48 K WATT C2 TW D3 KVA Hr 50 ACV C3 MVA D4 MVA Hr 52 ACA C4 GVA D5 GVA Hr 64 KVA C5 TVA D6 TVA Hr 65 KW HR C6 KVAR D7 KVAR Hr B6 KACV C7 MVAR D8 MVAR Hr B7 MACV C8 GVAR D9
43. nge to 20A to 20004 30A to 3000 The setting value should accoding your Clamp type The CP 3000 clamp can set 30A 300A 3000A The CP 2000 clamp set 20A 200A 2000A The CP 1201 clamp can set 20A 200A 1200A The CP 200 clamp can set 20A 200A The Other clamp can set 20A 200A 2000 30 300A 3000A Attention The meter s A range Current range value should same as the Clamp s current selecting range value Press SHIFT KEY once again will return to screen 1 then press W to enter next setting function A Range V range screen 1 4 5 13 Folder _ WTAO1 File Name 3P401001 XLS REC Date 2008 11 28 00 03 17 Sampling Time 2 Trans Ref 220 0 V Delete File 0 SDVP 10 0 Decimal Basic ize 388 KB CP1201 Free Size 1946 MB 200A Total Size 1946MB V Range 200mV RS232 Out Sel Vi P1 51 Qi ON FREQ 1 1 1 1 Month Date Minute Second 13 14 37 25 screen 2 4 5 13 Folder Name WTAO1 File Name 3P401001 XLS REC Date 2008 11 28 00 03 17 Sampling Time 2 Trans Ref 220 0 V 0 SDVP 10 0 Decimal Basic 388 KB 1201 1946 MB 200A 1946MB V Range 200mV RS232 Out Sel 1 1 Vi P1 1 14 Si 01 PF1 FREQ Month Date Hour Minute Second 11 13 14 37 25 4 5 14 V range Setting Voltage range Setting When press SHIFT KEY once the symbol SHIFT1 will be
44. nnect the output of clamp meter CP 1200 A1 to A1 terminal of the instrument B 5 The related measuring factors will be appeared on display about the instruction of factor please refer appendix 1 5 16 page 68 46 screen 2 5 1 0 0 V 0 00 A 0 000KW PF1 0 000KVA 0 000KVAR 1 0 000KWH 0 000KVAH 0 000KVARH FREQ 50 1 Hz 5 2 10 3W one phase by three wires measurement A Diagram screenl 5 2 103W 5 B Operation Instructions B 1 Power on the instrument by pressing POWER KEY and then press 10 KEY to select the 1 3W system the selected name of system will be appeared on bottom left display of screen 2 B 2 Connect the line voltage L1 L2 and Vn Neutral to V1 V2 and N terminals of the instrument B 3 Place the conductor of CP 1201 A1 CP 1201 A2 hook to A1 and A2 as screen 1 B 4 Connect the outputs of clamp meter CP 1201 A1 CP 1201 A2 to A1 and A2 terminals of the instrument B 5 The related measuring factors will be appeared on display about the instruction of factor please refer appendix 1 5 16 page 68 0 000KW 0 000KW 0 000KVA 0 000KVA HEO0 000 KVA 0 000 KVAR 0 00 0 00 0 0 0 02 0 000 KVAH 50 0 Hz 1 2 1 2 S S 0 000KVAR
45. s screen 4 F One by one to press SHIFT KEY to select different functions circularly WTAO1 401001 15 REC Date 2008 11 28 00 03 17 Sampling Time 2 Trans Ref 220 0 V 0 SDVP 10 0 Decimal Basic 388 KB 1201 1946MB Range 200A 1946MB V Range 200mV RS232 Out Sel Vi P1 Si 01 PF1 FREQ Date Hour Minute Second 13 14 37 25 WTAO1 3P401001 XLS 2008 11 28 00 03 17 2 Trans Ref 0 SDVP 10 0 Decimal Basic 388 KB 1201 1946MB Range 200A 1946MB V Range 200mV RS232 Out Sel Vi P1 Si 01 PF1 FREQ Month Date Hour Minute Second 13 14 37 25 1 1 1 1 1 1 1 1 4 5 3 Sampling time Set the data logger sampling time for SD A When press SHIFT KEY once the symbol SHIFT1 will disappear on up right display at this time press to adjust expect sampling time as screen 2 adjusting numbers are from 2 to 7200 seconds Remark When press or gt 2 sec the setting no will change fast The up right display will show SHIFT1 symbol while pressing SHIFT KEY again and then press W to enter next setting function Sampling Time Delete File screen 1 4 5 3 3P401001 XLS 2008 11 28 00 03 17 Trans Ref SDVP 10 Decimal Basic 388 KB Clamp Type CP1201 1946 MB A Range 200A 1946 MB V Range 200mV RS232 Out Sel 1 1 Vi I1 P1 1 1 51 Q1 PF1 FREQ Date Hour Minute Second 13 14
46. uch situation it should change the Decimal character at first A When press SHIFT KEY once the symbol SHIFT1 will disappear as screen 2 at this time press A or to select the Decimal type to Basic or Euro 33 Basic type The numerical data structure of SD card is default used the decimal for example 20 6 1000 53 Euro type The numerical data structure of SD card is default used the as the decimal for example 20 6 1000 53 B Press SHIFT KEY once again will return to screen 1 then press W to enter next setting function Decimal type Clamp type screen 1 4 5 11 Folder WTAO1 File Name 3P401001 XLS REC Date 2008 11 28 00 03 17 Sampling Time 2 Trans Ref 220 0 V 0 90 SDVP 10 0 96 Decimal Basic 388 KB CP1201 Free Size 1946MB Range 200A Total Size 1946 MB V Range 200mV RS232 Out Sel Vi P1 Si 01 1 FREQ 1 1 1 1 Month Date Hour Minute Second 13 14 37 25 34 screen 2 4 5 11 Folder Name WTAO1 File Name 3P401001 XLS REC Date 2008 11 28 00 03 17 Sampling Time 2 Trans Ref 220 0 V Delete File 0 SDVP 10 0 96 Decimal Basic 388 KB Type CP1201 Free Size 1946MB Range 200A Total Size 1946MB V Range 200mV RS232 Out Sel 111 Vi 1 1 Si Qi 1 FREQ Month Date Hour Minute Second 13 14 37 25 4 5 12 Clamp Type set