Home

Operating Guide - Beijer Electronics

image

Contents

1. Operating Guide 1 Introduction PWS6600 comes with a 5 7 STN Liquid Crystal Display and is water and dust resistant according to IP65 The PWS is CE marked and meets your need to be highly transient resistant while in operation Also its compact design makes connections with other machinery more flexible thus achieving the optimal per formance of your machines ADP is used to design applications of the PWS it is reliable user friendly and compatible with many models The latest released ADP Version 6 1 and above can be used to design applications for the PWS 2 Self Test Once the PWS is turned on it will automatically execute a self test to check its hardware The result of a self test is displayed on the LCD See below for items to check in a self test Human Machine Interface ROM BIOS Version 2 1 Copyright 2011 Display Type Mono STN LCD System RAM Size Video RAM Size Battery Backed RAM Size Application Memory Size Working RAM Test Passed Battery Status Passed BIOS ROM Checksum Passed Firmware Checksum Passed Application Checksum Passed RTC Function Test Passed Parameter Checksum Passed Communcation Port 1 Test Passed Communcation Port 2 Test Passed DIP Switches Setting 8 1 11011111 If any of tests does not pass the self test it will be noted with Failed next to the test item Additionally the message Error Press screen to continue will be displayed at the bottom
2. RS232 9 pin male 9 pin female 25 pin male 9 pin female RXD 2 2 RD __ 2 RD TXD 3 gt lt 3 sp 3 5D GND 5 5 SG 5 SG RTS 7 we 1 CD _ 1 CD CTS 8 L 4 DTR L 4 DTR 6 DSR 6 DSR 7 RTS 7 RTS L 8 CTS L 8 CTS PWS PC COM PWS PC COM Warning To avoid an electronic shock be sure to switch off the power before connecting the download cable to the PWS Set the dip switch SW7 ON After the self test the system menu will be displayed on the screen and the PWS is ready to download the application Start ADP and open the application file to be downloaded Make sure that the communication parameters are correctly configured Also remember to compile the file before downloading it The file has to be compiled every time a change has been made in the file before downloading it Then select Application Download Firmware and then Application in ADP if it is a first time to download the application to the PWS otherwise select Application Download Application The following appears on the screen while the PWS is downloading Programming application TS Link port COM1 Ee Scenario 3 Password protecting a button in the PWS The ADP can create a button which is protected by a password for execution For example a Goto Screen but ton can be designed with a high level of security which means that a password with a high level of privilege is required in order to open t
3. cation data of the PWS 6 Setting Communication Parameters There are two ways to configure working parameters to set parameters in the PWS or in ADP To set parameters in the PWS select F2 Confg in the system menu Note Remember to set the dip switch SW5 ON if parameters are set in the PWS To set parameters in ADP select Application Workstation Setup Then select the Connection tab to set com munication parameters Note Remember to set the dip switch SW5 OFF if parameters are set in ADP Touch the upper left and lower right corners of the screen Next follow the route on the screen 7 Adjusting Touch Panel l 2 3 Lastly touch the square on the center of the screen to complete the task Note Click Clear Data Ram of Set Key the data stored in RAM will be erased 12 Setting a Password Scenario 1 Requiring a password to start the PWS If the dip switch SW6 ON the user needs to enter a password to start the PWS For this purpose the designer can use the object Action Button in ADP to create a button which displays the password table on the PWS dis play A user with the right to access the table can register passwords and user levels in the table In the illustration above the TBL button is an action button used to display the password table When the but ton is selected the password table is displayed on the screen for a user with the right to access the table Touch the password to highlight an area f
4. etails on the slide out menu please see the ADP User s Manual HITECH e Menu Key T I nm uo A o lt 7 T a th o O O oF O w When a key is pressed the PWS will make a beep sound to signal that a command is pressed The default setting is a 200 ms beep and can be configured 10 Uploading Downloading a Recipe Set the dip switch SW7 ON After the self test the system menu will be displayed on the screen and the PWS is ready to upload download a recipe Uploading a Recipe Select File Upload Recipes in ADP and the Save As dialog box will appear on the screen Enter the name of a recipe file RCP to save Click Save While the PWS is uploading the recipe Uploading recipes is displayed on the screen Downloading a Recipe Open an application file with the recipe to be downloaded in ADP Select File Download Recipes to display the Open dialog Enter the name of the recipe file RCP and click Open While the PWS is downloading the recipe Downloading recipes is displayed on the screen Uploading recipes Downloading recipes Th After the download is finished select F5 Run to run the application le Remember to define the length and the number of recipes in the applicatio
5. he other screen As the button is selected and the current user has a lower privilege than has been set for the button the PWS will prompt the user for a password The user will need a password with at least the level of privilege that has been set for the button This function can restrict users to access to certain parts of the application Scenario 4 Requiring a password to copy or upload application When selecting F3 Copy in the system menu or File Upload Application in ADP the PWS will prompt for a password The user will need to enter the correct password to copy an application from one PWS to another Note that setting this password is different from the passwords set in Scenarios 1 3 To set this password select Application Workstation Setup in ADP Under the Password tab the project designer is able to set the pass word Beijer Electronics AB Beijer Electronics Corp Box 426 8F No 108 Minquan Rd Xindian Dist SE 201 24 Malm Sweden New Taipei City 23141 Taiwan R O C Tel 46 40 35 86 00 Tel 886 2 2218 3600 Fax 46 40 93 23 01 Fax 886 2 2218 9547 www beijerelectronics com www beijerelectronics com tw 07 25 2011 V 6 660018 06
6. n Also remember to upload the for mat of recipes from the PWS before starting to edit a new set of recipe data in the PC For further information about creating editing recipes please see the corresponding chapter in the ADP User s Manual 11 Copying an Application To copy an application from one PWS to another select F3 Copy from the system menu Set the dip switch SW7 ON and connect the two PWSs with a download cable After the self test the system menu will be dis played on the screen Select F3 Copy in the system menu from the PWS with the application to be copied The PWS will prompt for a password enter the password set in ADP from Application Workstation Setup Once the correct password is entered the PWS will start to copy the application between the two PWSs The following appears on the screens during the copying Copying firmware Programming firmware ee sh Link port COM1 Link port COM1 Note When copying for the first time make sure to first run the application once or else the copy function will not work 5 Bench and Function Tests Set the dip switches SW3 and SW4 OFF to be able to run the bench and function tests for the PWS Turn on the PWS and the following screen will be displayed Bench Test Function Test The bench test performs an overall hardware test and the function test lets the user select which item to be tested Note The bench test will clear the appli
7. of the screen If the power to the PWS or the PC was interrupted while downloading Firmware checksum or Application checksum will not pass the self test indicated by Failed in the self test results after power is restored If this happens the user can simply follow the download procedure to re download the application or data After downloading again all items should pass the self test 9 Uploading an Application An application can also be uploaded from the PWS to the PC Thus a user can save an application as a V6F file in ADP for future use Warning To avoid an electric shock be sure to switch off the power before connecting the communica tion cable to the PWS Make sure that the PWS and the PC are connected according to section Downloading an Application Set the dip switch SW7 ON After the self test the system menu will be displayed on the screen and the PWS is ready to upload the application Also make sure that communication parameters are correctly configured Select File Upload Application in ADP and the Save As dialog box will appear on the screen Enter a name of a firmware file AF6 to save Click Save Then the PWS will prompt for a password enter the password set in ADP from Application Work station Setup Once the correct password is entered the PWS starts to upload the application to the PC For information about setting a password please see section Setting a Password While the PWS is
8. or entering a value How to configure an Action Button is described in the ADP User s Manual After registering passwords and user levels set the dip switch SW6 ON i e password required Restart the PWS and after the self test the user will be prompted to enter a password in order to run the PWS The PWS will determine the user level from the entered password For instance if the level of the password entered by the user is 2 then the PWS will set the user level to 2 User level 1 has the highest privilege and User level 9 has the lowest Note Only users of User Level 1 has the right of access to the password table Scenario 2 Re entering a password The object Action Button in ADP also allows the designer to create a button which asks the user to re enter a password For example by pressing the PSW button the password keypad will be displayed to prompt the user to enter a password After entering the password the PWS will update the user level according to the most recent password which has been entered Therefore this button can be applied to raise or drop one s privileges while the PWS is in operation Password Keypad How to configure an Action Button is described in the ADP User s Manual 8 Downloading an Application Connect the RS232 port on the PC to the COM1 port on the PWS using a WPC P8 42 cable The connection can also be made according to the illustration below PWS COMI1 PC COM RS232 PWS COM2 PC COM
9. uploading the following is displayed Uploading firmware le Link port COM1 After uploading select File Reconstruct Source in ADP to display the Open dialog Open the uploaded appli cation file C64 or AAG The application screen will be displayed on the PC monitor Finally select File Save As to save the application as a V6F file Thus a source file can serve the purposes of maintenance and modification Note When using the PWS for the first time make sure to first run the application once or else the upload function will not work 3 System Menu Set the dip switch SW7 ON After the self test the system menu of the PWS is displayed on the screen Wait command Link port COM1 Link Contg Copy Set Run The functions of the commands are briefly explained below The PWS is connected F2 Confg Sets up the internal time clock and communication parameters in the PWS All the settings has to be made for the PWS to work properly Use A Y lt and gt to move to desired field and to set the value of the field F3 Copy Copies application data to the other same model of PWS Calibrates the touch screen adjusts LCD contrast and clears RAM data Runs the application 4 Keypad The six keys on the PWS include one menu key and five functional keys F1 F5 Press the menu key to slide out the innovative slide out menu For further d

Download Pdf Manuals

image

Related Search

Related Contents

Owner`s Manual (1)  BFC-E Manuel d`utilisation - DSI  TB2F - YBath  GEIGER-SOLIDline GEIGER  lire la suite - Rotary International District 1770  Modulo - Posturas Forzadas  Goodman Mfg SS-SSX16 User's Manual  

Copyright © All rights reserved.